1
|
Khoramnia R, Naujokaitis T, Łabuz G, Auffarth GU. [Complex optical systems for individualized correction of presbyopia]. DIE OPHTHALMOLOGIE 2024; 121:706-713. [PMID: 39017699 DOI: 10.1007/s00347-024-02076-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Revised: 06/13/2024] [Accepted: 06/13/2024] [Indexed: 07/18/2024]
Abstract
A multitude of available intraocular lens (IOL) models enable a personalized approach to presbyopia correction in order to meet each patient's needs. This review article discusses more complex approaches which can be useful in selected cases. The concept of reversible trifocality enables correction of presbyopia using a supplementary intraocular lens (IOL), which can be removed if necessary (e.g., intolerance to multifocal optics). The use of capsulotomy-fixated IOLs enables high precision for positioning of the lens and better stability compared to conventional capsular bag-fixated IOLs, which can be particularly advantageous in multifocal optics. The mix and match concept enables a combination of different IOLs with various optical principles to achieve the desired binocular effect. Binocular IOL systems, which consist of two complementary IOLs, can be seen as a further development of the mix and match concept. Knowledge of the available options and their application can further improve correction of presbyopia.
Collapse
Affiliation(s)
- Ramin Khoramnia
- Universitäts-Augenklinik Heidelberg, INF 400, 69120, Heidelberg, Deutschland.
| | - Tadas Naujokaitis
- Universitäts-Augenklinik Heidelberg, INF 400, 69120, Heidelberg, Deutschland
| | - Grzegorz Łabuz
- Universitäts-Augenklinik Heidelberg, INF 400, 69120, Heidelberg, Deutschland
| | - Gerd U Auffarth
- Universitäts-Augenklinik Heidelberg, INF 400, 69120, Heidelberg, Deutschland
| |
Collapse
|
2
|
Lee Y, Choi HI, Bae S, Chung HS, Kim JY, Lee H. Analysis of intraocular lens decentration and tilt after femtosecond laser-assisted cataract surgery using swept-source anterior optical coherence tomography. Heliyon 2024; 10:e29780. [PMID: 38699005 PMCID: PMC11064088 DOI: 10.1016/j.heliyon.2024.e29780] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Revised: 03/21/2024] [Accepted: 04/15/2024] [Indexed: 05/05/2024] Open
Abstract
Objective To evaluate and compare the magnitude of intraocular lens (IOL) decentration and tilt following conventional and femtosecond laser-assisted cataract surgery (FLACS) using swept-source anterior optical coherence tomography (SS-OCT). Methods In this retrospective observational study, we enrolled patients who underwent conventional cataract surgery or FLACS with the implantation of hydrophobic 1-piece monofocal IOL. The magnitude of IOL decentration and tilt were measured using SS-OCT. Visual acuity, intraocular pressure, spherical equivalent, axial length, contrast sensitivity, and satisfaction questionnaire were evaluated before and one-month post-surgery. Additionally, postoperative internal cylinder measurements were obtained using a wavefront aberrometer. Correlation factors between each parameter and IOL decentration or tilt were analyzed. Results This study included 100 eyes from 100 patients. Mean IOL decentration and tilt were 0.21 ± 0.13 mm and 5.01 ± 1.49°, respectively. Conventional cataract surgery (versus FLACS, P = 0.001) and male sex (versus female, P = 0.047) were significantly correlated with higher postoperative decentration. Preoperative lens diameter (P < 0.001), preoperative lens tilt (P = 0.007), and preoperative intraocular pressure (P = 0.027) were correlated with higher postoperative tilt. Fifty eyes that underwent FLACS demonstrated mean postoperative decentration of 0.21 ± 0.13 mm and tilt of 4.64 ± 1.48°. Compared with the conventional surgery group, the FLACS group significantly differed in postoperative decentration (0.30 ± 0.12 mm, P < 0.001) but not in tilt (5.03 ± 1.35°, P = 0.173). Postoperative visual acuity did not significantly differ between the two groups. Conclusion Patients who underwent FLACS demonstrated better IOL decentration and tilt than those who underwent conventional cataract surgery one-month post-surgery. However, differences in IOL decentration and tilt did not affect postoperative visual acuity.
Collapse
Affiliation(s)
- Yunhan Lee
- Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
| | - Hoon Il Choi
- Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
| | - Seonha Bae
- Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
| | - Ho Seok Chung
- Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
| | - Jae Yong Kim
- Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
| | - Hun Lee
- Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
- Department of Ophthalmology, Brain Korea 21 Project, University of Ulsan College of Medicine, Seoul, South Korea
- Center for Cell Therapy, Asan Medical Center, Seoul, South Korea
| |
Collapse
|
3
|
Nagata M, Hanemoto T, Matsushima H, Senoo T. Relationship between anterior capsule opening and direction of intraocular lens decentration. J Cataract Refract Surg 2023; 49:917-920. [PMID: 37306397 DOI: 10.1097/j.jcrs.0000000000001235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Accepted: 06/01/2023] [Indexed: 06/13/2023]
Abstract
PURPOSE To compare intraocular lens (IOL) decentration between patients in whom the continuous curvilinear capsulorhexis (CCC) completely covers the IOL optic and those in whom it incompletely covers the IOL optic and determine how an incompletely covered CCC affects the IOL position. SETTING Tertiary hospital in Japan. DESIGN Single-center retrospective study. METHODS 57 eyes of 57 patients (mean age 70.8 ± 6.2 years) that underwent phacoemulsification and IOL (SN60WF) implantation in the bag between April 2010 and April 2015 were included in this study. The patients were classified based on whether the CCC completely (CC group) or incompletely (NCC group) covered the IOL optic using an anterior eye segment analysis system (EAS-1000). The IOL decentration of the groups was analyzed using EAS-1000 at 1 week, 1 month, 3 months, and 6 months postoperatively and compared. The relationship between the NCC location and the IOL direction at 3 months postoperatively was analyzed. RESULTS The NCC group (25 eyes) had a significantly higher amount of IOL decentration than the CC group (32 eyes) at 1 week, 1 month, 3 months, and 6 months postoperatively ( P < .05). There was a correlation between the direction of IOL decentration and the NCC location, and IOL decentration in the NCC group occurred in the opposite direction to the NCC area. CONCLUSIONS An anterior capsule opening that completely covers the IOL optic is important to control IOL decentration.
Collapse
Affiliation(s)
- Mayumi Nagata
- From the Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan (Nagata, Hanemoto, Matsushima, Senoo); Hanemoto Eye Clinic, Ibaraki, Japan (Hanemoto)
| | | | | | | |
Collapse
|
4
|
Diao C, Lan Q, Liao J, Lu P, Zhou Z, Li L, Zeng S, Yao G, Huang W, Chen Q, Lv J, Tang F, Li M, Xu F. Influence of decentration of plate-haptic toric intraocular lens on postoperative visual quality. BMC Ophthalmol 2023; 23:332. [PMID: 37474888 PMCID: PMC10360333 DOI: 10.1186/s12886-023-03061-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2023] [Accepted: 06/25/2023] [Indexed: 07/22/2023] Open
Abstract
BACKGROUND To evaluate the influence of decentration of plate-haptic toric intraocular lens (IOLs) on visual quality. METHODS This study enrolled 78 eyes of 78 patients. Patients in group A were implanted with toric IOLs, and patients in group B were implanted with monofocal IOLs. All patients were divided into group A1 and B1 (decentration below 0.3 mm) and group A2 and B2 (decentration above 0.3 mm). The uncorrected distance visual acuity (UDVA), best corrected visual acuity (BCVA), modulation transfer function cutoff (MTF cutoff), objective scatter index (OSI), strehl ratio (SR), optical interference and patients' satisfaction were measured in different pupils at three months postoperatively. The associations between decentration and visual quality were analyzed by Spearman correlation. RESULTS There were no significant differences in UDVA, BCVA, MTF cutoff, OSI, SR, optical interference and patients' satisfaction among subgroups. The differences in decentration between groups A and B were not statistically significant. In group A2, the total higher order aberrations (tHOAs) at pupil sizes of 3 mm (P = 0.046), 5 mm (P = 0.014), spherical aberrations at pupil sizes of 3 mm (P = 0.011), 4 mm (P = 0.014), 5 mm (P = 0.000), secondary astigmatism at pupil sizes of 3 mm (P = 0.002), 4 mm (P = 0.005) were higher than in group B2. Compared to group A1, group A2 had higher spherical aberrations at pupil sizes of 4 mm (P = 0.042), 5 mm (P = 0.001), 6 mm (P = 0.038), secondary astigmatism at pupil sizes of 3 mm (P = 0.013), 4 mm (P = 0.005), 6 mm (P = 0.013). Group B2 has higher coma and secondary astigmatism than group B1 at 6-mm pupil (P = 0.014, P = 0.045). Significant positive correlations were found between spherical aberrations and the decentration of group A1 and A2 at 6-mm pupils. CONCLUSION The decentration above 0.3 mm negatively affected visual quality due to increased tHOAs, spherical aberrations, coma and secondary astigmatism aberrations, the influence become larger with increasing pupil diameter. And toric IOLs are more affected by decentration than monofocal IOLs.
