1
|
Levinger N, Erdinest N, London N, Levinger E, Goldfeather Ben Zaken S, Barequet D, Barequet I, Achiron A, Levinger S. Femtosecond LASER-Assisted Double Intraocular Lens Exchange in Nanophthalmic Eyes. Case Rep Ophthalmol 2024; 15:143-149. [PMID: 38348443 PMCID: PMC10861217 DOI: 10.1159/000536190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 01/01/2024] [Indexed: 02/15/2024] Open
Abstract
Introduction Though patients with nanophthalmos frequently endure decreased quality of vision with contact lenses or spectacles, refractive surgery is generally an inadequate alternative due to the associated high refractive error. A refractive lens exchange (RLE) is an alternative option but is technically challenging, requiring accuracy in biometry measurements and procedures. Case Presentation This case discusses a 27-year-old female with nanophthalmos (axial lengths 17.6 mm and 17.4 mm, right and left eyes, respectively) who underwent a femtosecond laser-assisted (FLA) RLE with simultaneous implantation of a monofocal and a Sulcoflex trifocal (Rayner, Britain) lens in each eye. Preoperative cycloplegic refraction was +11.50/-0.75 × 145 and +12.00/-1.00 × 35 in the RE and LE, respectively. Best-corrected visual acuity (BCVA) at distance and near in the RE and LE was 6/7.5 and J1, 6/8.5 and J2, respectively. Uncorrected visual acuity (UCVA) was >6/120 and >J14 for each eye. FLA RLE was performed in the RE, then in the LE 2 weeks later. In each eye, a monofocal (44.0 D, RE, and LE) and a Sulcoflex trifocal lens (both implants, Rayner, Britain) were implanted in one procedure. Distance and near UCVA measured 6 weeks post-op RE and 1-month post-op LE at 6/8.5 and J1 in the RE, 6/10 and J1 in the LE. The RE and LE refraction and BCVA were +0.50/-1.00 × 115, 6/7.5, and plano/-1.00 × 55, 6/8.5, respectively. The post-op outcomes were uneventful. Conclusion A single procedure concurrently implanting a monofocal and Sulcoflex trifocal intraocular lens in nanophthalmic eyes resulted in an excellent UCVA. This procedure can be considered esthetic and reconstructive as it significantly improves patient appearance and function.
Collapse
Affiliation(s)
- Nadav Levinger
- Enaim Medical Center Jerusalem and Tel Aviv, Tel Aviv, Israel
- Hadassah Medical Center, Jerusalem, Israel
| | - Nir Erdinest
- Enaim Medical Center Jerusalem and Tel Aviv, Tel Aviv, Israel
| | | | - Eliya Levinger
- Enaim Medical Center Jerusalem and Tel Aviv, Tel Aviv, Israel
- Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Shalhevet Goldfeather Ben Zaken
- Enaim Medical Center Jerusalem and Tel Aviv, Tel Aviv, Israel
- Department of Ophthalmology, Kaplan Medical Center, Rehovot, Israel
| | - Dana Barequet
- Enaim Medical Center Jerusalem and Tel Aviv, Tel Aviv, Israel
- Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Irit Barequet
- Enaim Medical Center Jerusalem and Tel Aviv, Tel Aviv, Israel
- Goldschleger Eye Institute, Sheba Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Hashomer, Israel
| | - Asaf Achiron
- Enaim Medical Center Jerusalem and Tel Aviv, Tel Aviv, Israel
- Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Shmuel Levinger
- Enaim Medical Center Jerusalem and Tel Aviv, Tel Aviv, Israel
| |
Collapse
|
2
|
Ferreira A, Marta A, Baptista PM, Caiado F, Abreu AC, Maia S, Miranda V, Pinto MC, Parreira R, Menéres P. Refractive Surgery for Older Children and Adults with Accommodative Esotropia: A Systematic Review. Ophthalmic Res 2022; 65:361-376. [PMID: 35226900 DOI: 10.1159/000523816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 02/20/2022] [Indexed: 01/05/2023]
Abstract
INTRODUCTION Accommodative esotropia (AET) is characterized by an esodeviation of the eyes due to uncorrected hyperopia, deficient fusional divergence, or high accommodative convergence. Decreasing hyperopia would reduce accommodative convergence and strabismus. We sought to review the existing evidence regarding the outcomes of refractive surgery in patients with AET. METHODS A four-database search (Pubmed, ISI Web of Science, Cochrane, and Scopus) was performed from inception to March 2021 using the following MeSH terms: ("Refractive Surgical Procedures" OR "Keratomileusis, Laser In Situ" OR "Photorefractive Keratectomy" OR "Lens Implantation, Intraocular") AND ("Esotropia" OR "Accommodative Esotropia" OR "Refractive Esotropia" OR "Accommodative Strabismus"). No meta-analysis was performed due to studies' heterogeneity. RESULTS Twenty-eight studies including 22 case series enrolling 378 patients and 6 case reports enrolling 8 patients were selected among 185 original abstracts. In the case series, a total of 378 patients (726 eyes) were recruited with an age range of 8-52 years. All studies reported mean follow-up periods of at least 12 months. Photorefractive keratectomy was performed in 7 studies, laser-assisted in situ keratomileusis in 9 studies, laser-assisted sub-epithelial keratectomy was reported in 1 study, and 3 studies implanted intraocular lenses, including iris-fixated and collamer. Considering the adult patients with a preoperative corrected esodeviation ≤10 prism diopters (PD) (n = 129), all but 5 (3.9%) presented orthophoria or ≤10PD after refractive surgery. All children but 4 (4.5%) ended up with an esodeviation ≤10PD after surgery with those exceptions being in the range of 11-15PD. Six case reports were included in this review, comprising a total of 8 patients (16 eyes) with an age range of 7-34 years and a follow-up range of 4-48 months. Six case reports were included in this review, comprising a total of 8 patients (16 eyes) with an age range of 7-34 years and a follow-up range of 4-48 months. CONCLUSION Evidence produced so far points out that refractive surgery may be an alternative for spectacle correction for adults with AET ≤10PD. There is not enough evidence to recommend its use for patients under 18 years of age. The safety and predictability of these procedures for this purpose remains unclear as the selection criteria used for these patients are much different than the usual indications and there are no studies with long-term follow-up.
Collapse
Affiliation(s)
- André Ferreira
- Service of Ophthalmology, Centro Hospitalar Universitário do Porto, Porto, Portugal.,Unit of Anatomy, Department of Biomedicine, Faculty of Medicine of University of Porto, Porto, Portugal
| | - Ana Marta
- Service of Ophthalmology, Centro Hospitalar Universitário do Porto, Porto, Portugal
| | | | - Filipa Caiado
- Service of Ophthalmology, Centro Hospitalar Universitário do Porto, Porto, Portugal
| | - Ana Carolina Abreu
- Service of Ophthalmology, Centro Hospitalar Universitário do Porto, Porto, Portugal
| | - Sofia Maia
- Service of Ophthalmology, Centro Hospitalar Universitário do Porto, Porto, Portugal
| | - Vasco Miranda
- Service of Ophthalmology, Centro Hospitalar Universitário do Porto, Porto, Portugal.,Department of Ophthalmology, Instituto de Ciências Biomédicas Abel Salazar, University of Porto, Porto, Portugal
| | - Maria Céu Pinto
- Service of Ophthalmology, Centro Hospitalar Universitário do Porto, Porto, Portugal
| | - Ricardo Parreira
- Service of Ophthalmology, Centro Hospitalar Universitário do Porto, Porto, Portugal
| | - Pedro Menéres
- Service of Ophthalmology, Centro Hospitalar Universitário do Porto, Porto, Portugal.,Department of Ophthalmology, Instituto de Ciências Biomédicas Abel Salazar, University of Porto, Porto, Portugal
| |
Collapse
|
3
|
Jonker SMR, Berendschot TTJM, Saelens IEY, Bauer NJC, Nuijts RMMA. Phakic intraocular lenses: An overview. Indian J Ophthalmol 2020; 68:2779-2796. [PMID: 33229653 PMCID: PMC7856940 DOI: 10.4103/ijo.ijo_2995_20] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
Phakic intraocular lenses (pIOLs) are a common solution for the surgical correction of high myopia and myopia in thin corneas. Global trends result in increasing rates of patients with high myopia which will result in increased rates of pIOL implantation. Three types of lenses can be distinguished: anterior chamber angle-supported, anterior chamber iris-fixated, and posterior chamber phakic IOLs. The efficacy of phakic intraocular lenses is generally very good, but pIOLs have undergone many changes over the years to improve the safety profile and decrease pIOL-related complications such as endothelial cell loss, corneal decompensation and cataract formation. This article describes the efficacy and safety profiles of the most recent pIOLs, as well as suggests gaps of knowledge that are deserve additional research to optimize the results of pIOLs.
