1
|
Sahay P, Bafna RK, Reddy JC, Vajpayee RB, Sharma N. Complications of laser-assisted in situ keratomileusis. Indian J Ophthalmol 2021; 69:1658-1669. [PMID: 34146007 PMCID: PMC8374806 DOI: 10.4103/ijo.ijo_1872_20] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2020] [Revised: 07/19/2020] [Accepted: 10/27/2020] [Indexed: 11/25/2022] Open
Abstract
Laser-assisted in situ keratomileusis (LASIK) is one of the most commonly performed kerato-refractive surgery globally. Since its introduction in 1990, there has been a constant evolution in its technology to improve the visual outcome. The safety, efficacy, and predictability of LASIK are well known, but complications with this procedure, although rare, are not unknown. Literature review suggests that intraoperative complications include suction loss, free cap, flap tear, buttonhole flap, decentered ablation, central island, interface debris, femtosecond laser-related complications, and others. The postoperative complications include flap striae, flap dislocation, residual refractive error, diffuse lamellar keratitis, microbial keratitis, epithelial ingrowth, refractive regression, corneal ectasia, and others. This review aims to provide a comprehensive knowledge of risk factors, clinical features, and management protocol of all the reported complications of LASIK. This knowledge will help in prevention as well as early identification and timely intervention with the appropriate strategy for achieving optimal visual outcome even in the face of complications.
Collapse
Affiliation(s)
- Pranita Sahay
- Department of Ophthalmology, Lady Hardinge Medical College, New Delhi, India
| | - Rahul Kumar Bafna
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Jagadesh C Reddy
- Cataract and Refractive Surgery Services, Cornea Institute, L V Prasad Eye Institute, L V Prasad Marg, Roan No-2, Banjara Hills, Hyderabad, Telangana, India
| | - Rasik B Vajpayee
- Vision Eye Institute, Royal Victorian Eye and Ear Hospital, University of Melbourne, Melbourne, Australia
| | - Namrata Sharma
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|
2
|
Hirabayashi KE, Manche EE. Hydrogel sealant to prevent recurrent epithelial ingrowth in the setting of a LASIK flap buttonhole. Am J Ophthalmol Case Rep 2019; 15:100518. [PMID: 31372580 PMCID: PMC6656928 DOI: 10.1016/j.ajoc.2019.100518] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2018] [Revised: 06/14/2019] [Accepted: 07/15/2019] [Indexed: 11/17/2022] Open
Abstract
Purpose To report the first case of hydrogel sealant to prevent the recurrence of epithelial ingrowth in a LASIK flap buttonhole. Observations A 67-year-old female presented ten years after undergoing bilateral LASIK with diffuse lamellar keratitis and flap dislodgement after blunt trauma to the right eye. She was found to have epithelial ingrowth with diffuse debris and striae, so her flap was lifted and the epithelial ingrowth was removed. However, a central buttonhole was noted intraoperatively. Once all the epithelium was removed, the flap was repositioned and hydrogel sealant (ReSure, Ocular Therapeutix, Bedford, MA) was used to fill the buttonhole as well as seal down the edges of the flap. Sixteen months postoperatively, the patient's uncorrected visual acuity was 20/50-2 and there was no recurrence of the epithelial ingrowth at the edges of the buttonhole. Conclusions and importance Preventing the recurrence of epithelial ingrowth is a challenging situation, especially in the setting of a LASIK flap buttonhole. The use of hydrogel sealant in the buttonhole and around the edges of the flap may offer an elegant and effective solution.
