1
|
Miszczyk M, Hoeksema WF, Kuna K, Blamek S, Cuculich PS, Grehn M, Molon G, Nowicka Z, van der Ree MH, Robinson CG, Sajdok M, Verhoeff JJC, Postema PG, Blanck O. Stereotactic arrhythmia radioablation (STAR)-A systematic review and meta-analysis of prospective trials on behalf of the STOPSTORM.eu consortium. Heart Rhythm 2025; 22:80-89. [PMID: 39032525 DOI: 10.1016/j.hrthm.2024.07.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Revised: 07/12/2024] [Accepted: 07/13/2024] [Indexed: 07/23/2024]
Abstract
Stereotactic arrhythmia radioablation (STAR) is a noninvasive treatment of refractory ventricular tachycardia (VT). In this study, we aimed to systematically review prospective trials on STAR and pool harmonized outcome measures in a meta-analysis. After registration in the International Prospective Register of Systematic Reviews (PROSPERO: CRD42023439666), we searched OVID Medline, OVID Embase, Web of Science Core Collection, the Cochrane Central Register of Controlled Trials, and Google Scholar on November 9, 2023, to identify reports describing results of prospective trials evaluating STAR for VT. Risk of bias was assessed using the Risk Of Bias In Non-randomized Studies of Interventions tool. Meta-analysis was performed using generalized linear mixed models. We identified 10 prospective trials in which 82 patients were treated with STAR between 2016 and 2022. The 90-day rate of treatment-related grade ≥3 adverse events was 0.10 (95% confidence interval [CI] 0.04-0.2). The proportions of patients achieving given VT burden reductions were 0.61 (95% CI 0.45-0.74) for ≥95%, 0.80 (95% CI 0.62-0.91) for ≥75%, and 0.9 (95% CI 0.77-0.96) for ≥50% in 63 evaluable patients. The 1-year overall survival rate was 0.73 (95% CI 0.61-0.83) in 81 patients, 1-year freedom from recurrence was 0.30 (95% CI 0.16-0.49) in 61 patients, and 1-year recurrence-free survival was 0.21 in 60 patients (95% CI 0.08-0.46). Limitations include methodological heterogeneity across studies and moderate to significant risk of bias. In conclusion, STAR is a promising treatment method, characterized by moderate toxicity. We observed 1-year mortality of ≈27% in this population of critically ill patients suffering from refractory VT. Most patients experience a significant reduction in VT burden; however, 1-year recurrence rates are high. STAR should still be considered an investigational approach and recommended to patients primarily within the context of prospective trials.
Collapse
Affiliation(s)
- Marcin Miszczyk
- Comprehensive Cancer Center, Medical University of Vienna, Vienna, Austria; Collegium Medicum - Faculty of Medicine, WSB University, Dąbrowa Górnicza, Poland.
| | - Wiert F Hoeksema
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam UMC Location University of Amsterdam, Amsterdam Cardiovascular Sciences, Heart Failure & Arrhythmias, Amsterdam, The Netherlands
| | - Kasper Kuna
- Department of Biostatistics and Translational Medicine, Medical University of Łódź, Łódź, Poland
| | - Sławomir Blamek
- Department of Radiotherapy, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland
| | - Phillip S Cuculich
- Washington University School of Medicine in St. Louis, St. Louis, Missouri, USA
| | - Melanie Grehn
- Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Giulio Molon
- Department of Cardiology, IRCCS S.Cuore Don Calabria, Negrar VR, Italy
| | - Zuzanna Nowicka
- Department of Biostatistics and Translational Medicine, Medical University of Łódź, Łódź, Poland
| | - Martijn H van der Ree
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam UMC Location University of Amsterdam, Amsterdam Cardiovascular Sciences, Heart Failure & Arrhythmias, Amsterdam, The Netherlands
| | - Clifford G Robinson
- Washington University School of Medicine in St. Louis, St. Louis, Missouri, USA
| | - Mateusz Sajdok
- Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland; Department of Electrocardiology, Upper Silesian Medical Center of the Medical University of Silesia, Katowice, Poland; Doctoral School of the Medical University of Silesia, Katowice, Poland
| | - Joost J C Verhoeff
- Department of Radiation Oncology, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands
| | - Pieter G Postema
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam UMC Location University of Amsterdam, Amsterdam Cardiovascular Sciences, Heart Failure & Arrhythmias, Amsterdam, The Netherlands
| | - Oliver Blanck
- Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel, Germany
| |
Collapse
|
2
|
Li G, Wang G, Wei W, Li Z, Xiao Q, He H, Luo D, Chen L, Li J, Zhang X, Song Y, Bai S. Cardiorespiratory motion characteristics and their dosimetric impact on cardiac stereotactic body radiotherapy. Med Phys 2024; 51:8551-8567. [PMID: 38994881 DOI: 10.1002/mp.17284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 06/19/2024] [Accepted: 06/20/2024] [Indexed: 07/13/2024] Open
Abstract
