Martin-Paulpeter RM, Jensen PJ, Perles LA, Sawakuchi GO, Das P, Koay EJ, Koong AC, Ludmir EB, Niedzielski JS, Beddar S. Daily Diagnostic Quality Computed Tomography-on-Rails (CTOR) Image Guidance for Abdominal Stereotactic Body Radiation Therapy (SBRT). Cancers (Basel) 2024; 16:3770. [PMID: 39594725 PMCID: PMC11591933 DOI: 10.3390/cancers16223770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2024] [Accepted: 11/06/2024] [Indexed: 11/28/2024] Open
Abstract
BACKGROUND/OBJECTIVES Stereotactic body radiation therapy (SBRT) for abdominal targets faces a variety of challenges, including motion caused by the respiration and digestion and a relatively poor level of contrast between the tumor and the surrounding tissues. Breath-hold treatments with computed tomography-on-rails (CTOR) image guidance is one way of addressing these challenges, allowing for both the tumor and normal tissues to be well-visualized. Using isodose lines (IDLs) from CT simulations as a guide, the anatomical information can be used to shift the alignment or trigger a replan, such that normal tissues receive acceptable doses of radiation. METHODS This study aims to describe the workflow involved when using CTOR for pancreas and liver SBRT and demonstrates its effectiveness through several case studies. RESULTS In these case studies, using the anatomical information gained through diagnostic-quality CT guidance to make slight adjustments to the alignment, resulted in reductions in the maximum dose to the stomach. CONCLUSIONS High-quality imaging, such as CTOR, and the use of IDLs to estimate the doses to OARs, enable the safe delivery of SBRT, without the added complexity and resource commitment required by daily online adaptive planning.
Collapse
Affiliation(s)
- Rachael M. Martin-Paulpeter
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA (L.A.P.)
| | - P. James Jensen
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA (L.A.P.)
| | - Luis A. Perles
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA (L.A.P.)
| | - Gabriel O. Sawakuchi
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA (L.A.P.)
| | - Prajnan Das
- Department of Gastrointestinal Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Eugene J. Koay
- Department of Gastrointestinal Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Albert C. Koong
- Department of Gastrointestinal Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Ethan B. Ludmir
- Department of Gastrointestinal Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Joshua S. Niedzielski
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA (L.A.P.)
| | - Sam Beddar
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA (L.A.P.)
| |
Collapse
|
2
|
Song Y, Chen X, Yu X, Dong Y, Tian J, Wang X, Wang Y, Jiang B. Dosimetric comparison of multiple SBRT delivery platforms for pancreatic cancer. Eur J Med Res 2024; 29:533. [PMID: 39497204 PMCID: PMC11536576 DOI: 10.1186/s40001-024-02080-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2024] [Accepted: 09/24/2024] [Indexed: 11/07/2024] Open
Abstract
BACKGROUND Stereotactic body radiation therapy (SBRT) has been widely used for pancreatic cancer. However, there is still a lack of studies comparing the latest SBRT techniques in terms of clinical efficacy and safety. OBJECTIVES This study aims to evaluate three latest SBRT delivery platforms: CyberKnife (CK), Tomography Radixact (TOMO), and Halcyon volume rotation intensity modulation therapy (VMAT) for the treatment of pancreatic cancer. METHODS Sixteen patients with pancreatic cancer treated with CK were retrospectively analyzed. SBRT plans were designed using Precision and Eclipse software. CK plans were optimized in two forms: fixed collimator (CK-Fixed) and multi-leaf grating collimator (CK-MLC). TOMO plans were designed with 2.5 cm Fixed Jaw, pitch 0.123-0.43 and 4.0 modulation factors in precision system. In Eclipse 15.6 system, photon optimizer (OP) algorithm was used to design the coplanar two-arc Halcyon VMAT. The median radiation dose was 40 Gy (35-45 Gy) in 5 fractions. The effectiveness of clinical treatment was evaluated by comparing the homogeneity index (HI), conformity index (CI), coverage of the planning target volume (PTV) and dose distribution parameters of organs at risk (OAR). RESULTS All plans met the limits of clinical target dose and OAR. CK-MLC plans had the lowest maximum dose of 2 cm normal tissue from PTV margin (D2cm), indicating a low risk of peripheral radiation damage. Additionally, the CK-MLC plans had the lowest dose parameters and provided the best protection for the kidney, spinal cord, small intestine, and duodenum, with a paired t-test p < 0.05, indicating a statistical difference. CONCLUSION High conformity and adjustability of CK-MLC allowed for precise complex target localization and conformal dose distribution, benefiting tumor treatment while maximally reducing damage to OAR. This study provides valuable dosimetric evidence for SBRT technique selection for pancreatic cancer.
