1
|
Jalili V, Ghiasvand A, Ebrahimzadeh H, Zendehdel R. Urinary biomonitoring of fuel ether oxygenates using a needle trap device packed with a novel molecularly imprinted polymer surface modified Zeolite Y. J Chromatogr A 2024; 1725:464949. [PMID: 38688054 DOI: 10.1016/j.chroma.2024.464949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 04/15/2024] [Accepted: 04/26/2024] [Indexed: 05/02/2024]
Abstract
This study introduces an innovative needle trap device (NTD) featuring a molecularly imprinted polymer (MIP) surface-modified Zeolite Y. The developed NTD was integrated with gas chromatography-flame ionization detector (GC-FID) and employed for analysis of fuel ether oxygenates (methyl tert‑butyl ether, MTBE, ethyl tert‑butyl ether, ETBE, and tert‑butyl formate, TBF) in urine samples. To optimize the key experimental variables including extraction temperature, extraction time, salt concentration, and stirring speed, a central composite design-response surface methodology (CCD-RSM) was employed. The optimal values for extraction in the study were found to be 51.2 °C extraction temperature, 46.2 min extraction time, 27 % salt concentration, and 620 rpm stirring speed. Under the optimized conditions, the calibration curves demonstrated excellent linearity within the range of 0.1-100 μg L-1, with correlation coefficients (R2) exceeding 0.99. The limits of detection (LODs) for MTBE, ETBE, and TBF were obtained 0.06, 0.08, and 0.09 μg L-1, respectively. Moreover, the limits of quantification (LOQs) for MTBE, ETBE, and TBF were obtained 0.18, 0.24, and 0.27 μg L-1, respectively. The enrichment factor was also found to be in the range of 98-129.The NTD-GC-FID procedure demonstrated a high extraction efficiency, making it a promising tool for urinary biomonitoring of fuel ether oxygenates with improved sensitivity and selectivity compared to current methods.
Collapse
Affiliation(s)
- Vahid Jalili
- Department of Occupational Health Engineering, School of Public Health and safety, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Alireza Ghiasvand
- Department of Analytical Chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Homeira Ebrahimzadeh
- Department of Analytical Chemistry and Pollutants, Faculty of Chemistry and Petroleum Sciences, Shahid Beheshti University, Tehran, Iran
| | - Rezvan Zendehdel
- Department of Occupational Health Engineering, School of Public Health and safety, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
2
|
Han Z, Li G, Li M, Zhang Y, Meng Z. Ordered mesoporous hairbrush-like nanocarbon assembled microfibers for solid-phase microextraction of benzene series in oilfield sewage. ANAL SCI 2024; 40:1031-1041. [PMID: 38642247 DOI: 10.1007/s44211-024-00506-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Accepted: 01/04/2024] [Indexed: 04/22/2024]
Abstract
The development of advanced functional nanomaterials for solid-phase microextraction (SPME) remains an imperative aspect of sample pretreatment. Herein, we introduce a novel SPME fiber consisting of graphene fibers modified with ordered mesoporous carbon nanotubes arrays (CNTAs) tailored for the determination of benzene series in oilfield wastewater, which is synthesized by an ionic liquid-assisted wet spinning process of graphene nanosheets, followed by a precisely controlled growth of metal-organic framework and subsequent pyrolysis treatment. The resulting robust microfiber structure resembles a "hairbrush" configuration, with a crumpled graphene fiber "stem" and high-order mesoporous CNTAs "hairs". This unique architecture significantly enhances the SPME capacity, as validated by gas chromatography-mass spectrometry. The hairbrush-like nanocarbon assembled microfibers possess structural characteristics, a high specific surface area, and numerous binding sites, offering efficient enrichment of benzene series compounds in oilfield wastewater, including benzene, ethylbenzene, m-xylene, p-xylene, and toluene. Our analysis demonstrates that these microfibers exhibit broad linear ranges (0.2-600 μg L-1), low detection limits (0.005-0.03 mg L-1), and excellent repeatability (3.2-5.5% for one fiber, 2.1-6.7% for fiber-to-fiber) for detection. When compared to commercial alternatives, these hairbrush-like nanocarbon-assembled microfibers exhibit significantly enhanced extraction efficiency for benzene series compounds.
