1
|
Netteland DF, Aarhus M, Sandset EC, Padayachy L, Helseth E, Brekken R. In Reply: Noninvasive Assessment of Intracranial Pressure: Deformability Index as an Adjunct to Optic Nerve Sheath Diameter to Increase Diagnostic Ability. Neurocrit Care 2024; 41:307-309. [PMID: 38951443 DOI: 10.1007/s12028-024-02027-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Accepted: 05/23/2024] [Indexed: 07/03/2024]
Affiliation(s)
- Dag Ferner Netteland
- Department of Neurosurgery, Oslo University Hospital, Oslo, Norway.
- Faculty of Medicine, University of Oslo, Oslo, Norway.
| | - Mads Aarhus
- Department of Neurosurgery, Oslo University Hospital, Oslo, Norway
| | - Else Charlotte Sandset
- Department of Neurology, Oslo University Hospital, Oslo, Norway
- The Norwegian Air Ambulance Foundation, Oslo, Norway
| | - Llewellyn Padayachy
- Department of Neurosurgery, School of Medicine, Faculty of Health Sciences, University of Pretoria, Steve Biko Academic Hospital, Pretoria, South Africa
| | - Eirik Helseth
- Department of Neurosurgery, Oslo University Hospital, Oslo, Norway
- Faculty of Medicine, University of Oslo, Oslo, Norway
| | - Reidar Brekken
- Department of Health Research, Medical Technology, SINTEF, Trondheim, Norway
| |
Collapse
|
2
|
Suresh V, Magoon R. Comment on "Noninvasive Assessment of Intracranial Pressure: Deformability Index as an Adjunct to Optic Nerve Sheath Diameter to Increase Diagnostic Ability". Neurocrit Care 2024; 41:303-304. [PMID: 38951445 DOI: 10.1007/s12028-024-02025-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Accepted: 05/23/2024] [Indexed: 07/03/2024]
Affiliation(s)
- Varun Suresh
- Department of Anesthesia and Intensive Care, Jaber Al Ahmad Al Sabah Hospital, Kuwait-Arabian Gulf, Kuwait.
| | - Rohan Magoon
- Department of Anesthesia, Atal Bihari Vajpayee Institute of Medical Sciences (ABVIMS) and Dr. Ram Manohar Lohia Hospital, Baba Kharak Singh Marg, New Delhi, 110001, India
| |
Collapse
|
3
|
Pansell J, Bottai M, Bell M, Rudberg PC, Friman O, Cooray C. Which compartments of the optic nerve and its sheath are associated with intracranial pressure? An exploratory study. J Neuroimaging 2024. [PMID: 39034603 DOI: 10.1111/jon.13224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Revised: 07/08/2024] [Accepted: 07/10/2024] [Indexed: 07/23/2024] Open
Abstract
BACKGROUND AND PURPOSE The optic nerve sheath diameter (ONSD) is a commonly used estimate of intracranial pressure (ICP). The rationale behind this is that pressure changes in the cerebrospinal fluid affect the optic nerve subarachnoid space (ONSAS) thickness. Still, possible effects on other compartments of the optic nerve sheath (ONS) have not been studied. This is the first study ever to analyze all measurable compartments of the ONS for associations with elevated ICP. METHODS We measured changes in ICP and changes in ONS compartments in 75 patients treated with invasive ICP monitoring at the Karolinska University Hospital. Associations between changes in ICP and changes in ONS compartments were estimated with generalized estimating equations. The potential to identify elevated ICP was assessed with the area under the receiver operating characteristic curve (AUROC) for ONS compartments associated with ICP changes. RESULTS Both ONSAS and perioptic dura mater thickness were significantly associated with changes in ICP in multivariable modeling. ONSAS was the only compartment that independently predicted changes in ICP, with an AUROC of 0.69 for predicting ICP increase. Still, both the perioptic dura mater thickness and the optic nerve diameter added value in predicting ICP changes in multivariable modeling. CONCLUSIONS The results from this study challenge the current understanding of the mechanism behind the association between ICP and ONSD. Contrary to the common opinion that ONSAS is the only affected compartment, this study shows a more complex picture. It suggests that all ONS compartments may add value in predicting changes in ICP.
