1
|
Wolffsohn JS, Naroo SA, Bullimore MA, Craig JP, Davies LN, Markoulli M, Schnider C, Morgan PB. BCLA CLEAR Presbyopia: Definitions. Cont Lens Anterior Eye 2024; 47:102155. [PMID: 38609792 DOI: 10.1016/j.clae.2024.102155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/14/2024]
Abstract
Presbyopia is often the first sign of ageing experienced by humans. Standardising terminology and adopting it across the BCLA CLEAR Presbyopia reports, improves consistency in the communication of the evidence-based understanding of this universal physiological process. Presbyopia can be functionally and psychologically debilitating, especially for those with poor access to eyecare. Presbyopia was defined as occurring when the physiologically normal age-related reduction in the eye's focusing range reaches a point that, when optimally corrected for far vision, the clarity of vision at near is insufficient to satisfy an individual's requirements. Accommodation is the change in optical power of the eye due to a change in crystalline lens shape and position, whereas pseudo-accommodation is the attainment of functional near vision in an emmetropic or far-corrected eye without changing the refractive power of the eye. Other definitions specific to vision and lenses for presbyopia were also defined. It is recommended that these definitions be consistently adopted in order to standardise future research, clinical evaluations and education.
Collapse
Affiliation(s)
- James S Wolffsohn
- College of Health & Life Sciences, Aston University, Birmingham, United Kingdom.
| | - Shehzad A Naroo
- College of Health & Life Sciences, Aston University, Birmingham, United Kingdom
| | | | - Jennifer P Craig
- Department of Ophthalmology, The University of Auckland, Auckland, New Zealand
| | - Leon N Davies
- College of Health & Life Sciences, Aston University, Birmingham, United Kingdom
| | - Maria Markoulli
- School of Optometry & Vision Science, University of New South Wales, Sydney, Australia
| | - Cristina Schnider
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, United Kingdom
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, United Kingdom
| |
Collapse
|
2
|
Fernandez-Bueno I, Olcina LI, Andrés-Iglesias C, Puertas-Neyra K, Fernández-Martínez I, Usategui-Martín R, Maldonado-López MJ. Safety, biocompatibility, and potential functionality of a new accommodative intraocular lens: An experimental study in rabbits. Heliyon 2023; 9:e19604. [PMID: 37810139 PMCID: PMC10558835 DOI: 10.1016/j.heliyon.2023.e19604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 08/21/2023] [Accepted: 08/28/2023] [Indexed: 10/10/2023] Open
Abstract
This study aims to evaluate the safety, biocompatibility, and functionality of a new accommodative intraocular lens (IOL) (LUZ, patent PCT/ES2016/070,813) after implantation in rabbit eyes. LUZ (Study) and EyeCee® plus a capsular ring (Control) were implanted in rabbits (n = 8 each) after phacoemulsification. Intraoperative follow-up, long-term clinical follow-up, and functional IOL studies were carried out periodically for up to 180 days. A macroscopic examination of the eyeballs to reveal abnormalities and determine the implant centering and a microscopic examination to semi-quantify cell and tissue response were performed. Statistical analysis of the collected data was finally achieved. During follow-up, no significant changes in the general condition nor the clinical evaluation were observed between both groups. However, Study IOL remained centered throughout the study and did not present severe complications as observed in the Control group. Functional studies did not reveal significant differences between both materials. Study showed better centering, fewer adhesions, and maintenance of an opening capsular bag compared to the Control. Local biological effects caused by Study implantation are minimal and comparable to the Control. Therefore, LUZ showed no clinical signs or histological response of adverse reaction to the implanted material, according to UNE-EN ISO 11979-5 and 10993-6. Functionality must be confirmed in another animal species with greater lens accommodation capacity than the rabbit. LUZ keeps the capsular bag open, favoring its centering and avoiding fibrosis and adherence to the bag; this allows potential accommodation of this IOL and theoretically enables the patient to focus dynamically.
