1
|
Li D, Wang J, Zeng W, Zeng X, Liu Z, Cao H, Yuan D, Zheng T. The loss of helical flow in the thoracic aorta might be an identifying marker for the risk of acute type B aortic dissection. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 230:107331. [PMID: 36621070 DOI: 10.1016/j.cmpb.2022.107331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 12/06/2022] [Accepted: 12/29/2022] [Indexed: 06/17/2023]
Abstract
BACKGROUND AND OBJECTIVE The occurrence of acute type B aortic dissection (TBAD) remained unclear. This study aimed to investigate the association between flow features and hemodynamic parameters in aortas that demonstrated the risk of TBAD occurrence. METHODS The geometries of 15 hyperacute TBAD and 12 control patients (with healthy aorta) were reconstructed from computed tomography angiography images. Pre-TBAD models were then obtained by eliminating the dissection flaps. Flow features and hemodynamic parameters, including wall shear stress-related parameters and helicities, were compared between pre-TBAD and control models using computational fluid dynamics. RESULTS There were no significant differences in baseline characteristics and anatomical parameters between the two groups. Significant contralateral helical blood flow was present in the healthy thoracic aorta, while almost no helical flow was observed in the pre-TBAD group. In addition, the mean normal transverse wall shear stress (NtransWSS) was significantly higher in the pre-TBAD group (aortic arch 0.49±0.09 vs. 0.40±0.05, P = 0.04; descending aorta: 0.46±0.05 vs. 0.33±0.02, P<0.01). Moreover, a significantly negative correlation was found between helicity and NtransWSS in the descending aorta. Moreover, the location of primary tears in 12 pre-TABD subjects matched well with regions of high NtransWSS. CONCLUSIONS Loss of helical flow in the aortic arch and descending aorta may be a major flow feature in patients with underlying TBAD, resulting in increased flow disturbance and wall lesions.
Collapse
Affiliation(s)
- Da Li
- Department of Applied Mechanics, Sichuan University, No.24 South Section 1, Chengdu 610065, China; Yibin Institute of Industrial Technology, Sichuan University Yibin Park, Yibin, China
| | - Jiarong Wang
- Division of Vascular Surgery, Department of General Surgery, West China Hospital, Sichuan University, No. 37 Guo Xue Xiang, Chengdu 610041, China
| | - Wen Zeng
- Division of radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Xiangguo Zeng
- Department of Applied Mechanics, Sichuan University, No.24 South Section 1, Chengdu 610065, China
| | - Zhan Liu
- Department of Applied Mechanics, Sichuan University, No.24 South Section 1, Chengdu 610065, China; Yibin Institute of Industrial Technology, Sichuan University Yibin Park, Yibin, China
| | - Haoyao Cao
- Department of Applied Mechanics, Sichuan University, No.24 South Section 1, Chengdu 610065, China; Yibin Institute of Industrial Technology, Sichuan University Yibin Park, Yibin, China
| | - Ding Yuan
- Division of Vascular Surgery, Department of General Surgery, West China Hospital, Sichuan University, No. 37 Guo Xue Xiang, Chengdu 610041, China; Med-X center for informatics, Sichuan University, Chengdu, China.
| | - Tinghui Zheng
- Department of Applied Mechanics, Sichuan University, No.24 South Section 1, Chengdu 610065, China; Yibin Institute of Industrial Technology, Sichuan University Yibin Park, Yibin, China; Med-X center for informatics, Sichuan University, Chengdu, China.