Collapse
Affiliation(s)
- Chunli Diao
- Department of Ophthalmology, Key Laboratory of Eye Health & Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology &Institute of Ophthalmic Diseases, the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, Guangxi, China
| | - Qianqian Lan
- Department of Ophthalmology, Key Laboratory of Eye Health & Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology &Institute of Ophthalmic Diseases, the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, Guangxi, China
| | - Jing Liao
- Department of Ophthalmology, Key Laboratory of Eye Health & Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology &Institute of Ophthalmic Diseases, the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, Guangxi, China
| | - Peng Lu
- Department of Ophthalmology, Key Laboratory of Eye Health & Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology &Institute of Ophthalmic Diseases, the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, Guangxi, China
| | - Zhou Zhou
- Department of Ophthalmology, Key Laboratory of Eye Health & Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology &Institute of Ophthalmic Diseases, the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, Guangxi, China
| | - Lanjian Li
- Department of Ophthalmology, Key Laboratory of Eye Health & Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology &Institute of Ophthalmic Diseases, the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, Guangxi, China
| | - Siming Zeng
- Department of Ophthalmology, Key Laboratory of Eye Health & Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology &Institute of Ophthalmic Diseases, the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, Guangxi, China
| | - Gang Yao
- Department of Ophthalmology, Key Laboratory of Eye Health & Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology &Institute of Ophthalmic Diseases, the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, Guangxi, China
| | - Wei Huang
- Department of Ophthalmology, Key Laboratory of Eye Health & Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology &Institute of Ophthalmic Diseases, the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, Guangxi, China
| | - Qi Chen
- Department of Ophthalmology, Key Laboratory of Eye Health & Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology &Institute of Ophthalmic Diseases, the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, Guangxi, China
| | - Jian Lv
- Department of Ophthalmology, Key Laboratory of Eye Health & Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology &Institute of Ophthalmic Diseases, the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, Guangxi, China
| | - Fen Tang
- Department of Ophthalmology, Key Laboratory of Eye Health & Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology &Institute of Ophthalmic Diseases, the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, Guangxi, China
| | - Min Li
- Department of Ophthalmology, Key Laboratory of Eye Health & Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology &Institute of Ophthalmic Diseases, the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, Guangxi, China
| | - Fan Xu
- Department of Ophthalmology, Key Laboratory of Eye Health & Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology &Institute of Ophthalmic Diseases, the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, Guangxi, China.
| |
Collapse
|
5
|
Muacevic A, Adler JR, DeNaro BB, Shelby C, Coleman WT. The Role of Multifocal Intraocular Lens Implantation in Extreme Axial Myopia: A Case Report and Literature Review. Cureus 2023; 15:e33976. [PMID: 36820123 PMCID: PMC9938765 DOI: 10.7759/cureus.33976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/17/2023] [Indexed: 01/20/2023] Open
Abstract
The prevalence of high myopia is rising globally. In addition to an increased risk of retinal detachment, high myopia is associated with earlier cataract formation. Patients with myopia are also often more motivated to become spectacle-independent after a lens procedure. However, the use of multifocal intraocular lens (MfIOL) remains controversial for patients with extreme myopia, which is classified as patients with an axial length >28 mm. Here, we present the case of a 64-year-old patient with visually significant cataract and extreme axial myopia >31 mm in both eyes who desired to be spectacle-independent. A preoperative workup revealed a normal macula with peripheral lattice degeneration. On optical coherence tomography, the macula had a normal fovea contour without the presence of a staphyloma. A thorough peripheral examination was performed by a retina specialist which required no prophylactic treatment. Pentacam analysis demonstrated a low spherical aberration and minimal ectasia risk. Cataract surgery was uneventful with a 5 mm laser capsulotomy centered over the visual axis with the placement of a trifocal intraocular lens. Two months after the cataract surgery, the remaining refractive error was corrected with a laser-assisted in situ keratomileusis enhancement. The patient achieved an uncorrected distance visual acuity of 20/15- and uncorrected near visual acuity of J1+ in both eyes. Overall, this case report and review aims to highlight important preoperative, intraoperative, and postoperative techniques to improve patient outcomes with MfIOL in patients with extreme myopia.
Collapse
|
6
|
Rossi T, Ceccacci A, Testa G, Ruggiero A, Bonora N, D'Agostino I, Telani S, Ripandelli G. Influence of anterior capsulorhexis shape, centration, size, and location on intraocular lens position: finite element model. J Cataract Refract Surg 2022; 48:222-229. [PMID: 34117178 PMCID: PMC8845527 DOI: 10.1097/j.jcrs.0000000000000711] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Accepted: 06/03/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate the influence of anterior capsulorhexis shape, dimension, and eccentricity on intraocular lens (IOL) position. SETTING Laboratory investigation. DESIGN Computational model. METHODS A finite element model of the human crystalline lens capsule and zonule was created and the anterior capsule opened to simulate centered and decentered circular and elliptic rhexis. The model calculated capsular bag stress, IOL rotation, tilt, decentration, and vaulting, related to both capsular landmarks (absolute) and a reference IOL position defined as that obtained with a 5.0 mm circular and centered rhexis. RESULTS Mean von Mises stress along the IOL major z-axis was significantly higher than that along the perpendicular x-axis in all cases (P < .001), both at the equator and at the rhexis edge. Stress at the equator was always greater than that at the rhexis edge (P < .001) regardless of the rhexis shape and position. As rhexis eccentricity increased, the stress difference between the z- and x-axes increased. Absolute IOL tilt (range 10-1 to 10-7 degrees), decentration (10-3 to 10-7 mm), rotation (10-2 to 10-3 degrees), and vaulting (10-1 mm) were negligible from an optical standpoint, but all of them were significantly greater for decentered rhexis (both round and elliptic) compared with centered (P < .05). CONCLUSIONS Anterior capsulorhexis irregularity and/or eccentricity increase IOL tilt, decentration, rotation, and vaulting in a numerically significant but optically negligible way. Von Mises stress is much greater at the capsular bag equator compared with the rhexis edge and highly asymmetrically distributed in all cases. Stress asymmetry may influence postoperative biologic processes of capsular bag shrinking and further IOL tilting or decentration.
