1
|
Wahyuni WT, Putra BR, Rahman HA, Ivandini TA, Irkham, Khalil M, Rahmawati I. Effect of Aspect Ratio of a Gold-Nanorod-Modified Screen-Printed Carbon Electrode for Carbaryl Detection in Three Different Samples of Vegetables. ACS OMEGA 2024; 9:1497-1515. [PMID: 38239286 PMCID: PMC10796111 DOI: 10.1021/acsomega.3c07831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 11/24/2023] [Accepted: 12/01/2023] [Indexed: 01/22/2024]
Abstract
In this study, three different sizes of gold nanorods (AuNRs) were synthesized using the seed-growth method by adding various volumes of AgNO3 as 400, 600, and 800 μL into the growth solution of gold nanoparticles. Three different sizes of AuNRs were then characterized using UV-vis spectroscopy, high-resolution transmission electron microscopy (HRTEM), selected area electron diffraction (SAED) patterns, and atomic force microscopy (AFM) to investigate the surface morphology, topography, and aspect ratios of each synthesized AuNR. The aspect ratios from the histogram of size distributions of three AuNRs as 2.21, 2.53, and 2.85 can be calculated corresponding to the addition of AgNO3 volumes of 400, 600, and 800 μL. Moreover, each AuNR in three different aspect ratios was drop-cast onto the surface of a commercial screen-printed carbon electrode (SPCE) to obtain three different SPCE-modified AuNRs (SPCE-A400, SPCE-A600, and SPCE-A800, respectively). All SPCE-modified AuNRs were then evaluated for their electrochemical behavior using cyclic voltammetry and electrochemical impedance spectroscopy (EIS) techniques and the highest electrochemical performance was shown as the order of magnitude of SPCE-A400 > SPCE-A600/SPCE-A800. The reason for the highest electrocatalytic activity of SPCE-A400 might be due to the smallest particle size and uniform distribution of AuNRs ∼ 2.2, which enhanced the charge transfer, thus providing the highest electroactive surface area (0.6685 cm2) compared to other electrodes. These results also confirm that the sensing mechanism for all SPCE-modified AuNRs is controlled by diffusion phenomena. In addition, the optimum pH was obtained as 4 for carbaryl detection for all SPCE-modified AuNRs with the highest current shown by SPCE-A400. Furthermore, SPCE-A400 has the highest fundamental parameters (surface coverage, catalytic rate constant, electron transfer rate constant, and adsorption capacity) for carbaryl detection, which were investigated using cyclic voltammetry and chronoamperometric techniques. The electroanalytical performances of all SPCE-modified AuNRs for carbaryl detection were also investigated with SPCE-A400 displaying the best performance among other electrodes in terms of its linearity (0.2-100 μM), limit of detection (LOD) ∼ 0.07 μM, and limit of quantification (LOQ) ∼ 0.2 μM. All SPCE-modified AuNRs were also subsequently evaluated for their stability, reproducibility, and selectivity in the presence of interfering species such as NaNO2, NH4NO3, Zn(CH3CO2)2, FeSO4, diazinon, and glucose and show reliable results as depicted from %RSD values less than 3%. At last, all SPCE-modified AuNRs have been employed for carbaryl detection using a standard addition technique in three different samples of vegetables (cabbage, cucumber, and Chinese cabbage) with its results (%recovery ≈ 100%) within the acceptable analytical range. In conclusion, this work demonstrates the great potential of a disposable device based on an AuNR-modified SPCE for rapid detection and high sensitivity in monitoring the concentration of carbaryl as a residual pesticide in vegetable samples.
