1
|
Wang HR, Li J, Zhang LF, Li DM, Han B, Li B, Li JR, Li LG. Biomechanical analysis of fixation strength at different nailing angles for femoral neck fracture with insufficient reduction. Comput Methods Biomech Biomed Engin 2024; 27:1949-1959. [PMID: 37842737 DOI: 10.1080/10255842.2023.2265010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 09/21/2023] [Accepted: 09/24/2023] [Indexed: 10/17/2023]
Abstract
To analyze the fixation strength of cannulated screws fixation in the treatment of femoral neck fracture with posterior tilt due to insufficient reduction. Two sets of digital models of anatomical reduction and 15° tilting reduction were established by CT data. Each group of models was modeled with two different fixation methods. One fixation method was fixed according to the standard cannulated screws recommended by AO. Another fixation method is to tilt the screw posterior tilt 15°. The final four groups of models were obtained: AO principle nailing posterior tilt model (Group A), posterior direction nailing posterior tilt model (Group B), AO principle nailing anatomic reduction model (Group C) and posterior direction nailing anatomic reduction model (Group D). The maximum displacement of the fracture end, the maximum Von-Mises stress and the stress distribution of the internal fixation were compared among the four groups. Four groups of models were established on artificial bone by 3D printing guide plate technology. The 600 N pressure test and yield test were performed on a biomechanical machine. The finite element and biomechanical models showed that groups B and C were more stable than groups A and D. The stability of group B was not worse than that of group C. When the femoral neck fracture produces a posterior tilt, a posterior reduction is allowed. The change of AO screw to posterior tilting screw fixation has more powerful advantages. No posterior tilt or posterior reduction, AO screw placement is still required.
Collapse
Affiliation(s)
- Hong-Run Wang
- Institute of Trauma Surgery, The Second Hospital of Tangshan, Tangshan, Hebei Province, China
| | - Ji Li
- Institute of Trauma Surgery, The Second Hospital of Tangshan, Tangshan, Hebei Province, China
| | - Li-Feng Zhang
- Institute of Trauma Surgery, The Second Hospital of Tangshan, Tangshan, Hebei Province, China
| | - Dong-Mei Li
- Institute of Trauma Surgery, The Second Hospital of Tangshan, Tangshan, Hebei Province, China
| | - Biao Han
- Institute of Trauma Surgery, The Second Hospital of Tangshan, Tangshan, Hebei Province, China
| | - Bin Li
- Institute of Trauma Surgery, The Second Hospital of Tangshan, Tangshan, Hebei Province, China
| | - Jun-Ran Li
- Institute of Trauma Surgery, The Second Hospital of Tangshan, Tangshan, Hebei Province, China
| | - Li-Geng Li
- Institute of Trauma Surgery, The Second Hospital of Tangshan, Tangshan, Hebei Province, China
| |
Collapse
|
2
|
Kulkarni GS, Kulkarni S, Malve S, Kulkarni V, Kulkarni M, Kulkarni S, Kulkarni M, Kulkarni R. Pilot study of three novel implants-GSK triangular system, locking hip screw and controlled sliding dynamic hip screw, for fixation of fracture of the neck of femur. Injury 2024; 55 Suppl 2:111594. [PMID: 39098789 DOI: 10.1016/j.injury.2024.111594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 04/25/2024] [Accepted: 04/27/2024] [Indexed: 08/06/2024]
Abstract
BACKGROUND AND OBJECTIVE Intra capsular fracture of the neck of femur (FNF) treated traditionally with a dynamic hip screw (DHS) or three cancellous screws (3CS) has a high incidence of complications with reoperation rates between 20 % and 45 %. We hypothesized that FNF unites by primary healing. Therefore, intra-operative compression and absolute stability post-operatively until healing are essential. We postulated that FNF requires 2 types of implants- those which provide absolute stability for young patients with good bone stock and another with sliding mechanism for elderly patients with osteoporosis. We developed three novel fixation systems at our research institute in India using a modified DHS. In patients with good bone stock, locking DHS, called LHS and GSK triangular system (GSKT) provided intra-operative compression and absolute stability during the post-operative period. In those with poor bone stock, the controlled sliding DHS (CSDHS)was used as a locking implant might penetrate the hip joint. MATERIALS AND METHOD 42 patients of FNF <55 years of age were studied. Among 39 patients with good bone stock, LHS was used in five patients and GSKT system was used in 34 patients. CSDHS was used in three patients with poor bone stock or communition. The patients were followed up for a minimum of eight months up to a maximum of two years, with the average follow up duration of 14 months. RESULTS 32 out of 34 fractures treated by GSKT system united. Five cases managed by LHS and three by CSDHS, all united. The union rate was 95.2 %. Of the two failed cases, one patient had nonunion (NU), the other had deep infection. Avascular necrosis of the head (AVN) was detected in three patients treated with GSKT system in the second year following surgery. Two of them had hip pain while one was asymptomatic. Eight cases of FNF Pauwels type III underwent a primary valgus osteotomy. All of them united without complications. CONCLUSION In patients with good bone stock, LHS and GSKT system allowed intra-operative compression and absolute post-operative stability without sliding of head fragment as the triangle construct is biomechanically the strongest. When bones are osteoporotic, a CSDHS provided controlled sliding (1 to 5 mm only). This pilot study showed a promising success rate of 95.2 %. We propose that the GSKT system may be used to treat intertrochanteric and other metaphyseal fractures as well. Further biomechanical studies are underway to strenghten the evidence needed for the widespread use of these implants.
