1
|
Vergara-Barberán M, Lerma-García MJ, Simó-Alfonso EF, Herrero-Martínez JM. Galactose-functionalized methacrylate polymers as affinity sorbents for extraction of food allergen lectins. Anal Chim Acta 2023; 1255:341142. [PMID: 37032057 DOI: 10.1016/j.aca.2023.341142] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 03/14/2023] [Accepted: 03/23/2023] [Indexed: 03/31/2023]
Abstract
In this study, glycidyl methacrylate (GMA)-based materials functionalized with different galactose derivatives were prepared to be used as affinity sorbents for solid-phase extraction (SPE) of several food allergen lectins (such as phytohemagglutinin (PHA)). First, GMA-based polymers were synthesized and then galactose derivatives were immobilized onto the GMA surface using two different synthetic routes. In the first approach, the bare polymer was modified with ethylenediamine and glutaraldehyde, and subsequently two galactose derivatives were immobilized. In the second strategy, the starting polymer was modified with cystamine and gold nanoparticles (AuNPs), on which a thiolated galactose derivative was subsequently anchored. The resulting materials were characterized by scanning electron microscopy and used as SPE sorbents for the isolation of PHA (as probe protein) from food matrices. Different SPE parameters (sample pH, eluent solution composition, binding capacity, sample volume, selectivity and reusability) were evaluated. The material that provided the best PHA recovery (98%) was the one obtained in the second approach, being this material successfully applied to the selective extraction of PHA and other similar lectins from different foods (red and lima dried beans, fresh soybeans and biscuits containing soybean protein traces as indicated in their label). After SDS-PAGE of eluates, all samples only exhibited the characteristic PHA band around 30 kDa, suggesting the high potential of the developed material for application in food allergy field.
Collapse
|
2
|
Gupta A, Gupta GS. Applications of mannose-binding lectins and mannan glycoconjugates in nanomedicine. JOURNAL OF NANOPARTICLE RESEARCH : AN INTERDISCIPLINARY FORUM FOR NANOSCALE SCIENCE AND TECHNOLOGY 2022; 24:228. [PMID: 36373057 PMCID: PMC9638366 DOI: 10.1007/s11051-022-05594-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 10/12/2022] [Indexed: 06/01/2023]
Abstract
UNLABELLED Glycosylated nanoparticles (NPs) have drawn a lot of attention in the biomedical field over the past few decades, particularly in applications like targeted drug delivery. Mannosylated NPs and mannan-binding lectins/proteins (MBL/MBP) are emerging as promising tools for delivery of drugs, medicines, and enzymes to targeted tissues and cells as nanocarriers, enhancing their therapeutic benefits while avoiding the adverse effects of the drug. The occurrence of plenty of lectin receptors and their mannan ligands on cell surfaces makes them multifaceted carriers appropriate for specific delivery of bioactive drug materials to their targeted sites. Thus, the present review describes the tethering of mannose (Man) to several nanostructures, like micelles, liposomes, and other NPs, applicable for drug delivery systems. Bioadhesion through MBL-like receptors on cells has involvements applicable to additional arenas of science, for example gene delivery, tissue engineering, biomaterials, and nanotechnology. This review also focuses on the role of various aspects of drug/antigen delivery using (i) mannosylated NPs, (ii) mannosylated lectins, (iii) amphiphilic glycopolymer NPs, and (iv) natural mannan-containing polysaccharides, with most significant applications of MBL-based NPs as multivalent scaffolds, using different strategies. GRAPHICAL ABSTRACT Mannosylated NPs and/or MBL/MBP are coming up as viable and versatile tools as nanocarriers to deliver drugs and enzymes precisely to their target tissues or cells. The presence of abundant number of lectin receptors and their mannan ligands on cell surfaces makes them versatile carriers suitable for the targeted delivery of bioactive drugs.