Collapse
Affiliation(s)
- Zhuo Han
- Technology Inspection Center of ShengLi Oilfiled Branch, China Petrochemical Corporation, Dongying, 257000, People's Republic of China
| | - Gangzhu Li
- Technology Inspection Center of ShengLi Oilfiled Branch, China Petrochemical Corporation, Dongying, 257000, People's Republic of China.
| | - Mo Li
- Technology Inspection Center of ShengLi Oilfiled Branch, China Petrochemical Corporation, Dongying, 257000, People's Republic of China
| | - Yanbo Zhang
- Technology Inspection Center of ShengLi Oilfiled Branch, China Petrochemical Corporation, Dongying, 257000, People's Republic of China
| | - Zhaoyu Meng
- Technology Inspection Center of ShengLi Oilfiled Branch, China Petrochemical Corporation, Dongying, 257000, People's Republic of China
| |
Collapse
|
3
|
Magnetic Nanomaterials and Nanostructures in Sample Preparation Prior to Liquid Chromatography. MAGNETOCHEMISTRY 2022. [DOI: 10.3390/magnetochemistry8030029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Magnetic nanomaterials and nanostructures compose an innovative subject in sample preparation. Most of them are designed according to the properties of the target analytes on each occasion. The unique characteristics of nanomaterials enhance the proficiency at extracting and enriching due to their selective adsorption ability as well as easy separation and surface modification. Their remarkable properties, such as superparamagnetism, biocompatibility and selectivity have established magnetic materials as very reliable options in sample preparation approaches. In order to comprehend the range of utilization at magnetic materials and nanostructures, this review aims to present the most notable examples in sample preparation prior to liquid chromatography (LC) to the community of analytical chemists. Primarily, the review describes the principles of the techniques in which the magnetic materials are utilized and leaned on. Additionally, there is a diligent report about the novel magnetic techniques and finally a comparison to demonstrate the total point of view.
Collapse
|
4
|
A comprehensive review on microextraction techniques for sampling and analysis of fuel ether oxygenates in different matrices. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106437] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
5
|
Jagirani MS, Soylak M. A review: Recent advances in solid phase microextraction of toxic pollutants using nanotechnology scenario. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105436] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
6
|
Ghanbarian M, Nazmara S, Masinaei M, Ghanbarian M, Mahvi AH. Evaluating the exposure of general population of Tehran with volatile organic compounds (BTEX). INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY 2020. [DOI: 10.1080/03067319.2020.1781839] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Maryam Ghanbarian
- School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
- Office of Environment and Occupational Health, Ministry of Health and Medical Education, Tehran, Iran
| | - Shahrokh Nazmara
- School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
| | - Masoud Masinaei
- Department of Epidemiology and Biostatistics, Tehran University of Medical Sciences, Tehran, Iran
| | - Marjan Ghanbarian
- School of Public Health, Shahroud University of Medical Sciences, Shahroud, Iran
| | - Amir Hossein Mahvi
- School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
- Center for Solid Waste Research, Institute for Environmental Research, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
7
|
Zhou X, Xie Y, Zhao Z, Fu W. A simple strategy based on fibers coated with surfactant-functionalized multiwalled carbon nanotubes to improve the properties of solid-phase microextraction of phenols in aqueous solution. BMC Chem 2020; 14:15. [PMID: 32099973 PMCID: PMC7029595 DOI: 10.1186/s13065-020-00665-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2019] [Accepted: 01/30/2020] [Indexed: 02/19/2023] Open
Abstract
Methods and experiments In this study, a functionalized multiwalled carbon nanotube (MWCNT)-coated solid-phase microextraction (SPME) fiber was developed for concentrating analytes in aqueous samples. Sodium deoxycholate (NaDC) was used as a dispersing agent for non-covalent modification of MWCNTs. The coating showed porous structure and large adsorption capacity. To investigate the capability of this MWCNTs/NaDC SPME fiber, it was applied to the analysis of phenols in aqueous solution. After extraction, the analytes were desorbed in an acetonitrile–water solution and analyzed using high-performance liquid chromatography. Results The MWCNTs/NaDC fiber exhibited good analytical performance, and fine preparation reproducibility was obtained with the relative standard deviations (RSDs) ranging from 4.9% to 10.2% (n = 6) in one batch, from 5.7% to 11.9% (n = 3) among different batches. Under the optimum extraction conditions, the detection limits were 0.15–0.30 ng/mL(S/N = 3), the linear detection ranges were 1–100 ng/mL (R2 ≥ 0.9997) for these analytes, and good recoveries (80.3–95.4%) were obtained for the spiked samples. Conclusion This is a simple and accurate pretreatment method for the analysis of phenols in aqueous samples.
