Hammer M, Britz L, Schickhardt S, Lieberwirth I, Munro D, Uhl P, Scheuerle A, Khoramnia R, Łabuz G, Auffarth GU. Quantification of Straylight Induced by Silicone Oil Adherent to Intraocular Lenses of Different Materials. Am J Ophthalmol 2024; 262:192-198. [PMID: 38016528 DOI: 10.1016/j.ajo.2023.11.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 11/17/2023] [Accepted: 11/17/2023] [Indexed: 11/30/2023]
Abstract
PURPOSE A complication of using silicone oil as an intraocular endotamponade is its adhesion to intraocular lenses (IOLs). Forward light scattering is a measure to quantify the optical disturbance caused by adherent oil droplets. We tested the straylight caused by silicone oil adhesion to different IOLs and examined whether an approved cleaning solution, F4H5, reverses the induced straylight. DESIGN An experimental study. METHODS Two hydrophobic acrylic IOL models and 1 hydrophilic model with a hydrophobic surface (n = 8 per model: 24 lenses) had straylight measured before contact with silicone oils, providing a baseline for subsequent testing: 12 lenses with lighter-than-water silicone oil (Siluron 2000) and 12 with heavier-than-water oil (Densiron 68). The final measurement was performed after cleansing with F4H5 when we used scanning electron and light microscopy to detect surface changes. RESULTS Straylight was majorly increased in IOLs with adherent silicone oil (baseline vs adherent oil median 3.1 [2.1, 3.9] and 39.7 [22.7, 87.8] deg2/sr, respectively; P < .001). No difference was seen between heavier- and lighter-than-water silicone oils. Between IOL types, induced straylight varied significantly, with 1 hydrophobic model reaching the highest average straylight. F4H5 significantly reduced straylight values in all IOL types (median 9.4 [5.4, 13.8] deg2/sr). The microscopy revealed surface changes on the IOLs even after cleaning. CONCLUSIONS Silicone oil adhesion to IOLs can induce amounts of straylight known to cause severe optical disturbance. F4H5 cleansing solution reversed straylight values to only slightly increased values. We found no difference in straylight formation between the lighter- and heavier-than-water silicone oils.
Collapse
Affiliation(s)
- Maximilian Hammer
- From the Department of Ophthalmology, University Clinic Heidelberg (M.H., L.B., A.S., R.K., G.Ł., G.U.A.); David J Apple Laboratory for Vision Research (M.H., L.B., S.S., D.M., A.S., R.K., G.Ł., G.U.A.)
| | - Leoni Britz
- From the Department of Ophthalmology, University Clinic Heidelberg (M.H., L.B., A.S., R.K., G.Ł., G.U.A.); David J Apple Laboratory for Vision Research (M.H., L.B., S.S., D.M., A.S., R.K., G.Ł., G.U.A.)
| | - Sonja Schickhardt
- David J Apple Laboratory for Vision Research (M.H., L.B., S.S., D.M., A.S., R.K., G.Ł., G.U.A.)
| | - Ingo Lieberwirth
- Heidelberg, Department of Physical Chemistry of Polymers, Max Planck Institute for Polymer Research, Mainz (I.L.)
| | - Donald Munro
- David J Apple Laboratory for Vision Research (M.H., L.B., S.S., D.M., A.S., R.K., G.Ł., G.U.A.)
| | - Philipp Uhl
- Institute for Pharmacy and Molecular Biotechnology, Heidelberg (P.U.), Germany
| | - Alexander Scheuerle
- From the Department of Ophthalmology, University Clinic Heidelberg (M.H., L.B., A.S., R.K., G.Ł., G.U.A.); David J Apple Laboratory for Vision Research (M.H., L.B., S.S., D.M., A.S., R.K., G.Ł., G.U.A.)
| | - Ramin Khoramnia
- From the Department of Ophthalmology, University Clinic Heidelberg (M.H., L.B., A.S., R.K., G.Ł., G.U.A.)
