1
|
Lei Y, Shu HK, Tian S, Wang T, Liu T, Mao H, Shim H, Curran WJ, Yang X. Pseudo CT Estimation using Patch-based Joint Dictionary Learning. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2018:5150-5153. [PMID: 30441499 DOI: 10.1109/embc.2018.8513475] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Magnetic resonance (MR) simulators have recently gained popularity; it avoids the unnecessary radiation exposure associated with Computed Tomography (CT) when used for radiation therapy planning. We propose a method for pseudo CT estimation from MR images based on joint dictionary learning. Patient-specific anatomical features were extracted from the aligned training images and adopted as signatures for each voxel. The most relevant and informative features were identified to train the joint dictionary learning-based model. The well-trained dictionary was used to predict the pseudo CT of a new patient. This prediction technique was validated with a clinical study of 12 patients with MR and CT images of the brain. The mean absolute error (MAE), peak signal-to-noise ratio (PSNR), normalized cross correlation (NCC) indexes were used to quantify the prediction accuracy. We compared our proposed method with a state-of-the-art dictionary learning method. Overall our proposed method significantly improves the prediction accuracy over the state-of-the-art dictionary learning method. We have investigated a novel joint dictionary Iearning- based approach to predict CT images from routine MRIs and demonstrated its reliability. This CT prediction technique could be a useful tool for MRI-based radiation treatment planning or attenuation correction for quantifying PET images for PET/MR imaging.
Collapse
|
2
|
|
3
|
Lei Y, Harms J, Wang T, Liu Y, Shu HK, Jani AB, Curran WJ, Mao H, Liu T, Yang X. MRI-only based synthetic CT generation using dense cycle consistent generative adversarial networks. Med Phys 2019; 46:3565-3581. [PMID: 31112304 DOI: 10.1002/mp.13617] [Citation(s) in RCA: 145] [Impact Index Per Article: 29.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 05/14/2019] [Accepted: 05/14/2019] [Indexed: 02/07/2023] Open
Abstract
PURPOSE Automated synthetic computed tomography (sCT) generation based on magnetic resonance imaging (MRI) images would allow for MRI-only based treatment planning in radiation therapy, eliminating the need for CT simulation and simplifying the patient treatment workflow. In this work, the authors propose a novel method for generation of sCT based on dense cycle-consistent generative adversarial networks (cycle GAN), a deep-learning based model that trains two transformation mappings (MRI to CT and CT to MRI) simultaneously. METHODS AND MATERIALS The cycle GAN-based model was developed to generate sCT images in a patch-based framework. Cycle GAN was applied to this problem because it includes an inverse transformation from CT to MRI, which helps constrain the model to learn a one-to-one mapping. Dense block-based networks were used to construct generator of cycle GAN. The network weights and variables were optimized via a gradient difference (GD) loss and a novel distance loss metric between sCT and original CT. RESULTS Leave-one-out cross-validation was performed to validate the proposed model. The mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and normalized cross correlation (NCC) indexes were used to quantify the differences between the sCT and original planning CT images. For the proposed method, the mean MAE between sCT and CT were 55.7 Hounsfield units (HU) for 24 brain cancer patients and 50.8 HU for 20 prostate cancer patients. The mean PSNR and NCC were 26.6 dB and 0.963 in the brain cases, and 24.5 dB and 0.929 in the pelvis. CONCLUSION We developed and validated a novel learning-based approach to generate CT images from routine MRIs based on dense cycle GAN model to effectively capture the relationship between the CT and MRIs. The proposed method can generate robust, high-quality sCT in minutes. The proposed method offers strong potential for supporting near real-time MRI-only treatment planning in the brain and pelvis.
