1
|
Du J, Yang L, Hao Z, Li H, Yang C, Wang X, Zhang Z, Du Y, Zhang Y. Development and validation of a nomogram for major adverse cardiovascular events after chronic total occlusion percutaneous coronary intervention for ischemic heart failure. Catheter Cardiovasc Interv 2024. [PMID: 39033330 DOI: 10.1002/ccd.31139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 02/21/2024] [Accepted: 06/18/2024] [Indexed: 07/23/2024]
Abstract
BACKGROUND Chronic total occlusion percutaneous coronary intervention (CTO-PCI) is an available means of revascularization in patients with ischemic heart failure (IHF). However, the prognosis of IHF patients undergoing CTO-PCI remains unclear due to the lack of reliable clinical predictive tools. AIM This study aimed to establish a nomogram for major adverse cardiovascular events (MACE) after CTO-PCI in IHF patients. METHODS Sixty-seven potential predictive variables for MACE in 560 IHF patients undergoing CTO-PCI were screened using least absolute shrinkage and selection operator regression. A nomogram was constructed based on multivariable Cox regression to visualize the risk of MACE, and then evaluation was carried out using the concordance index (C-index), time-independent receiver operating characteristic (timeROC) curves, calibration curves, and decision curve analysis (DCA). RESULTS During a median follow-up of 32.0 months, there were 208 MACE occurrences. Seven variables were selected for nomogram construction: age, left ventricular ejection fraction, left ventricular end-diastolic diameter, N-terminal precursor B-type diuretic peptide, bending, and use of intravascular ultrasound and beta-blockers. The C-index was 0.715 (0.680-0.750) and the internal validation result was 0.715 (0.676-0.748). The timeROC area under the curve at 6 months, 1 year, and 2 years was 0.750 (0.653-0.846), 0.747 (0.690-0.804), and 0.753 (0.708-0.798), respectively. The calibration curves and DCA showed the nomogram had acceptable calibration and clinical applicability. CONCLUSIONS We developed a simple and efficient nomogram for MACE after CTO-PCI in IHF patients, which helps in early risk stratification and postoperative management optimization.
Collapse
Affiliation(s)
- Jiaqi Du
- Department of Cardiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Lulu Yang
- Department of Cardiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Zhengyang Hao
- Department of Cardiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Huan Li
- Department of Cardiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Chunlei Yang
- Department of Cardiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Xing Wang
- Department of Cardiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Zhaozhi Zhang
- Department of Cardiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Youyou Du
- Department of Cardiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Yanzhou Zhang
- Department of Cardiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| |
Collapse
|
2
|
Tanaka K, Okamura A, Yoshikawa R, Tsuchikane E, Ishikawa M, Suzuki S, Nagai H, Sumiyoshi A, Kawahira M, Yamasaki T, Matsuda H, Iwamoto M, Watanabe S, Yamasaki K, Tanaka N, Koyama Y, Iwanaga Y, Watanabe H. Tip Detection-Antegrade Dissection and Re-Entry With New Puncture Wire in CTO Intervention: Revolution Through 3D-Wiring. JACC. ASIA 2024; 4:359-372. [PMID: 38765666 PMCID: PMC11099825 DOI: 10.1016/j.jacasi.2023.11.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 11/20/2023] [Accepted: 11/29/2023] [Indexed: 05/22/2024]
Abstract
Background The authors devised the tip detection (TD) method and developed AnteOwl WR intravascular ultrasound to standardize intravascular ultrasound-based 3-dimensional wiring for intraplaque tracking in chronic total occlusion (CTO)-percutaneous coronary intervention (PCI). The TD method also allowed antegrade dissection and re-entry (ADR). Combining TD-ADR with Conquest Pro 12 Sharpened Tip (CP12ST) wire, a new ADR wire with the strongest penetration force developed to date, enabled re-entry anywhere except calcification sites. Objectives This study investigated the efficacy and feasibility of TD-ADR by comparison of procedural outcomes with Stingray-ADR in CTO-PCI. Methods Twenty-seven consecutive CTO cases treated by TD-ADR with CP12ST wire between August 2021 and April 2023 and 27 consecutive CTO cases treated by Stingray-ADR with Conquest 8-20 (CP20) wire between March 2018 and July 2021 were retrospectively enrolled as the TD-ADR by CP12ST wire group and Stingray-ADR by CP20 wire group, respectively, from 4 facilities that could share technical information on these procedures. Results The success rate of the ADR procedure was significantly improved (27 of 27 cases [100%] vs 18 of 27 cases [67%], respectively; P = 0.002) and total procedural time was significantly reduced (median procedural time: 145.0 [Q1-Q3: 118.0-240.0] minutes vs 185.0 [Q1-Q3: 159.5-248.0] minutes, respectively; P = 0.028) in the TD-ADR by CP12ST wire group compared to the Stingray-ADR by CP20 wire group. There were few in-hospital major adverse cardiac and cerebrovascular events or no complications in either group. Conclusions TD-ADR by CP12ST wire can standardize highly accurate ADR in CTO-PCI.
