1
|
Epstein RH, Nemes R, Renew JR, Brull SJ. Area under the curve and amplitude of the compound motor action potential are clinically interchangeable quantitative measures of neuromuscular block: a method comparison study. BJA OPEN 2024; 11:100293. [PMID: 38974718 PMCID: PMC11226963 DOI: 10.1016/j.bjao.2024.100293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2024] [Accepted: 05/22/2024] [Indexed: 07/09/2024]
Abstract
Background Current guidelines recommend quantitative neuromuscular block monitoring during neuromuscular blocking agent administration. Monitors using surface electromyography (EMG) determine compound motor action potential (cMAP) amplitude or area under the curve (AUC). Rigorous evaluation of the interchangeability of these methods is lacking but necessary for clinical and research assurance that EMG interpretations of the depth of neuromuscular block are not affected by the methodology. Methods Digitised EMG waveforms were studied from 48 patients given rocuronium during two published studies. The EMG amplitudes and AUCs were calculated pairwise from all cMAPs classified as valid by visual inspection. Ratios of the first twitch (T1) to the control T1 before administration of rocuronium (T1c) and train-of-four ratios (TOFRs) were compared using repeated measures Bland-Altman analysis. Results Among the 2419 paired T1/T1c differences where the average T1/T1c was ≤0.2, eight (0.33%) were outside prespecified clinical limits of agreement (-0.148 to 0.164). Among the 1781 paired TOFR differences where the average TOFR was ≥0.8, 70 (3.93%) were outside the prespecified clinical limits of agreement ((-0.109 to 0.134). Among all 7286 T1/T1c paired differences, the mean bias was 0.32 (95% confidence interval 0.202-0.043), and among all 5559 paired TOFR differences, the mean bias was 0.011 (95% confidence interval 0.0050-0.017). Among paired T1/T1c and TOFR differences, Lin's concordance correlation coefficients were 0.98 and 0.995, respectively. Repeatability coefficients for T1/T1c and TOFR were <0.08, with no differences between methods. Conclusions Quantitative assessment neuromuscular block depth is clinically interchangeable when calculated using cMAP amplitude or the AUC.
Collapse
Affiliation(s)
- Richard H. Epstein
- Department of Anesthesiology, Perioperative Medicine & Pain Management, University of Miami, Miller School of Medicine, Miami, FL, USA
| | - Réka Nemes
- Department of Anesthesiology and Intensive Care, University of Debrecen, Debrecen, Hungary
| | - Johnathan R. Renew
- Department of Anesthesiology and Perioperative Medicine, Mayo Clinic College of Medicine and Science, Jacksonville, FL, USA
| | - Sorin J. Brull
- Department of Anesthesiology and Perioperative Medicine, Mayo Clinic College of Medicine and Science, Jacksonville, FL, USA
| |
Collapse
|
2
|
Dong Y, Guo W, Yang Y, Li Q. The Effect of Phonomyography Prototype for Intraoperative Neuromuscular Monitoring: A Preliminary Study. Bioengineering (Basel) 2024; 11:486. [PMID: 38790354 PMCID: PMC11117765 DOI: 10.3390/bioengineering11050486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2024] [Revised: 04/29/2024] [Accepted: 05/10/2024] [Indexed: 05/26/2024] Open
Abstract
Quantitative neuromuscular monitoring, as extolled by clinical guidelines, is advocated to circumvent the complications associated with neuromuscular blockers (NMBs), such as residual neuromuscular block (rNMB). Nonetheless, the worldwide utilization of such methods remains undesirable. Phonomyography (PMG) boasts the advantages of convenience, stability, and multi-muscle recording which may be a promising monitoring method. The purpose of this preliminary study is conducting a feasibility analysis and an effectiveness evaluation of a PMG prototype under general anesthesia. A prospective observational preliminary study was conducted. Twenty-five adults who had undergone none-cardiac elective surgery were enrolled. The PMG prototype and TOF-Watch SX simultaneously recorded the pharmacodynamic properties of single bolus rocuronium at the ipsilateral adductor pollicis for each patient. For the primary outcome, the time duration to 0.9 TOF ratio of the two devices reached no statistical significance (p > 0.05). For secondary outcomes, the multi-temporal neuromuscular-monitoring measurements between the two devices also reached no statistical significance (p > 0.05). What is more, both the Spearman's and Pearson's correlation tests revealed a strong correlation across all monitoring periods between the PMG prototype and TOF-Watch SX. Additionally, Bland-Altman plots demonstrated a good agreement between the two devices. Thus, the PMG prototype was a feasible, secure, and effective neuromuscular-monitoring technique during general anesthesia and was interchangeable with TOF-Watch SX.
