1
|
Kim B, Kelly TAN, Jung HJ, Beane OS, Bhumiratana S, Bouklas N, Cohen I, Bonassar LJ. Microscale strain concentrations in tissue-engineered osteochondral implants are dictated by local compositional thresholds and architecture. J Biomech 2024; 162:111882. [PMID: 38070296 DOI: 10.1016/j.jbiomech.2023.111882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 10/16/2023] [Accepted: 11/20/2023] [Indexed: 01/16/2024]
Abstract
Tissue-engineered osteochondral implants manufactured from condensed mesenchymal stem cell bodies have shown promise for treating focal cartilage defects. Notably, such manufacturing techniques have shown to successfully recapture the bulk mechanical properties of native cartilage. However, the relationships among the architectural features, local composition, and micromechanical environment within tissue-engineered cartilage from cell-based aggregates remain unclear. Understanding such relationships is crucial for identifying critical parameters that can predict in vivo performance. Therefore, this study investigated the relationship among architectural features, composition, and micromechanical behavior of tissue-engineered osteochondral implants. We utilized fast-confocal microscopy combined with a strain mapping technique to analyze the micromechanical behavior under quasi-static loading, as well as Fourier Transform Infrared Spectroscopy to analyze the local compositions. More specifically, we investigated the architectural features and compositional distributions generated from tissue maturation, along with macro- and micro-level strain distributions. Our results showed that under compression, cell-based aggregates underwent deformation followed by body movement, generating high local strain around the boundaries, where local aggrecan concentration was low and local collagen concentration was high. By analyzing the micromechanics and composition at the single aggregate length scale, we identified a strong threshold relationship between local strain and compositions. Namely at the aggrecan concentration below 0.015 arbitrary unit (A.U.) and the collagen concentration above 0.15 A.U., the constructs experienced greater than threefold increase in compressive strain. Overall, this study suggests that local compositional features are the primary driver of the local mechanical environment in tissue-engineered cartilage constructs, providing insight into potential quality control parameters for manufacturing tissue-engineered constructs.
Collapse
Affiliation(s)
- Byumsu Kim
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, United States
| | | | | | | | | | - Nikolaos Bouklas
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, United States
| | - Itai Cohen
- Department of Physics, Cornell University, Ithaca, NY, United States
| | - Lawrence J Bonassar
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, United States; Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, United States.
| |
Collapse
|
2
|
Kim B, Bouklas N, Cohen I, Bonassar LJ. Instabilities induced by mechanical loading determine the viability of chondrocytes grown on porous scaffolds. J Biomech 2023; 152:111591. [PMID: 37088031 DOI: 10.1016/j.jbiomech.2023.111591] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 02/08/2023] [Accepted: 04/11/2023] [Indexed: 04/25/2023]
Abstract
Tissue-engineered cartilage constructs have shown promise to treat focal cartilage defects in multiple clinical studies. Notably, products in clinical use or in late-stage clinical trials often utilize porous collagen scaffolds to provide mechanical support and attachment sites for chondrocytes. Under loading, both the local mechanical responses of collagen scaffolds and the corresponding cellular outcomes are poorly understood, despite their wide use. As such, the architecture of collagen scaffolds varies significantly among tissue-engineered cartilage products, but the effects of such architectures on construct mechanics and cell viability are not well understood. This study investigated the effects of local mechanical responses of collagen scaffolds on chondrocyte viability in tissue-engineered cartilage constructs. We utilized fast confocal microscopy combined with a strain mapping technique to analyze the architecture-dependent instabilities under quasi-static loading and subsequent chondrocyte death in honeycomb and sponge scaffolds. More specifically, we compared the isotropic and the orthotropic planes for each type of collagen scaffold. Under compression, both planes exhibited elastic, buckled, and densified deformation modes. In both loading directions, cell death was minimal in regions that experienced elastic deformation mode and a trend of increase in buckled mode. More interestingly, we saw a significant increase in cell death in densified mode. Overall, this study suggests that local instabilities are directly correlated to chondrocyte death in tissue-engineered cartilage constructs, highlighting the importance of understanding the architecture-dependent local mechanical responses under loading.