Collapse
Affiliation(s)
- Kristin E Hirabayashi
- Department of Ophthalmology, Stanford University, Byers Eye Institute, 2452 Watson Ct, Palo Alto, CA, 94303, USA
| | - Edward E Manche
- Department of Ophthalmology, Stanford University, Byers Eye Institute, 2452 Watson Ct, Palo Alto, CA, 94303, USA
| |
Collapse
|
3
|
Hammer T, Höche T, Heichel J. [Scanning electron microscopic investigations of cutting edge quality in lamellar keratotomy using the Wavelight femtosecond laser (FS-200) : What influence do spot distance and an additional tunnel have?]. Ophthalmologe 2017; 115:47-54. [PMID: 28741162 DOI: 10.1007/s00347-017-0544-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Femtosecond lasers (fs-lasers) are established cutting instruments for the creation of LASIK flaps. Previous studies often showed even rougher surfaces after application of fs-laser systems compared to lamellar keratotomy with mechanical microkeratomes. When cutting the cornea with fs-lasers, an intrastromal gas development occurs, which has a potentially negative influence on the cutting quality if the gas cannot be dissipated; therefore, manufacturers have chosen the way of gas assimilation in so-called pockets. The investigated system creates a tunnel which opens under the conjunctiva. The aim of this study was to investigate the effects of a tunnel as well as the influence of different spot distances on the quality of cut surfaces and edges. MATERIAL AND METHODS In this experimental study on freshly enucleated porcine eyes (n = 15), the following cuts were carried out with the FS-200 (Wavelight, Erlangen, Germany): 1. standard setting (spot and line separation 8 µm), 2. with tunnel for gas drainage, 3. without gas-conducting tunnel, 4. with increased spot spacing (spot and line separation 9 μm instead of 8 μm) and 5. with reduced spot spacing (spot and line separation 7 μm instead of 8 μm). Subsequently, scanning electron microscopy (FEI Quanta 650, Hillsboro, OR) of the cut edges and surfaces as well as the gas drain tunnel were performed. The evaluation was based on an established score. RESULTS The current fs-laser system (200 Hz) is able to create smooth cutting surfaces and sharp edges. The changed density of laser pulses compared to the standard settings with a reduced or increased distance between the pulses, did not achieve any further improvement in the surface quality. The gas-conducting tunnel could be detected by scanning electron microscope. In the case of cutting without a tunnel, roughened surfaces and irregularities on the cutting edges were found. CONCLUSION When the FS-200 fs-laser is used, LASIK cuts with very smooth cut surfaces and sharp cutting edges are achieved. This is only valid as long as an additional tunnel with the fs-laser is placed under the conjunctiva. It can be assumed that the resulting gas is effectively drained through this tunnel. The installation of the tunnel represents a new possibility to replace previous techniques of gas assimilation in deeper lying cutting areas.
Collapse
Affiliation(s)
- T Hammer
- Augenzentrum "Frohe Zukunft", Dessauer Str. 194, 06118, Halle (Saale), Deutschland.
- Klinik und Poliklinik für Augenheilkunde, Universitätsklinikum Halle (Saale), Halle (Saale), Deutschland.
| | - T Höche
- Fraunhofer Institut für Mikrostruktur von Werkstoffen und Systemen, Halle (Saale), Deutschland
| | - J Heichel
- Klinik und Poliklinik für Augenheilkunde, Universitätsklinikum Halle (Saale), Halle (Saale), Deutschland
| |
Collapse
|
4
|
Fu D, Zhang ZY, Wang L, Zhou XT, Yu ZQ. Refractive Regression and Changes in Central Corneal Thickness Three Years after Laser-Assisted Subepithelial Keratectomy for High Myopia in Eyes with Thin Corneas: A Retrospective Study. Semin Ophthalmol 2016; 32:631-641. [PMID: 27367533 DOI: 10.3109/08820538.2016.1142579] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Affiliation(s)
- Dan Fu
- Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, PR China
| | - Zhen-Yong Zhang
- Department of Ophthalmology, Shanghai University of Traditional Chinese Medicine, Shanghai, PR China
| | - Lin Wang
- Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, PR China
| | - Xing-Tao Zhou
- Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, PR China
- Key Laboratory of Myopia, Ministry of Health, Shanghai, PR China
| | - Zhi-Qiang Yu
- Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, PR China
- Key Laboratory of Myopia, Ministry of Health, Shanghai, PR China
| |
Collapse
|
5
|
|
6
|
Kozomara B, Bohac M, Gabric N, Patel S. Bowman strip complications during routine LASIK: Two cases demonstrating the clinical advantage of using Mitomicyn C in such cases. JOURNAL OF OPTOMETRY 2015; 8:219-220. [PMID: 25130067 PMCID: PMC4502225 DOI: 10.1016/j.optom.2014.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Revised: 07/04/2014] [Indexed: 06/03/2023]
Affiliation(s)
- Bojan Kozomara
- Svjetlost Eye Hospital, Banja Luka, Bosnia and Herzegovina.