Collapse
Affiliation(s)
- Yongchun Song
- Department of Radiation Oncology, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Tianjin, 300060, People's Republic of China
| | - Xiuli Chen
- Department of Radiotherapy, Tianjin Hospital, Tianjin, 300200, People's Republic of China
| | - Xuyao Yu
- Department of Radiation Oncology, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Tianjin, 300060, People's Republic of China
| | - Yang Dong
- Department of Radiation Oncology, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Tianjin, 300060, People's Republic of China
| | - Jia Tian
- Department of Radiation Oncology, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Tianjin, 300060, People's Republic of China
| | - Xin Wang
- Department of Radiation Oncology, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Tianjin, 300060, People's Republic of China
| | - Yuwen Wang
- Department of Radiotherapy, Tianjin Cancer Hospital Airport Hospital, Tianjin, 300308, People's Republic of China.
| | - Bo Jiang
- Department of Radiotherapy, Tianjin Cancer Hospital Airport Hospital, Tianjin, 300308, People's Republic of China.
| |
Collapse
|
3
|
Young T, Lee M, Johnston M, Nguyen T, Ko R, Arumugam S. Assessment of interfraction dose variation in pancreas SBRT using daily simulation MR images. Phys Eng Sci Med 2023; 46:1619-1627. [PMID: 37747645 DOI: 10.1007/s13246-023-01324-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 08/24/2023] [Indexed: 09/26/2023]
Abstract
Pancreatic Cancer is associated with poor treatment outcomes compared to other cancers. High local control rates have been achieved by using hypofractionated stereotactic body radiotherapy (SBRT) to treat pancreatic cancer. Challenges in delivering SBRT include close proximity of several organs at risk (OARs) and target volume inter and intra fraction positional variations. Magnetic resonance image (MRI) guided radiotherapy has shown potential for online adaptive radiotherapy for pancreatic cancer, with superior soft tissue contrast compared to CT. The aim of this study was to investigate the variability of target and OAR volumes for different treatment approaches for pancreatic cancer, and to assess the suitability of utilizing a treatment-day MRI for treatment planning purposes. Ten healthy volunteers were scanned on a Siemens Skyra 3 T MRI scanner over two sessions (approximately 3 h apart), per day over 5 days to simulate an SBRT daily simulation scan for treatment planning. A pretreatment scan was also done to simulate patient setup and treatment. A 4D MRI scan was taken at each session for internal target volume (ITV) generation and assessment. For each volunteer a treatment plan was generated in the Raystation treatment planning system (TPS) following departmental protocols on the day one, first session dataset (D1S1), with bulk density overrides applied to enable dose calculation. This treatment plan was propagated through other imaging sessions, and the dose calculated. An additional treatment plan was generated on each first session of each day (S1) to simulate a daily replan process, with this plan propagated to the second session of the day. These accumulated mock treatment doses were assessed against the original treatment plan through DVH comparison of the PTV and OAR volumes. The generated ITV showed large variations when compared to both the first session ITV and daily ITV, with an average magnitude of 22.44% ± 13.28% and 25.83% ± 37.48% respectively. The PTV D95 was reduced by approximately 23.3% for both plan comparisons considered. Surrounding OARs had large variations in dose, with the small bowel V30 increasing by 128.87% when compared to the D1S1 plan, and 43.11% when compared to each daily S1 plan. Daily online adaptive radiotherapy is required for accurate dose delivery for pancreas cancer in the absence of additional motion management and tumour tracking techniques.
Collapse
Affiliation(s)
- Tony Young
- Liverpool and Macarthur Cancer Therapy Centres, Sydney, Australia.
- Ingham Institute, Sydney, Australia.
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, Australia.
| | - Mark Lee
- Liverpool and Macarthur Cancer Therapy Centres, Sydney, Australia
| | | | - Theresa Nguyen
- Liverpool and Macarthur Cancer Therapy Centres, Sydney, Australia
| | - Rebecca Ko
- Liverpool and Macarthur Cancer Therapy Centres, Sydney, Australia
| | - Sankar Arumugam
- Liverpool and Macarthur Cancer Therapy Centres, Sydney, Australia
- Ingham Institute, Sydney, Australia
- South Western Sydney Clinical School, University of New South Wales, Sydney, Australia
| |
Collapse
|
4
|
Uchinami Y, Kanehira T, Nakazato K, Fujita Y, Koizumi F, Takahashi S, Otsuka M, Yasuda K, Taguchi H, Nishioka K, Miyamoto N, Yokokawa K, Suzuki R, Kobashi K, Takahashi K, Katoh N, Aoyama H. Predicting the daily gastrointestinal doses of stereotactic body radiation therapy for pancreatic cancer based on the shortest distance between the tumor and the gastrointestinal tract using daily computed tomography images. BJR Open 2023; 5:20230043. [PMID: 37942491 PMCID: PMC10630971 DOI: 10.1259/bjro.20230043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 07/18/2023] [Accepted: 09/06/2023] [Indexed: 11/10/2023] Open
Abstract
