1
|
Yamamoto M, Hiraoka A, Yoshida T, Kishimoto S, Chikazawa G, Yoshitaka H. Recovery rate from conduction disorders in patients with permanent pacemaker implantation after transcatheter aortic valve implantation. Open Heart 2024; 11:e002867. [PMID: 39299736 PMCID: PMC11418474 DOI: 10.1136/openhrt-2024-002867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2024] [Accepted: 08/28/2024] [Indexed: 09/22/2024] Open
Abstract
BACKGROUNDS Permanent pacemaker implantation (PPMI) is one of the greatest disadvantages of transcatheter aortic valve implantation (TAVI). To seek the predictors and clinical impacts of PPMI and investigate the recovery rate from conduction disorders. METHODS We retrospectively analysed data from 745 consecutive patients who underwent TAVI for severe aortic stenosis from November 2013 to July 2022. The ventricular pacing (VP) rate was recorded at 1 and 6 months after PPMI and the recovery from conduction disorders was defined as the VP rate <1%. RESULTS Postoperative PPMI was performed in 7.1% (53/745) of patients. Balloon predilatation was significantly frequent in the PPMI (-) group (52.8% (28/53) vs 80.6% (558/692); p<0.001) and the oversizing ratio was significantly greater in the PPMI (+) group (11.8%±10.1% vs 9.1%±9.7%; p=0.035). Freedom from rehospitalisation due to heart failure rate was significantly higher in the PPMI (-) group (p=0.032). In patients with postoperative PPMI, recovery from conduction disorders was observed in 17.0% and 27.9% of patients at 1 and 6 months, respectively. CONCLUSIONS Recovery from conduction disorders occurred frequently. Avoidance of oversizing and extension of observation time may reduce the need for PPMI after TAVI.
Collapse
Affiliation(s)
- Maria Yamamoto
- Department of Cardiovascular Surgery, The Sakakibara Heart Institute, Okayama, Japan
| | - Arudo Hiraoka
- Department of Cardiovascular Surgery, The Sakakibara Heart Institute, Okayama, Japan
| | - Toshinobu Yoshida
- Department of Cardiology, The Sakakibara Heart Institute, Okayama, Japan
| | - Satoru Kishimoto
- Department of Cardiovascular Surgery, The Sakakibara Heart Institute, Okayama, Japan
| | - Genta Chikazawa
- Department of Cardiovascular Surgery, The Sakakibara Heart Institute, Okayama, Japan
| | - Hidenori Yoshitaka
- Department of Cardiovascular Surgery, The Sakakibara Heart Institute, Okayama, Japan
| |
Collapse
|
2
|
Sandhu A, Tzou WS. A Disruptive Technology: Determining Need for Permanent Pacing After TAVR. Curr Cardiol Rep 2021; 23:53. [PMID: 33871728 DOI: 10.1007/s11886-021-01481-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 02/17/2021] [Indexed: 12/01/2022]
Abstract
PURPOSE OF REVIEW Transcatheter aortic valve replacement (TAVR) has changed the paradigm for management of severe aortic stenosis. Despite evolution of TAVR over the past 2 decades, conduction system disturbances remain a concern post-TAVR. In this review, we describe (1) permanent pacemaker (PP) implant rates associated with TAVR, (2) risk factors predicting need for PP therapy post-TAVR, (3) management of perioperative conduction abnormalities, and (4) novel areas of research. RECENT FINDINGS Conduction disturbances remain a common issue post-TAVR, in particular, left bundle branch block (LBBB). Though newer data describes resolution of a significant fraction of these disturbances over time, rates of pacemaker therapy remain high despite improvements in valve technology and procedural technique. Recent consensus statements and guideline documents are important first steps in standardizing an approach to post-TAVR conduction disturbances. New areas of research show promise in both prediction and treatment of conduction disturbances post-TAVR.
