1
|
Buckhurst PJ, Wolffsohn JS, Davies LN, Naroo SA. Surgical correction of astigmatism during cataract surgery. Clin Exp Optom 2021; 93:409-18. [PMID: 20735787 DOI: 10.1111/j.1444-0938.2010.00515.x] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Affiliation(s)
- Phillip J Buckhurst
- Aston University, Life and Health Sciences, Ophthalmic Research Group, Birmingham, United Kingdom
E‐mail:
| | - James S Wolffsohn
- Aston University, Life and Health Sciences, Ophthalmic Research Group, Birmingham, United Kingdom
E‐mail:
| | - Leon N Davies
- Aston University, Life and Health Sciences, Ophthalmic Research Group, Birmingham, United Kingdom
E‐mail:
| | - Shehzad A Naroo
- Aston University, Life and Health Sciences, Ophthalmic Research Group, Birmingham, United Kingdom
E‐mail:
| |
Collapse
|
2
|
Ghoreishi M, Kashfi A, Peyman M, Mohammadinia M. Comparison of Toric Implantable Collamer Lens and Toric Artiflex Phakic IOLs in Terms of Visual Outcome: a Paired Contralateral Eye Study. Am J Ophthalmol 2020; 219:186-194. [PMID: 32621900 DOI: 10.1016/j.ajo.2020.06.021] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Revised: 06/14/2020] [Accepted: 06/15/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE This study sought to compare the postoperative visual outcomes of toric implantable collamer lens (T-ICL) with toric Artiflex (T-Artiflex) lenses. DESIGN Alternating treatment, contralateral eye matched clinical study. METHODS This study compared 82 eyes of 41 patients with T-ICL lenses in one eye and toric Artiflex implantation in the contralateral eye to correct myopic astigmatism. Safety, efficacy, predictability, astigmatic vector changes, contrast sensitivity, endothelial cell count, and possible adverse events were assessed at least 12 months postoperatively. RESULTS After a mean follow-up of 12 months, the safety index was mean 1.40 ± 0.70 in the T-ICL group and 1.20 ± 0.21 in the T-Artiflex group. Furthermore, their mean efficacy indexes were 1.24 ± 0.42 and 1.08 ± 0.23, respectively (P = .029). A total of 39 eyes (95%) in the T-ICL group and 41 eyes (100%) in the T-Artiflex group were within ±1.00 diopter (D) of emmetropia and 33 eyes (80%) and 34 eyes (83%) were within ±0.5 D of emmetropia, respectively. Vector analysis revealed mean index of success as large as 0.25 ± 0.22 in the T-ICL group and 0.24 ± 0.15 in the T-Artiflex group. Postoperative contrast sensitivities were equal in both groups under mesopic conditions for any given spatial frequency. There was an endothelial loss of 2.18% and 1.95% in the T-ICL and T-Artiflex groups, respectively. There were no significant complications in any of the groups. CONCLUSIONS Both lenses showed promising results in terms of safety, efficacy, and predictability for correction of myopic astigmatism. As shown in this paired-eye study, most outcomes were almost identical, and neither of these lenses were clinically superior to the other.
Collapse
|
3
|
Eichenbaum DA, Buznego C, Weng CY, Dhoot DS, Wykoff CC, Sheth VS. When and How to Incorporate Steroids for Persistent Diabetic Macular Edema: A Discussion of Real-World Treatment Optimization Strategies. Ophthalmic Surg Lasers Imaging Retina 2019; 49:S5-S15. [PMID: 30021031 DOI: 10.3928/23258160-20180621-01] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
In the United States, diabetic macular edema (DME) is the leading cause of vision loss among people with diabetic retinopathy. Despite the availability of different therapies for DME, up to half of patients with DME show some persistent edema after anti-vascular endothelial growth factor (VEGF) treatment alone, leaving these patients at high risk for vision loss. However, dosing in a similar fashion to that of pivotal anti-VEGF trials is difficult because of real-life challenges faced in clinical practice. This is particularly true for DME, in that the frequency and burden of anti-VEGF injections are a major challenge to patient care. Research evaluating anti-VEGF therapies has shaped the treatment paradigms for patients with DME, and similar benefits have also been noted in clinical trials evaluating the use of intravitreal steroids. Treatment with a long-term intravitreal corticosteroid, which requires fewer injections than treatment with most short-acting therapies, has been found to reduce inflammation and improve vision in a percentage of patients. This roundtable discussion, which took place during the 2018 annual meeting of the Vit-Buckle Society, reviews the current treatment paradigms for DME and evaluates how to customize and optimize treatment strategies geared toward individualized patient care. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:S5-S15.].