Collapse
Affiliation(s)
- Xueqing Zhou
- 1Analytical and Testing Center, Hainan University, Haikou, 570228 China.,2College of Materials and Chemical Engineering, Hainan University, Haikou, 570228 China
| | - Yanli Xie
- 1Analytical and Testing Center, Hainan University, Haikou, 570228 China
| | - Zhendong Zhao
- 1Analytical and Testing Center, Hainan University, Haikou, 570228 China
| | - Wenyan Fu
- 2College of Materials and Chemical Engineering, Hainan University, Haikou, 570228 China
| |
Collapse
|
8
|
Darabi J, Ghiasvand A. Chromium-Based Polypyrrole/MIL-101 Nanocomposite as an Effective Sorbent for Headspace Microextraction of Methyl tert-Butyl Ether in Soil Samples. Molecules 2020; 25:molecules25030644. [PMID: 32028571 PMCID: PMC7037173 DOI: 10.3390/molecules25030644] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 01/31/2020] [Accepted: 01/31/2020] [Indexed: 11/16/2022] Open
Abstract
The performance of headspace solid-phase microextraction (HS-SPME) was upgraded by easy and low-cost preparation of a new nanocomposite fiber. A polypyrrole/chromium-based metal–organic framework, PPy@MIL-101(Cr), nanocomposite was electrochemically synthesized and simultaneously coated on a steel wire as a microextraction sorbent. The morphology and chemical structure of the prepared nanocomposite was characterized by Fourier-transform infrared spectrometry (FT-IR), scanning electron microscopy (SEM), and energy dispersive X-ray analysis (EDX) techniques. The microsorbent was used for sampling of methyl-tert-butyl ether (MTBE) in solid samples, through an HS-SPME sampling strategy, followed by GC-FID measurement. The optimal experimental conditions, including extraction temperature, extraction time, and GC desorption conditions, were evaluated and optimized. The proposed procedure showed good sensitivity (limit of detection was 0.01 ng·g−1) and precision (relative standard deviation was 8.4% for six replicated analyses). The calibration curve was linear over the range of 5–40,000 ng·g−1, with a correlation coefficient of 0.994. The limit of quantification was 0.4 ng·g−1. The fabricated fiber exhibited good repeatability and reproducibility for the sampling of MTBE, with average recovery values of 88–114%. The intra-fiber and inter-fiber precisions were found to be 8.4% and 19%, respectively. The results demonstrated the superiority of the PPy@MIL-101(Cr)-coated fiber in comparison with handmade (polypyrrole, PPY) and commercial fibers (polyacrylate, PA; polydimethylsiloxane, PDMS; and divinylbenzene/carboxen/polydimethylsiloxane, DVB/CAR/PDMS) for the analysis of solid samples. The developed method was successfully employed for the analysis of MTBE in different soil samples contaminated by oil products.
Collapse
|
9
|
A highly thermal stable solid phase microextraction fiber prepared by an inorganic binder. Anal Chim Acta 2016; 918:35-42. [DOI: 10.1016/j.aca.2016.03.007] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2016] [Revised: 02/29/2016] [Accepted: 03/04/2016] [Indexed: 12/26/2022]
|
10
|
Attari SG, Bahrami A, Shahna FG, Heidari M. Single-walled carbon nanotube/silica composite as a novel coating for solid-phase microextraction fiber based on sol-gel technology. JOURNAL OF ANALYTICAL CHEMISTRY 2015. [DOI: 10.1134/s1061934815100032] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
11
|
Souza-Silva ÉA, Reyes-Garcés N, Gómez-Ríos GA, Boyacı E, Bojko B, Pawliszyn J. A critical review of the state of the art of solid-phase microextraction of complex matrices III. Bioanalytical and clinical applications. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.04.017] [Citation(s) in RCA: 180] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
12
|
Ordered mesoporous carbon film as an effective solid-phase microextraction coating for determination of benzene series from aqueous media. Anal Chim Acta 2015; 888:85-93. [DOI: 10.1016/j.aca.2015.06.055] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2015] [Revised: 06/24/2015] [Accepted: 06/29/2015] [Indexed: 11/23/2022]
|
13
|
Wang L, Hou X, Li J, Liu S, Guo Y. Graphene oxide decorated with silver nanoparticles as a coating on a stainless-steel fiber for solid-phase microextraction. J Sep Sci 2015; 38:2439-46. [DOI: 10.1002/jssc.201500308] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2015] [Revised: 04/21/2015] [Accepted: 04/21/2015] [Indexed: 11/06/2022]
Affiliation(s)
- Licheng Wang
- Key Laboratory of Chemistry of Northwestern Plant Resources, CAS and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics; Chinese Academy of Sciences; Lanzhou China
| | - Xiudan Hou
- Key Laboratory of Chemistry of Northwestern Plant Resources, CAS and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics; Chinese Academy of Sciences; Lanzhou China
- University of Chinese Academy of Sciences; Chinese Academy of Sciences; Beijing China
| | - Jubai Li
- Key Laboratory of Chemistry of Northwestern Plant Resources, CAS and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics; Chinese Academy of Sciences; Lanzhou China
| | - Shujuan Liu