Collapse
Affiliation(s)
- Jakob Pansell
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
- Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Stockholm, Sweden
| | - Matteo Bottai
- Division of Biostatistics, Institute of Environmental Medicine, Karolinska Institutet, Stockholm, Sweden
| | - Max Bell
- Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Stockholm, Sweden
- Department of Physiology & Pharmacology, Karolinska Institutet, Stockholm, Sweden
| | - Peter C Rudberg
- Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Stockholm, Sweden
- Department of Physiology & Pharmacology, Karolinska Institutet, Stockholm, Sweden
| | - Ola Friman
- Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Stockholm, Sweden
| | - Charith Cooray
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
- Department of Clinical Neurophysiology, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
4
|
Xu X, Lu Y, Liu J, Xu R, Zhao K, Tao A. Diagnostic Value of the Combination of Ultrasonographic Optic Nerve Sheath Diameter and Width of Crural Cistern with Respect to the Intracranial Pressure in Patients Treated with Decompressive Craniotomy. Neurocrit Care 2023; 39:436-444. [PMID: 37037992 DOI: 10.1007/s12028-023-01711-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 02/28/2023] [Indexed: 04/12/2023]
Abstract
BACKGROUND The monitoring of intracranial pressure (ICP) and detection of increased ICP are crucial because such increases may cause secondary brain injury and a poor prognosis. Although numerous ultrasound parameters, including optic nerve sheath diameter (ONSD), width of the crural cistern (WCC), and the flow velocities of the central retinal artery and middle cerebral artery, can be measured in patients after hemicraniectomy, researchers have yet to determine which of these is better for evaluating ICP. This study aimed to analyze the correlation between ICP and ultrasound parameters and investigate the best noninvasive estimator of ICP. METHODS This observational study enrolled 50 patients with brain injury after hemicraniectomy from January 2021 to December 2021. All patients underwent invasive ICP monitoring with microsensor, transcranial, and ocular ultrasound postoperatively. We measured the ONSD including the dura mater (ONSDI), the ONSD excluding the dura mater, the optic nerve diameter (OND), the eyeball transverse diameter (ETD), the WCC, and the flow velocities in the central retinal artery and middle cerebral artery. Then, we calculated the ONSDI-OND (the difference between ONSDI and OND) and ONSDI/ETD (the ratio of ONSDI to ETD). Patients were divided into a normal ICP group (n = 35) and an increased ICP group (≥ 20 mm Hg, n = 15) according to the ICP measurements. Correlations were then assessed between the values of the ultrasound parameters and ICP. RESULTS The ONSDI, ONSDI-OND, and ONSDI/ETD were positively associated with ICP (r = 0.455, 0.482, 0.423 and p = 0.001, < 0.001, 0.002, respectively), whereas the WCC was negatively associated with ICP (r = - 0.586, p < 0.001). The WCC showed the highest predictive power for increased ICP (area under the receiver operating characteristic curve [AUC] = 0.904), whereas the ONSDI-OND and ONSDI also presented with acceptable predictive power among the ONSD-related parameters (AUC = 0.831, 0.803, respectively). The cutoff values for increased ICP prediction for ONSDI, ONSDI-OND, and WCC were 6.29, 3.03, and 3.68 mm, respectively. The AUC of the combination of ONSDI-OND and WCC was 0.952 (95% confidence interval 0.896-1.0, p < 0.001). CONCLUSIONS The ONSDI, ONSDI-OND, and WCC were correlated with ICP and had acceptable accuracy levels in estimating ICP in patients after hemicraniectomy. Furthermore, WCC showed a higher diagnostic value than ONSD-related parameters, and the combination of ONSDI-OND and WCC was a satisfactory predictor of increased ICP.
Collapse
Affiliation(s)
- Xiaolan Xu
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Yajing Lu
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Jiqiao Liu
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Renfan Xu
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Kai Zhao
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Anyu Tao
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China.
| |
Collapse
|
5
|
Heinz ER, Keneally R, d'Empaire PP, Vincent A. Current status of point of care ultrasonography for the perioperative care of trauma patients. Curr Opin Anaesthesiol 2023; 36:168-175. [PMID: 36550092 DOI: 10.1097/aco.0000000000001229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
PURPOSE OF REVIEW The incorporation of point of care ultrasound into the field of anesthesiology and perioperative medicine is growing at rapid pace. The benefits of this modality align with the acuity of patient care and decision-making in anesthetic care of a trauma patient. RECENT FINDINGS Cardiac ultrasound can be used to diagnose cardiac tamponade or investigate the inferior vena cava to assess volume status in patients who may suffer from hemorrhagic shock. Thoracic ultrasound may be used to rapidly identify pneumothorax or hemothorax in a patient suffering chest wall trauma. In addition, investigators are exploring the utility of ultrasonography in traumatic airway management and elevated intracranial pressure. In addition, the utility of gastric ultrasound on trauma patients is briefly discussed. SUMMARY Incorporation of point of care ultrasound techniques into the practice of trauma anesthesiology is important for noninvasive, mobile and expeditious assessment of trauma patients. In addition, further large-scale studies are needed to investigate how point of care ultrasound impacts outcomes in trauma patients.
