1
|
Aliotta E, Paudyal R, Diplas B, Han J, Hu YC, Hun Oh J, Hatzoglou V, Jensen N, Zhang P, Aristophanous M, Riaz N, Deasy JO, Lee NY, Shukla-Dave A. Multi-modality imaging parameters that predict rapid tumor regression in head and neck radiotherapy. Phys Imaging Radiat Oncol 2024; 31:100603. [PMID: 39040433 PMCID: PMC11261256 DOI: 10.1016/j.phro.2024.100603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 06/19/2024] [Accepted: 06/20/2024] [Indexed: 07/24/2024] Open
Abstract
Background and purpose Volume regression during radiotherapy can indicate patient-specific treatment response. We aimed to identify pre-treatment multimodality imaging (MMI) metrics from positron emission tomography (PET), magnetic resonance imaging (MRI), and computed tomography (CT) that predict rapid tumor regression during radiotherapy in human papilloma virus (HPV) associated oropharyngeal carcinoma. Materials and methods Pre-treatment FDG PET-CT, diffusion-weighted MRI (DW-MRI), and intra-treatment (at 1, 2, and 3 weeks) MRI were acquired in 72 patients undergoing chemoradiation therapy for HPV+ oropharyngeal carcinoma. Nodal gross tumor volumes were delineated on longitudinal images to measure intra-treatment volume changes. Pre-treatment PET standardized uptake value (SUV), CT Hounsfield Unit (HU), and non-gaussian intravoxel incoherent motion DW-MRI metrics were computed and correlated with volume changes. Intercorrelations between MMI metrics were also assessed using network analysis. Validation was carried out on a separate cohort (N = 64) for FDG PET-CT. Results Significant correlations with volume loss were observed for baseline FDG SUVmean (Spearman ρ = 0.46, p < 0.001), CT HUmean (ρ = 0.38, p = 0.001), and DW-MRI diffusion coefficient, Dmean (ρ = -0.39, p < 0.001). Network analysis revealed 41 intercorrelations between MMI and volume loss metrics, but SUVmean remained a statistically significant predictor of volume loss in multivariate linear regression (p = 0.01). Significant correlations were also observed for SUVmean in the validation cohort in both primary (ρ = 0.30, p = 0.02) and nodal (ρ = 0.31, p = 0.02) tumors. Conclusions Multiple pre-treatment imaging metrics were correlated with rapid nodal gross tumor volume loss during radiotherapy. FDG-PET SUV in particular exhibited significant correlations with volume regression across the two cohorts and in multivariate analysis.
Collapse
Affiliation(s)
- Eric Aliotta
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Ramesh Paudyal
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Bill Diplas
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - James Han
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Yu-Chi Hu
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Jung Hun Oh
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Vaios Hatzoglou
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Naomi Jensen
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Peng Zhang
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
| | | | - Nadeem Riaz
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Joseph O. Deasy
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Nancy Y. Lee
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Amita Shukla-Dave
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY
| |
Collapse
|
2
|
Jacobsen MC, Rigaud B, Simiele SJ, Rauch GM, Ning MS, Vedam S, Klopp AH, Stafford RJ, Brock KK, Venkatesan AM. Feasibility of quantitative diffusion-weighted imaging during intra-procedural MRI-guided brachytherapy of locally advanced cervical and vaginal cancers. Brachytherapy 2023; 22:736-745. [PMID: 37612174 DOI: 10.1016/j.brachy.2023.06.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 05/30/2023] [Accepted: 06/15/2023] [Indexed: 08/25/2023]
