1
|
Collagen-Based Electrospun Materials for Tissue Engineering: A Systematic Review. Bioengineering (Basel) 2021; 8:bioengineering8030039. [PMID: 33803598 PMCID: PMC8003061 DOI: 10.3390/bioengineering8030039] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 03/11/2021] [Accepted: 03/12/2021] [Indexed: 12/14/2022] Open
Abstract
Collagen is a key component of the extracellular matrix (ECM) in organs and tissues throughout the body and is used for many tissue engineering applications. Electrospinning of collagen can produce scaffolds in a wide variety of shapes, fiber diameters and porosities to match that of the native ECM. This systematic review aims to pool data from available manuscripts on electrospun collagen and tissue engineering to provide insight into the connection between source material, solvent, crosslinking method and functional outcomes. D-banding was most often observed in electrospun collagen formed using collagen type I isolated from calfskin, often isolated within the laboratory, with short solution solubilization times. All physical and chemical methods of crosslinking utilized imparted resistance to degradation and increased strength. Cytotoxicity was observed at high concentrations of crosslinking agents and when abbreviated rinsing protocols were utilized. Collagen and collagen-based scaffolds were capable of forming engineered tissues in vitro and in vivo with high similarity to the native structures.
Collapse
|
2
|
Heraud S, Delalleau A, Houcine A, Guiraud B, Bacqueville D, Payre B, Delisle MB, Bessou-Touya S, Damour O. Structural and Biomechanical Characterization of a Scaffold-Free Skin Equivalent Model via Biophysical Methods. Skin Pharmacol Physiol 2019; 33:17-29. [PMID: 31852002 DOI: 10.1159/000503154] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Accepted: 09/02/2019] [Indexed: 11/19/2022]
Abstract
AIMS Among in vitro skin models, the scaffold-free skin equivalent (SFSE), without exogenous material, is interesting for pharmacotoxicological studies. Our aim was to adapt in vivo biophysical methods to study the structure, thickness, and extracellular matrix of our in vitro model without any chemical fixation needed as for histology. METHODS We evaluated 3 batches of SFSE and characterized them by histology, transmission electron microscopy (TEM), and immunofluorescence. In parallel, we investigated 3 biophysical methods classically used for in vivo evaluation, optical coherence tomography (OCT), and laser scanning microscopy (LSM) imaging devices as well as the cutometer suction to study the biomechanical properties. RESULTS OCT allowed the evaluation of SFSE total thickness and its different compartments. LSM has a greater resolution enabling an evaluation at the cell scale and the orientation of collagen fibers. The viscoelasticity measurement by cutometry was possible on our thin skin model and might be linked with mature collagen bundles visible in TEM and LSM and with elastic fibers seen in immunofluorescence. CONCLUSION Our data demonstrated the simplicity and sensitivity of these different in vivo biophysical devices on our thin skin model. These noninvasive tools allow to study the morphology and the biomechanics of in vitro models.
Collapse
Affiliation(s)
- Sandrine Heraud
- Banque de Tissus et Cellules, Hospices Civils de Lyon and LBTI, UMR 5305, Lyon, France, .,Pierre Fabre, R&D PFDC, Département Pharmacologie, Toulouse, France,
| | | | - Audrey Houcine
- Centre de Microscopie Electronique Appliquée à la Biologie, Faculté de Médecine Rangueil, Toulouse, France
| | - Béatrice Guiraud
- Pierre Fabre, R&D PFDC, Département Pharmacologie, Toulouse, France
| | | | - Bruno Payre
- Centre de Microscopie Electronique Appliquée à la Biologie, Faculté de Médecine Rangueil, Toulouse, France
| | - Marie-Bernadette Delisle
- Centre de Microscopie Electronique Appliquée à la Biologie, Faculté de Médecine Rangueil, Toulouse, France.,CHU Toulouse and INSERM U 1037, Toulouse, France
| | | | - Odile Damour
- Banque de Tissus et Cellules, Hospices Civils de Lyon and LBTI, UMR 5305, Lyon, France
| |
Collapse
|
3
|
Inflammatory response and biomechanical properties of coaxial scaffolds for engineered skin in vitro and post-grafting. Acta Biomater 2018; 80:247-257. [PMID: 30218778 DOI: 10.1016/j.actbio.2018.09.014] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2018] [Revised: 08/30/2018] [Accepted: 09/11/2018] [Indexed: 12/19/2022]
Abstract