Collapse
Affiliation(s)
- Anita Gupta
- Chitkara School of Health Sciences, Chitkara University, Punjab, India
| | - G. S. Gupta
- Department of Biophysics, Panjab University, Chandigarh, 160014 India
| |
Collapse
|
3
|
Poddar S, Sharmeen S, Hage DS. Affinity monolith chromatography: A review of general principles and recent developments. Electrophoresis 2021; 42:2577-2598. [PMID: 34293192 DOI: 10.1002/elps.202100163] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/07/2021] [Accepted: 07/18/2021] [Indexed: 12/28/2022]
Abstract
Affinity monolith chromatography (AMC) is a liquid chromatographic technique that utilizes a monolithic support with a biological ligand or related binding agent to isolate, enrich, or detect a target analyte in a complex matrix. The target-specific interaction exhibited by the binding agents makes AMC attractive for the separation or detection of a wide range of compounds. This article will review the basic principles of AMC and recent developments in this field. The supports used in AMC will be discussed, including organic, inorganic, hybrid, carbohydrate, and cryogel monoliths. Schemes for attaching binding agents to these monoliths will be examined as well, such as covalent immobilization, biospecific adsorption, entrapment, molecular imprinting, and coordination methods. An overview will then be given of binding agents that have recently been used in AMC, along with their applications. These applications will include bioaffinity chromatography, immunoaffinity chromatography, immobilized metal-ion affinity chromatography, and dye-ligand or biomimetic affinity chromatography. The use of AMC in chiral separations and biointeraction studies will also be discussed.
Collapse
Affiliation(s)
- Saumen Poddar
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, 68588, USA
| | - Sadia Sharmeen
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, 68588, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, 68588, USA
| |
Collapse
|
4
|
Wang J, Guo J, Chen H, Huang X, Somsen GW, Song F, Jiang Z. A single-step preparation of carbohydrate functionalized monoliths for separation and trapping of polar compounds. J Chromatogr A 2020; 1628:461481. [DOI: 10.1016/j.chroma.2020.461481] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2020] [Revised: 08/10/2020] [Accepted: 08/12/2020] [Indexed: 12/19/2022]
|
5
|
Development of a metal/chelate polyhydroxyethylmethacrylate monolith capillary for selective depletion of immunoglobulin G from human plasma for proteomics. J Chromatogr A 2017; 1517:117-125. [DOI: 10.1016/j.chroma.2017.08.047] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Revised: 07/17/2017] [Accepted: 08/17/2017] [Indexed: 02/03/2023]
|
6
|
Khaparde A, M. A. V, Tetala KKR. Preparation and characterization of a Cu (II)-IDA poly HEMA monolith syringe for proteomic applications. Electrophoresis 2017; 38:2981-2984. [DOI: 10.1002/elps.201700219] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2017] [Revised: 07/26/2017] [Accepted: 07/27/2017] [Indexed: 01/08/2023]
Affiliation(s)
- Ashish Khaparde
- Advanced centre for Bioseparation Technology (CBST); VIT University; Vellore Tamil Nadu India
| | - Vijayalakshmi M. A.