Objectives We aimed to investigate whether daily computed tomography (CT) images could predict the daily gastroduodenal, small intestine, and large intestine doses of stereotactic body radiation therapy (SBRT) for pancreatic cancer based on the shortest distance between the gross tumor volume (GTV) and gastrointestinal (GI) tract. Methods Twelve patients with pancreatic cancer received SBRT of 40 Gy in five fractions. We recalculated the reference clinical SBRT plan (PLANref) using daily CT images and calculated the shortest distance from the GTV to each GI tract. The maximum dose delivered to 0.5 cc (D0.5cc) was evaluated for each planning at-risk volume of the GI tract. Spearman's correlation test was used to determine the association between the daily change in the shortest distance (Δshortest distance) and the ratio of ΔD0.5cc dose to D0.5cc dose in PLANref (ΔD0.5cc/PLANref) for quantitative analysis. Results The median shortest distance in PLANref was 0 mm in the gastroduodenum (interquartile range, 0-2.7), 16.7 mm in the small intestine (10.0-23.7), and 16.7 mm in the large intestine (8.3-28.1 mm). The D0.5cc of PLANref in the gastroduodenum was >30 Gy in all patients, with 10 (83.3%) having the highest dose. A significant association was found between the Δshortest distance and ΔD0.5cc/ PLANref in the small or large intestine (p < 0.001) but not in the gastroduodenum (p = 0.404). Conclusions The gastroduodenum had a higher D0.5cc and predicting the daily dose was difficult. Daily dose calculations of the GI tract are recommended for safe SBRT. Advances in knowledge This study aimed to predict the daily doses in SBRT for pancreatic cancer from the shortest distance between the GTV and the gastrointestinal tract.Daily changes in the shortest distance can predict the daily dose to the small or large intestines, but not to the gastroduodenum.
Collapse
Affiliation(s)
- Yusuke Uchinami
- Department of Radiation Oncology, Hokkaido University Faculty of Medicine and Graduate School of Medicine, Sapporo, Japan
| | - Takahiro Kanehira
- Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
| | - Keiji Nakazato
- Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
| | - Yoshihiro Fujita
- Department of Radiation Oncology, Hokkaido University Faculty of Medicine and Graduate School of Medicine, Sapporo, Japan
| | - Fuki Koizumi
- Department of Radiation Oncology, Hokkaido University Faculty of Medicine and Graduate School of Medicine, Sapporo, Japan
| | - Shuhei Takahashi
- Department of Radiation Oncology, Hokkaido University Faculty of Medicine and Graduate School of Medicine, Sapporo, Japan
| | - Manami Otsuka
- Department of Radiation Oncology, Hokkaido University Faculty of Medicine and Graduate School of Medicine, Sapporo, Japan
| | - Koichi Yasuda
- Department of Radiation Oncology, Hokkaido University Hospital, Sapporo, Japan
| | - Hiroshi Taguchi
- Department of Radiation Oncology, Hokkaido University Hospital, Sapporo, Japan
| | - Kentaro Nishioka
- Global Center for Biomedical Science and Engineering, Hokkaido University Faculty of Medicine, Sapporo, Japan
| | - Naoki Miyamoto
- Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
| | - Kohei Yokokawa
- Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
| | - Ryusuke Suzuki
- Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
| | - Keiji Kobashi
- Global Center for Biomedical Science and Engineering, Hokkaido University Faculty of Medicine, Sapporo, Japan
| | - Keita Takahashi
- Institute of Health Science Innovation for Medical Care, Hokkaido University Hospital, Sapporo, Japan
| | - Norio Katoh
- Department of Radiation Oncology, Hokkaido University Faculty of Medicine and Graduate School of Medicine, Sapporo, Japan
| | - Hidefumi Aoyama
- Department of Radiation Oncology, Hokkaido University Faculty of Medicine and Graduate School of Medicine, Sapporo, Japan
| |
Collapse
|
5
|
Ogawa A, Yoshimura M, Nakamura M, Adachi T, Iwai T, Ashida R, Mizowaki T. Impact of planning organ at risk volume margins and matching method on late gastrointestinal toxicity in moderately hypofractionated IMRT for locally advanced pancreatic ductal adenocarcinoma. Radiat Oncol 2023; 18:103. [PMID: 37337247 PMCID: PMC10280835 DOI: 10.1186/s13014-023-02288-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 05/24/2023] [Indexed: 06/21/2023] Open
Abstract
BACKGROUND This study examined the differences in late gastrointestinal (GI) toxicities in moderately hypofractionated intensity-modulated radiation therapy (IMRT) for locally advanced pancreatic ductal adenocarcinoma (LA-PDAC) by changing the planning organs at risk volume (PRV) margin and the target matching method and assessed the causes of adverse events. METHODS We examined 37 patients with LA-PDAC who underwent moderately hypofractionated IMRT between 2016 and 2020 at our institution; 23 patients were treated with wide PRV margins and soft tissue matching (Protocol A) and 14 with narrow PRV margins and fiducial marker matching (Protocol B). The GI toxicities, local control (LC) rate, and overall survival (OS) were assessed for each protocol. The initially planned and daily doses to the gross tumor volume (GTV), stomach, and duodenum, reproduced from cone-beam computed tomography, were evaluated. RESULTS The late GI toxicity rate of grades 3-4 was higher in Protocol B (42.9%) than in Protocol A (4.3%). Although the 2-year LC rates were significantly higher in Protocol B (90.0%) than in Protocol A (33.3%), no significant difference was observed in OS rates. In the initial plan, no deviations were found for the stomach and duodenum from the dose constraints in either protocol. In contrast, daily dose evaluation for the stomach to duodenal bulb revealed that the frequency of deviation of V3 Gy per session was 44.8% in Protocol B, which was significantly higher than the 24.3% in Protocol A. CONCLUSIONS Reducing PRV margins with fiducial marker matching increased GI toxicities in exchange for improved LC. Daily dose analysis indicated the trade-off between the GTV dose coverage and the irradiated doses to the GI. This study showed that even with strict matching methods, the PRV margin could not be reduced safely because of GI inter-fractional error, which is expected to be resolved with online adaptive radiotherapy.