Collapse
|
4
|
Lee J, Lee H, Kang DSY, Choi JY, Kim EK, Kim TI. Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High Myopic Astigmatism. Yonsei Med J 2016; 57:1475-81. [PMID: 27593877 PMCID: PMC5011281 DOI: 10.3349/ymj.2016.57.6.1475] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Revised: 04/15/2016] [Accepted: 04/26/2016] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To compare the effectiveness of toric foldable iris-fixated phakic intraocular lens (pIOL) implantation and non-toric foldable iris-fixated pIOL implantation with limbal relaxing incisions (LRIs) for correcting moderate-to-high astigmatism in myopic eyes. MATERIALS AND METHODS The medical records of 146 patients (195 eyes) with myopic astigmatism who underwent toric foldable iris-fixated pIOL implantation (toric group; 94 eyes) or non-toric foldable iris-fixated pIOL implantation with concurrent LRIs (LRI group; 101 eyes) were retrospectively reviewed. For subgroup analysis, the two groups were subdivided according to preoperative astigmatic severity [moderate, 2.00 to <3.00 diopters (D); high, 3.00-4.00 D]. Visual and astigmatic outcomes were compared 6 months postoperatively. RESULTS The uncorrected distance visual acuity was at least 20/25 in 100% and 98% of the toric and LRI group eyes, respectively. The toric group had lower mean residual cylindrical error (-0.67±0.39 D vs. -1.14±0.56 D; p<0.001) and greater mean cylindrical error change (2.17±0.56 D vs. 1.63±0.72 D; p<0.001) than the LRI group, regardless of the preoperative astigmatic severity. The mean correction index (1.10±0.16 vs. 0.72±0.24; p<0.001) and success index (0.24±0.14 vs. 0.42±0.21; p<0.001) also differed significantly between the groups. CONCLUSION Both surgical techniques considerably reduced astigmatism and had comparable visual outcomes. However, toric foldable iris-fixated pIOL implantation was more reliable for correcting moderate-to-high astigmatism in myopic eyes.
Collapse
Affiliation(s)
- Jeihoon Lee
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
| | - Hun Lee
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
- Department of Ophthalmology, International St. Mary's Hospital, Catholic Kwandong University College of Medicine, Incheon, Korea
| | | | - Jin Young Choi
- The Institute of Vision Research, Eyereum Eye Clinic, Seoul, Korea
| | - Eung Kweon Kim
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
- Corneal Dystrophy Research Institute, Severance Biomedical Science Institute, and Brain Korea 21 Plus Project for Medical Science, Yonsei University College of Medicine, Seoul, Korea
| | - Tae Im Kim
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.
| |
Collapse
|
5
|
Awadein A, Habib AE. ICL versus Veriflex phakic IOL for treatment of moderately high myopia: randomized paired-eye comparison. J Refract Surg 2013; 29:445-52. [PMID: 23820226 DOI: 10.3928/1081597x-20130617-02] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2012] [Accepted: 03/20/2013] [Indexed: 11/20/2022]
Abstract
PURPOSE To compare the objective and subjective outcome of implantable collamer lenses (ICLs; Staar Surgical, Monrovia, CA) versus Veriflex lenses (AMO, Santa Ana, CA) for the correction of moderately high myopia. METHODS A prospective randomized comparative eye study was performed on 24 patients with bilateral myopia that ranged from -6 to -14.5 diopters (D). One eye was implanted with an ICL and the other eye was implanted with a Veriflex phakic intraocular lens (PIOL). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), higher-order aberrations (HOAs), contrast sensitivity, patient satisfaction, central endothelial cell count, and PIOL centration were determined 6 months after surgery RESULTS The logMAR UDVA and CDVA improved significantly in both groups (P < .001). There was no statistically significant difference in postoperative logMAR UDVA (P = .41) or logMAR CDVA (P = .36) between the two groups. Postoperative deviation from target refraction was -0.06 ± 0.41 D in the ICL group and -0.07 ± 0.49 D in the Veriflex group (P = .15). The difference in both induced and absolute postoperative HOAs between groups was not statistically significant. The area under the log contrast sensitivity function increased significantly in both groups postoperatively. The difference in patient satisfaction between both PIOLs was not statistically significant. A higher but statistically insignificant central endothelial cell count loss occurred in the Veriflex group (P = .11). CONCLUSION Both ICL and Veriflex PIOLs have equally satisfactory objective and subjective visual outcomes after surgery.
Collapse
|
6
|
Pérez-Cambrodí RJ, Piñero DP, Blanes-Mompó FJ, Ferrer-Blasco T, Cerviño A. Preliminary in vivo positional analysis of a posterior chamber phakic intraocular lens by optical coherence tomography and its correlation with clinical outcomes. JOURNAL OF OPTOMETRY 2012; 5:121-130. [PMCID: PMC3860978 DOI: 10.1016/j.optom.2012.04.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2012] [Accepted: 03/20/2012] [Indexed: 06/10/2023]
Abstract
Purpose To analyze by spectral-domain optical coherence tomography the anatomical relationship of a specific type of posterior chamber phakic intraocular lens (pIOL) implanted in cases of high to moderate myopia with the adjacent intraocular structures and to correlate it with clinical outcomes. Methods Prospective observational case series including 18 eyes with high to moderate myopia (spherical equivalent between −5.88 and −15.75 D) of 9 patients (age range, 29–49 years) undergoing bilateral Phakic Refractive Lens (PRL, Zeiss) implantation. Postoperative visual acuity, refraction, contrast sensitivity (CS), and ocular higher order aberrations (HOA) were evaluated. Furthermore, the in vivo position of the PRL was analyzed by means of spectral domain optical coherence tomography (3D OCT-1000, Topcon). Central (CENV), temporal (TEMV) and nasal vault (NASV) were measured. Correlation of these anatomical parameters with clinical data was also investigated. Mean follow-up was 47 ± 25 months. Results A statistically significant visual and refractive improvement (p < 0.01) was found postoperatively. Mean postoperative CENV, NASV, and TEMV were 157.88 ± 69.93 μm, 168.29 ± 65.02 μm, and 188.59 ± 55.99 μm, respectively. Significant difference was found between NASV and TEMV (p = 0.01). No significant correlations were found between ocular aberrometric and anatomical parameters (p ≥ 0.12). CENV, NASV and TEMV correlated significantly with 6-cycles per degree (cpd) photopic CS as well as with 18-cpd low mesopic CS (r ≥ 0.57, p ≤ 0.04). Furthermore, NASV also correlated significantly with preoperative anterior chamber depth (r = −0.65, p = 0.01). Conclusions This posterior chamber pIOL shows a trend to nasal position, with potential impact on refractive and visual outcomes, particularly in eyes with deep anterior chambers.
