da Silva EM, Amaral CM, Jardim RN, Barbosa MP, Rabello TB. Influence of Specimen Dimension, Water Immersion Protocol, and Surface Roughness on Water Sorption and Solubility of Resin-Based Restorative Materials. MATERIALS (BASEL, SWITZERLAND) 2024; 17:984. [PMID: 38473457 DOI: 10.3390/ma17050984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 02/16/2024] [Accepted: 02/18/2024] [Indexed: 03/14/2024]
Abstract
The evaluation of water sorption and solubility is pivotal for the development of new resin-based restorative materials with the potential for clinical application. The purpose of the present study was to evaluate the influence of the specimen dimension, water immersion protocol, and surface roughness on the water sorption and solubility of three resin-based restorative materials. Disk-shaped specimens of 15 mm × 1 mm, 10 mm × 1 mm, and 6 mm × 1 mm were produced with a composite resin (Z100), a resin cement (RelyX ARC), and an adhesive system (Single Bond 2-SB2). The specimens were immersed in distilled water according to four protocols: ISO (all the specimens for each group were vertically immersed in 50 mL); IV-10 (the specimens were individually and vertically immersed in 10 mL); IH-10 (the specimens were individually and horizontally immersed in 10 mL); and IH-2 (the specimens were individually and horizontally immersed in 2 mL). The surface roughness (Sa and Sp) was evaluated using an atomic force microscope, and the degree of conversion was determined using FT-IR spectrometry. The specimen dimension and water immersion protocol had no effect on water sorption and solubility. For the three resin-based restorative materials, Sp was higher than Sa. The degree of conversion was not influenced by the specimen dimension. The variations in the specimen dimension and water immersion protocol compared to those determined by ISO 4049 did not prevent the comparison between the values of water sorption and solubility obtained for a given resin-based restorative material.
Collapse
Affiliation(s)
- Eduardo Moreira da Silva
- Analytical Laboratory of Restorative Biomaterials-LABiom-R, Faculdade de Odontologia, Universidade Federal Fluminense, Niterói 24040-110, Brazil
| | - Cristiane Mariote Amaral
- Analytical Laboratory of Restorative Biomaterials-LABiom-R, Faculdade de Odontologia, Universidade Federal Fluminense, Niterói 24040-110, Brazil
| | - Renata Nunes Jardim
- Analytical Laboratory of Restorative Biomaterials-LABiom-R, Faculdade de Odontologia, Universidade Federal Fluminense, Niterói 24040-110, Brazil
| | - Marianna Pires Barbosa
- Analytical Laboratory of Restorative Biomaterials-LABiom-R, Faculdade de Odontologia, Universidade Federal Fluminense, Niterói 24040-110, Brazil
| | - Tiago Braga Rabello
- Faculdade de Odontologia, Universidade Federal do Rio de Janeiro, Rio de Janeiro 21941-902, Brazil
| |
Collapse
|
2
|
Aoki R, Takamizawa T, Hayashi K, Arai Y, Ishii R, Shoji M, Kamimoto A, Miyazaki M. Influence of different curing modes on the bonding effectiveness of self-adhesive resin luting cements in combination with universal adhesives. Dent Mater 2024; 40:379-385. [PMID: 38176997 DOI: 10.1016/j.dental.2023.12.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 12/19/2023] [Indexed: 01/06/2024]
Abstract
OBJECTIVES This study aimed to investigate the immediate dentin bond performance and bond durability of self-adhesive resin luting cements (RLCs) in combination with universal adhesives in different curing modes. METHODS Two self-adhesive RLCs were used with universal adhesives as primers. They were also used alone as self-adhesive RLCs. Two multiple-step RLC systems were used as comparison materials. To measure the shear bond strength (SBS) in different curing modes, 12 specimens were prepared for each group. Stainless-steel rods were bonded to bovine dentin, and the bonded specimens were assigned to the baseline group (stored for 24 h) and artificially aged group (thermal cycling [TC], 10,000 cycles). After each storage period, the SBS of the bonded specimens was measured. The Knoop hardness number (KHN) of the cured RLCs was measured with or without primer application in different curing modes at 24 h and after 10,000 TC. The representative RLC/dentin interfaces were observed using scanning electron microscopy (SEM). RESULTS Dentin SBS was significantly influenced by the RLC system but not by the curing mode. Self-adhesive RLCs alone showed significantly lower SBS values than self-adhesive RLCs with primer regardless of the curing mode or storage period. The storage period, curing mode, and RLC system significantly influenced the KHN. SIGNIFICANCE The use of universal adhesives as a primer may help enhance the immediate dentin bond performance and bond durability of self-adhesive RLCs.