Collapse
Affiliation(s)
- Yanjie Dong
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu 610041, China;
| | - Weichao Guo
- Meta Robotics Institute, Shanghai Jiao Tong University, Shanghai 200240, China;
| | - Yi Yang
- Department of Anesthesiology, Sichuan Provincial People’s Hospital, Chengdu 610072, China;
| | - Qian Li
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu 610041, China;
| |
Collapse
|
3
|
Makino M, Kaneko S, Sato S, Kawazoe Y, Ichinomiya T, Murata H, Yoshitomi O, Hara T. Effects of the attachment method of the stimulating electrodes Nihon-Kohden NM-345Y™ and changes in forearm position on stimulus current values during calibration in electromyography-based neuromuscular monitoring: a single-center experimental study. J Anesth 2023; 37:888-895. [PMID: 37653275 DOI: 10.1007/s00540-023-03250-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Accepted: 08/21/2023] [Indexed: 09/02/2023]
Abstract
PURPOSE The traditionally recommended method for attaching electromyography (EMG) electrodes (NM-345Y™) during EMG-based neuromuscular monitoring developed by Nihon-Kohden may decrease the monitoring accuracy when forearm limb position changes. This study investigated methods for attaching stimulating electrodes that maintained stable EMG-based neuromuscular monitoring accuracy, regardless of forearm limb position changes. METHODS This single-center experimental study recruited 28 healthy adults from October 2022 to December 2022. The NM-345Y™ was attached to the forearm using three patterns: Pattern N, electrodes attached according to the attachment pattern recommended by Nihon-Kohden; Pattern U, electrodes attached along the ulnar nerve identified using an ultrasound device; Pattern C, electrodes attached where the ulnar nerve crosses the line connecting the centers of the anode and cathode of the stimulating electrodes. The stimulus current values during calibration were measured at three forearm positions for each attachment pattern: supination 90 degrees; pronation 0 degrees; pronation 90 degrees. The differences in stimulus current values caused by forearm position changes were calculated as the difference between values at supination 90 degrees and pronation 0 degrees and between values at supination 90 degrees and pronation 90 degrees. RESULTS Pattern C showed significantly smaller differences than Pattern N between the stimulus current values at supination 90 degrees and pronation 0 degrees (p = 0.018) and between the stimulus current values at supination 90 degrees and pronation 90 degrees (p = 0.008). CONCLUSION Crossing the ulnar nerve with the line connecting the anode and cathode of the stimulating electrodes may stabilize EMG-based neuromuscular monitoring accuracy.
