1
|
Zaed I, Schiavon G, Milani D, Cardia A. Letter to Editor Regarding: "Perception of Robotics and Navigation by Spine Fellows and Early Attendings: The Impact of These Technologies on Their Training and Practice". World Neurosurg 2024; 190:525. [PMID: 39425274 DOI: 10.1016/j.wneu.2024.07.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Accepted: 07/02/2024] [Indexed: 10/21/2024]
Affiliation(s)
- Ismail Zaed
- Department of Neurosurgery, Neurocenter of the Southern Switzerland, Regional Hospital of Lugano, Lugano, Switzerland.
| | - Guglielmo Schiavon
- Department of Neurosurgery, Neurocenter of the Southern Switzerland, Regional Hospital of Lugano, Lugano, Switzerland
| | - Davide Milani
- Department of Neurosurgery, Neurocenter of the Southern Switzerland, Regional Hospital of Lugano, Lugano, Switzerland
| | - Andrea Cardia
- Department of Neurosurgery, Neurocenter of the Southern Switzerland, Regional Hospital of Lugano, Lugano, Switzerland
| |
Collapse
|
2
|
Haida DM, Mohr P, Won SY, Möhlig T, Holl M, Enk T, Hanschen M, Huber-Wagner S. Hybrid-3D robotic suite in spine and trauma surgery - experiences in 210 patients. J Orthop Surg Res 2024; 19:565. [PMID: 39272126 PMCID: PMC11401291 DOI: 10.1186/s13018-024-05044-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2024] [Accepted: 08/31/2024] [Indexed: 09/15/2024] Open
Abstract
BACKGROUND In modern Hybrid ORs, the synergies of navigation and robotics are assumed to contribute to the optimisation of the treatment in trauma, orthopaedic and spine surgery. Despite promising evidence in the area of navigation and robotics, previous publications have not definitively proven the potential benefits. Therefore, the aim of this retrospective study was to evaluate the potential benefit and clinical outcome of patients treated in a fully equipped 3D-Navigation Hybrid OR. METHODS Prospective data was collected (March 2022- March 2024) after implementation of a fully equipped 3D-Navigation Hybrid OR ("Robotic Suite") in the authors level 1 trauma centre. The OR includes a navigation unit, a cone beam CT (CBCT), a robotic arm and mixed reality glasses. Surgeries with different indications of the spine, the pelvis (pelvic ring and acetabulum) and the extremities were performed. Spinal and non-spinal screws were inserted. The collected data was analysed retrospectively. Pedicle screw accuracy was graded according to the Gertzbein and Robbins (GR) classification. RESULTS A total of n = 210 patients (118 m:92f) were treated in our 3D-Navigation Hybrid OR, with 1171 screws inserted. Among these patients, 23 patients (11.0%) arrived at the hospital via the trauma room with an average Injury Severity Score (ISS) of 25.7. There were 1035 (88.4%) spinal screws inserted at an accuracy rate of 98.7% (CI95%: 98.1-99.4%; 911 GR-A & 111 GR-B screws). The number of non-spinal screws were 136 (11.6%) with an accuracy rate of 99.3% (CI95%: 97.8-100.0%; 135 correctly placed screws). This resulted in an overall accuracy rate of 98.8% (CI95%: 98.2-99.4%). The robotic arm was used in 152 cases (72.4%), minimally invasive surgery (MIS) was performed in 139 cases (66.2%) and wound infection occurred in 4 cases (1,9%). Overall, no revisions were needed. CONCLUSION By extending the scope of application, this study showed that interventions in a fully equipped 3D-Navigation Hybrid OR can be successfully performed not only on the spine, but also on the pelvis and extremities. In trauma, orthopaedics and spinal surgery, navigation and robotics can be used to perform operations with a high degree of precision, increased safety, reduced radiation exposure for the OR-team and a very low complication rate.
