• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4619893)   Today's Articles (1659)   Subscriber (49405)
For: Sanders DR, Sarver EJ, Cooke DL. Accuracy and precision of a new system for measuring toric intraocular lens axis rotation. J Cataract Refract Surg 2014;39:1190-5. [PMID: 23889866 DOI: 10.1016/j.jcrs.2013.06.006] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2013] [Revised: 03/19/2013] [Accepted: 03/20/2013] [Indexed: 11/26/2022]
Number Cited by Other Article(s)
1
Ullrich M, Fisus AD, Palkovits S, Hienert J, Hirnschall N, Findl O. Rotational stability and capsular bag performance of a hydrophobic acrylic open-loop single-piece intraocular lens. Eur J Ophthalmol 2024:11206721241234393. [PMID: 38389411 DOI: 10.1177/11206721241234393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2024]
2
Georgiev S, Kumar A, Findl O, Hirnschall N, Niederleithner M, Kendrisic M, Drexler W, Leitgeb RA. Digital ocular swept source optical coherence aberrometry. BIOMEDICAL OPTICS EXPRESS 2021;12:6762-6779. [PMID: 34858679 PMCID: PMC8606149 DOI: 10.1364/boe.430596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 08/09/2021] [Accepted: 08/11/2021] [Indexed: 06/13/2023]
3
Bhogal-Bhamra GK, Sheppard AL, Kolli S, Wolffsohn JS. Rotational Stability and Centration of a New Toric Lens Design Platform Using Objective Image Analysis Over 6 Months. J Refract Surg 2019;35:48-53. [DOI: 10.3928/1081597x-20181204-01] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Accepted: 11/26/2018] [Indexed: 11/20/2022]
4
Holladay JT, Pettit G. Improving toric intraocular lens calculations using total surgically induced astigmatism for a 2.5 mm temporal incision. J Cataract Refract Surg 2018;45:272-283. [PMID: 30527793 DOI: 10.1016/j.jcrs.2018.09.028] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 08/27/2018] [Accepted: 09/27/2018] [Indexed: 10/27/2022]
5
Schartmüller D, Schriefl S, Schwarzenbacher L, Leydolt C, Menapace R. True rotational stability of a single-piece hydrophobic intraocular lens. Br J Ophthalmol 2018;103:186-190. [PMID: 29666120 DOI: 10.1136/bjophthalmol-2017-311797] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2017] [Revised: 02/16/2018] [Accepted: 03/29/2018] [Indexed: 01/19/2023]
6
Hida WT, Tzelikis PF, Vilar C, Chaves MAPD, Motta AFP, Carricondo PC, Ventura BV, Ambrosio R, Nosé W, Alves MR. Outcomes study between femtosecond laser-assisted cataract surgery and conventional phacoemulsification surgery using an active fluidics system. Clin Ophthalmol 2017;11:1735-1739. [PMID: 29026283 PMCID: PMC5627560 DOI: 10.2147/opth.s136136] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]  Open
7
Kanellopoulos AJ, Asimellis G. Standard manual capsulorhexis / Ultrasound phacoemulsification compared to femtosecond laser-assisted capsulorhexis and lens fragmentation in clear cornea small incision cataract surgery. EYE AND VISION 2016;3:20. [PMID: 27478858 PMCID: PMC4967293 DOI: 10.1186/s40662-016-0050-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2015] [Accepted: 06/25/2016] [Indexed: 01/19/2023]
8
Kirwan C, Nolan JM, Stack J, Dooley I, Moore J, Moore TC, Beatty S. Introduction of a Toric Intraocular Lens to a Non-Refractive Cataract Practice: Challenges and Outcomes. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY AND CLINICAL RESEARCH 2016;3. [PMID: 27830188 DOI: 10.23937/2378-346x/1410056] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
9
Zhang B, Ma JX, Liu DY, Du YH, Guo CR, Cui YX. Optical performance of toric intraocular lenses in the presence of decentration. Int J Ophthalmol 2015;8:730-5. [PMID: 26309871 DOI: 10.3980/j.issn.2222-3959.2015.04.16] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2014] [Accepted: 11/03/2014] [Indexed: 12/18/2022]  Open
10
Mosquera SA, Verma S. Effects of torsional movements in refractive procedures. J Cataract Refract Surg 2015;41:1752-66. [DOI: 10.1016/j.jcrs.2015.07.017] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2014] [Revised: 01/13/2015] [Accepted: 01/14/2015] [Indexed: 11/26/2022]
11
Bissen-Miyajima H, Negishi K, Hieda O, Kinoshita S. Microincision Hydrophobic Acrylic Aspheric Toric Intraocular Lens for Astigmatism and Cataract Correction. J Refract Surg 2015;31:358-64. [DOI: 10.3928/1081597x-20150521-01] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2014] [Accepted: 04/02/2015] [Indexed: 11/20/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA