1
|
Wechsler I, Wolf A, Shanbhag J, Leyendecker S, Eskofier BM, Koelewijn AD, Wartzack S, Miehling J. Bridging the sim2real gap. Investigating deviations between experimental motion measurements and musculoskeletal simulation results-a systematic review. Front Bioeng Biotechnol 2024; 12:1386874. [PMID: 38919383 PMCID: PMC11196827 DOI: 10.3389/fbioe.2024.1386874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Accepted: 05/21/2024] [Indexed: 06/27/2024] Open
Abstract
Musculoskeletal simulations can be used to estimate biomechanical variables like muscle forces and joint torques from non-invasive experimental data using inverse and forward methods. Inverse kinematics followed by inverse dynamics (ID) uses body motion and external force measurements to compute joint movements and the corresponding joint loads, respectively. ID leads to residual forces and torques (residuals) that are not physically realistic, because of measurement noise and modeling assumptions. Forward dynamic simulations (FD) are found by tracking experimental data. They do not generate residuals but will move away from experimental data to achieve this. Therefore, there is a gap between reality (the experimental measurements) and simulations in both approaches, the sim2real gap. To answer (patho-) physiological research questions, simulation results have to be accurate and reliable; the sim2real gap needs to be handled. Therefore, we reviewed methods to handle the sim2real gap in such musculoskeletal simulations. The review identifies, classifies and analyses existing methods that bridge the sim2real gap, including their strengths and limitations. Using a systematic approach, we conducted an electronic search in the databases Scopus, PubMed and Web of Science. We selected and included 85 relevant papers that were sorted into eight different solution clusters based on three aspects: how the sim2real gap is handled, the mathematical method used, and the parameters/variables of the simulations which were adjusted. Each cluster has a distinctive way of handling the sim2real gap with accompanying strengths and limitations. Ultimately, the method choice largely depends on various factors: available model, input parameters/variables, investigated movement and of course the underlying research aim. Researchers should be aware that the sim2real gap remains for both ID and FD approaches. However, we conclude that multimodal approaches tracking kinematic and dynamic measurements may be one possible solution to handle the sim2real gap as methods tracking multimodal measurements (some combination of sensor position/orientation or EMG measurements), consistently lead to better tracking performances. Initial analyses show that motion analysis performance can be enhanced by using multimodal measurements as different sensor technologies can compensate each other's weaknesses.
Collapse
Affiliation(s)
- Iris Wechsler
- Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Alexander Wolf
- Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Julian Shanbhag
- Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Sigrid Leyendecker
- Institute of Applied Dynamics, Department of Mechanical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Bjoern M. Eskofier
- Machine Learning and Data Analytics Lab, Department Artificial Intelligence in Biomedical Engineering (AIBE), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Anne D. Koelewijn
- Machine Learning and Data Analytics Lab, Department Artificial Intelligence in Biomedical Engineering (AIBE), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
- Chair of Autonomous Systems and Mechatronics, Department of Electrical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Sandro Wartzack
- Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Jörg Miehling
- Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| |
Collapse
|
2
|
Nagaraja VH, Bergmann JHM, Andersen MS, Thompson MS. Comparison of a Scaled Cadaver-Based Musculoskeletal Model With a Clinical Upper Extremity Model. J Biomech Eng 2023; 145:1150107. [PMID: 36346198 DOI: 10.1115/1.4056172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2018] [Accepted: 11/01/2022] [Indexed: 11/11/2022]
Abstract
Reliably and accurately estimating joint/segmental kinematics from optical motion capture data has remained challenging. Studies objectively characterizing human movement patterns have typically involved inverse kinematics and inverse dynamics techniques. Subsequent research has included scaled cadaver-based musculoskeletal (MSK) modeling for noninvasively estimating joint and muscle loads. As one of the ways to enhance confidence in the validity of MSK model predictions, the kinematics from the preceding step that drives such a model needs to be checked for agreement or compared with established/widely used models. This study rigorously compares the upper extremity (UE) joint kinematics calculated by the Dutch Shoulder Model implemented in the AnyBody Managed Model Repository (involving multibody kinematics optimization (MKO)) with those estimated by the Vicon Plug-in Gait model (involving single-body kinematics optimization (SKO)). Ten subjects performed three trials of (different types of) reaching tasks in a three-dimensional marker-based optical motion capture laboratory setting. Joint angles, processed marker trajectories, and reconstruction residuals corresponding to both models were compared. Scatter plots and Bland-Altman plots were used to assess the agreement between the two model outputs. Results showed the largest differences between the two models for shoulder, followed by elbow and wrist, with all root-mean-squared differences less than 10 deg (although this limit might be unacceptable for clinical use). Strong-to-excellent Spearman's rank correlation coefficients were found between the two model outputs. The Bland-Altman plots showed a good agreement between most of the outputs. In conclusion, results indicate that these two models with different kinematic algorithms broadly agree with each other, albeit with few key differences.
