OBJECTIVE
The study aimed to compare the effectiveness of drug-coated balloon (DCB) and drug-eluting stents (DESs) to standard endovascular techniques like percutaneous transluminal angioplasty (PTA) and bare metal stent (BMS) for treating infrapopliteal artery disease.
METHODS
Including 8 DCB trials and 4 DES trials, this meta-analysis of 12 recent randomized controlled trials (RCTs) is comprehensive. We searched MEDLINE, EMBASE, Science of Web, Cochrane, and PubMed for this meta-analysis. We searched these databases for papers from their inception to February 2023. We also analyzed the references given in the listed studies and any future study that cited them. No language or publication date restrictions were applied to the 12 RCTs. The experimental group includes 8 DCB studies and 4 DES investigations, the DCB group is primarily concerned with the paclitaxel devices, whereas the DES group is preoccupied with the "-limus" devices. Key clinical outcomes in this study were primary patency and binary restenosis rates. This study's secondary outcomes are late lumen loss (LLL), clinically-driven target lesion revascularization (CD-TLR), limb amputation, and all-cause mortality. The evidence quality was assessed using Cochrane risk-of-bias. The PROSPERO registration number for this study is CRD42023462038.
FINDINGS
Only 108 of 1152 publications found satisfied qualifying criteria and contained data. All 13 RCTs have low to moderate bias. Drug-coated balloons and DESs were compared in the excluded study. The analysis comprised 2055 participants from 12 RCTs that met the inclusion criteria, including 1417 DCB patients and 638 DES patients. Drug-coated balloons outperform traditional methods in short-term monitoring of primary patency, binary restenosis, and CD-TLR. The benefits fade over time, and the 2 techniques had similar major amputation rates, mortality rates, and LLL. Drug-eluting stents outperform conventional procedures in primary patency, binary restenosis, and CD-TLR during medium-term to short-term follow-up. Comparing the 2 methods, major and minor amputations, death rate, and LLL were similar.
CONCLUSION
Comparison of DES and DCB with PTA or BMS shows that DES had better follow-up results. DCB has positive short-term results, but long-term effects differ, however, more research is needed to determine when DES and DCB should be used in medical procedures.
CLINICAL IMPACT
The provision of additional evidence to substantiate the advancement of drug-coated balloon (DCB) therapy in the treatment of lower limb arteriosclerosis obliterans, particularly in the below-the-knee area characterized by high calcium load and significant occlusion, is comparable in efficacy to conventional procedures. This finding is advantageous for the progress of interventional revascularization. The advancement and efficacy of DCB have resulted in improved treatment outcomes for medical practitioners in clinical settings. Our research incorporates the most recent randomized experiments.