Collapse
Affiliation(s)
- Byumsu Kim
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, United States
| | - Nikolaos Bouklas
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, United States
| | - Itai Cohen
- Department of Physics, Cornell University, Ithaca, NY, United States
| | - Lawrence J Bonassar
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, United States; Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, United States.
| |
Collapse
|
3
|
McCorry MC, Reardon KF, Black M, Williams C, Babakhanova G, Halpern JM, Sarkar S, Swami NS, Mirica KA, Boermeester S, Underhill A. Sensor technologies for quality control in engineered tissue manufacturing. Biofabrication 2022; 15:10.1088/1758-5090/ac94a1. [PMID: 36150372 PMCID: PMC10283157 DOI: 10.1088/1758-5090/ac94a1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Accepted: 09/23/2022] [Indexed: 11/11/2022]
Abstract
The use of engineered cells, tissues, and organs has the opportunity to change the way injuries and diseases are treated. Commercialization of these groundbreaking technologies has been limited in part by the complex and costly nature of their manufacture. Process-related variability and even small changes in the manufacturing process of a living product will impact its quality. Without real-time integrated detection, the magnitude and mechanism of that impact are largely unknown. Real-time and non-destructive sensor technologies are key for in-process insight and ensuring a consistent product throughout commercial scale-up and/or scale-out. The application of a measurement technology into a manufacturing process requires cell and tissue developers to understand the best way to apply a sensor to their process, and for sensor manufacturers to understand the design requirements and end-user needs. Furthermore, sensors to monitor component cells' health and phenotype need to be compatible with novel integrated and automated manufacturing equipment. This review summarizes commercially relevant sensor technologies that can detect meaningful quality attributes during the manufacturing of regenerative medicine products, the gaps within each technology, and sensor considerations for manufacturing.
Collapse
Affiliation(s)
- Mary Clare McCorry
- Advanced Regenerative Manufacturing Institute, Manchester, NH 03101, United States of America
| | - Kenneth F Reardon
- Chemical and Biological Engineering and Biomedical Engineering, Colorado State University, Fort Collins, CO 80521, United States of America
| | - Marcie Black
- Advanced Silicon Group, Lowell, MA 01854, United States of America
| | - Chrysanthi Williams
- Access Biomedical Solutions, Trinity, Florida 34655, United States of America
| | - Greta Babakhanova
- National Institute of Standards and Technology, Gaithersburg, MD 20899, United States of America
| | - Jeffrey M Halpern
- Department of Chemical Engineering, University of New Hampshire, Durham, NH 03824, United States of America
- Materials Science and Engineering Program, University of New Hampshire, Durham, NH 03824, United States of America
| | - Sumona Sarkar
- National Institute of Standards and Technology, Gaithersburg, MD 20899, United States of America
| | - Nathan S Swami
- Electrical and Computer Engineering, University of Virginia, Charlottesville, VA 22904, United States of America
| | - Katherine A Mirica
- Department of Chemistry, Dartmouth College, Hanover, NH 03755, United States of America
| | - Sarah Boermeester
- Advanced Regenerative Manufacturing Institute, Manchester, NH 03101, United States of America
| | - Abbie Underhill
- Scientific Bioprocessing Inc., Pittsburgh, PA 15238, United States of America
| |
Collapse
|
4
|
Wyse Jackson T, Michel J, Lwin P, Fortier LA, Das M, Bonassar LJ, Cohen I. Structural origins of cartilage shear mechanics. SCIENCE ADVANCES 2022; 8:eabk2805. [PMID: 35148179 PMCID: PMC8836800 DOI: 10.1126/sciadv.abk2805] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Articular cartilage is a remarkable material able to sustain millions of loading cycles over decades of use outperforming any synthetic substitute. Crucially, how extracellular matrix constituents alter mechanical performance, particularly in shear, remains poorly understood. Here, we present experiments and theory in support of a rigidity percolation framework that quantitatively describes the structural origins of cartilage's shear properties and how they arise from the mechanical interdependence of the collagen and aggrecan networks making up its extracellular matrix. This framework explains that near the cartilage surface, where the collagen network is sparse and close to the rigidity threshold, slight changes in either collagen or aggrecan concentrations, common in early stages of cartilage disease, create a marked weakening in modulus that can lead to tissue collapse. More broadly, this framework provides a map for understanding how changes in composition throughout the tissue alter its shear properties and ultimate in vivo function.