Collapse
Affiliation(s)
- Ayaka Ogawa
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Michio Yoshimura
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan.
| | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
- Department of Advanced Medical Physics, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Takanori Adachi
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Takahiro Iwai
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Ryo Ashida
- Department of Radiation Oncology, Kobe City Medical Center General Hospital, 2-1-1, Minatojima Minamimachi, Chuo-ku, Kobe, 650-0047, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| |
Collapse
|
6
|
Sasaki M, Nakamura M, Ashida R, Nakata M, Yoshimura M, Mizowaki T. Assessing target localization accuracy across different soft-tissue matching protocols using end-exhalation breath-hold cone-beam computed tomography in patients with pancreatic cancer. JOURNAL OF RADIATION RESEARCH 2023:rrad048. [PMID: 37336503 DOI: 10.1093/jrr/rrad048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 03/23/2023] [Indexed: 06/21/2023]
Abstract
The purpose of this study was to retrospectively assess target localization accuracy across different soft-tissue matching protocols using cone-beam computed tomography (CBCT) in a large sample of patients with pancreatic cancer and to estimate the optimal margin size for each protocol. Fifty-four consecutive patients with pancreatic cancer who underwent 15-fraction volumetric modulated arc therapy under the end-exhalation breath-hold condition were enrolled. Two soft-tissue matching protocols were used according to the resectability classification, including gross tumor volume (GTV) matching for potentially resectable tumors and planning target volume (PTV) matching for borderline resectable or unresectable tumors. The tolerance of the target localization error in both matching protocols was set to 5 mm in any direction. The optimal margin size for each soft-tissue matching protocol was calculated from the systematic and random errors of the inter- and intrafraction positional variations using the van Herk formula. The inter- and intrafraction positional variations of PTV matching were smaller than those of GTV matching. The percentage of target localization errors exceeding 5 mm in the first CBCT scan of each fraction in the superior-inferior direction was 12.6 and 4.8% for GTV and PTV matching, respectively. The optimal margin sizes for GTV and PTV matching were 3.7 and 2.7, 5.4 and 4.1 and 3.9 and 3.0 mm in the anterior-posterior, superior-inferior and left-right directions, respectively. Target localization accuracy in PTV matching was higher than that in GTV matching. By setting the tolerance of the target localization error, treatment can be successful within the planned margin size.
Collapse
Affiliation(s)
- Makoto Sasaki
- Division of Clinical Radiology Service, Kyoto University Hospital, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan
| | - Mitsuhiro Nakamura
- Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Kawaharacho, Shogoin, Sakyo-ku, Kyoto 606-8397, Japan
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto University, Kyoto 606-8507, Japan
| | - Ryo Ashida
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto University, Kyoto 606-8507, Japan
| | - Manabu Nakata
- Division of Clinical Radiology Service, Kyoto University Hospital, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan
| | - Michio Yoshimura
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto University, Kyoto 606-8507, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto University, Kyoto 606-8507, Japan
| |
Collapse
|
7
|
Rhee DJ, Beddar S, Jaoude JA, Sawakuchi G, Martin R, Perles L, Yu C, He Y, Court LE, Ludmir EB, Koong AC, Das P, Koay EJ, Taniguichi C, Niedzielski JS. Dose Escalation for Pancreas SBRT: Potential and Limitations of using Daily Online Adaptive Radiation Therapy and an Iterative Isotoxicity Automated Planning Approach. Adv Radiat Oncol 2023; 8:101164. [PMID: 36798731 PMCID: PMC9926193 DOI: 10.1016/j.adro.2022.101164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Accepted: 12/23/2022] [Indexed: 02/05/2023] Open
Abstract
