1
|
Khodarahmian K, Ghiasvand A, Barkhordari A. Exploring the optimal electropolymerization strategy for the preparation of solid-phase microextraction fibers using pyrrole-dopamine copolymers. J Chromatogr A 2024; 1714:464562. [PMID: 38065025 DOI: 10.1016/j.chroma.2023.464562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 11/30/2023] [Accepted: 12/04/2023] [Indexed: 01/05/2024]
Abstract
In-situ electropolymerization of conductive polymers on the surface of stainless-steel substrates is a well-established but promising procedure for the preparation of solid-phase microextraction (SPME) tools. Herein, different electrochemical methods including constant potential (CP), constant potential pulse (CPP), and cyclic voltammetry (CV) were utilized to fabricate SPME fibers by in-situ electropolymerization of pyrrole-dopamine copolymers (PPY/PDA) on the surface of stainless-steel fibers. The coated fibers were characterized and applied for the direct-immersion SPME (DI-SPME) sampling of ultra-trace amounts of plant hormones including abscisic acid (ABA), gibberellic acid (GA3), and indole acetic acid (IAA) in fruit juices, followed by HPLC-UV determination. The results showed that CV electropolymerization is significantly more efficient than the two other methods. The coatings created by the CV method were satisfactorily uniform, adhesive, and durable and exhibited higher extraction performance compared to the CP and CPP procedures. The important experimental variables of the proposed DI-SPME-HPLC method were evaluated and optimized using response surface methodology with a Box-Behnken design. The developed method showed wide-range linearities, spanning from 0.05 to 20μg mL-1 for GA3, and 0.02 to 20μg mL-1 for ABA and IAA. The limits of detection were obtained 0.01μg mL-1 for GA3, and 0.005μg mL-1 for ABA and IAA. The fiber was successfully employed for the simultaneous DI-SPME-HPLC analysis of plant hormones in fruit juice samples.
Collapse
Affiliation(s)
- Kobra Khodarahmian
- Department of Analytical Chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran
| | - Alireza Ghiasvand
- Department of Analytical Chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran.
| | - Abdullah Barkhordari
- Environmental and Occupational Health Research Center, Shahroud University of Medical Sciences, Shahroud, Iran
| |
Collapse
|
2
|
Gurrani S, Prakasham K, Zii Ying JL, Shiea J, Ku YJ, Lin YC, Huang PC, Andaluri G, Lee KC, Ponnusamy VK. A low-cost eco-friendly fast drug extraction (FaDEx) technique for environmental and bio-monitoring of psychoactive drug in urban water and sports-persons' urine samples. ENVIRONMENTAL RESEARCH 2023; 217:114787. [PMID: 36410459 DOI: 10.1016/j.envres.2022.114787] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 10/23/2022] [Accepted: 11/09/2022] [Indexed: 06/16/2023]
Abstract
Nicotine is the most prominent psychoactive/addictive chemical substance consumed worldwide among young players in team sports. Moreover, urinary nicotine discharge and nicotine-based products disposal in environmental waters has been unavoidable in recent years. Therefore, sensitive monitoring of nicotine content in environmental waters and human urine samples is essential. In this study, we developed a miniaturized novel green, low-cost, sensitive, in-syringe-based semi-automated fast drug extraction (FaDEx) protocol coupled with gas chromatography-flame ionization detection (GC-FID) for the efficient environmental and bio-monitoring of nicotine in aqueous samples. The FaDEx method consists of two steps; firstly, the target analyte was extracted using dimethyl carbonate (a green solvent) and extraction salts. After that, the extraction solvent was passed automatically through the solid-phase extraction cartridge at a constant flow rate for the cleanup process to achieve the sensitive nicotine analysis by GC-FID. Under optimized experimental conditions, the developed method showed excellent linearity over the concentration ranges between 20-2000 ng mL-1 with a correlation coefficient >0.99. The detection and quantification limits were 4 and 20 ng mL-1, respectively. The presented method was applied to monitor and assess nicotine exposure in sports-persons' urine and environmental water samples. The method accuracy and precision in terms of relative recovery and relative standard deviation (for triplicate analysis) were 85.4-110.2% and ≤8%, respectively. Finally, the impact of our procedure on the environment from a green analytical chemistry view was assessed using a novel metric system called AGREE, and obtained the greenness score of 0.87, indicating its an efficient alternative green analytical protocol for routine environmental and bio-monitoring of nicotine in environmental and biological samples.