Abstract
PURPOSE To determine the feasibility of quantitative apparent diffusion coefficient (ADC) acquisition during magnetic resonance imaging-guided brachytherapy (MRgBT) using reduced field-of-view (rFOV) diffusion-weighted imaging (DWI). METHODS AND MATERIALS T2-weighted (T2w) MR and full-FOV single-shot echo planar (ssEPI) DWI were acquired in 7 patients with cervical or vaginal malignancy at baseline and prior to brachytherapy, while rFOV-DWI was acquired during MRgBT following brachytherapy applicator placement. The gross target volume (GTV) was contoured on the T2w images and registered to the ADC map. Voxels at the GTV's maximum Maurer distance comprised a central sub-volume (GTVcenter). Contour ADC mean and standard deviation were compared between timepoints using repeated measures ANOVA. RESULTS ssEPI-DWI mean ADC increased between baseline and prebrachytherapy from 1.03 ± 0.18 10-3 mm2/s to 1.34 ± 0.28 10-3 mm2/s for the GTV (p = 0.06) and from 0.84 ± 0.13 10-3 mm2/s to 1.26 ± 0.25 10-3 mm2/s at the level of the GTVcenter (p = 0.03), consistent with early treatment response. rFOV-DWI during MRgBT demonstrated mean ADC values of 1.28 ± 0.14 10-3 mm2/s and 1.28 ± 0.19 10-3 mm2/s for the GTV and GTVcenter, respectively (p = 0.02 and p = 0.03 relative to baseline). No significant differences were observed between ssEPI-DWI and rFOV-DWI ADC measurements. CONCLUSIONS Quantitative ADC measurement in the setting of MRI guided brachytherapy implant placement for cervical and vaginal cancers is feasible using rFOV-DWI, with comparable mean ADC comparable to prebrachytherapy ssEPI-DWI, and may enable MRI-guided radiotherapy targeting of low ADC, radiation resistant sub-volumes of tumor.
Collapse
Affiliation(s)
- Megan C Jacobsen
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX.
| | - Bastien Rigaud
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Samantha J Simiele
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Gaiane M Rauch
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Matthew S Ning
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Sastry Vedam
- University of Maryland, Department of Radiation Oncology, Baltimore, MD
| | - Ann H Klopp
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - R Jason Stafford
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Kristy K Brock
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Aradhana M Venkatesan
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX.
| |
Collapse
|
3
|
Kaanders JHAM, Bussink J, Aarntzen EHJG, Braam P, Rütten H, van der Maazen RWM, Verheij M, van den Bosch S. [18F]FDG-PET-Based Personalized Radiotherapy Dose Prescription. Semin Radiat Oncol 2023; 33:287-297. [PMID: 37331783 DOI: 10.1016/j.semradonc.2023.03.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/20/2023]
Abstract
PET imaging with 2'-deoxy-2'-[18F]fluoro-D-glucose ([18F]FDG) has become one of the pillars in the management of malignant diseases. It has proven value in diagnostic workup, treatment policy, follow-up, and as prognosticator for outcome. [18F]FDG is widely available and standards have been developed for PET acquisition protocols and quantitative analyses. More recently, [18F]FDG-PET is also starting to be appreciated as a decision aid for treatment personalization. This review focuses on the potential of [18F]FDG-PET for individualized radiotherapy dose prescription. This includes dose painting, gradient dose prescription, and [18F]FDG-PET guided response-adapted dose prescription. The current status, progress, and future expectations of these developments for various tumor types are discussed.
Collapse
Affiliation(s)
- Johannes H A M Kaanders
- Department of Radiation Oncology, Radboud university medical center, Nijmegen, The Netherlands..
