1
|
Siverino C, Vanvelk N, Nehrbass D, Mischler D, Geoff Richards R, Morgenstern M, Zeiter S, Arens D, Fintan Moriarty T. Comparative bone healing with induced membrane technique (IMT) versus empty defects in septic and aseptic conditions in a novel rabbit humerus model. BMC Musculoskelet Disord 2023; 24:886. [PMID: 37964215 PMCID: PMC10644571 DOI: 10.1186/s12891-023-07031-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 11/09/2023] [Indexed: 11/16/2023] Open
Abstract
BACKGROUND Long bone defects resulting from primary trauma or secondary to debridement of fracture-related infection (FRI) remain a major clinical challenge. One approach often used is the induced membrane technique (IMT). The effectiveness of the IMT in infected versus non-infected settings remains to be definitively established. In this study we present a new rabbit humerus model and compare the IMT approach between animals with prior infection and non-infected equivalents. METHODS A 5 mm defect was created in the humerus of New Zealand White rabbits (n = 53) and fixed with a 2.5 mm stainless steel plate. In the non-infected groups, the defect was either left empty (n = 6) or treated using the IMT procedure (PMMA spacer for 3 weeks, n = 6). Additionally, both approaches were applied in animals that were inoculated with Staphylococcus aureus 4 weeks prior to defect creation (n = 5 and n = 6, respectively). At the first and second revision surgeries, infected and necrotic tissues were debrided and processed for bacteriological quantification. In the IMT groups, the PMMA spacer was removed 3 weeks post implantation and replaced with a beta-tricalcium phosphate scaffold and bone healing observed for a further 10 weeks. Infected groups also received systemic antibiotic therapy. The differences in bone healing between the groups were evaluated radiographically using a modification of the radiographic union score for tibial fractures (RUST) and by semiquantitative histopathology on Giemsa-Eosin-stained sections. RESULTS The presence of S. aureus infection at revision surgery was required for inclusion to the second stage. At the second revision surgery all collected samples were culture negative confirming successful treatment. In the empty defect group, bone healing was increased in the previously infected animals compared with non-infected controls as revealed by radiography with significantly higher RUST values at 6 weeks (p = 0.0281) and at the end of the study (p = 0.0411) and by histopathology with increased cortical bridging (80% and 100% in cis and trans cortical bridging in infected animals compared to 17% and 67% in the non-infected animals). With the IMT approach, both infected and non-infected animals had positive healing assessments. CONCLUSION We successfully developed an in vivo model of bone defect healing with IMT with and without infection. Bone defects can heal after an infection with even better outcomes compared to the non-infected setting, although in both cases, the IMT achieved better healing.
Collapse
Affiliation(s)
- Claudia Siverino
- AO Research Institute Davos, Clavadelerstrasse 1, Davos-Platz, 7270, Switzerland
| | - Niels Vanvelk
- AO Research Institute Davos, Clavadelerstrasse 1, Davos-Platz, 7270, Switzerland
| | - Dirk Nehrbass
- AO Research Institute Davos, Clavadelerstrasse 1, Davos-Platz, 7270, Switzerland
| | - Dominic Mischler
- AO Research Institute Davos, Clavadelerstrasse 1, Davos-Platz, 7270, Switzerland
| | | | - Mario Morgenstern
- Center for Musculoskeletal Infections, Department of Orthopaedic and Trauma Surgery, University Hospital Basel, Basel, Switzerland
| | - Stephan Zeiter
- AO Research Institute Davos, Clavadelerstrasse 1, Davos-Platz, 7270, Switzerland
| | - Daniel Arens
- AO Research Institute Davos, Clavadelerstrasse 1, Davos-Platz, 7270, Switzerland
| | - Thomas Fintan Moriarty
- AO Research Institute Davos, Clavadelerstrasse 1, Davos-Platz, 7270, Switzerland.
- Center for Musculoskeletal Infections, Department of Orthopaedic and Trauma Surgery, University Hospital Basel, Basel, Switzerland.
| |
Collapse
|
2
|
Ren SQ, Ma Y, Fu LL, Hu KZ, Liang HR, Yu B, Tang GH. A comparative 18F-FDG and an anti-PD-L1 probe PET/CT imaging of implant-associated Staphylococcus aureus osteomyelitis. Front Cell Infect Microbiol 2023; 13:1182480. [PMID: 37293208 PMCID: PMC10244720 DOI: 10.3389/fcimb.2023.1182480] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 05/11/2023] [Indexed: 06/10/2023] Open
Abstract
Background Early and accurate diagnosis of infection-induced osteomyelitis, which often involves increased PD-L1 expression, is crucial for better treatment outcomes. Radiolabeled anti-PD-L1 nuclear imaging allows for sensitive and non-invasive whole-body assessments of PD-L1 expression. This study aimed to compare the efficacy of 18F-FDG and an 18F-labeled PD-L1-binding peptide probe (18F-PD-L1P) in PET imaging of implant-associated Staphylococcus aureus osteomyelitis (IAOM). Methods In this study, we synthesized an anti-PD-L1 probe and compared its efficacy with 18F-FDG and 18F-PD-L1P in PET imaging of implant-associated Staphylococcus aureus osteomyelitis (IAOM). The %ID/g ratios (i.e., radioactivity ratios between the infected and non-infected sides) of both probes were evaluated for sensitivity and accuracy in post-infected 7-day tibias and post-infected 21 days, and the intensity of 18F-PD-L1P uptake was compared with pathological changes measured by PD-L1 immunohistochemistry (IHC). Results Compared with 18F-FDG, 18F-PDL1P demonstrated higher %ID/g ratios for both post-infected 7-day tibias (P=0.001) and post-infected 21 days (P=0.028). The intensity of 18F-PD-L1P uptake reflected the pathological changes of osteomyelitic bones. In comparison to 18F-FDG, 18F-PDL1P provides earlier and more sensitive detection of osteomyelitis caused by S. aureus. Conclusion Our findings suggest that the 18F-PDL1P probe is a promising tool for the early and accurate detection of osteomyelitis caused by S. aureus.