Collapse
Affiliation(s)
- G S Kulkarni
- Department of Orthopaedics, P.G.I Swasthiyog Pratishthan, Miraj, Maharashtra, India.
| | - Sunil Kulkarni
- Department of Orthopaedics, P.G.I Swasthiyog Pratishthan, Miraj, Maharashtra, India
| | - Shekhar Malve
- Department of Orthopaedics, P.G.I Swasthiyog Pratishthan, Miraj, Maharashtra, India
| | - Vidisha Kulkarni
- Department of Orthopaedics, P.G.I Swasthiyog Pratishthan, Miraj, Maharashtra, India
| | - Madhura Kulkarni
- Department of Orthopaedics, P.G.I Swasthiyog Pratishthan, Miraj, Maharashtra, India
| | - Sujay Kulkarni
- Department of Orthopaedics, P.G.I Swasthiyog Pratishthan, Miraj, Maharashtra, India
| | - Milind Kulkarni
- Department of Orthopaedics, P.G.I Swasthiyog Pratishthan, Miraj, Maharashtra, India
| | - Ruta Kulkarni
- Department of Orthopaedics, P.G.I Swasthiyog Pratishthan, Miraj, Maharashtra, India
| |
Collapse
|
3
|
Kim JW, Park JW, Kim HJ, Kim TY, Yoo JI, Lee YK, Jang BW. Comparison of the Surgical Outcome between the Multiple Screw Fixation and Fixed Angle Devices for the Basicervical Femoral Neck Fractures. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:680. [PMID: 38792863 PMCID: PMC11123322 DOI: 10.3390/medicina60050680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 04/15/2024] [Accepted: 04/17/2024] [Indexed: 05/26/2024]
Abstract
Introduction: Basicervical femoral neck fracture (FNF) is an uncommon type of femoral neck fracture and is associated with an increased risk of fixation failure due to its inherent instability. The purpose of this study was to compare the surgical parameters and reoperation rate between the use of a multiple cannulated screw (MCS) and fixed angle device (FAD) in treating basicervical FNFs. Methods: We retrospectively reviewed the records of 885 patients who underwent internal fixation between May 2004 and August 2019 to determine basicervical FNF with at least 12 months of follow-up. Among the identified 77 patients with basicervical FNF, 17 patients who underwent multiple cannulated screw (MCS) fixation and 36 patients who underwent fixed angle device (FAD) fixation were included. We compared the rates of fracture-site collapse and reoperations according to the fixation device. Results: Among the 53 patients with basicervical FNF, 13 patients (24.5%) sustained surgical complications (8 collapses of fracture site and 5 reoperations). The reoperation rate in the MCS group was significantly higher than that in the FAD group (23.5% vs. 2.8%, p = 0.016), without any significant difference in the collapse of the fracture site (11.8% vs. 16.7%, p = 0.642). Conclusions: Although basicervical FNF was rare among hip fractures, fracture site collapse was prevalent and prone to fixation failure. Surgeons should keep this in mind, and consider FAD for basicervical FNF.
Collapse
Affiliation(s)
- Jin-Woo Kim
- Department of Orthopaedic Surgery, Nowon Eulji Medical Center, Seoul 01830, Republic of Korea; (J.-W.K.); (H.-J.K.)
| | - Jung-Wee Park
- Department of Orthopaedic Surgery, Seoul National Bundang Hospital, Seongnam-si 13620, Republic of Korea; (J.-W.P.); (Y.-K.L.)
| | - Hyo-Jung Kim
- Department of Orthopaedic Surgery, Nowon Eulji Medical Center, Seoul 01830, Republic of Korea; (J.-W.K.); (H.-J.K.)
| | - Tae-Young Kim
- Department of Orthopaedic Surgery, Konkuk University Hospital, Seoul 05030, Republic of Korea;
| | - Jun-Il Yoo
- Department of Orthopedic Surgery, Inha University Hospital, Inha University College of Medicine, Incheon 22332, Republic of Korea;
| | - Young-Kyun Lee
- Department of Orthopaedic Surgery, Seoul National Bundang Hospital, Seongnam-si 13620, Republic of Korea; (J.-W.P.); (Y.-K.L.)