Collapse
Affiliation(s)
- Vikranth H Nagaraja
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX1 3PJ, UK
| | - Jeroen H M Bergmann
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX1 3PJ, UK
| | - Michael S Andersen
- Department of Materials and Production, Aalborg University, Fibigerstraede 16, Aalborg East DK-9220, Denmark
| | - Mark S Thompson
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX1 3PJ, UK
| |
Collapse
|
3
|
Goubault E, Martinez R, Assila N, Monga-Dubreuil É, Dowling-Medley J, Dal Maso F, Begon M. Effect of Expertise on Shoulder and Upper Limb Kinematics, Electromyography, and Estimated Muscle Forces During a Lifting Task. HUMAN FACTORS 2022; 64:800-819. [PMID: 33236930 DOI: 10.1177/0018720820965021] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
OBJECTIVE To highlight the working strategies used by expert manual handlers compared with novice manual handlers, based on recordings of shoulder and upper limb kinematics, electromyography (EMG), and estimated muscle forces during a lifting task. BACKGROUND Novice workers involved in assembly, manual handling, and personal assistance tasks are at a higher risk of upper limb musculoskeletal disorders (MSDs). However, few studies have investigated the effect of expertise on upper limb exposure during workplace tasks. METHOD Sixteen experts in manual handling and sixteen novices were equipped with 10 electromyographic electrodes to record shoulder muscle activity during a manual handling task consisting of lifting a box (8 or 12 kg), instrumented with three six-axis force sensors, from hip to eye level. Three-dimensional trunk and upper limb kinematics, hand-to-box contact forces, and EMG were recorded. Then, joint contributions, activation levels, and muscle forces were calculated and compared between groups. RESULTS Sternoclavicular-acromioclavicular joint contributions were higher in experts at the beginning of the movement, and in novices at the end, whereas the opposite was observed for the glenohumeral joint. EMG activation levels were 37% higher for novices but predicted muscle forces were higher in experts. CONCLUSION This study highlights significant differences between experts and novices in shoulder kinematics, EMG, and muscle forces; hence, providing effective work guidelines to ensure the development of a safe handling strategy is important. APPLICATION Shoulder kinematics, EMG, and muscle forces could be used as ergonomic tools to identify inappropriate techniques that could increase the prevalence of shoulder injuries.
Collapse
Affiliation(s)
| | | | - Najoua Assila
- 5622 Université de Montréal, Montréal, QC, Canada
- Sainte-Justine Hospital Research Center, Montréal, QC, Canada
| | | | | | - Fabien Dal Maso
- 5622 Université de Montréal, Montréal, QC, Canada
- Centre Interdisciplinaire sur le Cerveau et l'Apprentissage, Montréal, QC, Canada
| | - Mickael Begon
- 5622 Université de Montréal, Montréal, QC, Canada
- Sainte-Justine Hospital Research Center, Montréal, QC, Canada
| |
Collapse
|
4
|
Dumas R, Duprey S. Subject-specific model-derived kinematics of the shoulder based on skin markers during arm abduction up to 180° - assessment of 4 gleno-humeral joint models. J Biomech 2022; 136:111061. [PMID: 35344828 DOI: 10.1016/j.jbiomech.2022.111061] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 02/01/2022] [Accepted: 03/21/2022] [Indexed: 11/29/2022]
Abstract
Accuracy of shoulder kinematics predicted by multi-body kinematics optimisation depend on the joint models used. This study assesses the influence of four different subject-specific gleno-humeral joint models within multi-body kinematics optimisation: a 6-degree-of-freedom joint (i.e. single-body kinematics optimisation), a sphere-on-sphere joint (with two spheres of different radii) and a spherical joint with or without penalised translation. To drive these models, the 3D coordinates of 12 skin markers of 6 subjects performing static arm abduction poses up to 180° were used. The reference data was obtained using biplane X-rays from which 3D bone reconstructions were generated: scapula and humerus were 3D reconstructed by fitting a template model made of geometrical primitives on the two bones' X-rays. Without any motion capture system, the recording of the skin markers was performed at the very same time than the X-rays with radiopaque markers. The gleno-humeral displacements and angles, and scapula-thoracic angles were computed. The gleno-humeral sphere-on-sphere joint provided slightly better results than the spherical joint with or without penalised translation, but considerably better gleno-humeral displacements than the 6-DoF joint. Considering that it can easily be personalised from medical images, this sphere-on-sphere model seems promising for shoulder multi-body kinematics optimisation.
