1
|
Dahaghin A, Salimibani M, Boszczyk A, Jóźwik A, Skrok M, Grasa J, Siedlecki D. Investigation of crystalline lens overshooting: ex vivo experiment and optomechanical simulation results. Front Bioeng Biotechnol 2024; 12:1348774. [PMID: 38655391 PMCID: PMC11035874 DOI: 10.3389/fbioe.2024.1348774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2023] [Accepted: 03/12/2024] [Indexed: 04/26/2024] Open
Abstract
Introduction: Crystalline lens overshooting refers to a situation in which the lens momentarily shifts too much from its typical location immediately after stopping the rotational movement of the eye globe. This movement can be observed using an optical technique called Purkinje imaging. Methods: In this work, an experimental setup was designed to reproduce this effect ex vivo using a fresh porcine eye. The sample was rotated 90° around its centroid using a high-velocity rotation stage, and the Purkinje image sequences were recorded, allowing us to quantify the overshooting effect. The numerical part of the study consisted of developing a computational model of the eye, based on the finite element method, that allowed us to understand the biomechanical behavior of the different tissues in this dynamic scenario. A 2D fluid-structure interaction model of the porcine eye globe, considering both the solid parts and humors, was created to reproduce the experimental outcomes. Results: Outputs of the simulation were analyzed using an optical simulation software package to assess whether the mechanical model behaves optically like the real ex vivo eye. The simulation predicted the experimental results by carefully adjusting the mechanical properties of the zonular fibers and the damping factor. Conclusion: This study effectively demonstrates the importance of characterizing the dynamic mechanical properties of the eye tissues to properly comprehend and predict the overshooting effect.
Collapse
Affiliation(s)
- Ali Dahaghin
- Department of Optics and Photonics, Wroclaw University of Science and Technology, Wrocław, Poland
| | - Milad Salimibani
- Department of Optics and Photonics, Wroclaw University of Science and Technology, Wrocław, Poland
| | - Agnieszka Boszczyk
- Department of Optics and Photonics, Wroclaw University of Science and Technology, Wrocław, Poland
| | - Agnieszka Jóźwik
- Department of Optics and Photonics, Wroclaw University of Science and Technology, Wrocław, Poland
| | - Marta Skrok
- Department of Optics and Photonics, Wroclaw University of Science and Technology, Wrocław, Poland
| | - Jorge Grasa
- Aragón Institute of Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza, Spain
| | - Damian Siedlecki
- Department of Optics and Photonics, Wroclaw University of Science and Technology, Wrocław, Poland
| |
Collapse
|
2
|
Pu Y, Liu Z, Ye L, Xia Y, Chen X, Wang K, Pierscionek BK. The major influence of anterior and equatorial zonular fibres on the far-to-near accommodation revealed by a 3D pre-stressed model of the anterior eye. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 242:107815. [PMID: 37729794 DOI: 10.1016/j.cmpb.2023.107815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 09/09/2023] [Accepted: 09/14/2023] [Indexed: 09/22/2023]
Abstract
PURPOSE To explore the synergistic function of the ligaments in eye, the zonular fibres, that mediate change in eye lens shape to allow for focussing over different distances. METHODS A set of 3D Finite Element models of the anterior eye together with a custom developed pre-stress modelling approach was proposed to simulate vision for distant objects (the unaccommodated state) to vision for near objects (accommodation). One of the five zonular groups was cut off in sequence creating five models with different zonular arrangements, the contribution of each zonular group was analysed by comparing results of each specific zonular-cut model with those from the all-zonules model in terms of lens shape and zonular tensions. RESULTS In the all-zonular model, the anterior and equatorial zonules carry the highest tensions. In the anterior zonular-cut model, the equatorial zonular tension increases while the posterior zonular tension decreases, resulting in an increase in the change in Central Optical Power (COP). In the equatorial zonular-cut model, both the anterior and posterior zonular tensions increase, causing a decreasing change in COP. The change in COP decreases only slightly in the other models. For vitreous zonular-cut models, little change was seen in either the zonular tension or the change in COP. CONCLUSIONS The anterior and the equatorial zonular fibres have the major influence on the change in lens optical power, with the anterior zonules having a negative effect and the equatorial zonules contributing a positive effect. The contribution to variations in optical power by the equatorial zonules is much larger than by the posterior zonules.