| | - Byung-Woong Jang
- Department of Orthopaedic Surgery, Soonchunhyang University Seoul Hospital, Seoul 04401, Republic of Korea
| |
Collapse
|
4
|
Pearce AN, Sieber FE, Wang NY, Stambough JB, Stronach BM, Mears SC. Leg Length Discrepancy After Hip Fracture Repair is Associated With Reduced Gait Speed. Geriatr Orthop Surg Rehabil 2023; 14:21514593231186724. [PMID: 37435442 PMCID: PMC10331100 DOI: 10.1177/21514593231186724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 06/20/2023] [Indexed: 07/13/2023] Open
Abstract
Introduction A negative correlation exists between functional outcomes and leg length discrepancy (LLD) following hip fracture repair. We have assessed the effects of LLD following hip fracture repair in elderly patients on 3-meter walking time, standing time, activities of daily living (ADL), and instrumental activities of daily living (IADL). Methods One hundred sixty-nine patients enrolled in the STRIDE trial were identified with femoral neck, intertrochanteric, and subtrochanteric fractures that were treated with partial hip replacement, total hip replacement, cannulated screws, or intramedullary nail. Baseline patient characteristics recorded included age, sex, body mass index Charlson comorbidity index (CCI) score. ADL, IADL, grip strength, sit-to-stand time, 3-meter walking time and return to ambulation status were measured at 1 year after surgery. LLD was measured on final follow-up radiographs by either the sliding screw telescoping distance or the difference from a trans-ischial line to the lesser trochanters, and was analyzed as a continuous variable using regression analysis. Results Eighty eight patients (52%) had LLD <5 mm, 55 (33%) between 5-10 mm and 26 subjects (15%) >10 mm. Age, sex, BMI, Charlson score, and ambulation status had no significant impact on LLD occurrence. Type of procedure and fracture type did not correlate with severity of LLD. Having a larger LLD was not found to have a significant impact on post-operative ADL (P = .60), IADL (P = .08), sit-to-stand time (P = .90), grip strength (P = .14) and return to former ambulation status (P = .60), but did have a statistically significant impact on 3-meter walking time (P = .006). Discussion LLD after hip fracture was associated with reduced gait speed but did not affect many parameters associated with recovery. Continued efforts to restore leg length after hip fracture repair are likely to be beneficial.
Collapse
Affiliation(s)
- Alexa N. Pearce
- Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Frederick E. Sieber
- Department of Anesthesiology, Johns Hopkins Bayview Medical Center, Baltimore, MD, USA
| | - Nae-Yuh Wang
- Departments of Medicine, Biostatistics, and Epidemiology, Welch Center for Prevention, Epidemiology, and Clinical Research, and Institute for Clinical and Translational Research, Johns Hopkins Medical Institutions, Baltimore, MD, USA
| | - Jeffrey B. Stambough
- Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Benjamin M. Stronach
- Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Simon C. Mears
- Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| |
Collapse
|
5
|
Cha Y, Chung JY, Jung CH, Kim JW, Lee J, Yoo JI, Kim JT, Jeon Y. Pre-sliding of femoral neck system improves fixation stability in pauwels type III femoral neck fracture: a finite element analysis. BMC Musculoskelet Disord 2023; 24:506. [PMID: 37344858 PMCID: PMC10286416 DOI: 10.1186/s12891-023-06631-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 06/13/2023] [Indexed: 06/23/2023] Open
Abstract
BACKGROUND Femoral neck fractures are a common injury in older adults and their management presents a significant challenge for orthopedic surgeons. The Femoral Neck System (FNS) was recently introduced for the fixation of femur neck fractures. Although neck shortening was reduced with the FNS, the complication rates were not reduced. Thus, improvements to enhance fixation stability should be made for the FNS. We hypothesized that (1) the pre-sliding technique and (2) the use of longer anti-rotation screw would increase fracture stability. This study aimed to determine the change in fracture stability using the pre-sliding technique and long anti-rotation screw in the FNS for fixation of Pauwels type III femoral neck fractures. METHODS Finite element models of Pauwels type III femoral neck fracture fixed with pre-sliding FNS and 5-mm longer anti-rotation screw were established. The models were subjected to normal walking load. The material properties of the elements belonging to the bone were mapped by assigning the formulation with the computed tomography Hounsfield unit. RESULTS Pauwels type III femoral neck fractures fixed with pre-slided FNS showed better fracture stability, decreasing fracture gap and sliding by 14% and 12%, respectively, under normal walking load. No element of cortical bone in any of the models had an absolute value of principal strain that exceeded 1%. The peak von Mises stress (VMS) of the implants ranged from 260 to 289 MPa, and the highest peak VMS value was 50% lower than the yield strength of the titanium alloy (800 MPa). The longer anti-rotation screw did not affect fracture stability. CONCLUSIONS The pre-sliding technique using the FNS showed higher fracture stability than the standard fixation technique for a Pauwels type III femoral neck fracture. The longer anti-rotation screw did not contribute significantly to fixation stability. As this finite element analysis considered the inhomogeneous mechanical property of the bone, it offered equivalent mechanical conditions to investigate the components of interest.
Collapse
Grants
- HI22C0494 the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea
- HI22C0494 the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea
- HI22C0494 the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea
- HI20C2140 the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea
- 2022R1G1A1003299 the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT)
- the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea
Collapse
Affiliation(s)
- Yonghan Cha
- Department of Orthopaedic Surgery, Eulji university hospital, Daejeon, Korea
| | - Jun Young Chung
- Department of Orthopedic Surgery, Ajou University School of Medicine, Ajou Medical Center, 164, World cup-ro, Yeongtong-gu, 16499, Suwon, Suwon-si, Gyeonggi-do, Korea
| | - Chang-Ho Jung
- Department of Mechanical Engineering, Ajou University, Suwon, Korea
| | - Jin-Woo Kim
- Department of Orthopaedic Surgery, Nowon Eulji Medical Center, Eulji University, Seoul, Korea
| | - Jeyoon Lee
- Department of Orthopedic Surgery, Ajou University School of Medicine, Ajou Medical Center, 164, World cup-ro, Yeongtong-gu, 16499, Suwon, Suwon-si, Gyeonggi-do, Korea
| | - Jun-Il Yoo
- Department of Orthopedic Surgery, Inha University Hospital, Incheon, Korea
| | - Jung-Taek Kim
- Department of Orthopedic Surgery, Ajou University School of Medicine, Ajou Medical Center, 164, World cup-ro, Yeongtong-gu, 16499, Suwon, Suwon-si, Gyeonggi-do, Korea.