Collapse
Affiliation(s)
- Ivan Fernandez-Bueno
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Retina Group, Universidad de Valladolid, 47011 Valladolid, Spain
- RICORS Inflamación e inmunopatología de órganos y sistemas (RD21/0002/0017), National Institute of Health Carlos III, Madrid, Spain
| | | | - Cristina Andrés-Iglesias
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Retina Group, Universidad de Valladolid, 47011 Valladolid, Spain
| | - Kevin Puertas-Neyra
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Retina Group, Universidad de Valladolid, 47011 Valladolid, Spain
| | - Itziar Fernández-Martínez
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Retina Group, Universidad de Valladolid, 47011 Valladolid, Spain
- CIBER BBN, National Institute of Health Carlos III, Madrid, Spain
| | - Ricardo Usategui-Martín
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Retina Group, Universidad de Valladolid, 47011 Valladolid, Spain
- RICORS Inflamación e inmunopatología de órganos y sistemas (RD21/0002/0017), National Institute of Health Carlos III, Madrid, Spain
- Departamento de Biología Celular, Histología y Farmacología, Universidad de Valladolid, 47005 Valladolid, Spain
| | - Miguel José Maldonado-López
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Retina Group, Universidad de Valladolid, 47011 Valladolid, Spain
- RICORS Inflamación e inmunopatología de órganos y sistemas (RD21/0002/0017), National Institute of Health Carlos III, Madrid, Spain
| |
Collapse
|
3
|
Current Advances and Future of Premium IOLs. CURRENT SURGERY REPORTS 2022. [DOI: 10.1007/s40137-022-00333-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
4
|
Zhu Y, Zhong Y, Fu Y. The effects of premium intraocular lenses on presbyopia treatments. ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH 2022; 2:100042. [PMID: 37846220 PMCID: PMC10577869 DOI: 10.1016/j.aopr.2022.100042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 01/28/2022] [Accepted: 02/20/2022] [Indexed: 10/18/2023]
Abstract
Background Presbyopia has become a global disease affecting the world's aging population. Among various treatments, cataract extraction and intraocular lens (IOL) implantation have become the most popular and common methods of presbyopia correction. During the twentieth century, IOLs have underwent significant innovation and advancements to meet the patients' high demands for functional vision at all distances. Main Text To meet the increasing needs for excellent near and intermediate vision for daily activities, some premium IOLs with more than one focus have been developed, for example, the refractive MfIOLs, diffractive MfIOLs, extended depth of field (EDOF) IOLs, and accommodating IOLs (AIOLs) were introduced to meet this need. In addition, the add-on MfIOLs have been explored as promising supplementary IOLs for pseudophakic presbyopia. When selecting the MfIOLs, the IOLs' features, patients' characteristics, preoperative eye conditions, and treatment expectations should be considered. Conclusions In this review, we focus on the multifocal IOLs (MfIOLs) commonly used for presbyopia correction and systematically summarized their optical designs and clinical outcomes. More evidence-based studies are required to provide guidelines for MfIOL selection, provide maximum visual benefits, and develop personalized visual solutions in the future.
Collapse
Affiliation(s)
- Yanan Zhu
- Corresponding author. Eye Center, Second Affiliated Hospital, School of Medicine, Zhejiang University, No. 88 Jiefang Road, Hangzhou, 310009, Zhejiang Province, China.
| | | | - Yanyan Fu
- Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310009, Zhejiang Province, China
| |
Collapse
|
5
|
Bontu S, Werner L, Kennedy S, Kamae K, Jiang B, Ellis N, Brady DG, Mamalis N. Long-term uveal and capsular biocompatibility of a new fluid-filled, modular accommodating intraocular lens. J Cataract Refract Surg 2021; 47:111-117. [PMID: 32815864 DOI: 10.1097/j.jcrs.0000000000000391] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Accepted: 07/27/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate long-term uveal and capsular biocompatibility of a new fluid-filled modular accommodating intraocular lens (IOL) consisting of base and fluid lenses. SETTING John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA. DESIGN Experimental study. METHODS Bilateral phacoemulsification was performed on 8 rabbits; 1 eye received the test IOL (Juvene) and the other a hydrophobic acrylic control IOL (SA60AT). Slitlamp examinations were performed at postoperative weeks 1 and 4, and at months 2, 3, and 6. The rabbits were killed humanely at 6 months. After gross examination from the Miyake-Apple view, IOLs were removed for implant cytology. All globes were then processed for histopathologic examination. RESULTS Uveal biocompatibility was similar between test and control IOLs up to 6 months postoperatively. Anterior capsule opacification appeared absent in the test group, and posterior capsule opacification (PCO) was significantly less in comparison with the control group throughout the study. At 6 months, central PCO was scored as 0.12 ± 0.23 with test IOLs and as 4.0 ± 0 with control IOLs (P < .0001, 2-tailed t test: paired 2-sample for means). Histopathologic examination confirmed the relative lack of capsular opacification in test eyes in comparison to controls and the absence of toxicity in any eye. CONCLUSIONS Six weeks in the rabbit model corresponds to approximately 2 years in the human eye for PCO. In this model, the Juvene IOL maintained an open and expanded capsular bag, preventing overall capsular bag opacification while retaining excellent uveal and capsular biocompatibility.