| | - Grzegorz Łabuz
- From the Department of Ophthalmology, University Clinic Heidelberg (M.H., L.B., A.S., R.K., G.Ł., G.U.A.); David J Apple Laboratory for Vision Research (M.H., L.B., S.S., D.M., A.S., R.K., G.Ł., G.U.A.)
| | - Gerd Uwe Auffarth
- From the Department of Ophthalmology, University Clinic Heidelberg (M.H., L.B., A.S., R.K., G.Ł., G.U.A.); David J Apple Laboratory for Vision Research (M.H., L.B., S.S., D.M., A.S., R.K., G.Ł., G.U.A.).
| |
Collapse
|
2
|
Łabuz G, Khoramnia R, Yan W, van den Berg TJTP, Auffarth GU, Naujokaitis T, Tandogan T. Characterizing glare effects associated with diffractive optics in presbyopia-correcting intraocular lenses. J Cataract Refract Surg 2024; 50:413-419. [PMID: 38237073 DOI: 10.1097/j.jcrs.0000000000001398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 01/08/2024] [Indexed: 03/26/2024]
Abstract
PURPOSE To objectively quantify glare of intraocular lenses (IOLs) using a diffractive principle to extend the visual range and to identify models with increased susceptibility to inducing glare. SETTING David J Apple Laboratory, Heidelberg, Germany. DESIGN Laboratory investigation. METHODS Glare was assessed by means of a straylight parameter with a standard C-Quant intended for 7 degrees. In addition, 2 C-Quant modifications were used to test lower angles (ie, 2.5 degrees and 3.5 degrees). The following IOL models were assessed: PanOptix, AT Lisa Tri, Synergy, and Triumf, the latter 2 with chromatic aberration correction at distance. Straylight from trifocal IOLs was compared against a monofocal W-60R lens. The C-Quant test was performed through the studied IOLs by using additional optical components attached to their ocular. RESULTS Straylight (deg 2 sr -1 ) of the control was <1 at all tested angles, with the trifocal models showing comparable straylight at 7 degrees. At 3.5 degrees, Triumf's straylight increased to 15.5 ± 0.6, followed by Synergy (6.2 ± 1.1), PanOptix (4.1 ± 0.3), and AT Lisa Tri (2.0 ± 0.8). The chromatic aberration-correcting models demonstrated correspondingly higher straylight (Synergy: 18.8 ± 1.3; Triumf: 17.3 ± 0.5) at 2.5 degrees compared with PanOptix (4.3 ± 0.4), AT Lisa Tri (2.1 ± 0.1), and monofocal IOLs yielding minimal or no increase. CONCLUSIONS Trifocal IOLs induced increased straylight, but it was limited to lower angles, which may cause difficulties detecting these effects using a standard clinical approach. The latest IOL designs featuring chromatic aberration correction at far focus seem more susceptible than the established trifocal IOLs to inducing a glare phenomenon.