Collapse
Affiliation(s)
- Kota Tanaka
- Cardiovascular Center, Sakurabashi Watanabe Hospital, Osaka, Japan
| | - Atsunori Okamura
- Cardiovascular Center, Sakurabashi Watanabe Hospital, Osaka, Japan
| | | | - Etsuo Tsuchikane
- Department of Cardiovascular Medicine, Toyohashi Heart Center, Toyohashi, Japan
| | - Masato Ishikawa
- Department of Cardiology, Fujita Health University, Aichi, Japan
| | | | | | | | | | | | - Hiroaki Matsuda
- Department of Cardiovascular Medicine, Nagoya Heart Center, Nagoya, Japan
| | - Mutsumi Iwamoto
- Cardiovascular Center, Sakurabashi Watanabe Hospital, Osaka, Japan
| | - Satoshi Watanabe
- Cardiovascular Center, Sakurabashi Watanabe Hospital, Osaka, Japan
| | - Keita Yamasaki
- Cardiovascular Center, Sakurabashi Watanabe Hospital, Osaka, Japan
| | - Nobuaki Tanaka
- Cardiovascular Center, Sakurabashi Watanabe Hospital, Osaka, Japan
| | - Yasushi Koyama
- Cardiovascular Center, Sakurabashi Watanabe Hospital, Osaka, Japan
| | | | - Heitaro Watanabe
- Cardiovascular Center, Sakurabashi Watanabe Hospital, Osaka, Japan
| |
Collapse
|
3
|
Suzuki S, Okamura A, Nagai H, Ishikawa M, Kameda S, Tanaka K, Watanabe H, Nakazawa G, Sakata Y, Shiojima I. Efficacy of Intravascular Ultrasound-Based 3D Wiring Using the Tip Detection Method for CTO Intervention. JACC. ASIA 2023; 3:526-530. [PMID: 37396423 PMCID: PMC10308111 DOI: 10.1016/j.jacasi.2023.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 03/01/2023] [Accepted: 03/06/2023] [Indexed: 07/04/2023]
Abstract
To perform intravascular ultrasound (IVUS)-based real-time 3-dimensional wiring in chronic total occlusion percutaneous coronary intervention, we devised a tip detection method and developed AnteOwl WR (AO)-IVUS, which is an upgraded version of Navifocus WR (Navi)-IVUS with an added pull back transducer system. We compared the procedural outcomes of AO-IVUS-based 3-dimensional wiring using the tip detection method (n = 30) and Navi-IVUS-based conventional wiring (n = 17) in chronic total occlusion percutaneous coronary intervention. The success rate of IVUS-guided wiring was markedly improved in the AO-IVUS group compared with the Navi-IVUS group (93% vs 59% of cases, respectively; P = 0.007). In cases of successful IVUS-guided wiring, the IVUS-guided wiring time was markedly improved in the AO-IVUS group compared with the Navi-IVUS group (9 ± 8 minutes vs 24 ± 26 minutes, respectively; P = 0.001). There were 2 successful cases of tip detection-antegrade dissection and re-entry in the AO-IVUS group.