Collapse
Affiliation(s)
- Wulan Tri Wahyuni
- Analytical
Chemistry Division, Department of Chemistry, Faculty of Mathematics
and Natural Sciences, Kampus IPB Dramaga, Bogor 16680, Indonesia
- Tropical
Biopharmaca Research Center, Institute of Research and Community Empowerment, IPB University, Bogor 16680, Indonesia
| | - Budi Riza Putra
- Research
Center for Metallurgy, National Research
and Innovation Agency (BRIN), PUSPIPTEK Gd. 470, South
Tangerang, Banten 15315, Indonesia
| | - Hemas Arif Rahman
- Analytical
Chemistry Division, Department of Chemistry, Faculty of Mathematics
and Natural Sciences, Kampus IPB Dramaga, Bogor 16680, Indonesia
| | - Tribidasari A. Ivandini
- Department
of Chemistry, Faculty of Mathematics and Natural Sciences, University of Indonesia, Depok 16424, Indonesia
| | - Irkham
- Department
of Chemistry, Faculty of Mathematics and Natural Sciences, University of Padjajaran, Bandung 45363, Indonesia
| | - Munawar Khalil
- Department
of Chemistry, Faculty of Mathematics and Natural Sciences, University of Indonesia, Depok 16424, Indonesia
| | - Isnaini Rahmawati
- Department
of Chemistry, Faculty of Mathematics and Natural Sciences, University of Indonesia, Depok 16424, Indonesia
| |
Collapse
|
2
|
Electrochemical sensor based on epoxy-functionalized BEA nanozeolite and graphene oxide modified glassy carbon electrode for bisphenol E determination. J APPL ELECTROCHEM 2023. [DOI: 10.1007/s10800-023-01875-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2023]
Abstract
AbstractAn epoxy-functionalized beta type nanozeolite (BEA)/graphene oxide nanocomposite modified glassy carbon electrode (GCE/BEA/APTMS/GA/GO/NF) has been created for the differential pulse voltammetric determination of bisphenol E (BPE). The modified electrode presented an enhanced current response in comparison with bare GCE. A linear dependence of anodic peak current (Ip) and scan rate (ν) was observed, which showed that the electrochemical process was adsorption-controlled. Differential pulse voltammetry (DPV) was employed and optimized for the sensitive determination of BPE. Under the optimized conditions, the anodic peak current was linearly proportional to BPE concentration in the range between 0.07 and 4.81 µM, with a correlation coefficient of 0.995 and limit of detection 0.056 μM (S/N = 3). The electrode showed good repeatability and storage stability, and a low response to interfering compounds. Comparison was made to the determination of bisphenol A. To confirm the electrode analytical performance, recovery tests were performed, and deviations lower than 10% were found. The BEA zeolite-GO nanocomposite proved to be a promising sensing platform for bisphenol determination.
Graphical abstract
Collapse
|
3
|
Almeida EMF, De Souza D. Current electroanalytical approaches in the carbamates and dithiocarbamates determination. Food Chem 2023; 417:135900. [PMID: 36944296 DOI: 10.1016/j.foodchem.2023.135900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 02/16/2023] [Accepted: 03/06/2023] [Indexed: 03/17/2023]
Abstract
Pesticides are a suitable tool for controlling plagues and disease vectors. However, their inappropriate use allows for contamination of the environment, soil, water, and foods. Carbamates and dithiocarbamates pesticides present accumulative effects in the human body resulting in hormonal, neurological and reproductive disorders, and some are still suspected or proven to give carcinogenic or mutagenic effects. This review provides a current electroanalytical approach in the carbamates and dithiocarbamates determination, showing the use of voltammetric techniques such as amperometry, cyclic and linear scan, differential pulse, and square wave voltammetry, indicating their advantages, disadvantages, and perspectives in electroanalytical detection of carbamates and dithiocarbamates in natural water and foods. Also are reported the different materials used in the preparation of working electrodes since their choice has an important impact on the success of the analytical applications, resulting in suitable sensitivity, selectivity, stability, and robustness.
Collapse
Affiliation(s)
- Elis Marina Fonseca Almeida
- Laboratory of Electroanalytical Applied to Biotechnology and Food Engineering (LEABE), Chemistry Institute, Uberlândia Federal University, Major Jerônimo Street, 566, Patos de Minas, MG 38700-002, Brazil
| | - Djenaine De Souza
- Laboratory of Electroanalytical Applied to Biotechnology and Food Engineering (LEABE), Chemistry Institute, Uberlândia Federal University, Major Jerônimo Street, 566, Patos de Minas, MG 38700-002, Brazil.
| |
Collapse
|
4
|
Le Nhat Trang N, Thi Nguyet Nga D, Tufa LT, Tran VT, Hung TT, Ngoc Phan V, Pham TN, Hoang VT, Le AT. Unveiling the effect of crystallinity and particle size of biogenic Ag/ZnO nanocomposites on the electrochemical sensing performance of carbaryl detection in agricultural products. RSC Adv 2023; 13:8753-8764. [PMID: 36936823 PMCID: PMC10016934 DOI: 10.1039/d3ra00399j] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 03/10/2023] [Indexed: 03/17/2023] Open
Abstract
In this study, bio-Ag/ZnO NCs were synthesized via a microwave-assisted biogenic electrochemical method using mangosteen (Garcinia mangostana) peel extract as a biogenic reducing agent for the reduction of Zn2+ and Ag+ ions to form hybrid nanoparticles. The as-synthesized NC samples at three different microwave irradiation temperatures (Z 70, Z 80, Z 90) exhibited a remarkable difference in size and crystallinity that directly impacted their electrocatalytic behaviors as well as electrochemical sensing performance. The obtained results indicate that the Z 90 sample showed the highest electrochemical performance among the investigated samples, which is attributed to the improved particle size distribution and crystal microstructure that enhanced charge transfer and the electroactive surface area. Under the optimal conditions for carbaryl pesticide detection, the proposed nanosensor exhibited a high electrochemical sensitivity of up to 0.303 μA μM-1 cm-2 with a detection limit of LOD ∼0.27 μM for carbaryl pesticide detection in a linear range of 0.25-100 μM. Overall, the present work suggests that bio-Ag/ZnO NCs are a potential candidate for the development of a high-performance electrochemical-based non-enzymatic nanosensor with rapid monitoring, cost-effectiveness, and eco-friendly to detect carbaryl pesticide residues in agricultural products.