Collapse
Affiliation(s)
- Thomas Wyse Jackson
- Department of Physics, Cornell University, Ithaca, NY, USA
- Corresponding author. (T.W.J.); (I.C.)
| | - Jonathan Michel
- School of Mathematical Sciences, Rochester Institute of Technology, Rochester, NY, USA
| | - Pancy Lwin
- School of Mathematical Sciences, Rochester Institute of Technology, Rochester, NY, USA
| | - Lisa A. Fortier
- Department of Clinical Sciences, Cornell University, Ithaca, NY, USA
| | - Moumita Das
- School of Mathematical Sciences, Rochester Institute of Technology, Rochester, NY, USA
| | - Lawrence J. Bonassar
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, USA
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, USA
| | - Itai Cohen
- Department of Physics, Cornell University, Ithaca, NY, USA
- Corresponding author. (T.W.J.); (I.C.)
| |
Collapse
|
5
|
Gologorsky CJ, Middendorf JM, Cohen I, Bonassar LJ. Depth-dependent patterns in shear modulus of temporomandibular joint cartilage correspond to tissue structure and anatomic location. J Biomech 2021; 129:110815. [PMID: 34706301 DOI: 10.1016/j.jbiomech.2021.110815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 10/07/2021] [Accepted: 10/08/2021] [Indexed: 11/17/2022]
Abstract
To fully understand TMJ cartilage degeneration and appropriate repair mechanisms, it is critical to understand the native structure-mechanics relationships of TMJ cartilage and any local variation that may occur in the tissue. Here, we used confocal elastography and digital image correlation to measure the depth-dependent shear properties as well as the structural properties of TMJ cartilage at different anatomic locations on the condyle to identify depth-dependent changes in shear mechanics and structure. We found that samples at every anatomic location showed qualitatively similar shear modulus profiles as a function of depth. In every sample, four distinct zones of mechanical behavior were observed, with shear modulus values spanning 3-5 orders of magnitude across zones. However, quantitative characteristics of shear modulus profiles varied by anatomic location, particularly zone size and location, with the most significant variation in zonal width occurring in the fibrocartilage surface layer (zone 1). This anatomic variation suggests that different locations on the TMJ condyle may play unique mechanical roles in TMJ function. Furthermore, zones identified in the mechanical data corresponded on a sample-by-sample basis to zones identified in the structural data, indicating the known structural zones of TMJ cartilage may also play unique mechanical roles in TMJ function.
Collapse
Affiliation(s)
| | - Jill M Middendorf
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, USA
| | - Itai Cohen
- Department of Physics, Cornell University, Clark Hall C7, Ithaca, NY 14853, USA
| | - Lawrence J Bonassar
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, USA; Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, USA.
| |
Collapse
|
6
|
Middendorf JM, Diamantides N, Kim B, Dugopolski C, Kennedy S, Blahut E, Cohen I, Bonassar LJ. The influence of chondrocyte source on the manufacturing reproducibility of human tissue engineered cartilage. Acta Biomater 2021; 131:276-285. [PMID: 34245892 DOI: 10.1016/j.actbio.2021.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 06/29/2021] [Accepted: 07/01/2021] [Indexed: 11/16/2022]
Abstract
Multiple human tissue engineered cartilage constructs are showing promise in advanced clinical trials but identifying important measures of manufacturing reproducibility remains a challenge. FDA guidance suggests measuring multiple mechanical properties prior to implantation, because these properties could affect the long term success of the implant. Additionally, these engineered cartilage mechanics could be sensitive to the autologous chondrocyte source, an inherently irregular manufacturing starting material. If any mechanical properties are sensitive to changes in the autologous chondrocyte source, these properties may need to be measured prior to implantation to ensure manufacturing reproducibility and quality. Therefore, this study identified variability in the compressive, friction, and shear properties of a human tissue engineered cartilage constructs due to the chondrocyte source. Over 200 constructs were created from 7 different chondrocyte sources and tested using 3 distinct mechanical experiments. Under confined compression, the compressive properties (aggregate modulus and hydraulic permeability) varied by orders of magnitude due to the chondrocyte source. The friction coefficient changed by a factor of 5 due to the chondrocyte source and high intrapatient variability was noted. In contrast, the shear modulus was not affected by changes in the chondrocyte source. Finally, measurements on the local compressive and shear mechanics revealed variability in the depth dependent strain fields based on chondrocyte source. Since the chondrocyte source causes large amounts of variability in the compression and local mechanical properties of engineered cartilage, these mechanical properties may be important measures of manufacturing reproducibility. STATEMENT OF SIGNIFICANCE: Although the FDA recommends measuring mechanical properties of human tissue engineered cartilage constructs during manufacturing, the effect of manufacturing variability on construct mechanics is unknown. As one of the first studies to measure multiple mechanical properties on hundreds of human tissue engineered cartilage constructs, we found the compressive properties are most sensitive to changes in the autologous chondrocyte source, an inherently irregular manufacturing variable. This sensitivity to the autologous chondrocyte source reveals the compressive properties should be measured prior to implantation to assess manufacturing reproducibility.