| | - Yongho Jeon
- Department of Mechanical Engineering, Ajou University, Suwon, Korea
| |
Collapse
|
6
|
Effect of Combining Operating Room Nursing Based on Clinical Quantitative Assessment with WeChat Health Education on Postoperative Complications and Quality of Life of Femoral Fracture Patients Undergoing Internal Fixation. JOURNAL OF HEALTHCARE ENGINEERING 2022; 2022:2452820. [PMID: 35186223 PMCID: PMC8849898 DOI: 10.1155/2022/2452820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 01/17/2022] [Accepted: 01/19/2022] [Indexed: 11/17/2022]
Abstract
Objective To explore the effect of combining operating room nursing based on clinical quantitative assessment with WeChat health education on postoperative complications and quality of life (QOL) of femoral fracture patients undergoing internal fixation. Methods Ninety femoral fracture patients treated in our hospital (July 2018 to July 2021) were chosen as the research objects and split into the control group (routine intervention) and the study group (combination of operating room nursing based on clinical quantitative assessment and WeChat health education) according to the nursing intervention modes, with 45 cases each. After nursing, the postoperative complications and QOL of patients were compared between the two groups. Results No statistical between-group differences in general data were observed (P > 0.05); the hospital stay, weight-bearing time, and fracture healing time were obviously shorter in the study group than in the control group (P < 0.05); 1 d after surgery, the VAS pain status was not significantly different between the two groups (P > 0.05), and 2 d and 3 d after surgery, the VAS scores were significantly lower in the study group than in the control group (P < 0.05); 1 d after surgery, the Harris scores of patients in the two groups were close and did not present statistical difference (P > 0.05), and 8 weeks after surgery, the Harris score was significantly higher in the study group than in the control group (P < 0.05); the scores on self-care agency such as self-concept, self-care skills, sense of self-care responsibility, and health knowledge level were significantly higher in the study group than in the control group (P < 0.05); compared with the control group, the probability of occurring incision infection, lung infection, pressure sore, swelling and pain, and other complications was significantly lower in the study group (P < 0.05). Conclusion Implementing operating room nursing based on clinical quantitative assessment combined with WeChat health education to femoral fracture patients undergoing internal fixation can effectively improve their postoperative clinical indicators, reduce their postoperative pain sensation and complication incidence, and effectively promote the joint motion range, which is conducive to enhancing their self-care agency and QOL.
Collapse
|
7
|
Outcomes of basicervical femoral neck fracture treated with percutaneous compression plate (PCCP). Injury 2021; 52 Suppl 4:S42-S46. [PMID: 34030863 DOI: 10.1016/j.injury.2021.03.062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 02/28/2021] [Accepted: 03/02/2021] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Basicervical femoral neck fracture is associated with high rates of failure due instability patterns, mainly collapse and rotational instability. The purpose of this study was to evaluate the clinical-radiological results of a group of patients with a bascervical proximal femoral fractures treated with Percutaneous Compression Plate (PCCP). MATERIAL AND METHODS Among 5817 patients with a hip fracture who were admitted in our hospital from January 2005 to December 2017, 234 factures (4%) were diagnosed of basicervical femoral fracture. 30 of them were treated with a PCCP, 22 women and 8 men, mean age was 81.2 years (63-94). Demographic and perioperative variables were collected. The patients were followed up at 1, 3 and 6 months clinically and radiologically. RESULTS There were no intra-operative complications and no conversions to open surgery. There was no early implant failure. No surgical wound infection was diagnosed. Crude mortality was 13% the first year and 87% were able to walk at the 6 months. The last follow-up x-rays revealed 97% fracture healing and the collapse at fracture site occurred in 4 hips. No instances of cut-out were observed. In one case, a fatigue failure of the lag screws of a PCCP plate was observed at 3 months from osteosynthesis. CONCLUSION PCCP is an appropriated implant for basicervical femoral neck fractures.