Collapse
Affiliation(s)
- Ryota Aoki
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Toshiki Takamizawa
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan.
| | - Kana Hayashi
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Yuiko Arai
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Ryo Ishii
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Mone Shoji
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Atsushi Kamimoto
- Department of Comprehensive Dentistry and Clinical Education, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Masashi Miyazaki
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| |
Collapse
|
3
|
Feng D, Dong S, Shi Z, Cui Z, Zhu S. Investigation of aging resistance for dental resin composites with and without glass flakes. Clin Oral Investig 2023; 27:6903-6914. [PMID: 37831194 DOI: 10.1007/s00784-023-05307-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Accepted: 10/03/2023] [Indexed: 10/14/2023]
Abstract
OBJECTIVES Outstanding physical-mechanical properties and aging resistance are key requirements for dental resin composite since it will be placed in the oral environment for a long time. In this work, a new dental resin composite mainly modified by glass flakes was fabricated, and the aging resistance was evaluated by comparing with commercial composites without glass flakes. MATERIALS AND METHODS The new dental resin composite was produced through hand blending of inorganic glass flakes/Si-Al-borosilicate glass (58wt%:7wt% of dental resin composite), POSS-MA (5wt% of resin matrix), Bis-GMA/TEGDMA(64.4wt%:27.6wt% of resin matrix), and CQ/EDMAB (0.9wt%:2.1wt% of resin matrix) together. The flexural strength, elasticity modulus, and hardness, as well as wear were tested for evaluating the aging resistance of different dental resin composite. RESULTS Among 6 kinds of commercial composites in this study, after 6-month water storage, the maximum percentage of performance degradation is that the flexural strength decreased 39.96%, elasticity modulus decreased 51.53% and hardness decreased 12.52%. In contrast, the new synthesized material decreased 14.53%, 20.88%, and 0.61%, respectively, and performed lesser wear depth compared to some other groups (P < 0.05). CONCLUSIONS It was observed that the new dental resin composite performed better performance stability and wear resistance when compared with commercial dimethacrylate-based or low shrinkage dental resin composite tested in this study. CLINICAL RELEVANCE This possibly paves a path for designing tailored dental composite for practical application. Since the aging resistance of dental resin composite modified by glass flakes is superior, it has the potential to be used for promoting the durability of dental resin composite.
Collapse
Affiliation(s)
- Dan Feng
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, Changchun, 130021, China
| | - Shujun Dong
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, Changchun, 130021, China
| | - Zuosen Shi
- State Key Lab of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, China
| | - Zhanchen Cui
- State Key Lab of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, China
| | - Song Zhu
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, Changchun, 130021, China.