Purpose To determine the dosimetric limitations of daily online adaptive pancreas stereotactic body radiation treatment by using an automated dose escalation approach. Methods and Materials We collected 108 planning and daily computed tomography (CT) scans from 18 patients (18 patients × 6 CT scans) who received 5-fraction pancreas stereotactic body radiation treatment at MD Anderson Cancer Center. Dose metrics from the original non-dose-escalated clinical plan (non-DE), the dose-escalated plan created on the original planning CT (DE-ORI), and the dose-escalated plan created on daily adaptive radiation therapy CT (DE-ART) were analyzed. We developed a dose-escalation planning algorithm within the radiation treatment planning system to automate the dose-escalation planning process for efficiency and consistency. In this algorithm, the prescription dose of the dose-escalation plan was escalated before violating any organ-at-risk (OAR) dose constraint. Dose metrics for 3 targets (gross target volume [GTV], tumor vessel interface [TVI], and dose-escalated planning target volume [DE-PTV]) and 9 OARs (duodenum, large bowel, small bowel, stomach, spinal cord, kidneys, liver, and skin) for the 3 plans were compared. Furthermore, we evaluated the effectiveness of the online adaptive dose-escalation planning process by quantifying the effect of the interfractional dose distribution variations among the DE-ART plans. Results The median D95% dose to the GTV/TVI/DE-PTV was 33.1/36.2/32.4 Gy, 48.5/50.9/40.4 Gy, and 53.7/58.2/44.8 Gy for non-DE, DE-ORI, and DE-ART, respectively. Most OAR dose constraints were not violated for the non-DE and DE-ART plans, while OAR constraints were violated for the majority of the DE-ORI patients due to interfractional motion and lack of adaptation. The maximum difference per fraction in D95%, due to interfractional motion, was 2.5 ± 2.7 Gy, 3.0 ± 2.9 Gy, and 2.0 ± 1.8 Gy for the TVI, GTV, and DE-PTV, respectively. Conclusions Most patients require daily adaptation of the radiation planning process to maximally escalate delivered dose to the pancreatic tumor without exceeding OAR constraints. Using our automated approach, patients can receive higher target dose than standard of care without violating OAR constraints.
Collapse
Affiliation(s)
- Dong Joo Rhee
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Sam Beddar
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Joseph Abi Jaoude
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Gabriel Sawakuchi
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Rachael Martin
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Luis Perles
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Cenji Yu
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
- The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX, USA
| | - Yulun He
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
- The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX, USA
| | - Laurence E. Court
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Ethan B. Ludmir
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Albert C. Koong
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Prajnan Das
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Eugene J. Koay
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Cullen Taniguichi
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Joshua S. Niedzielski
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
- Corresponding author: Joshua S. Niedzielski, PhD
| |
Collapse
|
8
|
Evaluation of short-term gastrointestinal motion and its impact on dosimetric parameters in stereotactic body radiation therapy for pancreatic cancer. Clin Transl Radiat Oncol 2023; 39:100576. [PMID: 36686564 PMCID: PMC9852488 DOI: 10.1016/j.ctro.2023.100576] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Revised: 12/26/2022] [Accepted: 01/03/2023] [Indexed: 01/09/2023] Open
Abstract
Background The aim of this study is to quantify the short-term motion of the gastrointestinal tract (GI-tract) and its impact on dosimetric parameters in stereotactic body radiation therapy (SBRT) for pancreatic cancer. Methods The analyzed patients were eleven pancreatic cancer patients treated with SBRT or proton beam therapy. To ensure a fair analysis, the simulation SBRT plan was generated on the planning CT in all patients with the dose prescription of 40 Gy in 5 fractions. The GI-tract motion (stomach, duodenum, small and large intestine) was evaluated using three CT images scanned at spontaneous expiration. After fiducial-based rigid image registration, the contours in each CT image were generated and transferred to the planning CT, then the organ motion was evaluated. Planning at risk volumes (PRV) of each GI-tract were generated by adding 5 mm margins, and the volume receiving at least 33 Gy (V33) < 0.5 cm3 was evaluated as the dose constraint. Results The median interval between the first and last CT scans was 736 s (interquartile range, IQR:624-986). To compensate for the GI-tract motion based on the planning CT, the necessary median margin was 8.0 mm (IQR: 8.0-10.0) for the duodenum and 14.0 mm (12.0-16.0) for the small intestine. Compared to the planned V33 with the worst case, the median V33 in the PRV of the duodenum significantly increased from 0.20 cm3 (IQR: 0.02-0.26) to 0.33 cm3 (0.10-0.59) at Wilcoxon signed-rank test (p = 0.031). Conclusion The short-term motions of the GI-tract lead to high dose differences.