Collapse
Affiliation(s)
- Shu-Qi Ren
- GuangDong Medical Products Administration (GDMPA) Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Yuan Ma
- Guangdong Provincial Key Laboratory of Bone and Cartilage Regenerative Medicine, Division of Orthopedics and Traumatology, Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Li-Lan Fu
- GuangDong Medical Products Administration (GDMPA) Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Kong-Zhen Hu
- GuangDong Medical Products Administration (GDMPA) Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Hao-Ran Liang
- GuangDong Medical Products Administration (GDMPA) Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Bin Yu
- Guangdong Provincial Key Laboratory of Bone and Cartilage Regenerative Medicine, Division of Orthopedics and Traumatology, Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Gang-Hua Tang
- GuangDong Medical Products Administration (GDMPA) Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| |
Collapse
|
3
|
Evenhuis JV, Verstraete FJM, Arzi B. Management of failed stainless steel implants in the oromaxillofacial region of dogs. Front Vet Sci 2022; 9:992730. [PMID: 36213415 PMCID: PMC9539114 DOI: 10.3389/fvets.2022.992730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 08/23/2022] [Indexed: 11/13/2022] Open
Abstract
Management of complications of fracture fixation in the oromaxillofacial (OMF) region may present a diagnostic and therapeutic challenge. While titanium and stainless steel implants have been utilized in successful fracture fixation in the OMF region, the use of titanium implants is preferred due to the superior intrinsic properties of titanium. Nonetheless, stainless steel materials are still used due to their availability and familiarity. In the present methods report, we describe our approach to the management of failed stainless steel plates and screws used to treat traumatic injuries in the OMF region. Furthermore, we exemplify our approach with five dogs that exhibited complications of stainless steel implants in the OMF region and their subsequent management. In those cases, all failed implants were removed. Reconstruction with a combination of recombinant human bone morphogenetic protein-2 (rhBMP-2) and titanium implants was utilized in two cases while a mandibulectomy was performed in one case. Three cases required removal of the stainless-steel implant with no additional surgical therapy. We conclude that the success of treatment of failed stainless steel implants depends on the use of advanced imaging findings, appropriate antimicrobial therapy, as well as potentially regenerative reconstructive surgery.
Collapse
Affiliation(s)
- Janny V. Evenhuis
- Dentistry and Oral Surgery Service, William R. Pritchard Veterinary Medical Teaching Hospital, School of Veterinary Medicine, University of California, Davis, Davis, CA, United States
| | - Frank J. M. Verstraete
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, Davis, CA, United States
| | - Boaz Arzi
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, Davis, CA, United States
- *Correspondence: Boaz Arzi
| |
Collapse
|
4
|
Laubscher M, Nieuwoudt L, Marais L. Effect of frame and fixation factors on the incidence of pin site infections in circular external fixation of the tibia: A systematic review of comparative studies. JOURNAL OF LIMB LENGTHENING & RECONSTRUCTION 2022. [DOI: 10.4103/jllr.jllr_1_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
|
5
|
Cyphert EL, Zhang N, Learn GD, Hernandez CJ, von Recum HA. Recent Advances in the Evaluation of Antimicrobial Materials for Resolution of Orthopedic Implant-Associated Infections In Vivo. ACS Infect Dis 2021; 7:3125-3160. [PMID: 34761915 DOI: 10.1021/acsinfecdis.1c00465] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
While orthopedic implant-associated infections are rare, revision surgeries resulting from infections incur considerable healthcare costs and represent a substantial research area clinically, in academia, and in industry. In recent years, there have been numerous advances in the development of antimicrobial strategies for the prevention and treatment of orthopedic implant-associated infections which offer promise to improve the limitations of existing delivery systems through local and controlled release of antimicrobial agents. Prior to translation to in vivo orthopedic implant-associated infection models, the properties (e.g., degradation, antimicrobial activity, biocompatibility) of the antimicrobial materials can be evaluated in subcutaneous implant in vivo models. The antimicrobial materials are then incorporated into in vivo implant models to evaluate the efficacy of using the material to prevent or treat implant-associated infections. Recent technological advances such as 3D-printing, bacterial genomic sequencing, and real-time in vivo imaging of infection and inflammation have contributed to the development of preclinical implant-associated infection models that more effectively recapitulate the clinical presentation of infections and improve the evaluation of antimicrobial materials. This Review highlights the advantages and limitations of antimicrobial materials used in conjunction with orthopedic implants for the prevention and treatment of orthopedic implant-associated infections and discusses how these materials are evaluated in preclinical in vivo models. This analysis serves as a resource for biomaterial researchers in the selection of an appropriate orthopedic implant-associated infection preclinical model to evaluate novel antimicrobial materials.
Collapse
Affiliation(s)
- Erika L. Cyphert
- Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106, United States
| | - Ningjing Zhang
- Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106, United States
| | - Greg D. Learn
- Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106, United States
| | - Christopher J. Hernandez
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, New York 14853, United States
- Hospital for Special Surgery, New York, New York 10021, United States
| | - Horst A. von Recum
- Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106, United States
| |
Collapse
|
6
|
Luca A, Gallazzi E, De Vecchi E, Brayda-Bruno M, Lovi A, Babbi L, Peretti GM, Bidossi A. Bacterial adhesion on spinal implants: An in vitro study of "hot spots". J Orthop Res 2021; 39:2209-2216. [PMID: 33331674 DOI: 10.1002/jor.24960] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Revised: 12/06/2020] [Accepted: 12/14/2020] [Indexed: 02/04/2023]
Abstract
Few studies evaluated bacterial colonization of spinal implants from a "topographic" point of view. This lack of knowledge could hinder the development of more effective strategies in the prevention and treatment of postoperative spinal infections. The aim of this in vitro study was the analysis of the adhesion pattern of sessile cells on conventional spinal implants, to identify "hot spots" on implants where bacterial adhesion could be favored. Clinically relevant Staphylococcus aureus, Staphylococcus epidermidis, and Pseudomonas aeruginosa isolates were grown on commercially available end product spinal implants. To identify sessile cells attached to implant surfaces, confocal laser scan microscopy was used. Different areas from the spinal instrumentations (both Ti and CoCr) were selected for biofilm quantification. Bacterial biofilm was markedly increased in the cut of the rods, both Ti and CoCr, as the uneven surface deriving from the cut might foster cell adhesion. Though not statistically significant, a difference was observed between the rod and the area of the notch, possibly as a consequence of the smoothening effect deriving from the bending of the rod. Finally, the amount of biofilm produced on cobalt-chromium surfaces was always more significant than that formed on titanium surfaces. This study highlights how bacterial adhesion through biofilm formation is favored on the surfaces of higher irregularity and that staphylococci are able to increase sessile biomass on CoCr surfaces. These preliminary results show how surface modifications on the implants may play a key role in bacterial adhesion, opening an exciting field for future research.
