1
|
Mohseni F, Rahmani N, Mohseni Bandpei MA, Abdollahi I. Reliability of ultrasonography to measure cervical multifidus, semispinalis cervicis and longus colli muscles dimensions in patients with unilateral cervical disc herniation: An observational cross-sectional test-retest study. J Bodyw Mov Ther 2024; 37:399-403. [PMID: 38432836 DOI: 10.1016/j.jbmt.2023.11.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2022] [Revised: 10/03/2023] [Accepted: 11/06/2023] [Indexed: 03/05/2024]
Abstract
BACKGROUND Ultrasonography (US) has been suggested to assess the morphology and function of cervical muscles; but little is known about the reliability of the US measures in patients with cervical disc herniation (CDH). The purpose of this study was to evaluate within-day inter and intra-rater and between-day intra-rater reliability of US to measure dimensions of deep cervical muscles in patients with unilateral CDH. METHODS Thirty patients with unilateral CDH participated. Anterior-posterior and lateral dimension of longus colli (LC), multifidus (MF) and semispinalis cervicis (SC) were measured using B-mode ultrasound. The measurements were repeated by rater A 1 h (for within-day reliability) and one week (for between-day reliability) later. For inter-rater reliability, rater B performed all muscles measurements like rater A. RESULTS Within-day reliability measurement for all muscles was good to excellent with IntraClass Correlation Coefficients (ICC) ranging from 0.82 to 0.96, standard error of measurement (SEM) from 0.18 to 0.46 and minimal detectable changes (MDC) from 0.43 to 1.09. Between-day reliability was good for all muscle dimensions with ICC ranging from 0.75 to 0.89, SEM from 0.30 to 0.64 and MDC from 0.71 to 1.52. Inter-rater reliability was also good with ICC ranging from 0.75 to 0.89, SEM from 0.34 to 0.65 and MDC from 0.81 to 1.55. CONCLUSIONS US was demonstrated to have high within-day inter and intra-rater and between-day intra-rater reliability to measure muscles dimensions in patients with unilateral CDH. It can be used to assess deep cervical muscles or to monitor the effects of interventions.
Collapse
Affiliation(s)
- Fariba Mohseni
- Physiotherapy Department, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
| | - Nahid Rahmani
- Pediatric Neurorehabilitation Research Center, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.
| | | | - Iraj Abdollahi
- Physiotherapy Department, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
| |
Collapse
|
2
|
Fitze DP, Franchi MV, Peterhans L, Frey WO, Spörri J. Reliability of panoramic ultrasound imaging and agreement with magnetic resonance imaging for the assessment of lumbar multifidus anatomical cross-sectional area. Sci Rep 2023; 13:19647. [PMID: 37949957 PMCID: PMC10638285 DOI: 10.1038/s41598-023-46987-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 11/06/2023] [Indexed: 11/12/2023] Open
Abstract
The aim of this study was to investigate the reliability of panoramic ultrasound (US) imaging and agreement with magnetic resonance imaging (MRI) for assessing the average lumbar multifidus anatomical cross-sectional area between the lumbar vertebral bodies L3-L5 (i.e., LMF ACSAL3-L5). US and MRI scans of 20 male youth competitive alpine skiers were collected. To test the intra- and interrater reliability of US, transversal panoramic scans were analyzed on two different days by the same rater and the analysis of the first day was compared with the analysis of a second rater. To examine the agreement between US and MRI, Bland-Altman analysis was performed. Intrarater reliability was excellent, and interrater reliability was weak to good for both sides. The bias between MRI and US was - 0.19 ± 0.90 cm2 (2.68 ± 12.30%) for the left side and - 0.04 ± 0.98 cm2 (- 1.11 ± 12.93%) for the right side (i.e., for both sides US slightly overestimated LMF ACSAL3-L5 on average). The limits of agreement were - 1.95 to 1.57 cm2 (- 26.70 to 21.30%) for the left side and - 1.95 to 1.88 cm2 (- 26.46 to 24.24%) for the right side. Panoramic US imaging may be considered a method with excellent intrarater and weak to good interrater reliability for assessing LMF ACSAL3-L5. Comparison with MRI showed large individual differences in some cases, but an acceptable bias between the two imaging modalities.