| |
Collapse
|
4
|
Kasraei S, Haghi S, Farzad A, Malek M, Nejadkarimi S. Comparative of flexural strength, hardness, and fluoride release of two bioactive restorative materials with RMGI and composite resin. BRAZILIAN JOURNAL OF ORAL SCIENCES 2022. [DOI: 10.20396/bjos.v21i00.8665263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
Aim: This study was fulfilled to evaluate the flexural strength, micro-hardness, and release of two fluoride ions of bioactive restorative materials (Cention N and Activa Bioactive), a resin modified glass ionomer (Fuji II LC), and a resin composite (Filtek z250). Methods: Forty samples from four restorative materials (Activa Bioactive, Fuji II LC, Cention N, and Filtek Z250) were provided according to the current standards of ISO 4049/2000 guide lines. Subsequently, the samples were stored for 24 hours and 6 months in artificial saliva, and successively, flexural strength and micro-hardness of the samples were measured. For each studied groups the pH was decreased from 6.8 to 4 in storage solution. The rate of changes in fluoride ion release was measured after three different storage periods of 24 hours, 48 hours, and 6 months in distilled water, according to the previous studies’ method. Two-way ANOVA, One-way ANOVA, Tukey HSD Pair wise comparisons, and independent t-tests were used to analyze data (α= 0.05). Results: The highest flexural strength and surface micro-hardness after 24 hours and also after 6 month were observed for Cention N(p<0.001).Flexural strength of all samples stored for 6 months was significantly lower than the samples stored for 24 hours(p<0.001). The accumulative amount of the released fluoride ion in RMGI, after six-month storage period in distilled water was considerably higher (p<0.001) than 24 hours and 48 hours storage. The amount of fluoride ion release with increasing acidity of the environment (from pH 6.8 to 4) in Fuji II LC glass ionomer was higher than the bioactive materials (p<0.05). Conclusion: The flexural strength of RMGI was increased after storage against the Activa Bioactive,Cention N and Z250 composite. Storage of restorative materials in artificial saliva leads to a significant reduction in micro hardness. The behavior and amount of released fluoride ions in these restorative materials, which are stored in an acidic environment, were dependent on the type of restorative material.
Collapse
|
5
|
Ishii R, Takamizawa T, Katsuki S, Iwase K, Shoji M, Sai K, Tsujimoto A, Miyazaki M. Immediate bond performance of resin composite luting systems to saliva-contaminated enamel and dentin in different curing modes. Eur J Oral Sci 2022; 130:e12854. [PMID: 35072971 DOI: 10.1111/eos.12854] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2021] [Accepted: 01/07/2022] [Indexed: 11/29/2022]
Abstract
The purpose of this study was to evaluate the immediate shear bond strength of resin composite luting systems to tooth with or without saliva contamination in different curing modes. The Knoop hardness number of the resin composite luting agents was measured. Four combinations of resin composite luting systems were used. The shear bond strength to bovine teeth was measured with and without saliva contamination in different curing modes at different storage periods. The Knoop hardness number of the resin composite luting agents was also evaluated. Significantly lower enamel and dentin shear bond strengths and Knoop hardness number values were observed in all resin composite luting systems at 5 min versus 24 h, regardless of the curing mode or saliva contamination. The influence of the curing mode of the resin composite luting systems on shear bond strengths and Knoop hardness number was dependent on material. For the saliva contamination conditions, only G-CEM ONE EM did not show any significant difference in shear bond strength among the groups with and without saliva contamination, regardless of curing mode, storage period, or tooth substrate. All the resin composite luting systems showed lower shear bond strengths and Knoop hardness number values immediately after setting.
Collapse
Affiliation(s)
- Ryo Ishii
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Toshiki Takamizawa
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Shun Katsuki
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Kei Iwase
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Mone Shoji
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Keiichi Sai
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Akimasa Tsujimoto
- Department of Operative Dentistry, University of Iowa College of Dentistry, Iowa City, Iowa, USA
| | - Masashi Miyazaki
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| |
Collapse
|
6
|
de Resende LFM, Catelan A, Baroudi K, Palialol ARM, de Resende AM, Andreucci AC, Zanatta RF, Liporoni PCS. Mechanical Properties of Experimental Composites with Different Photoinitiator. Eur J Dent 2021; 16:167-172. [PMID: 34428844 PMCID: PMC8890916 DOI: 10.1055/s-0041-1731929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Objective
The effect of different photoinitiators on mechanical properties of experimental composites was evaluated.