Collapse
Affiliation(s)
- Andrea Luca
- Spine Unit III, IRCCS Orthopedic Institute Galeazzi, Milan, Italy
| | - Enrico Gallazzi
- Spine Unit III, IRCCS Orthopedic Institute Galeazzi, Milan, Italy
| | - Elena De Vecchi
- Laboratory of Clinica Chemistry and Microbiology, IRCCS Orthopedic Institute Galeazzi, Milan, Italy
| | | | - Alessio Lovi
- Spine Unit III, IRCCS Orthopedic Institute Galeazzi, Milan, Italy
| | - Lisa Babbi
- Spine Unit III, IRCCS Orthopedic Institute Galeazzi, Milan, Italy
| | - Giuseppe Michele Peretti
- IRCCS Orthopedic Insitutute Galeazzi, Milan, Italy.,Department of Biomedical Science, University of Milan, Milan, Italy
| | - Alessandro Bidossi
- Laboratory of Clinica Chemistry and Microbiology, IRCCS Orthopedic Institute Galeazzi, Milan, Italy
| |
Collapse
|
7
|
Hersh A, Young R, Pennington Z, Ehresman J, Ding A, Kopparapu S, Cottrill E, Sciubba DM, Theodore N. Removal of instrumentation for postoperative spine infection: systematic review. J Neurosurg Spine 2021:1-13. [PMID: 34243152 DOI: 10.3171/2020.12.spine201300] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 12/14/2020] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Currently, no consensus exists as to whether patients who develop infection of the surgical site after undergoing instrumented fusion should have their implants removed at the time of wound debridement. Instrumentation removal may eliminate a potential infection nidus, but removal may also destabilize the patient's spine. The authors sought to summarize the existing evidence by systematically reviewing published studies that compare outcomes between patients undergoing wound washout and instrumentation removal with outcomes of patients undergoing wound washout alone. The primary objectives were to determine 1) whether instrumentation removal from an infected wound facilitates infection clearance and lowers morbidity, and 2) whether the chronicity of the underlying infection affects the decision to remove instrumentation. METHODS PRISMA guidelines were used to review the PubMed/MEDLINE, Embase, Cochrane Library, Scopus, Web of Science, and ClinicalTrials.gov databases to identify studies that compared patients with implants removed and patients with implants retained. Outcomes of interest included mortality, rate of repeat wound washout, and loss of correction. RESULTS Fifteen articles were included. Of 878 patients examined in these studies, 292 (33%) had instrumentation removed. Patient populations were highly heterogeneous, and outcome data were limited. Available data suggested that rates of reoperation, pseudarthrosis, and death were higher in patients who underwent instrumentation removal at the time of initial washout. Three studies recommended that instrumentation be uniformly removed at the time of wound washout. Five studies favored retaining the original instrumentation. Six studies favored retention in early infections but removal in late infections. CONCLUSIONS The data on this topic remain heterogeneous and low in quality. Retention may be preferred in the setting of early infection, when the risk of underlying spine instability is still high and the risk of mature biofilm formation on the implants is low. However, late infections likely favor instrumentation removal. Higher-quality evidence from large, multicenter, prospective studies is needed to reach generalizable conclusions capable of guiding clinical practice.
Collapse
|
8
|
Coppola GA, Onsea J, Moriarty TF, Nehrbass D, Constant C, Zeiter S, Aktan MK, Braem A, Van der Eycken EV, Steenackers HP, Metsemakers WJ. An Improved 2-Aminoimidazole Based Anti-Biofilm Coating for Orthopedic Implants: Activity, Stability, and in vivo Biocompatibility. Front Microbiol 2021; 12:658521. [PMID: 33967997 PMCID: PMC8097006 DOI: 10.3389/fmicb.2021.658521] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 03/19/2021] [Indexed: 12/02/2022] Open
Abstract
Orthopedic device-related infections remain a serious challenge to treat. Central to these infections are bacterial biofilms that form on the orthopedic implant itself. These biofilms shield the bacteria from the host immune system and most common antibiotic drugs, which renders them essentially antibiotic-tolerant. There is an urgent clinical need for novel strategies to prevent these serious infections that do not involve conventional antibiotics. Recently, a novel antibiofilm coating for titanium surfaces was developed based on 5-(4-bromophenyl)-N-cyclopentyl-1-octyl-1H-imidazol-2-amine as an active biofilm inhibitor. In the current study we present an optimized coating protocol that allowed for a 5-fold higher load of this active compound, whilst shortening the manufacturing process. When applied to titanium disks, the newly optimized coating was resilient to the most common sterilization procedures and it induced a 1 log reduction in biofilm cells of a clinical Staphylococcus aureus isolate (JAR060131) in vitro, without affecting the planktonic phase. Moreover, the antibiofilm effect of the coating in combination with the antibiotic cefuroxime was higher than cefuroxime treatment alone. Furthermore, the coating was successfully applied to a human-scale fracture fixation device resulting in a loading that was comparable to the titanium disk model. Finally, an in vivo biocompatibility and healing study in a rabbit osteotomy model indicated that these coated implants did not negatively affect fracture healing or osteointegration. These findings put our technology one step closer to clinical trials, confirming its potential in fighting orthopedic infections without compromising healing.
Collapse
Affiliation(s)
- Guglielmo Attilio Coppola
- KU Leuven - Department of Chemistry, Laboratory for Organic & Microwave-Assisted Chemistry (LOMAC), Leuven, Belgium.,KU Leuven - Department of Microbial and Molecular Systems, Centre of Microbial and Plant Genetics (CMPG), Leuven, Belgium
| | - Jolien Onsea
- Department of Trauma Surgery, University Hospitals Leuven, Leuven, Belgium.,KU Leuven - Department of Development and Regeneration, Leuven, Belgium
| | | | | | | | | | - Merve Kübra Aktan
- KU Leuven - Department of Materials Engineering (MTM), Biomaterials and Tissue Engineering Research Group, Leuven, Belgium
| | - Annabel Braem
- KU Leuven - Department of Materials Engineering (MTM), Biomaterials and Tissue Engineering Research Group, Leuven, Belgium
| | - Erik V Van der Eycken
- KU Leuven - Department of Chemistry, Laboratory for Organic & Microwave-Assisted Chemistry (LOMAC), Leuven, Belgium.,Peoples' Friendship University of Russia, Moscow, Russia
| | - Hans P Steenackers
- KU Leuven - Department of Microbial and Molecular Systems, Centre of Microbial and Plant Genetics (CMPG), Leuven, Belgium
| | - Willem-Jan Metsemakers
- Department of Trauma Surgery, University Hospitals Leuven, Leuven, Belgium.,KU Leuven - Department of Development and Regeneration, Leuven, Belgium
| |
Collapse
|
9
|
Tanner MC, Fischer C, Schmidmaier G, Haubruck P. Evidence-based uncertainty: do implant-related properties of titanium reduce the susceptibility to perioperative infections in clinical fracture management? A systematic review. Infection 2021; 49:813-821. [PMID: 33586124 PMCID: PMC8476472 DOI: 10.1007/s15010-021-01583-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Accepted: 02/02/2021] [Indexed: 11/28/2022]
Abstract
Background Implant-associated infections (IAI) remain a challenging complication in osteosynthesis. There is no consensus or clear evidence whether titanium offers a relevant clinical benefit over stainless steel. Purpose In this systematic review, we sought to determine whether the implant properties of titanium reduce the susceptibility to IAI compared to stainless steel in fracture management. Methods A systematic literature search in German and English was performed using specific search terms and limits. Studies published between 1995 and 1st June 2020 in the Cochrane library, MEDLINE and Web of Science databases were included. Only clinical studies comparing titanium and stainless steel implants regarding the susceptibility to infections were selected for detailed review. Results Five studies out of 384 papers were identified and reviewed. From the studies meeting inclusion criteria one study was a systematic review, two studies were randomized controlled studies (RCT) and two studies were of retrospective comparative nature of level IV evidence. Conclusion Our results show that currently, no proven advantage for titanium implants in respect to IAI can be seen in contemporary literature. Implants preserving periosteal blood-flow and minimising soft-tissue trauma show statistically significant benefits in reducing the incidence of IAI. Clinical studies providing reliable evidence regarding the influence of titanium implants on IAI and investigating the susceptibility of titanium to infection are necessary
Collapse
Affiliation(s)
- Michael C Tanner
- HTRG-Heidelberg Trauma Research Group, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Trauma and Reconstructive Surgery, Heidelberg University Hospital, 69118, Heidelberg, Germany.