Collapse
Affiliation(s)
- Sneha Bontu
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah (Bontu, Werner, Kennedy, Kamae, Jiang, Ellis, Mamalis), Salt Lake City, Utah, and LensGen (Brady), Irvine, California, USA
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Explantation/exchange of the components of a new fluid-filled, modular, accommodating IOL. J Cataract Refract Surg 2021; 47:238-244. [PMID: 32818354 DOI: 10.1097/j.jcrs.0000000000000367] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Accepted: 07/22/2020] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate the ease of replacement and capsular stability of a new fluid-filled, modular, accommodating intraocular lens (IOL) system composed of a monofocal base lens with a fluid lens clipped inside of it. SETTING John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. DESIGN Experimental study. METHODS Five New Zealand rabbits underwent bilateral phacoemulsification with implantation of the test lens (Juvene, LensGen, Inc.) in both eyes (4 rabbits), or a control IOL in 1 eye (AcrySof, Alcon Laboratories, Inc.) and the test IOL in the other (1 rabbit). At 2 weeks, the 4 rabbits with bilateral Juvene IOLs had the clipped-in fluid lens exchanged for a new fluid lens in 1 eye, and the base and fluid lenses exchanged for a control lens in the contralateral eye. Slitlamp examinations were performed weekly for 4 weeks. The globes were enucleated and evaluated with ultrasound biomicroscopy, grossly from the posterior Miyake-Apple view, and histopathologically. RESULTS Explantation/exchange of the fluid lens was considered straightforward by the surgeon. Explantation of the base lens (4) was also safely performed, albeit more demanding, without any signs of damage to the capsular bag under clinical, ultrasound biomicroscopy, and pathological examination in the exchanged eyes. Less capsular bag opacification was observed with the Juvene lens system. CONCLUSIONS Explantation/exchange of the fluid lens component, or both fluid and base lenses, of this new lens system can be safely accomplished if necessary, because of its modular design and the relative lack of postoperative capsular bag opacification associated with it.
Collapse
|
7
|
Werner L. Intraocular Lenses: Overview of Designs, Materials, and Pathophysiologic Features. Ophthalmology 2020; 128:e74-e93. [PMID: 32619547 DOI: 10.1016/j.ophtha.2020.06.055] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Revised: 06/17/2020] [Accepted: 06/24/2020] [Indexed: 11/29/2022] Open
Abstract
This article provides an overview of intraocular lenses (IOLs) currently used in cataract surgery. Aspects presented include design features related to IOL construction and sites of fixation; optic, filter, and haptic materials; as well as pathophysiologic features of uveal biocompatibility, capsular biocompatibility, and postoperative IOL opacification. This overview also includes supplementary (add-on; piggyback) lenses implanted in eyes that are already pseudophakic and considerations on IOLs used in the pediatric population. Different IOLs are made available to surgeons each year, including lenses with increasingly complex design characteristics owing to advancements in manufacturing and surgical techniques.
Collapse
Affiliation(s)
- Liliana Werner
- Intermountain Ocular Research Center, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah.
| |
Collapse
|
8
|
Ophthalmologic Applications. Biomater Sci 2020. [DOI: 10.1016/b978-0-12-816137-1.00072-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
9
|
|
10
|
Liang YL, Jia SB. Clinical application of accommodating intraocular lens. Int J Ophthalmol 2018; 11:1028-1037. [PMID: 29977819 DOI: 10.18240/ijo.2018.06.22] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2017] [Accepted: 12/18/2017] [Indexed: 12/28/2022] Open
Abstract
The present review describes recent advances in application of accommodating intraocular lenses (AIOLs). Standard monofocal intraocular lenses (MIOLs) only correct distance vision, while AIOLs are designed to allow both good distance vision and near vision, which is achieved through the contraction and relaxation of ciliary muscles by providing transformation of the axial movement or curvature of the lens. Thus, AIOLs may be a better choice for those patients who demand a higher level of visual performance. Since techniques to analyze the performance of AIOLs have not been standardized, and there is a variety of both subjective and objective methods, it is hard to measure the performance of these intraocular lenses. By evaluating advantages and disadvantages of various AIOLs, and introducing techniques for measurement the performance postoperative, this paper can provide some relative information on choosing the type of AIOLs in the clinic.