- Key Laboratory of Chemistry of Northwestern Plant Resources, CAS and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics; Chinese Academy of Sciences; Lanzhou China
| | - Yong Guo
- Key Laboratory of Chemistry of Northwestern Plant Resources, CAS and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics; Chinese Academy of Sciences; Lanzhou China
| |
Collapse
|
14
|
Li S, Lu C, Zhu F, Jiang R, Ouyang G. Preparation of C18 composite solid-phase microextraction fiber and its application to the determination of organochlorine pesticides in water samples. Anal Chim Acta 2015; 873:57-62. [DOI: 10.1016/j.aca.2015.03.031] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2014] [Revised: 03/04/2015] [Accepted: 03/22/2015] [Indexed: 01/12/2023]
|
15
|
Wang L, Tang S, Wang S, Liang X, Guo Y. Cadmium sulfide nanoparticles as a novel coating for solid-phase microextraction. J Sep Sci 2015; 38:1326-33. [DOI: 10.1002/jssc.201401261] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2014] [Revised: 01/15/2015] [Accepted: 01/21/2015] [Indexed: 01/15/2023]
Affiliation(s)
- Licheng Wang
- Key Laboratory of Chemistry of Northwestern Plant Resources; CAS and Key Laboratory for Natural Medicine of Gansu Province; Lanzhou Institute of Chemical Physics; Chinese Academy of Sciences; Lanzhou China
| | - Sheng Tang
- Key Laboratory of Chemistry of Northwestern Plant Resources; CAS and Key Laboratory for Natural Medicine of Gansu Province; Lanzhou Institute of Chemical Physics; Chinese Academy of Sciences; Lanzhou China
- University of Chinese Academy of Sciences; Chinese Academy of Sciences; Beijing China
| | - Shuai Wang
- Key Laboratory of Chemistry of Northwestern Plant Resources; CAS and Key Laboratory for Natural Medicine of Gansu Province; Lanzhou Institute of Chemical Physics; Chinese Academy of Sciences; Lanzhou China
| | - Xiaojing Liang
- Key Laboratory of Chemistry of Northwestern Plant Resources; CAS and Key Laboratory for Natural Medicine of Gansu Province; Lanzhou Institute of Chemical Physics; Chinese Academy of Sciences; Lanzhou China
| | - Yong Guo
- Key Laboratory of Chemistry of Northwestern Plant Resources; CAS and Key Laboratory for Natural Medicine of Gansu Province; Lanzhou Institute of Chemical Physics; Chinese Academy of Sciences; Lanzhou China
| |
Collapse
|
16
|
Kang H, Mao Y, Wang X, Zhang Y, Wu J, Wang H. Disposable ionic liquid-coated etched stainless steel fiber for headspace solid-phase microextraction of organophosphorus flame retardants from water samples. RSC Adv 2015. [DOI: 10.1039/c5ra03504j] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
An ionic liquid-coated etched stainless steel fiber was prepared for solid-phase microextraction of organophosphorus flame retardants from water.
Collapse
Affiliation(s)
- Haiyan Kang
- School of Municipal and Environmental Engineering
- Henan University of Urban Construction
- Pingdingshan
- China
| | - Yanli Mao
- School of Municipal and Environmental Engineering
- Henan University of Urban Construction
- Pingdingshan
- China
| | - Xianli Wang
- School of Municipal and Environmental Engineering
- Henan University of Urban Construction
- Pingdingshan
- China
| | - Yan Zhang
- School of Municipal and Environmental Engineering
- Henan University of Urban Construction
- Pingdingshan
- China
| | - Junfeng Wu
- School of Municipal and Environmental Engineering
- Henan University of Urban Construction
- Pingdingshan
- China
| | - Hongqiang Wang
- School of Municipal and Environmental Engineering
- Henan University of Urban Construction
- Pingdingshan
- China
| |
Collapse
|
17
|
Feng X, Li Y, Jing R, Jiang X, Tian M. Detection of organophosphorous pesticides in soil samples with multiwalled carbon nanotubes coating SPME fiber. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY 2014; 93:769-774. [PMID: 25227428 DOI: 10.1007/s00128-014-1379-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2014] [Accepted: 09/08/2014] [Indexed: 06/03/2023]
Abstract
A headspace solid phase microextraction (HS-SPME) technique using stainless steel fiber coated with 20 μm multi-walled carbon nanotubes (MWCNTs) and gas chromatography with thermionic specific detector (GC-TSD) was developed to determine organophosphorous pesticides (OPPs) in soil. Parameters affecting the extraction efficiency such as extraction time and temperature, ionic strength, the volume of water added to the soil, sample solution volume to headspace volume ratio, desorption time, and desorption temperature were investigated and optimized. Compared to commercial polydimethylsiloxane (PDMS, 7 μm) fiber, the PDMS fiber was better to be corrected as phorate, whereas the MWCNTs fiber gave slightly better results for methyl parathion, chlorpyrifos and parathion. The optimized SPME method was applied to analyze OPPs in spiked soil samples. The limits of detection (LODs, S/N = 3) for the four pesticides were <0.216 ng g(-1), and their calibration curves were all linear (r (2) ≥ 0.9908) in the range from 1 to 200 ng g(-1). The precision (RSD, n = 6) for peak areas was 6.5 %-8.8 %. The recovery of the OPPs spiked real soil samples at 50 and 150 ng g(-1) ranged from 89.7 % to 102.9 % and 94.3 % to 118.1 %, respectively.