Collapse
Affiliation(s)
- Yang Lei
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, USA
| | - Joseph Harms
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, USA
| | - Tonghe Wang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, USA
| | - Yingzi Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, USA
| | - Hui-Kuo Shu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, USA
| | - Ashesh B Jani
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, USA
| | - Walter J Curran
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, USA
| | - Hui Mao
- Department of Radiology and Imaging Sciences and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, USA
| | - Tian Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, USA
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, USA
| |
Collapse
|
4
|
Lei Y, Harms J, Wang T, Tian S, Zhou J, Shu HK, Zhong J, Mao H, Curran WJ, Liu T, Yang X. MRI-based synthetic CT generation using semantic random forest with iterative refinement. Phys Med Biol 2019; 64:085001. [PMID: 30818292 PMCID: PMC7778365 DOI: 10.1088/1361-6560/ab0b66] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Target delineation for radiation therapy treatment planning often benefits from magnetic resonance imaging (MRI) in addition to x-ray computed tomography (CT) due to MRI's superior soft tissue contrast. MRI-based treatment planning could reduce systematic MR-CT co-registration errors, medical cost, radiation exposure, and simplify clinical workflow. However, MRI-only based treatment planning is not widely used to date because treatment-planning systems rely on the electron density information provided by CTs to calculate dose. Additionally, air and bone regions are difficult to separategiven their similar intensities in MR imaging. The purpose of this work is to develop a learning-based method to generate patient-specific synthetic CT (sCT) from a routine anatomical MRI for use in MRI-only radiotherapy treatment planning. An auto-context model with patch-based anatomical features was integrated into a classification random forest to generate and improve semantic information. The semantic information along with anatomical features was then used to train a series of regression random forests based on the auto-context model. After training, the sCT of a new MRI can be generated by feeding anatomical features extracted from the MRI into the well-trained classification and regression random forests. The proposed algorithm was evaluated using 14 patient datasets withT1-weighted MR and corresponding CT images of the brain. The mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and normalized cross correlation (NCC) were 57.45 ± 8.45 HU, 28.33 ± 1.68 dB, and 0.97 ± 0.01. We also compared the difference between dose maps calculated on the sCT and those on the original CT, using the same plan parameters. The average DVH differences among all patients are less than 0.2 Gy for PTVs, and less than 0.02 Gy for OARs. The sCT generation by the proposed method allows for dose calculation based MR imaging alone, and may be a useful tool for MRI-based radiation treatment planning.
Collapse
Affiliation(s)
- Yang Lei
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, United States of America
| | - Joseph Harms
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, United States of America
| | - Tonghe Wang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, United States of America
| | - Sibo Tian
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, United States of America
| | - Jun Zhou
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, United States of America
| | - Hui-Kuo Shu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, United States of America
| | - Jim Zhong
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, United States of America
| | - Hui Mao
- Department of Radiology and Imaging Sciences and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, United States of America
| | - Walter J Curran
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, United States of America
| | - Tian Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, United States of America
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, United States of America
| |
Collapse
|
5
|
Shafai-Erfani G, Wang T, Lei Y, Tian S, Patel P, Jani AB, Curran WJ, Liu T, Yang X. Dose evaluation of MRI-based synthetic CT generated using a machine learning method for prostate cancer radiotherapy. Med Dosim 2019; 44:e64-e70. [PMID: 30713000 DOI: 10.1016/j.meddos.2019.01.002] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2018] [Revised: 01/07/2019] [Accepted: 01/16/2019] [Indexed: 11/24/2022]
Abstract
Magnetic resonance imaging (MRI)-only radiotherapy treatment planning is attractive since MRI provides superior soft tissue contrast over computed tomographies (CTs), without the ionizing radiation exposure. However, it requires the generation of a synthetic CT (SCT) from MRIs for patient setup and dose calculation. In this study, we aim to investigate the accuracy of dose calculation in prostate cancer radiotherapy using SCTs generated from MRIs using our learning-based method. We retrospectively investigated a total of 17 treatment plans from 10 patients, each having both planning CTs (pCT) and MRIs acquired before treatment. The SCT was registered to the pCT for generating SCT-based treatment plans. The original pCT-based plans served as ground truth. Clinically-relevant dose volume histogram (DVH) metrics were extracted from both ground truth and SCT-based plans for comparison and evaluation. Gamma analysis was performed for the comparison of absorbed dose distributions between SCT- and pCT-based plans of each patient. Gamma analysis of dose distribution on pCT and SCT within 1%/1 mm at 10% dose threshold showed greater than 99% pass rate. The average differences in DVH metrics for planning target volumes (PTVs) were less than 1%, and similar metrics for organs at risk (OAR) were not statistically different. The SCT images created from MR images using our proposed machine learning method are accurate for dose calculation in prostate cancer radiation treatment planning. This study also demonstrates the great potential for MRI to completely replace CT scans in the process of simulation and treatment planning. However, MR images are needed to further analyze geometric distortion effects. Digitally reconstructed radiograph (DRR) can be generated within our method, and their accuracy in patient setup needs further analysis.