Collapse
Affiliation(s)
- Swapnil Gurrani
- Research Center for Precision Environmental Medicine, and Ph.D. Program in Environmental and Occupational Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan
| | - Karthikeyan Prakasham
- Research Center for Precision Environmental Medicine, and Ph.D. Program in Environmental and Occupational Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan
| | - Jess Lim Zii Ying
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan
| | - Jentaie Shiea
- Research Center for Precision Environmental Medicine, and Ph.D. Program in Environmental and Occupational Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan; Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan; Department of Chemistry, National Sun Yat-Sen University, Kaohsiung City, 804, Taiwan
| | - Yi-Jia Ku
- Research and Development Division, Great Engineering Technology (GETECH) Corporation, No.392, Yucheng Rd., Zuoying District., Kaohsiung City, 813, Taiwan
| | - Yu-Chia Lin
- Research and Development Division, Great Engineering Technology (GETECH) Corporation, No.392, Yucheng Rd., Zuoying District., Kaohsiung City, 813, Taiwan
| | - Po-Chin Huang
- Research Center for Precision Environmental Medicine, and Ph.D. Program in Environmental and Occupational Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan; National Institute of Environmental Health Sciences, National Health Research Institutes (NHRI), Miaoli County, 35053, Taiwan
| | - Gangadhar Andaluri
- Civil and Environmental Engineering Department, College of Engineering, Temple University, Philadelphia, PA 19122, United States
| | - Kung-Che Lee
- Department of Athletic Performace, National University of Kaohsiung, Kaohsiung City, 811, Taiwan.
| | - Vinoth Kumar Ponnusamy
- Research Center for Precision Environmental Medicine, and Ph.D. Program in Environmental and Occupational Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan; Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan; Department of Chemistry, National Sun Yat-Sen University, Kaohsiung City, 804, Taiwan; Department of Medical Research, Kaohsiung Medical University Hospital (KMUH), Kaohsiung City, 807, Taiwan.
| |
Collapse
|
3
|
Tao XY, Zhang Y, Zhou Y, Liu ZF, Feng XS. Nicotine in Complex Samples: Recent Updates on the Pretreatment and Analysis Method. Crit Rev Anal Chem 2021; 53:1209-1238. [PMID: 34955065 DOI: 10.1080/10408347.2021.2016365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/24/2023]
Abstract
Nicotine is a significant evaluation index of tobacco and its related products' quality, but nicotine overdose can pose serious health hazards and cause addiction and dependence, thus it can be seen that it is necessary to find suitable and efficient detection methods to precisely detect nicotine in diverse samples and complex matrices. In this review, an updated summary of the latest trends in pretreatment and analytical techniques for nicotine is provided. We reviewed various sample pretreatment methods, such as solid phase extraction, solid phase microextraction, liquid phase microextraction, QuEChERS, etc., and diverse nicotine assay methods including liquid chromatography, gas chromatography, electrochemical sensors, etc., focusing on the developments since 2015. Furthermore, the recent progress in the applications and applicability of these techniques as well as our prospects for future developments are discussed.HighlightsUpdated pretreatment and analysis methods of nicotine were systematically summarized.Microextraction and automation were main development trends of nicotine pretreatment.The introduction of novel materials added luster to nicotine pretreatment.The evolutions of ion source and mass analyzer were emphasized.