Collapse
|
8
|
Femoral Neck Shortening After Hip Fracture Fixation Is Associated With Inferior Hip Function: Results From the FAITH Trial. J Orthop Trauma 2019; 33:487-496. [PMID: 31464855 DOI: 10.1097/bot.0000000000001551] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To describe the distribution of femoral neck shortening after internal fixation and to determine whether shortening is associated with inferior hip function at 24 months after a hip fracture in patients 50 years of age or older. DESIGN Retrospective cohort study. SETTING A secondary analysis of data from 81 clinical centers included in the Fixation using Alternative Implants for the Treatment of Hip Fractures (FAITH) trial. PARTICIPANTS Three hundred fifty patients, 50 years of age or older, who had an isolated femoral neck fracture and underwent timely operative fixation of the fracture. INTERVENTION Femoral neck shortening was measured as a categorical variable and classified into one of the following groups, as determined by the Central Adjudication Committee: no shortening, mild shortening (≤5 mm), moderate shortening (6-10 mm), or severe shortening (>10 mm). MAIN OUTCOME MEASUREMENT The primary outcome for the current analysis was hip function, as measured by the Western Ontario & McMaster Universities Osteoarthritis Index questionnaire, at 24 months after injury. RESULTS Two-thirds of patients had no or mild shortening (≤5 mm), whereas one-third of patients had moderate or severe shortening (>5 mm). After adjusting for surgical treatment, a greater amount of femoral neck shortening was found to be associated with poorer hip function (P < 0.01). CONCLUSIONS We found that increasing femoral neck shortening was associated with inferior hip function. Although internal fixation often results in successful union, patients who heal in a shortened position report poorer functional outcomes. LEVEL OF EVIDENCE Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
9
|
Ramallo DA, Kropf LL, Zaluski AD, Cavalcanti ADS, Duarte MEL, Guimarães JAM. Factors Influencing the Outcome of Osteosynthesis in the Fracture of the Femoral Neck in Young Adult Patients. Rev Bras Ortop 2019; 54:408-415. [PMID: 31435107 PMCID: PMC6701963 DOI: 10.1016/j.rbo.2017.12.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Accepted: 12/22/2017] [Indexed: 11/21/2022] Open
Abstract
Objectives
To evaluate the factors that influence the outcome of osteosynthesis after closed reduction of the fracture of the femoral neck in young adult patients.
Methods
A retrospective study was conducted, reviewing the data of patients operated in a large orthopedic hospital from 2003 to 2011; a total of 81 patients met the inclusion criteria. The time interval between the fracture and the surgery, the initial fracture deviation, the quality of the reduction, and the placement of the implant were evaluated.
Results
The present study observed a strong relationship between the quality of the reduction and therapeutic success. The degree of the initial deviation and the time elapsed between the initial trauma and the osteosynthesis did not influence the surgical outcome regarding bone consolidation. The correct positioning of the implants was associated with a satisfactory evolution in the postoperative period.
Conclusion
The quality of the reduction and the positioning of the implants are factors that influence the results of osteosynthesis in fractures of the femoral neck in young adult patients.
Collapse
Affiliation(s)
- Daniel Alves Ramallo
- Centro de Trauma, Instituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, RJ, Brasil
| | - Leandro Lemgruber Kropf
- Centro de Trauma, Instituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, RJ, Brasil
| | | | | | | | - João Antonio Matheus Guimarães
- Centro de Trauma, Instituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, RJ, Brasil.,Centro de Pesquisa Clínica, Instituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, RJ, Brasil
| |
Collapse
|
10
|
Factors influencing femoral neck fracture healing after internal fixation with dynamic locking plate. Arch Orthop Trauma Surg 2019; 139:629-638. [PMID: 30617416 DOI: 10.1007/s00402-018-03103-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Indexed: 10/27/2022]
Abstract
INTRODUCTION The purpose of this study was to determine factors that affect the early failure of femoral neck fracture healing after internal fixation with a dynamic locking plate implant. PATIENTS AND METHODS Retrospective analysis of all cases of femoral neck fracture (FNF) primarily treated with dynamic locking plate implant from 04/2014 to 04/2017 with a minimum of 6 month follow-up. For the purpose of the study age, sex and time from admission to surgery were retrieved from the hospital medical database. Patient's pre- and postoperative hip radiographs were reviewed by the authors. Radiographically detected fracture healing failure (non-union and screw cut-out) was recorded. RESULTS For the period of the study, there were 77 consecutive FNF (76 patients) treated with the dynamic locking plate implant. Eight (10%) patients were lost to follow-up, 13 (17%) patients died within 6 months after surgery. Healing failure was identified in 23 (41%) of remaining 56 cases. Three of four (75% failure rate) failures were observed in cases with fair-quality reduction and two of two (100% failure rate) failures were noticed in the case of none telescoping screw located within subchondral bone. Multiple logistic regression showed an increased risk of fracture failure in cases with at least one completely collapsed telescoping screw (OR = 73.2; 95% CI 9.4-568.5, p < 0.01), while telescoping screws' location around centre of the femoral head reduces the risk of failure (OR = 14.7; 95% CI 1.6-135.1, p = 0.02). CONCLUSION In our group of patients, fracture healing failure of the FNF treated with dynamic locking plate reached 41%. This high failure rate was associated with poor fracture reduction, not subchondrally and centrally placed telescoping screws and in the case of complete collapse on at least one of the telescoping screws.
