Liu Z, Deng C, Zhao R, Xu G, Bai Z, Wang Z, Zhang W, Ma Y, Hu X, Jin C, Chen P, Ma S, Shi B. Association of LDL-C level with neoatherosclerosis and plaque vulnerability in patients with late restenosis: an optical coherence tomography study. Int J Cardiovasc Imaging 2023; 39:2609-2619. [PMID: 37804387 PMCID: PMC10691981 DOI: 10.1007/s10554-023-02956-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 09/10/2023] [Indexed: 10/09/2023]
Abstract
Neoatherosclerosis (NA) is a significant contributor to late stent failure; however, predictors of late in-stent restenosis (ISR) with NA have not been systematically reported. This study aimed to identify predictors of NA incidence and plaque vulnerability in patients with late ISR and the role of low-density lipoprotein cholesterol (LDL-C) levels in this process. A total of 216 patients with 216 lesions who underwent optical coherence tomography (OCT) before interventional procedure for late drug-eluting stent ISR were enrolled and divided into NA and non-NA groups based on OCT findings. Results showed that higher LDL-C levels were associated with NA, thin-cap fibroatheroma (TCFA), intimal disruption, plaque erosion, and thrombosis. Multivariate regression analysis revealed that the LDL-C level was an independent risk factor for NA and TCFA. The LDL-C levels exhibited a significant predictive value for NA and TCFA, surpassing other factors such as stent age and other lipid types. In conclusion, a high LDL-C level is an independent predictor of NA incidence and plaque vulnerability in patients with late ISR.
Collapse
Affiliation(s)
- Zhijiang Liu
- Department of Cardiology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, China
| | - Chancui Deng
- Department of Cardiology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, China
| | - Ranzun Zhao
- Department of Cardiology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, China
| | - Guanxue Xu
- Department of Cardiology, the Fifth Affiliated Hospital of Zunyi Medical University, Zhuhai, China
| | - Zhixun Bai
- Department of Cardiology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, China
| | - Zhenglong Wang
- Department of Cardiology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, China
| | - Wei Zhang
- Department of Cardiology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, China
| | - Yi Ma
- Department of Cardiology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, China
| | - Xingwei Hu
- Department of Cardiology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, China
| | - Caide Jin
- Department of Cardiology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, China
| | - Panke Chen
- Department of Cardiology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, China
| | - Shuai Ma
- Department of Cardiology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, China
| | - Bei Shi
- Department of Cardiology, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, China.
| |
Collapse
|
2
|
Wang H, Wang Q, Hu J, Zhang R, Gao T, Rong S, Dong H. Global research trends in in-stent neoatherosclerosis: A CiteSpace-based visual analysis. Front Cardiovasc Med 2022; 9:1025858. [PMID: 36426225 PMCID: PMC9679497 DOI: 10.3389/fcvm.2022.1025858] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Accepted: 10/25/2022] [Indexed: 08/27/2023] Open
Abstract
BACKGROUND Recent studies have shown that in-stent neoatherosclerosis (ISNA/NA) is an important cause of late stent failure. A comprehensive understanding of the current state of research in this field will facilitate the analysis of its development trends and hot frontiers. However, no bibliometric correlation has been reported yet. Here, we analyze the relevant literature since the emergence of the concept and provide valuable insights. METHODS Publications were collected from the Web of Science Core Collection (WoSCC) and PubMed. Microsoft Excel, SPSS and CiteSpace were used to analyze and present the data. RESULTS A total of 498 articles were collected, with Japan and Cardiovasc Res Fdn being the main publishing forces in all country/region and institutions. J AM COLL CARDIOL is the journal with the most published and co-cited articles. According to co-citation analysis, optical coherence tomography, thrombosis, implantation, restenosis, drug-eluting stent, and bare metal stent have become more and more popular recently. CONCLUSION ISNA is a niche and emerging field. How to reduce the incidence of ISNA and improve the late patency rate of coronary stents may remain a hot spot for future research. The pathogenesis of ISNA also needs to be explored in more depth.