Collapse
Affiliation(s)
- Xin-Yue Tao
- School of Pharmacy, China Medical University, Shenyang, China
- Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| | - Yuan Zhang
- School of Pharmacy, China Medical University, Shenyang, China
| | - Yu Zhou
- Department of Pharmacy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Zhi-Fei Liu
- School of Pharmacy, China Medical University, Shenyang, China
| | - Xue-Song Feng
- School of Pharmacy, China Medical University, Shenyang, China
| |
Collapse
|
4
|
Erdem P, Tağaç AA, Bozkurt SS, Merdivan M. Chitosan and dicationic ionic liquid intercalated clay-coated solid-phase microextraction fiber for determination of sixteen polycyclic aromatic hydrocarbons in coffee and tea samples. Talanta 2021; 235:122764. [PMID: 34517625 DOI: 10.1016/j.talanta.2021.122764] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 07/28/2021] [Accepted: 07/29/2021] [Indexed: 11/18/2022]
Abstract
In the present study, solid-phase microextraction (SPME) fiber was prepared by coating clay (MMT)-chitosan (CH) and dicationic ionic liquid (DIL) onto the stainless-steel wire step by step. The characterization of fibers was performed by Fourier transform infrared spectroscopy, thermal analysis, x-ray diffraction analysis, and scanning electron microscopy. The prepared fibers were evaluated for separation and determination of 16 polycyclic aromatic hydrocarbons (PAHs) in coffee and tea samples in headspace- and direct immersion-SPME by coupling with gas chromatography/mass spectrometry. The analytical performance of MMT/CH/DIL fibers was carried out for the extraction of PAHs and compared with the performance of carboxen/polydimethylsiloxane (CAR/PDMS) and divinylbenzene/CAR/PDMS (DVB/CAR/PDMS) fibers under optimized conditions. The wider linear ranges between 0.001 and 25 μg L-1 with a coefficient of determination above 0.9962, low limits of detection between 0.0001 and 0.05 μg L-1 and good intra-day repeatability from 2.45 to 6.48 % and fiber-to-fiber reproducibility from 3.19 % to 8.82 % were obtained for all PAHs in both methods with MMT/CH/octyl (O)-DIL fiber. The extraction recoveries of coffee and tea samples ranged from 87.5 to 112 % using the MMT/CH/O-DIL fiber in both SPME methods.
Collapse
Affiliation(s)
- Pelin Erdem
- Chemistry Department, Dokuz Eylul University, Tınaztepe Campus, 35390, Izmir, Turkey
| | - Aylin Altınışık Tağaç
- Chemistry Department, Dokuz Eylul University, Tınaztepe Campus, 35390, Izmir, Turkey
| | - Serap Seyhan Bozkurt
- Chemistry Department, Dokuz Eylul University, Tınaztepe Campus, 35390, Izmir, Turkey
| | - Melek Merdivan
- Chemistry Department, Dokuz Eylul University, Tınaztepe Campus, 35390, Izmir, Turkey.
| |
Collapse
|
5
|
Du J, Zhao F, Zeng B. Preparation of functionalized graphene and ionic liquid co-doped polypyrrole solid phase microextraction coating for the detection of benzoates preservatives. Talanta 2021; 228:122231. [DOI: 10.1016/j.talanta.2021.122231] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 02/09/2021] [Accepted: 02/13/2021] [Indexed: 01/12/2023]
|
6
|
Daryanavard SM, Zolfaghari H, Abdel-Rehim A, Abdel-Rehim M. Recent applications of microextraction sample preparation techniques in biological samples analysis. Biomed Chromatogr 2021; 35:e5105. [PMID: 33660303 DOI: 10.1002/bmc.5105] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 01/26/2021] [Accepted: 02/05/2021] [Indexed: 12/11/2022]
Abstract
Analysis of biological samples is affected by interfering substances with chemical properties similar to those of the target analytes, such as drugs. Biological samples such as whole blood, plasma, serum, urine and saliva must be properly processed for separation, purification, enrichment and chemical modification to meet the requirements of the analytical instruments. This causes the sample preparation stage to be of undeniable importance in the analysis of such samples through methods such as microextraction techniques. The scope of this review will cover a comprehensive summary of available literature data on microextraction techniques playing a key role for analytical purposes, methods of their implementation in common biological samples, and finally, the most recent examples of application of microextraction techniques in preconcentration of analytes from urine, blood and saliva samples. The objectives and merits of each microextration technique are carefully described in detail with respect to the nature of the biological samples. This review presents the most recent and innovative work published on microextraction application in common biological samples, mostly focused on original studies reported from 2017 to date. The main sections of this review comprise an introduction to the microextraction techniques supported by recent application studies involving quantitative and qualitative results and summaries of the most significant, recently published applications of microextracion methods in biological samples. This article considers recent applications of several microextraction techniques in the field of sample preparation for biological samples including urine, blood and saliva, with consideration for extraction techniques, sample preparation and instrumental detection systems.