Collapse
Affiliation(s)
- Jill M Middendorf
- Sibley School of Mechanical Engineering, Cornell University, Ithaca, NY, United States
| | - Nicole Diamantides
- Meinig School of Biomedical Engineering Cornell University, Ithaca, NY, United States
| | - Byumsu Kim
- Sibley School of Mechanical Engineering, Cornell University, Ithaca, NY, United States
| | | | | | - Eric Blahut
- Histogenics Corporation, Waltham, MA, United States
| | - Itai Cohen
- Department of Physics, Cornell University, Ithaca, NY, United States
| | - Lawrence J Bonassar
- Sibley School of Mechanical Engineering, Cornell University, Ithaca, NY, United States; Meinig School of Biomedical Engineering Cornell University, Ithaca, NY, United States.
| |
Collapse
|
7
|
Statham P, Jones E, Jennings LM, Fermor HL. Reproducing the Biomechanical Environment of the Chondrocyte for Cartilage Tissue Engineering. TISSUE ENGINEERING PART B-REVIEWS 2021; 28:405-420. [PMID: 33726527 DOI: 10.1089/ten.teb.2020.0373] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
It is well known that the biomechanical and tribological performance of articular cartilage is inextricably linked to its extracellular matrix (ECM) structure and zonal heterogeneity. Furthermore, it is understood that the presence of native ECM components, such as collagen II and aggrecan, promote healthy homeostasis in the resident chondrocytes. What is less frequently discussed is how chondrocyte metabolism is related to the extracellular mechanical environment, at both the macro and microscale. The chondrocyte is in immediate contact with the pericellular matrix of the chondron, which acts as a mechanocoupler, transmitting external applied loads from the ECM to the chondrocyte. Therefore, components of the pericellular matrix also play essential roles in chondrocyte mechanotransduction and metabolism. Recreating the biomechanical environment through tuning material properties of a scaffold and/or the use of external cyclic loading can induce biosynthetic responses in chondrocytes. Decellularized scaffolds, which retain the native tissue macro- and microstructure also represent an effective means of recapitulating such an environment. The use of such techniques in tissue engineering applications can ensure the regeneration of skeletally mature articular cartilage with appropriate biomechanical and tribological properties to restore joint function. Despite the pivotal role in graft maturation and performance, biomechanical and tribological properties of such interventions is often underrepresented. This review outlines the role of biomechanics in relation to native cartilage performance and chondrocyte metabolism, and how application of this theory can enhance the future development and successful translation of biomechanically relevant tissue engineering interventions. Impact statement Physiological cartilage function is a key criterion in the success of a cartilage tissue engineering solution. The in situ performance is dependent on the initial scaffold design as well as extracellular matrix deposition by endogenous or exogenous cells. Both biological and biomechanical stimuli serve as key regulators of cartilage homeostasis and maturation of the resulting tissue-engineered graft. An improved understanding of the influence of biomechanics on cellular function and consideration of the final biomechanical and tribological performance will help in the successful development and translation of tissue-engineered grafts to restore natural joint function postcartilage trauma or osteoarthritic degeneration, delaying the requirement for prosthetic intervention.