| | - Maja Bohac
- Svjetlost University Eye Hospital, Zagreb, Croatia
| | | | - Sudi Patel
- Svjetlost University Eye Hospital, Zagreb, Croatia; NHS National Services Scotland, Edinburgh, UK
| |
Collapse
|
7
|
Fibrin glue for prevention of recurrent epithelial ingrowth under a LASIK flap with a central buttonhole defect. J Cataract Refract Surg 2013; 38:1857-60. [PMID: 22999605 DOI: 10.1016/j.jcrs.2012.08.031] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2012] [Revised: 03/21/2012] [Accepted: 03/21/2012] [Indexed: 11/20/2022]
Abstract
A 61-year-old woman presented with a paracentral buttonhole flap defect associated with a linear tear, extensive epithelial ingrowth, and macrostriae in the right eye. A laser in situ keratomileusis enhancement had been performed 3 weeks earlier. The epithelial ingrowth was removed after careful lifting of the flap, and tissue adhesive was used postoperatively as a barrier to further ingrowth. Six months postoperatively, the patient's corrected distance visual acuity had improved to 20/20 and the slitlamp examination showed no evidence of recurrent epithelial ingrowth. This case presents a novel approach to the management of a buttonhole defect.
Collapse
|
8
|
Tomita M, Waring GO, Watabe M. Analysis of corneal endothelial cell density and morphology after laser in situ keratomileusis using two types of femtosecond lasers. Clin Ophthalmol 2012; 6:1567-72. [PMID: 23055680 PMCID: PMC3460709 DOI: 10.2147/opth.s35887] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose To compare two different femtosecond lasers used for flap creation during laser-assisted in situ keratomileusis (LASIK) surgery in terms of their effects on the corneal endothelium. Methods We performed LASIK surgery on 254 eyes of 131 patients using IntraLase FS60 (Abbott Medical Optics, Inc, Irvine, CA; IntraLase group) and 254 eyes of 136 patients using Femto LDV (Ziemer Group AG, Port, Switzerland; LDV group) for corneal flap creation. The mean cell density, coefficient of variation, and hexagonality of the corneal endothelial cells were determined and the results were statistically compared. Results There were no statistically significant differences in the corneal morphology between pre and post LASIK results in each group, nor were there significant differences between the results of both groups at 3 months post LASIK. Conclusions Both IntraLase FS60 and Ziemer Femto LDV are able to create flaps without significant adverse effects on the corneal endothelial morphology through 3 months after LASIK surgery.
Collapse
Affiliation(s)
- Minoru Tomita
- Shinagawa LASIK Center, Chiyoda-ku, Tokyo, Japan ; Department of Ophthalmology, Wenzhou Medical College, Wenzhou, China
| | | | | |
Collapse
|
9
|
Bromley JG, Albright TD, Kharod-Dholakia B, Kim JY. Intraoperative and postoperative complications of laser in situkeratomileusis. EXPERT REVIEW OF OPHTHALMOLOGY 2012. [DOI: 10.1586/eop.12.2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
10
|
Tomita M, Watabe M, Nakamura T, Nakamura N, Tsuru T, Waring GO. Management and Outcomes of Suction Loss During LASIK Flap Creation With a Femtosecond Laser. J Refract Surg 2012; 28:32-6. [DOI: 10.3928/1081597x-20111122-01] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2010] [Accepted: 10/11/2011] [Indexed: 11/20/2022]
|
11
|
Zhang ZH, Jin HY, Suo Y, Patel SV, Montés-Micó R, Manche EE, Xu X. Femtosecond laser versus mechanical microkeratome laser in situ keratomileusis for myopia: Metaanalysis of randomized controlled trials. J Cataract Refract Surg 2011; 37:2151-9. [DOI: 10.1016/j.jcrs.2011.05.043] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2010] [Revised: 05/18/2011] [Accepted: 05/23/2011] [Indexed: 10/15/2022]
|
12
|
Yao P, Xu Y, Zhou X. Comparison of the predictability, uniformity and stability of a laser in situ keratomileusis corneal flap created with a VisuMax femtosecond laser or a Moria microkeratome. J Int Med Res 2011; 39:748-58. [PMID: 21819705 DOI: 10.1177/147323001103900306] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
This prospective study compared the predictability, uniformity and stability of laser in situ keratomileusis corneal flap thickness created by a femtosecond laser or a classic microkeratome. Twenty-five femtosecond laser (VisuMax, Carl Zeiss Meditec) flaps and 38 microkeratome (Moria M3) flaps were measured using anterior segment optical coherence tomography at 1 week, 1 month and 6 months postoperatively. Flap thickness at seven points on each of the four meridians was calculated. At 6 months, VisuMax flaps showed better prediction than Moria flaps for central flap thickness. The standard deviation within individual flaps was smaller for VisuMax flaps and their index of symmetry was better. The mean thicknesses among the four eccentricities in the VisuMax flaps were the same, while Moria flaps were thicker at the 3-mm radius compared with the centre. The VisuMax femtosecond laser created corneal flaps with better predictability and uniformity, and similar reproducibility and stability, compared with the microkeratome.