Collapse
Affiliation(s)
| | - Hesane Zolfaghari
- Department of Chemistry, Faculty of Science, University of Hormozgan, Bandar-Abbas, Iran
| | - Abbi Abdel-Rehim
- Department of Chemical Engineering and Biotechnology, Cambridge University, Cambridge, UK
| | - Mohamed Abdel-Rehim
- Functional Materials Division, Department of Applied Physics, School of Engineering Sciences, KTH Royal Institute of Technology, Stockholm, Sweden.,Department of Clinical Neuroscience, Centre for Psychiatry Research, Karolinska Institutet, Solna, Sweden
| |
Collapse
|
7
|
Kim U, Karthikraj R. Solid‐phase microextraction for the human biomonitoring of environmental chemicals: Current applications and future perspectives. J Sep Sci 2020; 44:247-273. [DOI: 10.1002/jssc.202000830] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 10/18/2020] [Accepted: 11/13/2020] [Indexed: 01/09/2023]
Affiliation(s)
- Un‐Jung Kim
- Department of Earth & Environmental Sciences University of Texas at Arlington Arlington Texas USA
| | | |
Collapse
|
8
|
Tashakkori P, Tağaç AA, Merdivan M. Fabrication of montmorillonite/ionic liquid composite coated solid-phase microextraction fibers for determination of phenolic compounds in fruit juices by gas chromatography and liquid chromatography. J Chromatogr A 2020; 1635:461741. [PMID: 33253998 DOI: 10.1016/j.chroma.2020.461741] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 11/18/2020] [Accepted: 11/20/2020] [Indexed: 11/30/2022]
Abstract
Novel montmorillonite composites including ionic liquid were prepared and utilized as coating materials for solid phase microextraction fibers. Ionic liquids containing amino terminated imidazolium cations with methyl and benzyl groups and hydrophobic anions (bis(trifluoromethylsulfonyl)imide) and hydrophilic anions (bromide and tetrafluoroborate) were intercalated to KSF-montmorillonite using stainless steel wire as support by using the layer-by-layer technique. After optimization of experimental conditions, solid phase microextraction (SPME) coupled to gas chromatography/mass spectrometry (SPME-GC/MS) after derivatization by silylation and high performance liquid chromatography/diode array detector (SPME-HPLC/DAD) were developed for the determination of 16 phenolic compounds. The developed SPME-GC/MS method had wider linearity and lower limit of detection than the developed SPME-HPLC/DAD method with similar repeatability (for 5 runs, less than 4.2 %) for a single fiber. The percentage of the variance between two different fibers was less than 6.0 % in both methods. The developed SPME methods were applied successfully to fresh fruit juices and the relative recoveries and the repeatabilities from spiked fruit juice samples were satisfactorily achieved. The results obtained with both chromatographic methods were in good agreement with each other.
Collapse
Affiliation(s)
- Paniz Tashakkori
- Dokuz Eylul University, Graduate School of Natural and Applied Science, Tınaztepe Campus, 35160, Izmir, Turkey
| | - Aylin Altınışık Tağaç
- Dokuz Eylul University, Chemistry Department, Tınaztepe Campus, 35390, Izmir, Turkey
| | - Melek Merdivan
- Dokuz Eylul University, Chemistry Department, Tınaztepe Campus, 35390, Izmir, Turkey.
| |
Collapse
|
9
|
Zali S, Es-haghi A, Shamsipur M, Jalali F. Electrospun nanofibers as a new solid phase microextraction coating for determination of volatile organic impurities in biological products. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1153:122279. [DOI: 10.1016/j.jchromb.2020.122279] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 07/13/2020] [Accepted: 07/20/2020] [Indexed: 01/11/2023]
|
10
|
Godage NH, Cudjoe E, Neupane R, Boddu SHS, Bolla PK, Renukuntla J, Gionfriddo E. Biocompatible SPME fibers for direct monitoring of nicotine and its metabolites at ultra trace concentration in rabbit plasma following the application of smoking cessation formulations. J Chromatogr A 2020; 1626:461333. [DOI: 10.1016/j.chroma.2020.461333] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Revised: 05/31/2020] [Accepted: 06/07/2020] [Indexed: 02/06/2023]
|
11
|
Heating-, Cooling- and Vacuum-Assisted Solid-Phase Microextraction (HCV-SPME) for Efficient Sampling of Environmental Pollutants in Complex Matrices. Chromatographia 2020. [DOI: 10.1007/s10337-020-03869-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
12
|
Ahmad SM, Nogueira JMF. High throughput bar adsorptive microextraction: A simple and effective analytical approach for the determination of nicotine and cotinine in urine samples. J Chromatogr A 2019; 1615:460750. [PMID: 31866132 DOI: 10.1016/j.chroma.2019.460750] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 11/27/2019] [Accepted: 11/28/2019] [Indexed: 01/08/2023]
Abstract
A simple, effective, convenient and environmentally friendly methodology using high throughput bar adsorptive microextraction (HT-BAμE) with microliquid desorption in combination with large volume injection-gas chromatography-mass spectrometry operating in the selected-ion monitoring acquisition mode (LVI-GC-MS(SIM)) was applied for the determination of nicotine and cotinine in urine samples. Under optimized experimental conditions, the developed methodology allowed for linear dynamic ranges between 20.0 and 2000.0 μg L-1 with determination coefficients of 0.9991 and 0.9992, as well as average recovery yields of 61.7-67.5% and 53.9-57.8% for nicotine and cotine, respectively. The developed methodology was applied to monitor urine samples from 86 volunteers having different smoking habits, where nicotine and cotinine were quantified in the range from 23.6 to 2612.6 μg L-1. The target compounds were extracted in a HT-BAμE apparatus, which allows for simultaneous microextraction and subsequent back-extraction of up to 100 samples. This is a major improvement over other microextraction techniques. The data from the proposed methodology were satisfactory and in line with current green analytical chemistry guidelines, and proved to be an effective sample preparation alternative with substantial potential for high throughput bioanalysis.