Collapse
Affiliation(s)
- Heng Wang
- Department of Vascular Surgery, The Second Hospital of Shanxi Medical University, Taiyuan, China
| | - Qian Wang
- Department of Cardiology, The Second Hospital of Shanxi Medical University, Taiyuan, China
| | - Jie Hu
- Department of Vascular Surgery, The Second Hospital of Shanxi Medical University, Taiyuan, China
| | - Ruijing Zhang
- Department of Nephrology, The Second Hospital of Shanxi Medical University, Taiyuan, China
| | - Tingting Gao
- Department of Vascular Surgery, The Second Hospital of Shanxi Medical University, Taiyuan, China
| | - Shuling Rong
- Department of Cardiology, The Second Hospital of Shanxi Medical University, Taiyuan, China
| | - Honglin Dong
- Department of Vascular Surgery, The Second Hospital of Shanxi Medical University, Taiyuan, China
| |
Collapse
|
3
|
Wang J, Yuan S, Qi J, Zhang Q, Ji Z. Advantages and prospects of optical coherence tomography in interventional therapy of coronary heart disease (Review). Exp Ther Med 2022; 23:255. [PMID: 35261627 PMCID: PMC8855506 DOI: 10.3892/etm.2022.11180] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 01/13/2022] [Indexed: 11/06/2022] Open
Affiliation(s)
- Jie Wang
- Department of Cardiology, Tangshan Gongren Hospital Affiliated of North China University of Science and Technology, Tangshan, Hebei 063000, P.R. China
| | - Shuo Yuan
- Key Laboratory of Natural Medicines of the Changbai Mountain, Ministry of Education, College of Pharmacy, Yanbian University, Yanji, Jilin 133002, P.R. China
| | - Jingjing Qi
- Department of Cardiology, Tangshan Gongren Hospital Affiliated of North China University of Science and Technology, Tangshan, Hebei 063000, P.R. China
| | - Qinggao Zhang
- Chronic Diseases Research Center, Medical College, Dalian University, Dalian, Liaoning 116622, P.R. China
| | - Zheng Ji
- Department of Cardiology, Tangshan Gongren Hospital Affiliated of North China University of Science and Technology, Tangshan, Hebei 063000, P.R. China
| |
Collapse
|
4
|
Ellert J, Antonsen L, Jensen LO. Early restenose in a polymer-free Biolimus A9-coated stent (BioFreedom): A case report based on optical coherence tomography. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2016; 18:207-211. [PMID: 27650886 DOI: 10.1016/j.carrev.2016.08.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2016] [Accepted: 08/31/2016] [Indexed: 10/21/2022]
Abstract
An 81-year-old male patient with a severe de novo coronary artery stenosis in the proximal left anterior descending artery was treated with a BioFreedom stent (3.5×11mm), three months later, the patient was re-admitted with chest pain and slightly increased troponin. The angiogram showed a significant in-stent restenosis in the recently treated lesion. Optical coherence tomography revealed a fully expanded stent without areas of incomplete stent apposition. Severe immature neointimal hyperplasia without formation of thrombosis was visualized, causing a severe in-stent restenosis. An underlying plaque rupture within the mid-proximal part of the in-stent restenosis was evident.
Collapse
Affiliation(s)
- Julia Ellert
- Department of Cardiology, Odense University Hospital, Odense, Denmark.