Collapse
Affiliation(s)
- Dominik M Haida
- Department of Trauma Surgery, Technical University of Munich, Klinikum rechts der Isar, Ismaninger Straße 22, 81675, Munich, Germany
- Department of Trauma Surgery, Diakonie-Klinikum Schwäbisch Hall, Diakoniestraße 10, 74523, Schwäbisch Hall, Germany
| | - Peter Mohr
- Radiation Protection, Diakonie-Klinikum Schwäbisch Hall, Diakoniestraße 10, 74523, Schwäbisch Hall, Germany
| | - Sae-Yeon Won
- Department of Neurosurgery, Rostock University Medical Center, Schillingallee 35, 18057, Rostock, Germany
| | - Thorsten Möhlig
- Department of Trauma Surgery, Diakonie-Klinikum Schwäbisch Hall, Diakoniestraße 10, 74523, Schwäbisch Hall, Germany
| | - Mike Holl
- Department of Trauma Surgery, Diakonie-Klinikum Schwäbisch Hall, Diakoniestraße 10, 74523, Schwäbisch Hall, Germany
| | - Thorsten Enk
- Department of Neurosurgery, Diakonie-Klinikum Schwäbisch Hall, Diakoniestraße 10, 74523, Schwäbisch Hall, Germany
| | - Marc Hanschen
- Department of Trauma Surgery, Technical University of Munich, Klinikum rechts der Isar, Ismaninger Straße 22, 81675, Munich, Germany
| | - Stefan Huber-Wagner
- Department of Trauma Surgery, Technical University of Munich, Klinikum rechts der Isar, Ismaninger Straße 22, 81675, Munich, Germany.
- Department of Trauma Surgery, Diakonie-Klinikum Schwäbisch Hall, Diakoniestraße 10, 74523, Schwäbisch Hall, Germany.
| |
Collapse
|
3
|
Suarez-Ahedo C, Lopez-Reyes A, Martinez-Armenta C, Martinez-Gomez LE, Martinez-Nava GA, Pineda C, Vanegas-Contla DR, Domb B. Revolutionizing orthopedics: a comprehensive review of robot-assisted surgery, clinical outcomes, and the future of patient care. J Robot Surg 2023; 17:2575-2581. [PMID: 37639163 DOI: 10.1007/s11701-023-01697-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 08/14/2023] [Indexed: 08/29/2023]
Abstract
Robotic-assisted orthopedic surgery (RAOS) is revolutionizing the field, offering the potential for increased accuracy and precision and improved patient outcomes. This comprehensive review explores the historical perspective, current robotic systems, advantages and limitations, clinical outcomes, patient satisfaction, future developments, and innovation in RAOS. Based on systematic reviews, meta-analyses, and recent studies, this article highlights the most significant findings and compares RAOS to conventional techniques. As robotic-assisted surgery continues to evolve, clinicians and researchers must stay informed and adapt their practices to provide optimal patient care. Evidence from published studies corroborates these claims, highlighting superior component positioning, decreased incidence of complications, and heightened patient satisfaction. However, challenges such as costs, learning curves, and technical issues must be resolved to fully capitalize on these advantages.
Collapse
Affiliation(s)
- Carlos Suarez-Ahedo
- Instituto Nacional de Rehabilitación, Mexico City, Mexico.
- American Hip Institute, Des Plaines, IL, USA.
| | | | | | | | | | - Carlos Pineda
- Instituto Nacional de Rehabilitación, Mexico City, Mexico
| | | | | |
Collapse
|
4
|
Altameem A, Shaheer Akhtar M, Altameem T, Fouad H, Anil S, Kim YS, Youssef AE. Responsive Policy Decisions for Improving the Accuracy of Medical Data Analysis in Healthcare-Based Human–Machine Interaction Systems. INT J HUM ROBOT 2023; 20. [DOI: 10.1142/s0219843622400072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2024]
Abstract
Human–computer interaction (HCI) is deployed in various real-time applications, including healthcare, for automated patient response. In such applications, robot-assisted interactive scenarios are modeled to handle patient queries and provide precise information. Timely query sensing and accurate data analysis are required to achieve accurate patient responses. In this study, responsive policy decision (RPD) using manifold mediator learning (MML) is introduced to improve data detection accuracy and accuracy in robot-assisted HCI applications. The initial decision-making process in data analytics is based on interaction stages and medical data detection. After identifying the most appropriate policy, respondents are provided with time-based responses based on the patient’s queries. When it comes to improving the accuracy of data analysis decisions, machine learning uses policies based on interaction stages and previous state efficiency of HCI responses. The experimental analysis proves the reliability of the proposed method by improving the accuracy of data analysis and reducing its complexity and response time for the varying queries and time intervals.