Collapse
Affiliation(s)
- S M Ahmad
- Centro de Química e Bioquímica e Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa, Portugal
| | - J M F Nogueira
- Centro de Química e Bioquímica e Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa, Portugal.
| |
Collapse
|
13
|
Pelit L, Pelit F, Ertaş H, Ertaş FN. Electrochemically Fabricated Solid Phase Microextraction Fibers and Their Applications in Food, Environmental and Clinical Analysis. CURR ANAL CHEM 2019. [DOI: 10.2174/1573411015666190314155440] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Background:Designing an analytical methodology for complicated matrices, such as biological and environmental samples, is difficult since the sample preparation procedure is the most demanding step affecting the whole analytical process. Nowadays, this step has become more challenging by the legislations and environmental concerns since it is a prerequisite to eliminate or minimize the use of hazardous substances in traditional procedures by replacing with green techniques suitable for the sample matrix.Methods:In addition to the matrix, the nature of the analyte also influence the ease of creating green analytical techniques. Recent developments in the chemical analysis provide us new methodologies introducing microextraction techniques and among them, solid phase microextraction (SPME) has emerged as a simple, fast, low cost, reliable and portable sample preparation technique that minimizes solvent consumption.Results:The use of home-made fibers is popular in the last two decades since the selectivity can be tuned by changing the surface characteristics through chemical and electrochemical modifications. Latter technique is preferred since the electroactive polymers can be coated onto the fiber under controlled electrochemical conditions and the film thicknesses can be adjusted by simply changing the deposition parameters. Thermal resistance and mechanical strength can be readily increased by incorporating different dopant ions into the polymeric structure and selectivity can be tuned by inserting functional groups and nanostructures. A vast number of analytes with wide range of polarities extracted by this means can be determined with a suitable chromatographic detector coupled to the system. Therefore, the main task is to improve the physicochemical properties of the fiber along with the extraction efficiency and selectivity towards the various analytes by adjusting the electrochemical preparation conditions.Conclusion:This review covers the fine tuning conditions practiced in electrochemical preparation of SPME fibers and in-tube systems and their applications in environmental, food and clinical analysis.