Collapse
Affiliation(s)
- Madoka Makino
- Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Shohei Kaneko
- Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
| | - Shuntaro Sato
- Clinical Research Center, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Yurika Kawazoe
- Clinical Research Center, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Taiga Ichinomiya
- Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Hiroaki Murata
- Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Osamu Yoshitomi
- Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Tetsuya Hara
- Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| |
Collapse
|
4
|
Liu X, Zhang X, Shang X, Wang H, Hou W, Sun Z. The TOFr of 0.75 to 0.85 is the optimal timing for IONM during thyroid surgery: a prospective observational cohort study. BMC Anesthesiol 2023; 23:286. [PMID: 37612707 PMCID: PMC10464378 DOI: 10.1186/s12871-023-02224-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Accepted: 07/28/2023] [Indexed: 08/25/2023] Open
Abstract
BACKGROUD Recurrent laryngeal nerve (RLN) injury is one of the serious complications of thyroid tumour surgery, surgical treatment of thyroid cancer requires careful consideration of the RLN and its impact on glottis function. There has been no unified standard for precise neuromuscular block monitoring to guide the monitoring of RLN in thyroid surgery. This study aimed to investigate the correlation between Train-of-four stabilization ratio (TOFr) and neural signal values of intraoperative neurophysiological monitoring (INOM) during thyroid operation, and further to determine the optimal timing for INOM during thyroid operation. METHODS Patients scheduled for thyroid tumour resection with INOM and RLN monitoring from April 2018 to July 2018 in our center were recruited. Electromyography (EMG) signals and corresponding TOFr were collected. All nerve stimulation data were included in group VR. Vagus nerve stimulation data were included in Subgroup V. RLN stimulation data were included in Subgroup R. The timing of recording was as follows: Vagus nerve EMG amplitude after opening the lateral space between the thyroid and carotid sheath and before the initiation of thyroid dissection, RLN EMG amplitude at first recognition, RLN EMG amplitude after complete thyroid dissection (Repeat three times), and Vagus nerve EMG amplitude after resection of the thyroid (Repeat three times). Correlation analysis of continuous variables was described by a scatter diagram. Pearson correlation analysis or Spearman correlation analysis was used for the two groups of variables. RESULTS Finally, 134 vagus nerve signals and 143 RLN signals were analysed after matching with TOFr. The EMG amplitude in the VR group and subgroups after nerve stimulation was positively correlated with TOFr (p < 0.05). In the VR, V and R group, the incidence of EMG ≥ 500 µV in the 0.75 < TOFr ≤ 0.85 interval was significantly higher than the 0 < TOFr ≤ 0.75 interval (P = 0.002, P = 0.013 and P = 0.029), and has no statistical difference compared to 0.85 < TOFr ≤ 0.95 interval (P > 0.05). CONCLUSIONS The EMG signals of the RLN and vagus nerve stimulation during thyroid surgery were positively correlated with TOFr. TOFr > 0.75 could reflect more than 50% of the effective nerve electrophysiological signals, 0.75 < TOFr ≤ 0.85 interval was the optimal timing for IONM during thyroid surgery. TRIAL REGISTRATION Chinese Clinical Trial Registry (ChiCTR1800015797) Registered on 20/04/2018. https://www.chictr.org.cn .
Collapse
Affiliation(s)
- Xi Liu
- Department of Anesthesiology and Intensive Care Unit, Fudan University Shanghai Cancer Center; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
- Department of Anaesthesiology, Shanghai Jiaotong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Xue Zhang
- Department of Anesthesiology and Intensive Care Unit, Fudan University Shanghai Cancer Center; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Xue Shang
- Department of Anesthesiology and Intensive Care Unit, Fudan University Shanghai Cancer Center; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Huihui Wang
- Department of Anesthesiology and Intensive Care Unit, Fudan University Shanghai Cancer Center; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China.
| | - Wenting Hou
- Department of Anesthesiology and Intensive Care Unit, Fudan University Shanghai Cancer Center; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China.
| | - Zhirong Sun
- Department of Anesthesiology and Intensive Care Unit, Fudan University Shanghai Cancer Center; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China.