Materials and Methods
Resin composites were formulated by using a blend of bisphenol A-glycidyl and triethylene glycol (50/50 wt%) dimethacrylate monomers, and 65 wt% of barium aluminium silicate and silica filler particles. Photoinitiators used were 0.2% camphorquinone (CQ) and 0.8% co-initiator (DMAEMA); 0.2% phenyl-propanedione and 0.8% DMAEMA; 0.1% CQ + 0.1% phenyl propanedione and 0.8% DMAEMA; 0.42% mono(acyl)phosphine oxide (MAPO); and 0.5% bis(acyl)phosphine oxide (BAPO). Specimens (
n
= 10) were light cured by using a multiple-emission peak light-emitting diode for 20 seconds at 1,200 mW/cm
2
of irradiance and Knoop hardness and plasticization, depth of cure, flexural strength, and elastic modulus were evaluated. Data were statiscally analyzed at significance level of α = 5%.
Results
Experimental composites containing MAPO and BAPO photoinitiators showed the highest values of flexural strength, elastic modulus, top surface hardness, and lower hardness reduction caused by alcohol compared with CQ. Composites containing CQ and PPD showed similar results, except for depth of cure and hardness of bottom surface.
Conclusion
BAPO and MAPO showed higher flexural strength, elastic modulus, hardness on top surface, and lower polymer plasticization to CQ.
Collapse
Affiliation(s)
| | - Anderson Catelan
- Department of Dentistry, Faculty of Health Sciences, University of Western São Paulo, Presidente Prudente, São Paulo, Brazil
| | - Kusai Baroudi
- School of Dentistry, University of Taubaté, Taubaté, São Paulo, Brazil
| | - Alan Rodrigo Muniz Palialol
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | | | | | | | | |
Collapse
|
7
|
Takamizawa T, Ishii R, Tamura T, Yokoyama M, Hirokane E, Tsujimoto A, Miyazaki M, Kitahara N. Handling properties and surface characteristics of universal resin composites. Dent Mater 2021; 37:1390-1401. [PMID: 34229866 DOI: 10.1016/j.dental.2021.06.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2021] [Accepted: 06/17/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE This study investigated the handling and surface characteristics of universal resin composites and determined the interrelations among the composites' handling, mechanical, and physical properties. METHODS Five recently introduced universal resin composites were tested. Twelve specimens per material were used to measure the stiffness and stickiness (handling properties) of the resin composite pastes. Additionally, surface properties (Knoop hardness number [KHN], surface roughness [Sa], surface gloss [SG], water contact angle [CA], and surface free energy [SFE]) of cured resin composites were determined in 12 specimens per material immediately after preparation (baseline) and after subjection to thermal cycles (TCs). RESULTS Handling and surface properties of the resin composites were material dependent. All the resin composites showed significantly lower KHN in the post-TC subgroups than that in the baseline subgroups. However, the influence of TC on the other surface properties was dependent on the material used. Some resin composites did not indicate any significant differences in Sa, SG, or CA between the baseline and post-TC groups. SIGNIFICANCE Although the resin composites in the baseline groups presented with different handling and surface properties, the surface properties of most of the composites were significantly affected by TC. Extremely strong positive or negative correlations were observed between stiffness and stickiness, KHN and Sa, KHN and SG, Sa and SG, and CA and SFE. Most correlations between the handling and surface properties were weak. Therefore, the selection of resin composites in clinical situations should be based on comprehensive consideration of their properties.
Collapse
Affiliation(s)
- Toshiki Takamizawa
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan.
