1
|
Ungricht EL, Culp C, Qu P, Jensen N, Harris JT, Brintz BJ, Mamalis N, Olson RJ, Werner L. Effect of longitudinal and torsional ultrasound on corneal endothelial cells: experimental study in rabbit eyes. J Cataract Refract Surg 2022; 48:349-354. [PMID: 34224479 PMCID: PMC8712615 DOI: 10.1097/j.jcrs.0000000000000737] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 06/22/2021] [Indexed: 12/30/2022]
Abstract
PURPOSE To compare corneal endothelial damage from longitudinal and torsional ultrasound during phacoemulsification. SETTING John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. DESIGN Experimental study. METHODS 9 New Zealand white rabbits underwent bilateral surgery. After incision, the Intrepid Balanced Tip of the Centurion Ozil handpiece was inserted into the anterior chamber, and the following settings were used: 50 mL/min flow, 70 mm Hg intraocular pressure, 600 mm Hg vacuum, and 60% longitudinal (1 eye) or torsional (contralateral eye) ultrasound for 30 seconds. Cumulative dissipated energy (CDE) was noted. After euthanasia and enucleation, the corneas were removed, stained with trypan blue/alizarin red, and photographed (400× photographs from 5 specific areas and 1 overview photograph from each corneal button). The ImageJ program was used to evaluate cell damage and loss in the photographs obtained from each cornea. RESULTS Cavitation bubbles around the phacoemulsification tip were generally observed in the longitudinal group. CDE was 17.4 ± 0.58 and 6.93 ± 0.15 in the longitudinal and torsional groups, respectively (P = .003). The percentage of intact cells was statistically higher in the torsional group (94.22% ± 5.99% vs 56.85% ± 22.29%), and the percentage of lost cells was statistically higher in the longitudinal group (42.10% ± 22.02% vs 4.97% ± 6.23%) (P = .003). This was observed in the analysis of the 400× photographs and the overview photographs. CONCLUSIONS This study suggests that torsional ultrasound was associated with significantly less corneal endothelial cell damage than classical longitudinal tip motion, providing further insight on mechanisms of corneal endothelial damage during phacoemulsification.
Collapse
Affiliation(s)
- Emilie L. Ungricht
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
- From the University of Utah, School of Medicine, Salt Lake City, UT, USA
| | - Catherine Culp
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
| | - Phillip Qu
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
| | - Nathan Jensen
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
- From the University of Utah, School of Medicine, Salt Lake City, UT, USA
| | - Jacob T. Harris
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
- From the University of Utah, School of Medicine, Salt Lake City, UT, USA
| | - Ben J. Brintz
- From the Division of Epidemiology, Department of Internal Medicine, University of Utah, Salt Lake City, UT, USA
| | - Nick Mamalis
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
| | - Randall J. Olson
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
| | - Liliana Werner
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
2
|
Pahlitzsch M, Pahlitzsch ML, Sumarni U, Pahlitzsch T. Can we improve the efficacy of modern cataract surgery by using different tip designs? A comparison of balanced and tapered tip in femtosecond laser-assisted cataract surgery and manual phacoemulsification. Clin Exp Ophthalmol 2017; 46:35-45. [DOI: 10.1111/ceo.12998] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Revised: 05/22/2017] [Accepted: 05/23/2017] [Indexed: 12/12/2022]
Affiliation(s)
| | - Marie-Luise Pahlitzsch
- Department of Ophthalmology; University Clinic Frankfurt/Main; Frankfurt am Main Germany
| | | | | |
Collapse
|
3
|
Noh JH, Jung MS. Comparison of Clinical Outcomes between Torsional and Longitudinal Phacoemulsification. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2015. [DOI: 10.3341/jkos.2015.56.7.1028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Ju Hee Noh
- Department of Ophthalmology, Cheonan Hospital, Soonchunhyang University College of Medicine, Cheonan, Korea
| | - Moon Sun Jung
- Department of Ophthalmology, Cheonan Hospital, Soonchunhyang University College of Medicine, Cheonan, Korea
| |
Collapse
|
4
|
Fluid dynamics, cavitation, and tip-to-tissue interaction of longitudinal and torsional ultrasound modes during phacoemulsification. J Cataract Refract Surg 2013; 39:611-6. [DOI: 10.1016/j.jcrs.2012.10.050] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2012] [Revised: 10/16/2012] [Accepted: 10/21/2012] [Indexed: 11/20/2022]
|
5
|
Intraoperative performance and postoperative outcome comparison of longitudinal, torsional, and transversal phacoemulsification machines. J Cataract Refract Surg 2012; 38:234-41. [DOI: 10.1016/j.jcrs.2011.08.035] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2011] [Revised: 08/21/2011] [Accepted: 08/23/2011] [Indexed: 11/20/2022]
|
6
|
Aust SD, Terry S, Hebdon T, Gunderson B, Terry M, Dimalanta R. Determining the local origin of hydroxyl radical generation during phacoemulsification. J Cataract Refract Surg 2011; 37:1154-9. [PMID: 21596259 DOI: 10.1016/j.jcrs.2010.12.055] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2010] [Revised: 12/08/2010] [Accepted: 12/10/2010] [Indexed: 10/18/2022]
Abstract
PURPOSE To determine the local origin of hydroxyl radicals during phacoemulsification using an ultrasonic phacoemulsification device that includes longitudinal and torsional modalities. SETTING Chemistry and Biochemistry Department, Utah State University, Logan, Utah, USA. DESIGN Experimental study. METHODS Experiments were conducted using the Infiniti Vision System and Ozil handpiece. Hydroxyl radical concentrations during longitudinal and torsional phacoemulsification were quantitated as malondialdehyde (MDA) determined spectrophotometrically using the deoxyribose assay. The difference between the total concentration found in the aspirated solution at steady-state concentrations and the pre-aspirate levels deductively determined the concentration of MDA formed along the interior of the sonicating tip. The time to reach 50% of steady state as a function of reaction vessel volume was determined. RESULTS The mean maximum for torsional ultrasound at 100% amplitude was 7.70 nM ± 0.38 (SD), 91.1% of which was generated outside the tip. During longitudinal ultrasound at 100% power, MDA concentration in the aspirated solution was 29.5 ± 0.3 nM, 71.6% of which was generated outside the tip. The time (seconds) to reach 50% of maximum for longitudinal ultrasound using 5 mL, 10 mL, and 20 mL reaction vessels was 12.6 ± 1.5, 21.0 ± 1.5, and 25.3 ± 3.4, respectively. CONCLUSION Although a significantly greater proportion of the hydroxyl radicals generated during ultrasound modality were formed outside the phaco tip (91.1% torsional; 71.6% longitudinal), torsional ultrasound generated only about one-fourth the amount of MDA as longitudinal ultrasound in total and about one-third that generated outside the tip (7.02 nM versus 21.1 nM). FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes.
Collapse
Affiliation(s)
- Steven D Aust
- Department of Chemistry and Biochemistry, Utah State University, Logan, Utah, USA
| | | | | | | | | | | |
Collapse
|