Collapse
Affiliation(s)
- Eric R Heinz
- Department of Anesthesiology and Critical Care Medicine. George Washington University, Washington, District of Columbia, USA
| | - Ryan Keneally
- Department of Anesthesiology and Critical Care Medicine. George Washington University, Washington, District of Columbia, USA
| | - Pablo Perez d'Empaire
- Department of Anesthesiology and Pain Medicine, Department of Anesthesia, Sunnybrook Health Sciences Centre University of Toronto, Toronto, Canada
| | - Anita Vincent
- Department of Anesthesiology and Critical Care Medicine. George Washington University, Washington, District of Columbia, USA
| |
Collapse
|
6
|
Pansell J, Bell M, Rudberg P, Friman O, Cooray C. Optic nerve sheath diameter in intracranial hypertension: Measurement external or internal of the dura mater? J Neuroimaging 2023; 33:58-66. [PMID: 36197323 PMCID: PMC10092179 DOI: 10.1111/jon.13062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 09/05/2022] [Accepted: 09/23/2022] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND AND PURPOSE Optic nerve sheath diameter (ONSD) is a promising metric to estimate intracranial pressure (ICP). There is no consensus whether ONSD should be measured external (ONSDext) or internal (ONSDint) of the dura mater. Expert opinion favors ONSDint, though without clear evidence to support this. Adjustments of ONSD for eye diameter (ED) and optic nerve diameter (OND) have been suggested to improve precision. We examined the diagnostic accuracy of ONSDext and ONSDint for estimating ICP, unadjusted as well as adjusted for ED and OND. METHODS We performed an observational cohort study, measuring ONSDext and ONSDint in patients with invasive ICP monitoring at Karolinska University Hospital in Stockholm, Sweden. We used ONSDext and ONSDint unadjusted as well as adjusted for ED and for OND. We compared the area under the receiver operator characteristics curve (AUROC) for these methods. Thresholds for elevated ICP were set at ≥20 and ≥22 mmHg, respectively. RESULTS We included 220 measurements from 100 patients. Median ONSDext and ONSDint were significantly different at 6.7 and 5.2 mm (p = .00). There was no significant difference in AUROC for predicting elevated ICP between ONSDext and ONSDint (.67 vs. .64, p = .31). Adjustment for ED yielded better diagnostic accuracy (AUROC, cutoff, sensitivity, specificity) for ONSDext/ED (.76, .29, .81, .62) and ONSDint/ED (.71, .24, .5, .89). CONCLUSIONS ONSDext and ONSDint differ significantly and are not interchangeable. However, there were no significant differences in diagnostic accuracy between ONSDext and ONSDint. Adjustment for ED may improve diagnostic accuracy of ONSD.
Collapse
Affiliation(s)
- Jakob Pansell
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Stockholm, Sweden
| | - Max Bell
- Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Stockholm, Sweden.,Department of Physiology & Pharmacology, Karolinska Institutet, Stockholm, Sweden
| | - Peter Rudberg
- Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Stockholm, Sweden.,Department of Physiology & Pharmacology, Karolinska Institutet, Stockholm, Sweden
| | - Ola Friman
- Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Stockholm, Sweden
| | - Charith Cooray
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Clinical Neurophysiology, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
7
|
Pansell J, Bell M, Rudberg P, Friman O, Cooray C. Optic nerve sheath diameter measurement by ultrasound: Evaluation of a standardized protocol. J Neuroimaging 2021; 32:104-110. [PMID: 34555223 DOI: 10.1111/jon.12936] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 09/08/2021] [Accepted: 09/10/2021] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND AND PURPOSE Treatment of elevated intracranial pressure (ICP) is central to neurocritical care, but not all patients are eligible for invasive ICP-monitoring. A promising noninvasive option is ultrasound measurement of the optic nerve sheath diameter (ONSD). However, meta-analyses of ONSD for elevated ICP show wide confidence intervals. This might be due to baseline variations, inter-rater variability, and varying measurement methods. No standardized protocol has been validated. Corrections for eyeball diameter (ED) and optic nerve diameter (OND) may compensate for baseline variations. We evaluated a protocol and compared two different measurement methods for ONSD ultrasound. METHODS Two operators, blinded to each other's measurements, measured ONSD, ED, and OND twice in 20 patients. ONSD was measured with two different methods in use: internal (ONSDint) or external (ONSDext) of the dura mater. Intra-class correlation (ICC) was calculated for inter-rater and intra-rater reliability. RESULTS ICCs for inter-rater reliability of ONSDext and ONSDint (95% confidence interval) were 0.96 (0.93, 0.98) and 0.88 (0.79, 0.94), respectively. ICCs for intra-rater reliability of ONSDext and ONSDint were 0.97 (0.94, 0.99) and 0.93 (0.87, 0.96), respectively. There was no significant bias or difference in intra-rater reliability between operators. CONCLUSIONS ONSD can be measured with an excellent inter- and intra-rater reliability and low risk of inter-rater bias, when using this protocol. ONSDext yields a higher inter- and intra-rater reliability than ONSDint. Corrections for ED and OND can be performed reliably.
Collapse
Affiliation(s)
- Jakob Pansell
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Stockholm, Sweden
| | - Max Bell
- Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Stockholm, Sweden.,Department of Physiology & Pharmacology, Karolinska Institutet, Stockholm, Sweden
| | - Peter Rudberg
- Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Stockholm, Sweden.,Department of Physiology & Pharmacology, Karolinska Institutet, Stockholm, Sweden
| | - Ola Friman
- Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Stockholm, Sweden
| | - Charith Cooray
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Clinical Neurophysiology, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
8
|
Letter to the editor: Dynamic optic nerve sheath diameter changes upon moderate hyperventilation in patients with traumatic brain injury. J Crit Care 2020; 63:275-276. [PMID: 32814646 DOI: 10.1016/j.jcrc.2020.07.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Accepted: 07/31/2020] [Indexed: 11/22/2022]
|