| | - Ryo Ishii
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Tomohiko Tamura
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Munenori Yokoyama
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Eizo Hirokane
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Akimasa Tsujimoto
- Department of Operative Dentistry, University of Iowa College of Dentistry, Iowa City, IA, USA
| | - Masashi Miyazaki
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Nobuya Kitahara
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| |
Collapse
|
8
|
Pereira JR, Vidotti HA, Júnior LC, Vermudt A, de Souza Almeida M, Pamato S. Analysis of microleakage and marginal gap presented by new polymeric systems in class V restorations: An in vitro study. Saudi Dent J 2021; 33:156-160. [PMID: 33679109 PMCID: PMC7910649 DOI: 10.1016/j.sdentj.2019.11.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 11/11/2019] [Accepted: 11/13/2019] [Indexed: 11/23/2022] Open
Abstract
Objective Evaluating the contraction of polymerization effect of silorane-based composite on dental interface in enamel. Materials and Methods Eighty class V cavities were confectioned in forty extracted molar teeth and restored with different combinations of resinous-based and bond system. They were divided into the following groups: (G1) three-step etch-and-rinse adhesive system and methacrylate-based resin, (G2) two-step etch-and-rinse adhesive system and methacrylate-based resin, (G3) Filtek P-90 self-conditioning adhesive system and methacrylate-based resin, (G4) Adper SE Plus self-conditioning adhesive system and methacrylate-based resin, (G5) three-step etch-and-rinse adhesive system and silorane-based resin, (G6) two-step etch-and-rinse adhesive system and silorane-based resin, (G7) Filtek P-90 self-conditioning adhesive system and silorane-based resin, (G8) Adper SE Plus self-conditioning adhesive system and silorane-based resin. Results Group 7 showed lower marginal leakage when compared with all other groups (p = 0.001). Conclusions The results allows suggesting that silorane-based resinous system is adequate to promote more satisfactory marginal sealing than any other combination, since the system is combined with its own bond system.
Collapse
Affiliation(s)
| | | | - Lindomar Corrêa Júnior
- Department of Prosthodontics, University of Southern Santa Catarina, Tubarão, SC, Brazil
| | - Alef Vermudt
- Department of Prosthodontics, University of Southern Santa Catarina, Tubarão, SC, Brazil
| | - Mauro de Souza Almeida
- Department of Prosthodontics, University of Southern Santa Catarina, Tubarão, SC, Brazil
| | - Saulo Pamato
- Department of Health Sciences, University of Southern Santa Catarina, Tubarão, Brazil
| |
Collapse
|
9
|
Zhou X, Huang X, Li M, Peng X, Wang S, Zhou X, Cheng L. Development and status of resin composite as dental restorative materials. J Appl Polym Sci 2019. [DOI: 10.1002/app.48180] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Affiliation(s)
- Xinxuan Zhou
- State Key Laboratory of Oral DiseasesSichuan University Chengdu 610041 Sichuan China
- National Clinical Research Center for Oral DiseasesSichuan University Chengdu 610041 Sichuan China
| | - Xiaoyu Huang
- State Key Laboratory of Oral DiseasesSichuan University Chengdu 610041 Sichuan China
- Department of Operative Dentistry and Endodontics, West China Hospital of StomatologySichuan University Chengdu 610041 Sichuan China
- National Clinical Research Center for Oral DiseasesSichuan University Chengdu 610041 Sichuan China
| | - Mingyun Li
- State Key Laboratory of Oral DiseasesSichuan University Chengdu 610041 Sichuan China
- National Clinical Research Center for Oral DiseasesSichuan University Chengdu 610041 Sichuan China
| | - Xian Peng
- State Key Laboratory of Oral DiseasesSichuan University Chengdu 610041 Sichuan China
- National Clinical Research Center for Oral DiseasesSichuan University Chengdu 610041 Sichuan China
| | - Suping Wang
- Department of Operative Dentistry and Endodontics & Stomatology CenterThe First Affiliated Hospital of Zhengzhou University Zhengzhou 540052 Henan China
| | - Xuedong Zhou
- State Key Laboratory of Oral DiseasesSichuan University Chengdu 610041 Sichuan China
- Department of Operative Dentistry and Endodontics, West China Hospital of StomatologySichuan University Chengdu 610041 Sichuan China
- National Clinical Research Center for Oral DiseasesSichuan University Chengdu 610041 Sichuan China
| | - Lei Cheng
- State Key Laboratory of Oral DiseasesSichuan University Chengdu 610041 Sichuan China
- Department of Operative Dentistry and Endodontics, West China Hospital of StomatologySichuan University Chengdu 610041 Sichuan China
- National Clinical Research Center for Oral DiseasesSichuan University Chengdu 610041 Sichuan China
| |
Collapse
|
10
|
Abstract
This article aims to review the research done on the silorane-based resin composites (SBRC) regarding polymerization shrinkage and contraction stresses and their ability to improve the shortcomings of the methacrylate-based resin composites (MRBC). Special attention is given to their physical and mechanical properties, bond strength, marginal adaptation, and cusp deflection. The clinical significance of this material is critically appraised with a focus on the ability of SBRC to strengthen the tooth structure as a direct restorative material. A search of English peer-reviewed dental literature (2003-2015) from PubMed and MEDLINE databases was conducted with the terms "low shrinkage" and "silorane composites." The list was screened, and 70 articles that were relevant to the objectives of this work were included.
