1
|
Kriener K, Whiting H, Storr N, Homes R, Lala R, Gabrielyan R, Kuang J, Rubin B, Frails E, Sandstrom H, Futter C, Midwinter M. Applied use of biomechanical measurements from human tissues for the development of medical skills trainers: a scoping review. JBI Evid Synth 2023; 21:2309-2405. [PMID: 37732940 DOI: 10.11124/jbies-22-00363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
OBJECTIVE The objective of this review was to identify quantitative biomechanical measurements of human tissues, the methods for obtaining these measurements, and the primary motivations for conducting biomechanical research. INTRODUCTION Medical skills trainers are a safe and useful tool for clinicians to use when learning or practicing medical procedures. The haptic fidelity of these devices is often poor, which may be because the synthetic materials chosen for these devices do not have the same mechanical properties as human tissues. This review investigates a heterogeneous body of literature to identify which biomechanical properties are available for human tissues, the methods for obtaining these values, and the primary motivations behind conducting biomechanical tests. INCLUSION CRITERIA Studies containing quantitative measurements of the biomechanical properties of human tissues were included. Studies that primarily focused on dynamic and fluid mechanical properties were excluded. Additionally, studies only containing animal, in silico , or synthetic materials were excluded from this review. METHODS This scoping review followed the JBI methodology for scoping reviews and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR). Sources of evidence were extracted from CINAHL (EBSCO), IEEE Xplore, MEDLINE (PubMed), Scopus, and engineering conference proceedings. The search was limited to the English language. Two independent reviewers screened titles and abstracts as well as full-text reviews. Any conflicts that arose during screening and full-text review were mediated by a third reviewer. Data extraction was conducted by 2 independent reviewers and discrepancies were mediated through discussion. The results are presented in tabular, figure, and narrative formats. RESULTS Data were extracted from a total of 186 full-text publications. All of the studies, except for 1, were experimental. Included studies came from 33 countries, with the majority coming from the United States. Ex vivo methods were the predominant approach for extracting human tissue samples, and the most commonly studied tissue type was musculoskeletal. In this study, nearly 200 unique biomechanical values were reported, and the most commonly reported value was Young's (elastic) modulus. The most common type of mechanical test performed was tensile testing, and the most common reason for testing human tissues was to characterize biomechanical properties. Although the number of published studies on biomechanical properties of human tissues has increased over the past 20 years, there are many gaps in the literature. Of the 186 included studies, only 7 used human tissues for the design or validation of medical skills training devices. Furthermore, in studies where biomechanical values for human tissues have been obtained, a lack of standardization in engineering assumptions, methodologies, and tissue preparation may implicate the usefulness of these values. CONCLUSIONS This review is the first of its kind to give a broad overview of the biomechanics of human tissues in the published literature. With respect to high-fidelity haptics, there is a large gap in the published literature. Even in instances where biomechanical values are available, comparing or using these values is difficult. This is likely due to the lack of standardization in engineering assumptions, testing methodology, and reporting of the results. It is recommended that journals and experts in engineering fields conduct further research to investigate the feasibility of implementing reporting standards. REVIEW REGISTRATION Open Science Framework https://osf.io/fgb34.