Collapse
Affiliation(s)
- Nguyen Le Nhat Trang
- Phenikaa University Nano Institute (PHENA), Phenikaa University Hanoi 12116 Vietnam
| | - Dao Thi Nguyet Nga
- Phenikaa University Nano Institute (PHENA), Phenikaa University Hanoi 12116 Vietnam
| | - Lemma Teshome Tufa
- Department of Chemical Engineering and Applied Chemistry, Chungnam National University Daejeon 34134 Republic of Korea
| | - Van Tan Tran
- Faculty of Biotechnology, Chemical and Environmental Engineering (BCEE), Phenikaa University Hanoi 12116 Viet Nam
| | - Thuan-Tran Hung
- Center for Advanced Materials and Environmental Technology, National Center for Technological Progress Hanoi 12116 Viet Nam
| | - Vu Ngoc Phan
- Phenikaa University Nano Institute (PHENA), Phenikaa University Hanoi 12116 Vietnam
- Faculty of Biotechnology, Chemical and Environmental Engineering (BCEE), Phenikaa University Hanoi 12116 Viet Nam
| | - Tuyet Nhung Pham
- Phenikaa University Nano Institute (PHENA), Phenikaa University Hanoi 12116 Vietnam
| | - Van-Tuan Hoang
- Phenikaa University Nano Institute (PHENA), Phenikaa University Hanoi 12116 Vietnam
| | - Anh-Tuan Le
- Phenikaa University Nano Institute (PHENA), Phenikaa University Hanoi 12116 Vietnam
- Faculty of Materials Science and Engineering (MSE), Phenikaa University Hanoi 12116 Vietnam
| |
Collapse
|
5
|
A kind of new type photoresponsive molecularly imprinted electrochemical sensor based on 5-[(4-(methacryloyloxy)phenyl)diazenyla]isophthalic acid for the detection of carbaryl. J Solid State Electrochem 2022. [DOI: 10.1007/s10008-022-05331-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
6
|
Rakkhun W, Jantra J, Cheubong C, Teepoo S. Colorimetric test strip cassette readout with a smartphone for on-site and rapid screening test of carbamate pesticides in vegetables. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
|
7
|
Luo Y, Wu N, Wang L, Song Y, Du Y, Ma G. Biosensor Based on Covalent Organic Framework Immobilized Acetylcholinesterase for Ratiometric Detection of Carbaryl. BIOSENSORS 2022; 12:bios12080625. [PMID: 36005021 PMCID: PMC9405660 DOI: 10.3390/bios12080625] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 08/02/2022] [Accepted: 08/08/2022] [Indexed: 01/03/2023]
Abstract
A ratiometric electrochemical biosensor based on a covalent organic framework (COFThi-TFPB) loaded with acetylcholinesterase (AChE) was developed. First, an electroactive COFThi-TFPB with a two-dimensional sheet structure, positive charge and a pair of inert redox peaks was synthesized via a dehydration condensation reaction between positively charged thionine (Thi) and 1,3,5-triformylphenylbenzene (TFPB). The immobilization of AChE on the positively charged electrode surface was beneficial for maintaining its bioactivity and achieving the best catalytic effect; therefore, the positively charged COFThi-TFPB was an appropriate support material for AChE. Furthermore, the COFThi-TFPB provided a stable internal reference signal for the constructed AChE inhibition-based electrochemical biosensor to eliminate various effects which were unrelated to the detection of carbaryl. The sensor had a linear range of 2.2–60 μM with a detection limit of 0.22 μM, and exhibited satisfactory reproducibility, stability and anti-interference ability for the detection of carbaryl. This work offers a possibility for the application of COF-based materials in the detection of low-level pesticide residues.
Collapse
Affiliation(s)
| | | | | | | | | | - Guangran Ma
- Correspondence: or ; Tel.: +86-0791-88120861
| |
Collapse
|
8
|
Albalawi I, Alatawi H, Alsefri S, Moore E. Electrochemical Synthesis of Reduced Graphene Oxide/Gold Nanoparticles in a Single Step for Carbaryl Detection in Water. SENSORS 2022; 22:s22145251. [PMID: 35890930 PMCID: PMC9317711 DOI: 10.3390/s22145251] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 06/29/2022] [Accepted: 07/11/2022] [Indexed: 12/03/2022]
Abstract
In this study, an in situ synthesis approach based on electrochemical reduction and ion exchange was employed to detect carbaryl species using a disposable, screen-printed carbon electrode fabricated with nanocomposite materials. Reduced graphene oxide (rGO) was used to create a larger electrode surface and more active sites. Gold nanoparticles (AuNPs,) were incorporated to accelerate electron transfer and enhance sensitivity. A cation exchange Nafion polymer was used to enable the adhesion of rGO and AuNPs to the electrode surface and speed up ion exchange. Cyclic voltammetry (CV), energy dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy (XPS), electrical impedance spectroscopy (EIS), atomic force microscopy (AFM) and scanning electron microscopy (SEM) were performed to study the electrochemical and physical properties of the modified sensor. In the presence of differential pulse voltammetry (DPV), an rGO/AuNP/Nafion-modified electrode was effectively used to measure the carbaryl concentration in river and tap water samples. The developed sensor exhibited superior electrochemical performance in terms of reproducibility, stability, efficiency and selectivity for carbaryl detection with a detection limit of 0.2 µM and a concentration range between 0.5µM and 250 µM. The proposed approach was compared to capillary electrophoresis with ultraviolet detection (CE-UV).