Collapse
|
11
|
Panahandeh N, Torabzadeh H, Naderi H, Sheikh-Al-Eslamian SM. Effect of water storage on flexural strength of silorane and methacrylate-based composite resins. Restor Dent Endod 2017; 42:309-315. [PMID: 29142879 PMCID: PMC5682147 DOI: 10.5395/rde.2017.42.4.309] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Accepted: 10/01/2017] [Indexed: 11/17/2022] Open
Abstract
Objectives This study assessed the effect of water storage on the flexural strength (FS) of low shrinkage composites. Materials and Methods A total of 165 bar-shaped specimens (2 × 2 × 25 mm) were fabricated of 2 low shrinkage composites (Filtek P90 [3M ESPE], GC Kalore [GC International]) and a conventional methacrylate-based composite (Filtek Z250 [3M ESPE]). The specimens were subjected to 3-point bending test at 6 time intervals, namely: immediately after curing, at 24 hours, 1 week, 1 month, 6 months, and 1 year following storage in wet and dry conditions. The FS of the specimens were measured by applying compressive load at a crosshead speed of 1.0 mm/min. Data was analyzed using 3-way analysis of variance (ANOVA) and Tukey's test. Results Three-way ANOVA revealed significant interactions between time, type of composite, and storage condition (p = 0.001). Tukey's multiple comparison test revealed significant reductions in FS of all composites after 6 months and 1 year of storage in distilled water compared to dry condition. Conclusions Filtek P90 showed the highest and GC Kalore showed the lowest FS after 1 year storage in distilled water. The immediate high strength of Filtek Z250 significantly decreased at 1 year and its final value was lower than that of Filtek P90.
Collapse
Affiliation(s)
- Narges Panahandeh
- Dental Research Center, Research Institute of Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Hassan Torabzadeh
- Dental Research Center, Research Institute of Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Hani Naderi
- Department of Periodontics, Mashhad University of Medical Sciences Faculty of Dentistry, Mashhad, Iran
| | | |
Collapse
|
12
|
Flury S, Diebold E, Peutzfeldt A, Lussi A. Effect of artificial toothbrushing and water storage on the surface roughness and micromechanical properties of tooth-colored CAD-CAM materials. J Prosthet Dent 2017; 117:767-774. [DOI: 10.1016/j.prosdent.2016.08.034] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2016] [Revised: 08/25/2016] [Accepted: 08/25/2016] [Indexed: 11/24/2022]
|
13
|
García-Contreras R, Scougall-Vilchis R, Acosta-Torres L, Arenas-Arrocena C, García-Garduño R, de la Fuente-Hernández J. Vickers microhardness comparison of 4 composite resins with different types of filler. JOURNAL OF ORAL RESEARCH 2015. [DOI: 10.17126/joralres.2015.061] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
14
|
Gazola EA, Rego MA, Brandt WC, D'Arce MBF, Liporoni PCS. Microhardness evaluation of silorane and methacrylate composites submitted to erosion and abrasion processes. ACTA BIOMATERIALIA ODONTOLOGICA SCANDINAVICA 2015. [PMID: 28642903 PMCID: PMC5433213 DOI: 10.3109/23337931.2015.1084884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Objective: The aim of this study was to evaluate the Knoop hardness number (KHN) of methacrylate (MC) and silorane (SC) composites after being submitted to erosion and abrasion processes. Material and methods: Forty samples were made with each composite: MC and SC. The samples were divided into eight groups (n = 10) according to the type of composite (G1-G4, MC; G5-G8, SC) and the beverages involved in the erosion process (G1 and G5 - Control (C), without erosion, with abrasion; G2 and G6 - Orange Juice (OJ), abrasion; G3 and G7 - Smirnoff Ice® (SI), abrasion; G4 and G8 - Gatorade® (GA), abrasion). The KHN test was performed 24 h after the last cycle of erosion/abrasion. Results: The MC groups showed smaller KHN values for the SI group (p < 0.05) when compared to the Control and OJ groups; however, for the SC groups, no differences were found (p > 0.05). Conclusion: Methacrylate composite when submitted to acidic beverages erosive challenge combined with abrasive process might alter its surface microhardness. However, the beverages used in the present study were not able to interfere in silorane composite surface microhardness.