Collapse
|
11
|
Xiong WF, Zhang YQ, Chang SM, Hu SJ, Du SC. Lesser Trochanteric Fragments in Unstable Pertrochanteric Hip Fractures: A Morphological Study Using Three-Dimensional Computed Tomography (3-D CT) Reconstruction. Med Sci Monit 2019; 25:2049-2057. [PMID: 30889172 PMCID: PMC6436204 DOI: 10.12659/msm.913593] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Background The lesser trochanter (LT) posterior cortical extension (LTPE) fragment is important for joint stability during reconstruction in unstable pertrochanteric hip fractures. This study aimed to investigate the morphological characteristics of the LT fragments using three-dimensional computed tomography (3-D CT) reconstruction and to compare clinical outcomes in different subgroups of 31A2 fractures. Material/Methods A retrospective study included CT images of 58 cases of 31A2 type unstable pertrochanteric fractures, using the Arbeitsgemeinschaft für Osteosynthesefragen and Orthopedic Trauma Association (AO/OTA) classification. After 3-D CT reconstruction, all the displaced fragments were reduced and the morphologic parameters of the LT fragments were measured. Results At the mid-level of the LT, the mean cortical extension of the LT fragment was 33.5 mm in the posterior wall (83%), 19.0 mm in the medial wall (53%). The mean distal cortical extension from the lower edge of the LT was 13.0 mm. The LT fragment occupied 38% of the whole cortical circumference. Comparison of the subgroups showed that the LT fragment of A2.3 had a larger cortical extension in the posterior, medial, and distal cortex. The mean fracture collapse was 4.7 mm in A2.2 fractures and 5.4 mm in A2.3 fractures (p=0.311). Despite the increased size of the LT fragment in subtype A2.3 fracture compared with subtype A2.2 fracture, this did not influence the clinical outcome. Conclusions The 3-D morphology of the LT fragment from CT imaging provided a better understanding of the characteristics of subgroups of unstable pertrochanteric fractures, which may improve and guide implant choice.
Collapse
Affiliation(s)
- Wen-Feng Xiong
- Department of Orthopedic Surgery, Yangpu Hospital, Tongji University School of Medicine, Shanghai, China (mainland)
| | - Ying-Qi Zhang
- Department of Orthopedic Surgery, Tongji Hospital, Tongji University School of Medicine, Shanghai, China (mainland)
| | - Shi-Min Chang
- Department of Orthopedic Surgery, Yangpu Hospital, Tongji University School of Medicine, Shanghai, China (mainland)
| | - Sun-Jun Hu
- Department of Orthopedic Surgery, Yangpu Hospital, Tongji University School of Medicine, Shanghai, China (mainland)
| | - Shou-Chao Du
- Department of Orthopedic Surgery, Yangpu Hospital, Tongji University School of Medicine, Shanghai, China (mainland)
| |
Collapse
|
12
|
Garden 1 and 2 Femoral Neck Fractures Collapse More Than Expected After Closed Reduction and Percutaneous Pinning. J Orthop Trauma 2019; 33:116-119. [PMID: 30779723 DOI: 10.1097/bot.0000000000001360] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVES To report on the final displacement after in situ percutaneous pinning for Garden type 1 and 2 fractures in height, femoral neck fracture collapse, and loss of offset. DESIGN Retrospectively reviewed case series. SETTING Three Academic Medical Centers. Boston University Medical Center (Level 1 Trauma Center), Lahey Hospital and Medical Center (Level 2 Trauma Center), and Geisinger Medical Center (level 2 Trauma Center). PATIENTS/PARTICIPANTS One hundred thirty skeletally mature patients with 130 fractures (78 garden 1 and 52 garden 2) who were treated between January 2000 and January 2014 at participating hospitals with percutaneous pinning with a cannulated screw system to successful union after sustaining an intracapsular femoral neck fracture without complete displacement. INTERVENTION In situ percutaneous pinning with 3 cannulated, partially threaded screws in an inverted triangle orientation. MAIN OUTCOME MEASUREMENTS Femoral neck fracture collapse (mm), femoral height shortening (mm), and femoral offset shortening (mm). RESULTS A total of 130 patients (81F, 49M), average age 72 years, sustained 78 Garden 1 and 52 Garden 2 femoral neck fractures. Maximal collapse occurred in the plane of the femoral neck. Thirty-three of 78 (42%) Garden 1 fractures and 33/52 (63%) Garden 2 fractures demonstrated >10 mm fracture collapse. The range of displacements was 0-39 mm as measured along the plane of the femoral neck. CONCLUSIONS Garden 1 fractures collapse less frequently than Garden 2 fractures, but both have high rates of fracture collapse when treated to union with in situ percutaneous pin fixation. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
13
|
Femoral neck fractures after internal fixation of trochanteric fractures with implants in situ in adults: A systematic review. Injury 2018; 49:2121-2131. [PMID: 30526921 DOI: 10.1016/j.injury.2018.11.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Femoral neck fractures (FNF) after internal fixation of trochanteric fractures (AIFTF) with the implant in situ (WIIS) are uncommon. Publications of FNFAIFTFWIIS are rare. The purpose of this systematic review of the literature is to report on the frequency, risk factors, mechanisms, clinical presentation, diagnostic and therapeutic modalities, outcomes and the eventual prevention of this complication. MATERIALS AND METHODS A comprehensive review of the literature was undertaken using the PRISMA guidelines with no language restriction. Case reports of FNFAIFTFWIIS and series of trochanteric fractures (TF) with this complication in adults published between inception of journals to May 2018 were eligible for inclusion. Cases with fractures in pathological bone, undergoing treatment with hip replacement, or after partial or total implant removal were excluded. Relevant information was divided in two parts. Part I included the analysis of cases of FNFAIFTFWIIS, with the objective of establishing the eventual risk factors, mechanisms, diagnostic, treatment modalities, and outcomes. Part II analyzed series of TFs with implants in situ which included cases of FNFs for assessing the incidence of FNFs in this condition. RESULTS Overall 77 publications with 104 cases of FNFAIFTFWIIS met the inclusion criteria. The median incidence of this complication was 0,43%. The mean age was 80 years (range, 42-96).The prevalent factors for FNFAIFTFWIIS were osteoporosis, and the presence of the implant in the femoral neck and head. A short nail or screw with the tip far from the subchondral bone was of influence as a stress riser factor, but not prevalent because in two thirds of the cases the FNF occurred when the implant was introduced up to the subchondral bone. Other risk factors analysed included varus reduction or nonunion of the TF, and the breakage of the hip screw, which modify the forces exerted over the femoral neck, and may contribute to the FNF. The FNFs were spontaneous, i.e. not related to trauma or fall, in more than two thirds of the cases. CONCLUSION The etiology of FNFAIFTFWII should be considered multifactorial. The frequency seems low. Although a subchondral positioning of the hip screw might diminish the incidence of FNFS, a correct surgical technique does not preclude a FNFAIFTFWIIS, and in fact the incidence of this complication was higher in these correctly treated patients. FNFAIFTFWIIS is a fragility fracture and adequate management of systemic osteoporosis should be targeted as a main factor of prevention.