Collapse
|
9
|
Alnahdi HS, Mousa RMA, El‐Said WA. Development of Organochlorine Pesticide Electrochemical Sensor Based on Fe
3
O
4
Nanoparticles@indium Tin Oxide Electrode. ELECTROANAL 2022. [DOI: 10.1002/elan.202100659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Hanan S. Alnahdi
- University of Jeddah, College of Science, Department of Biochemistry P.O. 80327 Jeddah 21589 Saudi Arabia
| | - Rasha Mousa Ahmed Mousa
- University of Jeddah, College of Science, Department of Biochemistry P.O. 80327 Jeddah 21589 Saudi Arabia
| | - Waleed A. El‐Said
- University of Jeddah, College of Science, Department of Chemistry P.O. 80327 Jeddah 21589 Saudi Arabia
- Department of Chemistry Faculty of Science Assiut University Assiut 71516 Egypt
| |
Collapse
|
10
|
Kunpatee K, Kaewdorn K, Duangtong J, Chaiyo S, Chailapakul O, Kalcher K, Kerr M, Samphao A. A new disposable electrochemical sensor for the individual and simultaneous determination of carbamate pesticides using a nanocomposite modified screen-printed electrode. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107318] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
11
|
A Simple and Reliable Dispersive Liquid-Liquid Microextraction with Smartphone-Based Digital Images for Determination of Carbaryl Residues in Andrographis paniculata Herbal Medicines Using Simple Peroxidase Extract from Senna siamea Lam. Bark. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27103261. [PMID: 35630744 PMCID: PMC9147045 DOI: 10.3390/molecules27103261] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 04/22/2022] [Accepted: 05/17/2022] [Indexed: 02/01/2023]
Abstract
A simple and reliable dispersive liquid-liquid microextraction (DLLME) coupled with smartphone-based digital images using crude peroxidase extracts from cassia bark (Senna siamea Lam.) was proposed to determine carbaryl residues in Andrographis paniculata herbal medicines. The method was based on the reaction of 1-naphthol (hydrolysis of carbaryl) with 4-aminoantipyrine (4-AP) in the presence of hydrogen peroxide, using peroxidase enzyme simple extracts from cassia bark as biocatalysts under pH 6.0. The red product, after preconcentration by DLLME using dichloromethane as extraction solvent, was measured for blue intensity by daily life smartphone-based digital image analysis. Under optimized conditions, good linearity of the calibration graph was found at 0.10–0.50 mg·L−1 (r2 = 0.9932). Limits of detection (LOD) (3SD/slope) and quantification (LOQ) (10SD/slope) were 0.03 and 0.09 mg·L−1, respectively, with a precision of less than 5%. Accuracy of the proposed method as percentage recovery gave satisfactory results. The proposed method was successfully applied to analyze carbaryl in Andrographis paniculata herbal medicines. Results agreed well with values obtained from the HPLC-UV method at 95% confidence level. This was simple, convenient, reliable, cost-effective and traceable as an alternative method for the determination of carbaryl.
Collapse
|
12
|
Salhi O, Ez-zine T, Oularbi L, El Rhazi M. Electrochemical Sensing of Nitrite Ions Using Modified Electrode by Poly 1,8-Diaminonaphthalene/Functionalized Multi-Walled Carbon Nanotubes. Front Chem 2022; 10:870393. [PMID: 35372268 PMCID: PMC8966090 DOI: 10.3389/fchem.2022.870393] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Accepted: 03/02/2022] [Indexed: 01/17/2023] Open
Abstract
A novel electrochemical sensor based on conducting polymer and multi-walled carbon nanotubes was reported for the detection of nitrite ions (NO2−). The hybrid material poly 1,8-Diaminonaphthalene (poly 1,8-DAN)/functionalized multi-walled carbon nanotubes (f-MWCNT) was prepared by using a simple electrochemical approach which is based on the deposition of functionalized multi-walled carbon nanotubes (f-MWCNT) on the surface of the electrode followed by the electropolymerization of 1,8-DAN using cyclic voltammetry. The morphology and the electro-catalytic properties of the obtained electrodes were investigated with Fourier Transform Infrared Spectroscopy (FTIR), Transmission Electron Microscopy (TEM), Cyclic Voltammetry (CV), and Electrochemical Impedance Spectroscopy (EIS) showing an improvement of the electronic transfer due to the synergic effect between the proprieties of poly 1,8-DAN and f-MWCNT. Under the optimum experimental conditions, the poly 1,8-DAN/f-MWCNT/CPE exhibited excellent electro-catalytic activity towards nitrite detection. The nitrite anodic peak potential decreased by 210 mV compared to the bare carbon paste electrode. The calibration plot of nitrite detection was linear in the range of concentration from 300 to 6500 nM with a low detection limit of 75 nM.