| | - Johan Bussink
- Department of Radiation Oncology, Radboud university medical center, Nijmegen, The Netherlands
| | - Erik H J G Aarntzen
- Department of Medical Imaging, Radboud university medical center, Nijmegen, The Netherlands
| | - Pètra Braam
- Department of Radiation Oncology, Radboud university medical center, Nijmegen, The Netherlands
| | - Heidi Rütten
- Department of Radiation Oncology, Radboud university medical center, Nijmegen, The Netherlands
| | | | - Marcel Verheij
- Department of Radiation Oncology, Radboud university medical center, Nijmegen, The Netherlands
| | - Sven van den Bosch
- Department of Radiation Oncology, Radboud university medical center, Nijmegen, The Netherlands
| |
Collapse
|
4
|
Markus M, Sartor H, Bjurberg M, Trägårdh E. Metabolic parameters of [ 18F]FDG PET-CT before and after radiotherapy may predict survival and recurrence in cervical cancer. Acta Oncol 2023; 62:180-188. [PMID: 36815676 DOI: 10.1080/0284186x.2023.2181100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
BACKGROUND Cervical cancer is the fourth most common female malignancy. [18F]-fluorodeoxyglucose (FDG) positron emission tomography with computed tomography (PET-CT) is routinely performed in patients with locally advanced cervical cancer for staging and treatment response evaluation. With this retrospective, observational cohort study, we wanted to investigate the prognostic value of the maximum standardised uptake value (SUVmax) and the volumetric parameters of metabolic tumour volume (MTV) and total lesion glycolysis (TLG) before and after treatment in women with cervical cancer, with overall survival (OS) and recurrence as outcome measures. METHODS Women with cervical cancer referred for curative radiotherapy and who underwent two PET-CT scans (before treatment and approximately 7 months post-treatment) were included. SUVmax, MTV and TLG were measured at baseline and post-treatment on the primary tumour, pelvic and distant lymph node metastases, distant organ metastases, and on total tumour burden. The PET parameters were associated with OS by Cox regression and recurrence by multivariable logistic regression. Kaplan-Meier curves and C-index were used to visualise the prognostic potential of the different measures. RESULTS A total of 133 patients were included. At the primary tumour level and on total tumour burden, age- and clinical-stage adjusted analyses showed a significant association between PET parameters and OS and recurrence when measured post-treatment. At baseline (pre-treatment), MTV and TLG were associated with OS and recurrence, whereas SUVmax was not. C-index from adjusted Cox models on total tumour burden showed higher values for the post-treatment PET compared to baseline. Kaplan-Meier curves demonstrated a greater prognostic potential for MTV and TLG compared to SUVmax, both at baseline and post-treatment. CONCLUSIONS The FDG PET-CT-derived parameters SUVmax, MTV, and TLG measured post-treatment can predict OS and recurrence in cervical cancer. Parameters measured before treatment had overall lower prognostic potential, and only MTV and TLG showed significant association to OS and recurrence.
Collapse
Affiliation(s)
- Maria Markus
- Clinical Physiology and Nuclear Medicine, Skåne University Hospital, Lund University, Malmö, Sweden.,Wallenberg Centre for Molecular Medicine, Lund University, Lund, Sweden
| | - Hanna Sartor
- Diagnostic Radiology, Department of Translational Medicine, Lund University, Skåne University Hospital, Lund, Sweden
| | - Maria Bjurberg
- Department of Hematology, Oncology and radiation Physics, Skåne University Hospital.,Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Elin Trägårdh
- Clinical Physiology and Nuclear Medicine, Skåne University Hospital, Lund University, Malmö, Sweden.,Wallenberg Centre for Molecular Medicine, Lund University, Lund, Sweden
| |
Collapse
|
5
|
Hristov D, Mustonen L, von Eyben R, Gotschel S, Minion M, El Kaffas A. Dynamic Contrast-Enhanced Ultrasound Modeling of an Analog to Pseudo-Diffusivity in Intravoxel Incoherent Motion Magnetic Resonance Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2022; 41:3824-3834. [PMID: 35939460 PMCID: PMC10101718 DOI: 10.1109/tmi.2022.3197363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Tumor perfusion and vascular properties are important determinants of cancer response to therapy and thus various approaches for imaging perfusion are being explored. In particular, Intravoxel Incoherent Motion (IVIM) MRI has been actively researched as an alternative to Dynamic-Contrast-Enhanced (DCE) CT and DCE-MRI as it offers non-ionizing, non-contrast-based perfusion imaging. However, for repetitive treatment assessment in a short time period, high cost, limited access, and inability to scan at the bedside remain disadvantages of IVIM MRI. We propose an analysis framework that may enable 3D DCE Ultrasound (DCE-US) - low cost, bedside imaging with excellent safety record - as an alternative modality to IVIM MRI for the generation of DCE-US based pseudo-diffusivity maps in acoustically accessible anatomy and tumors. Modelling intravascular contrast propagation as a convective-diffusive process, we reconstruct parametric maps of pseudo-diffusivity by solving a large-scale fully coupled inverse problem without any assumptions regarding local constancy of the reconstructed parameters. In a mouse tumor model, we demonstrate that the 3D DCE-US pseudo-diffusivity is repeatable, sensitive to treatment with an antiangiogenic agent, and moderately correlated to histological measures of perfusion and angiogenesis.