Collapse
Affiliation(s)
- Rafael J. Pérez-Cambrodí
- Optometry Research Group, Department of Optics, University of Valencia, Spain
- Alicante Oftalmológica, Oftalmar, Hospital Internacional Medimar, Alicante, Spain
| | - David P. Piñero
- Foundation for the Visual Quality (FUNCAVIS, Fundación para la Calidad Visual), Alicante, Spain
- Departamento de Óptica, Farmacología y Anatomía, Universidad de Alicante, Spain
| | | | | | - Alejandro Cerviño
- Optometry Research Group, Department of Optics, University of Valencia, Spain
| |
Collapse
|
7
|
Hayashi K, Kondo H, Yoshida M, Manabe SI, Hirata A. Higher-order aberrations and visual function in pseudophakic eyes with a toric intraocular lens. J Cataract Refract Surg 2012; 38:1156-65. [PMID: 22608030 DOI: 10.1016/j.jcrs.2012.02.032] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2011] [Revised: 02/08/2012] [Accepted: 02/10/2012] [Indexed: 11/15/2022]
Abstract
PURPOSE To compare higher-order aberrations (HOAs) and visual function in eyes with a toric intraocular lens (IOL) and eyes with a nontoric IOL. SETTING Hayashi Eye Hospital, Fukuoka, Japan. DESIGN Case-control study. METHODS Eyes that had phacoemulsification were enrolled in 1 of the following 3 groups: (1) preoperative corneal astigmatism of 1.00 diopter (D) with a toric IOL (toric group), (2) astigmatism of 1.00 D or more with a nontoric IOL (high-astigmatism group), and (3) astigmatism less than 1.00 D with a nontoric IOL (low-astigmatism group). Ocular and corneal HOAs were measured using a wavefront analyzer. Photopic and mesopic visual acuities at high- to low-contrast visual targets were measured using a contrast sensitivity tester. RESULTS The mean ocular and corneal total HOAs and 3rd-order aberrations in the toric and high-astigmatism groups tended to be greater than in the low-astigmatism group; HOAs and 3rd-order aberrations at 3 months and HOAs at 6 months were significantly different (P ≤.0403). The mean corrected visual acuity did not differ significantly between groups. However, photopic low-contrast visual acuity (LCVA) and mesopic high- to low-contrast visual acuity was significantly worse in the toric and high-astigmatism groups than in the low-astigmatism group (P ≤.0210). CONCLUSION Postoperatively, ocular and corneal HOAs were greater in eyes with a toric IOL and in eyes with high preexisting corneal astigmatism than in eyes with low preexisting astigmatism, which impaired photopic LCVA and mesopic visual acuity. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.
Collapse
|
8
|
Five-year follow-up after anterior iris-fixated intraocular lens implantation in phakic eyes to correct high myopia. Eye (Lond) 2011; 26:321-6. [PMID: 22134588 DOI: 10.1038/eye.2011.292] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To evaluate the 5-year follow-up of safety, efficacy, predictability, stability, and complications of anterior iris-fixated phakic intraocular lens (pIOL) implantation to correct high myopia, and patients' satisfaction after implantation. DESIGN Prospective, nonrandomized, and comparative (self-controlled) trial. METHODS A prospective clinical trial of 84 eyes of 43 patients with high myopia was conducted. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), refraction, endothelial cell count, intraocular pressure (IOP), anterior chamber depth, slit lamp biomicroscopy, and indirect ophthalmoscope were measured preoperatively and postoperatively. RESULTS At the 5-year follow-up, UCVA was significantly improved, with 85.7% of eyes reaching 20/25 or better. No eyes experienced a loss in BSCVA, and 71.4% gained one or more lines of their preoperative BSCVA. There was a significant reduction in spherical errors in all patients after operation. Loss of endothelial cells was observed 3 years after operation and no more loss was observed 4 years after operation in statistical analysis. No increase in IOP was observed 5 years after operation in statistical analysis. No intraoperative complications were observed in this study. However, pigment precipitates of varying intensities on the lens optic were noted in all patients 1 day after operation, and only five eyes were observed to have the pigment residual five years after operation. CONCLUSION At the 5-year follow-up, the implantation of the anterior iris-fixated pIOL was proved to be effective, predictable and capable of reversibility to correct high myopia in phakic eyes. It was a safety addition to the laser refractive surgery. However, longer follow-up with larger numbers of patients is still necessary to evaluate long-term complications.