Collapse
Affiliation(s)
- Ahmed Altameem
- Computer Science, CC, King Saud University Riyadh, Saudi Arabia
| | - M. Shaheer Akhtar
- New & Renewable Energy Material Development Center (New REC), Jeonbuk National University, Jeonju, Republic of Korea
| | - Torki Altameem
- Computer Science, CC, King Saud University Riyadh, Saudi Arabia
| | - H. Fouad
- Biomedical Engineering Department, Faculty of Engineering, Helwan University, Cairo, Egypt
| | - Sukumaran Anil
- Department of Dentistry-Oral Health Institute, Hamad Medical Corporation, Doha, Qatar
- College of Dental Medicine, Qatar University, Doha, Qatar
| | - Young Soon Kim
- Institute of Carbon Technology, Jeonju University, Jeonju, Republic of Korea
| | - Ahmed E. Youssef
- Department of Computers & Systems Engineering, Faculty of Engineering at Helwan, Helwan University, Cairo, Egypt
| |
Collapse
|
5
|
Pan A, Ding H, Hai Y, Liu Y, Hai JJ, Yin P, Han B. The Value of Three-Dimensional Printing Spine Model in Severe Spine Deformity Correction Surgery. Global Spine J 2023; 13:787-795. [PMID: 33973487 DOI: 10.1177/21925682211008830] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
STUDY DESIGN Retrospective case-control study. OBJECTIVE We aimed to evaluate the value of 3-dimensional printing (3DP) spine model in the surgical treatment of severe spinal deformity since the prosperous development of 3DP technology. METHODS Severe scoliosis or hyper-kyphosis patients underwent posterior fixation and fusion surgery using the 3DP spine models were reviewed (3DP group). Spinal deformity surgeries operated by free-hand screw implantation during the same period were selected as the control group after propensity score matching (PSM). The correction rate, pedicle screw accuracy, and complications were analyzed. Class A and B screws were defined as accurate according to Gertzbein and Robbins criteria. RESULTS 35 patients were enrolled in the 3DP group and 35 matched cases were included in the control group. The perioperative baseline data and deformity correction rate were similar between both groups (P > .05). However, the operation time and blood loss were significantly less in the 3DP group (296.14 ± 66.18 min vs. 329.43 ± 67.16 min, 711.43 ± 552.28 mL vs. 1322.29 ± 828.23 mL, P < .05). More three-column osteotomies (Grade 3-6) were performed in the 3DP group (30/35, 85.7% vs. 21/35, 60.0%. P = .016). The screw placement accuracy was significantly higher in the 3DP group (422/582, 72.51% vs. 397/575, 69.04%. P = .024). The screw misplacement related complication rate was significantly higher in the free-hand group (6/35 vs. 1/35, P = .046). CONCLUSIONS The study provided solid evidence that 3DP spine models can enhance surgeons' confidence in performing higher grade osteotomies and improve the safety and efficiency in severe spine deformity correction surgery. 3D printing technology has a good prospect in spinal deformity surgery.
Collapse
Affiliation(s)
- Aixing Pan
- Department of Orthopedic Surgery, 74639Beijing Chao-Yang Hospital, Capital Medical University, Chaoyang District, Beijing, China
| | - Hongtao Ding
- Department of Orthopedic Surgery, 74639Beijing Chao-Yang Hospital, Capital Medical University, Chaoyang District, Beijing, China
| | - Yong Hai
- Department of Orthopedic Surgery, 74639Beijing Chao-Yang Hospital, Capital Medical University, Chaoyang District, Beijing, China
| | - Yuzeng Liu
- Department of Orthopedic Surgery, 74639Beijing Chao-Yang Hospital, Capital Medical University, Chaoyang District, Beijing, China
| | - Junrui Jonathan Hai
- 261768The High School Affiliated to Renmin University of China, Haidian District, Beijing, China
| | - Peng Yin
- Department of Orthopedic Surgery, 74639Beijing Chao-Yang Hospital, Capital Medical University, Chaoyang District, Beijing, China
| | - Bo Han
- Department of Orthopedic Surgery, 74639Beijing Chao-Yang Hospital, Capital Medical University, Chaoyang District, Beijing, China
| |
Collapse
|
6
|
Robot-assisted percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a retrospective matched-cohort study. INTERNATIONAL ORTHOPAEDICS 2023; 47:595-604. [PMID: 36520167 DOI: 10.1007/s00264-022-05654-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 12/03/2022] [Indexed: 12/23/2022]
Abstract
PURPOSE This study aims to introduce the principle, clinical efficacy, and learning curve of robot-assisted percutaneous vertebroplasty (PVP). METHODS Forty-two patients who underwent robot-assisted single-level PVP were analyzed retrospectively and 42 age-matched patients using freehand technique were selected as the control group. The visual analog scale, operation time, radiation exposure, accuracy, and learning curve were analyzed. RESULTS The puncture time and total operation time were significantly shorter, and the puncture and total fluoroscopy number were fewer in the robot group. The deviation between pre-operative planned and actual puncture trajectory well met clinical requirement. The puncture time, total operation time, and puncture fluoroscopy number were significantly more in early cases than in later cases in the robot group. CONCLUSION The robot-assisted pedicle puncture technique shortens the operation time and reduces radiation exposure, and the accuracy meets the clinical requirement in PVP. The learning curve is short and not steep.