BACKGROUND Cardiac stereotactic body radiotherapy (CSBRT) is an emerging and promising noninvasive technique for treating refractory arrhythmias utilizing highly precise, single or limited-fraction high-dose irradiations. This method promises to revolutionize the treatment of cardiac conditions by delivering targeted therapy with minimal exposure to surrounding healthy tissues. However, the dynamic nature of cardiorespiratory motion poses significant challenges to the precise delivery of dose in CSBRT, introducing potential variabilities that can impact treatment efficacy. The complexities of the influence of cardiorespiratory motion on dose distribution are compounded by interplay and blurring effects, introducing additional layers of dose uncertainty. These effects, critical to the understanding and improvement of the accuracy of CSBRT, remain unexplored, presenting a gap in current clinical literature. PURPOSE To investigate the cardiorespiratory motion characteristics in arrhythmia patients and the dosimetric impact of interplay and blurring effects induced by cardiorespiratory motion on CSBRT plan quality. METHODS The position and volume variations in the substrate target and cardiac substructures were evaluated in 12 arrhythmia patients using displacement maximum (DMX) and volume metrics. Moreover, a four-dimensional (4D) dose reconstruction approach was employed to examine the dose uncertainty of the cardiorespiratory motion. RESULTS Cardiac pulsation induced lower DMX than respiratory motion but increased the coefficient of variation and relative range in cardiac substructure volumes. The mean DMX of the substrate target was 0.52 cm (range: 0.26-0.80 cm) for cardiac pulsation and 0.82 cm (range: 0.32-2.05 cm) for respiratory motion. The mean DMX of the cardiac structure ranged from 0.15 to 1.56 cm during cardiac pulsation and from 0.35 to 1.89 cm during respiratory motion. Cardiac pulsation resulted in an average deviation of -0.73% (range: -4.01%-4.47%) in V25 between the 3D and 4D doses. The mean deviations in the homogeneity index (HI) and gradient index (GI) were 1.70% (range: -3.10%-4.36%) and 0.03 (range: -0.14-0.11), respectively. For cardiac substructures, the deviations in D50 due to cardiac pulsation ranged from -1.88% to 1.44%, whereas the deviations in Dmax ranged from -2.96% to 0.88% of the prescription dose. By contrast, the respiratory motion led to a mean deviation of -1.50% (range: -10.73%-4.23%) in V25. The mean deviations in HI and GI due to respiratory motion were 4.43% (range: -3.89%-13.98%) and 0.18 (range: -0.01-0.47) (p < 0.05), respectively. Furthermore, the deviations in D50 and Dmax in cardiac substructures for the respiratory motion ranged from -0.28% to 4.24% and -4.12% to 1.16%, respectively. CONCLUSIONS Cardiorespiratory motion characteristics vary among patients, with the respiratory motion being more significant. The intricate cardiorespiratory motion characteristics and CSBRT plan complexity can induce substantial dose uncertainty. Therefore, assessing individual motion characteristics and 4D dose reconstruction techniques is critical for implementing CSBRT without compromising efficacy and safety.
Collapse
Affiliation(s)
- Guangjun Li
- Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Guangyu Wang
- State Key Laboratory of Oncology in South China, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Weige Wei
- Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Zhibin Li
- Department of Radiotherapy & Oncology, The First Affiliated Hospital of Soochow University, Institute of Radiotherapy & Oncology, Soochow University, Suzhou, China
| | - Qing Xiao
- Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Haiping He
- Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Dashuang Luo
- Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Li Chen
- Department of Radiotherapy & Oncology, The Second Affiliated Hospital of Soochow University, Suzhou, China
| | - Jing Li
- Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Xiangyu Zhang
- Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Ying Song
- Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Sen Bai
- Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| |
Collapse
|
3
|
Kaya YS, Stoks J, Hazelaar C, van Elmpt W, Gommers S, Volders PGA, Verhoeven K, ter Bekke RMA. 3D-targeted, electrocardiographic imaging-aided stereotactic radioablation for ventricular tachycardia storm: a case report. Eur Heart J Case Rep 2024; 8:ytae541. [PMID: 39678105 PMCID: PMC11638725 DOI: 10.1093/ehjcr/ytae541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 08/13/2024] [Accepted: 09/17/2024] [Indexed: 12/17/2024]
Abstract
Background Stereotactic arrhythmia radioablation (STAR) is a promising non-invasive therapy for patients with ventricular tachycardia (VT). Accurate identification of the arrhythmogenic volume, or clinical target volume (CTV), on the radiotherapy (RT) 4D planning computed tomography (CT) scan is key for STAR efficacy and safety. This case report illustrates our workflow of electro-structural image integration for CTV delineation. Case summary A 72-year-old man with ischaemic cardiomyopathy and VT storm, despite two (endocardial and epicardial) catheter-based ablations, was consented for STAR. A 3D electro-structural arrhythmia model was generated from co-registered electroanatomical voltage and activation maps, electrocardiographic (ECG) imaging, and the cardiac CT angiography scan (in ADAS 3D), pinpointing the VT isthmus and inferoapical VT exit. At this location, an area with short recovery times was found with ECG imaging. A multidisciplinary team delineated the CTV on the transmural ventricular myocardium, which was fused with the 4D planning CT scan using a digital images and communication in medicine (DICOM) radiotherapy file. The CTV was 63% smaller compared with using the conventional American Heart Association 17-segment approach (11 vs. 24 cm3). A single fraction of 25 Gy was delivered to the internal target volume. After an 8-week blanking period, no VT recurrences or radiation-related side-effects were noted. Eight months later, the patient died from end-stage heart failure. Discussion We report a novel workflow for 3D-targeted and ECG imaging-aided CTV delineation for STAR, resulting in a smaller irradiated volume compared with segmental approaches. Acute and intermediate outcome and safety were favourable. Non-invasive ECG imaging at baseline and during induced VT holds promise for STAR guidance.