Collapse
|
9
|
Felipe A, Artigas JM, Díez-Ajenjo A, García-Domene C, Alcocer P. Residual astigmatism produced by toric intraocular lens rotation. J Cataract Refract Surg 2011; 37:1895-901. [PMID: 21865007 DOI: 10.1016/j.jcrs.2011.04.036] [Citation(s) in RCA: 84] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2010] [Revised: 03/30/2011] [Accepted: 04/07/2011] [Indexed: 11/29/2022]
Abstract
PURPOSE To analyze changes in the eye's refractive properties when a toric intraocular lens (IOL) rotates. SETTING Fundación Oftalmológica del Mediterráneo, Valencia, Spain. DESIGN Experimental study. METHODS The matrix definition of astigmatism was used in this theoretical study and compared with another vector representation. Two methods were compared: (1) The cylinder, C, resulting from the addition of 2 cylinders C(1) and C(2) whose axes form an angle a, is obtained by the addition of 2 vectors of values C(1) and C(2) forming an angle 2a; (2) the power matrix, F, of a thin astigmatic dioptric system that decomposes naturally into 3 orthogonal components: the purely spherical part F(nes,) the ortho-astigmatism F(or), and oblique astigmatism F(ob). RESULTS The residual cylinder was one third of the corneal astigmatism when a toric IOL rotated ±10 degrees when the cylinder values for the cornea (C(1)) and IOL (C(2)) were equal. Nevertheless, in most cases C(1) is greater than C(2); therefore, the residual astigmatism did not change noticeably with small rotations. The angle of rotation, b, which annuls the astigmatism correction, could be obtained from the following: cos(π + 2b) = -r/2, with r being the ratio between the IOL and cornea cylinders. CONCLUSIONS The 2 methods gave equivalent results. When the IOL cylinder had a value different from that of the corneal astigmatism, a better choice would be a lower, rather than higher, cylinder value to reduce residual astigmatism. In general, toric IOL rotations less than 10 degrees changed the eye's refraction less than 0.50 diopter. Thus, small axis rotations are not an obstacle for satisfactory astigmatism correction with toric IOLs. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.
Collapse
Affiliation(s)
- Adelina Felipe
- Fundación Oftalmológica del Mediterráneo, Facultad de Física, Universidad de Valencia, Burjassot (Valencia), Spain.
| | | | | | | | | |
Collapse
|
10
|
Park DH, Lane SS. Phakic Myopic Intraocular Lenses. Cornea 2011. [DOI: 10.1016/b978-0-323-06387-6.00178-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
11
|
van Philips LA. High and Low Contrast Visual Acuity After Artiflex Phakic Intraocular Lens Implantation for the Correction of Myopia. J Refract Surg 2010; 26:423-9. [DOI: 10.3928/1081597x-20090710-05] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2008] [Accepted: 06/11/2009] [Indexed: 11/20/2022]
|
12
|
Elies D, Alonso T, Puig J, Gris O, Güell JL, Coret A. Visian Toric Implantable Collamer Lens for Correction of Compound Myopic Astigmatism. J Refract Surg 2010; 26:251-8. [DOI: 10.3928/1081597x-20100218-02] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2008] [Accepted: 03/31/2009] [Indexed: 11/20/2022]
|
13
|
Seo JH, Kim MK, Wee WR, Lee JH. Effects of white-to-white diameter and anterior chamber depth on implantable collamer lens vault and visual outcome. J Refract Surg 2009; 25:730-8. [PMID: 19714798 DOI: 10.3928/1081597x-20090707-08] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To investigate the effects of anterior chamber depth (ACD) and white-to-white (WTW) diameter on vault in eyes with implantable collamer lenses (ICL V4, STAAR Surgical AG) and to evaluate the effect of vault on visual outcomes and other biometric changes. METHODS Twenty-eight eyes of 16 patients who underwent ICL implantation were retrospectively reviewed. Patients were divided into two groups (A1, A2) according to preoperative ACD (> or = 3.3 mm and < 3.3 mm, respectively), two groups (B1, B2) based on WTW diameter (> or = 11.55 mm and < 11.55 mm, respectively), and two groups (C1, C2) according to the difference of ICL diameter and sulcus length (> or = 0.25 mm and < 0.25 mm, respectively). Vault, endothelial cell density, and visual performance were compared between each set of groups. Correlations of vault with WTW diameter, ACD, and diametric difference of the ICL from the sulcus were analyzed. RESULTS The high ACD and WTW groups showed significantly higher vaults (0.59 +/- 0.32 mm and 0.57 +/- 0.36 mm, respectively) than the low ACD and WTW groups (0.26 +/- 0.17 mm and 0.25 +/- 0.14 mm, respectively; P = .01 and .01), whereas the differences of diameter between the sulcus and ICL were not related to significant vault differences. The WTW diameter wascorrelated more closely to the vault than the ACD or sulcus diameter (r = 0.70, P < .001), whereas the vault difference did not affect visual quality or endothelial cell density. CONCLUSIONS A high WTW diameter or ACD is likely to render a high vault, regardless of any difference in the ICL and sulcus diameters.