Collapse
Affiliation(s)
- Xilan Feng
- School of Chemistry and Chemical Engineering, Henan Institute of Science and Technology, Xinxiang, 453003, China
| | | | | | | | | |
Collapse
|
18
|
Matin AA, Biparva P, Gheshlaghi M. Gas chromatographic determination of polycyclic aromatic hydrocarbons in water and smoked rice samples after solid-phase microextraction using multiwalled carbon nanotube loaded hollow fiber. J Chromatogr A 2014; 1374:50-57. [DOI: 10.1016/j.chroma.2014.11.048] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2014] [Revised: 11/14/2014] [Accepted: 11/17/2014] [Indexed: 10/24/2022]
|
19
|
Sanagi MM, Hussain I, Ibrahim WAW, Yahaya N, Kamaruzaman S, Abidin NNZ, Ali I. Micro-extraction of Xenobiotics and Biomolecules from Different Matrices on Nanostructures. SEPARATION AND PURIFICATION REVIEWS 2014. [DOI: 10.1080/15422119.2014.973507] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
20
|
Liang X, Liu S, Wang S, Guo Y, Jiang S. Carbon-based sorbents: Carbon nanotubes. J Chromatogr A 2014; 1357:53-67. [DOI: 10.1016/j.chroma.2014.04.039] [Citation(s) in RCA: 69] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2014] [Revised: 04/11/2014] [Accepted: 04/11/2014] [Indexed: 10/25/2022]
|
21
|
Ghaemi F, Amiri A, Yunus R. Methods for coating solid-phase microextraction fibers with carbon nanotubes. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2014.04.011] [Citation(s) in RCA: 63] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
22
|
Liu H, Liu L, Li Y, Wang X, Du X. Preparation of a Robust and Sensitive Gold-Coated Fiber for Solid-Phase Microextraction of Polycyclic Aromatic Hydrocarbons in Environmental Waters. ANAL LETT 2014. [DOI: 10.1080/00032719.2014.880171] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
23
|
Multiwalled carbon nanotubes-doped polymeric ionic liquids coating for multiple headspace solid-phase microextraction. Talanta 2014; 123:18-24. [DOI: 10.1016/j.talanta.2014.01.030] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2013] [Revised: 01/20/2014] [Accepted: 01/23/2014] [Indexed: 11/23/2022]
|
24
|
Daneshvar Tarigh G, Shemirani F. Development of a selective and pH-independent method for the analysis of ultra trace amounts of nitrite in environmental water samples after dispersive magnetic solid phase extraction by spectrofluorimetry. Talanta 2014; 128:354-9. [PMID: 25059171 DOI: 10.1016/j.talanta.2014.05.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2014] [Revised: 05/06/2014] [Accepted: 05/11/2014] [Indexed: 10/25/2022]
Abstract
This paper describes an innovative and rapidly dispersive magnetic solid phase extraction spectrofluorimetry (DMSPE-FL) method for the analysis of trace amounts of nitrite in some environmental water samples. The method includes derivatization of aqueous nitrite with 2, 3-diaminonaphthalene (DAN), analysis of highly fluorescent 2, 3-naphthotriazole (NAT) derivative using spectrofluorimetry after DSPME. The novelty of our method is based on forming NAT that was independent with the pH-responsive and was adsorbed on MMWCNT by hydrophobic attractions in both acidic and basic media. The extraction efficiency of the sorbent was investigated by extraction of nitrite. The optimum extraction conditions for NO2(-) were obtained as of extraction time, 1.5 min; 10mg sorbent from 160 mL of the sample solution, and elution with 1 mL of acetone/KOH. Under the optimal conditions, the calibration curves were obtained in the range of 0.1-80 µg L(-1) (R(2)=0.999) and LOD (S/N=3) was obtained in 34 ng L(-1). Relative standard deviations (RSD) were 0.6 % (five replicates at 5 μg L(-1)). In addition, the feasibility of the method was demonstrated with extraction and determination of nitrite from some real samples containing tap, mineral, sea, rain, snow and ground waters, with the recovery in standard addition to real matrix of 94-102 % and RSDs of 1.8-10.6%.