Engineered skin (ES) offers many advantages over split-thickness skin autografts for the treatment of burn wounds. However, ES, both in vitro and after grafting, is often significantly weaker, less elastic and more compliant than normal human skin. Biomechanical properties of ES can be tuned in vitro using electrospun co-axial (CoA) scaffolds. To explore the potential for coaxial scaffold-based ES use in vivo, two CoA scaffolds were fabricated with bioactive gelatin shells and biodegradable synthetic cores of polylactic acid (PLA) and polycaprolactone (PCL), and compared with gelatin monofilament scaffolds. Fibroblast and macrophage production of inflammatory cytokines interleukin 6 (IL-6) and transforming growth factor β-1 was significantly higher when cultured on PLA and PCL monofilament scaffolds compared to gelatin monofilament scaffolds. The core-shell fiber configuration significantly reduced production of pro-inflammatory cytokines to levels similar to those of gelatin monofilament scaffolds. In vitro, ES mechanical properties were significantly enhanced using CoA scaffolds; however, after grafting CoA- and gelatin-based ES to full-thickness excisional wounds on athymic mice, the in vitro mechanical advantage of CoA grafts was lost. A substantially increased inflammatory response to CoA-based ES was observed, with upregulation of IL-6 expression and a significant M2 macrophage presence. Additionally, expression of matrix metalloproteinase I was upregulated and collagen type I alpha 1 was downregulated in CoA ES two weeks after grafting. These results suggest that while coaxial scaffolds provide the ability to regulate biomechanics in vitro, further investigation of the inflammatory response to core materials is required to optimize this strategy for clinical use. STATEMENT OF SIGNIFICANCE: Engineered skin has been used to treat very large burn injuries. Despite its ability to heal these wounds, engineered skin exhibits reduced biomechanical properties making it challenging to manufacture and surgically apply. Coaxial fiber scaffolds have been utilized to tune the mechanical properties of engineered skin while maintaining optimal biological properties but it is not known how these perform on a patient especially with regards to their inflammatory response. The current study examines the biomechanical and inflammatory properties of coaxial scaffolds and uniaxial scaffolds in vitro and in vivo. The results show that the biological response to the scaffold materials is a critical determinant of tissue properties after grafting with reduced inflammation and rapid scaffold remodeling leading to stronger skin.
Collapse
|
4
|
Tupin S, Molimard J, Cenizo V, Hoc T, Sohm B, Zahouani H. Multiscale Approach to Characterize Mechanical Properties of Tissue Engineered Skin. Ann Biomed Eng 2016; 44:2851-62. [PMID: 26942585 DOI: 10.1007/s10439-016-1576-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2015] [Accepted: 02/18/2016] [Indexed: 10/22/2022]
Abstract
Tissue engineered skin usually consist of a multi-layered visco-elastic material composed of a fibrillar matrix and cells. The complete mechanical characterization of these tissues has not yet been accomplished. The purpose of this study was to develop a multiscale approach to perform this characterization in order to link the development process of a cultured skin to the mechanical properties. As a proof-of-concept, tissue engineered skin samples were characterized at different stages of manufacturing (acellular matrix, reconstructed dermis and reconstructed skin) for two different aging models (using cells from an 18- and a 61-year-old man). To assess structural variations, bi-photonic confocal microscopy was used. To characterize mechanical properties at a macroscopic scale, a light-load micro-mechanical device that performs indentation and relaxation tests was designed. Finally, images of the internal network of the samples under stretching were acquired by combining confocal microscopy with a tensile device. Mechanical properties at microscopic scale were assessed. Results revealed that adding cells during manufacturing induced structural changes, which provided higher elastic modulus and viscosity. Moreover, senescence models exhibited lower elastic modulus and viscosity. This multiscale approach was efficient to characterize and compare skin equivalent samples and permitted the first experimental assessment of the Poisson's ratio for such tissues.
Collapse
Affiliation(s)
- S Tupin
- Laboratoire de Tribologie et Dynamique des Systèmes (LTDS, CNRS UMR5513), Université de Lyon, Ecole Centrale de Lyon, ENISE, 69134, Ecully, France
| | - J Molimard
- Ecole Nationale Supérieure des Mines, CIS-EMSE, INSERM UMR1059, SAINBIOSE, 42023, Saint-Etienne, France
| | - V Cenizo
- BASF Beauty Care Solutions France S.A.S, 69366, Lyon Cedex 07, France
| | - T Hoc
- Laboratoire de Tribologie et Dynamique des Systèmes (LTDS, CNRS UMR5513), Université de Lyon, Ecole Centrale de Lyon, ENISE, 69134, Ecully, France
| | - B Sohm
- BASF Beauty Care Solutions France S.A.S, 69366, Lyon Cedex 07, France
| | - H Zahouani
- Laboratoire de Tribologie et Dynamique des Systèmes (LTDS, CNRS UMR5513), Université de Lyon, Ecole Centrale de Lyon, ENISE, 69134, Ecully, France.