Collapse
|
7
|
Li Q, Gu G, Wang L, Song R, Qi L. Using EMG signals to assess proximity of instruments to nerve roots during robot-assisted spinal surgery. Int J Med Robot 2022; 18:e2408. [PMID: 35472826 DOI: 10.1002/rcs.2408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 04/13/2022] [Accepted: 04/17/2022] [Indexed: 11/06/2022]
Abstract
BACKGROUND Detecting neural threats using electromyography (EMG) has gained recognition in the field of spinal surgery. To provide an efficient approach to detect neural threats during the operation of the spinal surgery robot, an automated method based the internal connection between EMG signal and neural proximity (NP) was explored by experiments. METHODS A NP classifier was designed to distinguish the pattern of the threats. Then, it was evaluated in rabbit models in vivo. The experiments were conducted using 20 rabbits. In each rabbit, two puncture paths were created using a surgical robot. For each path, EMG signals were recorded at series of path-points with different neural proximities, and were constructed as datasets after data cleaning and processing. The proposed NP classifier was trained and tested on the datasets. RESULTS Classification accuracy of Path 1 and Path 2 were 99.1% and 94.0%, respectively. CONCLUSION This feasibility study proved that EMG can be used to detect the proximity of surgical instruments to nerve roots during robot-assisted spinal surgery. As the methods of detecting neural threats for surgical robots are still scarce, we believe this work will improve the clinical performance of spinal surgery robots and help the doctors to perform surgery safely.
Collapse
Affiliation(s)
- Qianqian Li
- School and Hospital of Stomatology, Shandong University, Jinan, China
| | - Guanghui Gu
- Orthopedics Department, Qilu Hospital, Shandong University, Jinan, China
| | - Liang Wang
- Orthopedics Department, Qilu Hospital, Shandong University, Jinan, China
| | - Rui Song
- School of Control Science and Engineering, Shandong University, Jinan, China
| | - Lei Qi
- Orthopedics Department, Qilu Hospital, Shandong University, Jinan, China
| |
Collapse
|
8
|
Garg B, Mehta N. Great Expectations with Augmented Reality in Spine Surgery: Hope or Hype?A commentary on the article 'Operator independent reliability of direct augmented reality navigated pedicle screw placement and rod bending' by Farshad et al. NORTH AMERICAN SPINE SOCIETY JOURNAL 2022; 10:100117. [PMID: 35540023 PMCID: PMC9079716 DOI: 10.1016/j.xnsj.2022.100117] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 04/05/2022] [Accepted: 04/08/2022] [Indexed: 11/19/2022]
Affiliation(s)
- Bhavuk Garg
- Department of Orthopaedics, All India Institute of Medical Sciences, New Delhi, India
| | - Nishank Mehta
- Department of Orthopaedics, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|
9
|
Cunningham BW, Brooks DM. Comparative Analysis of Optoelectronic Accuracy in the Laboratory Setting Versus Clinical Operative Environment: A Systematic Review. Global Spine J 2022; 12:59S-74S. [PMID: 35393881 PMCID: PMC8998481 DOI: 10.1177/21925682211035083] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
STUDY DESIGN Systematic review. OBJECTIVES The optoelectronic camera source and data interpolation process serve as the foundation for navigational integrity in robotic-assisted surgical platforms. The current systematic review serves to provide a basis for the numerical disparity observed when comparing the intrinsic accuracy of optoelectronic cameras versus accuracy in the laboratory setting and clinical operative environments. METHODS Review of the PubMed and Cochrane Library research databases was performed. The exhaustive literature compilation obtained was then vetted to reduce redundancies and categorized into topics of intrinsic accuracy, registration accuracy, musculoskeletal kinematic platforms, and clinical operative platforms. RESULTS A total of 465 references were vetted and 137 comprise the basis for the current analysis. Regardless of application, the common denominators affecting overall optoelectronic accuracy are intrinsic accuracy, registration accuracy, and application accuracy. Intrinsic accuracy equaled or was less than 0.1 mm translation and 0.1 degrees rotation per fiducial. Controlled laboratory platforms reported 0.1 to 0.5 mm translation and 0.1 to 1.0 degrees rotation per array. Accuracy in robotic-assisted spinal surgery reported 1.5 to 6.0 mm translation and 1.5 to 5.0 degrees rotation when comparing planned to final implant position. CONCLUSIONS Navigational integrity and maintenance of fidelity of optoelectronic data is the cornerstone of robotic-assisted spinal surgery. Transitioning from controlled laboratory to clinical operative environments requires an increased number of steps in the optoelectronic kinematic chain and error potential. Diligence in planning, fiducial positioning, system registration and intra-operative workflow have the potential to improve accuracy and decrease disparity between planned and final implant position.