Collapse
Affiliation(s)
- Yeşim S Kaya
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center+, Postbus 5800, 6202 AZ Maastricht, The Netherlands
| | - Job Stoks
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center+, Postbus 5800, 6202 AZ Maastricht, The Netherlands
| | - Colien Hazelaar
- Department of Radiation Oncology (Maastro), GROW Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Doctor Tanslaan 12, 6229 ET Maastricht, The Netherlands
| | - Wouter van Elmpt
- Department of Radiation Oncology (Maastro), GROW Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Doctor Tanslaan 12, 6229 ET Maastricht, The Netherlands
| | - Suzanne Gommers
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Postbus 5800, 6202 AZ Maastricht, The Netherlands
| | - Paul G A Volders
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center+, Postbus 5800, 6202 AZ Maastricht, The Netherlands
| | - Karolien Verhoeven
- Department of Radiation Oncology (Maastro), GROW Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Doctor Tanslaan 12, 6229 ET Maastricht, The Netherlands
| | - Rachel M A ter Bekke
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center+, Postbus 5800, 6202 AZ Maastricht, The Netherlands
| |
Collapse
|
4
|
Poon J, Thompson RB, Deyell MW, Schellenberg D, Kohli K, Thomas S. Left ventricle segment-specific motion assessment for cardiac-gated radiosurgery. Biomed Phys Eng Express 2024; 10:025040. [PMID: 38359447 DOI: 10.1088/2057-1976/ad29a4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Accepted: 02/15/2024] [Indexed: 02/17/2024]
Abstract
Purpose.Cardiac radiosurgery is a non-invasive treatment modality for ventricular tachycardia, where a linear accelerator is used to irradiate the arrhythmogenic region within the heart. In this work, cardiac magnetic resonance (CMR) cine images were used to quantify left ventricle (LV) segment-specific motion during the cardiac cycle and to assess potential advantages of cardiac-gated radiosurgery.Methods.CMR breath-hold cine images and LV contour points were analyzed for 50 controls and 50 heart failure patients with reduced ejection fraction (HFrEF, EF < 40%). Contour points were divided into anatomic segments according to the 17-segment model, and each segment was treated as a hypothetical treatment target. The optimum treatment window (one fifth of the cardiac cycle) was determined where segment centroid motion was minimal, then the maximum centroid displacement and treatment area were determined for the full cardiac cycle and for the treatment window. Mean centroid displacement and treatment area reductions with cardiac gating were determined for each of the 17 segments.Results.Full motion segment centroid displacements ranged between 6-14 mm (controls) and 4-11 mm (HFrEF). Full motion treatment areas ranged between 129-715 mm2(controls) and 149-766 mm2(HFrEF). With gating, centroid displacements were reduced to 1 mm (controls and HFrEF), while treatment areas were reduced to 62-349 mm2(controls) and 83-393 mm2(HFrEF). Relative treatment area reduction ranged between 38%-53% (controls) and 26%-48% (HFrEF).Conclusion.This data demonstrates that cardiac cycle motion is an important component of overall target motion and varies depending on the anatomic cardiac segment. Accounting for cardiac cycle motion, through cardiac gating, has the potential to significantly reduce treatment volumes for cardiac radiosurgery.
Collapse
Affiliation(s)
- Justin Poon
- Department of Physics and Astronomy, University of British Columbia, Vancouver, BC V6T 1Z1, Canada
- Department of Medical Physics, BC Cancer, Vancouver, British Columbia V5Z 4E6, Canada
| | - Richard B Thompson
- Department of Biomedical Engineering, University of Alberta, Edmonton, AB, T6G 2V2, Canada
| | - Marc W Deyell
- Heart Rhythm Services, Division of Cardiology, University of British Columbia, Vancouver, BC V6E 1M7, Canada
| | - Devin Schellenberg
- Department of Radiation Oncology, BC Cancer, Surrey, British Columbia V3V 1Z2, Canada
| | - Kirpal Kohli
- Department of Medical Physics, BC Cancer, Surrey, British Columbia V3V 1Z2, Canada
| | - Steven Thomas
- Department of Medical Physics, BC Cancer, Vancouver, British Columbia V5Z 4E6, Canada
| |
Collapse
|