Collapse
Affiliation(s)
- Yutian Pu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry for Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Engineering Medicine and School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Ziyuan Liu
- Department of Ophthalmology, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing, China
| | - Lin Ye
- Faculty of Health, Education, Medicine and Social Care, Medical Technology Research Centre, Anglia Ruskin University, Bishops Hall Lane, Chelmsford, United Kingdom
| | - Yunxin Xia
- Key Laboratory for Biomechanics and Mechanobiology of Ministry for Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Engineering Medicine and School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Xiaoyong Chen
- Department of Ophthalmology, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing, China
| | - Kehao Wang
- Key Laboratory for Biomechanics and Mechanobiology of Ministry for Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Engineering Medicine and School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
| | - Barbara K Pierscionek
- Faculty of Health, Education, Medicine and Social Care, Medical Technology Research Centre, Anglia Ruskin University, Bishops Hall Lane, Chelmsford, United Kingdom
| |
Collapse
|
3
|
Shi Y, Jones W, Beatty W, Tan Q, Mecham RP, Kumra H, Reinhardt DP, Gibson MA, Reilly MA, Rodriguez J, Bassnett S. Latent-transforming growth factor beta-binding protein-2 (LTBP-2) is required for longevity but not for development of zonular fibers. Matrix Biol 2020; 95:15-31. [PMID: 33039488 DOI: 10.1016/j.matbio.2020.10.002] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 10/04/2020] [Accepted: 10/04/2020] [Indexed: 01/06/2023]
Abstract
Latent-transforming growth factor beta-binding protein 2 (LTBP-2) is a major component of arterial and lung tissue and of the ciliary zonule, the system of extracellular fibers that centers and suspends the lens in the eye. LTBP-2 has been implicated previously in the development of extracellular microfibrils, although its exact role remains unclear. Here, we analyzed the three-dimensional structure of the ciliary zonule in wild type mice and used a knockout model to test the contribution of LTBP-2 to zonule structure and mechanical properties. In wild types, zonular fibers had diameters of 0.5-1.0 micrometers, with an outer layer of fibrillin-1-rich microfibrils and a core of fibrillin-2-rich microfibrils. LTBP-2 was present in both layers. The absence of LTBP-2 did not affect the number of fibers, their diameters, nor their coaxial organization. However, by two months of age, LTBP-2-depleted fibers began to rupture, and by six months, a fully penetrant ectopia lentis phenotype was present, as confirmed by in vivo imaging. To determine whether the seemingly normal fibers of young mice were compromised mechanically, we compared zonule stress/strain relationships of wild type and LTBP-2-deficient mice and developed a quasi-linear viscoelastic engineering model to analyze the resulting data. In the absence of LTBP-2, the ultimate tensile strength of the zonule was reduced by about 50%, and the viscoelastic behavior of the fibers was altered significantly. We developed a harmonic oscillator model to calculate the forces generated during saccadic eye movement. Model simulations suggested that mutant fibers are prone to failure during rapid rotation of the eyeball. Together, these data indicate that LTBP-2 is necessary for the strength and longevity of zonular fibers, but not necessarily for their formation.
Collapse
Affiliation(s)
- Y Shi
- Department of Ophthalmology & Visual Sciences, Washington University School of Medicine, 660 S. Euclid Ave, Box 8096, St. Louis, MO 63110, USA
| | - W Jones
- Department of Ophthalmology & Visual Sciences, Washington University School of Medicine, 660 S. Euclid Ave, Box 8096, St. Louis, MO 63110, USA
| | - W Beatty
- Department of Molecular Microbiology, Washington University, St. Louis, MO, USA
| | - Q Tan
- Department of Ophthalmology & Visual Sciences, Washington University School of Medicine, 660 S. Euclid Ave, Box 8096, St. Louis, MO 63110, USA
| | - R P Mecham
- Department of Cell Biology & Physiology, Washington University, St. Louis, MO, USA
| | - H Kumra
- Department of Anatomy & Cell Biology, and Faculty of Dentistry, McGill University, Montreal, Quebec, Canada
| | - D P Reinhardt
- Department of Anatomy & Cell Biology, and Faculty of Dentistry, McGill University, Montreal, Quebec, Canada
| | - M A Gibson
- Department of Medical Sciences, Adelaide Medical School, University of Adelaide, Adelaide, Australia
| | - M A Reilly
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA; Department of Ophthalmology and Visual Science, The Ohio State University, Columbus, OH, USA
| | - J Rodriguez
- Department of Basic Sciences, St. Louis College of Pharmacy, St. Louis, MO, USA
| | - S Bassnett
- Department of Ophthalmology & Visual Sciences, Washington University School of Medicine, 660 S. Euclid Ave, Box 8096, St. Louis, MO 63110, USA; Department of Cell Biology & Physiology, Washington University, St. Louis, MO, USA.