- Advanced centre for Bioseparation Technology (CBST); VIT University; Vellore Tamil Nadu India
| | - Kishore K. R. Tetala
- Advanced centre for Bioseparation Technology (CBST); VIT University; Vellore Tamil Nadu India
| |
Collapse
|
7
|
Wolfel A, Romero MR, Alvarez Igarzabal CI. Post-synthesis modification of hydrogels. Total and partial rupture of crosslinks: Formation of aldehyde groups and re-crosslinking of cleaved hydrogels. POLYMER 2017. [DOI: 10.1016/j.polymer.2017.03.068] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
8
|
Biocompatible chiral monolithic stationary phase synthesized via atom transfer radical polymerization for high performance liquid chromatographic analysis. J Chromatogr A 2015. [DOI: 10.1016/j.chroma.2015.07.042] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
9
|
Tan YH, Fujikawa K, Pornsuriyasak P, Alla AJ, Ganesh NV, Demchenko AV, Stine KJ. Lectin-carbohydrate interactions on nanoporous gold monoliths. NEW J CHEM 2013; 37:2150-2165. [PMID: 24883017 PMCID: PMC4038695 DOI: 10.1039/c3nj00253e] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
Monoliths of nanoporous gold (np-Au) were modified with self-assembled monolayers of octadecanethiol (C18-SH), 8-mercaptooctyl α-D-mannopyranoside (αMan-C8-SH), and 8-mercapto-3,6-dioxaoctanol (HO-PEG2-SH), and the loading was assessed using thermogravimetric analysis (TGA). Modification with mixed SAMs containing αMan-C8-SH (at a 0.20 mole fraction in the SAM forming solution) with either octanethiol or HO-PEG2-SH was also investigated. The np-Au monoliths modified with αMan-C8-SH bind the lectin Concanavalin A (Con A), and the additional mass due to bound protein was assessed using TGA analysis. A comparison of TGA traces measured before and after exposure of HO-PEG2-SH modified np-Au to Con A showed that the non-specific binding of Con A was minimal. In contrast, np-Au modified with octanethiol showed a significant mass loss due to non-specifically adsorbed Con A. A significant mass loss was also attributed to binding of Con A to bare np-Au monoliths. TGA revealed a mass loss due to the binding of Con A to np-Au monoliths modified with pure αMan-C8-SH. The use of mass losses determined by TGA to compare the binding of Con A to np-Au monoliths modified by mixed SAMs of αMan-C8-SH and either octanethiol or HO-PEG2-SH revealed that binding to mixed SAM modified surfaces is specific for the mixed SAMs with HO-PEG2-SH but shows a significant contribution from non-specific adsorption for the mixed SAMs with octanethiol. Minimal adsorption of immunoglobulin G (IgG) and peanut agglutinin (PNA) towards the mannoside modified np-Au monoliths was demonstrated. A greater mass loss was found for Con A bound onto the monolith than for either IgG or PNA, signifying that the mannose presenting SAMs in np-Au retain selectivity for Con A. TGA data also provide evidence that Con A bound to the αMan-C8-SH modified np-Au can be eluted by flowing a solution of methyl α-D-mannopyranoside through the structure. The presence of Con A proteins on the modified np-Au surface was also confirmed using atomic force microscopy (AFM). The results highlight the potential for application of carbohydrate modified np-Au monoliths to glycoscience and glycotechnology and demonstrate that they can be used for capture and release of carbohydrate binding proteins in significant quantities.
Collapse
Affiliation(s)
- Yih Horng Tan
- Department of Chemistry and Biochemistry, University of Missouri – Saint Louis, Saint Louis, MO 63121, USA
- UM-St. Louis Center for Nanoscience, University of Missouri – Saint Louis, Saint Louis, MO 63121, USA
| | - Kohki Fujikawa
- Department of Chemistry and Biochemistry, University of Missouri – Saint Louis, Saint Louis, MO 63121, USA
| | - Papapida Pornsuriyasak
- Department of Chemistry and Biochemistry, University of Missouri – Saint Louis, Saint Louis, MO 63121, USA
| | - Allan J. Alla
- Department of Chemistry and Biochemistry, University of Missouri – Saint Louis, Saint Louis, MO 63121, USA