Collapse
Affiliation(s)
- Grzegorz Łabuz
- From the The David J Apple Center for Vision Research, Department of Ophthalmology, University Hospital Heidelberg, Heidelberg, Germany (Łabuz, Khoramnia, Yan, Auffarth, Naujokaitis, Tandogan); Netherlands Institute for Neuroscience, Royal Netherlands Academy of Arts and Sciences, Amsterdam, the Netherlands (van den Berg); Augenklinik Pallas, Olten, Switzerland (Tandogan)
| | | | | | | | | | | | | |
Collapse
|
3
|
Hammer M, Muuss M, Schickhardt S, Scheuerle A, Khoramnia R, Łabuz G, Uhl P, Auffarth GU. Forward Light Scattering of the Vitreous Gel After Enzymatic Aging: An In Vitro Model to Study Vitreous Opacification. Invest Ophthalmol Vis Sci 2024; 65:36. [PMID: 38551585 PMCID: PMC10981431 DOI: 10.1167/iovs.65.3.36] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 03/04/2024] [Indexed: 04/01/2024] Open
Abstract
Purpose Symptomatic vitreous opacifications, so-called floaters, are difficult to objectively assess majorly limiting the possibility of in vitro studies. Forward light scattering was found previously to be increased in eyes with symptomatic floaters. Using an objective setup to measure forward light scattering, we studied the effects of enzymatically digesting the components of the vitreous body on straylight to develop an in vitro model of vitreous opacifications. Methods Fifty-seven porcine vitreous bodies were digested using hyaluronidase, collagenase, trypsin, and bromelain, as well as using a combination of hyaluronidase + collagenase and hyaluronidase + bromelain. A modified C-Quant setup was used to objectively assess forward light scattering. Results Depletion of hyaluronic acid majorly increased vitreous straylight (mean increase 34.4 deg2/sr; P = 0.01), whereas primarily digesting the vitreous gel with collagenase or trypsin did not significantly affect straylight. When collagenase or bromelain is applied in hyaluronic acid depleted vitreous gels, the increase in forward light scattering is reversed partially. Conclusions The age-related loss of hyaluronic acid primarily drives the increase in vitreous gel straylight induced by conglomerates of collagen. This process can be reversed partially by digesting collagen. This in vitro model allows the objective quantification and statistical comparison of straylight burden caused by vitreous opacities and, thus, can serve as a first testing ground for pharmacological therapies, as demonstrated with bromelain.
Collapse
Affiliation(s)
- Maximilian Hammer
- University Eye Clinic Heidelberg, Heidelberg, Germany
- The David J Apple Laboratory for Vision Research, Heidelberg, Germany
| | - Marcel Muuss
- University Eye Clinic Heidelberg, Heidelberg, Germany
- The David J Apple Laboratory for Vision Research, Heidelberg, Germany
| | - Sonja Schickhardt
- The David J Apple Laboratory for Vision Research, Heidelberg, Germany
| | | | | | - Grzegorz Łabuz
- University Eye Clinic Heidelberg, Heidelberg, Germany
- The David J Apple Laboratory for Vision Research, Heidelberg, Germany
| | - Philipp Uhl
- Institute for Pharmacy and Molecular Biotechnology, Heidelberg, Germany
| | - Gerd Uwe Auffarth
- University Eye Clinic Heidelberg, Heidelberg, Germany
- The David J Apple Laboratory for Vision Research, Heidelberg, Germany
| |
Collapse
|
4
|
Randomized multicenter trial to assess posterior capsule opacification and glistenings in two hydrophobic acrylic intraocular lenses. Sci Rep 2023; 13:2822. [PMID: 36805494 PMCID: PMC9938215 DOI: 10.1038/s41598-023-29855-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 02/11/2023] [Indexed: 02/19/2023] Open
Abstract
To evaluate the long-term posterior capsule opacification (PCO) formation, and glistening rate of the HOYA Vivinex (XY1) IOL compared to Alcon AcrySof (SN60WF). In this prospective, multicentric, randomized, paired-eye, open-label study, we included 87 subjects that underwent cataract surgery with IOL implantation, with 67 patients completing the 3-year follow-up. The completer population consisted of 32 subjects implanted with XY1 and 35 implanted with SN60WF. Primary endpoints consisted of the evaluation of glistenings and measurement of PCO. Secondary outcomes included Best Corrected Distance Visual Acuity (BCVA), Contrast Acuity (CA), uncorrected visual acuities, subjective refraction, medical and lens complication rates, adverse events, and optical/visual symptoms. Follow-up visits occurred at 6-months, 1-, 2- and 3-years. At 3-years follow-up, mean PCO score was 0.121 ± 0.193 for eyes implanted with Vivinex versus 0.239 ± 0.463 for AcrySof (p = 0.026). The Vivinex IOL showed statistically significantly lower glistening occurrence through 3-years postoperatively (0.14 ± 0.26) compared to AcrySof (1.79 ± 1.43; p < 0.0001). Postoperative visual acuities improved from baseline in both IOL groups (p < 0.0001), and remained stable through the 3-year follow-up period. Eyes implanted with a HOYA Vivinex IOL exhibited significantly lower occurrence of glistening at 3-years versus Alcon AcrySof (p < 0.0001). Incidence of PCO was very low and comparable in both Vivinex and AcrySof eyes.