Collapse
Affiliation(s)
- Ghazal Shafai-Erfani
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Tonghe Wang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Yang Lei
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Sibo Tian
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Pretesh Patel
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Ashesh B Jani
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Walter J Curran
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Tian Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA.
| |
Collapse
|
6
|
Lei Y, Jeong JJ, Wang T, Shu HK, Patel P, Tian S, Liu T, Shim H, Mao H, Jani AB, Curran WJ, Yang X. MRI-based pseudo CT synthesis using anatomical signature and alternating random forest with iterative refinement model. J Med Imaging (Bellingham) 2018; 5:043504. [PMID: 30840748 PMCID: PMC6280993 DOI: 10.1117/1.jmi.5.4.043504] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2018] [Accepted: 11/12/2018] [Indexed: 12/20/2022] Open
Abstract
We develop a learning-based method to generate patient-specific pseudo computed tomography (CT) from routinely acquired magnetic resonance imaging (MRI) for potential MRI-based radiotherapy treatment planning. The proposed pseudo CT (PCT) synthesis method consists of a training stage and a synthesizing stage. During the training stage, patch-based features are extracted from MRIs. Using a feature selection, the most informative features are identified as an anatomical signature to train a sequence of alternating random forests based on an iterative refinement model. During the synthesizing stage, we feed the anatomical signatures extracted from an MRI into the sequence of well-trained forests for a PCT synthesis. Our PCT was compared with original CT (ground truth) to quantitatively assess the synthesis accuracy. The mean absolute error, peak signal-to-noise ratio, and normalized cross-correlation indices were 60.87 ± 15.10 HU , 24.63 ± 1.73 dB , and 0.954 ± 0.013 for 14 patients' brain data and 29.86 ± 10.4 HU , 34.18 ± 3.31 dB , and 0.980 ± 0.025 for 12 patients' pelvic data, respectively. We have investigated a learning-based approach to synthesize CTs from routine MRIs and demonstrated its feasibility and reliability. The proposed PCT synthesis technique can be a useful tool for MRI-based radiation treatment planning.
Collapse
Affiliation(s)
- Yang Lei
- Emory University, Winship Cancer Institute, Department of Radiation Oncology, Atlanta, Georgia, United States
| | - Jiwoong Jason Jeong
- Emory University, Winship Cancer Institute, Department of Radiation Oncology, Atlanta, Georgia, United States
| | - Tonghe Wang
- Emory University, Winship Cancer Institute, Department of Radiation Oncology, Atlanta, Georgia, United States
| | - Hui-Kuo Shu
- Emory University, Winship Cancer Institute, Department of Radiation Oncology, Atlanta, Georgia, United States
| | - Pretesh Patel
- Emory University, Winship Cancer Institute, Department of Radiation Oncology, Atlanta, Georgia, United States
| | - Sibo Tian
- Emory University, Winship Cancer Institute, Department of Radiation Oncology, Atlanta, Georgia, United States
| | - Tian Liu
- Emory University, Winship Cancer Institute, Department of Radiation Oncology, Atlanta, Georgia, United States
| | - Hyunsuk Shim
- Emory University, Winship Cancer Institute, Department of Radiation Oncology, Atlanta, Georgia, United States
- Emory University, Winship Cancer Institute, Department of Radiology and Imaging Sciences, Atlanta, Georgia, United States
| | - Hui Mao
- Emory University, Winship Cancer Institute, Department of Radiology and Imaging Sciences, Atlanta, Georgia, United States
| | - Ashesh B. Jani
- Emory University, Winship Cancer Institute, Department of Radiation Oncology, Atlanta, Georgia, United States
| | - Walter J. Curran
- Emory University, Winship Cancer Institute, Department of Radiation Oncology, Atlanta, Georgia, United States
| | - Xiaofeng Yang
- Emory University, Winship Cancer Institute, Department of Radiation Oncology, Atlanta, Georgia, United States
| |
Collapse
|
7
|
Lei Y, Tang X, Higgins K, Wang T, Liu T, Dhabaan A, Shim H, Curran WJ, Yang X. Improving Image Quality of Cone-Beam CT Using Alternating Regression Forest. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2018; 10573:1057345. [PMID: 31456600 PMCID: PMC6711599 DOI: 10.1117/12.2292886] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