| |
Collapse
|
4
|
Abstract
The Zonule of Zinn, or ciliary zonule, is the elaborate system of extracellular fibers that centers the lens in the eye. In humans, the fibers transmit forces that flatten the lens during the process of disaccommodation, thereby bringing distant objects into focus. Zonular fibers are composed almost entirely of 10-12 nm-wide microfibrils, of which polymerized fibrillin is the most abundant component. The thickest fibers have a fascicular organization, where hundreds or thousands of microfibrils are gathered into micrometer-wide bundles. Many such bundles are aggregated to form a fiber. Dozens of proteins comprise the zonule. Most are derived from cells of the non-pigmented ciliary epithelium in the pars plana region, although some are probably contributed by the lens and perhaps other tissues of the anterior segment. Zonular fibers are viscoelastic cables but their component microfibrils are rather stiff structures. Thus, the elastic properties of the fibers likely stem from lateral interactions between microfibrils. Rupture of zonular fibers and subsequent lens dislocation (ectopia lentis) can result from blunt force trauma or be a sequela of other eye diseases, notably exfoliation syndrome. Ectopia lentis is also a feature of syndromic conditions caused typically by mutations in microfibril-associated genes. The resulting ocular phenotypes raise the possibility that the zonule regulates lens size and shape, globe size, and even corneal topology, in addition to its well-recognized role in accommodation.
Collapse
Affiliation(s)
- Steven Bassnett
- Department of Ophthalmology & Visual Sciences, Washington University School of Medicine, 660 South Euclid Avenue, Campus Box 8096, St. Louis, MO 63110, USA.
| |
Collapse
|
5
|
Sándor GL, Kiss Z, Bocskai ZI, Tóth G, Temesi T, Nagy ZZ. Evaluation of mechanical resistance to tearing of the anterior lens capsule after staining with different concentrations of trypan blue. J Cataract Refract Surg 2020; 46:293-297. [PMID: 32126044 DOI: 10.1097/j.jcrs.0000000000000017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate and compare the mechanical resistance to tearing of the anterior lens capsule opening after staining with different concentrations of trypan blue in ex vivo porcine eyes. SETTING Semmelweis University, and Budapest University of Technology and Economics, Budapest, Hungary. DESIGN Experimental study. METHODS The study comprised 75 porcine eyes. The capsule was unstained in the Control Group (n = 25 eyes), 0.06% trypan blue was used to stain the capsule in Stained 1 Group (n = 25 eyes), and 0.1% trypan blue was used to stain the capsule in Stained 2 Group (n = 25 eyes). After capsulorhexis, the capsule openings were stretched with custom-designed testing equipment until they ruptured. The rupture force (RF), circumference stretching ratio (CSR), and secant modulus at 10 mN (SM10mN) and 50 mN (SM50mN) were evaluated. RESULTS In total, 75 eyes were enrolled. There were no statistically significant differences in the RF (P = .8924) or CSR (P = .3876) among the groups. There were no statistically significant differences in the SM10mN (P = .8215) or SM50mN (P = .4184) among the groups. CONCLUSIONS In this porcine eye model, the trypan blue concentrations that are routinely used in cataract surgery had no effect on capsular rim stability.
Collapse
Affiliation(s)
- Gábor L Sándor
- Department of Ophthalmology (Sándor, Tóth, Nagy), Semmelweis University, Budapest, and Department of Polymer Engineering (Kiss, Temesi), Biomechanical Research Centre (Kiss), Department of Structural Mechanics (Bocskai), Budapest University of Technology and Economics, Hungary
| | | | | | | | | | | |
Collapse
|
6
|
Bassnett S. A method for preserving and visualizing the three-dimensional structure of the mouse zonule. Exp Eye Res 2019; 185:107685. [PMID: 31158380 DOI: 10.1016/j.exer.2019.05.025] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2019] [Revised: 05/29/2019] [Accepted: 05/30/2019] [Indexed: 01/18/2023]
Abstract
Mechanical failure of the ciliary zonule characterizes several ocular and systemic diseases. The mouse has emerged as a useful model system to investigate the composition and structure/function relationships of the zonule. However, visualizing the organization of the diaphanous fibers that comprise the zonule is technically challenging because the fibers do not take up conventional histological stains and are disrupted easily during processing. Here, we describe a simple method for maintaining physiological pressure within the mouse eye during fixation, and a gel-embedding technique for stabilizing the zonular fibers during subsequent tissue processing and imaging steps. This approach facilitates quantitative measurements of fiber number and cross-sectional dimensions and will allow the effects of targeted disruption of zonule components to be assessed systematically.