Collapse
Affiliation(s)
- Ghazale Daneshvar Tarigh
- Department of Analytical Chemistry, University College of Science, University of Tehran, PO Box 14155-6455, Tehran, Iran.
| | - Farzaneh Shemirani
- Department of Analytical Chemistry, University College of Science, University of Tehran, PO Box 14155-6455, Tehran, Iran.
| |
Collapse
|
25
|
Vatani H, Yazdi AS. Ionic-liquid-mediated poly(dimethylsiloxane)- grafted carbon nanotube fiber prepared by the sol-gel technique for the head space solid-phase microextraction of methyl tert
-butyl ether using GC. J Sep Sci 2013; 37:127-34. [DOI: 10.1002/jssc.201300796] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2013] [Revised: 08/24/2013] [Accepted: 10/17/2013] [Indexed: 11/12/2022]
Affiliation(s)
- Hossein Vatani
- Department of Chemistry, Faculty of Sciences; Ferdowsi University of Mashhad; Mashhad Iran
| | - Ali Sarafraz Yazdi
- Department of Chemistry, Faculty of Sciences; Ferdowsi University of Mashhad; Mashhad Iran
| |
Collapse
|
26
|
Matin AA, Biparva P, Gheshlaghi M, Farhadi K, Gheshlaghi A. Environmental monitoring of complex hydrocarbon mixtures in water and soil samples after solid phase microextraction using PVC/MWCNTs nanocomposite fiber. CHEMOSPHERE 2013; 93:1920-1926. [PMID: 23906812 DOI: 10.1016/j.chemosphere.2013.06.072] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2012] [Revised: 06/22/2013] [Accepted: 06/25/2013] [Indexed: 06/02/2023]
Abstract
A novel nanocomposite based on incorporation of multiwalled carbon nanotubes (MWCNTs) in polyvinyl chloride (PVC) was prepared. Proposed nanocomposite was coated on stainless steel wire by deep coating. Composition of nanocomposite was optimized based on results of morphological studies using scanning electron microscopy. The best composition (83% MWCNTs:17% PVC) was applied as a solid phase microextraction fiber. Complex mixture of aromatic (BTEX) and aliphatic hydrocarbons (C5-C34) were selected as model analytes, and performance of proposed fiber in extraction of the studied compounds from water and soil samples was evaluated. Analytical merits of the method for water samples (LODs=0.10-1.10 ng L(-1), r(2)=0.9940-0.9994) and for soil samples (LODs=0.10-0.77 ng kg(-1), r(2)=0.9946-0.9994) showed excellent characteristics of it in ultra trace determination of petroleum type environmental pollutants. Finally, the method was used for determination of target analytes in river water, industrial effluent and soil samples.
Collapse
Affiliation(s)
- Amir Abbas Matin
- Department of Chemistry, Faculty of Sciences, Azarbijan Shahid Madani University, 53714-161 Tabriz, Iran.
| | | | | | | | | |
Collapse
|
27
|
Zhang D, Xue L, Zhu Q, Du X. A Novel Fiber with Phenyl-Functionalized MSU (Michigan State University) Coating for Solid-Phase Microextraction Combined with High Performance Liquid Chromatography for Preconcentration and Determination of Trace Polychlorinated Biphenyls in Environmental Water Samples. ANAL LETT 2013. [DOI: 10.1080/00032719.2013.789882] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
28
|
|
29
|
A solid-phase microextraction fiber with carbon nanoparticles as sorbent material prepared by a simple flame-based preparation process. J Chromatogr A 2013; 1300:173-9. [DOI: 10.1016/j.chroma.2013.04.061] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2013] [Revised: 04/19/2013] [Accepted: 04/22/2013] [Indexed: 11/19/2022]
|
30
|
Tian J, Xu J, Zhu F, Lu T, Su C, Ouyang G. Application of nanomaterials in sample preparation. J Chromatogr A 2013; 1300:2-16. [DOI: 10.1016/j.chroma.2013.04.010] [Citation(s) in RCA: 161] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2013] [Revised: 03/23/2013] [Accepted: 04/04/2013] [Indexed: 12/07/2022]
|
31
|
|
32
|
Feng J, Qiu H, Liu X, Jiang S, Feng J. The development of solid-phase microextraction fibers with metal wires as supporting substrates. Trends Analyt Chem 2013. [DOI: 10.1016/j.trac.2013.01.015] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
33
|
Rastkari N, Ahmadkhaniha R. Magnetic solid-phase extraction based on magnetic multi-walled carbon nanotubes for the determination of phthalate monoesters in urine samples. J Chromatogr A 2013; 1286:22-8. [DOI: 10.1016/j.chroma.2013.02.070] [Citation(s) in RCA: 95] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2012] [Revised: 02/20/2013] [Accepted: 02/21/2013] [Indexed: 11/24/2022]
|
34
|
Recent advances in nanomaterials utilized in fiber coatings for solid-phase microextraction. Trends Analyt Chem 2013. [DOI: 10.1016/j.trac.2012.09.013] [Citation(s) in RCA: 110] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
35
|
Determination of non-steroidal anti-inflammatory drugs in urine by hollow-fiber liquid membrane-protected solid-phase microextraction based on sol–gel fiber coating. J Chromatogr B Analyt Technol Biomed Life Sci 2012; 908:67-75. [DOI: 10.1016/j.jchromb.2012.09.040] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2012] [Revised: 09/15/2012] [Accepted: 09/21/2012] [Indexed: 11/24/2022]
|
36
|