Collapse
Affiliation(s)
- P Yao
- Myopia Key Laboratory of the Health Ministry, Eye and ENT Hospital of Fudan University, Shanghai, China
| | | | | |
Collapse
|
13
|
Al-Mezaine HS, Al-Amro SA, Al-Obeidan S. Intraoperative flap complications in laser in situ keratomileusis with two types of microkeratomes. Saudi J Ophthalmol 2011; 25:239-43. [PMID: 23960931 DOI: 10.1016/j.sjopt.2011.04.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2011] [Accepted: 04/05/2011] [Indexed: 10/18/2022] Open
Abstract
PURPOSE To determine the incidence and types of intraoperative flap complications in laser in situ keratomileusis (LASIK) encountered with the Hansatome microkeratome and the Moria microkeratome. METHODS In this retrospective case series, all patients with intraoperative flap complications who were treated between June 1999 and July 2008 at the Eye Consultants Center in Riyadh, Saudi Arabia, were identified and reviewed. RESULTS Of the 4352 subjects who underwent bilateral primary LASIK procedure, intraoperative microkeratome complications were detected in 89 eyes of 83 patients. The overall incidence of flap complications was 89/8704 (1.00%): incomplete flaps occurred in 53 eyes (0.60%), followed by buttonhole flaps in 17 eyes (0.19%), free complete flaps in 10 eyes (0.11%), free partial flaps in 6 eyes (0.07%), sluffed epithelium in 2 eyes (0.023%), and a splitted flap (vertical flap cut) in 1 eye (0.01%). The incidence rates of intraoperative flap complications with the Hansatome microkeratome and the Moria microkeratome were 1.21% (41/3378) and 0.90% (48/5326), respectively (P = 0.19). There was a statistically significant difference between the two microkeratomes with regard to the incidence of buttonhole flaps: 0.33% (11/3378) for the Hansatome microkeratome versus 0.11% (6/5326) for the Moria microkeratome (P = 0.04). CONCLUSION Generally, the incidence rates of intraoperative flap complications with the Hansatome microkeratome and the Moria microkeratome were similar. However, buttonhole flaps occurred more often with the Hansatome microkeratome (a type of microkeratome that produces larger flaps). The commonest complication encountered was the incomplete flap, followed by the buttonhole flap and free flap.
Collapse
Affiliation(s)
- Hani S Al-Mezaine
- Department of Ophthalmology, College of Medicine, King Saud University, Riyadh, Saudi Arabia
| | | | | |
Collapse
|
14
|
Reinstein DZ, Archer TJ, Gobbe M. LASIK Flap Thickness Profile and Reproducibility of the Standard vs Zero Compression Hansatome Microkeratomes: Three-Dimensional Display with Artemis VHF Digital Ultrasound. J Refract Surg 2011; 27:417-26. [DOI: 10.3928/1081597x-20101110-01] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2010] [Accepted: 09/15/2010] [Indexed: 11/20/2022]
|
15
|
|
16
|
Rocha G. September consultation #2. J Cataract Refract Surg 2009. [DOI: 10.1016/j.jcrs.2009.06.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|