Collapse
Affiliation(s)
- Daniel P Fitze
- Sports Medical Research Group, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
- University Centre for Prevention and Sports Medicine, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
| | - Martino V Franchi
- Sports Medical Research Group, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
- Institute of Physiology, Department of Biomedical Sciences, University of Padua, Padua, Italy
| | - Loris Peterhans
- Sports Medical Research Group, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
- University Centre for Prevention and Sports Medicine, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Walter O Frey
- Sports Medical Research Group, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
- University Centre for Prevention and Sports Medicine, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Jörg Spörri
- Sports Medical Research Group, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
- University Centre for Prevention and Sports Medicine, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| |
Collapse
|
3
|
Luo M, Wang Z, Zhou B, Yang G, Shi Y, Chen J, Tang S, Huang J, Xiao Z. Risk factors for lumbar disc herniation recurrence after percutaneous endoscopic lumbar discectomy: a meta-analysis of 58 cohort studies. Neurosurg Rev 2023; 46:159. [PMID: 37392260 DOI: 10.1007/s10143-023-02041-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 05/18/2023] [Accepted: 05/27/2023] [Indexed: 07/03/2023]
Abstract
Recurrent lumbar disc herniation (rLDH) is one of the most serious complications and major causes of surgical failure and paralysis following percutaneous endoscopic lumbar discectomy (PELD). There are reports in the literature on the identification of risk factors associated with rLDH; however, the results are controversial. Therefore, we conducted a meta-analysis to identify risk factors for rLDH among patients following spinal surgery. PubMed, EMBASE, and the Cochrane Library were searched without language restrictions from inception to April 2018 for studies reporting risk factors for LDH recurrence after PELD. MOOSE guidelines were followed in this meta-analysis. We used a random effects model to aggregate odds ratios (ORs) with 95% confidence intervals (CIs). The evidence of observational studies was classified into high quality (class I), medium quality (class II/III), and low quality (class IV) based on the P value of the total sample size and heterogeneity between studies. Fifty-eight studies were identified with a mean follow-up of 38.8 months. Studies with high-quality (class I) evidence showed that postoperative LDH recurrence after PELD was significantly correlated with diabetes (OR, 1.64; 95% CI, 1.14 to 2.31), the protrusion type LDH (OR, 1.62; 95% CI, 1.02 to 2.61), and less experienced surgeons (OR, 1.54; 95% CI, 1.10 to 2.16). Studies with medium-quality (class II or III) evidence showed that postoperative LDH recurrence was significantly correlated with advanced age (OR, 1.11; 95% CI, 1.05 to 1.19), Modic changes (OR, 2.23; 95% CI, 1.53 to 2.29), smoking (OR, 1.31; 95% CI, 1.00 to 1.71), no college education (OR, 1.56; 95% CI, 1.05 to 2.31), obesity (BMI ≥ 25 kg/m2) (OR, 1.66; 95% CI, 1.11 to 2.47), and inappropriate manual labor (OR, 2.18; 95% CI, 1.33 to 3.59). Based on the current literature, eight patient-related and one surgery-related risk factor are predictors of postoperative LDH recurrence after PELD. These findings may help clinicians raise awareness of early intervention for patients at high risk of LDH recurrence after PELD.
Collapse
Affiliation(s)
- Mingjiang Luo
- Department of Spinal Surgery, Second Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang City, 421000, Hunan Province, China
| | - Zhongze Wang
- Department of Spinal Surgery, Second Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang City, 421000, Hunan Province, China
- Hengyang Medical School, University of South China, Hengyang City, Hunan Province, China
| | - Beijun Zhou
- Hengyang Medical School, University of South China, Hengyang City, Hunan Province, China
| | - Gaigai Yang
- Hengyang Medical School, University of South China, Hengyang City, Hunan Province, China
| | - Yuxin Shi
- Department of Pediatric Dentistry, First Affiliated Hospital (Affiliated Stomatological Hospital) of Xinjiang Medical University, Urumqi, 830054, China
| | - Jiang Chen
- Department of Spinal Surgery, Second Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang City, 421000, Hunan Province, China
| | - Siliang Tang
- Department of Spinal Surgery, Second Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang City, 421000, Hunan Province, China
| | - Jingshan Huang
- Department of Spinal Surgery, Second Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang City, 421000, Hunan Province, China
| | - Zhihong Xiao
- Department of Spinal Surgery, Second Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang City, 421000, Hunan Province, China.