Collapse
Affiliation(s)
- Soraya M R Jonker
- University Eye Clinic Maastricht, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Tos T J M Berendschot
- University Eye Clinic Maastricht, Maastricht University Medical Center, Maastricht, The Netherlands
| | | | - Noël J C Bauer
- University Eye Clinic Maastricht, Maastricht University Medical Center, Maastricht; Department of Ophthalmology, Zuyderland Medical Center, Heerlen, The Netherlands
| | - Rudy M M A Nuijts
- University Eye Clinic Maastricht, Maastricht University Medical Center, Maastricht; Department of Ophthalmology, Zuyderland Medical Center, Heerlen, The Netherlands
| |
Collapse
|
4
|
Phakic intraocular lens implantation for the correction of hyperopia. J Cataract Refract Surg 2020; 45:1503-1511. [PMID: 31564323 DOI: 10.1016/j.jcrs.2019.05.051] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 05/20/2019] [Accepted: 05/25/2019] [Indexed: 11/27/2022]
Abstract
The prevalence of myopia is much higher than hyperopia. Hence, there are relatively few studies investigating phakic intraocular lens (pIOL) implantation for the correction of hyperopia. This review aimed to summarize the available relevant literature on the efficacy and safety of pIOL implantation for the correction of hyperopia and hyperopic astigmatism. At present, two types of pIOLs are used to correct hyperopia and hyperopic astigmatism: anterior chamber iris-fixated pIOLs and posterior chamber implantable collamer lenses. Both have been found to be safe and effective. No serious events (eg, retinal or choroidal detachment, endophthalmitis) were reported in the reviewed articles. Implantation of pIOLs might be the optimal refractive surgery for the correction of high hyperopia.
Collapse
|
5
|
Sidhu T, Desai A, Gagrani M, Dada T. Phacomorphic glaucoma in a high myope with phakic intraocular lens. BMJ Case Rep 2019; 12:12/2/e227096. [PMID: 30804159 DOI: 10.1136/bcr-2018-227096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
We report a case of a young, one-eyed woman with high myopia who presented to our emergency department with sudden onset painful diminution of vision in the right eye after undergoing laser treatment. Her right eye had a phakic intraocular lens (pIOL) implantation 4 years back and her left eye had absent light perception. She was diagnosed as right eye lens induced secondary angle closure glaucoma with pIOL touching the corneal endothelium and left eye atrophic bulbi. She was admitted under eye emergency for medical intraocular pressure control followed by pIOL explantation with lens aspiration of the cataractous lens and posterior chamber intraocular lens implantation.