| | - Christian Fischer
- HTRG-Heidelberg Trauma Research Group, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Trauma and Reconstructive Surgery, Heidelberg University Hospital, 69118, Heidelberg, Germany
| | - Gerhard Schmidmaier
- HTRG-Heidelberg Trauma Research Group, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Trauma and Reconstructive Surgery, Heidelberg University Hospital, 69118, Heidelberg, Germany
| | - Patrick Haubruck
- HTRG-Heidelberg Trauma Research Group, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Trauma and Reconstructive Surgery, Heidelberg University Hospital, 69118, Heidelberg, Germany
| |
Collapse
|
10
|
Lee SW, Phillips KS, Gu H, Kazemzadeh-Narbat M, Ren D. How microbes read the map: Effects of implant topography on bacterial adhesion and biofilm formation. Biomaterials 2020; 268:120595. [PMID: 33360301 DOI: 10.1016/j.biomaterials.2020.120595] [Citation(s) in RCA: 61] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Revised: 11/24/2020] [Accepted: 12/06/2020] [Indexed: 12/19/2022]
Abstract
Microbes have remarkable capabilities to attach to the surface of implanted medical devices and form biofilms that adversely impact device function and increase the risk of multidrug-resistant infections. The physicochemical properties of biomaterials have long been known to play an important role in biofilm formation. More recently, a series of discoveries in the natural world have stimulated great interest in the use of 3D surface topography to engineer antifouling materials that resist bacterial colonization. There is also increasing evidence that some medical device surface topographies, such as those designed for tissue integration, may unintentionally promote microbial attachment. Despite a number of reviews on surface topography and biofilm control, there is a missing link between how bacteria sense and respond to 3D surface topographies and the rational design of antifouling materials. Motivated by this gap, we present a review of how bacteria interact with surface topographies, and what can be learned from current laboratory studies of microbial adhesion and biofilm formation on specific topographic features and medical devices. We also address specific biocompatibility considerations and discuss how to improve the assessment of the anti-biofilm performance of topographic surfaces. We conclude that 3D surface topography, whether intended or unintended, is an important consideration in the rational design of safe medical devices. Future research on next-generation smart antifouling materials could benefit from a greater focus on translation to real-world applications.
Collapse
Affiliation(s)
- Sang Won Lee
- Department of Biomedical and Chemical Engineering, Syracuse University, Syracuse, NY, 13244, United States; Syracuse Biomaterials Institute, Syracuse University, Syracuse, NY, 13244, United States
| | - K Scott Phillips
- United States Food and Drug Administration, Office of Medical Products and Tobacco, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, Division of Biology, Chemistry, and Materials Science, Silver Spring, MD, 20993, United States.
| | - Huan Gu
- Department of Biomedical and Chemical Engineering, Syracuse University, Syracuse, NY, 13244, United States; Syracuse Biomaterials Institute, Syracuse University, Syracuse, NY, 13244, United States
| | - Mehdi Kazemzadeh-Narbat
- United States Food and Drug Administration, Office of Medical Products and Tobacco, Center for Devices and Radiological Health, Office of Product Evaluation and Quality, Office of Health Technology 6, Silver Spring, MD, 20993, United States; Musculoskeletal Clinical Regulatory Advisers (MCRA), Washington DC, 20001, United States
| | - Dacheng Ren
- Department of Biomedical and Chemical Engineering, Syracuse University, Syracuse, NY, 13244, United States; Syracuse Biomaterials Institute, Syracuse University, Syracuse, NY, 13244, United States; Department of Civil and Environmental Engineering, Syracuse University, Syracuse, NY, 13244, United States; Department of Biology, Syracuse University, Syracuse, NY, 13244, United States.
| |
Collapse
|
11
|
Palka L, Mazurek-Popczyk J, Arkusz K, Baldy-Chudzik K. Susceptibility to biofilm formation on 3D-printed titanium fixation plates used in the mandible: a preliminary study. J Oral Microbiol 2020; 12:1838164. [PMID: 33194115 PMCID: PMC7598999 DOI: 10.1080/20002297.2020.1838164] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Revised: 10/11/2020] [Accepted: 10/14/2020] [Indexed: 01/07/2023] Open
Abstract
Background: In the oral and maxillofacial surgery, fixation plates are commonly used for the stabilization of bone fragments. Additive manufacturing has enabled us to design and create personalized fixation devices that would ideally fit any given fracture. Aim: The aim of the present preliminary study was to assess the susceptibility of 3D-printed titanium fixation plates to biofilm formation. Methods: Plates were manufactured using selective laser melting (SLM) from Ti-6Al-4 V. Reference strains of Streptococcus mutans, Staphyloccocus epidermidis, Staphylococcus aureus, Lactobacillus rhamnosus, and Candida albicans, were tested to evaluate the material's susceptibility to biofilm formation over 48 hours. Biofilm formations were quantified by a colorimetric method and colony-forming units (CFU) quantification. Scanning electron microscopy (SEM) visualized the structure of the biofilm. Results: Surface analysis revealed the average roughness of 102.75 nm and irregular topography of the tested plates. They were susceptible to biofilm formation by all tested strains. The average CFUs were as follows: S. mutans (11.91 x 107) > S.epidermidis (4.45 x 107) > S. aureus (2.3 x 107) > C.albicans (1.22 x 107) > L. rhamnosus (0.78 x 107). Conclusions: The present preliminary study showed that rough surfaces of additively manufactured titanium plates are susceptible to microbial adhesion. The research should be continued in order to compare additively manufactured plates with other commercially available osteotomy plates. Therefore, we suggest caution when using this type of material.