Collapse
Key Words
- 4DCT, four-dimensional computed tomography,
- CTV, clinical target volume
- FFF, flattening filter-free
- GI-tract, gastrointestinal tract
- GTV, gross tumor volume
- Gastrointestinal tract
- IQR, interquartile range
- Intra-fractional motion
- MV, mega-voltage
- PRV, planning at risk volume
- PTV, planning target volume
- Pancreatic cancer
- ROI, region of interest
- SBRT
- SBRT, stereotactic body radiation therapy
- SD, standard deviation
- Short-term organ motion
- VMAT, volumetric modulated arc therapy
Collapse
|
9
|
Yang H, Zhao X, He Y, Tan X, Peng H, Zhong M, Li Q, Liu X, He Y, Luo H, Jin F. Dosimetric impacts of cone-beam computed tomography (CBCT)-based anatomic changes in intensity-modulated radiotherapy for cervical cancer. ANNALS OF TRANSLATIONAL MEDICINE 2022; 10:1381. [PMID: 36660724 PMCID: PMC9843308 DOI: 10.21037/atm-22-6157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 12/19/2022] [Indexed: 01/01/2023]
Abstract
Background To evaluate the effects of dose to tumors and organs at risk (OARs) on inter-fractional anatomic changes. Methods We evaluated nine patients with cervical cancer treated with intensity-modulated radiotherapy (IMRT) (45 Gy in 25 fractions) using kV cone-beam computed tomography (CBCT) image guidance once or twice a week before treatment. For each patient, the original plan on the computed tomography (CT) image was copied to merged images, and then the fractional doses were calculated. Subsequently, deformable accumulated doses were obtained by summing the fractional absolute doses into a single dose in MIM Maestro software. The volume changes in the target and OARs were compared between the original CT and merged CBCT images, and the differences in the fractional and accumulated doses were also evaluated. Results Sixty-nine merged CBCT images were obtained and analyzed in this study. For the target areas, the volume changes in the clinical target volume (CTV) and planning target volume (PTV) reached -18.05% and -24.11% at most, respectively. The fractional D2% of the CTV and PTV was generally higher than the original plans, and the accumulated deviations were 2.27%±0.82% (P<0.01) and 2.42%±1.28% (P<0.01), respectively. The fractional D98% of the PTV was underdosed up to 18.28% for 78% of patients, and the accumulated deviations were -2.06% to -17.29% (P<0.05). For the OARs, the bladder volume changes were the most dramatic, reducing up to 93.60%. The fractional Dmean and D2cc of the bladder were generally higher than the original plans, and there were significant differences in their accumulated values (P<0.05). There was no obvious trend of rectal volume change with -69.65% to 74.20%. The rectum Dmean and D2cc of the accumulated were not significantly different from the planned dose (P>0.05). Conclusions For patients with cervical cancer, the changes in bladder and rectal volume were greater than in the target volume. Although the volume changes in the bladder and rectum had no significant effect on D98% of the CTV and PTV, they had a significant effect on their own D2cc and the D2% of the CTV and PTV. More attention should be paid to the volume changes in the bladder and rectum in clinical work.
Collapse
Affiliation(s)
- Han Yang
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Xiujuan Zhao
- Department of Gynecological Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Yang He
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Xia Tan
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Haiyan Peng
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Mingsong Zhong
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Qicheng Li
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Xianfeng Liu
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Yanan He
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Huanli Luo
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Fu Jin
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| |
Collapse
|
10
|
Ogawa A, Nakamura M, Iramina H, Yoshimura M, Mizowaki T. Potential utility of cone-beam CT-guided adaptive radiotherapy under end-exhalation breath-hold conditions for pancreatic cancer. J Appl Clin Med Phys 2022; 24:e13827. [PMID: 36316795 PMCID: PMC9924116 DOI: 10.1002/acm2.13827] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 09/15/2022] [Accepted: 10/07/2022] [Indexed: 02/14/2023] Open
Abstract
PURPOSE The purpose of this study was to demonstrate the potential utility of cone-beam computed tomography (CBCT)-guided online adaptive radiotherapy (ART) under end-exhalation breath-hold (EE-BH) conditions for pancreatic cancer (PC). METHODS Eleven PC patients who underwent 15-fraction volumetric-modulated arc therapy under EE-BH conditions were included. Planning CT images and daily 165 CBCT images were imported into a dedicated treatment planning system. The prescription dose was set to 48 Gy in 15 fractions. The reference plan was automatically generated along with predefined clinical goals. After segmentation was completed on CBCT images, two different plans were generated: One was an adapted (ADP) plan in which re-optimization was performed on the anatomy of the day, and the other was a scheduled (SCH) plan, which was the same as the reference plan. The dose distributions calculated using the synthetic CT created from both planning CT and CBCT were compared between the two plans. Independent calculation-based quality assurance was also performed for the ADP plans, with a gamma passing rate of 3%/3 mm. RESULTS All clinical goals were successfully achieved during the reference plan generation. Of the 165 sessions, gross tumor volume D98% and clinical target volume D98% were higher in 100 (60.1%) and 122 (74.0%) ADP fractions. In each fraction, the V3 Gy < 1 cm3 of the stomach and duodenum was violated in 47 (28.5%) and 48 (29.1%), respectively, of the SCH fractions, whereas no violations were observed in the ADP fractions. There were statistically significant differences in the dose-volume indices between the SCH and ADP fractions (p < 0.05). The gamma passing rates were above 95% in all ADP fractions. CONCLUSIONS The CBCT-guided online ART under EE-BH conditions successfully reduced the dose to the stomach and duodenum while maintaining target coverage.