Collapse
|
14
|
Hou Y, Yao Q, Zhang G, Ding L. [Comparative study of proximal femoral shortening after the third generation of Gamma nail versus proximal femoral nail anti-rotation in treatment of intertrochanteric fracture]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2018; 32:338-345. [PMID: 29806285 DOI: 10.7507/1002-1892.201710065] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Objective To explore the difference of the proximal femoral shortening (PFS) between the third generation of Gamma nail (TGN) and the proximal femoral nail anti-rotation (PFNA) in treating intertrochanteric fracture of femur. Methods The clinical data of 158 patients with intertrochanteric fracture of femur who were treated with TGN internal fixation or PFNA internal fixation between January 2014 and December 2015 were retrospectively analysed. The patients were divided into TGN group (69 cases) and PFNA group (89 cases) according to surgical operation. There was no significant difference in gender, age, bone mineral density, causes of injury, AO/Association for the Study of Internal Fixation (AO/ASIF) classification, accompanied disease, and the time from injury to operation between 2 groups ( P>0.05). The result of fracture reduction was divided into 3 types: positive medial cortex support, neutral position cortex support, and negative medial cortex support according to the method of Chang et al. At 18 months postoperatively, bilateral hip anteroposterior X-ray films were taken to measure horizontal PFS values (marked as X), vertical PFS values (marked as Y), and calculate the total PFS values (marked as Z). The PFS values were divided into 4 grades according to the criteria (≤1.0 mm, 1.0-4.9 mm, 5.0-9.9 mm, and ≥10.0 mm), and the constituent ratio was calculated and compared between 2 groups. The X, Y, and Z values and the collodiaphyseal angles of 2 groups at 18 months postoperatively were compared. The X, Y, and Z values of 2 groups of patients with failed fixation and normal healing within 18 months after operation were recorded and compared. The X, Y, and Z values of 2 groups of the patients with different cortex support types were also compared. Results There were 34 cases of positive medial cortex support, 30 cases of neutral position cortex support, and 5 cases of negative medial cortex support in TGN group, and there were 45, 33, and 11 cases in PFNA group respectively, showing no significant difference between 2 groups ( Z=-1.06, P=0.29). All patients were followed up 18 months after operation. At 18 months after operation, the constituent ratios of PFS values (X, Y, Z) had significant differences between 2 groups ( P<0.05). The patients of shortening of 1.0-4.9 mm and 5.0-9.9 mm were obviously more in TGN group than in PFNA group; the patients of shortening of ≥10.0 mm were obviously more in PFNA group than in TGN group. There were significant differences in X, Y, and Z values between 2 groups ( P<0.05), but no significant difference of the collodiaphysial angle was found between 2 groups ( t=0.47, P=0.64). Six cases of internal fixation failed in TGN group and PFNA group respectively within 3 months after operation, and there was no significant difference of X, Y, and Z values between failed fixation and normal healing patients within 2 groups ( P>0.05). When the reposition effect was the positive medial cortex support, the X, Y, and Z values were significantly lower in TGN group than in PFNA group ( P<0.05); but no significant difference was found between 2 groups when the reposition effect was the neutral position cortex support or negative medial cortex support ( P>0.05). At 18 months after operation, the X, Y, and Z values of the negative medial cortex support patients were significantly higher than those of the positive medial cortex support or the neutral position cortex support patients within 2 groups ( P<0.05). Conclusion PFS is a common complication of the intertrochanteric fracture of the femur after internal fixation. During operation, the selection of internal fixation should be based on the results of intraoperative reduction. TGN should be applied to reduce PFS if positive medial cortex support happened.