Collapse
|
7
|
Liao M, Guo D, Liao S, Zhang W, Lin D, Tang Q. Study on the enlargement index of femtosecond laser-assisted capsulorhexis in 2-6-year-old patients with congenital cataract. BMC Ophthalmol 2021; 21:441. [PMID: 34949177 PMCID: PMC8697431 DOI: 10.1186/s12886-021-02184-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Accepted: 11/21/2021] [Indexed: 11/10/2022] Open
Abstract
Background To identify the capsule enlargement index after femtosecond laser-assisted anterior capsulorhexis in 2–6-year-old children who underwent congenital cataract surgery. Methods In this prospective case series study, femtosecond laser-assisted anterior capsulorhexis was performed in patients with congenital cataract, aged 2–6 years. The actual achieved capsulorhexis diameters were measured with Digimizer version 4.2.6. Correlation coefficient (r) and multiple linear regression analysis were used to evaluate the variables that could potentially influence anterior capsulorhexis enlargement index (E). Results This prospective study enrolled 28 eyes of 22 patients with congenital cataract. The mean age of the patients at surgery was 4.67 years ±1.54 (standard deviation [SD]). “E” of the 28 cases was 1.211 ± 0.039 (SD). Correlation analysis showed that “E” correlated significantly with the anterior chamber depth (ACD) (r = − 0.469, p = 0.021) and axial length (AL) (r = 0.452, p = 0.027). The following formula was developed by using multivariable linear regression analysis: Predicted E = 1.177–0.052 × ACD + 0.009 × AL, R2 = 0.346 (F = 4.396, p = 0.046). Conclusions The anterior capsulorhexis enlargement index and its calculation formula could help to set up an accurate programmed capsulorhexis diameter for femtosecond laser-assisted congenital cataract surgery in children aged 2–6 years. Thus, an appropriate actual capsulorhexis diameter could be achieved.
Collapse
Affiliation(s)
- Menglian Liao
- AIER School of Ophthalmology, Central South University, Changsha, 410015, Hunan, China.,Changsha AIER Eye Hospital, No. 388, Furong Middle Road, Changsha, 410015, Hunan, China
| | - Da Guo
- Changsha AIER Eye Hospital, No. 388, Furong Middle Road, Changsha, 410015, Hunan, China
| | - Shan Liao
- Changsha AIER Eye Hospital, No. 388, Furong Middle Road, Changsha, 410015, Hunan, China
| | - Wenwen Zhang
- AIER School of Ophthalmology, Central South University, Changsha, 410015, Hunan, China.,Changsha AIER Eye Hospital, No. 388, Furong Middle Road, Changsha, 410015, Hunan, China
| | - Ding Lin
- AIER School of Ophthalmology, Central South University, Changsha, 410015, Hunan, China.,Changsha AIER Eye Hospital, No. 388, Furong Middle Road, Changsha, 410015, Hunan, China
| | - Qiongyan Tang
- AIER School of Ophthalmology, Central South University, Changsha, 410015, Hunan, China. .,Changsha AIER Eye Hospital, No. 388, Furong Middle Road, Changsha, 410015, Hunan, China.
| |
Collapse
|
8
|
Review and recommendations for univariate statistical analysis of spherical equivalent prediction error for IOL power calculations. J Cataract Refract Surg 2021; 47:65-77. [PMID: 32769751 DOI: 10.1097/j.jcrs.0000000000000370] [Citation(s) in RCA: 64] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Accepted: 07/22/2020] [Indexed: 11/26/2022]
Abstract
PURPOSE To provide a reference for study design comparing intraocular lens (IOL) power calculation formulas, to show that the standard deviation (SD) of the prediction error (PE) is the single most accurate measure of outcomes, and to provide the most recent statistical methods to determine P values for type 1 errors. SETTING Baylor College of Medicine, Houston, Texas, and University of Southern California, Los Angeles, California, USA. DESIGN Retrospective consecutive case series. METHODS Two datasets comprised of 5200 and 13 301 single eyes were used. The SDs of the PEs for 11 IOL power calculation formulas were calculated for each dataset. The probability density functions of signed and absolute PE were determined. RESULTS None of the probability distributions for any formula in either dataset was normal (Gaussian). All the original signed PE distributions were not normal, but symmetric and leptokurtotic (heavy tailed) and had higher peaks than a normal distribution. The absolute distributions were asymmetric and skewed to the right. The heteroscedastic method was much better at controlling the probability of a type I error than older methods. CONCLUSIONS (1) The criteria for patient and data inclusion were outlined; (2) the appropriate sample size was recommended; (3) the requirement that the formulas be optimized to bring the mean error to zero was reinforced; (4) why the SD is the single best parameter to characterize the performance of an IOL power calculation formula was demonstrated; and (5) and using the heteroscedastic statistical method was the preferred method of analysis was shown.
Collapse
|
9
|
Prospective comparison of apex-centered vs standard pupil-centered femtosecond laser-assisted capsulotomy in cataract surgery. J Cataract Refract Surg 2021; 47:606-611. [PMID: 33196566 DOI: 10.1097/j.jcrs.0000000000000496] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Accepted: 10/15/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE To compare the lens tilt after apex-centered capsulotomy with standard pupil-centered capsulotomy. SETTING Clinical practice. DESIGN Prospective, randomized, investigator-masked trial. METHODS This prospective, randomized, investigator masked study included 40 patients with age-related cataract scheduled for femtosecond laser-assisted cataract surgery (FLACS) in both eyes. The main outcome was the tilt of the intraocular lens (IOL), measured with the IOLMaster 700. RESULTS The study enrolled 80 eyes of 40 patients. The mean distance from the center of the apex-centered capsulotomy to the pupil-centered capsulotomy was 175.8 ± 97.2 μm. The amount of IOL tilt was not significantly reduced with the new technique (P > .05). Tilt orientation was more stable in eyes treated with apex-centered capsulotomy. CONCLUSIONS Centration of the capsulotomy on the lens apex in FLACS does not influence the amount of IOL tilt but the orientation stability. The clinical importance of this finding has to be further elucidated.
Collapse
|
10
|
Chen X, Gu X, Wang W, Xiao W, Jin G, Wang L, Dai Y, Zhang E, Ruan X, Liu Z, Luo L, Liu Y. Characteristics and factors associated with intraocular lens tilt and decentration after cataract surgery. J Cataract Refract Surg 2021; 46:1126-1131. [PMID: 32352251 DOI: 10.1097/j.jcrs.0000000000000219] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
PURPOSE To analyze the characteristics and factors associated with intraocular lens (IOL) tilt and decentration after uneventful phacoemulsification with IOL implantation. SETTING Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. DESIGN Cross-sectional study. METHODS All patients underwent a general ophthalmologic examination and anterior segment photography. IOL tilt and decentration were measured with a second-generation anterior segment optical coherence tomography (Casia2). Univariate and multivariate regression analyses were performed to assess the association between IOL tilt and decentration with ocular biometric and systemic parameters, and the visual acuity. RESULTS A total of 196 eyes of 196 patients were enrolled in this study. IOLs showed a mean tilt of 4.8 degrees toward the inferotemporal direction, and the mean decentration was 0.21 mm. Both eyes presented a mirror symmetry relationship. Twenty-two eyes (11.22%) had a tilt greater than 7 degrees, and 21 eyes (10.72%) had a decentration more than 0.4 mm. Multivariate regression analysis showed previous pars plana vitrectomy (PPV) and short axial length (AL) were associated with greater IOL tilt (P = .014 and P < .001). In addition, long AL, thicker lens, and less capsulorhexis-IOL overlap were positively correlated with decentration (P < .001, P = .029, and P = .026). Corrected distance visual acuity did not directly correlate with IOL tilt and decentration (P = .417 and P = .550). CONCLUSIONS PPV history and short AL were associated with greater IOL tilt, whereas longer AL, thicker lens, and overlarge capsulorhexis contribute to greater decentration. Implantation of toric and multifocal IOLs in these patients should be cautious.