Collapse
Affiliation(s)
- Ayaka Ogawa
- Department of Radiation Oncology and Image‐Applied TherapyGraduate School of MedicineKyoto UniversityKyotoJapan
| | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image‐Applied TherapyGraduate School of MedicineKyoto UniversityKyotoJapan,Division of Medical PhysicsDepartment of Information Technology and Medical EngineeringHuman Health SciencesGraduate School of MedicineKyoto UniversityKyotoJapan
| | - Hiraku Iramina
- Department of Radiation Oncology and Image‐Applied TherapyGraduate School of MedicineKyoto UniversityKyotoJapan
| | - Michio Yoshimura
- Department of Radiation Oncology and Image‐Applied TherapyGraduate School of MedicineKyoto UniversityKyotoJapan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image‐Applied TherapyGraduate School of MedicineKyoto UniversityKyotoJapan
| |
Collapse
|
11
|
Kim M, Schiff JP, Price A, Laugeman E, Samson PP, Kim H, Badiyan SN, Henke LE. The first reported case of a patient with pancreatic cancer treated with cone beam computed tomography-guided stereotactic adaptive radiotherapy (CT-STAR). Radiat Oncol 2022; 17:157. [PMID: 36100866 PMCID: PMC9472353 DOI: 10.1186/s13014-022-02125-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 08/26/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Online adaptive stereotactic radiotherapy allows for improved target and organ at risk (OAR) delineation and inter-fraction motion management via daily adaptive planning. The use of adaptive SBRT for the treatment of pancreatic cancer (performed until now using only MRI or CT on rails-guided adaptive radiotherapy), has yielded promising outcomes. Herein we describe the first reported case of cone beam CT-guided stereotactic adaptive radiotherapy (CT-STAR) for the treatment of pancreatic cancer. CASE PRESENTATION A 61-year-old female with metastatic pancreatic cancer presented for durable palliation of a symptomatic primary pancreatic mass. She was prescribed 35 Gy/5 fractions utilizing CT-STAR. The patient was simulated utilizing an end-exhale CT with intravenous and oral bowel contrast. Both initial as well as daily adapted plans were created adhering to a strict isotoxicity approach in which coverage was sacrificed to meet critical luminal gastrointestinal OAR hard constraints. Kilovoltage cone beam CTs were acquired on each day of treatment and the radiation oncologist edited OAR contours to reflect the patient's anatomy-of-the-day. The initial and adapted plan were compared using dose volume histogram objectives, and the superior plan was delivered. Use of the initial treatment plan would have resulted in nine critical OAR hard constraint violations. The adapted plans achieved hard constraints in all five fractions for all four critical luminal gastrointestinal structures. CONCLUSIONS We report the successful treatment of a patient with pancreatic cancer treated with CT-STAR. Prior to this treatment, the delivery of ablative adaptive radiotherapy for pancreatic cancer was limited to clinics with MR-guided and CT-on-rails adaptive SBRT technology and workflows. CT-STAR is a promising modality with which to deliver stereotactic adaptive radiotherapy for pancreatic cancer.
Collapse
Affiliation(s)
- Minsol Kim
- Department of Electrical and Computer Engineering, School of Engineering and Applied Science, University of Virginia, 351 McCormick Rd, Charlottsville, VA, 22904, USA
| | - Joshua P Schiff
- Department of Radiation Oncology, Washington University School of Medicine in St. Louis, 4921 Parkview Place, Campus Box 8224, St. Louis, MO, 63110, USA.
| | - Alex Price
- Department of Radiation Oncology, Washington University School of Medicine in St. Louis, 4921 Parkview Place, Campus Box 8224, St. Louis, MO, 63110, USA
| | - Eric Laugeman
- Department of Radiation Oncology, Washington University School of Medicine in St. Louis, 4921 Parkview Place, Campus Box 8224, St. Louis, MO, 63110, USA
| | - Pamela P Samson
- Department of Radiation Oncology, Washington University School of Medicine in St. Louis, 4921 Parkview Place, Campus Box 8224, St. Louis, MO, 63110, USA
| | - Hyun Kim
- Department of Radiation Oncology, Washington University School of Medicine in St. Louis, 4921 Parkview Place, Campus Box 8224, St. Louis, MO, 63110, USA
| | - Shahed N Badiyan
- Department of Radiation Oncology, Washington University School of Medicine in St. Louis, 4921 Parkview Place, Campus Box 8224, St. Louis, MO, 63110, USA
| | - Lauren E Henke
- Department of Radiation Oncology, Washington University School of Medicine in St. Louis, 4921 Parkview Place, Campus Box 8224, St. Louis, MO, 63110, USA.