Collapse
Affiliation(s)
- Patrick Statham
- Institute of Medical and Biological Engineering, Faculty of Biological Sciences, University of Leeds, Leeds, United Kingdom
| | - Elena Jones
- Leeds Institute of Rheumatic and Musculoskeletal Disease, University of Leeds, Leeds, United Kingdom
| | - Louise M Jennings
- Institute of Medical and Biological Engineering, Faculty of Engineering and Physical Sciences, University of Leeds, Leeds, United Kingdom
| | - Hazel L Fermor
- Institute of Medical and Biological Engineering, Faculty of Biological Sciences, University of Leeds, Leeds, United Kingdom
| |
Collapse
|
8
|
Querido W, Kandel S, Pleshko N. Applications of Vibrational Spectroscopy for Analysis of Connective Tissues. Molecules 2021; 26:922. [PMID: 33572384 PMCID: PMC7916244 DOI: 10.3390/molecules26040922] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/30/2021] [Accepted: 02/04/2021] [Indexed: 02/07/2023] Open
Abstract
Advances in vibrational spectroscopy have propelled new insights into the molecular composition and structure of biological tissues. In this review, we discuss common modalities and techniques of vibrational spectroscopy, and present key examples to illustrate how they have been applied to enrich the assessment of connective tissues. In particular, we focus on applications of Fourier transform infrared (FTIR), near infrared (NIR) and Raman spectroscopy to assess cartilage and bone properties. We present strengths and limitations of each approach and discuss how the combination of spectrometers with microscopes (hyperspectral imaging) and fiber optic probes have greatly advanced their biomedical applications. We show how these modalities may be used to evaluate virtually any type of sample (ex vivo, in situ or in vivo) and how "spectral fingerprints" can be interpreted to quantify outcomes related to tissue composition and quality. We highlight the unparalleled advantage of vibrational spectroscopy as a label-free and often nondestructive approach to assess properties of the extracellular matrix (ECM) associated with normal, developing, aging, pathological and treated tissues. We believe this review will assist readers not only in better understanding applications of FTIR, NIR and Raman spectroscopy, but also in implementing these approaches for their own research projects.
Collapse
Affiliation(s)
| | | | - Nancy Pleshko
- Department of Bioengineering, Temple University, Philadelphia, PA 19122, USA; (W.Q.); (S.K.)
| |
Collapse
|
9
|
Irwin RM, Gao T, Boys AJ, Ortved K, Cohen I, Bonassar LJ. Microscale strain mapping demonstrates the importance of interface slope in the mechanics of cartilage repair. J Biomech 2020; 114:110159. [PMID: 33310276 DOI: 10.1016/j.jbiomech.2020.110159] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 11/10/2020] [Accepted: 11/25/2020] [Indexed: 01/20/2023]
Abstract
Achieving lateral integration of articular cartilage repair tissue with surrounding native cartilage remains a clinical challenge. Histological and bulk mechanical studies have identified extracellular matrix components that correlate with superior failure strength, but it is unclear how local changes in geometry and composition at the repair interface affect tissue strains under physiologic loading. Here, we investigated the effects of local compositional and interface geometry on lateral cartilage repair integration by coupling microscale Raman spectroscopy and confocal elastography to measure tissue strains under compressive and shear loading. Histological integration assessments did not have significant relationships with interface strains under compressive loading (p > 0.083) and only the perimeter attachment score was trending towards statistical significance with the |Exy| strain tensor under shear loading (p = 0.050). Interface slope had a stronger correlation with local tissue strains under compressive and shear loading compared to compositional measures of GAG, collagen, or proteins (compressive loading |Eyy| tensor: R2 = 0.400 (interface slope), 0.005 (GAG), 0.024 (collagen), and 0.012 (protein); shear loading |Exy| tensor: R2 = 0.457 (interface slope), 0.003 (GAG), 0.006 (collagen), and 0.000 (total protein)). These data support surgical publications detailing the need for vertical walls when debriding chondral defects. Current histological integration assessments and local compositional measures were insufficient for identifying the variation in interface strains under compressive and shear loading. Thus, our data points to the importance of controlling interface geometry at the time of surgery, which has implications for cartilage repair integration and long-term healing.
Collapse
Affiliation(s)
- Rebecca M Irwin
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, United States
| | - Tianyu Gao
- Department of Materials Science and Engineering, Cornell University, Ithaca, NY, United States
| | - Alexander J Boys
- Department of Materials Science and Engineering, Cornell University, Ithaca, NY, United States
| | - Kyla Ortved
- Comparative Orthopaedics Laboratory, Cornell University, Ithaca, NY, United States(1)
| | - Itai Cohen
- Department of Physics, Cornell University, Ithaca, NY, United States
| | - Lawrence J Bonassar
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, United States; Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, United States.
| |
Collapse
|