We propose a CBCT image quality improvement method based on anatomic signature and auto-context alternating regression forest. Patient-specific anatomical features are extracted from the aligned training images and served as signatures for each voxel. The most relevant and informative features are identified to train regression forest. The well-trained regression forest is used to correct the CBCT of a new patient. This proposed algorithm was evaluated using 10 patients' data with CBCT and CT images. The mean absolute error (MAE), peak signal-to-noise ratio (PSNR) and normalized cross correlation (NCC) indexes were used to quantify the correction accuracy of the proposed algorithm. The mean MAE, PSNR and NCC between corrected CBCT and ground truth CT were 16.66HU, 37.28dB and 0.98, which demonstrated the CBCT correction accuracy of the proposed learning-based method. We have developed a learning-based method and demonstrated that this method could significantly improve CBCT image quality. The proposed method has great potential in improving CBCT image quality to a level close to planning CT, therefore, allowing its quantitative use in CBCT-guided adaptive radiotherapy.
Collapse
Affiliation(s)
- Yang Lei
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Xiangyang Tang
- Department of Radiology and Imaging Sciences and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Kristin Higgins
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Tonghe Wang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Tian Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Anees Dhabaan
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Hyunsuk Shim
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
- Department of Radiology and Imaging Sciences and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Walter J. Curran
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| |
Collapse
|
8
|
Lei Y, Xu D, Zhou Z, Higgins K, Dong X, Liu T, Shim H, Mao H, Curran WJ, Yang X. High-resolution CT Image Retrieval Using Sparse Convolutional Neural Network. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2018; 10573:105733F. [PMID: 31456601 PMCID: PMC6711608 DOI: 10.1117/12.2292891] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
We propose a high-resolution CT image retrieval method based on sparse convolutional neural network. The proposed framework is used to train the end-to-end mapping from low-resolution to high-resolution images. The patch-wise feature of low-resolution CT is extracted and sparsely represented by a convolutional layer and a learned iterative shrinkage threshold framework, respectively. Restricted linear unit is utilized to non-linearly map the low-resolution sparse coefficients to the high-resolution ones. An adaptive high-resolution dictionary is applied to construct the informative signature which is highly connected to a high-resolution patch. Finally, we feed the signature to a convolutional layer to reconstruct the predicted high-resolution patches and average these overlapping patches to generate high-resolution CT. The loss function between reconstructed images and the corresponding ground truth high-resolution images is applied to optimize the parameters of end-to-end neural network. The well-trained map is used to generate the high-resolution CT from a new low-resolution input. This technique was tested with brain and lung CT images and the image quality was assessed using the corresponding CT images. Peak signal-to-noise ratio (PSNR), structural similarity index (SSIM) and mean absolute error (MAE) indexes were used to quantify the differences between the generated high-resolution and corresponding ground truth CT images. The experimental results showed the proposed method could enhance images resolution from low-resolution images. The proposed method has great potential in improving radiation dose calculation and delivery accuracy and decreasing CT radiation exposure of patients.
Collapse
Affiliation(s)
- Yang Lei
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Dong Xu
- Department of Ultrasound Imaging, Zhejiang Cancer Hospital, Hangzhou, China 310022
| | - Zhengyang Zhou
- Department of Radiology, Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Nanjing, China 210008
| | - Kristin Higgins
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Xue Dong
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Tian Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Hyunsuk Shim
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
- Department of Radiation Oncology and Imaging Sciences and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Hui Mao
- Department of Radiation Oncology and Imaging Sciences and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Walter J. Curran
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| |
Collapse
|