Collapse
|
5
|
Optical function of intraocular lenses in different opacification patterns: metrology analysis of 67 explants. J Cataract Refract Surg 2021; 47:1210-1217. [DOI: 10.1097/j.jcrs.0000000000000553] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 12/05/2020] [Indexed: 11/25/2022]
|
6
|
Son HS, Łabuz G, Khoramnia R, Yildirim TM, Choi CY, Knorz MC, Auffarth GU. Visualization of Forward Light Scatter in Opacified Intraocular Lenses and Straylight Assessment. Diagnostics (Basel) 2021; 11:diagnostics11081512. [PMID: 34441445 PMCID: PMC8393541 DOI: 10.3390/diagnostics11081512] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 08/10/2021] [Accepted: 08/20/2021] [Indexed: 11/16/2022] Open
Abstract
Background: Qualitative visualization of forward light scatter and quantitative straylight measurement of intraocular lenses (IOLs). Methods: We analyzed two calcified IOL-explants, the Euromaxx ALI313Y (Argonoptics GmbH) and the LS-312 MF30 (Oculentis BV), one IOL with artificially induced glistenings (PC-60AD, Hoya), and one control (CT Asphina 409MP, Carl Zeiss Meditec AG) free of any opacification. Analysis included light microscopy, qualitative light scatter visualization using ray propagation imaging technique, and quantitative straylight measurement using C-Quant (Oculus). Results: More light scattering effect—visible as increased light intensity outside the IOL’s main focus—was evident in all opacified IOLs than the control. The highest straylight levels were observed in the Euromaxx (289.71 deg2/sr), which showed extensive granular deposits throughout its optic, followed by the MF30 (78.58 deg2/sr), which only showed opacification in its center. The glistenings-IOL demonstrated numerous microvacuoles within the optic and had straylight levels of 22.6 deg2/sr, while the control showed the lowest straylight levels (1.7 deg2/sr). Conclusions: Ray propagation imaging technique allowed qualitative assessment of off-axis veils of light that result from increased forward light scattering. Straylight was increased in all opacified lenses compared to the clear control lens. The IOL opacifications are significant sources of glare.
Collapse
Affiliation(s)
- Hyeck-Soo Son
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, 69117 Heidelberg, Germany; (H.-S.S.); (G.Ł.); (R.K.); (T.M.Y.); (C.Y.C.)
| | - Grzegorz Łabuz
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, 69117 Heidelberg, Germany; (H.-S.S.); (G.Ł.); (R.K.); (T.M.Y.); (C.Y.C.)
| | - Ramin Khoramnia
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, 69117 Heidelberg, Germany; (H.-S.S.); (G.Ł.); (R.K.); (T.M.Y.); (C.Y.C.)
| | - Timur M. Yildirim
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, 69117 Heidelberg, Germany; (H.-S.S.); (G.Ł.); (R.K.); (T.M.Y.); (C.Y.C.)
| | - Chul Young Choi
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, 69117 Heidelberg, Germany; (H.-S.S.); (G.Ł.); (R.K.); (T.M.Y.); (C.Y.C.)
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181, Korea
| | - Michael C. Knorz
- FreeVis LASIK Center, Medical Faculty Mannheim of the University of Heidelberg, 68167 Mannheim, Germany;
| | - Gerd U. Auffarth
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, 69117 Heidelberg, Germany; (H.-S.S.); (G.Ł.); (R.K.); (T.M.Y.); (C.Y.C.)