Collapse
Affiliation(s)
- Je Hyun Seo
- Department of Ophthalmology, Seoul National University Hospital, Korea
| | | | | | | |
Collapse
|
14
|
|
15
|
|
16
|
Five-Year Follow-up of 399 Phakic Artisan–Verisyse Implantation for Myopia, Hyperopia, and/or Astigmatism. Ophthalmology 2008; 115:1002-12. [PMID: 17980432 DOI: 10.1016/j.ophtha.2007.08.022] [Citation(s) in RCA: 104] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2006] [Revised: 08/06/2007] [Accepted: 08/10/2007] [Indexed: 11/21/2022] Open
|
17
|
Kohnen T, Cichocki M, Koss MJ. Position of rigid and foldable iris-fixated myopic phakic intraocular lenses evaluated by Scheimpflug photography. J Cataract Refract Surg 2008; 34:114-20. [PMID: 18165090 DOI: 10.1016/j.jcrs.2007.08.037] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2007] [Accepted: 08/10/2007] [Indexed: 11/28/2022]
Abstract
PURPOSE To evaluate the postoperative intraocular positional stability of 1 rigid poly(methyl methacrylate) (PMMA) phakic intraocular lens (pIOL) model and 2 foldable polysilicone-PMMA iris-fixated pIOL models. SETTING Department of Ophthalmology, Johann Wolfgang Goethe-University Frankfurt am Main, Germany. METHODS One of 3 iris-fixated pIOL models (Artisan, Artiflex I, and Artiflex II, Ophtec BV) was implanted in 45 eyes of 26 patients with myopia or myopic astigmatism. The central distance between the pIOL and corneal endothelium and between the pIOL and anterior surface of the crystalline lens was evaluated using Scheimpflug photography 6 and 12 months after surgery. RESULTS The mean preoperative spherical equivalent was -9.32 diopters +/- 1.78 (SD) (range -6.5 to -13.5 D). Each IOL model was implanted in 15 eyes. The median distance from the central corneal endothelium to the anterior surface of the pIOL at 6 months and 12 months was 2.65 mm and 2.64 mm, respectively, in the Artisan group, 2.47 mm and 2.50 mm, respectively, in the Artiflex I group, and 2.48 mm and 2.52 mm, respectively, in the Artiflex II group. The median distance between the posterior surface of the pIOL and the anterior surface of the crystalline lens at 6 months and 12 months was 0.40 mm and 0.48 mm, respectively, in the Artisan group, 0.53 mm and 0.55 mm, respectively, in the Artiflex I group, and 0.68 mm and 0.66 mm, respectively, in the Artiflex II group. At 12 months, the distance between the pIOL and crystalline lens was statistically significantly greater in the Artiflex II group than in the Artisan group (P<.01). CONCLUSION The intraocular position of rigid pIOLs and foldable silicone iris-supported pIOLs showed a difference between the 3 pIOL models in space to the crystalline lens and the corneal endothelium, which may affect long-term results in terms of IOL interaction with surrounding tissue.