| |
Collapse
|
12
|
Tanaka O, Taniguchi T, Adachi K, Nakaya S, Kiryu T, Ukai A, Makita C, Matsuo M. Effect of stomach size on organs at risk in pancreatic stereotactic body radiotherapy. Radiat Oncol 2022; 17:136. [PMID: 35909121 PMCID: PMC9339195 DOI: 10.1186/s13014-022-02107-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 07/21/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND In clinical practice, the organs at risk (OARs) should be carefully determined when performing pancreatic stereotactic body radiotherapy (SBRT). We conducted a simulation study to examine the effect of the stomach size on the radiation dose to the OARs when performing pancreatic SBRT. METHODS Twenty-five cases were included in this study. Pancreatic head and body tumors were 2-cm-sized pseudotumors, which were included as gross target volume (GTV) contours. The stomach, pancreas, small intestine, liver, kidneys, and spinal cord were considered as the OARs. The prescription dose for planning target volume (PTV) was 40 Gy/5fx, and the dose limit for the OARs was determined. The dose to X% of the OAR volume at X values of 0.1, 5.0, and 10.0 cc (DX) and the percentage of the OAR volume that received more than X Gy were recorded. RESULTS In terms of the radiation dose to the pancreatic body tumors, the stomach size was positively correlated with a dose of D10cc [correlation coefficient (r) = 0.5516) to the stomach. The r value between the radiation dose to the pancreatic head tumor and the stomach size was 0.3499. The stomach size and radiation dose to the head and body of the pancreas were positively correlated (pancreatic head D10cc: r = 0.3979, pancreatic body D10cc: r = 0.3209). The larger the stomach, the larger the radiation dose to the healthy portion of the pancreas outside the PTV. CONCLUSIONS When performing pancreatic SBRT, the dose to the OARs depends on the stomach size. Reducing the dose to the stomach and pancreas can be achieved by shrinking the stomach.
Collapse
Affiliation(s)
- Osamu Tanaka
- Department of Radiation Oncology, Asahi University Hospital, 3-23 Hashimoto-cho, Gifu City, Gifu, 500-8523, Japan.
| | - Takuya Taniguchi
- Department of Radiation Oncology, Asahi University Hospital, 3-23 Hashimoto-cho, Gifu City, Gifu, 500-8523, Japan
| | - Kousei Adachi
- Department of Radiation Oncology, Asahi University Hospital, 3-23 Hashimoto-cho, Gifu City, Gifu, 500-8523, Japan
| | - Shuto Nakaya
- Department of Radiation Oncology, Asahi University Hospital, 3-23 Hashimoto-cho, Gifu City, Gifu, 500-8523, Japan
| | - Takuji Kiryu
- Department of Radiation Oncology, Asahi University Hospital, 3-23 Hashimoto-cho, Gifu City, Gifu, 500-8523, Japan
| | - Akira Ukai
- Department of Oral and Maxillofacial Surgery, Asahi University Hospital, 3-23 Hashimoto-cho, Gifu City, Gifu, 500-8523, Japan
| | - Chiyoko Makita
- Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu City, Gifu, 501-1194, Japan
| | - Masayuki Matsuo
- Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu City, Gifu, 501-1194, Japan
| |
Collapse
|
13
|
Magallon-Baro A, Milder MTW, Granton PV, den Toom W, Nuyttens JJ, Hoogeman MS. Impact of Using Unedited CT-Based DIR-Propagated Autocontours on Online ART for Pancreatic SBRT. Front Oncol 2022; 12:910792. [PMID: 35756687 PMCID: PMC9213731 DOI: 10.3389/fonc.2022.910792] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 05/19/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose To determine the dosimetric impact of using unedited autocontours in daily plan adaptation of patients with locally advanced pancreatic cancer (LAPC) treated with stereotactic body radiotherapy using tumor tracking. Materials and Methods The study included 98 daily CT scans of 35 LAPC patients. All scans were manually contoured (MAN), and included the PTV and main organs-at-risk (OAR): stomach, duodenum and bowel. Precision and MIM deformable image registration (DIR) methods followed by contour propagation were used to generate autocontour sets on the daily CT scans. Autocontours remained unedited, and were compared to MAN on the whole organs and at 3, 1 and 0.5 cm from the PTV. Manual and autocontoured OAR were used to generate daily plans using the VOLO™ optimizer, and were compared to non-adapted plans. Resulting planned doses were compared based on PTV coverage and OAR dose-constraints. Results Overall, both algorithms reported a high agreement between unclipped MAN and autocontours, but showed worse results when being evaluated on the clipped structures at 1 cm and 0.5 cm from the PTV. Replanning with unedited autocontours resulted in better OAR sparing than non-adapted plans for 95% and 84% plans optimized using Precision and MIM autocontours, respectively, and obeyed OAR constraints in 64% and 56% of replans. Conclusion For the majority of fractions, manual correction of autocontours could be avoided or be limited to the region closest to the PTV. This practice could further reduce the overall timings of adaptive radiotherapy workflows for patients with LAPC.
Collapse
Affiliation(s)
- Alba Magallon-Baro
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Maaike T W Milder
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Patrick V Granton
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Wilhelm den Toom
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Joost J Nuyttens
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Mischa S Hoogeman
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, Netherlands
| |