Collapse
Affiliation(s)
- Lukasz Palka
- Private Dental Practice, Zary, Poland
- ScienceBioTech, Wrocław, Poland
| | - Justyna Mazurek-Popczyk
- Department of Microbiology and Molecular Biology, Institute of Health Sciences, Collegium Medicum, University of Zielona Góra, Zielona Góra, Poland
| | - Katarzyna Arkusz
- Department of Biomedical Engineering, Institute of Materials and Biomedical Engineering, Faculty of Mechanical Engineering, University of Zielona Góra, Zielona Góra, Poland
| | - Katarzyna Baldy-Chudzik
- Department of Microbiology and Molecular Biology, Institute of Health Sciences, Collegium Medicum, University of Zielona Góra, Zielona Góra, Poland
| |
Collapse
|
12
|
Donati B, Fürst AE, Del Chicca F, Jackson MA. Plate Removal after Internal Fixation of Limb Fractures: A Retrospective Study of Indications and Complications in 48 Horses. Vet Comp Orthop Traumatol 2020; 34:59-67. [PMID: 32799311 DOI: 10.1055/s-0040-1714411] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVE The aim of this study was to determine the indications for, and complications of, plate removal surgery in horses that underwent internal fixation of limb fractures. STUDY DESIGN Medical records of horses presented to our hospital between 1990 and 2015 for the removal of plates after treatment of limb fractures were reviewed. Data collected at the time of initial presentation, including signalment, history, fracture features and treatment and information about the indications, timing and complications of implant removal were reviewed. RESULTS The most common bones involved were the ulna (n = 19) and third metacarpal and metatarsal bones (n = 14). A total of 63 plates were removed from 48 horses during 53 separate surgeries, and the complication rate was 6/48; six horses had complications related to implant removal, which included persistent infection (n = 1) and refracture (n = 5). Complications related to implant removal were associated with comminuted fractures (p = 0.002), age > 3 years (p = 0.016) and the presence of surgical site infection (p = 0.001). CONCLUSION Plate removal after fracture healing is necessary in patients with implant-associated clinical signs. There is a strong relationship between the complication rate and the degree of comminution of the original fracture, increasing age and the presence of surgical site infection. The surgeon must be aware of these risk factors when planning plate removal.
Collapse
Affiliation(s)
- Brice Donati
- Equine Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | - Anton E Fürst
- Equine Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | - Francesca Del Chicca
- Department of Small Animals, Section of Diagnostic Imaging, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | - Michelle A Jackson
- Equine Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| |
Collapse
|
13
|
Local Application of a Gentamicin-Loaded Hydrogel Early After Injury Is Superior to Perioperative Systemic Prophylaxis in a Rabbit Open Fracture Model. J Orthop Trauma 2020; 34:231-237. [PMID: 32304564 DOI: 10.1097/bot.0000000000001707] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVES Open fractures are at significant risk of developing a fracture-related infection, despite the routine administration of perioperative antibiotic prophylaxis. Early application of antibiotic prophylaxis is known to reduce infection rates; however, most international guidelines focus on postoperative duration rather than prehospital administration. We compared conventional perioperative prophylaxis against early prehospital prophylaxis either as a systemic single shot of cefuroxime or a locally applied gentamicin-loaded hydrogel in a laboratory animal model. METHODS Thirty New Zealand white rabbits underwent a first surgical procedure to create an open wound, bone damage and contamination with Staphylococcus aureus. After a 4-hour observation period mimicking the time-to-treatment, the animals underwent a second procedure to irrigate the wound and apply a fracture fixation device. The 5 groups (n = 6 per group) received (1) no treatment; (2) conventional 24-hour cefuroxime; (3) an early single shot of cefuroxime 15 minutes after trauma; (4) a combined early and standard systemic prophylaxis; and (5) early application of a gentamicin-loaded hydrogel that was removed during irrigation. RESULTS Untreated animals displayed high numbers of bacteria in irrigation fluid and were all highly culture positive at euthanasia. Three of 6 animals were culture positive at euthanasia after conventional prophylaxis. Early systemic prophylaxis reduced bacterial burden in irrigation fluid by up to 100-fold, but 5/6 animals were culture positive at euthanasia. The combined prophylaxis displayed greater efficacy with only 1/6 rabbits culture positive at euthanasia. Local application of the gentamicin-loaded hydrogel reduced bacteria recovered by irrigation to just above our detection limit, and at euthanasia, all animals were culture negative at euthanasia. CONCLUSIONS Early systemic antibiotic administration can significantly reduce bacterial burden in the operative field and reduce culture positivity at euthanasia when continued for 24 hours after injury. The early application of a gentamicin-loaded hydrogel that was removed during irrigation displayed superior efficacy to early systemic therapy alone and postoperative conventional gold standard 24-hour systemic therapy alone. These experimental results highlight the importance of early antibiotic administration in fracture care.
Collapse
|
14
|
Foster AL, Moriarty TF, Trampuz A, Jaiprakash A, Burch MA, Crawford R, Paterson DL, Metsemakers WJ, Schuetz M, Richards RG. Fracture-related infection: current methods for prevention and treatment. Expert Rev Anti Infect Ther 2020; 18:307-321. [DOI: 10.1080/14787210.2020.1729740] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Andrew L Foster
- AO Research Institute Davos, Davos, Switzerland
- Faculty of Science and Engineering, Queensland University of Technology (QUT), Brisbane, Australia
- Department of Orthopaedic Surgery, Royal Brisbane and Women’s Hospital, Queensland, Australia
- Jamieson Trauma Institute, Royal Brisbane and Women’s Hospital, Queensland, Australia
| | | | - Andrej Trampuz
- Center for Musculoskeletal Surgery, Septic Unit Charité-Universitätsmedizin, Berlin, Germany
| | - Anjali Jaiprakash
- Faculty of Science and Engineering, Queensland University of Technology (QUT), Brisbane, Australia
| | | | - Ross Crawford
- Faculty of Science and Engineering, Queensland University of Technology (QUT), Brisbane, Australia
| | - David L Paterson
- University of Queensland Centre of Clinical Research (UQCCR), Brisbane, Australia
| | - Willem-Jan Metsemakers
- Department of Trauma Surgery, University Hospitals Leuven, Belgium
- Department of Development and Regeneration, KU Leuven, Belgium
| | - Michael Schuetz
- Faculty of Science and Engineering, Queensland University of Technology (QUT), Brisbane, Australia
- Department of Orthopaedic Surgery, Royal Brisbane and Women’s Hospital, Queensland, Australia
- Jamieson Trauma Institute, Royal Brisbane and Women’s Hospital, Queensland, Australia
| | | |
Collapse
|
15
|
Pazarci O, Tutar U, Kilinc S. Investigation of the Antibiofilm Effects of Mentha longifolia Essential Oil on Titanium and Stainless Steel Orthopedic Implant Surfaces. Eurasian J Med 2019; 51:128-132. [PMID: 31258351 DOI: 10.5152/eurasianjmed.2019.18432] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Objective This study aimed to determine the antibiofilm activity of Mentha longifolia essential oil (EO) against biofilms forming on in-vitro implant surfaces. Materials and Methods Enterococcus faecalis, Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa, Klebsiella pneumoniae, and Candida albicans biofilms were used. Stainless steel and titanium samples were grouped as control, water diluted, no EO addition, and reducing amounts of EO doses. The six microorganisms included in the study were investigated to examine if there were differences between the doses on the implant surfaces. The eradication effect of the EO in samples investigated with electron microscope was classified as 0: none, 1: mild, 2: moderate, and 3: severe. The chemical composition of the EO was determined with gas chromatography. Results In terms of biofilm formation, no difference was observed between implant surfaces. While S. aureus and C. albicans were observed to be the most susceptible, P. aeruginosa was identified as the most resistant. According to gas chromatography, M. longifolia EO comprised 61.40% carvacrol and 0.28% thymol. Conclusion In vitro, M. longifolia EO was shown to be effective against gram negative/positive and fungal biofilms forming on the surface of stainless steel and titanium implants.