Collapse
Affiliation(s)
- Talvir Sidhu
- Department of Ophthalmology, Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, Delhi, New Delhi, India
| | - Arjun Desai
- Department of Ophthalmology, Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, Delhi, New Delhi, India
| | - Meghal Gagrani
- Department of Ophthalmology, Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, Delhi, New Delhi, India
| | - Tanuj Dada
- Department of Ophthalmology, Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, Delhi, New Delhi, India
| |
Collapse
|
6
|
Coskunseven E, Kavadarli I, Sahin O, Kayhan B, Pallikaris I. Refractive Outcomes of 20 Eyes Undergoing ICL Implantation for Correction of Hyperopic Astigmatism. J Refract Surg 2017; 33:604-609. [DOI: 10.3928/1081597x-20170504-06] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2016] [Accepted: 04/18/2017] [Indexed: 11/20/2022]
|
7
|
|
8
|
Hashemi H, Khabazkhoob M, Asharlous A, Soroush S, Yekta A, Dadbin N, Fotouhi A. Cycloplegic autorefraction versus subjective refraction: the Tehran Eye Study. Br J Ophthalmol 2015; 100:1122-7. [PMID: 26541436 DOI: 10.1136/bjophthalmol-2015-307871] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2015] [Accepted: 10/15/2015] [Indexed: 11/04/2022]
Abstract
AIM To compare cycloplegic autorefraction with non-cycloplegic subjective refraction across all age and refractive error groups. METHODS In a cross-sectional study with random stratified cluster sampling, 160 clusters were chosen from various districts proportionate to the population of each district in Tehran. Following retinoscopy and autorefraction with the 0.25 D bracketing (Topcon KR-8000, Topcon, Tokyo, Japan), all participants had a subjective refraction. Then all participants underwent cycloplegic autorefraction. RESULTS The final analysis was performed on 3482 participants with a mean age of 31.7 years (range 5-92 years). Based on cycloplegic and subjective refraction, mean spherical equivalent (SE) was +0.31±1.80 and -0.32±1.61 D, respectively (p<0.001). The 95% limits of agreement (LoA) between these two types of refraction were from -0.40 to 1.70 D. The largest difference between these two types of refraction was seen in the age group of 5-10 years (1.11±0.60 D), and the smallest difference was in the age group of >70 years (0.34±0.45 D). The 95% LoA was -0.52 to 0.89 D in patients with myopia and -0.12 to 2.04 D in patients with hyperopia. We found that female gender (coefficients=0.048), older age (coefficients=-0.247), higher education (coefficients=-0.043) and cycloplegic SE (coefficients=-0.472) significantly correlated with lower intermethod differences. CONCLUSIONS The cycloplegic refraction is more sensitive than the subjective one to measure refractive error at all age groups especially in children and young adults. The cyclorefraction technique is highly recommended to exactly measure the refractive error in momentous conditions such as refractive surgery, epidemiological researches and amblyopia therapy, especially in hypermetropic eyes and paediatric cases.
Collapse
Affiliation(s)
- Hassan Hashemi
- Noor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran
| | - Mehdi Khabazkhoob
- Noor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran
| | - Amir Asharlous
- Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran
| | - Sara Soroush
- Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran
| | - AbbasAli Yekta
- Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Nooshin Dadbin
- Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran
| | - Akbar Fotouhi
- Department of Epidemiology and Biostatistics, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
9
|