| |
Collapse
|
5
|
Sander EA, Lynch KA, Boyce ST. Development of the mechanical properties of engineered skin substitutes after grafting to full-thickness wounds. J Biomech Eng 2015; 136:051008. [PMID: 24356985 DOI: 10.1115/1.4026290] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2013] [Indexed: 11/08/2022]
Abstract
Engineered skin substitutes (ESSs) have been reported to close full-thickness burn wounds but are subject to loss from mechanical shear due to their deficiencies in tensile strength and elasticity. Hypothetically, if the mechanical properties of ESS matched those of native skin, losses due to shear or fracture could be reduced. To consider modifications of the composition of ESS to improve homology with native skin, biomechanical analyses of the current composition of ESS were performed. ESSs consist of a degradable biopolymer scaffold of type I collagen and chondroitin-sulfate (CGS) that is populated sequentially with cultured human dermal fibroblasts (hF) and epidermal keratinocytes (hK). In the current study, the hydrated biopolymer scaffold (CGS), the scaffold populated with hF dermal skin substitute (DSS), or the complete ESS were evaluated mechanically for linear stiffness (N/mm), ultimate tensile load at failure (N), maximum extension at failure (mm), and energy absorbed up to the point of failure (N-mm). These biomechanical end points were also used to evaluate ESS at six weeks after grafting to full-thickness skin wounds in athymic mice and compared to murine autograft or excised murine skin. The data showed statistically significant differences (p <0.05) between ESS in vitro and after grafting for all four structural properties. Grafted ESS differed statistically from murine autograft with respect to maximum extension at failure, and from intact murine skin with respect to linear stiffness and maximum extension. These results demonstrate rapid changes in mechanical properties of ESS after grafting that are comparable to murine autograft. These values provide instruction for improvement of the biomechanical properties of ESS in vitro that may reduce clinical morbidity from graft loss.
Collapse
|
6
|
Rheological behaviour of reconstructed skin. J Mech Behav Biomed Mater 2014; 37:251-63. [DOI: 10.1016/j.jmbbm.2014.05.030] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2014] [Revised: 05/16/2014] [Accepted: 05/27/2014] [Indexed: 12/11/2022]
|
7
|
Blackstone BN, Drexler JW, Powell HM. Tunable engineered skin mechanics via coaxial electrospun fiber core diameter. Tissue Eng Part A 2014; 20:2746-55. [PMID: 24712409 DOI: 10.1089/ten.tea.2013.0687] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023] Open
Abstract
Autologous engineered skin (ES) offers promise as a treatment for massive full thickness burns. Unfortunately, ES is orders of magnitude weaker than normal human skin causing it to be difficult to apply surgically and subject to damage by mechanical shear in the early phases of engraftment. In addition, no manufacturing strategy has been developed to tune ES biomechanics to approximate the native biomechanics at different anatomic locations. To enhance and tune ES biomechanics, a coaxial (CoA) electrospun scaffold platform was developed from polycaprolactone (PCL, core) and gelatin (shell). The ability of the coaxial fiber core diameter to control both scaffold and tissue mechanics was investigated along with the ability of the gelatin shell to facilitate cell adhesion and skin development compared to pure gelatin, pure PCL, and a gelatin-PCL blended fiber scaffold. CoA ES exhibited increased cellular adhesion and metabolism versus PCL alone or gelatin-PCL blend and promoted the development of well stratified skin with a dense dermal layer and a differentiated epidermal layer. Biomechanics of the scaffold and ES scaled linearly with core diameter suggesting that this scaffold platform could be utilized to tailor ES mechanics for their intended grafting site and reduce graft damage in vitro and in vivo.
Collapse
|
8
|
Hu Y, Liu L, Dan W, Dan N, Gu Z, Yu X. Synergistic effect of carbodiimide and dehydrothermal crosslinking on acellular dermal matrix. Int J Biol Macromol 2013; 55:221-30. [DOI: 10.1016/j.ijbiomac.2013.01.009] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2012] [Accepted: 01/11/2013] [Indexed: 10/27/2022]
|
9
|
Willard JJ, Drexler JW, Das A, Roy S, Shilo S, Shoseyov O, Powell HM. Plant-derived human collagen scaffolds for skin tissue engineering. Tissue Eng Part A 2013; 19:1507-18. [PMID: 23298216 DOI: 10.1089/ten.tea.2012.0338] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Tissue engineering scaffolds are commonly formed using proteins extracted from animal tissues, such as bovine hide. Risks associated with the use of these materials include hypersensitivity and pathogenic contamination. Human-derived proteins lower the risk of hypersensitivity, but possess the risk of disease transmission. Methods engineering recombinant human proteins using plant material provide an alternate source of these materials without the risk of disease transmission or concerns regarding variability. To investigate the utility of plant-derived human collagen (PDHC) in the development of engineered skin (ES), PDHC and bovine hide collagen were formed into tissue engineering scaffolds using electrospinning or freeze-drying. Both raw materials were easily formed into two common scaffold types, electrospun nonwoven scaffolds and lyophilized sponges, with similar architectures. The processing time, however, was significantly lower with PDHC. PDHC scaffolds supported primary human cell attachment and proliferation at an equivalent or higher level than the bovine material. Interleukin-1 beta production was significantly lower when activated THP-1 macrophages where exposed to PDHC electrospun scaffolds compared to bovine collagen. Both materials promoted proper maturation and differentiation of ES. These data suggest that PDHC may provide a novel source of raw material for tissue engineering with low risk of allergic response or disease transmission.