Collapse
Affiliation(s)
- Thomas Kohnen
- Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany.
| | | | | |
Collapse
|
18
|
Yu A, Wang Q, Xue A, Zhu S, Wang S, Chen Y, Sun J. Comparison of Contrast Sensitivity after Angle-Supported, Iris-Fixated and Posterior Chamber Phakic Intraocular Lens Implantation for High Myopia. Ophthalmologica 2007; 222:53-7. [DOI: 10.1159/000109280] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
19
|
Abstract
After more than 3 years of follow-up, the satisfactory results achieved with the toric iris-fixated phakic intraocular lens (IOL) mean we can regard implantation of this lens as a procedure with the potential to provide safe, predictable, effective and stable correction of astigmatic errors, providing patients are carefully selected and receive adequate preparation for surgery. The iris-fixated toric phakic IOL (Verisyse, Advanced Medical Optics; Artisan, Ophtec) is a PMMA lens with a total diameter of 8.5 mm and an optic diameter of 5 mm. It has a spherical anterior and a toric posterior surface. Its refractive power ranges from -2 dpt to -21 dpt for myopia and from +2 dpt to +12.5 dpt for the correction of hyperopia. Cylindrical correction is available from 2 dpt to 7.5 dpt. The Visian toric implantable Collamer lens (Staar) differs in that it is foldable and can be inserted through a very small incision of about 2.8 mm. It is placed in front of the natural lens in the ciliary sulcus. The aim of implanting these phakic IOLs is to correct the entire refractive error, meaning both the spherical and the astigmatic error, in a single step. Different lens models are available, and the selection depends on the direction of the cylinder axis and the anatomical situation, among other things.
Collapse
|
20
|
Güell JL, Morral M, Gris O, Gaytan J, Sisquella M, Manero F. Evaluation of Verisyse and Artiflex phakic intraocular lenses during accommodation using Visante optical coherence tomography. J Cataract Refract Surg 2007; 33:1398-404. [PMID: 17662431 DOI: 10.1016/j.jcrs.2007.04.026] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2007] [Accepted: 04/25/2007] [Indexed: 10/23/2022]
Abstract
PURPOSE To perform a dynamic study of the relationship between Verisyse (AMO) and Artiflex (Ophtec B.V.) phakic intraocular lenses (pIOLs) and anterior chamber structures during accommodation using optical coherence tomography (OCT) (Visante, Carl Zeiss Meditec, Inc.) SETTING Institutional practice. METHODS Eleven myopic patients were randomly selected to have implantation of a Verisyse pIOL in 1 eye and an Artiflex pIOL in the other. Using a 2-dimensional image, dynamic measurements of the relationship between the anterior surface of the pIOL and the corneal endothelium, the posterior surface of the pIOL and the anterior surface of the crystalline lens, and the pupil diameter were performed using Visante OCT. Physiological accommodation was stimulated by adding lenses in 1.00 diopter (D) steps from +1.00 to -7.00 D. RESULTS Both groups had a significant decrease in pupil diameter (P<.0001, generalized linear model [GLM]) and in the distance between the anterior surface of the pIOL and the corneal endothelium (P<.0001, GLM) with accommodation. There were no statistically significant changes in the distance between the posterior surface of either pIOL and the anterior surface of the crystalline lens (P = .2845, GLM). There were no statistically significant differences between the 2 pIOLs in any measurement (P>.05, GLM). CONCLUSIONS The results fit with Helmholtz' theory of accommodation as forward movement of the diaphragm iris-crystalline lens was seen. There was a decrease in the distance between the pIOL and corneal endothelium and in the pupil diameter, whereas the distance between both pIOLs and the crystalline lens remained constant throughout the accommodation examination. This suggests that the risk for cataract from intermittent contact between the crystalline lens and IOL from accommodative effort is unlikely.
Collapse
|
21
|
Abstract
At a time when some of the limitations of photoablation have been defined, such as worry concerning secondary ectasia, a renewed interest in phakic implantation has arisen. This is driven by the goal of avoiding correcting high ametropia with LASIK and is based on the development of soft foldable biomaterials. When all phakic IOLs are in front of the natural lens, two varieties of lenses can be distinguished, depending on whether it is located in the anterior or posterior chamber. The various models available in 2006 and those under current evaluation are reviewed. We do not report details of clinical studies that vary in cohort size and follow-up. The advantages and limitations are discussed for each type of phakic IOL. Adequate although not exclusive indications are deduced. There is no phakic lens that has proved to be superior to the others in terms of safety. All have the ability to provide a visual benefit with a gain in best corrected visual acuity. The difference is based on anatomical effects, requiring long-term follow-up in the evaluation of angles, lens, iris, and endothelium.