- Correspondence:
| |
Collapse
|
7
|
Alio JL, Arias A, D’Oria F, Toto F, Del Barrio JA, Duarte R, Artal P. Light scattering in intraocular lenses explanted 15 to 40 years after surgery. BIOMEDICAL OPTICS EXPRESS 2021; 12:3485-3494. [PMID: 34221674 PMCID: PMC8221949 DOI: 10.1364/boe.423652] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 04/28/2021] [Accepted: 05/13/2021] [Indexed: 06/13/2023]
Abstract
The optical quality of intraocular lenses (IOLs) of different materials that have been implanted from 16 to 44 years in human eyes was studied. The IOLs were explanted due to other causes than loss of transparency. The scattered light from the IOLs was assessed in two angular regimes by using dark field images (for wide angles) and the optical integration method (for narrower angles). No evident differences were found in the scattering intensities processed from the dark images. The explanted lenses presented slightly increased amounts of straylight between 1 and 5.1° when compared to a reference new unused lens.
Collapse
Affiliation(s)
- Jorge L. Alio
- Vissum innovation, Alicante, Spain
- Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain
| | - Augusto Arias
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), Murcia 30100, Spain
| | - Francesco D’Oria
- Vissum innovation, Alicante, Spain
- Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain
- Section of Ophthalmology, Department of Basic Medical Science, Neuroscience and Sense Organs, University of Bari, Bari, Italy
| | - Francesca Toto
- Vissum innovation, Alicante, Spain
- Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain
| | - Jorge Alio Del Barrio
- Vissum innovation, Alicante, Spain
- Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain
| | - Raul Duarte
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), Murcia 30100, Spain
| | - Pablo Artal
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), Murcia 30100, Spain
| |
Collapse
|
8
|
Yildirim TM, Łabuz G, Hammer M, Son HS, Schickhardt SK, Auffarth GU, Khoramnia R. A Novel Approach for Assessing Visual Impairment Caused by Intraocular Lens Opacification: High-Resolution Optical Coherence Tomography. Am J Ophthalmol 2021; 226:108-116. [PMID: 33571474 DOI: 10.1016/j.ajo.2021.02.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 01/16/2021] [Accepted: 02/02/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE To quantify in vitro straylight induced by intraocular lens (IOL) localized opacification using an anterior segment optical coherence tomography (OCT) device. DESIGN Laboratory investigation. METHODS We obtained high-resolution OCT cross-section images of 44 explanted IOLs using a new in vitro application for an anterior segment OCT device, the Anterion (Heidelberg Engineering, Heidelberg, Germany). In 24 cases, the reason for IOL explantation was a centrally localized opacification, the sequela of a secondary ocular surgery. As a control, we used 20 IOLs removed after an IOL (sub-)luxation. Using image analysis, we found a threshold area value representing a metric for the amount of opacification in a region of interest in the IOL's central optic. We used a modified C-Quant straylight meter (Oculus, Wetzlar, Germany) to quantify light scattering. We derived a linear regression from calculating the correlation between the amount of opacification and straylight. RESULTS We visualized different amounts of IOL opacification using the OCT device. The opacified lenses showed a mean threshold area of 6.7% ± 3.3% and mean straylight was 95.1 ± 75.6 deg2/sr. The clear group's mean threshold area was 2.0% ± 0.8% and 5.0 ± 3.4 deg2/sr mean straylight. Straylight correlated statistically significantly with the threshold area, with a correlation coefficient of R2 = 0.80, P < .001. CONCLUSIONS This high-resolution OCT imaging technique can be used to visualize IOL opacities. The amount of opacification correlated well with the straylight induced by the lens. Anterior segment OCT imaging might be used in the future as a tool for predicting the extent of visual impairment and aid clinicians to quantify patients' complaints.