| |
Collapse
|
4
|
Naruse M, Trappe SW, Trappe TA. Human skeletal muscle size with ultrasound imaging: a comprehensive review. J Appl Physiol (1985) 2022; 132:1267-1279. [PMID: 35358402 PMCID: PMC9126220 DOI: 10.1152/japplphysiol.00041.2022] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Skeletal muscle size is an important factor in assessing adaptation to exercise training and detraining, athletic performance, age-associated atrophy and mobility decline, clinical conditions associated with cachexia, and overall skeletal muscle health. Magnetic resonance (MR) imaging and computed tomography (CT) are widely accepted as the gold standard methods for skeletal muscle size quantification. However, it is not always feasible to use these methods (e.g., field studies, bedside studies, large cohort studies). Ultrasound has been available for skeletal muscle examination for more than 50 years and the development, utility, and validity of ultrasound imaging are underappreciated. It is now possible to use ultrasound in situations where MR and CT imaging are not suitable. This review provides a comprehensive summary of ultrasound imaging and human skeletal muscle size assessment. Since the first study in 1968, more than 600 articles have used ultrasound to examine the cross-sectional area and/or volume of 107 different skeletal muscles in more than 27,500 subjects of various ages, health status, and fitness conditions. Data from these studies, supported by decades of technological developments, collectively show that ultrasonography is a valid tool for skeletal muscle size quantification. Considering the wide-ranging connections between human health and function and skeletal muscle mass, the utility of ultrasound imaging will allow it to be employed in research investigations and clinical practice in ways not previously appreciated or considered.
Collapse
Affiliation(s)
- Masatoshi Naruse
- Human Performance Laboratory, Ball State University, Muncie, IN, United States
| | - Scott W Trappe
- Human Performance Laboratory, Ball State University, Muncie, IN, United States
| | - Todd A Trappe
- Human Performance Laboratory, Ball State University, Muncie, IN, United States
| |
Collapse
|
5
|
Naghdi N, Mohseni-Bandpei MA, Taghipour M, Rahmani N. Lumbar Multifidus Muscle Morphology Changes in Patient with Different Degrees of Lumbar Disc Herniation: An Ultrasonographic Study. MEDICINA (KAUNAS, LITHUANIA) 2021; 57:699. [PMID: 34356981 PMCID: PMC8307190 DOI: 10.3390/medicina57070699] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 07/04/2021] [Accepted: 07/05/2021] [Indexed: 11/17/2022]
Abstract
Background and Objective: Previous studies demonstrated that the prevalence of lumbar disc herniation (LDH) is relatively high. This investigation aimed to evaluate the size of lumbar multifidus (LM) muscle in patients with different degrees of LDH compared to healthy group, during rest and contraction, using ultrasonography. Materials and Methods: In this non-experimental, analytic, and case control study, ultrasound imaging was used to assess cross-sectional area (CSA) and thickness of the LM muscle in 15 healthy subjects and 60 patients with different stages of LDH (bulging group = 15, protrusion group = 15, extrusion group = 15, sequestration group = 15). Measurements were taken bilaterally at the L4-L5 level, during rest and contraction and results were compared between groups. Results: There was a significant difference between healthy subjects and the extrusion and sequestration groups during rest and contraction for LM muscle CSA and thickness (p = 0.001), as LM muscle CSA and thickness were significantly smaller in extrusion and sequestration patient groups compared to healthy subjects. LM atrophy was greater in patients with extrusion and sequestration groups than in patients with bulging and protrusion, both at rest and during contraction. Significant correlations were also observed between functional disability and intensity of pain with LM CSA and thickness measurements. Conclusions: Patients with extrusion and sequestration LDH had smaller LM muscle at rest and during contraction compared to healthy subjects. Larger LDH lesions were associated with decreased LM muscle size. Patient with more pain, disability, and extrusion and sequestration LDH had greater LM size changes. LM muscle size was not correlated with symptom duration. Further investigation with greater sample size is warranted.
Collapse
Affiliation(s)
- Neda Naghdi
- Department of Health, Kinesiology & Applied Physiology, Concordia University, Montreal, QC H4B 1R6, Canada;
| | - Mohammad Ali Mohseni-Bandpei
- Pediatric Neurorehabilitation Research Center, University of Social Welfare and Rehabilitation Sciences, Tehran 1985713834, Iran;
| | - Morteza Taghipour
- Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Tehran 1985713834, Iran;
| | - Nahid Rahmani
- Pediatric Neurorehabilitation Research Center, University of Social Welfare and Rehabilitation Sciences, Tehran 1985713834, Iran;
| |
Collapse
|