| |
Collapse
|
5
|
Iwasaki H, Takahoko K, Matsui T, Takada Y, Takahashi Y, Sugawara A, Kurosawa A. The impact of electrosurgical devices on electromyography-based neuromuscular monitoring during abdominal laparotomy: a case series. J Clin Monit Comput 2023:10.1007/s10877-023-01039-9. [PMID: 37243953 DOI: 10.1007/s10877-023-01039-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Accepted: 05/20/2023] [Indexed: 05/29/2023]
Abstract
The present study aimed to evaluate the effect of electrosurgical devices on neuromuscular monitoring using an electromyography (EMG)-based neuromuscular monitor during abdominal laparotomy. Seventeen women (aged 32-64 years) undergoing gynecological laparotomy under total intravenous general anesthesia were enrolled in the study. A TetraGraph™ was placed to stimulate the ulnar nerve and to monitor the abductor digiti minimi muscle. After device calibration, train-of-four (TOF) measurements were repeated at intervals of 20 s. Rocuronium 0.6 to 0.9 mg/kg was administered for induction, and additional doses of 0.1 to 0.2 mg/kg were administered to maintain TOF counts ≤ 2 during the surgery. The primary outcome of the study was the ratio of measurement failure. The secondary outcomes of the study were the total number of measurements, the number of measurement failures, and the most extended consecutive number of measurement failures. The data are expressed as median (range). Of the 3091 (1480-8134) measurements, the number of measurement failures was 94 (60-200), resulting in a failure ratio of 3.5% (1.4-6.5%). The most extended consecutive number of measurement failures was 8 (4-13). All attending anesthesiologists were able to maintain and reverse neuromuscular blocks under EMG guidance. This prospective observational study demonstrated that the use of EMG-based neuromuscular monitoring does not seem to be heavily affected by electrical interference during lower abdominal laparotomic surgery. Trial registration This trial was registered in the University Hospital Medical Information Network under registration number UMIN000048138 (registration date; June 23, 2022).
Collapse
Affiliation(s)
- Hajime Iwasaki
- Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Midorigaoka-higashi 2-1-1-1, Asahikawa, Hokkaido, Japan.
| | - Kenichi Takahoko
- Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Midorigaoka-higashi 2-1-1-1, Asahikawa, Hokkaido, Japan
| | - Takuro Matsui
- Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Midorigaoka-higashi 2-1-1-1, Asahikawa, Hokkaido, Japan
| | - Yui Takada
- Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Midorigaoka-higashi 2-1-1-1, Asahikawa, Hokkaido, Japan
| | - Yukako Takahashi
- Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Midorigaoka-higashi 2-1-1-1, Asahikawa, Hokkaido, Japan
| | - Ami Sugawara
- Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Midorigaoka-higashi 2-1-1-1, Asahikawa, Hokkaido, Japan
| | - Atsushi Kurosawa
- Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Midorigaoka-higashi 2-1-1-1, Asahikawa, Hokkaido, Japan
| |
Collapse
|
6
|
Motamed C. Intraoperative Monitoring of Neuromuscular Blockade. Life (Basel) 2023; 13:life13051184. [PMID: 37240830 DOI: 10.3390/life13051184] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 05/10/2023] [Accepted: 05/13/2023] [Indexed: 05/28/2023] Open
Abstract
There is a global trend of new guidelines highly recommending quantitative neuromuscular monitoring in the operating room. In fact, it is almost certain that quantitatively monitoring the depth of intraoperative muscle paralysis may permit the rational use of muscle relaxants and avoid some of the major related complications, namely postoperative pulmonary complications. A specific culture related to this issue is necessary to integrate quantitative monitoring of muscle relaxants as part of a major monitoring entity in anesthetized patients. For this purpose, it is necessary to fully understand the physiology, pharmacology and concept of monitoring as well as the choice of pharmacological reversal, including the introduction of sugammadex a decade ago.
Collapse
Affiliation(s)
- Cyrus Motamed
- Institut de Cancérologie Gustave Roussy, 94080 Villejuif, France
| |
Collapse
|
7
|
Sato H, Iwasaki H, Doshu-Kajiura A, Katagiri S, Takagi S, Luthe SK, suzuki T. Comparison of two electromyography-based neuromuscular monitors, AF-201 P and TetraGraph, in rocuronium-induced neuromuscular block: a prospective comparative study. Anaesth Crit Care Pain Med 2022; 41:101145. [DOI: 10.1016/j.accpm.2022.101145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 07/13/2022] [Accepted: 07/25/2022] [Indexed: 12/01/2022]
|
8
|
Iwasaki H, Yamamoto M, Sato H, Doshu-Kajiura A, Kitajima O, Takagi S, Luthe SK, Suzuki T. A Comparison Between the Adductor Pollicis Muscle Using TOF-Watch SX and the Abductor Digiti Minimi Muscle Using TetraGraph in Rocuronium-Induced Neuromuscular Block: A Prospective Observational Study. Anesth Analg 2022; 135:370-375. [DOI: 10.1213/ane.0000000000005897] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|