Collapse
Affiliation(s)
- R Dumas
- Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR T_ 9406, F-69622 Lyon, France.
| | - S Duprey
- Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR T_ 9406, F-69622 Lyon, France.
| |
Collapse
|
5
|
Campeau-Lecours A, Vu DS, Schweitzer F, Roy JS. Alternative Representation of the Shoulder Orientation Based on the Tilt-and-Torsion Angles. J Biomech Eng 2020; 142:1074129. [PMID: 32005995 DOI: 10.1115/1.4046203] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Indexed: 11/08/2022]
Abstract
The International Society of Biomechanics (ISB) has proposed standardized recommendations for recording human joint motion. The Euler angles-the orientation representation currently proposed by the ISB-have two drawbacks, namely, the issue of singularities (gimbal lock) and the difficulty to obtain clinical and interpretable orientation representation for compound movements. The orientation representation of the shoulder joint with the Euler angles is particularly challenging due to its broad range of motion. This paper proposes and evaluates an alternative orientation representation for shoulder movement based on the tilt-and-torsion representation, a method that aims at providing a more clinically interpretable solution for describing joint movements compared to the standard Euler angles. Three studies were performed to compare the different orientation representation methods. The first two studies consist in simulations of arm elevation in different planes. The third study is an experiment using inertial-measurement-units with one test subject performing shoulder elevation movements in different planes. The tilt-and-torsion representation is then compared with different Euler angle conventions. The results show that Euler angles are biased or clinically uninterpretable for compound movements. Conversely, tilt-and-torsion representation does not suffer from these limitations. Although not extensive, the experiments suggest that the tilt-and-torsion representation has the potential to better represent human movements and provide more clinically interpretable results than the Euler angles.
Collapse
Affiliation(s)
- Alexandre Campeau-Lecours
- Department of Mechanical Engineering, Center for Interdisciplinary Research in Rehabilitation and Social Integration, Université Laval, Quebec, QC G1V 0A6, Canada
| | - Dinh-Son Vu
- College of Engineering and Technology, American University of Middle East, Eqaila 5482+W2, Kuwait
| | - Frédéric Schweitzer
- Department of Mechanical Engineering, Center for Interdisciplinary Research in Rehabilitation and Social Integration, Université Laval, Quebec, QC G1V 0A6, Canada
| | - Jean-Sébastien Roy
- Department of Rehabilitation, Center for Interdisciplinary Research in Rehabilitation and Social Integration, Université Laval, Quebec, QC G1V 0A6, Canada
| |
Collapse
|
6
|
Challis JH. Short Communication: Determining the average attitude of a rigid body. J Biomech 2020; 98:109492. [PMID: 31733819 DOI: 10.1016/j.jbiomech.2019.109492] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2019] [Revised: 09/27/2019] [Accepted: 11/04/2019] [Indexed: 10/25/2022]
Abstract
Three-dimensional angular kinematics exist on the surface of a unit hypersphere, therefore the average attitude cannot always be accurately computed by averaging Cardan angles. This study derives and evaluates a method for determining average body attitude, by exploiting the singular value decomposition of the average of a set of attitude matrices. To test the method 1000 criterion attitudes were determined, and for each attitude 10 noisy attitude matrices generated. The new method and the averaging of Cardan angles extracted from the 10 noisy attitude matrices were evaluated for their ability to estimate the criterion attitude. At low attitude variance the two approaches provided equivalent results, but with increasing attitude variance levels the new procedure was superior. The method provides superior estimates of average attitude compared with averaging Cardan angles, by accounting for the geometric distribution of rigid body attitudes on the surface of a unit hypersphere.