- UM-St. Louis Center for Nanoscience, University of Missouri – Saint Louis, Saint Louis, MO 63121, USA
| | - N. Vijaya Ganesh
- Department of Chemistry and Biochemistry, University of Missouri – Saint Louis, Saint Louis, MO 63121, USA
| | - Alexei V. Demchenko
- Department of Chemistry and Biochemistry, University of Missouri – Saint Louis, Saint Louis, MO 63121, USA
| | - Keith J. Stine
- Department of Chemistry and Biochemistry, University of Missouri – Saint Louis, Saint Louis, MO 63121, USA
- UM-St. Louis Center for Nanoscience, University of Missouri – Saint Louis, Saint Louis, MO 63121, USA
| |
Collapse
|
10
|
Pfaunmiller EL, Paulemond ML, Dupper CM, Hage DS. Affinity monolith chromatography: a review of principles and recent analytical applications. Anal Bioanal Chem 2013; 405:2133-45. [PMID: 23187827 PMCID: PMC3578177 DOI: 10.1007/s00216-012-6568-4] [Citation(s) in RCA: 81] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2012] [Accepted: 11/12/2012] [Indexed: 10/27/2022]
Abstract
Affinity monolith chromatography (AMC) is a type of liquid chromatography that uses a monolithic support and a biologically related binding agent as a stationary phase. AMC is a powerful method for the selective separation, analysis, or study of specific target compounds in a sample. This review discusses the basic principles of AMC and recent developments and applications of this method, with particular emphasis being given to work that has appeared in the last 5 years. Various materials that have been used to prepare columns for AMC are examined, including organic monoliths, silica monoliths, agarose monoliths, and cryogels. These supports have been used in AMC for formats that have ranged from traditional columns to disks, microcolumns, and capillaries. Many binding agents have also been employed in AMC, such as antibodies, enzymes, proteins, lectins, immobilized metal ions, and dyes. Some applications that have been reported with these binding agents in AMC are bioaffinity chromatography, immunoaffinity chromatography or immunoextraction, immobilized-metal-ion affinity chromatography, dye-ligand affinity chromatography, chiral separations, and biointeraction studies. Examples are presented from fields that include analytical chemistry, pharmaceutical analysis, clinical testing, and biotechnology. Current trends and possible directions in AMC are also discussed.
Collapse
Affiliation(s)
| | | | - Courtney M. Dupper
- Department of Chemistry University of Nebraska Lincoln, NE 68588-0304, USA
| | - David S. Hage
- Department of Chemistry University of Nebraska Lincoln, NE 68588-0304, USA
| |
Collapse
|
11
|
Sproß J, Sinz A. Monolithic media for applications in affinity chromatography. J Sep Sci 2011; 34:1958-73. [DOI: 10.1002/jssc.201100400] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2011] [Revised: 05/19/2011] [Accepted: 05/19/2011] [Indexed: 11/10/2022]
|
12
|
Tetala KKR, Heikema AP, Pukin AV, Weijers CAGM, Tio-Gillen AP, Gilbert M, Endtz HP, van Belkum A, Zuilhof H, Visser GM, Jacobs BC, van Beek TA. Selective Depletion of Neuropathy-Related Antibodies from Human Serum by Monolithic Affinity Columns Containing Ganglioside Mimics. J Med Chem 2011; 54:3500-5. [DOI: 10.1021/jm101594s] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Kishore K. R. Tetala
- Laboratory of Organic Chemistry, Wageningen University, Dreijenplein 8, 6703 HB Wageningen, The Netherlands
| | - Astrid P. Heikema
- Department of Neurology and Immunology, Erasmus MC, University Medical Centre, P.O. Box 2040, 3000 CA Rotterdam, The Netherlands
| | - Aliaksei V. Pukin
- Laboratory of Organic Chemistry, Wageningen University, Dreijenplein 8, 6703 HB Wageningen, The Netherlands
| | - Carel A. G. M. Weijers
- Laboratory of Organic Chemistry, Wageningen University, Dreijenplein 8, 6703 HB Wageningen, The Netherlands
| | - Anne P. Tio-Gillen
- Department of Neurology and Immunology, Erasmus MC, University Medical Centre, P.O. Box 2040, 3000 CA Rotterdam, The Netherlands