Azar PA, Tehrani MS, Mohammadiazar S, Husain SW. A novel strategy to increase performance of solid-phase microextraction fibers: Electrodeposition of sol-gel films on highly porous substrate. J Sep Sci 2012; 35:3354-60. [DOI: 10.1002/jssc.201200580] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2012] [Revised: 07/29/2012] [Accepted: 07/29/2012] [Indexed: 11/06/2022]
Affiliation(s)
- Parviz Aberoomand Azar
- Department of Chemistry; Science and Research Branch; Islamic Azad University; Tehran; Iran
| | - Mohammad Saber Tehrani
- Department of Chemistry; Science and Research Branch; Islamic Azad University; Tehran; Iran
| | - Sirwan Mohammadiazar
- Department of Chemistry; Science and Research Branch; Islamic Azad University; Tehran; Iran
| | - Syed Waqif Husain
- Department of Chemistry; Science and Research Branch; Islamic Azad University; Tehran; Iran
| |
Collapse
|
37
|
|
38
|
Herrera-Herrera AV, González-Curbelo MÁ, Hernández-Borges J, Rodríguez-Delgado MÁ. Carbon nanotubes applications in separation science: A review. Anal Chim Acta 2012; 734:1-30. [DOI: 10.1016/j.aca.2012.04.035] [Citation(s) in RCA: 265] [Impact Index Per Article: 22.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2012] [Revised: 04/23/2012] [Accepted: 04/24/2012] [Indexed: 01/08/2023]
|
39
|
Heidari H, Razmi H, Jouyban A. Preparation and characterization of ceramic/carbon coated Fe3O4 magnetic nanoparticle nanocomposite as a solid-phase microextraction adsorbent. J Chromatogr A 2012; 1245:1-7. [DOI: 10.1016/j.chroma.2012.04.046] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2012] [Revised: 04/16/2012] [Accepted: 04/17/2012] [Indexed: 11/25/2022]
|
40
|
Ahmadkhaniha R, Samadi N, Salimi M, Sarkhail P, Rastkari N. Simultaneous determination of parathion, malathion, diazinon, and pirimiphos methyl in dried medicinal plants using solid-phase microextraction fibre coated with single-walled carbon nanotubes. ScientificWorldJournal 2012; 2012:627607. [PMID: 22645439 PMCID: PMC3354778 DOI: 10.1100/2012/627607] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2011] [Accepted: 12/19/2011] [Indexed: 11/25/2022] Open
Abstract
A reliable and sensitive headspace solid-phase microextraction gas chromatography-mass spectrometry method for simultaneous determination of different organophosphorus pesticides in dried medicinal plant samples is described. The analytes were extracted by single-walled carbon nanotubes as a new solid-phase microextraction adsorbent. The developed method showed good performance. For diazinon and pirimiphos methyl calibration, curves were linear (r2 ≥ 0.993) over the concentration ranges from 1.5 to 300 ng g−1, and the limit of detection at signal-to-noise ratio of 3 was 0.3 ng g−1. For parathion and malathion, the linear range and limit of detection were 2.5–300 (r2 ≥ 0.991) and 0.5 ng g−1, respectively. In addition, a comparative study between the single-walled carbon nanotubes and a commercial polydimethylsiloxane fibre for the determination of target analytes was carried out. Single-walled carbon nanotubes fibre showed higher extraction capacity, better thermal stability (over 350°C), and longer lifespan (over 250 times) than the commercial polydimethylsiloxane fibre. The developed method was successfully applied to determine target organophosphorus pesticides in real samples.
Collapse
Affiliation(s)
- Reza Ahmadkhaniha
- Pharmaceutical Sciences Research Center, Tehran University of Medical Sciences, Tehran 14174, Iran
| | | | | | | | | |
Collapse
|
41
|
Towards greater mechanical, thermal and chemical stability in solid-phase microextraction. Trends Analyt Chem 2012. [DOI: 10.1016/j.trac.2011.11.004] [Citation(s) in RCA: 79] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
42
|
Feng J, Sun M, Li J, Liu X, Jiang S. A novel aromatically functional polymeric ionic liquid as sorbent material for solid-phase microextraction. J Chromatogr A 2012; 1227:54-9. [DOI: 10.1016/j.chroma.2012.01.010] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2011] [Revised: 01/03/2012] [Accepted: 01/03/2012] [Indexed: 11/25/2022]
|
43
|
Abstract
Nanoparticles (NPs) have attracted a great deal of attention in the last decade due to their exceptional mechanical, optical and electronic properties. This article deals with the use of NPs as probes for the extraction of biomolecules from biological samples. In this context, NPs present some advantages compared with conventional sorbents. Their high surface-to-volume ratio, easy synthetic (especially for inorganic NPs) and derivatization procedures, and their biocompatibility make them a powerful alternative. In order to provide a systematic approach to the topic, NPs have been divided into two general groups attending to their chemical nature. Carbon-based (e.g., fullerene and nanotubes) and inorganic NPs (e.g., gold and magnetic NPs) are considered in depth, explaining their main properties and applications. After these critical considerations, the most important conclusions and essential trends in this field are also outlined.