Collapse
Affiliation(s)
- John H Challis
- Biomechanics Laboratory, Pennsylvania State University, University Park, USA.
| |
Collapse
|
7
|
Begon M, Andersen MS, Dumas R. Multibody Kinematics Optimization for the Estimation of Upper and Lower Limb Human Joint Kinematics: A Systematized Methodological Review. J Biomech Eng 2019; 140:2666614. [PMID: 29238821 DOI: 10.1115/1.4038741] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Indexed: 11/08/2022]
Abstract
Multibody kinematics optimization (MKO) aims to reduce soft tissue artefact (STA) and is a key step in musculoskeletal modeling. The objective of this review was to identify the numerical methods, their validation and performance for the estimation of the human joint kinematics using MKO. Seventy-four papers were extracted from a systematized search in five databases and cross-referencing. Model-derived kinematics were obtained using either constrained optimization or Kalman filtering to minimize the difference between measured (i.e., by skin markers, electromagnetic or inertial sensors) and model-derived positions and/or orientations. While hinge, universal, and spherical joints prevail, advanced models (e.g., parallel and four-bar mechanisms, elastic joint) have been introduced, mainly for the knee and shoulder joints. Models and methods were evaluated using: (i) simulated data based, however, on oversimplified STA and joint models; (ii) reconstruction residual errors, ranging from 4 mm to 40 mm; (iii) sensitivity analyses which highlighted the effect (up to 36 deg and 12 mm) of model geometrical parameters, joint models, and computational methods; (iv) comparison with other approaches (i.e., single body kinematics optimization and nonoptimized kinematics); (v) repeatability studies that showed low intra- and inter-observer variability; and (vi) validation against ground-truth bone kinematics (with errors between 1 deg and 22 deg for tibiofemoral rotations and between 3 deg and 10 deg for glenohumeral rotations). Moreover, MKO was applied to various movements (e.g., walking, running, arm elevation). Additional validations, especially for the upper limb, should be undertaken and we recommend a more systematic approach for the evaluation of MKO. In addition, further model development, scaling, and personalization methods are required to better estimate the secondary degrees-of-freedom (DoF).
Collapse
Affiliation(s)
- Mickaël Begon
- Département de Kinésiologie, Université de Montréal, 1700 Jacques Tétreault, Laval, QC H7N 0B6, Canada.,Centre de Recherche du Centre Hospitalier, Universitaire Sainte-Justine, 3175 Chemin de la Côte-Sainte-Catherine, Montréal, QC H3T 1C5, Canada e-mail:
| | - Michael Skipper Andersen
- Department of Materials and Production, Aalborg University, Fibigerstrade 16, Aalborg East DK-9220, Denmark e-mail:
| | - Raphaël Dumas
- Univ Lyon, Université Claude Bernard Lyon 1, IFSTTAR, LBMC UMR_T9406, Lyon F69622, France e-mail:
| |
Collapse
|
8
|
Hybois S, Puchaud P, Bourgain M, Lombart A, Bascou J, Lavaste F, Fodé P, Pillet H, Sauret C. Comparison of shoulder kinematic chain models and their influence on kinematics and kinetics in the study of manual wheelchair propulsion. Med Eng Phys 2019; 69:153-160. [PMID: 31221514 DOI: 10.1016/j.medengphy.2019.06.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2018] [Revised: 04/03/2019] [Accepted: 06/06/2019] [Indexed: 11/30/2022]
Abstract
Several kinematic chains of the upper limbs have been designed in musculoskeletal models to investigate various upper extremity activities, including manual wheelchair propulsion. The aim of our study was to compare the effect of an ellipsoid mobilizer formulation to describe the motion of the scapulothoracic joint with respect to regression-based models on shoulder kinematics, shoulder kinetics and computational time, during manual wheelchair propulsion activities. Ten subjects, familiar with manual wheelchair propulsion, were equipped with reflective markers and performed start-up and propulsion cycles with an instrumented field wheelchair. Kinematic data obtained from the optoelectronic system and kinetic data measured by the sensors on the wheelchair were processed using the OpenSim software with three shoulder joint modeling versions (ellipsoid mobilizer, regression equations or fixed scapula) of an upper-limb musculoskeletal model. As expected, the results obtained with the three versions of the model varied, for both segment kinematics and shoulder kinetics. With respect to the model based on regression equations, the model describing the scapulothoracic joint as an ellipsoid could capture the kinematics of the upper limbs with higher fidelity. In addition, the mobilizer formulation allowed to compute consistent shoulder moments at a low computer processing cost. Further developments should be made to allow a subject-specific definition of the kinematic chain.