Collapse
|
22
|
Abstract
PURPOSE OF REVIEW Laser in-situ keratomileusis has been tremendously successful in treating patients with mild and moderate ametropias. For patients with high degrees of refractive error, however, phakic intraocular lenses provide superior quality of vision without the risk of corneal ectasia. Early international results, as well as United States Food and Drug Administration clinical trials, have demonstrated the early safety and efficacy of phakic intraocular lenses. Nevertheless, long-term corneal endothelium cell density and crystalline lens clarity remain a concern. RECENT FINDINGS Several new studies demonstrate the superior visual outcomes of phakic intraocular lenses over laser in-situ keratomileusis in patients with moderate and high myopia, particularly in the areas of visual quality and contrast sensitivity. New anterior segment imaging and measurement technologies have provided valuable information about in-vivo structure and function, with and without phakic lens implants. More is being learned about long-term endothelial cell stability and cataract formation, particularly in relation to implant positioning. New applications of phakic intraocular lenses in presbyopia and in other conditions are being explored. SUMMARY Once plagued by complications and marginal outcomes, improved designs of phakic intraocular lenses are providing increasing safety and efficacy for the correction of severe ametropias. Long-term concerns with endothelial cell loss remain, but recent data suggest stabilization with time. Proper sizing and positioning are important and increasingly achievable with new imaging modalities. With continued research and experience, phakic intraocular lenses are becoming an invaluable addition to the mainstream refractive surgery armamentarium.
Collapse
|
23
|
Tehrani M, Dick HB. Short-term Follow-up after Implantation of a Foldable Iris-Fixated Intraocular Lens in Phakic Eyes. Ophthalmology 2005; 112:2189-95. [PMID: 16243399 DOI: 10.1016/j.ophtha.2005.06.036] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2005] [Accepted: 06/22/2005] [Indexed: 10/25/2022] Open
Abstract
OBJECTIVE To evaluate efficiency, predictability, stability, complications, and patient satisfaction after implantation of a foldable iris-fixated phakic intraocular lens (PIOL) for the correction of myopia. DESIGN Prospective, nonrandomized, comparative (self-controlled) trial. PARTICIPANTS Forty-one eyes of 22 myopic patients aged 18 to 56 years (mean, 36 years) with average sphere of -8.2+/-2.01 diopters (D; range, -12.25 to -3.75 D) and average preoperative cylinder of -0.90+/-0.62 D (range, -2.50 to 0.00 D) were enrolled in this prospective study. METHODS All eyes underwent implantation of a foldable iris-fixated PIOL with an optical zone of 6.0 mm. The follow-up was 6 months in all cases. Phakic intraocular lenses were available in powers ranging from -2.0 D to -12.0 D. MAIN OUTCOME MEASURES The main parameters assessed were best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity, refraction, endothelial cell count, intraocular pressure, slit-lamp biomicroscopy, and indirect ophthalmoscopy. RESULTS At 6 months' follow-up, no eyes experienced a loss in BSCVA and 78% gained 1 or more lines of their preoperative BSCVA. Uncorrected visual acuity was significantly improved, with 82% of eyes reaching 20/25 or better. There was a significant reduction in spherical errors in all patients after surgery. Ninety-one percent of eyes were within +/-0.50 D of target refraction. A slight loss of endothelial cells (2.3 %) was observed 6 months after surgery. There were no intraoperative complications. In the postoperative follow-up, however, pigment precipitates were noted in 5 eyes of 4 patients. CONCLUSIONS At short-term follow-up, the implantation of the foldable iris-fixated PIOL proved to be effective and predictable for the correction of myopia in phakic eyes. However, longer follow-up with larger numbers of patients is necessary to evaluate long-term complications.
Collapse
Affiliation(s)
- Mana Tehrani
- Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.
| | | |
Collapse
|