Collapse
|
9
|
Iterative-Trained Semi-Blind Deconvolution Algorithm to Compensate Straylight in Retinal Images. J Imaging 2021; 7:jimaging7040073. [PMID: 34460523 PMCID: PMC8321324 DOI: 10.3390/jimaging7040073] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 04/13/2021] [Accepted: 04/14/2021] [Indexed: 01/19/2023] Open
Abstract
The optical quality of an image depends on both the optical properties of the imaging system and the physical properties of the medium in which the light travels from the object to the final imaging sensor. The analysis of the point spread function of the optical system is an objective way to quantify the image degradation. In retinal imaging, the presence of corneal or cristalline lens opacifications spread the light at wide angular distributions. If the mathematical operator that degrades the image is known, the image can be restored through deconvolution methods. In the particular case of retinal imaging, this operator may be unknown (or partially) due to the presence of cataracts, corneal edema, or vitreous opacification. In those cases, blind deconvolution theory provides useful results to restore important spatial information of the image. In this work, a new semi-blind deconvolution method has been developed by training an iterative process with the Glare Spread Function kernel based on the Richardson-Lucy deconvolution algorithm to compensate a veiling glare effect in retinal images due to intraocular straylight. The method was first tested with simulated retinal images generated from a straylight eye model and applied to a real retinal image dataset composed of healthy subjects and patients with glaucoma and diabetic retinopathy. Results showed the capacity of the algorithm to detect and compensate the veiling glare degradation and improving the image sharpness up to 1000% in the case of healthy subjects and up to 700% in the pathological retinal images. This image quality improvement allows performing image segmentation processing with restored hidden spatial information after deconvolution.
Collapse
|
10
|
Grzybowski A, Markeviciute A, Zemaitiene R. A narrative review of intraocular lens opacifications: update 2020. ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:1547. [PMID: 33313292 PMCID: PMC7729367 DOI: 10.21037/atm-20-4207] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The opacifications of intraocular lenses (IOLs) can significantly impact patients visual quality. Despite the identification of specific risk factors, manufacturing changes, opacifications are not eliminated. Likewise, more attention in recent studies was paid to possible new risk factors, however one of the most important purposes of the studies remains opacifications effect on visual performance, which could be disturbed in different aspects. The aim of this review is to discuss the main risk factors of IOLs opacification in particular IOL types, and its impact on vision quality. Different risk factors were discussed in the study, including the material of IOLs, the impact of the breakdown of blood-aqueous barrier (BAB), and certain surgeries that can be associated with opacification formation. Glistenings occur more often in a hydrophobic material, however, the changes in water content of the IOLs can significantly reduce the formation of glistenings. The studies showed a significant effect of intraocular injection of exogenous air or gas during Descemet-stripping endothelial keratoplasty, Descemet-stripping automated endothelial keratoplasty, Descemet membrane endothelial keratoplasty, and pars plana vitrectomy on calcification formation. It raises a concern, as the incidence of these surgeries is increasing. Visual acuity decreases significantly after the calcification in IOLs occurs, and it usually causes IOLs exchange. However, disability glare seems to be more affected in patients with IOLs, which were affected by glistenings than visual acuity. Disability glare is associated with increased levels of straylight, which was widely evaluated in recent studies and it was reported to be a susceptible measurement to detect the presence of IOLs pathology. For future researches, it should be noticed that disability glare and straylight are more appropriate in evaluating IOLs opacification effect on visual quality than visual acuity. While reviewing the main risk factors of IOLs opacifications particular attention must be paid on calcification occurrence in hydrophilic acrylic IOLs after surgeries with intraocular injection of exogenous air or gas.