Collapse
Affiliation(s)
- Amneet Sandhu
- Division of Cardiology, Cardiac Electrophysiology Section, University of Colorado School of Medicine, Anschutz Medical Campus, Aurora, CO, 80045, USA.,Division of Cardiology, Denver VA Medical Center, Denver, CO, USA
| | - Wendy S Tzou
- Division of Cardiology, Cardiac Electrophysiology Section, University of Colorado School of Medicine, Anschutz Medical Campus, Aurora, CO, 80045, USA.
| |
Collapse
|
3
|
Aalaei-Andabili SH, Beaver TM, Bavry AA, Petersen JW, Karimi A, Wayangankar S, Arnaoutakis G, Anderson RD. Outcomes of Direct Transcatheter Aortic Valve Replacement Without Balloon Aortic Valvuloplasty Using a New Generation Valve. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2019; 20:1100-1104. [PMID: 30826204 DOI: 10.1016/j.carrev.2019.01.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2018] [Revised: 12/28/2018] [Accepted: 01/14/2019] [Indexed: 01/21/2023]
Abstract
PURPOSE We investigated the outcomes of patients who underwent Transcatheter Aortic Valve Replacement (TAVR) with and without Balloon Aortic Valvuloplasty (BAV) using the SAPIEN 3 (S3) valve. METHODS All patients who underwent TAVR using S3 valve were included. The primary outcomes were the incidence of stroke and significant paravalvular leak (PVL). Secondary outcomes were the incidence of mortality, balloon post dilation, and need for permanent pacemaker. RESULTS From July-2014 to April-2018, 34 (9%) patients underwent BAV prior to TAVR and 344 (91%) patients underwent direct TAVR without BAV using the S3 valve. The Society of Thoracic Surgeons (STS) risk score was similar between two groups; 5.8 ± 3.5 in no BAV group and 5.4 ± 3.3 in BAV group, p = 0.53. After TAVR, 6 (1.7%) patients in no BAV group but no patient in BAV group developed stroke (p = 1.0). No patient had severe PVL and only 5 patients (1.3%) had moderate PVL at 30-day; 4 (1.2%) in no BAV group and 1 (2.9%) in BAV group (p = 0.38). Forty-six patients (13.4%) in the no BAV group and 4 (11.8%) patients in the BAV group needed balloon post dilation (p = 1.0). Six (1.6%) patients died during hospitalization, all in the no BAV group (p = 1.0). Forty-five (11.9%) patients needed new pacemaker implantation; 44 (12.8%) patients in no BAV group and 1 (2.9%) patient in BAV group (p = 0.1). Two-year survival rate was 85% in no BAV group and 84% in BAV group (p = 0.46). CONCLUSIONS TAVR using S3 valves is associated with very low rates of post-TAVR stroke and significant PVL. Outcomes of direct TAVR are similar to the outcomes of TAVR with BAV, without an increased rate of stroke, significant PVL, or balloon post dilation.
Collapse
Affiliation(s)
- Seyed Hossein Aalaei-Andabili
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, University of Florida, Gainesville, FL, USA; Division of Cardiology, Department of Medicine, University of Florida, Gainesville, FL, USA
| | - Thomas M Beaver
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, University of Florida, Gainesville, FL, USA
| | - Anthony A Bavry
- Division of Cardiology, Department of Medicine, University of Florida, Gainesville, FL, USA; North Florida/South Georgia Veterans Health System, Gainesville, FL, USA
| | - John W Petersen
- Division of Cardiology, Department of Medicine, University of Florida, Gainesville, FL, USA
| | - Ashkan Karimi
- Division of Cardiology, Department of Medicine, University of Florida, Gainesville, FL, USA
| | - Siddharth Wayangankar
- Division of Cardiology, Department of Medicine, University of Florida, Gainesville, FL, USA
| | - George Arnaoutakis
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, University of Florida, Gainesville, FL, USA
| | - R David Anderson
- Division of Cardiology, Department of Medicine, University of Florida, Gainesville, FL, USA.
| |
Collapse
|