Benda F, Filipová L, Filipec M. Correction of moderate to high hyperopia with an implantable collamer lens: medium-term results. J Refract Surg 2014; 30:526-33. [PMID: 25325893 DOI: 10.3928/1081597x-20140711-05] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2014] [Accepted: 05/12/2014] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the medium-term results of phakic posterior chamber implantable collamer lens implantation to correct moderate and high hyperopia. METHODS In this retrospective study, patients were treated for hyperopia with the Visian Implantable Collamer Lens (ICH model V3; STAAR Surgical AG, Nidau, Switzerland). Examined parameters were manifest refraction spherical equivalent, uncorrected distance visual acuity, corrected distance visual acuity, vault, anterior chamber depth, anterior chamber angle width, endothelial cell density, intraocular pressure, patient satisfaction, and complications. RESULTS The mean age of 15 patients (28 eyes) was 28 years (range: 18 to 36 years), with a mean follow-up period of 3.6 years (range: 3 to 6 years). The mean manifest refraction spherical equivalent decreased from +6.30 ± 1.42 diopters (D) (range: +4.25 to +8.50 D) preoperatively to -0.37 ± 0.56 D (range: -1.25 to +1.00 D) at 3 years postoperatively. The mean uncorrected distance visual acuity improved from 0.77 ± 0.38 logMAR (range: 0.16 to 1.30 logMAR) to 0.20 ± 0.17 logMAR (range: 0.00 to 0.48 logMAR) at the 3-year follow-up. Postoperatively, 62% of eyes gained one line of corrected distance visual acuity or remained unchanged. The mean vault reduced from 367.1 ± 253.6 μm (range: 70.0 to 1,190.0 μm) at 1 month postoperatively to 283.6 ± 210.0 μm (range: 75.0 to 915.0 μm) at the last follow-up visit (P = .005). The mean preoperative anterior chamber depth and anterior chamber angle width also decreased at the last follow-up visit (P = .037 and < .0001, respectively). The mean endothelial cell loss was 4.91% (P = .089). No serious complications occurred. Thirteen (87%) patients were satisfied with the outcomes and no patient was dissatisfied. CONCLUSIONS Implantation of a posterior chamber implantable collamer lens is a safe, effective, predictable, and stable method for the correction of moderate and high hyperopia in highly selected patients. No case of cataract or anterior subcapsular opacities formation was recorded in relation to the decrease of vault over the studied period and low vault in some eyes.
Collapse
|
10
|
Hua X, Yuan XY, Song H, Tang X. Long-term results of clear lens extraction combined with piggyback intraocular lens implantation to correct high hyperopia. Int J Ophthalmol 2013; 6:650-5. [PMID: 24195042 DOI: 10.3980/j.issn.2222-3959.2013.05.18] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2013] [Accepted: 09/13/2013] [Indexed: 11/02/2022] Open
Abstract
AIM To assess the refractive outcome of clear lensectomy combined with piggyback intraocular lens implantation in highly hyperopic patients. METHODS This case review included 19 eyes of 10 patients with high hyperopia and axial length less than 21mm. Intraocular lens power was calculated for emmetropia using the Holladay II formula in 17 eyes, and SRK/T formula in 2 eyes following clear lens extraction and piggyback intraocular lens implantation. Patients were examined periodically over 24 months for visual acuity and spherical equivalent (SE). RESULTS The mean postoperative SE at 24 months was 0.20±1.39D (range, -3.00 to 2.50D), better than preoperative 9.81±2.62D (range, +6.00 to +14.50D) (P<0.001). Five eyes had SE within ±0.5D of emmetropia and 11 eyes within ±1.00D at postoperative 24 months. The mean postoperative uncorrected visual acuity (UCVA) at 24 months was 0.60±0.36, significantly improved compared to preoperative 1.39±0.33 (P<0.001). The mean best-corrected visual acuity (BCVA) at 24 months was 0.49±0.35, not statistically different compared to preoperative 0.38±0.30 (P=0.34). Twelve eyes maintained and 1 gained 1 or more Snellen line of BCVA, 4 eyes lost 1 line, and 2 eyes lost 2 lines at 24 postoperative months. Twelve eyes best-corrected near visual acuity (BCNVA) achieved J1 at postoperative 24 months compared to preoperative 7 eyes and the other 7 eyes better than J3. CONCLUSION Clear lens extraction combined piggyback intraocular lens implantation appears to be an effective procedure to correct high hyperopia but mild overcorrection and intralenticular opacification may require secondary procedure.