Collapse
Affiliation(s)
- Yu Hou
- Department of Spinal Surgery, Beijing Shijitan Hospital, Capital Medical University, Beijing, 100038,
| | - Qi Yao
- Department of Spinal Surgery, Beijing Shijitan Hospital, Capital Medical University, Beijing, 100038, P.R.China
| | - Gen'ai Zhang
- Department of Spinal Surgery, Beijing Shijitan Hospital, Capital Medical University, Beijing, 100038, P.R.China
| | - Lixiang Ding
- Department of Spinal Surgery, Beijing Shijitan Hospital, Capital Medical University, Beijing, 100038, P.R.China
| |
Collapse
|
15
|
Lee YK, Yoon BH, Hwang JS, Cha YH, Kim KC, Koo KH. Risk factors of fixation failure in basicervical femoral neck fracture: Which device is optimal for fixation? Injury 2018; 49:691-696. [PMID: 29433801 DOI: 10.1016/j.injury.2018.02.009] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Revised: 01/31/2018] [Accepted: 02/07/2018] [Indexed: 02/02/2023]
Abstract
BACKGROUND Basicervical femur neck fracture (FNF) is a rare type of fracture, and is associated with increased risk of fixation failure due to its inherent instability. The purpose of this study was (1) to investigate the incidence of fixation failure and (2) to determine risk factors for fixation failure in basicervical FNF after internal fixation. METHODS To identify basicervical FNF with a minimum of 12 months follow-up, we retrospectively reviewed records of 3217 patients who underwent hip fracture surgery from May 2003 to March 2016. Among the identified 77 patients with basicervical FNF, 69 patients were followed up for at least 12 months. We evaluated the rate of collapse of fracture site and reoperation due to fixation failure. We performed a multivariable analysis to determine risk factors associated with fracture site collapse and fixation failure. RESULTS Among the 69 patients with basicervical FNF, 17 (24.6%) showed collapse of fracture site, and 6 (8.6%) underwent conversion to arthroplasty because of fixation failure. In the multivariable analysis, use of extramedullary plating with a sliding hip screw was an independent significant risk factor for both collapse of fracture site (odds ratio 6.84; 95% confidence interval 1.91-24.5, p = 0.003) and fixation failure (odds ratio 12.2; 95% confidence interval 1.08-137.7, p = 0.042). CONCLUSIONS Basicervical FNF treated with extramedullary plate with a sliding hip screw is more likely to fail than that treated with intramedullary nail with a helical blade. Our results suggested that intramedullary nail with a helical blade is more recommended for basicervical FNF compared with extramedullary plate with a sliding hip screw. LEVEL OF EVIDENCE III, Retrospective cohort study.
Collapse
Affiliation(s)
- Young-Kyun Lee
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea.
| | - Byung-Ho Yoon
- Department of Orthopaedic Surgery, Inje University College of Medicine, Seoul Paik Hospital, Seoul, South Korea.
| | - Ji Sup Hwang
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea.
| | - Yong-Han Cha
- Department of Orthopedic Surgery, Eulji University Hospital, 95, Dunsanseo-ro, Seo-gu 35233, South Korea.
| | - Ki-Choul Kim
- Department of Orthopaedic Surgery, Dankook University College of Medicine, Dongnam-gu, Cheonan-si, Chungcheongnam-do, South Korea.
| | - Kyung-Hoi Koo
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea.
| |
Collapse
|
16
|
Femoral neck shortening in adult patients under the age of 55 years is associated with worse functional outcomes: Analysis of the prospective multi-center study of hip fracture outcomes in China (SHOC). Injury 2017; 48:1837-1842. [PMID: 28651782 DOI: 10.1016/j.injury.2017.06.013] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2017] [Revised: 06/07/2017] [Accepted: 06/19/2017] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Young femoral neck fracture patients require surgical fixation to preserve the native hip joint and accommodate increased functional demands. Recent reports have identified a high incidence of fracture shortening and this may have negative functional consequences. We sought to determine if fracture shortening is associated with poor functional outcome in young femoral neck fracture patients. PATIENTS AND METHODS One hundred and forty-two patients with femoral neck fractures age 18-55 were recruited in this prospective cohort study across three Level 1 trauma hospitals in Mainland China. Patient-reported and objective functional outcomes were measured with the Harris Hip Score (HHS), Timed Up and Go (TUG), and SF-36 Physical Component Summary (SF-36 PCS) at 12 months. Radiographic fracture shortening was measured along the long axis of the femoral neck and corrected for magnification. Severe shortening was defined as ≥10mm. The primary analysis measured associations between severe radiographic shortening and HHS at one-year post-fixation. RESULTS One hundred and two patients had complete radiographic and functional outcomes available for analysis at one year. The mean age of participants was 43.7±10.8years and 53% were male. Fifty-five percent of fractures were displaced and 37% were vertically orientated (Pauwels Type 3). The mean functional outcome scores were: HHS 90.0±10.8, TUG 12.0±5.1s, and PCS 48.5±8.6. Severe shortening occurred in 13% of patients and was associated with worse functional outcome scores: HHS mean difference 9.9 (p=0.025), TUG mean difference 3.2s (p=0.082), and PCS mean difference 5.4 (p=0.055). CONCLUSIONS Severe shortening is associated with clinically important decreases in functional outcome as measured by HHS following fixation of young femoral neck fractures, occurring in 13% of patients in this population. The principle of fracture site compression utilized by modern constructs may promote healing; however, excessive shortening is associated with worse patient-reported outcomes and objective functional measures.
Collapse
|