Collapse
|
6
|
Cancer Detection and Quantification of Treatment Response Using Diffusion-Weighted MRI. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00068-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
7
|
Ross BD, Chenevert TL, Meyer CR. Retrospective Registration in Molecular Imaging. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00080-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
8
|
Johnson GB, Harms HJ, Johnson DR, Jacobson MS. PET Imaging of Tumor Perfusion: A Potential Cancer Biomarker? Semin Nucl Med 2020; 50:549-561. [PMID: 33059824 DOI: 10.1053/j.semnuclmed.2020.07.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Perfusion, as measured by imaging, is considered a standard of care biomarker for the evaluation of many tumors. Measurements of tumor perfusion may be used in a number of ways, including improving the visual detection of lesions, differentiating malignant from benign findings, assessing aggressiveness of tumors, identifying ischemia and by extension hypoxia within tumors, and assessing treatment response. While most clinical perfusion imaging is currently performed with CT or MR, a number of methods for PET imaging of tumor perfusion have been described. The inert PET radiotracer 15O-water PET represents the recognized gold standard for absolute quantification of tissue perfusion in both normal tissue and a variety of pathological conditions including cancer. Other cancer PET perfusion imaging strategies include the use of radiotracers with high first-pass uptake, analogous to those used in cardiac perfusion PET. This strategy produces more visually pleasing high-contrast images that provide relative rather than absolute perfusion quantification. Lastly, multiple timepoint imaging of PET tracers such as 18F-FDG, are not specifically optimized for perfusion, but have advantages related to availability, convenience, and reimbursement. Multiple obstacles have thus far blocked the routine use of PET imaging for tumor perfusion, including tracer production and distribution, image processing, patient body coverage, clinical validation, regulatory approval and reimbursement, and finally feasible clinical workflows. Fortunately, these obstacles are being overcome, especially within larger imaging centers, opening the door for PET imaging of tumor perfusion to become standard clinical practice. In the foreseeable future, it is possible that whole-body PET perfusion imaging with 15O-water will be able to be performed in a single imaging session concurrent with standard PET imaging techniques such as 18F-FDG-PET. This approach could establish an efficient clinical workflow. The resultant ability to measure absolute tumor blood flow in combination with glycolysis will provide important complementary information to inform prognosis and clinical decisions.
Collapse
Affiliation(s)
- Geoffrey B Johnson
- Department of Radiology, Mayo Clinic, Rochester, MNDepartment of Neurology, Mayo Clinic, Rochester, MN; Department of Immunology, Mayo Clinic, Rochester, MN.
| | - Hendrik J Harms
- Department of Surgical Sciences, Nuclear Medicine, PET and Radiology, Uppsala University, Uppsala Sweden
| | - Derek R Johnson
- Department of Radiology, Mayo Clinic, Rochester, MNDepartment of Neurology, Mayo Clinic, Rochester, MN
| | - Mark S Jacobson
- Department of Radiology, Mayo Clinic, Rochester, MNDepartment of Neurology, Mayo Clinic, Rochester, MN
| |
Collapse
|