Collapse
Affiliation(s)
- Xiaoyun Chen
- From the State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong, China
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Prospective study to compare axial position stability after fellow-eye implantation of 2 distinct intraocular lens designs. J Cataract Refract Surg 2021; 47:999-1005. [PMID: 33577276 DOI: 10.1097/j.jcrs.0000000000000557] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Accepted: 12/09/2020] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare the dynamics of axial intraocular lens (IOL) position and stability in the capsular bag after fellow-eye implantation of a 1-piece C-loop and a 4-point haptic IOL. SETTING Hanusch Hospital, Vienna. DESIGN Prospective, comparative, randomized bilateral study. METHODS One hundred eyes of 50 patients were randomly implanted with a C-loop IOL (CT LUCIA 611P) in 1 eye and a 4-point haptic IOL (CT ASPHINA 409MP) in the other eye. Anterior chamber depth (ACD) was measured at 1 week (W1), 1 month (M1), and 4 to 6 months (M4-6) postoperatively using a swept-source optical coherence tomography device (IOLMaster 700). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity, and subjective refraction outcomes were assessed at M4-6 postoperative follow-up. RESULTS Hundred eyes of 50 patient were included. Pseudophakia ACD values at W1, M1, and M4-6 timepoints were significantly different in eyes implanted with the C-loop IOL compared with the 4-point haptic IOL (P < .001). The overall IOL shift was 0.25 ± 0.16 mm for the 4-point haptic IOL and 0.14 ± 0.09 mm for the C-loop IOL (P < .001). The M4-6 mean monocular UDVA outcome for eyes with C-loop IOL was 0.06 ± 0.14 logarithm of the minimum angle of resolution (logMAR) and 0.03 ± 0.10 logMAR for the eyes with 4-point haptic IOL. M4-6 mean spherical equivalent was -0.32 ± 0.48 diopter (D) in the C-loop IOL group and -0.33 ± 0.42 D in the 4-point haptic IOL group. CONCLUSIONS Statistically significant differences in IOL design results in different postoperative ACD values. No relevant or statistically significant differences were found in refraction or visual acuity between the groups.
Collapse
|
12
|
Lu LW, Rocha-de-Lossada C, Rachwani-Anil R, Flikier S, Flikier D. The role of posterior corneal power in 21st century biometry: A review. J Fr Ophtalmol 2021; 44:1052-1058. [PMID: 34148699 DOI: 10.1016/j.jfo.2020.11.031] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 10/31/2020] [Accepted: 11/05/2020] [Indexed: 10/21/2022]
Abstract
PURPOSE Intraocular lens (IOL) calculation and biometry have evolved significantly in recent decades. However, present outcomes are still suboptimal. Our objective is to summarize the results reported in the literature with regard to a new variable, the value of the relationship between anterior and posterior corneal curvature in the biometric calculation of IOL power. METHODS We have created a narrative revision of the existing evidence regarding the posterior to anterior corneal curvature ratio in IOL calculation. RESULTS The corneal posterior/anterior ratio (P/A ratio), also called Gullstrand ratio, has a standard deviation of 2.4% in normal people, hence causing a possible IOL power miscalculation error of up to 0.75 diopters (D). This error is magnified in pathological corneas or in those with previous refractive surgery. Including the P/A ratio in the IOL formula reduces errors in the calculation of IOL power. CONCLUSIONS Measurement of the posterior corneal surface should be recommended prior to IOL calculation, given the demonstrated results regarding the P/A ratio for IOL power calculation. Regarding toric IOL calculation, we suggest incorporation of all internal astigmatic vectors, for instance, posterior corneal surface, IOL tilt induced toricity, and retinal astigmatism. All of these factors may improve surgical outcomes.
Collapse
Affiliation(s)
- L W Lu
- Arizona State University, Tempe, Arizona, USA; Cayetano Heredia University School of Medicine, Department of Ophthalmology, San Martín de Porres, Peru
| | - C Rocha-de-Lossada
- Department of Ophthalmology (QVision), Vithas Almería, Spain; University Hospital Virgen de las Nieves, Granada, Spain; Ceuta Medical Center, Spain
| | - R Rachwani-Anil
- Hospital Regional Universitario de Málaga, Ophthalmology Department, Málaga, Spain.
| | - S Flikier
- Instituto de Cirugía Ocular, San José, Costa Rica
| | - D Flikier
- Instituto de Cirugía Ocular, San José, Costa Rica
| |
Collapse
|
13
|
Auffarth GU, Friedmann E, Breyer D, Kaymak H, Holland D, Dick B, Petzold A, Shah S, Ladaria LS, Garcia SA, Khoramnia R. Stability and Visual Outcomes of the Capsulotomy-Fixated FEMTIS-IOL After Automated Femtosecond Laser-Assisted Anterior Capsulotomy. Am J Ophthalmol 2021; 225:27-37. [PMID: 33412122 DOI: 10.1016/j.ajo.2020.12.025] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Revised: 12/22/2020] [Accepted: 12/22/2020] [Indexed: 12/13/2022]
Abstract
PURPOSE To evaluate stability and performance of a new monofocal anterior capsulotomy-fixated intraocular lens (IOL) (FEMTIS; Teleon Surgical B.V., Spankeren, Netherlands) after femtosecond laser-assisted cataract surgery (FLACS). DESIGN Prospective, multicenter, interventional, noncomparative case series. METHODS FLACS with FEMTIS IOL was performed in 336 eyes of 183 cataract patients with fixation of the IOL to the anterior capsulotomy followed up for 12 months. Examination included uncorrected distance visual acuity (UDVA), best-corrected visual acuity (CDVA), subjective refraction, IOL centration, posterior capsule opacification (PCO), and investigators' satisfaction questionnaire. RESULTS At 12 months, mean IOL rotation was 1.50 ± 1.76 degrees and decentration 0.14 ± 0.14 mm from baseline (day of surgery). Mean horizontal IOL tilt was 0.70 ± 0.60 degrees and vertical 1.15 ± 1.06 degrees relative to the baseline (crystalline lens). Mean distance between IOL and iris was 0.32 mm to 0.36 mm for all measured meridians. Mean UDVA was 0.12 ± 0.14 logMAR (range -0.20 to 0.54 logMAR), mean CDVA -0.01 ± 0.09 logMAR (range -0.30 to 0.20 logMAR). Mean spherical equivalent was 0.35 ± 0.53 diopter (D) and 98% of eyes (n = 235) were within ±1.0 D. Median PCO score was 1 with an Nd:YAG laser rate of 3.1% after 12 months. Most surgeons were very satisfied (median score: 1) with surgery and implanted IOL. CONCLUSIONS Implantation of FEMTIS IOL provided excellent visual and stable refractive outcomes. IOL decentration was very low compared to other published studies and showed an exceptional high in-the-bag stability over a 12-month period. This lens benefits from femtosecond laser capsulotomies. It can be positioned very predictably and offers an optimal platform for toric and multifocal IOL optics.
Collapse
|
14
|
Ding X, Wang Q, Xiang L, Chang P, Huang S, Zhao YE. Three-Dimensional Assessments of Intraocular Lens Stability With High-Speed Swept-Source Optical Coherence Tomography. J Refract Surg 2021; 36:388-394. [PMID: 32521026 DOI: 10.3928/1081597x-20200420-01] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2019] [Accepted: 04/20/2020] [Indexed: 12/28/2022]
Abstract
PURPOSE To evaluate the effect of intraocular lens (IOL) optic overlapping on IOL stability and to determine the relationship between the capsulorhexis and IOL movement with the three-dimensional method of swept-source optical coherence tomography (SS-OCT). METHODS This study identified patients with age-related cataracts and divided them into two groups according to their anterior capsule and IOL optic relationship: total anterior capsule overlap (360°) and partial anterior capsule overlap (< 360°). Standard SS-OCT radial scanning was performed in all eyes at 1 day, 1 week, 1 month, and 3 months after cataract surgery, respectively. The obtained photographs were used for the postoperative position measurements of capsulorhexis and IOL after three-dimensional reconstruction. RESULTS This study included 46 eyes of 34 patients: total overlap group (n = 29) and partial overlap group (n = 17). The postoperative aqueous depth significantly decreased in the first week after surgery (P < .001). The IOL tilt was greater in the partial overlap group than that in the total overlap group (P = .014). The IOL moved significantly in the first week postoperatively (both P < .001). IOL decentration in the x-axis was greater in the partial overlap group than that in the total overlap group (P = .024). The IOL and capsulorhexis both moved sharply in the first week (both P < .05). The IOL moved consistently with the capsulorhexis in the 3 months after surgery (all P > .05). CONCLUSIONS The total overlap group showed better IOL centrality and stability. IOL movement may be driven by capsular bag contraction and fibrosis. Thus, it was demonstrated that postoperative IOL position and IOL performance were closely linked with proper size of central continuous curvilinear capsulorhexis. [J Refract Surg. 2020;36(6):388-394.].