Collapse
Affiliation(s)
- Kyleigh Kriener
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Harrison Whiting
- Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
- School of Clinical Medicine, Royal Brisbane Clinical Unit, The University of Queensland, Brisbane, QLD, Australia
| | - Nicholas Storr
- Gold Coast University Hospital, Southport, QLD Australia
| | - Ryan Homes
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Raushan Lala
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Robert Gabrielyan
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
- Ochsner Clinical School, Jefferson, LA, United States
| | - Jasmine Kuang
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
- Ochsner Clinical School, Jefferson, LA, United States
| | - Bryn Rubin
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
- Ochsner Clinical School, Jefferson, LA, United States
| | - Edward Frails
- Department of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA, United States
| | - Hannah Sandstrom
- Department of Exercise Science and Sport Management, Kennesaw State University, Kennesaw, GA, United States
| | - Christopher Futter
- Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
- Anaesthesia and Intensive Care Program, Herston Biofabrication institute, Brisbane, QLD, Australia
| | - Mark Midwinter
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| |
Collapse
|
2
|
Bui NT, Kazemi A, Sit AJ, Larson NB, Greenleaf J, Chen JJ, Zhang X. Non-invasive Measurement of the Viscoelasticity of the Optic Nerve and Sclera for Assessing Papilledema: A Pilot Clinical Study. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:2227-2233. [PMID: 37517885 PMCID: PMC10529623 DOI: 10.1016/j.ultrasmedbio.2023.07.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 07/06/2023] [Accepted: 07/09/2023] [Indexed: 08/01/2023]
Abstract
OBJECTIVE The purpose of this study was to evaluate our novel ultrasound vibro-elastography (UVE) technique for assessing patients with papilledema by non-invasively measuring shear wave speed (SWS), elasticity and viscosity properties of the optic nerve and sclera. METHODS Shear wave speeds were measured at three frequencies-100, 150 and 200 Hz-on the optic nerve and sclera tissues for assessing patients with papilledema resulting from idiopathic intracranial hypertension (IIH). The method was evaluated in six papilledema patients and six controls on two separate locations for each participant (i.e., optic nerve and posterior sclera). SWSs of the optic nerve and sclera were analyzed by using a 2-D speed map technique within a circular region of interest (ROI) (i.e., the diameter of the ROI was 1.5 mm × 3.0 mm at the optic nerve and sclera, respectively). Elasticity and viscosity were then analyzed using the wave speed dispersion over the three frequencies. RESULTS We measured values of SWS at both locations, optic nerve and sclera, of the right eye and left eye at three different frequencies in IIH patients and controls. The SWS (mean ± standard deviation [m/s]) of the right eye was significantly higher at the sclera in IIH patients compared with controls (i.e., patients vs. controls: 5.91 ± 0.54 vs. 3.86 ± 0.56, p < 0.0001 at 100 Hz), but there was no significant difference at the optic nerve (i.e., patients vs. controls: 3.62 ± 0.39 vs. 3.36 ± 0.35, p = 0.1100 at 100Hz). We observed increased elasticity (kPa) in IIH patients, indicating there are significant differences in elasticity between patients and controls at the optic nerve and sclera (i.e., right eye [patients vs. controls]: 14.42 ± 6.59 vs. 6.5 ± 5.71, p = 0.0065 [optic nerve]; 33.04 ± 10.62 vs. 9.16 ± 7.15, p < 0.0001 [sclera]). Viscosity was also (Pa·s) higher in the sclera and optic nerve of the left eye (i.e., left eye [patient vs. control]: 8.89 ± 4.37 vs. 7.27 ± 5.01, p = 0.3790 (optic nerve); 16.05 ± 10.79 vs. 8.49 ± 6.09, p < 0.0194 [sclera]). CONCLUSION This research illustrates the feasibility of using our UVE system to evaluate stiffness of different tissues in the eye non-invasively. It suggests that the viscoelasticity of the posterior sclera is higher than that of the optic nerve. We found that the posterior sclera is stiffer than the optic nerve in patients with papilledema resulting from IIH, making UVE a potential non-invasive technique for assessing papilledema.