Collapse
Affiliation(s)
- Bryan W. Cunningham
- Department of Orthopaedic Surgery, Musculoskeletal Research and Innovation Institute, MedStar Union Memorial Hospital, Baltimore, MD, USA
- Department of Orthopaedic Surgery, Georgetown University School of Medicine, Washington, DC, USA
| | - Daina M. Brooks
- Department of Orthopaedic Surgery, Musculoskeletal Research and Innovation Institute, MedStar Union Memorial Hospital, Baltimore, MD, USA
| |
Collapse
|
10
|
Karasin B, Rizzo G, Hardinge T, Grzelak M, Eskuchen L, Watkinson J. Robotic-Assisted Lumbar Fusion: An Effective Technique for Pedicle Screw Placement. AORN J 2022; 115:251-260. [PMID: 35213051 DOI: 10.1002/aorn.13612] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 06/08/2021] [Accepted: 07/10/2021] [Indexed: 12/19/2022]
Abstract
Degenerative lumbar disease is a common condition in which progressive deterioration of the structures in the spine causes severely incapacitating pain and disability. Conservative management, including passive or active physical therapy, activity modification, and medications (eg, anti-inflammatory medications, oral and injectable steroids, opioids), may provide relief. However, when conservative management is unsuccessful or patients experience symptoms for an extended period of time, they may require spine surgery. Surgeons use a variety of techniques to perform lumbar fusion procedures with instrumentation, including open, percutaneous, minimally invasive, and robotic-assisted with navigation. The accuracy of pedicle-screw placement varies according to the technique used, and accuracy rates are high after robotic-assisted with navigation procedures. In addition, robotic-assisted spine procedures result in fewer infections than non-robotic-assisted spine procedures (P = .04). Perioperative nurses should understand basic lumbar spine anatomy, steps completed during robotic-assisted lumbar spine surgery, and the nursing considerations for patients undergoing this type of procedure.
Collapse
|
11
|
Judy BF, Pennington Z, Botros D, Tsehay Y, Kopparapu S, Liu A, Theodore N, Zakaria HM. Spine Image Guidance and Robotics: Exposure, Education, Training, and the Learning Curve. Int J Spine Surg 2021; 15:S28-S37. [PMID: 34675029 DOI: 10.14444/8138] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Abstract
The use of intraoperative robotics and imaging for spine surgery has been shown to be safe, efficacious, and beneficial to patients, offering accurate placement of instrumentation, decreased operative time and blood loss, and improved postoperative outcomes. Despite these proven benefits, it has yet to be uniformly adopted. One of the major barriers for universal adoption of intraoperative robotics is the learning curve for this complex technology, in conjunction with a lack of formalized training. These same obstacles for universal adoption were faced in the introduction of surgical technology in other disciplines, and the use of this technology has become the standard of care in some of those specialties. Part of the success and widespread implementation of prior novel technology was the introduction of formalized training systems, which are currently lacking in advanced spine surgical technology. Therefore, the future success of intraoperative robotics and imaging for spine surgery depends on the creation of a formalized training system. We detail the best techniques for surgical pedagogy, as well as propose a comprehensive curriculum.