Collapse
|
15
|
Lin HY, Kao ST, Chuang YJ, Chen S, Lin PJ. Comparison of cumulative dispersed energy between conventional phacoemulsification and femtosecond laser-assisted cataract surgery with two different lens fragmentation patterns. Lasers Med Sci 2021; 37:843-848. [PMID: 33876322 PMCID: PMC8918128 DOI: 10.1007/s10103-021-03321-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 04/11/2021] [Indexed: 10/31/2022]
Abstract
The purpose of the study is to compare the total ultrasound power used between eyes undergoing different lens fragmentation patterns of femtosecond laser-assisted cataract surgery (FLACS) and conventional phacoemulsification surgery (CPS). A total of 506 patient eyes underwent preoperative grading of lens opacity using the Lens Opacity Classification System III (LOCSIII). The eyes were divided into two subgroups: subgroup 1 had a LOCSIII grade of 1-3, and subgroup 2 had a LOCSIII grade of 4-6. The eyes underwent FLACS (LenSx) for clear corneal wound, capsulotomy, and lens fragmentation. Either a grid pattern or radial pattern was used for lens fragmentation. The eyes received one of the following three treatments: (1) CPS without femtosecond laser assistant, (2) FLACS with a grid pattern (FGP) lens fragment, or (3) FLACS with a quadrant pattern (FQP) lens fragment. The mean cumulative dispersed energy (CDE) for each subgroup and treatment was evaluated. The mean CDE was lower in the two FLACS groups (1.21±1.91 in FGP and 1.22±1.92 in FQP) than that in the CPG group (2.67±2.84). In subgroup 1, CDE was higher in the CPG group (1.54±1.18) as compared with the FLACS groups (0.16±0.31 in FGP and 0.74±1.17 in FQP; P<0.001). In subgroup 2, CDE was higher in the CPG (6.47±3.46) as compared with the FLACS groups (2.74±2.21 in FGP and 5.34±2.17 in FQP; P<0.001). CDE was lower in the two FLACS groups than that in the CPS group, and CDE was the lowest with FGP in both subgroups 1 and 2.
Collapse
Affiliation(s)
- Hung-Yuan Lin
- Universal Eye Center, Zhong-Li, Taiwan.,Department of Optometry, Central Taiwan University of Science and Technology, Taichung, Taiwan.,Department of Ophthalmology, Fujian Medical University, Fujian Sheng, China
| | | | | | | | | |
Collapse
|
16
|
Angle alpha orientation and magnitude distribution in a cataract surgery population. J Cataract Refract Surg 2021; 46:372-377. [PMID: 32050213 DOI: 10.1097/j.jcrs.0000000000000066] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To report normative angle alpha orientation and magnitude distribution in a cataract surgery patient population. SETTING U.S. academic medical center. DESIGN Retrospective review. METHODS A total of 11 871 wavefront aberrometer/corneal topographer angle alpha measurements were performed over 40 months, yielding 8773 bilateral measurements (73.9%) with zero bad wavefront datapoints. The analysis was limited to the first right-eye scan for 3382 unique patients. The angle alpha magnitudes (millimeters) and orientations (degrees) were analyzed for these unique right eyes. RESULTS For the 3,382 unique patients, the mean angle alpha magnitude was 0.44 ± 0.15 mm (median, 0.44 mm; 25th and 75th percentiles 0.34 mm, 0.53 mm). Angle alpha orientation was predominantly horizontal (P < .01), with a mean of 186 ± 32 degrees. The expected point of intraocular lens (IOL) centration (EPIC) based on the geometric center of the corneal limbus was temporal to the visual axis in 3212 eyes (95%), nasal in 92 eyes (2.7%), inferior in 56 eyes (1.7%), and superior in 22 eyes (0.6%). The mean angle alpha magnitude was 0.3 mm or less in 607 eyes (18%) and 0.5 mm or greater in 1089 eyes (32%). CONCLUSIONS Angle alpha is a predominantly horizontal phenomenon with a mean EPIC of 0.44 mm temporal to the visual axis. This information may assist in determining eligibility for patients in multifocal IOL implantation.
Collapse
|
17
|
Portney DS, Thibodeau AR, Mian SI. Recent Updates in Femtosecond Laser-assisted Cataract Surgery. Int Ophthalmol Clin 2021; 61:77-94. [PMID: 33337795 DOI: 10.1097/iio.0000000000000338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
18
|
Cornaggia A, Clerici LM, Felizietti M, Rossi T, Pandolfi A. A numerical model of capsulorhexis to assess the relevance of size and position of the rhexis on the IOL decentering and tilt. J Mech Behav Biomed Mater 2020; 114:104170. [PMID: 33144045 DOI: 10.1016/j.jmbbm.2020.104170] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Accepted: 10/23/2020] [Indexed: 10/23/2022]
Abstract
Finite element models of human crystalline capsular bag and zonular fibers are used to estimate the mechanical response of the capsule to the presence of a C-loop Intra-Ocular Lens (IOL) after cataract surgery, to assess the influence of capsulorhexis size, shape and location on IOL decentration and tilt. The model includes, in the anterior capsule, a hole with variable size, shape and position, which represents the rhexis obtained in a manual or laser-assisted manner. The IOL is not explicitly modelled, but its action is reproduced by means of a set of elastic ties, connecting the opposite sides of the bag and exerting the force corresponding to an expanded IOL. Numerical simulations show that IOL decentration and tilt are not related to the size of the rhexis. A decentered rhexis induces IOL decentration <40 μm and a tilt <12°; the combination of non-circular shape and decentering of the rhexis induces IOL decentration <47 μm. While the introduction of a circular central rhexis causes an increment of the stresses in the capsule up to 100% relative to the physiological state, the combination of rhexis decentering and non-circular shape causes an additional 10% stress change. The values of IOL decentering and IOL tilt obtained from simulations are of scarce relevance in the clinical practice.
Collapse
Affiliation(s)
- Aram Cornaggia
- Politecnico di Milano, Civil and Environmental Engineering Department, Italy
| | - Laura M Clerici
- Politecnico di Milano, Chemistry, Materials, and Chemical Engineering Department, Italy
| | - Marta Felizietti
- Politecnico di Milano, Chemistry, Materials, and Chemical Engineering Department, Italy
| | | | - Anna Pandolfi
- Politecnico di Milano, Civil and Environmental Engineering Department, Italy.
| |
Collapse
|
19
|
Fernández-Vega Cueto A, Rodríguez-Una I, Rodríguez-Calvo PP, Alfonso JF. Femtosecond laser-assisted cataract surgery in shallow anterior chamber cases. Int Ophthalmol 2020; 41:707-717. [PMID: 33099746 DOI: 10.1007/s10792-020-01628-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Accepted: 10/17/2020] [Indexed: 11/29/2022]
Abstract
PURPOSE To assess the effectiveness, safety and predictability of femtosecond laser-assisted cataract surgery (FLACS) in eyes with shallow anterior chamber (AC). METHODS This is a prospective consecutive clinical study. All eyes presented an anterior chamber depth (ACD) ≤ 2.1 mm and were submitted to FLACS with monofocal intraocular lens (mIOL) or trifocal intraocular lens (tIOL) implantation. Uncorrected distance visual acuity (VA) and corrected distance VA values were used to assess efficacy and safety of the surgery. Refraction, intraocular pressure (IOP), endothelial cell density (ECD) and ACD were evaluated before and 6 months post-surgery. RESULTS Phacoemulsification was carried out successfully in all eyes, without intra- or postoperative complications. Efficacy and safety indexes were 0.96 and 1.26 for the mIOL group, and 0.87 and 1.01 for the tIOL group, respectively. The mean postoperative spherical equivalent was - 0.06 ± 0.28D and - 0.14 ± 0.38D for the mIOL and tIOL groups, respectively. The ECD varied from 2470 ± 483 to 2009 ± 538 cells/mm2 (p < 0.05) and from 2443 ± 319 to 2245 ± 628 cells/mm2 (p = 0.06) for the mIOL and tIOL groups, respectively. IOP significantly decreased (p < 0.05) after the surgery from 14.34 to 12.85 mmHg for the mIOL group and from 14.37 to 11.91 mmHg for the tIOL group, with a general reduction of medical hypotensive treatment in both groups (85% of cases required ≤ number of medications). ACD changed significantly (p < 0.05) from 1.96 ± 0.15 mm to 3.75 ± 0.30 mm after the surgery in the mIOL group and from 1.94 ± 0.15 mm to 3.23 ± 0.21 mm for the tIOL group. CONCLUSION FLACS with implantation of either mIOL or tIOL may provide good efficacy, safety and predictability in eyes with shallow AC.
Collapse
Affiliation(s)
- Andrés Fernández-Vega Cueto
- Fernández-Vega Ophthalmological Institute, University of Oviedo, Avda. Dres. Fernández-Vega, 34, 33012, Oviedo, Spain
| | - Ignacio Rodríguez-Una
- Fernández-Vega Ophthalmological Institute, University of Oviedo, Avda. Dres. Fernández-Vega, 34, 33012, Oviedo, Spain.
| | - Pedro P Rodríguez-Calvo
- Fernández-Vega Ophthalmological Institute, University of Oviedo, Avda. Dres. Fernández-Vega, 34, 33012, Oviedo, Spain
| | - José F Alfonso
- Fernández-Vega Ophthalmological Institute, University of Oviedo, Avda. Dres. Fernández-Vega, 34, 33012, Oviedo, Spain
| |
Collapse
|
20
|
Ashena Z, Maqsood S, Ahmed SN, Nanavaty MA. Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations. Vision (Basel) 2020; 4:vision4030041. [PMID: 32937750 PMCID: PMC7559075 DOI: 10.3390/vision4030041] [Citation(s) in RCA: 50] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Revised: 08/17/2020] [Accepted: 09/11/2020] [Indexed: 02/07/2023] Open
Abstract
Tilt and decentration of intraocular lenses (IOL) may occur secondary to a complicated cataract surgery or following an uneventful phacoemulsification. Although up to 2–3° tilt and a 0.2–0.3 mm decentration are common and clinically unnoticed for any design of IOL, larger extent of tilt and decentration has a negative impact on the optical performance and subsequently, the patients’ satisfaction. This negative impact does not affect various types of IOLs equally. In this paper we review the methods of measuring IOL tilt and decentration and focus on the effect of IOL tilt and decentration on visual function, in particular visual acuity, dysphotopsia, and wavefront aberrations. Our review found that the methods to measure the IOL displacement have significantly evolved and the available studies have employed different methods in their measurement, while comparability of these methods is questionable. There has been no universal reference point and axis to measure the IOL displacement between different studies. A remarkably high variety and brands of IOLs are used in various studies and occasionally, opposite results are noticed when two different brands of a same design were compared against another IOL design in two studies. We conclude that <5° of inferotemporal tilt is common in both crystalline lenses and IOLs with a correlation between pre- and postoperative lens tilt. IOL tilt has been noticed more frequently with scleral fixated compared with in-the-bag IOLs. IOL decentration has a greater impact than tilt on reduction of visual acuity. There was no correlation between IOL tilt and decentration and dysphotopsia. The advantages of aspheric IOLs are lost when decentration is >0.5 mm. The effect of IOL displacement on visual function is more pronounced in aberration correcting IOLs compared to spherical and standard non-aberration correcting aspherical IOLs and in multifocal versus monofocal IOLs. Internal coma has been frequently associated with IOL tilt and decentration, and this increases with pupil size. There is no correlation between spherical aberration and IOL tilt or decentration. Although IOL tilt produces significant impact on visual outcome in toric IOLs, these lenses are more sensitive to rotation compared to tilt.
Collapse
Affiliation(s)
- Zahra Ashena
- Sussex Eye Hospital, Brighton & Sussex University Hospitals NHS Trust, Eastern Road, Brighton BN2 5BF, UK;
| | - Sundas Maqsood
- Eastbourne District General Hospital, Kings Drive, Eastbourne BN21 2UD, UK;
| | - Syed Naqib Ahmed
- Northampton General Hospital, Cliftonville, Northampton NN1 5BD, UK;
| | - Mayank A. Nanavaty
- Sussex Eye Hospital, Brighton & Sussex University Hospitals NHS Trust, Eastern Road, Brighton BN2 5BF, UK;
- Brighton & Sussex Medical School, University of Sussex, Falmer, Brighton BN1 9PX, UK
- Correspondence: ; Tel.: +44-01273-606126
| |
Collapse
|
21
|
Kulikov AN, Danilenko EV, Dzilikhov AA. [Algorithm for predicting axial displacement of the optic part of IOL after phacoemulsification]. Vestn Oftalmol 2020; 136:38-43. [PMID: 32366068 DOI: 10.17116/oftalma202013602138] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To test a prediction algorithm for deflection of the optical part of IOL after uncomplicated phacoemulsification. MATERIAL AND METHODS The study included 226 patients (287 eyes) who underwent phacoemulsification with implantation of intracapsular AcrySof IOL. Preoperative examination included IOLMaster, Lenstar LS 900 biometry and Pentacam HR keratotopography. All measurement were repeated one month postoperatively. To determine the tilt and deflection of the IOL's optical part, anterior segment optical coherence tomography (OCT) was performed on Topcon 3DOCT-2000. RESULTS OCT data analysis helps identify the slope and deflection of the IOL's optical part relative to the pupil plane. In the previous study we built logistic regression models for predicting the deflection of the IOL's optical part with high predictive quality based on the calculated IOL power and preoperative biometry measurements. When checked with new patient data, the areas under the ROC curves have changed slightly. Large area under the ROC curves with small deviation rates, as well as retention of the level of true positive responses with little increase in false negative responses verify the high quality of the models. CONCLUSION Logistic regression models based on the optical power of the implanted IOL, as well as on a combination of preoperative biometry data from IOLMaster and Lenstar LS 900, make it possible to predict the probability of deflection of the optical part of IOL with high reliability and promptly correct the IOL power.