| | - Lisbeth Antonsen
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | | |
Collapse
|
5
|
Zhang BC, Karanasos A, Regar E. OCT demonstrating neoatherosclerosis as part of the continuous process of coronary artery disease. Herz 2015; 40:845-54. [PMID: 26259732 PMCID: PMC4569676 DOI: 10.1007/s00059-015-4343-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Although the advent of drug-eluting stents has reduced the rates of target vessel revascularization, there are observations of ongoing stent failure occurring very late after stent implantation and presenting as very late restenosis or as very late stent thrombosis. The de novo development of atherosclerosis within the neointimal region, called neoatherosclerosis, has been identified as one of the pathomechanisms of these observed late stent failures. The mechanisms of neoatherosclerosis development and its association with stent failure are currently the subject of intensive research. Optical coherence tomography (OCT) is an invasive imaging modality that allows us to visualize the micromorphology of coronary arteries with near-histological resolution, thus providing detailed assessment of the morphological characteristics of the neointima after stent implantation, including neoatherosclerosis. Several OCT studies have tried to provide in vivo insights in the mechanisms of neoatherosclerosis development and its association with late stent failure. This review summarizes the current insights into neoatherosclerosis obtained with OCT and discusses the association of neoatherosclerosis with late stent failure.
Collapse
Affiliation(s)
- B-C Zhang
- Department of Cardiology, Thorax Center, Erasmus Medical Center, Room Ba-585, 's-Gravendijkwal 230, 3015, Rotterdam, The Netherlands
- Department of Cardiology, The Affiliated Hospital of Xuzhou Medical College, 221002, Jiangsu, China
| | - A Karanasos
- Department of Cardiology, Thorax Center, Erasmus Medical Center, Room Ba-585, 's-Gravendijkwal 230, 3015, Rotterdam, The Netherlands
| | - E Regar
- Department of Cardiology, Thorax Center, Erasmus Medical Center, Room Ba-585, 's-Gravendijkwal 230, 3015, Rotterdam, The Netherlands.
| |
Collapse
|
6
|
Bowen PK, Guillory RJ, Shearier ER, Seitz JM, Drelich J, Bocks M, Zhao F, Goldman J. Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 56:467-72. [PMID: 26249616 DOI: 10.1016/j.msec.2015.07.022] [Citation(s) in RCA: 108] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2015] [Revised: 07/07/2015] [Accepted: 07/10/2015] [Indexed: 11/27/2022]
Abstract
Although corrosion resistant bare metal stents are considered generally effective, their permanent presence in a diseased artery is an increasingly recognized limitation due to the potential for long-term complications. We previously reported that metallic zinc exhibited an ideal biocorrosion rate within murine aortas, thus raising the possibility of zinc as a candidate base material for endovascular stenting applications. This study was undertaken to further assess the arterial biocompatibility of metallic zinc. Metallic zinc wires were punctured and advanced into the rat abdominal aorta lumen for up to 6.5months. This study demonstrated that metallic zinc did not provoke responses that often contribute to restenosis. Low cell densities and neointimal tissue thickness, along with tissue regeneration within the corroding implant, point to optimal biocompatibility of corroding zinc. Furthermore, the lack of progression in neointimal tissue thickness over 6.5months or the presence of smooth muscle cells near the zinc implant suggest that the products of zinc corrosion may suppress the activities of inflammatory and smooth muscle cells.
Collapse
Affiliation(s)
- Patrick K Bowen
- Department of Materials Science and Engineering, Michigan Technological University, Houghton, MI 49931, USA.
| | - Roger J Guillory
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931, USA
| | - Emily R Shearier
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931, USA
| | - Jan-Marten Seitz
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931, USA; Department of Materials Science and Engineering, Michigan Technological University, Houghton, MI 49931, USA
| | - Jaroslaw Drelich
- Department of Materials Science and Engineering, Michigan Technological University, Houghton, MI 49931, USA
| | - Martin Bocks
- University of Michigan Congenital Heart Center, Division of Pediatric Cardiology, Ann Arbor, MI 48109, USA
| | - Feng Zhao
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931, USA
| | - Jeremy Goldman
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931, USA.