Collapse
Affiliation(s)
- Brendan F Judy
- Department of Neurosurgery, Johns Hopkins Hospital, Baltimore, Maryland
| | | | - David Botros
- Department of Neurosurgery, Johns Hopkins Hospital, Baltimore, Maryland
| | - Yohannes Tsehay
- Department of Neurosurgery, Johns Hopkins Hospital, Baltimore, Maryland
| | - Srujan Kopparapu
- Department of Neurosurgery, Johns Hopkins Hospital, Baltimore, Maryland
| | - Ann Liu
- Department of Neurosurgery, Johns Hopkins Hospital, Baltimore, Maryland
| | - Nicholas Theodore
- Department of Neurosurgery, Johns Hopkins Hospital, Baltimore, Maryland
| | - Hesham M Zakaria
- Department of Neurosurgery, Johns Hopkins Hospital, Baltimore, Maryland
| |
Collapse
|
12
|
Cunningham BW, Brooks DM, McAfee PC. Accuracy of Robotic-Assisted Spinal Surgery-Comparison to TJR Robotics, da Vinci Robotics, and Optoelectronic Laboratory Robotics. Int J Spine Surg 2021; 15:S38-S55. [PMID: 34607917 PMCID: PMC8532535 DOI: 10.14444/8139] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
BACKGROUND The optoelectronic camera source and data interpolation serve as the foundation for navigational integrity in the robotic-assisted surgical platform. The objective of the current systematic review serves to provide a basis for the numerical disparity that exists when comparing the intrinsic accuracy of optoelectronic cameras: accuracy observed in the laboratory setting versus accuracy in the clinical operative environment. It is postulated that there exists a greater number of connections in the optoelectronic kinematic chain when analyzing the clinical operative environment to the laboratory setting. This increase in data interpolation, coupled with intraoperative workflow challenges, reduces the degree of accuracy based on surgical application and to that observed in controlled musculoskeletal kinematic laboratory investigations. METHODS Review of the PubMed and Cochrane Library research databases was performed. The exhaustive literature compilation obtained was then vetted to reduce redundancies and categorized into topics of intrinsic optoelectronic accuracy, registration accuracy, musculoskeletal kinematic platforms, and clinical operative platforms. RESULTS A total of 147 references make up the basis for the current analysis. Regardless of application, the common denominators affecting overall optoelectronic accuracy are intrinsic accuracy, registration accuracy, and application accuracy. Intrinsic accuracy of optoelectronic tracking equaled or was less than 0.1 mm of translation and 0.1° of rotation per fiducial. Controlled laboratory platforms reported 0.1 to 0.5 mm of translation and 0.1°-1.0° of rotation per array. There is a huge falloff in clinical applications: accuracy in robotic-assisted spinal surgery reported 1.5 to 6.0 mm of translation and 1.5° to 5.0° of rotation when comparing planned to final implant position. Total Joint Robotics and da Vinci urologic robotics computed accuracy, as predicted, lies between these two extremes-1.02 mm for da Vinci and 2 mm for MAKO. CONCLUSIONS Navigational integrity and maintenance of fidelity of optoelectronic data is the cornerstone of robotic-assisted spinal surgery. Transitioning from controlled laboratory to clinical operative environments requires an increased number of steps in the optoelectronic kinematic chain and error potential. Diligence in planning, fiducial positioning, system registration, and intraoperative workflow have the potential to improve accuracy and decrease disparity between planned and final implant position. The key determining factors limiting navigation resolution accuracy are highlighted by this Cochrane research analysis.
Collapse
Affiliation(s)
- Bryan W. Cunningham
- Musculoskeletal Education Center, Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, Baltimore, Maryland
- Department of Orthopaedic Surgery, Georgetown University School of Medicine, Washington, D.C
| | - Daina M. Brooks
- Musculoskeletal Education Center, Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, Baltimore, Maryland
| | - Paul C. McAfee
- Musculoskeletal Education Center, Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, Baltimore, Maryland
- Department of Orthopaedic Surgery, Georgetown University School of Medicine, Washington, D.C
| |
Collapse
|
13
|
Garg B. What is new in spine surgery? J Clin Orthop Trauma 2020; 11:729. [PMID: 32879560 PMCID: PMC7452188 DOI: 10.1016/j.jcot.2020.07.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
Affiliation(s)
- Bhavuk Garg
- Department of Orthopedics, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|