Collapse
Affiliation(s)
- Andrzej Grzybowski
- Department of Ophthalmology, University of Warmia and Mazury, Olsztyn, Poland.,Institute for Research in Ophthalmology, Poznan, Poland
| | - Agne Markeviciute
- Department of Ophthalmology, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Reda Zemaitiene
- Department of Ophthalmology, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| |
Collapse
|
11
|
Affiliation(s)
- Andrzej Grzybowski
- Professor of Ophthalmology, Department of Ophthalmology, University of Warmia and Mazury, Olsztyn, Poland; Institute for Research in Ophthalmology, Poznan, Poland
| |
Collapse
|
12
|
Leydolt C, Schartmüller D, Schwarzenbacher L, Röggla V, Schriefl S, Menapace R. Posterior Capsule Opacification With Two Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial. Am J Ophthalmol 2020; 217:224-231. [PMID: 32335056 DOI: 10.1016/j.ajo.2020.04.011] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2020] [Revised: 04/14/2020] [Accepted: 04/14/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE To compare the incidence and intensity of posterior capsule opacification (PCO) and neodymium-yttrium-aluminum-garnet (Nd:YAG) capsulotomy rates between 2 similar open-loop single-piece hydrophobic acrylic intraocular lenses (IOLs) that differ in the proprietary material characteristics and design features, over a period of 3 years. DESIGN Randomized, prospective, patient- and examiner-masked clinical trial with intraindividual comparison. METHODS Setting: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. PATIENT POPULATION Eighty patients (160 eyes) had bilateral cataract surgery and received a Vivinex XY1 IOL in 1 eye and an AcrySof SN60WF IOL in the other eye. OBSERVATION PROCEDURES Follow-up examinations were performed 3 years after surgery. Digital retroillumination images were taken of each eye. The amount of PCO (score: 0-10) was assessed subjectively at the slit lamp and objectively using automated image analysis software (AQUA). MAIN OUTCOME MEASURE PCO score (scale, 0-10). RESULTS The mean objective PCO score of the Vivinex XY1 IOLs was 0.9 ± 0.8 compared to the PCO score of 1.4 ± 1.1 for the AcrySof SN60WF IOLs (P < .001). Three years postoperatively, 11.4% of patients had an Nd:YAG capsulotomy in the Vivinex XY1 eye and 18.6% had a capsulotomy in the AcrySof SN60WF eye (P = .23). CONCLUSION The new hydrophobic acrylic Vivinex XY1 IOL showed significantly lower PCO rates and lower YAG rates compared to the AcrySof SN60WF IOL. The interaction of various factors such as hydrophobic material, smooth optic surface, and sharp posterior optic edge plays a key role in PCO development.
Collapse
|
13
|
Łabuz G, Yildirim TM, van den Berg TJTP, Khoramnia R, Auffarth GU. Assessment of straylight and the modulation transfer function of intraocular lenses with centrally localized opacification associated with the intraocular injection of gas. J Cataract Refract Surg 2019; 44:615-622. [PMID: 29891155 DOI: 10.1016/j.jcrs.2018.01.033] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2017] [Revised: 11/11/2017] [Accepted: 01/24/2018] [Indexed: 10/28/2022]
Abstract
PURPOSE To assess the optical quality of intraocular lenses (IOLs) explanted because of opacification after the intraocular injection of gas. SETTING David J. Apple Laboratory, Heidelberg, Germany. DESIGN Experimental study. METHODS Four hydrophilic acrylic IOLs were studied, each with a centrally localized round opacification pattern associated with the intraocular use of gas. Laboratory analysis included gross examination with a light microscope, followed by alizarin and von Kossa staining. Optical quality was assessed by examining the modulation transfer function (MTF) and straylight. Results were compared with those of a control IOL and normative data for straylight of the crystalline lens. The following parameters were derived from image analysis: opacified surface fraction, light loss in the opacified surface, and the area and number of granules. The relationship between straylight increase and those parameters was studied. RESULTS Fine granules were identified on the IOL surface and subsurface. The granules stained positive for calcium, and the MTF levels of 2 IOLs dropped markedly. The other 2 showed relatively minor changes. The straylight was extremely increased in 3 IOLs up to (and above) a level of that of a cataractous lens. A proportional relationship was found between straylight and the morphological parameters from image analysis. CONCLUSIONS Intraocular lenses with centrally localized opacification have a strong potential for deteriorating optical performance. However, the optical quality might differ depending on the morphology of opacification. A serious straylight increase was found in most of these IOLs, suggesting that affected patients may suffer from glare-related symptoms.