Collapse
Affiliation(s)
- Ozhan Pazarci
- Department of Orthopaedics and Traumatology, Cumhuriyet University School of Medicine, Sivas, Turkey
| | - Ugur Tutar
- Department of Nutrition and Dietetics, Cumhuriyet University of Health Sciences, Sivas, Turkey
| | - Seyran Kilinc
- Department of Orthopaedics and Traumatology, Cumhuriyet University School of Medicine, Sivas, Turkey
| |
Collapse
|
16
|
Abstract
There is a significant burden of disease associated with infected fractures, and their management is challenging. Prevention of infection after musculoskeletal trauma is essential because treatment of an established infection continues to be a major obstacle. Despite the need for evidence-based decision making, there is a lack of consensus around strategies for prevention and surgical management of the infected fracture. The current evidence for the prevention of the infected fracture is reviewed here with a focus on evidence for antibiotic therapy and debridement, the induced membrane technique, management of soft-tissue defects, patient optimization, and adjuncts to prevent infection.
Collapse
|
17
|
Abstract
Orthopedic disorders are a common clinical presentation for the exotic clinician. Before treating the fracture it is vital to stabilize the patient. Small exotic mammals are characterized by relatively thinner bones, adding to the difficulty the small size already represents. A combination of conservative and surgical treatment options are available. The principles of orthopedic surgery and ideas behind the treatment options remain the same as for small mammals, but not all techniques can be directly extrapolated. Historically, the tie-in fixator has been the preferred surgical choice whenever feasible, but further development in bone plates represents a promising advancement.
Collapse
Affiliation(s)
- Yasutsugu Miwa
- Miwa Exotic Animal Hospital, 1-25-5 Komagome, Toshima-ku, Tokyo 170-0003A, Japan; Laboratories of Veterinary Surgery, Graduate School of Agricultural and Life Sciences, The University of Tokyo, 1-1-1 Yayoi, Bunkyo-ku, Tokyo 113-8657, Japan
| | - Daniel Calvo Carrasco
- Great Western Exotics, Vets Now Swindon, Swindon, UK; Wildfowl & Wetlands Trust (WWT), Newgrounds Ln, Gloucestershire, England, Gloucester GL2 7BT, United Kingdom.
| |
Collapse
|
18
|
McEvoy JP, Martin P, Khaleel A, Dissanayeke S. Titanium Kirschner Wires Resist Biofilms Better Than Stainless Steel and Hydroxyapatite-coated Wires: An In Vitro Study. Strategies Trauma Limb Reconstr 2019; 14:57-64. [PMID: 32742415 PMCID: PMC7376582 DOI: 10.5005/jp-journals-10080-1426] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Aim External fixation surgery is frequently complicated by percutaneous pin site infection focused on the surface of the fixator pin. The primary aim of this study was to compare biofilm growth of clinically isolated pin site bacteria on Kirschner wires of different materials. Materials and methods Two commonly infecting species, Staphylococcus epidermidis and Proteus mirabilis, were isolated from patients’ pin sites. A stirred batch bioreactor was used to grow these bacteria as single culture and co-cultured biofilms on Kirschner wires made of three different materials: stainless steel, hydroxyapatite-coated steel and titanium alloy. Results We found that the surface density of viable cells within these biofilms was 3x higher on stainless steel and 4.5x higher on hydroxyapatite-coated wires than on the titanium wires. Conclusion Our results suggest that the lower rates of clinical pin site infection seen with titanium Kirschner wires are due to, at least in part, titanium’s better bacterial biofilm resistance. Clinical significance Our results are consistent with clinical studies which have found that pin site infection rates are reduced by the use of titanium relative to stainless steel or hydroxyapatite-coated pins. How to cite this article McEvoy JP, Martin P, Khaleel A, et al. Titanium Kirschner Wires Resist Biofilms Better Than Stainless Steel and Hydroxyapatite-coated Wires: An In Vitro Study. Strategies Trauma Limb Reconstr 2019;14(2):57–64.