Collapse
Affiliation(s)
- Xia Hua
- Tianjin Medical University, No.22 Qixiangtai Rd, Tianjin 300070, China ; Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Clinical College of Ophthalmology, Tianjin Medical University, No.4 Gansu Rd, Tianjin 300020, China ; Clinic Barraquer of Ophthalmology, C/Laforja 88, Barcelona 08021, Spain
| | | | | | | |
Collapse
|
11
|
Abstract
Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient's accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on the latter is very low, and some concerns still remain about its long-term safety. The present article reviews the published literature on the outcomes after PRL implantation in order to provide a general overview and evaluate its real potential as a surgical refractive option.
Collapse
|
12
|
Refractive surgery for accommodative esotropia: past, present, and future. Eur J Ophthalmol 2012; 22:871-7. [PMID: 23097019 DOI: 10.5301/ejo.5000210] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/04/2012] [Indexed: 11/20/2022]
Abstract
INTRODUCTION Refractive surgery has the potential to be a definitive treatment for accommodative esotropia, yet it has not been widely embraced. This article reviews the current literature on refractive surgery to treat accommodative esotropia. METHODS A literature search was performed using the following terms: refractive surgery, photorefractive keratectomy, laser-assisted keratomileusis, intraocular lens, hyperopia, accommodative esotropia, children, pediatric. RESULTS Fifteen series of patients treated with refractive surgery for accommodative esotropia were identified and summarized. CONCLUSIONS Refractive surgery holds promise for the treatment of accommodative esotropia, although treatment risks are present and additional investigation is needed.
Collapse
|
13
|
Hashemian SJ, Soleimani M, Foroutan A, Joshaghani M, Ghaempanah J, Jafari ME. Toric implantable collamer lens for high myopic astigmatism in keratoconic patients after six months. Clin Exp Optom 2012; 96:225-32. [PMID: 22963113 DOI: 10.1111/j.1444-0938.2012.00800.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2011] [Revised: 04/06/2012] [Accepted: 05/05/2012] [Indexed: 01/13/2023] Open
Abstract
BACKGROUND The aim was to evaluate the safety, efficacy, stability and predictability of posterior chamber collagen copolymer phakic intraocular lens (pIOL) implantation to correct myopia and myopic astigmatism associated with keratoconus. METHODS The unaided vision and visual acuity, refraction and adverse events were measured in 22 keratoconic eyes of 14 patients after using an implantable collamer lens (ICL) (STAAR Surgical Inc.) to correct refractive error. The outcome was evaluated over six months. RESULTS The mean pre-operative spherical equivalent (SE) and cylinder changed from -4.98 ± 2.63 DS and -2.77 ± 0.99 DC to -0.33 ± 0.51 DS and -1.23 ± 0.65 DC, respectively at the end of six months. Before the surgery the mean Snellen decimal visual acuity was 0.63 ± 0.20. The mean unaided vision and visual acuity changed to 0.76 ± 0.23 and 0.85 ± 0.21, respectively at the end of six months. The mean safety and efficacy indices were 1.40 ± 0.32 and 1.24 ± 0.34, respectively. No eye lost a line of visual acuity and 17 eyes (77.3 per cent) gained one or more lines. Fifteen eyes (68.2 per cent) were within 0.50 D and 20 (90.9 per cent) were within 1.00 D of the desired spherical equivalent refraction. There was a change in manifest refraction of 0.09 ± 0.21 (ranging from -0.25 to +0.75) from one week to six months after the surgery. CONCLUSION The clinical outcomes of the current study demonstrate the safety, efficacy and predictability of toric implantable collamer lens in the correction of myopia and myopic astigmatism associated with keratoconus. The patients' refractions achieved early stability and remained stable during the course of the study.
Collapse
Affiliation(s)
- Seyed Javad Hashemian
- Eye Research Center, Rassoul Akram Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | | | | | | | | | | |
Collapse
|
14
|
Kohnen T, Kook D, Morral M, Güell JL. Phakic intraocular lenses. J Cataract Refract Surg 2010; 36:2168-94. [DOI: 10.1016/j.jcrs.2010.10.007] [Citation(s) in RCA: 141] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2010] [Revised: 09/01/2010] [Accepted: 09/01/2010] [Indexed: 11/29/2022]
|