Collapse
Affiliation(s)
- Grzegorz Łabuz
- From the David J. Apple Center for Vision Research, Department of Ophthalmology (Łabuz, Yildirim, Khoramnia, Auffarth), University Hospital Heidelberg, Heidelberg, Germany; the Netherlands Institute for Neuroscience (van den Berg), Royal Netherlands Academy of Arts and Sciences, Amsterdam, the Netherlands.
| | - Timur M Yildirim
- From the David J. Apple Center for Vision Research, Department of Ophthalmology (Łabuz, Yildirim, Khoramnia, Auffarth), University Hospital Heidelberg, Heidelberg, Germany; the Netherlands Institute for Neuroscience (van den Berg), Royal Netherlands Academy of Arts and Sciences, Amsterdam, the Netherlands
| | - Thomas J T P van den Berg
- From the David J. Apple Center for Vision Research, Department of Ophthalmology (Łabuz, Yildirim, Khoramnia, Auffarth), University Hospital Heidelberg, Heidelberg, Germany; the Netherlands Institute for Neuroscience (van den Berg), Royal Netherlands Academy of Arts and Sciences, Amsterdam, the Netherlands
| | - Ramin Khoramnia
- From the David J. Apple Center for Vision Research, Department of Ophthalmology (Łabuz, Yildirim, Khoramnia, Auffarth), University Hospital Heidelberg, Heidelberg, Germany; the Netherlands Institute for Neuroscience (van den Berg), Royal Netherlands Academy of Arts and Sciences, Amsterdam, the Netherlands
| | - Gerd U Auffarth
- From the David J. Apple Center for Vision Research, Department of Ophthalmology (Łabuz, Yildirim, Khoramnia, Auffarth), University Hospital Heidelberg, Heidelberg, Germany; the Netherlands Institute for Neuroscience (van den Berg), Royal Netherlands Academy of Arts and Sciences, Amsterdam, the Netherlands
| |
Collapse
|
14
|
Łabuz G, Knebel D, Auffarth GU, Fang H, van den Berg TJ, Yildirim TM, Son HS, Khoramnia R. Glistening Formation and Light Scattering in Six Hydrophobic-Acrylic Intraocular Lenses. Am J Ophthalmol 2018; 196:112-120. [PMID: 30189220 DOI: 10.1016/j.ajo.2018.08.032] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 08/16/2018] [Accepted: 08/24/2018] [Indexed: 11/28/2022]
Abstract
PURPOSE To study the glistening formation in various hydrophobic-acrylic intraocular lens (IOL) models, and to evaluate the effect of glistenings on light scattering in these IOLs. DESIGN Laboratory investigation. METHODS The susceptibility of the hydrophobic-acrylic material to develop glistenings was evaluated in 6 IOL models. Accelerated lens aging was induced by immersing the IOLs in a solution at 45 C for 24 hours and cooled to 37 C for 2.5 hours. Light microscopy and image acquisition were performed. Glistening statistics-that is, microvacuoles' (MV) number and size-were derived from image analysis. Light scattering was measured using a clinical device featuring an adaptation for in vitro IOL assessment. RESULTS The number of glistenings differed among the studied IOLs and ranged from 0 to 3532 MV/mm2. In 1 model, glistenings were found only at the periphery, with diffuse light scattering observed centrally despite the absence of microvacuoles. The mean size of glistenings ranged from 5.2 to 10.2 μm. The mean straylight parameter of the IOLs increased from 0.6 to 5.0 deg2/sr after accelerated aging. Straylight elevation demonstrated a proportional relationship with the glistening number. CONCLUSIONS We showed that hydrophobic-acrylic lenses differ in their resistance to glistenings, as one group proved to be glistening-free, but the other models revealed varying grades of glistenings. Moreover, we demonstrated that the presence of glistenings results in increased straylight, and that straylight proportionally depends on the glistenings number irrespective of the IOL model. However, more research is needed to confirm that the relationship we found holds for all hydrophobic-acrylic IOLs.
Collapse
Affiliation(s)
- Grzegorz Łabuz
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Dominik Knebel
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Gerd U Auffarth
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany.
| | - Hui Fang
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Thomas Jtp van den Berg
- Netherlands Institute for Neuroscience, Royal Netherlands Academy of Arts and Sciences, Amsterdam, Netherlands
| | - Timur M Yildirim
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Hyeck-Soo Son
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Ramin Khoramnia
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| |
Collapse
|