Collapse
Affiliation(s)
- Levent Pelit
- Department of Chemistry, Science Faculty, Ege University, Bornova, 35 100, İzmir, Turkey
| | - Füsun Pelit
- Department of Chemistry, Science Faculty, Ege University, Bornova, 35 100, İzmir, Turkey
| | - Hasan Ertaş
- Department of Chemistry, Science Faculty, Ege University, Bornova, 35 100, İzmir, Turkey
| | - Fatma Nil Ertaş
- Department of Chemistry, Science Faculty, Ege University, Bornova, 35 100, İzmir, Turkey
| |
Collapse
|
14
|
Ghiasvand A, Behfar M, Yazdankhah F. Reduced-Pressure Fiber-in-Needle Sampling of Aldehydes for Room Temperature Assessment of Edible Oils’ Oxidative Stability. Chromatographia 2019. [DOI: 10.1007/s10337-019-03752-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
15
|
Simultaneous HPLC-MS determination of 8-hydroxy-2'-deoxyguanosine, 3-hydroxyphenanthrene and 1-hydroxypyrene after online in-tube solid phase microextraction using a graphene oxide/poly(3,4-ethylenedioxythiophene)/polypyrrole composite. Mikrochim Acta 2019; 186:300. [PMID: 31025201 DOI: 10.1007/s00604-019-3429-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 04/10/2019] [Indexed: 12/30/2022]
Abstract
The exploration of monohydroxy polycyclic aromatic hydrocarbons and 8-hydroxy-2'-deoxyguanosine (8-OHdG) produced by oxidative stress and DNA damage is a powerful and non-invasive tool to study the health risk of exposure to polycyclic aromatic hydrocarbons (PAHs). A nanocomposite prepared from graphene oxide, poly(3,4-ethylenedioxythiophene) and polypyrrole was electrodeposited on the internal surface of a stainless-steel tube for online in-tube solid phase microextraction (IT-SPME) of 8-OHdG, 3-hydroxyphenanthrene and 1-hydroxypyrene from urine. The coating possesses excellent chemical and mechanical stability, high extraction efficiency, good resistance to matrix interference, and a long lifespan. An online IT-SPME-high performance liquid chromatography-mass spectrometry method was developed for the determination of these three metabolite biomarkers in human urine. Figures of merit include (a) enrichment factors of 30-48; (b) low limits of detection (4-41 pg·mL-1 at S/N = 3); (c) wide linear ranges (0.05-50 ng·mL-1); (d) good recoveries from spiked samples (71.6-109.5%); and (e) acceptable repeatability (2.3-14.6%). The method offers the advantages of low cost, simplicity, sensitivity, rapidity and automation. Graphical abstract Schematic illustration of online in-tube solid phase microextraction using graphene oxide/poly(3,4-ethylenedioxythiophene)/polypyrrole composites as adsorbent in a stainless-steel (SS) tube for the enrichment and simultaneous determination of 8-hydroxy-2'-deoxyguanosine, 3-hydroxyphenanthrene and 1-hydroxypyrene prior to HPLC-MS analysis.
Collapse
|
16
|
Current direction and advances in analytical sample extraction techniques for drugs with special emphasis on bioanalysis. Bioanalysis 2019; 11:313-332. [PMID: 30663327 DOI: 10.4155/bio-2018-0144] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Analytical techniques may not be compatible or sufficiently sensitive to the analytes, unless it undergoes a specific sample extraction procedure. Sample extraction can be considered as one of the key steps in analysis. Analysis of a poorly treated sample may produce inferior quality of analytical data. Continuous advancement and development of newer sample extraction techniques such as solid phase microextraction, ultrasound, magnetically and microwave assisted magnetic extraction; electro-membrane extraction and dried blood spotting are to address the shortcomings of the existing techniques and to provide more automation, minimizing preparation time and make them high throughput. This review summarizes the suitability of application of the advanced sample preparation techniques available for chemical and bioanalysis in a comprehensive manner. This review also provides a scientific guidance for selecting the appropriate sample extraction technique based on sample type.