Collapse
Affiliation(s)
- Ngoc Thang Bui
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Arash Kazemi
- Department of Ophthalmology, Mayo Clinic, Rochester, MN, USA
| | - Arthur J Sit
- Department of Ophthalmology, Mayo Clinic, Rochester, MN, USA
| | | | - James Greenleaf
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - John J Chen
- Department of Ophthalmology, Mayo Clinic, Rochester, MN, USA; Department of Neurology, Mayo Clinic, Rochester, MN, USA
| | - Xiaoming Zhang
- Department of Radiology, Mayo Clinic, Rochester, MN, USA; Department of Ophthalmology, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
3
|
Arnold N, Scott J, Bush TR. A review of the characterizations of soft tissues used in human body modeling: Scope, limitations, and the path forward. J Tissue Viability 2023; 32:286-304. [PMID: 36878737 DOI: 10.1016/j.jtv.2023.02.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 02/06/2023] [Accepted: 02/10/2023] [Indexed: 02/27/2023]
Abstract
Soft tissue material properties are vital to human body models that evaluate interactions between the human body and its environment. Such models evaluate internal stress/strain responses in soft tissues to investigate issues like pressure injuries. Numerous constitutive models and parameters have been used to represent mechanical behavior of soft tissues in biomechanical models under quasi-static loading. However, researchers reported that generic material properties cannot accurately represent specific target populations due to large inter-individual variability. Two challenges that exist are experimental mechanical characterization and constitutive modeling of biological soft tissues and personalization of constitutive parameters using non-invasive, non-destructive bedside testing methods. It is imperative to understand the scope and appropriate applications for reported material properties. Thus, the goal of this paper was to compile studies from which soft tissue material properties were obtained and categorize them by source of tissue samples, methods used to quantify deformation, and material models used to describe tissues. The collected studies displayed wide ranges of material properties, and factors that affected the properties included whether tissue samples were in vivo or ex vivo, from humans or animals, the body region tested, body position during in vivo studies, deformation measurements, and material models used to describe tissues. Because of the factors that affected reported material properties, it is clear that much progress has been made in understanding soft tissue responses to loading, yet there is a need to broaden the scope of reported soft tissue material properties and better match reported properties to appropriate human body models.
Collapse
Affiliation(s)
- Nicole Arnold
- Department of Mechanical Engineering, Michigan State University, 428 S Shaw Lane, Rm. 2555 Engineering Building, East Lansing, MI, 48824-1226, USA
| | - Justin Scott
- Department of Mechanical Engineering, Michigan State University, 428 S Shaw Lane, Rm. 2555 Engineering Building, East Lansing, MI, 48824-1226, USA
| | - Tamara Reid Bush
- Department of Mechanical Engineering, Michigan State University, 428 S Shaw Lane, Rm. 2555 Engineering Building, East Lansing, MI, 48824-1226, USA.
| |
Collapse
|
4
|
Neumann EE, Doherty S, Bena J, Erdemir A. Role of multi-layer tissue composition of musculoskeletal extremities for prediction of in vivo surface indentation response and layer deformations. PLoS One 2023; 18:e0284721. [PMID: 37083580 PMCID: PMC10121013 DOI: 10.1371/journal.pone.0284721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Accepted: 04/05/2023] [Indexed: 04/22/2023] Open
Abstract
Emergent mechanics of musculoskeletal extremities (surface indentation stiffness and tissue deformation characteristics) depend on the underlying composition and mechanics of each soft tissue layer (i.e. skin, fat, and muscle). Limited experimental studies have been performed to explore the layer specific relationships that contribute to the surface indentation response. The goal of this study was to examine through statistical modeling how the soft tissue architecture contributed to the aggregate mechanical surface response across 8 different sites of the upper and lower extremities. A publicly available dataset was used to examine the relationship of soft tissue thickness (fat and muscle) to bulk tissue surface compliance. Models required only initial tissue layer thicknesses, making them usable in the future with only a static ultrasound image. Two physics inspired models (series of linear springs), which allowed reduced statistical representations (combined locations and location specific), were explored to determine the best predictability of surface compliance and later individual layer deformations. When considering the predictability of the experimental surface compliance, the physics inspired combined locations model showed an improvement over the location specific model (percent difference of 25.4 +/- 27.9% and 29.7 +/- 31.8% for the combined locations and location specific models, respectively). While the statistical models presented in this study show that tissue compliance relies on the individual layer thicknesses, it is clear that there are other variables that need to be accounted for to improve the model. In addition, the individual layer deformations of fat and muscle tissues can be predicted reasonably well with the physics inspired models, however additional parameters may improve the robustness of the model outcomes, specifically in regard to capturing subject specificity.