Collapse
Affiliation(s)
- You-Ling Liang
- Department of Ophthalmology, the Second Xiangya Hospital, Central South University, Changsha 410011, Hunan Province, China
| | - Song-Bai Jia
- Department of Ophthalmology, the Second Xiangya Hospital, Central South University, Changsha 410011, Hunan Province, China
| |
Collapse
|
11
|
Aliancy J, Werner L, Ludlow J, Nguyen J, Masino B, Ha L, Mamalis N. Long-term capsule clarity with a disk-shaped intraocular lens. J Cataract Refract Surg 2018; 44:504-509. [DOI: 10.1016/j.jcrs.2017.12.029] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 12/13/2017] [Accepted: 12/22/2017] [Indexed: 10/17/2022]
|
12
|
Balgos MJTD, Vargas V, Alió JL. Correction of presbyopia: An integrated update for the practical surgeon. Taiwan J Ophthalmol 2018; 8:121-140. [PMID: 30294526 PMCID: PMC6169332 DOI: 10.4103/tjo.tjo_53_18] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Presbyopia results from loss or insufficiency of the eye's accommodative ability, and clinically manifests as the inability to focus near objects on the retina. It is one of the most common causes of visual impairment worldwide especially in adults of productive or working age. Various means of compensating for the loss of accommodative ability have been devised from optical tools such as spectacles and contact lenses, to topical medications and to surgical procedures. A comprehensive search on journal articles about topical and surgical correction of presbyopia was undertaken. The various techniques for presbyopia correction, as enumerated in these articles, are discussed in this paper with the addition of our personal experience and perspective on the future of these techniques.
Collapse
Affiliation(s)
| | | | - Jorge L Alió
- VISSUM Alicante, Spain.,Division of Ophthalmology, Universidad Miguel Hernández, Spain
| |
Collapse
|
13
|
Abstract
Objective: This paper aimed to review the current literature on the surface modification of intraocular lenses (IOLs). Data Sources: All articles about surface modification of IOLs published up to 2015 were identified through a literature search on both PubMed and ScienceDirect. Study Selection: The articles on the surface modification of IOLs were included, but those on design modification and surface coating were excluded. Results: Technology of surface modification included plasma, ion beam, layer-by-layer self-assembly, ultraviolet radiation, and ozone. The main molecules introduced into IOLs surface were poly (ethylene glycol), polyhedral oligomeric silsesquioxane, 2-methacryloyloxyethyl phosphorylcholine, TiO2, heparin, F-heparin, titanium, titanium nitride, vinyl pyrrolidone, and inhibitors of cytokines. The surface modification either resulted in a more hydrophobic lens, a more hydrophilic lens, or a lens with a hydrophilic anterior and hydrophobic posterior surface. Advances in research regarding surface modification of IOLs had led to a better biocompatibility in both in vitro and animal experiments. Conclusion: The surface modification is an efficient, convenient, economic and promising method to improve the biocompatibility of IOLs.
Collapse
Affiliation(s)
| | | | | | - Gui-Qin Wang
- Department of Ophthalmology, Navy General Hospital of PLA, Beijing 100048; Department of Ophthalmilogy, Third Clinical Medical College of Southern Medical University, Guangzhou, Guangdong 510515, China
| |
Collapse
|
14
|
|
15
|
Kramer GD, Werner L, Mamalis N. Prevention of postoperative capsular bag opacification using intraocular lenses and endocapsular devices maintaining an open or expanded capsular bag. J Cataract Refract Surg 2016; 42:469-84. [PMID: 27063529 DOI: 10.1016/j.jcrs.2016.02.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Revised: 09/02/2015] [Accepted: 09/04/2015] [Indexed: 11/19/2022]
Abstract
UNLABELLED Postoperative capsule opacification is a multifactorial physiological consequence of cataract surgery that remains the most common complication of this procedure. A literature review that included several intraocular lenses (IOLs) and endocapsular devices studied in our laboratory found that devices maintaining the capsular bag in an open or expanded state were associated with improved bag clarity. This observed effect likely occurs secondary to the complex interactions of myriad mechanisms, which include formation of a barrier to lens epithelial cell (LEC) migration, mechanical compression of residual LECs, mechanical stretch at the level of the capsule equator, maintenance of overall bag contour, and enhanced endocapsular circulation of aqueous humor. We review the designs of endocapsular devices and IOLs that minimize the degree of postoperative capsule opacification by preventing capsular bag collapse and discuss the underlying mechanisms that contribute to this phenomenon. FINANCIAL DISCLOSURE None of the authors has a financial or proprietary interest in any material or method mentioned.
Collapse
Affiliation(s)
- Gregory D Kramer
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Liliana Werner
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.
| | - Nick Mamalis
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
16
|
Evaluation of stability and capsular bag opacification with a foldable intraocular lens coupled with a protective membrane in the rabbit model. J Cataract Refract Surg 2015; 41:1738-44. [DOI: 10.1016/j.jcrs.2015.03.017] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2015] [Revised: 03/13/2015] [Accepted: 03/18/2015] [Indexed: 11/22/2022]
|