Collapse
Affiliation(s)
- A N Kulikov
- S.M. Kirov Military Medical Academy, St. Petersburg, Russia
| | - E V Danilenko
- S.M. Kirov Military Medical Academy, St. Petersburg, Russia
| | - A A Dzilikhov
- S.M. Kirov Military Medical Academy, St. Petersburg, Russia
| |
Collapse
|
22
|
Abstract
PURPOSE Review scientific literature concerning femtosecond laser-assisted cataract surgery. METHODS Following databases were searched: CENTRAL (Cochrane Eyes and Vision Trials Register; Cochrane Library: Issue 2 of 12, June 2019), Ovid MEDLINE® without Revisions (1996 to June 2019), Ovid MEDLINE® (1946 to June 2019), Ovid MEDLINE® Daily Update June 2019, MEDLINE and MEDLINE Non-Indexed Items, Embase (1980-2019), Embase (1974 to June 2019), Ovid MEDLINE® and Epub Ahead of Print, in-Process & Other Non-Indexed Citations and Daily (1946 to June 2019), Web of Science (all years), the metaRegister of Controlled Trials ( www.controlled-trials.com ), ClinicalTrials.gov ( www.clinicaltrial.gov ) and World Health Organization International Clinical Trials Registry Platform ( www.who.int/ictrp/search/en ). Search terms/keywords included 'Femtosecond laser' combined with 'cataract', 'cataract surgery'. RESULTS Based on quality of their methodology and their originality, 121 articles were reviewed, including randomised controlled trials, cohort studies, case-controlled studies, case series, case reports and laboratory studies. Each step of the femtosecond laser-assisted cataract surgery procedure (corneal incisions, arcuate keratotomies, capsulotomy and lens fragmentation) has been discussed with relevance to published outcomes, as well as complication rates of femtosecond laser-assisted cataract surgery, and what we can learn from the larger studies/meta-analyses and the economics of femtosecond laser-assisted cataract surgery within different healthcare settings. CONCLUSION Studies suggest that the current clinical outcomes of femtosecond laser-assisted cataract surgery are not different to conventional phacoemulsification surgery and it is not cost effective when compared with conventional phacoemulsification surgery. In its current technological form, it is a useful surgical tool in specific complex cataract scenarios, but its usage has not been shown to translate into better clinical outcomes.
Collapse
Affiliation(s)
- Harry W Roberts
- King's College London, London, UK.,Norfolk and Norwich University Hospital NHS Foundation Trust, Norwich, UK
| | | | - David Ps O'Brart
- King's College London, London, UK.,Department of Ophthalmology, Guy's and St Thomas' NHS Foundation Trust, London, UK
| |
Collapse
|
23
|
Meng J, He W, Rong X, Miao A, Lu Y, Zhu X. Decentration and tilt of plate-haptic multifocal intraocular lenses in myopic eyes. EYE AND VISION 2020; 7:17. [PMID: 32280721 PMCID: PMC7137526 DOI: 10.1186/s40662-020-00186-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/28/2019] [Accepted: 03/17/2020] [Indexed: 12/18/2022]
Abstract
Background To investigate the decentration and tilt of plate-haptic multifocal intraocular lenses (MfIOLs) in myopic eyes. Methods Myopic (axial length [AXL] > 24.5 mm) and non-myopic (21.0 mm < AXL ≤ 24.5 mm) cataract eyes were enrolled in this prospective study and randomly assigned to receive implantation of Zeiss AT LISA tri 839MP lenses (Group A) or Tecnis ZMB00 lenses (Group B). In total, 122 eyes of 122 patients were available for analysis. Decentration and tilt of MfIOLs, high-order aberrations (HOAs), and modulation transfer functions (MTFs) were evaluated using the OPD-Scan III aberrometer 3 months postoperatively. Subjective symptoms were assessed with a Quality of Vision questionnaire. Results Near and distance visual acuities, tilt and horizontal decentration did not differ between the two groups, postoperatively. However, myopic eyes of Group B showed greater vertical decentration than those of Group A (− 0.17 ± 0.14 mm vs. -0.03 ± 0.09 mm, respectively), particularly when the MfIOLs were placed horizontally or obliquely. Overall decentration of myopic eyes was greater in Group B than in Group A (0.41 ± 0.15 mm vs. 0.16 ± 0.10 mm, respectively). In Group B, AXL was negatively correlated with vertical decentration and positively correlated with overall decentration. No such correlations were found in Group A. Intraocular total HOAs, coma, trefoil and spherical aberrations were lower in Group A than in Group B for a 6.0 mm pupil among myopic eyes. Generally, Group A had better MTFs and fewer subjective symptoms than Group B among myopic eyes. Conclusions Plate-haptic design of MfIOLs may be a suggested option for myopic cataract eyes due to the less inferior decentration and better visual quality postoperatively.
Collapse
Affiliation(s)
- Jiaqi Meng
- 1Eye Institute, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031 China
| | - Wenwen He
- 1Eye Institute, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031 China.,2Key Laboratory of Myopia, Ministry of Health, Shanghai, China.,Key Laboratory of Visual Impairment and Restoration, Shanghai, China.,4Key NHC key Laboratory of Myopia (Fudan University), Shanghai, China.,Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| | - Xianfang Rong
- 1Eye Institute, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031 China
| | - Ao Miao
- 1Eye Institute, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031 China
| | - Yi Lu
- 1Eye Institute, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031 China.,2Key Laboratory of Myopia, Ministry of Health, Shanghai, China.,Key Laboratory of Visual Impairment and Restoration, Shanghai, China.,4Key NHC key Laboratory of Myopia (Fudan University), Shanghai, China.,Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| | - Xiangjia Zhu
- 1Eye Institute, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031 China.,2Key Laboratory of Myopia, Ministry of Health, Shanghai, China.,Key Laboratory of Visual Impairment and Restoration, Shanghai, China.,4Key NHC key Laboratory of Myopia (Fudan University), Shanghai, China.,Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| |
Collapse
|
24
|
Iwama Y, Maeda N, Ikeda T, Nakashima H, Emi K. Impact of vitrectomy and air tamponade on aspheric intraocular lens tilt and decentration and ocular higher-order aberrations: phacovitrectomy versus cataract surgery. Jpn J Ophthalmol 2020; 64:359-366. [PMID: 32200517 DOI: 10.1007/s10384-020-00737-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Accepted: 02/12/2020] [Indexed: 01/19/2023]
Abstract
PURPOSE To evaluate the impact of vitrectomy and air tamponade on aspheric intraocular lens (IOL) tilt and decentration and postoperative internal higher-order aberrations (HOAs) in combined cataract surgery and vitrectomy (phacovitrectomy). STUDY DESIGN Prospective comparative observational study. METHODS Forty-five eyes that underwent phacovitrectomy using aspheric IOLs and 18 eyes that only underwent cataract surgery also using aspheric IOLs were prospectively evaluated. The subjects were divided into three groups: phacovitrectomy without fluid-air exchange (F/Ax) or with F/Ax and cataract surgery alone (Groups A, B, and C, respectively) Surgery-induced changes in lens tilt and decentration and internal HOAs were compared between each pair of groups. Subgroup analysis was conducted for cases with largely tilted (> 7°) or decentered (> 0.40 mm) IOLs 1 month postoperatively. RESULTS Surgery-induced changes in lens tilt in Group B were significantly more pronounced than those in Group C at 1 week, 1 month, and 3 months postoperatively (P = 0.007, 0.009, and 0.043, respectively), while there was no significant difference in surgery-induced changes in lens decentration among the groups. IOLs in Group B were tilted and decentered toward the inferonasal direction. In contrast, there was no significant difference in internal HOAs among the groups at any postoperative visit. Only Group B included cases with largely decentered IOLs, and the internal total HOAs in these cases were significantly larger than those in the others (P = 0.015). CONCLUSION Although largely decentered IOLs were occasionally found in Group B, aspheric IOLs could be effectively used in phacovitrectomy.