Collapse
|
44
|
Zhang S, Du Z, Li G. Layer-by-Layer Fabrication of Chemical-Bonded Graphene Coating for Solid-Phase Microextraction. Anal Chem 2011; 83:7531-41. [DOI: 10.1021/ac201864f] [Citation(s) in RCA: 303] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Suling Zhang
- School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou, 510275, China
| | - Zhuo Du
- School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou, 510275, China
| | - Gongke Li
- School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou, 510275, China
| |
Collapse
|
45
|
Sarafraz-Yazdi A, Amiri A, Rounaghi G, Hosseini HE. A novel solid-phase microextraction using coated fiber based sol–gel technique using poly(ethylene glycol) grafted multi-walled carbon nanotubes for determination of benzene, toluene, ethylbenzene and o-xylene in water samples with gas chromatography-flam ionization detector. J Chromatogr A 2011; 1218:5757-64. [DOI: 10.1016/j.chroma.2011.06.099] [Citation(s) in RCA: 80] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2011] [Revised: 06/23/2011] [Accepted: 06/26/2011] [Indexed: 11/30/2022]
|
46
|
Feng J, Sun M, Xu L, Li J, Liu X, Jiang S. Preparation of metal wire supported solid-phase microextraction fiber coated with multi-walled carbon nanotubes. J Sep Sci 2011; 34:2482-8. [DOI: 10.1002/jssc.201100375] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2011] [Revised: 05/21/2011] [Accepted: 05/21/2011] [Indexed: 11/12/2022]
|
47
|
Solid-phase extraction of lead(II) ions using multiwalled carbon nanotubes grafted with tris(2-aminoethyl)amine. Mikrochim Acta 2011. [DOI: 10.1007/s00604-011-0601-8] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
48
|
Scida K, Stege PW, Haby G, Messina GA, García CD. Recent applications of carbon-based nanomaterials in analytical chemistry: critical review. Anal Chim Acta 2011; 691:6-17. [PMID: 21458626 PMCID: PMC3088727 DOI: 10.1016/j.aca.2011.02.025] [Citation(s) in RCA: 223] [Impact Index Per Article: 17.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2010] [Revised: 01/20/2011] [Accepted: 02/09/2011] [Indexed: 11/19/2022]
Abstract
The objective of this review is to provide a broad overview of the advantages and limitations of carbon-based nanomaterials with respect to analytical chemistry. Aiming to illustrate the impact of nanomaterials on the development of novel analytical applications, developments reported in the 2005-2010 period have been included and divided into sample preparation, separation, and detection. Within each section, fullerenes, carbon nanotubes, graphene, and composite materials will be addressed specifically. Although only briefly discussed, included is a section highlighting nanomaterials with interesting catalytic properties that can be used in the design of future devices for analytical chemistry.
Collapse
Affiliation(s)
- Karen Scida
- Department of Chemistry, The University of Texas at San Antonio, One UTSA Circle, San Antonio, TX, 78249, United States of America
| | - Patricia W. Stege
- INQUISAL, Department of Analytical Chemistry, National University of San Luis – CONICET, Chacabuco y Pedernera. D5700BWS. San Luis, Argentina
| | - Gabrielle Haby
- Department of Chemistry, The University of Texas at San Antonio, One UTSA Circle, San Antonio, TX, 78249, United States of America
| | - Germán A. Messina
- INQUISAL, Department of Analytical Chemistry, National University of San Luis – CONICET, Chacabuco y Pedernera. D5700BWS. San Luis, Argentina
| | - Carlos D. García
- Department of Chemistry, The University of Texas at San Antonio, One UTSA Circle, San Antonio, TX, 78249, United States of America
| |
Collapse
|
49
|
Amini R, Rouhollahi A, Adibi M, Mehdinia A. A novel reusable ionic liquid chemically bonded fused-silica fiber for headspace solid-phase microextraction/gas chromatography-flame ionization detection of methyl tert-butyl ether in a gasoline sample. J Chromatogr A 2011; 1218:130-6. [DOI: 10.1016/j.chroma.2010.10.114] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2010] [Revised: 10/22/2010] [Accepted: 10/26/2010] [Indexed: 10/18/2022]
|
50
|
Farré M, Pérez S, Gonçalves C, Alpendurada M, Barceló D. Green analytical chemistry in the determination of organic pollutants in the aquatic environment. Trends Analyt Chem 2010. [DOI: 10.1016/j.trac.2010.07.016] [Citation(s) in RCA: 75] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|