| |
Collapse
|
7
|
The basics of intravascular optical coherence tomography. ADVANCES IN INTERVENTIONAL CARDIOLOGY 2015; 11:74-83. [PMID: 26161097 PMCID: PMC4495121 DOI: 10.5114/pwki.2015.52278] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2014] [Revised: 01/12/2015] [Accepted: 05/09/2015] [Indexed: 12/23/2022] Open
Abstract
Optical coherence tomography (OCT) has opened new horizons for intravascular coronary imaging. It utilizes near-infrared light to provide a microscopic insight into the pathology of coronary arteries in vivo. Optical coherence tomography is also capable of identifying the chemical composition of atherosclerotic plaques and detecting traits of their vulnerability. At present it is the only tool to measure the thickness of the fibrous cap covering the lipid core of the atheroma, and thus it is an exceptional modality to detect plaques that are prone to rupture (thin fibrous cap atheromas). Moreover, it facilitates distinguishing between plaque rupture and plaque erosion as a cause of acute intracoronary thrombosis. Optical coherence tomography is applied to guide angioplasties of coronary lesions and to assess outcomes of percutaneous coronary interventions broadly. It identifies stent malapposition, dissections, and thrombosis with unprecedented precision. Furthermore, OCT helps to monitor vessel healing after stenting. It evaluates the coverage of stent struts by the neointima and detects in-stent neoatherosclerosis. With so much potential, new studies are warranted to determine OCT's clinical impact. The following review presents the technical background, basics of OCT image interpretation, and practical tips for adequate OCT imaging, and outlines its established and potential clinical application.
Collapse
|
8
|
Al Mamary A, Dariol G, Napodano M. Neo-atherosclerosis in very late stent thrombosis of drug eluting stent. J Saudi Heart Assoc 2014; 26:226-30. [DOI: 10.1016/j.jsha.2014.01.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2013] [Revised: 01/14/2014] [Accepted: 01/16/2014] [Indexed: 10/25/2022] Open
|
9
|
Intra-stent tissue evaluation within bare metal and drug-eluting stents > 3 years since implantation in patients with mild to moderate neointimal proliferation using optical coherence tomography and virtual histology intravascular ultrasound. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2014; 15:149-55. [PMID: 24767313 DOI: 10.1016/j.carrev.2014.01.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2014] [Accepted: 01/14/2014] [Indexed: 10/25/2022]
Abstract
OBJECTIVE We aimed to compare neointimal tissue characteristics between bare-metal stents (BMS) and drug-eluting stents (DES) at long-term follow-up using optical coherence tomography (OCT) and virtual histology intravascular ultrasound (VH-IVUS). BACKGROUND Neoatherosclerosis in neointima has been reported in BMS and in DES. METHODS Thirty patients with 36 stented lesions [BMS (n=17) or DES (n=19)] >3years after implantation were prospectively enrolled. OCT and VH-IVUS were performed and analyzed independently. Stents with ≥70% diameter stenosis were excluded. RESULTS The median duration from implantation was 126.0months in the BMS group and 60.0months in the DES group (p <0.001). Lipid-laden intima (58.8% vs. 42.1%, p=0.317), thrombus (17.6% vs. 5.3%, p=0.326), and calcification (35.3% vs. 26.3%, p=0.559) did not show significant differences between BMS and DES. When divided into 3 time periods, the cumulative incidence of lipid-laden neointima from >3years to <9years was similar between BMS and DES (42.9% vs. 42.1%, p=1.000). Furthermore, it continued to gradually increase over time in both groups. OCT-derived thin-cap fibroatheroma (TCFA) was observed in 17.6% of BMS- and 5.3% of DES-treated lesions (p=0.326). No stents had evidence of intimal disruption. The percentage volume of necrotic core (16.1% [9.7, 20.3] vs. 9.7% [7.0, 16.5], p=0.062) and dense calcium (9.5% [3.8, 13.6] vs. 2.7% [0.4, 4.9], p=0.080) in neointima tended to be greater in BMS-treated lesions. Intra-stent VH-TCFA (BMS vs. DES 45.5% vs. 18.2%, p=0.361) did not differ significantly. CONCLUSION At long-term follow-up beyond 3 years after implantation, the intra-stent neointimal tissue characteristics appeared similar for both BMS and DES.
Collapse
|