Collapse
Affiliation(s)
- Satoshi Suzuki
- Cardiovascular Center, Sakurabashi Watanabe Hospital, Osaka, Japan
| | - Atsunori Okamura
- Cardiovascular Center, Sakurabashi Watanabe Hospital, Osaka, Japan
| | - Hiroyuki Nagai
- Cardiovascular Center, Sakurabashi Watanabe Hospital, Osaka, Japan
| | - Masato Ishikawa
- Department of Cardiology, Fujita Health University, Aichi, Japan
| | - Satoshi Kameda
- Division of Cardiology, Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Kota Tanaka
- Cardiovascular Center, Sakurabashi Watanabe Hospital, Osaka, Japan
| | - Heitaro Watanabe
- Cardiovascular Center, Sakurabashi Watanabe Hospital, Osaka, Japan
| | - Gaku Nakazawa
- Division of Cardiology, Kindai University Faculty of Medicine, Osaka, Japan
| | - Yasushi Sakata
- Division of Cardiology, Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Ichiro Shiojima
- Department of Medicine II, Kansai Medical University, Osaka, Japan
| |
Collapse
|
4
|
Suzuki S, Okamura A, Nagai H, Iwakura K. Tip detection-antegrade dissection and reentry using intravascular ultrasound in chronic total occlusion intervention: first human case report. Eur Heart J Case Rep 2022; 6:ytac233. [PMID: 35757584 PMCID: PMC9214776 DOI: 10.1093/ehjcr/ytac233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 02/03/2022] [Accepted: 06/06/2022] [Indexed: 11/13/2022]
Abstract
Abstract
Background
It has been considered impossible to perform antegrade dissection and reentry (ADR) by simply puncturing with a guidewire using the intravascular ultrasound (IVUS) observation without the support of the Stingray system.
Case summary
A 78-year-old man suffered from effort angina pectoris due to a chronic total occlusion (CTO) lesion in the left circumflex coronary artery. A retry percutaneous coronary intervention for the CTO lesion was attempted at our hospital. The J-CTO score was 3. The first guidewire entered the subintimal space. We moved onto Stingray-ADR using the angiographic observation, but the guidewire could not be led into the true lumen. AnteOwl WR-IVUS (AO-IVUS) observation revealed a distal true lumen in which the inner lumen was maintained 5 mm beyond the CTO exit. We decided to perform the tip detection-ADR using the AO-IVUS observation. The tip detection method allowed the tip of the penetration wire to puncture the wall between the subintima and the true lumen in an exactly vertical direction, resulting in the successful creation of a reentry point. The CTO lesion was dilated with one drug-eluting stent, and normal antegrade blood flow was achieved.
Discussion
Since the tip detection method enables accurate punctures, it may allow for ADR by simply puncturing using a guidewire. Due to this method being performed using the IVUS observation, it is likely more reliable than Stingray-ADR using the angiographic observation.
Collapse
Affiliation(s)
- Satoshi Suzuki
- Cardiovascular Center, Sakurabashi Watanabe Hospital, 2-4-32 Umeda, Kita-ku , Osaka 530-0001, Japan
| | - Atsunori Okamura
- Cardiovascular Center, Sakurabashi Watanabe Hospital, 2-4-32 Umeda, Kita-ku , Osaka 530-0001, Japan
| | - Hiroyuki Nagai
- Cardiovascular Center, Sakurabashi Watanabe Hospital, 2-4-32 Umeda, Kita-ku , Osaka 530-0001, Japan
| | - Katsuomi Iwakura
- Cardiovascular Center, Sakurabashi Watanabe Hospital, 2-4-32 Umeda, Kita-ku , Osaka 530-0001, Japan
| |
Collapse
|