Collapse
Affiliation(s)
- Steven Bassnett
- Ophthalmology and Visual Sciences, Washington University School of Medicine, United States.
| |
Collapse
|
7
|
Jones W, Rodriguez J, Bassnett S. Targeted deletion of fibrillin-1 in the mouse eye results in ectopia lentis and other ocular phenotypes associated with Marfan syndrome. Dis Model Mech 2019; 12:dmm.037283. [PMID: 30642872 PMCID: PMC6361150 DOI: 10.1242/dmm.037283] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Accepted: 12/11/2018] [Indexed: 01/09/2023] Open
Abstract
Fibrillin is an evolutionarily ancient protein that lends elasticity and resiliency to a variety of tissues. In humans, mutations in fibrillin-1 cause Marfan and related syndromes, conditions in which the eye is often severely affected. To gain insights into the ocular sequelae of Marfan syndrome, we targeted Fbn1 in mouse lens or non-pigmented ciliary epithelium (NPCE). Conditional knockout of Fbn1 in NPCE, but not lens, profoundly affected the ciliary zonule, the system of fibrillin-rich fibers that centers the lens in the eye. The tensile strength of the fibrillin-depleted zonule was reduced substantially, due to a shift toward production of smaller caliber fibers. By 3 months, zonular fibers invariably ruptured and mice developed ectopia lentis, a hallmark of Marfan syndrome. At later stages, untethered lenses lost their polarity and developed cataracts, and the length and volume of mutant eyes increased. This model thus captures key aspects of Marfan-related syndromes, providing insights into the role of fibrillin-1 in eye development and disease. Summary: Targeted knockout of Fbn1 in the ciliary epithelium of the mouse eye undermines the structural and biomechanical integrity of the ciliary zonule and results in an ectopia lentis phenotype.
Collapse
Affiliation(s)
- Wendell Jones
- Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, 660 S. Euclid Ave, Box 8096, St. Louis, MO 63117, USA
| | - Juan Rodriguez
- St Louis College of Pharmacy, Department of Basic Sciences, 4588 Parkview Place, St. Louis, MO 63110, USA
| | - Steven Bassnett
- Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, 660 S. Euclid Ave, Box 8096, St. Louis, MO 63117, USA
| |
Collapse
|
8
|
Shirzadi H, Zohoor H, Naserkhaki S. Biomechanical simulation of eye-airbag impacts during vehicle accidents. Proc Inst Mech Eng H 2018; 232:699-707. [PMID: 29888654 DOI: 10.1177/0954411918778063] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Airbags are safety devices in vehicles effectively suppressing passengers' injuries during accidents. Although there are still many cases of eye injuries reported due to eye-airbag impacts in recent years. Biomechanical approaches are now feasible and can considerably help experts to investigate the issue without ethical concerns. The eye-airbag impact-induced stresses/strains in various components of the eye were found to investigate the risk of injury in different conditions (impact velocity and airbag pressure). Three-dimensional geometry of the eyeball, fat and bony socket as well as the airbag were developed and meshed to develop a finite element model. Nonlinear material properties of the vitreous body and sclera were found through the in vitro tests on ovine samples and for the other components were taken from the literature. The eye collided the airbag due to the velocity field in the dynamic explicit step in Abaqus. Results of compression tests showed a nonlinear curve for vitreous body with average ultimate stress of 22 (18-25) kPa. Tensile behavior of sclera was viscoelastic nonlinear with ultimate stresses changing from 2.51 (2.3-2.7) to 4.3 (4-4.6) MPa when loading strain rate increased from 10 to 600 mm/min. Sclera, ciliary body, cornea and lens were the eye components with highest stresses (maximum stress reached up to 9.3 MPa). Cornea, retina and choroid experienced the highest strains with the maximum up to 14.1%. According to the previously reported injury criteria for cornea, it was at high risk of injury considering both stress and strains. Reduced pressure of the airbag was beneficial decreased stress of all components. Comprehensive investigations in this area can disclose biomechanical behavior of the eye during eye-airbag impact. Effective guidelines can be drawn for airbag design for instance the airbag pressure which reduces risk of eye injury.
Collapse
Affiliation(s)
- Hooman Shirzadi
- 1 Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - Hassan Zohoor
- 2 Center of Excellence in Design, Robotics and Automation, Sharif University of Technology, Academician, Academy of Sciences of IR Iran
| | - Sadegh Naserkhaki
- 3 Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
| |
Collapse
|