Collapse
Affiliation(s)
- James P McEvoy
- Department of Biological Sciences, Royal Holloway, University of London, Egham, Surrey, UK
| | - Philip Martin
- Department of Biological Sciences, Royal Holloway, University of London, Egham, Surrey, UK
| | - Arshad Khaleel
- Rowley Bristow Orthopaedic Unit, Ashford and St Peter's Hospitals NHS Foundation Trust, Chertsey, Surrey, UK
| | - Shobana Dissanayeke
- Department of Biological Sciences, Royal Holloway, University of London, Egham, Surrey, UK
| |
Collapse
|
19
|
Moriarty TF, Harris LG, Mooney RA, Wenke JC, Riool M, Zaat SAJ, Moter A, Schaer TP, Khanna N, Kuehl R, Alt V, Montali A, Liu J, Zeiter S, Busscher HJ, Grainger DW, Richards RG. Recommendations for design and conduct of preclinical in vivo studies of orthopedic device-related infection. J Orthop Res 2019; 37:271-287. [PMID: 30667561 DOI: 10.1002/jor.24230] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Accepted: 12/06/2018] [Indexed: 02/04/2023]
Abstract
Orthopedic device-related infection (ODRI), including both fracture-related infection (FRI) and periprosthetic joint infection (PJI), remain among the most challenging complications in orthopedic and musculoskeletal trauma surgery. ODRI has been convincingly shown to delay healing, worsen functional outcome and incur significant socio-economic costs. To address this clinical problem, ever more sophisticated technologies targeting the prevention and/or treatment of ODRI are being developed and tested in vitro and in vivo. Among the most commonly described innovations are antimicrobial-coated orthopedic devices, antimicrobial-loaded bone cements and void fillers, and dual osteo-inductive/antimicrobial biomaterials. Unfortunately, translation of these technologies to the clinic has been limited, at least partially due to the challenging and still evolving regulatory environment for antimicrobial drug-device combination products, and a lack of clarity in the burden of proof required in preclinical studies. Preclinical in vivo testing (i.e. animal studies) represents a critical phase of the multidisciplinary effort to design, produce and reliably test both safety and efficacy of any new antimicrobial device. Nonetheless, current in vivo testing protocols, procedures, models, and assessments are highly disparate, irregularly conducted and reported, and without standardization and validation. The purpose of the present opinion piece is to discuss best practices in preclinical in vivo testing of antimicrobial interventions targeting ODRI. By sharing these experience-driven views, we aim to aid others in conducting such studies both for fundamental biomedical research, but also for regulatory and clinical evaluation. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:271-287, 2019.
Collapse
Affiliation(s)
- T Fintan Moriarty
- AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos Platz, Switzerland
| | - Llinos G Harris
- Microbiology and Infectious Diseases, Institute of Life Science, Swansea University Medical School, Swansea, United Kingdom
| | - Robert A Mooney
- Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, New York
| | - Joseph C Wenke
- Extremity Trauma and Regenerative Medicine Task Area, US Army Institute of Surgical Research, JBSA-Fort Sam Houston, Texas
| | - Martijn Riool
- Amsterdam UMC, University of Amsterdam, Department of Medical Microbiology, Amsterdam Infection and Immunity Institute, Amsterdam, The Netherlands
| | - Sebastian A J Zaat
- Amsterdam UMC, University of Amsterdam, Department of Medical Microbiology, Amsterdam Infection and Immunity Institute, Amsterdam, The Netherlands
| | - Annette Moter
- Institute of Microbiology and Infection Immunology, Charité Universitätsmedizin Berlin, Berlin, Germany
| | - Thomas P Schaer
- Department of Clinical Studies New Bolton Center, University of Pennsylvania, Kennett Square, Pennsylvania
| | - Nina Khanna
- Infection Biology Laboratory, Department of Biomedicine, University Hospital of Basel, Basel, Switzerland.,Division of Infectious Diseases and Hospital Epidemiology, University Hospital of Basel, Basel, Switzerland
| | - Richard Kuehl
- Infection Biology Laboratory, Department of Biomedicine, University Hospital of Basel, Basel, Switzerland.,Division of Infectious Diseases and Hospital Epidemiology, University Hospital of Basel, Basel, Switzerland
| | - Volker Alt
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Giessen-Marburg, GmbH, Campus Giessen, Germany
| | | | - Jianfeng Liu
- Tianjin Key Laboratory of Radiation Medicine and Molecular Nuclear Medicine, Institute of Radiation Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, P.R. China
| | - Stephan Zeiter
- AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos Platz, Switzerland
| | - Henk J Busscher
- Department of Biomedical Engineering, University of Groningen and University Medical Center Groningen, Groningen, The Netherlands
| | - David W Grainger
- Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, USA.,Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, Salt Lake City, Utah, USA
| | - R Geoff Richards
- AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos Platz, Switzerland
| |
Collapse
|
20
|
Rochford ETJ, Sabaté Brescó M, Poulsson AHC, Kluge K, Zeiter S, Ziegler M, O'Mahony L, Richards RG, Moriarty TF. Infection burden and immunological responses are equivalent for polymeric and metallic implant materials in vitro and in a murine model of fracture-related infection. J Biomed Mater Res B Appl Biomater 2018; 107:1095-1106. [PMID: 30332531 DOI: 10.1002/jbm.b.34202] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2017] [Revised: 01/30/2018] [Accepted: 02/18/2018] [Indexed: 12/31/2022]
Abstract
The development of an infection is a major complication for some patients with implanted biomaterials. Whether the material or surface composition of the used biomaterial influences infection has not been directly compared for key biomaterials currently in use in human patients. We conducted a thorough in vitro and in vivo investigation using titanium (Ti) and polyether-ether-ketone (PEEK) as both commercially available and as modified equivalents (surface polished Ti, and oxygen plasma treated PEEK). Complement activation and cytokine secretion of cell of the immune system was assessed in vitro for all materials in the absence and presence of bacterial stimulants. In a follow-up in vivo study, we monitored bacterial infection associated with clinically available and standard Ti and PEEK inoculated with Staphylococcus aureus. Complement activation was affected by material choice in the absence of bacterial stimulation, although the material based differences were largely lost upon bacterial stimulation. In the in vivo study, the bacterial burden, histological response and cytokine secretion suggests that there is no significant difference between both PEEK and Ti. In conclusion, the underlying material has a certain impact in the absence of bacterial stimulation, however, in the presence of bacterial stimulation, bacteria seem to dictate the responses in a manner that overshadows the influence of material surface properties. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1095-1106, 2019.
Collapse
Affiliation(s)
| | | | | | | | | | - Mario Ziegler
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos, Switzerland
| | - Liam O'Mahony
- Departments of Medicine and Microbiology, APC Microbiome Ireland, National University of Ireland, Cork, Ireland
| | | | | |
Collapse
|
21
|
Antibiotic Prophylaxis With Cefuroxime: Influence of Duration on Infection Rate With Staphylococcus aureus in a Contaminated Open Fracture Model. J Orthop Trauma 2018; 32:190-195. [PMID: 29558373 DOI: 10.1097/bot.0000000000001053] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVES The optimal duration of perioperative antibiotic prophylaxis (PAP) for open fractures remains controversial because of heterogeneous or unclear guidelines and highly variable prophylactic regimens in clinical practice. We aimed at testing different PAP durations under controlled conditions in a contaminated rabbit fracture model. METHODS A complete humeral osteotomy in 18 rabbits was fixed with a 7-hole locking compression plate and inoculated with Staphylococcus aureus. Cefuroxime was administered in a weight-adjusted dosage equivalent to human medicine (18.75 mg/kg). PAP was administered as a single shot only; for 24 hours; or for 72 hours in separate groups of rabbits (n = 6 per group). Infection was assessed after 2 weeks by quantitative bacteriological evaluation of the tissues and hardware. RESULTS Postoperative duration of PAP had a significant impact on the success of antibiotic prophylaxis in this model. Whereas the single-shot regimen completely failed to prevent infection, the 24-hour regimen showed a reduced infection rate (1 of 6 rabbits infected), but only the 72-hour course was able to prevent fracture-related infection in all animals in our model. CONCLUSIONS When contamination with high bacterial loads is likely (eg, in an open fracture situation), a 72-hour course of intravenous cefuroxime seems to be superior in preventing fracture-related infection in our rabbit model compared with a single-shot or 24-hour antibiotic regimen.