Collapse
|
17
|
Iron oxide/silica/polypyrrole nanocomposite sorbent for the comparison study of direct-immersion and headspace solid-phase microextraction of aldehyde biomarkers in human urine. J Pharm Biomed Anal 2018; 159:37-44. [DOI: 10.1016/j.jpba.2018.06.052] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2018] [Revised: 05/25/2018] [Accepted: 06/25/2018] [Indexed: 11/17/2022]
|
18
|
Comparison of the Conventional and Electroenhanced Direct-Immersion Solid-Phase Microextraction for Sampling of Nicotine in Biological Fluids of the Human Body. Molecules 2018; 23:molecules23051171. [PMID: 29757971 PMCID: PMC6099498 DOI: 10.3390/molecules23051171] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Revised: 04/30/2018] [Accepted: 05/09/2018] [Indexed: 12/19/2022] Open
Abstract
A stainless steel fiber was made porous and adhesive by platinization and then coated by nanostructured polypyrrole (PPy), using an appropriate electrophoretic deposition (EPD) method. The morphological surface structure and functional groups of the PPy-coated fiber were studied using SEM (Scanning electron microscope) instrument. The prepared fiber was used for comparison of direct immersion (DI) and electroenhanced direct immersion solid-phase microextraction (EE-DI-SPME) of nicotine in human plasma and urine samples followed by gas chromatography flame ionization detector (GC-FID) determination. The effects of the influential experimental parameters on the efficiency of the DI-SPME and EE-DI-SPME methods, including the pH and ionic strength of the sample solution, applied Direct current (DC) voltage, extraction temperature and time and stirring rate, were optimized. Under the optimal conditions, the calibration curves for the DI-SPME-GC-FID and EE-DI-SPME-GC-FID methods were linear over the ranges of 0.1⁻10.0 μg mL-1 and 0.001⁻10.0 μg mL-1, respectively. The relative standard deviations (RSDs, n = 6) were found to be 6.1% and 4.6% for the DI and EE strategies, respectively. The LODs (limit of detection) of the DI-SPME-GC-FID and EE-DI-SPME-GC-FID methods were found to be 10 and 0.3 ng mL-1, respectively. The relative recovery values (for the analysis of 1 µg mL-1 nicotine) were found to be 91⁻110% for EE-DI-SPME and 75⁻105% for DI-SPME. The enrichment factors for DI-SPME and EE-DI-SPME sampling were obtained as 38,734 and 50,597, respectively. The results indicated that EE-SPME was more efficient for quantitation of nicotine in biological fluids. The developed procedure was successfully carried out for the extraction and measurement of nicotine in real plasma and urine samples.
Collapse
|
19
|
A modified multiscale peak alignment method combined with trilinear decomposition to study the volatile/heat-labile components in Ligusticum chuanxiong Hort - Cyperus rotundus rhizomes by HS-SPME-GC/MS. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1079:41-50. [DOI: 10.1016/j.jchromb.2018.01.040] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2017] [Revised: 01/30/2018] [Accepted: 01/31/2018] [Indexed: 12/16/2022]
|
20
|
Ghiasvand A, Koonani S, Yazdankhah F, Farhadi S. A comparison study on a sulfonated graphene-polyaniline nanocomposite coated fiber for analysis of nicotine in solid samples through the traditional and vacuum-assisted HS-SPME. J Pharm Biomed Anal 2018; 149:271-277. [PMID: 29128827 DOI: 10.1016/j.jpba.2017.11.020] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2017] [Revised: 11/04/2017] [Accepted: 11/05/2017] [Indexed: 01/27/2023]
Abstract
A simple, rapid, and reliable headspace solid-phase microextraction (HS-SPME) procedure, reinforced by applying vacuum in the extraction vial, was developed. It was applied for the extraction of nicotine in solid samples prior to determination by gas chromatography-flame ionization detection (GC-FID). First, the surface of a narrow stainless steel wire was made porous and adhesive by platinization to obtain a durable, higher surface area, and resistant fiber. Then, a thin film of sulfonated graphene/polyaniline (Sulf-G/PANI) nanocomposite was synthesized and simultaneously coated on the platinized fiber using the electrophoretic deposition (EPD) method. It was demonstrated that the extraction efficiency remarkably increased by applying the reduced-pressure condition in the extraction vial. To evaluate the conventional HS-SPME and vacuum-assisted HS-SPME (VA-HS-SPME) platforms, all experimental parameters affecting the extraction efficiency including desorption time and temperature, extraction time and temperature and moisture content of sample matrix were optimized. The highest extraction efficiency was obtained at 60°C, 10min (extraction temperature and time) and 280°C, 2min (desorption condition), for VA-HS-SPME strategy, while for conventional HS-SPME the extraction and desorption conditions found to be 100°C, 30min and 280°C, 2min, respectively. The Sulf-G/PANI coated fiber showed high thermal stability, good chemical/mechanical resistance, and long lifetime. For analysis of nicotine in solid samples using VA-HS-SPME-GC-FID, linear dynamic range (LDR) was 0.01-30μgg-1 (R2=0.996), the relative standard deviation (RSD%, n=6), for analyses of 1μgg-1 nicotine was calculated 3.4% and limit of detection (LOD) found to be 0.002μgg-1. The VA-HS-SPME-GC-FID strategy was successfully carried out for quantitation of nicotine in hair and tobacco real samples.
Collapse
Affiliation(s)
| | - Samira Koonani
- Department of Chemistry, Lorestan University, Khoramabad, Iran
| | | | - Saeid Farhadi
- Department of Chemistry, Lorestan University, Khoramabad, Iran
| |
Collapse
|