| |
Collapse
|
2
|
Evaluation and Prediction of Mass Transport Properties for Porous Implant with Different Unit Cells: A Numerical Study. BIOMED RESEARCH INTERNATIONAL 2019; 2019:3610785. [PMID: 31179318 PMCID: PMC6507231 DOI: 10.1155/2019/3610785] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Accepted: 04/11/2019] [Indexed: 01/01/2023]
Abstract
Efficient exchange of nutrients and wastes required for cell proliferation and differentiation plays a pivotal role in improving the service life of porous implants. In this study, mass transport properties for porous implant with different unit cells were evaluated and predicted when the porosities are kept the same. To this end, three typical unit cells (diamond (DO), rhombic dodecahedron (RD), and octet truss (OT)) were selected, in which DO displayed diagonal-symmetrical shape, while RD and OT share midline-symmetrical structure. Then, single unit cells were designed quantitatively, and its shape parameters were measured and calculated. Moreover, corresponding porous scaffolds with same outline size were created, respectively. Furthermore, using computational fluid dynamics (CFD) methodology, flow performances with Dulbecco's Modified Eagle's Medium (DMEM) in vitro were simulated for three different porous implants, and flow trajectory, velocity, and wall shear stress which could reflect the properties of mass transfer and tissue regeneration were compared and predicted numerically. Results demonstrated that different unit cell could directly lead to different mass transport properties for porous implant, in spite of same porosity, scaffold size, and service environment. Additionally, by the results, DO displayed greater tortuosity, more appropriate areas, and smoother shear stress distribution than RD and OT, which would provide better surroundings for implant fixation and tissue regeneration. However, RD and OT showed better mass transport properties because of bigger maximum velocity (5.177 mm/s, 4.381 mm/s) than DO (3.941 mm/s). This study would provide great helps for unit cell selection and biological performance optimization for 3D printed bone implants.
Collapse
|
3
|
Li X, Liu X, Zhang P, Feng C, Sun A, Kang H, Deng X, Fan Y. Numerical simulation of haemodynamics and low-density lipoprotein transport in the rabbit aorta and their correlation with atherosclerotic plaque thickness. J R Soc Interface 2017; 14:rsif.2017.0140. [PMID: 28424305 DOI: 10.1098/rsif.2017.0140] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2017] [Accepted: 03/20/2017] [Indexed: 12/25/2022] Open
Abstract
Two mechanisms of shear stress and mass transport have been recognized to play an important role in the development of localized atherosclerosis. However, their relationship and roles in atherogenesis are still obscure. It is necessary to investigate quantitatively the correlation among low-density lipoproteins (LDL) transport, haemodynamic parameters and plaque thickness. We simulated blood flow and LDL transport in rabbit aorta using computational fluid dynamics and evaluated plaque thickness in the aorta of a high-fat-diet rabbit. The numerical results show that regions with high luminal LDL concentration tend to have severely negative haemodynamic environments (HEs). However, for regions with moderately and slightly high luminal LDL concentration, the relationship between LDL concentration and the above haemodynamic indicators is not clear cut. Point-by-point correlation with experimental results indicates that severe atherosclerotic plaque corresponds to high LDL concentration and seriously negative HEs, less severe atherosclerotic plaque is related to either moderately high LDL concentration or moderately negative HEs, and there is almost no atherosclerotic plaque in regions with both low LDL concentration and positive HEs. In conclusion, LDL distribution is closely linked to blood flow transport, and the synergetic effects of luminal surface LDL concentration and wall shear stress-based haemodynamic indicators may determine plaque thickness.