Collapse
|
13
|
El Attar A, Chemchoub S, Diallo Kalan M, Oularbi L, El Rhazi M. Designing New Material Based on Functionalized Multi-Walled Carbon Nanotubes and Cu(OH)2–Cu2O/Polypyrrole Catalyst for Ethanol Oxidation in Alkaline Medium. Front Chem 2022; 9:805654. [PMID: 35186892 PMCID: PMC8854777 DOI: 10.3389/fchem.2021.805654] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Accepted: 12/28/2021] [Indexed: 11/13/2022] Open
Abstract
In this work, copper(II) hydroxide (Cu(OH)2) and copper oxide (Cu2O) nanostructures are deposited on functionalized multi-walled carbon nanotubes/polypyrrole to report an efficient electrocatalyst for ethanol oxidation in alkaline medium. In the first step, the deposition of functionalized multi-walled nanotubes of carbon (F-MWCNTs) on the electrode surface was carried out using drop casting mode followed by the electrodeposition of polypyrrole (PPy) and copper nanoparticles (Cu-Nps) using galvanostatic mode. Scanning electron microscopy (SEM) and X-ray diffraction (XRD) were performed in order to study the morphology and the structure of the elaborated catalysts. Electrochemical characterization conducted by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) revealed that the introduction of functionalized multi-walled carbon nanotubes enhances the electric properties of the nanocomposites and offers a large active surface area. The prepared electrocatalyst was then tested in a solution of 0.1 M NaOH containing 0.2 M of ethanol showing high performance (7 mA cm−2 at 0.85 V vs Ag/AgCl) and good stability (over 1800 s) toward ethanol oxidation.
Collapse
|
14
|
Jemai R, Djebbi MA, Hussain N, Yang B, Hirtz M, Trouillet V, Ben Rhaiem H, Ben Haj Amara A. Activated Porous Carbon Supported Pd and ZnO Nanocatalysts for Trace Sensing of Carbaryl Pesticide in Water and Food Products. NEW J CHEM 2022. [DOI: 10.1039/d2nj01844f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Nanomaterials-based sensors are a dire need for credible and accurate determination of pesticides in water and food samples as a monitoring tool. Herein, electrocatalysts of Pd and ZnO NPs supported...
Collapse
|
15
|
Khosravi-Hamoleh A, Cheraghizade M. Enhanced and selective electrochemical sensing of cephalexin using zeolite/CPE. NEW J CHEM 2022. [DOI: 10.1039/d2nj00731b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The electrochemical sensing of cephalexin was suggested using a modified electrode (zeolite/CPE). The designed electrode presents an enhanced, selective, stable, and reproducible sensing process.
Collapse
Affiliation(s)
| | - Mohsen Cheraghizade
- Advanced Surface Engineering and Nano Materials Research Center, Department of Electrical Engineering, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran
| |
Collapse
|
16
|
A Laser Reduced Graphene Oxide Grid Electrode for the Voltammetric Determination of Carbaryl. Molecules 2021; 26:molecules26165050. [PMID: 34443639 PMCID: PMC8401968 DOI: 10.3390/molecules26165050] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Revised: 07/30/2021] [Accepted: 08/02/2021] [Indexed: 11/17/2022] Open
Abstract
Laser-reduced graphene oxide (LRGO) on a polyethylene terephthalate (PET) substrate was prepared in one step to obtain the LRGO grid electrode for sensitive carbaryl determination. The grid form results in a grid distribution of different electrochemically active zones affecting the electroactive substance diffusion towards the electrode surface and increasing the electrochemical sensitivity for carbaryl determination. Carbaryl is electrochemically irreversibly oxidized at the secondary amine moiety of the molecule with the loss of one proton and one electron in the pH range from 5 to 7 by linear scan voltammetry (LSV) on the LRGO grid electrode with a scan rate of 300 mV/s. Some interference of the juice matrix molecules does not significantly affect the LSV oxidation current of carbaryl on the LRGO grid electrode after adsorptive accumulation without applied potential. The LRGO grid electrode can be used for LSV determination of carbaryl in fruit juices in the concentration range from 0.25 to 128 mg/L with LOD of 0.1 mg/L. The fabrication of the LRGO grid electrode opens up possibilities for further inexpensive monitoring of carbaryl in other fruit juices and fruits.