Collapse
Affiliation(s)
- Eloá Aguiar Gazola
- Department of Restorative Dentistry, University of TaubatéTaubatéSão PauloBrazil
| | - Marcos Augusto Rego
- Department of Restorative Dentistry, University of TaubatéTaubatéSão PauloBrazil
| | | | | | - Priscila Christiane Suzy Liporoni
- Department of Restorative Dentistry, University of TaubatéTaubatéSão PauloBrazil.,Department of Restorative Dentistry, Piracicaba Dental School, UNICAMPPiracicabaSão PauloBrazil
| |
Collapse
|
15
|
Bolaños-Carmona V, Zein B, Menéndez-Núñez M, Sánchez-Sánchez P, Ceballos-García L, González-López S. Influence of the bracket on bonding and physical behavior of orthodontic resin cements. Dent Mater J 2015; 34:449-57. [PMID: 26235709 DOI: 10.4012/dmj.2014-315] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The aim of the study is to determine the influence of the type of bracket, on bond strength, microhardness and conversion degree (CD) of four resin orthodontic cements. Micro-tensile bond strength (µTBS) test between the bracket base and the cement was carried out on glass-hour-shaped specimens (n=20). Vickers Hardness Number (VHN) and micro-Raman spectra were recorded in situ under the bracket base. Weibull distribution, ANOVA and non-parametric test were applied for data analysis (p<0.05). The highest values of ή as well as the β Weibull parameter were obtained for metallic brackets with Transbond™ plastic brackets with the self-curing cement showing the worst performance. The CD was from 80% to 62.5%.
Collapse
|
16
|
Son SA, Park JK, Jung KH, Ko CC, Jeong CM, Kwon YH. Effect of 457 nm diode-pumped solid state laser on the polymerization composite resins: microhardness, cross-link density, and polymerization shrinkage. Photomed Laser Surg 2014; 33:3-8. [PMID: 25549163 DOI: 10.1089/pho.2014.3786] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVE The purpose of the present study was to test the usefulness of 457 nm diode-pumped solid state (DPSS) laser as a light source to cure composite resins. MATERIALS AND METHODS Five different composite resins were light cured using three different light-curing units (LCUs): a DPSS 457 nm laser (LAS), a light-emitting diode (LED), and quartz-tungsten-halogen (QTH) units. The light intensity of LAS was 560 mW/cm(2), whereas LED and QTH LCUs was ∼900 mW/cm(2). The degree of polymerization was tested by evaluating microhardness, cross-link density, and polymerization shrinkage. RESULTS Before water immersion, the microhardness of laser-treated specimens ranged from 40.8 to 84.7 HV and from 31.7 to 79.0 HV on the top and bottom surfaces, respectively, and these values were 3.3-23.2% and 2.9-31.1% lower than the highest microhardness obtained using LED or QTH LCUs. Also, laser-treated specimens had lower top and bottom microhardnesses than the other LCUs treated specimens by 2.4-19.4% and 1.4-27.8%, respectively. After ethanol immersion for 24 h, the microhardness of laser-treated specimens ranged from 20.3 to 63.2 HV on top and bottom surfaces, but from 24.9 to 71.5 HV when specimens were cured using the other LCUs. Polymerization shrinkage was 9.8-14.7 μm for laser-treated specimens, and these were significantly similar or lower (10.2-16.0 μm) than those obtained using the other LCUs. CONCLUSIONS The results may suggest that the 457 nm DPSS laser can be used as a light source for light-curing dental resin composites.