Collapse
Affiliation(s)
- Yasuaki Iwama
- Department of Ophthalmology, Osaka Rosai Hospital Clinical Research Center for Optical Sensory Organ Disability, 1179-3, Nagasone-cho, Kita-ku, Sakai, Osaka, 591-8025, Japan.
| | - Naoyuki Maeda
- Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Toshihide Ikeda
- Department of Ophthalmology, Osaka Rosai Hospital Clinical Research Center for Optical Sensory Organ Disability, 1179-3, Nagasone-cho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Hiroshi Nakashima
- Department of Ophthalmology, Osaka Rosai Hospital Clinical Research Center for Optical Sensory Organ Disability, 1179-3, Nagasone-cho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Kazuyuki Emi
- Department of Ophthalmology, Osaka Rosai Hospital Clinical Research Center for Optical Sensory Organ Disability, 1179-3, Nagasone-cho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| |
Collapse
|
25
|
Leisser C, Hirnschall N, Findl O. Effect of Air Tamponade on Tilt of the Intraocular Lens after Phacovitrectomy. Ophthalmologica 2019; 242:118-122. [PMID: 31085933 DOI: 10.1159/000499116] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Accepted: 02/25/2019] [Indexed: 11/19/2022]
Abstract
PURPOSE The aim of the study was to examine whether air tamponade has a significant effect on postoperative tilt of the intraocular lens (IOL) in combined phacoemulsification with implantation of an IOL and vitrectomy compared to balanced salt solution. PROCEDURES This randomized, controlled, monocentre study included patients scheduled for combined phacoemulsification with IOL implantation and pars plana vitrectomy. Patients were randomized for balanced salt solution or air tamponade. Postoperative tilt and decentration of the IOL were measured 2 months after surgery with a Purkinje meter. RESULTS Thirty-four patients were included into the analysis. Tilt of the IOL was on average 4.1 ± 1.9°, without significant differences between balanced salt solution and air tamponade (p = 0.462). Decentration of the IOL was on average 0.31 ± 0.14 mm, without significant differences between balanced salt solution and air tamponade (p = 0.42). CONCLUSIONS Air tamponade does not induce significantly more tilt or decentration of the IOL in combined phacoemulsification and vitrectomy compared to balanced salt solution. Potentially, this may not hold true for cases with a capsulorhexis that does not overlap the IOL optic.
Collapse
Affiliation(s)
- Christoph Leisser
- VIROS - Vienna Institute for Research in Ocular Surgery, Karl Landsteiner Institutes, Hanusch Hospital, Vienna, Austria
| | - Nino Hirnschall
- VIROS - Vienna Institute for Research in Ocular Surgery, Karl Landsteiner Institutes, Hanusch Hospital, Vienna, Austria
| | - Oliver Findl
- VIROS - Vienna Institute for Research in Ocular Surgery, Karl Landsteiner Institutes, Hanusch Hospital, Vienna, Austria,
| |
Collapse
|
26
|
Efficacy and safety of a new selective laser device to create anterior capsulotomies in cataract patients. J Cataract Refract Surg 2019; 45:601-607. [DOI: 10.1016/j.jcrs.2018.12.012] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Revised: 11/29/2018] [Accepted: 12/10/2018] [Indexed: 11/20/2022]
|
27
|
Abstract
PURPOSE OF REVIEW Continuous curvilinear manual capsulorhexis is currently the standard of cataract surgery. In the past several years, new technologies have been developed to improve the consistency and safety of capsulorhexis creation. This article reviews the most recent technologies in capsulotomy formation and their advantages and disadvantages. RECENT FINDINGS Guidance devices, femtosecond laser capsulotomy and precision pulse capsulotomy improve the centration, circularity and precision of anterior capsulorhexis and capsulotomy. These developments show particular promise for complex cataract surgeries, though clinical data on the refractive outcomes and complication rates of these technologies are currently limited and warrant additional investigation. SUMMARY New technological advances in capsulorhexis help surgeons achieve a more ideal capsulotomy geometry. Whether this translates into more predictable refractive outcomes and safer surgeries remains an area of future study.
Collapse
|
28
|
Daya SM, Chee SP, Ti SE, Packard R, Mordaunt DH. Parameters affecting anterior capsulotomy tear strength and distension. J Cataract Refract Surg 2018; 45:355-360. [PMID: 30509745 DOI: 10.1016/j.jcrs.2018.09.027] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Accepted: 09/16/2018] [Indexed: 11/29/2022]
Abstract
PURPOSE To study the effects of anterior capsulotomy diameter and discontinuity on tear threshold load and distension for the technique of continuous curvilinear capsulorhexis (CCC). SETTING Singapore National Eye Centre, Singapore, and CapsuLaser Inc., Livermore, California, USA. DESIGN Two separate randomized pairwise cadaver eye preclinical studies. METHODS Capsulotomies were performed in 40 cadaver eyes of 20 donors using CCC. The pairwise comparisons were divided into 2 study groups: Study A: Continuous versus discontinuous capsulotomies; Study B: Capsulotomy diameter of 5.0 mm and smaller versus diameters of 5.2 mm and larger. A shoe-tree method was used to apply load to the capsulotomy rim, and the Instron tensile stress instrument measured threshold load and distension to initiate a capsular tear. Wilcoxon matched-pairs signed-rank tests were performed to assess statistical superiority. RESULTS In Study Group A, all pairs demonstrated that continuous capsulotomies were better than discontinuous capsulotomies for both the anterior tear threshold load and distension (P < .01). In Study Group B, 80% of the pairs demonstrated that diameters of 5.2 mm and larger were better than those of 5.0 mm and smaller diameter (P < .05). CONCLUSIONS Anterior capsulotomies behave as nonlinear elastic (elastomeric) systems when exposed to an external load and distension. This study demonstrated that continuous circular capsulotomies were more resistant to anterior tears than discontinuous capsulotomies. A point of irregularity or a defect in a capsulotomy rim has a high probability of being the tear initiation point. Furthermore, larger diameter capsulotomies were more resistant to anterior tears than smaller capsulotomies.
Collapse
Affiliation(s)
- Sheraz M Daya
- Centre for Sight, East Grinstead, West Sussex, United Kingdom.
| | - Soon-Phaik Chee
- Singapore National Eye Centre, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; Singapore Eye Research Institute, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; Duke-NUS Medical School, Singapore
| | - Seng-Ei Ti
- Singapore National Eye Centre, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; Singapore Eye Research Institute, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; Duke-NUS Medical School, Singapore
| | - Richard Packard
- Arnott Eye Associates, London, United Kingdom; Singapore Eye Research Institute, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - David H Mordaunt
- Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; Excel-Lens, Inc., Los Gatos, California, USA
| |
Collapse
|
29
|
Wang L, Li P, Guo X. Comparison of diathermic high-frequency capsulorhexis and continuous curvilinear capsulorrhexis in white cataract surgery. Int J Ophthalmol 2018; 11:1317-1321. [PMID: 30140635 DOI: 10.18240/ijo.2018.08.11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2017] [Accepted: 05/30/2018] [Indexed: 11/23/2022] Open
Abstract
AIM To compare the corneal endothelial cell counts pre- and post-operation, ultrastructure of anterior lens capsule and surgical completion after diathermic high-frequency capsulorhexis (DHC) and continuous curvilinear capsulorrhexis (CCC) applied in phacoemulsification (PHACO) of white cataract surgery. METHODS Sixty-six eyes of 66 patients (33 males and 33 females) with cataract aged between 60 and 80y (mean 72.5±5.5) were recruited and undergone the surgery from June 2014 to November 2016. Anterior lens capsule, derived from two kinds of capsulorhexis, were randomly divided into two groups according to random number table. The ultrastructure of the capsule edge and its closer tissue were observed by transmission electron microscopy (TEM) and optical microscopy respectively. The surgical completion conditions and corneal endothelial cell counts were analyzed pre- and post-operation after two capsulorhexis. RESULTS The capsule derived from CCC had smooth edge, well-organized cellular structure and the cells filling into the cutting edge under TEM and optical microscopy. The capsule derived from DHC had an approximate 60 banded area of cell degeneration and necrosis, with dentiform prominences at the edge of the capsule, and no cell structure was observed at this area. The corneal endothelial cell counts of both groups were slightly declined 1wk post-operation compared with that of pre-operation. There was no statistical difference between the two groups (t=1.63, P>0.05). CONCLUSION DHC shows good clinical value in white mature and hypermature cataract surgery.
Collapse
Affiliation(s)
- Li Wang
- Department of Ophthalmology, Department of Medical and Research Technology Xi'an Medical University, Xi'an 710021, Shaanxi Province, China.,School of Public Health, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Peng Li
- Department of Ophthalmology, the 451st Hospital of the PLA, Xi'an 710054, Shaanxi Province, China
| | - Xiong Guo
- School of Public Health, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| |
Collapse
|