Collapse
Affiliation(s)
- Erica E Neumann
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States of America
- Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States of America
| | - Sean Doherty
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States of America
- Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States of America
| | - James Bena
- Quantitative Health Sciences, Cleveland Clinic, Cleveland, OH, United States of America
| | - Ahmet Erdemir
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States of America
- Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States of America
| |
Collapse
|
5
|
Doherty S, Landis B, Owings TM, Erdemir A. Template models for simulation of surface manipulation of musculoskeletal extremities. PLoS One 2022; 17:e0272051. [PMID: 35969593 PMCID: PMC9377586 DOI: 10.1371/journal.pone.0272051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Accepted: 07/12/2022] [Indexed: 11/18/2022] Open
Abstract
Capturing the surface mechanics of musculoskeletal extremities would enhance the realism of life-like mechanics imposed on the limbs within surgical simulations haptics. Other fields that rely on surface manipulation, such as garment or prosthetic design, would also benefit from characterization of tissue surface mechanics. Eight homogeneous tissue models were developed for the upper and lower legs and arms of two donors. Ultrasound indentation data was used to drive an inverse finite element analysis for individualized determination of region-specific material coefficients for the lumped tissue. A novel calibration strategy was implemented by using a ratio based adjustment of tissue properties from linear regression of model predicted and experimental responses. This strategy reduced requirement of simulations to an average of under four iterations. These free and open-source specimen-specific models can serve as templates for simulations focused on mechanical manipulations of limb surfaces.
Collapse
Affiliation(s)
- Sean Doherty
- Department of Biomedical Engineering and Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, United States of America
| | - Ben Landis
- Department of Biomedical Engineering and Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, United States of America
| | - Tammy M. Owings
- Department of Biomedical Engineering and Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, United States of America
| | - Ahmet Erdemir
- Department of Biomedical Engineering and Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, United States of America
- * E-mail:
| |
Collapse
|
6
|
Bosnic M, Rasoulian A, Brandon S. Investigating the Effects of Activation State and Location on Lower Limb Tissue Stiffness. J Biomech 2022; 135:111032. [DOI: 10.1016/j.jbiomech.2022.111032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 02/12/2022] [Accepted: 02/28/2022] [Indexed: 10/18/2022]
|
7
|
Prince M, Kenney LP, Howard D. A pin-array method for capturing tissue deformation under defined pressure distributions and its application to prosthetic socket design. Med Eng Phys 2020; 84:136-143. [PMID: 32977910 DOI: 10.1016/j.medengphy.2020.08.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Revised: 07/09/2020] [Accepted: 08/06/2020] [Indexed: 01/02/2023]
Abstract
The Fit4Purpose project aims to develop upper limb prosthetic devices which are suitable for deployment in lower- and middle-income countries (LMIC's). Open-frame trans-radial socket designs are being considered, formed of several, linked components, including pads which interface directly with the skin surface. A mechanical tool has been developed to aid the design of pad shapes, using an array of square brass bars of varying lengths (i.e. a pin-array) to apply a chosen normal pressure distribution to an area of tissue. The shape to which the tissue is displaced can then be captured by clamping the bars together to fix their relative positions. The device is described, then three short studies are used to demonstrate its use on the forearm of a single, anatomically intact subject. The first investigates the effect of array size on the measured surface stiffness, finding an inverse relationship with a similar characteristic to previous published results. The second tests the hypothesis that a pad with a shape which duplicates that captured by the device will generate a similar overall load to the original pins if applied to the same region of tissue. The results support the hypothesis, but also highlight the sensitivity of the interface loading to the underlying muscle activation. Finally, the tool is used to demonstrate that different tissue displacements are observed when the same pressure distribution is applied to different areas of the forearm. Whilst the tool itself is a simple device, and the techniques used are not sophisticated, the studies suggest that the approach could be useful in pad design. Although it is clearly not appropriate for clinical application in its current form, there may be potential to develop the concept into a more practical device. Other applications could include the design of other devices which interface with the skin, the generation of data for validation of finite element models, including the application of known pressure distributions and tissue deformations during Magnetic Resonance Imaging, and the assessment of matrix pressure sensing devices on compliant materials with complex geometries.
Collapse
Affiliation(s)
- Michael Prince
- Centre for Health Sciences Research, University of Salford, PO33 Brian Blatchford Building, Frederick Road Campus, M6 6PU, United Kingdom.
| | - Laurence Pj Kenney
- Centre for Health Sciences Research, University of Salford, PO43 Brian Blatchford Building, Frederick Road Campus, M6 6PU, United Kingdom
| | - Dave Howard
- Centre for Health Sciences Research, University of Salford, Newton Building Room UG3, Frederick Road Campus, M6 6PU, United Kingdom
| |
Collapse
|