| | - Michel Gilbert
- Institute for Biological Sciences, National Research Council Canada, Ottawa, Ontario K1A 0R6, Canada
| | - Hubert P. Endtz
- Department of Neurology and Immunology, Erasmus MC, University Medical Centre, P.O. Box 2040, 3000 CA Rotterdam, The Netherlands
| | - Alex van Belkum
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC, University Medical Centre, 's-Gravendijksewal 230, 3015 CE Rotterdam, The Netherlands
| | - Han Zuilhof
- Laboratory of Organic Chemistry, Wageningen University, Dreijenplein 8, 6703 HB Wageningen, The Netherlands
| | - Gerben M. Visser
- Laboratory of Organic Chemistry, Wageningen University, Dreijenplein 8, 6703 HB Wageningen, The Netherlands
| | - Bart C. Jacobs
- Department of Neurology and Immunology, Erasmus MC, University Medical Centre, P.O. Box 2040, 3000 CA Rotterdam, The Netherlands
| | - Teris A. van Beek
- Laboratory of Organic Chemistry, Wageningen University, Dreijenplein 8, 6703 HB Wageningen, The Netherlands
| |
Collapse
|
13
|
Abstract
Affinity chromatography on monolithic supports is a powerful analytical chemical platform because it allows for fast analyses, small sample volumes, strong enrichment of trace biomarkers and applications in microchips. In this review, the recent research using monolithic materials in the field of bioaffinity chromatography (including immunochromatography) is summarized and discussed. After giving an introduction into affinity chromatography, information on different biomolecules (antibodies, enzymes, lectins, aptamers) that can act as ligands in bioaffinity chromatography is presented. Subsequently, the history of monoliths, their advantages, preparation and formats (disks, capillaries and microchips) as well as ligand immobilization techniques are mentioned. Finally, analytical and preparative applications of bioaffinity chromatography on monoliths are presented. During the last four years 37 papers appeared. Protein A and G are still most often used as ligands for the enrichment of immunoglobulins. Antibodies and lectins remain popular for the analysis of mainly smaller molecules and saccharides, respectively. The highly porous cryogels modified with ligands are applied for the sorting of different cells or bacteria. New is the application of aptamers and phages as ligands on monoliths. Convective interaction media (epoxy CIM disks) are currently the most used format in monolithic bioaffinity chromatography.
Collapse
Affiliation(s)
- Kishore K R Tetala
- Laboratory of Organic Chemistry, Natural Products Chemistry Group, Wageningen University, Wageningen, The Netherlands.
| | | |
Collapse
|
14
|
Separation of Immunoglobulin G and Immunoglobulin Y on Poly(vinyl ester resin-co-ethylene dimethacrylate) Monolith. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2009. [DOI: 10.1016/s1872-2040(08)60090-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
15
|
Zhang J, Shi J, Ilic S, Jun Xue S, Kakuda Y. Biological Properties and Characterization of Lectin from Red Kidney Bean (Phaseolus Vulgaris). FOOD REVIEWS INTERNATIONAL 2008. [DOI: 10.1080/87559120802458115] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
16
|
Urban J, Jandera P. Polymethacrylate monolithic columns for capillary liquid chromatography. J Sep Sci 2008; 31:2521-40. [DOI: 10.1002/jssc.200800182] [Citation(s) in RCA: 112] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
17
|
Wu R, Hu L, Wang F, Ye M, Zou H. Recent development of monolithic stationary phases with emphasis on microscale chromatographic separation. J Chromatogr A 2008; 1184:369-92. [DOI: 10.1016/j.chroma.2007.09.022] [Citation(s) in RCA: 232] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2007] [Revised: 09/06/2007] [Accepted: 09/11/2007] [Indexed: 12/28/2022]
|
18
|
Tetala KKR, Chen B, Visser GM, van Beek TA. Single step synthesis of carbohydrate monolithic capillary columns for affinity chromatography of lectins. J Sep Sci 2007; 30:2828-35. [DOI: 10.1002/jssc.200700356] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|