Collapse
|
17
|
Salhi O, Ez‐zine T, El Rhazi M. Hybrid Materials Based on Conducting Polymers for Nitrite Sensing: A Mini Review. ELECTROANAL 2021. [DOI: 10.1002/elan.202100033] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Ouissal Salhi
- Laboratory of Materials Membranes and Environment Morocco Faculty of Sciences and Technologies University Hassan II Casablanca P.B. 146 Mohammedia 20800 Morocco
| | - Tarik Ez‐zine
- Laboratory of Materials Membranes and Environment Morocco Faculty of Sciences and Technologies University Hassan II Casablanca P.B. 146 Mohammedia 20800 Morocco
| | - Mama El Rhazi
- Laboratory of Materials Membranes and Environment Morocco Faculty of Sciences and Technologies University Hassan II Casablanca P.B. 146 Mohammedia 20800 Morocco
| |
Collapse
|
18
|
Khosravi‐Hamoleh A, Abrishamkar M, Cheraghizade M. Simultaneous Electrochemical Sensing of Ceftriaxone and Piroxicam Using Zeolite Modified Electrode for Medical Applications. ELECTROANAL 2021. [DOI: 10.1002/elan.202100121] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
| | - Maryam Abrishamkar
- Department of Chemistry, Ahvaz Branch Islamic Azad University Ahvaz Iran
| | - Mohsen Cheraghizade
- Department of Electrical Engineering, Ahvaz Branch Islamic Azad University Ahvaz Iran
| |
Collapse
|
19
|
El Attar A, Oularbi L, Chemchoub S, El Rhazi M. Effect of electrochemical activation on the performance and stability of hybrid (PPy/Cu2O nanodendrites) for efficient ethanol oxidation in alkaline medium. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115042] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
20
|
Recent progress on electrochemical sensing strategies as comprehensive point-care method. MONATSHEFTE FUR CHEMIE 2021. [DOI: 10.1007/s00706-020-02732-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
21
|
Buledi JA, Shah ZUH, Mallah A, Solangi AR. Current Perspective and Developments in Electrochemical Sensors Modified with Nanomaterials for Environmental and Pharmaceutical Analysis. CURR ANAL CHEM 2020. [DOI: 10.2174/1573411016999201006122740] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Over the past few decades, environmental pollution has appeared to be one of the most crucial
global problems. The widespread intensification of numerous hazardous pollutants in the environment need the modern
researchers to develop viable, reproducible and cost-effective determination tools for the reliable environmental analysis.
The beneficial, as well as perilous, biological compounds are receiving growing interest due to their variable composition
which produces advantageous and toxic impacts on human and the environment. Several conventional analytical methods
have been established for the pharmaceutical and environmental analysis. However, certain drawbacks limited their
practices in the modern rapidly growing era of science and technology. The development of electrochemical sensors has
emerged as more beneficial and promising tool as against other traditional analytical approaches, in terms of simplicity,
cost-effectiveness, sensitivity, stability and reliability. Nonetheless, the over potential and low anodic/cathodic current
response are both considered as bottlenecks for the determination of electroactive entities exploiting electrochemical
sensors. Interestingly, these problems can be easily resolved by modifying the electrodes with a variety of conductive
materials, especially nanostructures.
Objective:
This review covers different electrochemical methods, reported in the literature, for the environmental and
pharmaceutical analysis through simple and cost-effective nanostructures-based sensors. The electrochemical techniques
with different modes and the modification of electrodes with highly conductive and prolific polymeric and nanostructured
materials used for the determination of different environmental and pharmaceutical samples are the main prominence of
this review. Various kinds of nanomaterials, e.g. metal, metal oxide and their composites, have been synthesized for the
fabrication of sensitive electrodes.
Conclusion:
Nanostructures played a pivotal role in the modification of electrodes, which substantially enhanced the
capability and sensitivity of electrochemical sensors. The proper modification of electrodes has materialized the swift
detection of electroactive compounds at very low limits and offered the feasible determination procedure without any kind
of signal fluctuation and over potential. In crux, due to their enhanced surface area and excellent catalytic properties,
nanomaterials recently appeared as the most promising candidates in the field of electrode modification and significantly
impacted the detection protocols for various environmental pollutants, viz. pesticides, metal ions and drugs.