Collapse
Affiliation(s)
- Samuel Hybois
- Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, Paris, France.
| | - Pierre Puchaud
- Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, Paris, France; Centre d'Études et de Recherche sur l'Appareillage des Handicapés, Institution Nationale des Invalides, Créteil, France
| | - Maxime Bourgain
- Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, Paris, France
| | - Antoine Lombart
- Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, Paris, France; Centre d'Études et de Recherche sur l'Appareillage des Handicapés, Institution Nationale des Invalides, Créteil, France
| | - Joseph Bascou
- Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, Paris, France; Centre d'Études et de Recherche sur l'Appareillage des Handicapés, Institution Nationale des Invalides, Créteil, France
| | - François Lavaste
- Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, Paris, France; Centre d'Études et de Recherche sur l'Appareillage des Handicapés, Institution Nationale des Invalides, Créteil, France
| | - Pascale Fodé
- Centre d'Études et de Recherche sur l'Appareillage des Handicapés, Institution Nationale des Invalides, Créteil, France
| | - Hélène Pillet
- Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, Paris, France
| | - Christophe Sauret
- Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, Paris, France
| |
Collapse
|
9
|
Slater AA, Hullfish TJ, Baxter JR. The impact of thigh and shank marker quantity on lower extremity kinematics using a constrained model. BMC Musculoskelet Disord 2018; 19:399. [PMID: 30424811 PMCID: PMC6234533 DOI: 10.1186/s12891-018-2329-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Accepted: 10/29/2018] [Indexed: 12/20/2022] Open
Abstract
Background Musculoskeletal models are commonly used to quantify joint motions and loads during human motion. Constraining joint kinematics simplifies these models but the implications of the placement and quantity of markers used during data acquisition remains unclear. The purpose of this study was to establish the effects of marker placement and quantity on lower extremity kinematics calculated using a constrained-kinematic model. We hypothesized that a constrained-kinematic model would produce lower-extremity kinematics errors that correlated with the number of tracking markers removed from the thigh and shank. Methods Healthy-young adults (N = 10) walked on a treadmill at slow, moderate, and fast speeds while skin-mounted markers were tracked using motion capture. Lower extremity kinematics were calculated for 256 combinations of leg and shank markers to establish the implications of marker placement and quantity on joint kinematics. Marker combinations that yielded differences greater than 5 degrees were tested with paired t-tests and the relationship between number of markers and kinematic errors were modeled with polynomials to determine goodness of fit (R2). Results Sagittal joint and hip coronal kinematics errors were smaller than documented errors caused by soft-tissue artifact, which tends to be approximately 5 degrees, when excluding thigh and shank markers. Joint angle and center kinematic errors negatively correlated with the number of markers included in the analyses (R2 > 0.97) and typically showed the greatest error reductions when two markers were included on the thigh or shank segments. Further, we demonstrated that a simplified marker set that included markers on the pelvis, lateral knee condyle, lateral malleolus, and shoes produced kinematics that strongly agreed with the traditional marker set that included 3 tracking markers for each segment. Conclusion Constrained-kinematic models are resilient to marker placement and quantity, which has implications on study design and post-processing workflows.
Collapse
Affiliation(s)
- Annelise A Slater
- Human Motion Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, 3737 Market Street, Suite 702, Philadelphia, PA, 19104, USA
| | - Todd J Hullfish
- Human Motion Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, 3737 Market Street, Suite 702, Philadelphia, PA, 19104, USA
| | - Josh R Baxter
- Human Motion Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, 3737 Market Street, Suite 702, Philadelphia, PA, 19104, USA.
| |
Collapse
|
10
|
Affiliation(s)
- Valentina Camomilla
- Department of Movement, Human and Health Sciences, Università degli Studi di Roma ''Foro Italico'', Rome, Italy; Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System, Università degli Studi di Roma "Foro Italico", Rome, Italy.
| | - Raphaël Dumas
- Univ Lyon, Université Claude Bernard Lyon 1, IFSTTAR, LBMC UMR_T9406, F69622 Lyon, France; Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System, Università degli Studi di Roma "Foro Italico", Rome, Italy
| | - Aurelio Cappozzo
- Department of Movement, Human and Health Sciences, Università degli Studi di Roma ''Foro Italico'', Rome, Italy; Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System, Università degli Studi di Roma "Foro Italico", Rome, Italy
| |
Collapse
|