Collapse
|
22
|
Metsemakers WJ, Kuehl R, Moriarty TF, Richards RG, Verhofstad MHJ, Borens O, Kates S, Morgenstern M. Infection after fracture fixation: Current surgical and microbiological concepts. Injury 2018; 49:511-522. [PMID: 27639601 DOI: 10.1016/j.injury.2016.09.019] [Citation(s) in RCA: 276] [Impact Index Per Article: 46.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2016] [Accepted: 09/08/2016] [Indexed: 02/02/2023]
Abstract
One of the most challenging complications in trauma surgery is infection after fracture fixation (IAFF). IAFF may result in permanent functional loss or even amputation of the affected limb in patients who may otherwise be expected to achieve complete, uneventful healing. Over the past decades, the problem of implant related bone infections has garnered increasing attention both in the clinical as well as preclinical arenas; however this has primarily been focused upon prosthetic joint infection (PJI), rather than on IAFF. Although IAFF shares many similarities with PJI, there are numerous critical differences in many facets including prevention, diagnosis and treatment. Admittedly, extrapolating data from PJI research to IAFF has been of value to the trauma surgeon, but we should also be aware of the unique challenges posed by IAFF that may not be accounted for in the PJI literature. This review summarizes the clinical approaches towards the diagnosis and treatment of IAFF with an emphasis on the unique aspects of fracture care that distinguish IAFF from PJI. Finally, recent developments in anti-infective technologies that may be particularly suitable or applicable for trauma patients in the future will be briefly discussed.
Collapse
Affiliation(s)
- W J Metsemakers
- Department of Trauma Surgery, University Hospitals Leuven, Belgium.
| | - R Kuehl
- Division of Infectious Diseases and Hospital Epidemiology, University Hospital of Basel, Switzerland
| | | | | | - M H J Verhofstad
- Department of Trauma Surgery, Erasmus University Medical Centre, Rotterdam, The Netherlands, The Netherlands
| | - O Borens
- Orthopedic Septic Surgical Unit, Department of the Locomotor Apparatus and Department of Surgery and Anaesthesiology, Lausanne University Hospital, Lausanne, Switzerland
| | - S Kates
- Department of Orthopaedic Surgery, Virginia Commonwealth University, USA
| | - M Morgenstern
- Department of Orthopaedic and Trauma Surgery, University Hospital of Basel, Switzerland
| |
Collapse
|
23
|
Ieropoli G, Villafañe JH, Zompi SC, Morozzo U, D'Ambrosi R, Usuelli FG, Berjano P. Successful treatment of infected wound dehiscence after minimally invasive locking-plate osteosynthesis of tibial pilon and calcaneal fractures by plate preservation, surgical debridement and antibiotics. Foot (Edinb) 2017; 33:44-47. [PMID: 29126042 DOI: 10.1016/j.foot.2017.10.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2017] [Revised: 08/07/2017] [Accepted: 10/19/2017] [Indexed: 02/04/2023]
Abstract
OBJECTIVE The aim is to present a case series that illustrates possible benefits from combining minimally invasive plate osteosynthesis (MIPO), plastic surgery and antibiotic therapy, in order to treat and eradicate infection in patients with tibial pilon or calcaneal fractures. METHODS Eleven consecutive patients with dehiscence of the surgical wound in outcomes MIPO using a Locking Compression Plate (LCP) for tibial pilon, or calcaneus fractures. The patients had developed a documented infection of the surgical wound. All patients were treated and followed-up by the multidisciplinary team with the orthopedic surgeon, the plastic surgeon and the infectious disease physician. All patients were followed by the plastic surgeon to treat the wound dehiscence, as well as by the orthopedic surgeon until fracture consolidation. The duration of the antibiotic therapy was from 4 to 6 months. After 6 weeks, the intravenous treatment was replaced by oral administration. The follow-up intervals were 15 days, 40 days, and 3 months. RESULTS The average time of wound closure was 109±60 days. The antibiotics used were chosen according to the antibiogram. The antibiotic therapy had a duration of 4-6 months, and after 6 weeks, the therapy switched to oral administration. At the 3-month follow-up, all patients had excellent outcomes and had returned to their normal activity of daily living. CONCLUSION The patients in this study responded positively to a combination of MIPO, plastic surgery and antibiotic therapy, confirming that multidisplinary treatment in association with titanium devices are able to eradicate infection in short time.
Collapse
|
24
|
Haubruck P, Schmidmaier G. [Susceptibility to infections and behavior of stainless steel : Comparison with titanium implants in traumatology]. Unfallchirurg 2017; 120:110-115. [PMID: 28070629 DOI: 10.1007/s00113-016-0300-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Despite modern treatment options, implant-associated infections (IAI) remain a severe and challenging complication in the treatment of trauma patients. Almost 30 years after the introduction of implants made of titanium alloy into the treatment of trauma patients, there is still no uniform consensus regarding the clinical benefit of titanium alloy in the context of patients with IAI. OBJECTIVE We sought to determine if implants made of titanium alloy have been proven to be less susceptible regarding IAI in contrast to implants made of stainless steel. MATERIAL AND METHODS A review of the current literature on IAI in association with the utilized implant material was conducted. Relevant articles from the years 1995 to 2016 were searched in the PubMed database. A total of 183 articles were identified and all abstracts were reviewed for relevance. A total of 14 articles met the inclusion criteria and were stratified according to the level of evidence and furthermore evaluated regarding the influence of the implant material on IAI. RESULTS AND DISCUSSION Considerable debate remains concerning the influence of the implant material on the susceptibility to IAI; however, the available literature shows that despite slight tendencies, there is no proof of titanium alloy being favorable in the susceptibility to IAI. Furthermore, the literature shows that the design of plates for osteosynthesis might influence IAI. In particular, plates that cause less soft tissue damage and preserve perfusion of the periosteum proved to be beneficial regarding IAI.
Collapse
Affiliation(s)
- Patrick Haubruck
- Klinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Heidelberg, Schlierbacher Landstraße 200a, 69118, Heidelberg, Deutschland
| | - Gerhard Schmidmaier
- Klinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Heidelberg, Schlierbacher Landstraße 200a, 69118, Heidelberg, Deutschland.
| |
Collapse
|