Collapse
Affiliation(s)
- Xiaoyin Li
- Key Laboratory for Biomechanics and Mechanobiology of the Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, People's Republic of China
| | - Xiao Liu
- Key Laboratory for Biomechanics and Mechanobiology of the Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, People's Republic of China
| | - Peng Zhang
- Key Laboratory for Biomechanics and Mechanobiology of the Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, People's Republic of China
| | - Chenglong Feng
- Key Laboratory for Biomechanics and Mechanobiology of the Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, People's Republic of China
| | - Anqiang Sun
- Key Laboratory for Biomechanics and Mechanobiology of the Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, People's Republic of China
| | - Hongyan Kang
- Key Laboratory for Biomechanics and Mechanobiology of the Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, People's Republic of China
| | - Xiaoyan Deng
- Key Laboratory for Biomechanics and Mechanobiology of the Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, People's Republic of China
| | - Yubo Fan
- Key Laboratory for Biomechanics and Mechanobiology of the Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, People's Republic of China .,National Research Center for Rehabilitation Technical Aids, Beijing, People's Republic of China
| |
Collapse
|
4
|
Bioinspired helical graft with taper to enhance helical flow. J Biomech 2016; 49:3643-3650. [DOI: 10.1016/j.jbiomech.2016.09.028] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2016] [Revised: 09/09/2016] [Accepted: 09/19/2016] [Indexed: 11/23/2022]
|
5
|
Spiral Laminar Flow: a Survey of a Three-Dimensional Arterial Flow Pattern in a Group of Volunteers. Eur J Vasc Endovasc Surg 2016; 52:674-680. [DOI: 10.1016/j.ejvs.2016.07.018] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2015] [Accepted: 07/16/2016] [Indexed: 11/18/2022]
|
6
|
Ha H, Kim GB, Kweon J, Lee SJ, Kim YH, Kim N, Yang DH. The influence of the aortic valve angle on the hemodynamic features of the thoracic aorta. Sci Rep 2016; 6:32316. [PMID: 27561388 PMCID: PMC4999809 DOI: 10.1038/srep32316] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2016] [Accepted: 08/02/2016] [Indexed: 11/17/2022] Open
Abstract
Since the first observation of a helical flow pattern in aortic blood flow, the existence of helical blood flow has been found to be associated with various pathological conditions such as bicuspid aortic valve, aortic stenosis, and aortic dilatation. However, an understanding of the development of helical blood flow and its clinical implications are still lacking. In our present study, we hypothesized that the direction and angle of aortic inflow can influence helical flow patterns and related hemodynamic features in the thoracic aorta. Therefore, we investigated the hemodynamic features in the thoracic aorta and various aortic inflow angles using patient-specific vascular phantoms that were generated using a 3D printer and time-resolved, 3D, phase-contrast magnetic resonance imaging (PC-MRI). The results show that the rotational direction and strength of helical blood flow in the thoracic aorta largely vary according to the inflow direction of the aorta, and a higher helical velocity results in higher wall shear stress distributions. In addition, right-handed rotational flow conditions with higher rotational velocities imply a larger total kinetic energy than left-handed rotational flow conditions with lower rotational velocities.
Collapse
Affiliation(s)
- Hojin Ha
- POSTECH Biotech Center, Pohang University of Science and Technology, San 31, Hyoja-dong, Pohang 790-784, South Korea
| | - Guk Bae Kim
- Asan Institute of Life Science, Asan Medical Center, University of Ulsan College of Medicine, 388-1 Poongnap-dong, Songpa-gu, Seoul 138-736, South Korea
| | - Jihoon Kweon
- Department of Cardiology, University of Ulsan College of Medicine, Asan Medical Center, 388-1 Poongnap-dong, Songpa-gu, Seoul 138-736, South Korea
| | - Sang Joon Lee
- POSTECH Biotech Center, Pohang University of Science and Technology, San 31, Hyoja-dong, Pohang 790-784, South Korea
- Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), San 31, Hyoja-dong, Pohang 790-784, South Korea
| | - Young-Hak Kim
- Department of Cardiology, University of Ulsan College of Medicine, Asan Medical Center, 388-1 Poongnap-dong, Songpa-gu, Seoul 138-736, South Korea
| | - Namkug Kim
- Department of Convergence Medicine, University of Ulsan College of Medicine, Asan Medical Center, 388-1 Poongnap-dong, Songpa-gu, Seoul 138-736, South Korea
- Department of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 388-1 Poongnap-dong, Songpa-gu, Seoul 138-736, South Korea
| | - Dong Hyun Yang
- Department of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 388-1 Poongnap-dong, Songpa-gu, Seoul 138-736, South Korea
| |
Collapse
|
7
|
Physiological Significance of Helical Flow in the Arterial System and its Potential Clinical Applications. Ann Biomed Eng 2014; 43:3-15. [DOI: 10.1007/s10439-014-1097-2] [Citation(s) in RCA: 93] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2014] [Accepted: 08/16/2014] [Indexed: 01/12/2023]
|