Collapse
Affiliation(s)
- Jamil A. Buledi
- National Centre of Excellence in Analytical Chemistry, University of Sindh, 76080, Jamshoro, Pakistan
| | - Zia-ul-Hassan Shah
- Department of Soil Science, Sindh Agriculture University, Tandojam, Pakistan
| | - Arfana Mallah
- M.A. Kazi Institute of Chemistry, University of Sindh, 76080, Jamshoro, Pakistan
| | - Amber R. Solangi
- National Centre of Excellence in Analytical Chemistry, University of Sindh, 76080, Jamshoro, Pakistan
| |
Collapse
|
22
|
Festinger N, Morawska K, Ivanovski V, Ziąbka M, Jedlińska K, Ciesielski W, Smarzewska S. Comparative Electroanalytical Studies of Graphite Flake and Multilayer Graphene Paste Electrodes. SENSORS 2020; 20:s20061684. [PMID: 32197336 PMCID: PMC7146468 DOI: 10.3390/s20061684] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Revised: 03/14/2020] [Accepted: 03/16/2020] [Indexed: 01/17/2023]
Abstract
In this paper, the fabrication, surface characterisation and electrochemical properties of graphite flake (GFPE) and multilayer graphene (MLGPE) paste electrodes are described. The Raman investigations and scanning electron microscopy were used to analyze and compare structure of both carbon materials. The electroanalytical performance of both electrodes was examined and compared on the basis of the square-wave and cyclic voltammetric behavior of acetaminophen and model redox systems. Results of those studies revealed that GFPE has a larger electroactive surface area and better conductive properties, whilst MLGPE demonstrate better analytical characteristic in case of acetaminophen (AC) determination. AC determination was developed using square wave voltammetry (SWV) and square wave stripping voltammetry (SWSV). For both working electrodes, the process of accumulation enabled us to obtain an extended linear range and to lower the detection limit. In pharmaceutical formulations, AC was determined with good recovery.
Collapse
Affiliation(s)
- Natalia Festinger
- Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, 91-403 Lodz, Poland
- Correspondence: ; Tel.: +48-42-6355480
| | - Kamila Morawska
- Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, 91-403 Lodz, Poland
| | - Vladimir Ivanovski
- Institute of Chemistry, Faculty of Natural Sciences and Mathematics, University of Ss. Cyril and Methodius in Skopje, 1000 Skopje, Macedonia
| | - Magdalena Ziąbka
- Faculty of Materials Science and Ceramics, AGH University of Science and Technology, 30-059 Cracow, Poland
| | - Katarzyna Jedlińska
- Faculty of Materials Science and Ceramics, AGH University of Science and Technology, 30-059 Cracow, Poland
| | - Witold Ciesielski
- Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, 91-403 Lodz, Poland
| | - Sylwia Smarzewska
- Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, 91-403 Lodz, Poland
| |
Collapse
|
23
|
Zhang M, Zhang Z, Yang Y, Zhang Y, Wang Y, Chen X. Ratiometric Strategy for Electrochemical Sensing of Carbaryl Residue in Water and Vegetable Samples. SENSORS (BASEL, SWITZERLAND) 2020; 20:E1524. [PMID: 32164236 PMCID: PMC7085720 DOI: 10.3390/s20051524] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 03/01/2020] [Accepted: 03/06/2020] [Indexed: 11/16/2022]
Abstract
Accurate analysis of pesticide residue in real samples is essential for food safety and environmental protection. However, a traditional electrochemical sensor based on single-signal output is easily affected by background noise, environmental conditions, electrode diversity, and a complex matrix of samples, leading to extremely low accuracy. Hence, in this paper, a ratiometric strategy based on dual-signal output was adopted to build inner correction for sensing of widely-used carbaryl (CBL) for the first time. By comparison, Nile blue A (NB) was selected as reference probe, due to its well-defined peak, few effects on the target peak of CBL, and excellent stability. The effects of a derivatization method, technique mode, and pH were also investigated. Then the performance of the proposed ratiometric sensor was assessed in terms of three aspects including the elimination of system noise, electrode deviation and matrix effect. Compared with traditional single-signal sensor, the ratiometric sensor showed a much better linear correlation coefficient (r > 0.99), reproducibility (RSD < 10%), and limit of detection (LOD = 1.0 μM). The results indicated the introduction of proper reference probe could ensure the interdependence of target and reference signal on the same sensing environment, thus inner correction was fulfilled, which provided a promising tool for accurate analysis.
Collapse
Affiliation(s)
- Min Zhang
- College of Food Science and Engineering, Northwest A&F University, No.22 Xinong Road, Yangling 712100, China; (Z.Z.); (Y.Y.); (Y.Z.); (Y.W.); (X.C.)