Collapse
Affiliation(s)
- James J Willard
- Department of Materials Science and Engineering, The Ohio State University, Columbus, Ohio 43210, USA
| | | | | | | | | | | | | |
Collapse
|
10
|
Ebersole G, Paranjape H, Anderson P, Powell H. Influence of hydration on fiber geometry in electrospun scaffolds. Acta Biomater 2012; 8:4342-8. [PMID: 22846591 DOI: 10.1016/j.actbio.2012.07.028] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2012] [Revised: 07/19/2012] [Accepted: 07/19/2012] [Indexed: 10/28/2022]
Abstract
Finite element models of tissue engineering scaffolds are powerful tools to understand scaffold function, including how external mechanical signals deform the scaffold at the meso- and microscales. Fiber geometry is needed to inform finite element models of fiber-based tissue engineering scaffolds; however, the accuracy and utility of these models may be limited if they are informed by non-hydrated geometries. Scanning electron microscopy and confocal microscopy, coupled with Fourier analysis of the resulting images, were used to quantify how hydration alters fiber geometry in electrospun collagen and polycaprolactone (PCL) scaffolds. The results also quantify how image size affects fiber geometry. Hydration is demonstrated to increase fiber tortuosity, defined as the ratio of actual fiber length:end-to-end fiber length. For collagen scaffolds, hydration increased the mean tortuosity from 1.05 to 1.21, primarily from large ∼2- to 10-fold) increases in smaller (<40μm) wavelength amplitudes. For PCL fibers, the mean tortuosity increased from 1.01 to only 1.04, primarily from modest ∼2-fold) increases in larger (>100μm) wavelength amplitudes. The results demonstrate that mechanical simulations of electrospun scaffolds should be informed with hydrated scaffold geometries of at least 200μm scale, in order to capture geometrical effects associated with fiber straightening.
Collapse
|
11
|
Blackstone BN, Powell HM. Morphogenesis and Biomechanics of Engineered Skin Cultured Under Uniaxial Strain. Adv Wound Care (New Rochelle) 2012; 1:69-74. [PMID: 24527283 DOI: 10.1089/wound.2011.0345] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2011] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Split-thickness autograft is the standard wound treatment for full-thickness burns. In large burns, sparse availability of uninjured skin prevents rapid closure of the wound, resulting in increased scar tissue formation or mortality. Tissue-engineered skin (ES) offers promise when autografts are not available. THE PROBLEM ES, constructed from a polymeric scaffold and skin cells, has been shown to reduce donor site area required to permanently close wounds, mortality, and morbidity from scarring but cannot restore all skin functions. Current generations of ES are orders of magnitude weaker than normal human skin, leading to difficulty in surgical application, greater susceptibility to mechanical damage during fabrication and application, and less elasticity and strength once engrafted. BASIC/CLINICAL SCIENCE ADVANCES Previous studies to improve ES biomechanics focus on altering the scaffolding material, which resulted in modest improvements but often inhibited proper skin development. As the skin is naturally under static strain, adding these mechanical cues to the culture environment is hypothesized to improve ES biomechanics. ES was cultured under applied static strains ranging from 0% to 40% strain for a total of 10 days. Strain magnitudes of 10% and 20% strain resulted in significantly stronger ES than unstrained controls, showed upregulation of many genes encoding structural extracellular matrix proteins, and exhibited increased epidermal cell proliferation and differentiation. CLINICAL CARE RELEVANCE Enhanced biomechanical properties of ES can allow for facile surgical application and less damage during dressing changes. CONCLUSION These findings suggest that mechanical cues play a significant role in skin development and should be further explored.
Collapse
Affiliation(s)
| | - Heather M. Powell
- Department of Materials Science and Engineering, The Ohio State University, Columbus, Ohio
| |
Collapse
|