| | | | | | | | | | | |
Collapse
|
24
|
Ranđelović MS, Momčilović MZ, Milićević JS, Đurović-Pejčev RD, Mofarah SS, Sorrel CC. Voltammetric sensor based on Pt nanoparticles suported MWCNT for determination of pesticide clomazone in water samples. J Taiwan Inst Chem Eng 2019. [DOI: 10.1016/j.jtice.2019.10.013] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
25
|
Hashemi P, Karimian N, Khoshsafar H, Arduini F, Mesri M, Afkhami A, Bagheri H. Reduced graphene oxide decorated on Cu/CuO-Ag nanocomposite as a high-performance material for the construction of a non-enzymatic sensor: Application to the determination of carbaryl and fenamiphos pesticides. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 102:764-772. [DOI: 10.1016/j.msec.2019.05.010] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2018] [Revised: 04/13/2019] [Accepted: 05/06/2019] [Indexed: 02/04/2023]
|
26
|
Soltani‐Shahrivar M, Karimian N, Fakhri H, Hajian A, Afkhami A, Bagheri H. Design and Application of a Non‐enzymatic Sensor Based on Metal‐organic Frameworks for the Simultaneous Determination of Carbofuran and Carbaryl in Fruits and Vegetables. ELECTROANAL 2019. [DOI: 10.1002/elan.201900363] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
| | - Nashmil Karimian
- Research and Development DepartmentFarin Behbood Tashkhis LTD Tehran Iran
| | - Hanieh Fakhri
- Chemical Injuries Research Center, Systems Biology and Poisonings InstituteBaqiyatallah University of Medical Sciences Tehran Iran
| | - Ali Hajian
- Institute of Sensor and Actuator SystemsTU Wien 1040 Vienna Austria
| | - Abbas Afkhami
- Faculty of ChemistryBu-Ali Sina University Hamedan Iran
| | - Hasan Bagheri
- Chemical Injuries Research Center, Systems Biology and Poisonings InstituteBaqiyatallah University of Medical Sciences Tehran Iran
| |
Collapse
|
27
|
Rahmani T, Bagheri H, Behbahani M, Hajian A, Afkhami A. Modified 3D Graphene-Au as a Novel Sensing Layer for Direct and Sensitive Electrochemical Determination of Carbaryl Pesticide in Fruit, Vegetable, and Water Samples. FOOD ANAL METHOD 2018. [DOI: 10.1007/s12161-018-1280-4] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
28
|
Nano carbon black-based screen printed sensor for carbofuran, isoprocarb, carbaryl and fenobucarb detection: application to grain samples. Talanta 2018; 186:389-396. [PMID: 29784378 DOI: 10.1016/j.talanta.2018.04.082] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Revised: 04/23/2018] [Accepted: 04/26/2018] [Indexed: 12/24/2022]
Abstract
An electrochemical screening assay for the detection of phenyl carbamates (i.e. carbaryl, carbofuran, isoprocarb and fenobucarb) was developed and applied to grains samples (i.e. durum wheat, soft wheat and maize). Nano carbon black (CB) was strategically employed to realize an effective, reproducible, fouling resistant, low cost, delocalisable screen printed sensor (CB-SPE). CB-SPEs morphology (SEM and FEM) and electrochemical property (CV and EIS) were studied. The final pesticides analysis protocol consist of: (i) extraction of the analyte (just by mixing), (ii) alkaline hydrolysis (10 min R.T.), (iii) DPV detection directly of 100 µL of extract on the CB-SPE surface. Linear range between 1.0 × 10-7 and 1.0 × 10-4 mol L-1, good determination coefficients (R2 ≥ 0.9971) and satisfactory sensitivity (≥ 3.90 × 10-1 A M-1 cm-2) and LODs (≤ 8.0 × 10-8 mol L-1) were obtained for all the analytes. Excellent recoveries (78-102%) and accuracy (relative error vs. HPLC-MS/MS between 9.0% and -7.8%) resulted from the analysis of grains samples. The proposed CB-SPE based approach has demonstrated to be able to detect carbaryl at Maximum residue limits levels (MRLs), allowing class selective detection of commonly employed phenyl carbamates in food samples.
Collapse
|
29
|
Salih FE, Oularbi L, Halim E, Elbasri M, Ouarzane A, El Rhazi M. Conducting Polymer/Ionic Liquid Composite Modified Carbon Paste Electrode for the Determination of Carbaryl in Real Samples. ELECTROANAL 2018. [DOI: 10.1002/elan.201800152] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Fatima Ezzahra Salih
- Laboratory of Materials, Membranes and Environment, Faculty of sciences and Technologies -BP 146 Mohammedia 20650; University Hassan II of Casablanca; Morocco
| | - Larbi Oularbi
- Laboratory of Materials, Membranes and Environment, Faculty of sciences and Technologies -BP 146 Mohammedia 20650; University Hassan II of Casablanca; Morocco
| | - El Halim
- Laboratory of Materials, Membranes and Environment, Faculty of sciences and Technologies -BP 146 Mohammedia 20650; University Hassan II of Casablanca; Morocco
| | - Miloud Elbasri
- Laboratory of Materials, Membranes and Environment, Faculty of sciences and Technologies -BP 146 Mohammedia 20650; University Hassan II of Casablanca; Morocco
| | - Aicha Ouarzane
- Laboratory of Materials, Membranes and Environment, Faculty of sciences and Technologies -BP 146 Mohammedia 20650; University Hassan II of Casablanca; Morocco
| | - Mama El Rhazi
- Laboratory of Materials, Membranes and Environment, Faculty of sciences and Technologies -BP 146 Mohammedia 20650; University Hassan II of Casablanca; Morocco
| |
Collapse
|