Collapse
Affiliation(s)
- Sung-Ae Son
- 1 Department of Conservative Dentistry, School of Dentistry, Pusan National University , Yangsan, Korea
| | | | | | | | | | | |
Collapse
|
17
|
Al Khuraif AAA. An in vitro evaluation of wear and surface roughness of particulate filler composite resin after tooth brushing. Acta Odontol Scand 2014; 72:977-83. [PMID: 25220522 DOI: 10.3109/00016357.2014.933251] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE To evaluate the influence of tooth brushing on wear and surface roughness of four different particulate filler composite resins. MATERIALS AND METHODS Six specimens (2 mm thick and 8 mm in diameter) of each tested material (Filtek Z250-Microhybrid, SpectrumTPH3-Submicron hybrid, Filtek Z350XT Nanofiller and Filtek P90- Microhybrid) were prepared according to the manufacturer's directions. A brushing sequence of 5000, 10,000 and 20,000 cycles was performed for all the samples. A non-contact profilometer was used to determine average surface roughness (Ra) and wear of the material assessed using an analytic electronic balance at baseline and each cycle interval. The data obtained were analyzed using one-way ANOVAs and post-hoc multiple comparison tests. Paired t-test was used for comparisons between cycle intervals for each material. Analyses with scanning electron microscopy (SEM) were also performed. RESULTS The resin composite Filtek P 90 presented an increase in percentage weight loss after final toothbrushing cycles over the rest of the materials. Brushing significantly increased roughness (Ra) for all composites. Filtek Z250, after brushing, was significantly rougher than the other resins followed by Filtek P 90, Spectrum TPH 3 and Filtek Z350 XT. However, SEM images indicated severe change in surface topography of 'sub-micron hybrid' specimen compared to each other after tooth brushing. CONCLUSIONS Wear and surface roughness increased with each cycle interval for all the materials and one composite resin demonstrated a higher increase in surface roughness than the other three tested brands of composite resins. Not much difference was observed in the weight loss between tested samples.
Collapse
Affiliation(s)
- Abdul Aziz A Al Khuraif
- Dental Health Department, College of Applied Medical Sciences, King Saud University , Riyadh , Saudi Arabia
| |
Collapse
|
18
|
Mousavinasab SM, Barekatain M, Sadeghi E, Nourbakhshian F, Davoudi A. Evaluation of light curing distance and mylar strips color on surface hardness of two different dental composite resins. Open Dent J 2014; 8:144-7. [PMID: 25228939 PMCID: PMC4160846 DOI: 10.2174/1874210601408010144] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2014] [Revised: 06/28/2014] [Accepted: 07/01/2014] [Indexed: 11/22/2022] Open
Abstract
Introduction: Hardness is one of the basic properties of dental materials, specially composite resins which is relevant to their polymerization. The aim of this study was to evaluate the effect of light curing distance and the color of clear Mylar strips on surface hardness of Silorane-based (SCR) and Methacrylate-based composite resins (MCR). Materials and methods: 40 samples of MCRs (Filtek Z250) and SCRs (Filtek P90) were prepared in size of 5 mm×2 mm (80 samples in total). The samples divided into 8 groups (10 samples in each one) based on the color of clear Mylar strips (white or blue) and distance from light curing source (0 mm or 2 mm). All the samples cured for 40 second and stored in incubator for 24 hours in 37°C temperature. Surface hardness test was done by Vickers test machine and the collected data were analyzed by one-way ANOVA and paired T-test by using SPSS software version 13 at significant level of 0.05. Results: MCRs cured with blue Mylar strips from 0 mm distance had the highest (114.5 kg/mm2) and SCRs cured with white Mylar strips from 2 mm distance had the lowest (42.2 kg/mm2) mean of surface hardness. Also, the results of comparison among SCRs and MCRs showed significant differences among all groups (all P values <0.01). Conclusion: The hardness decreased as the distance increased and the blue Mylar strips provided higher hardness than clear ones. Also, Filtek Z250 showed higher hardness compared to Filtek P90.
Collapse
Affiliation(s)
- Seyed Mostafa Mousavinasab
- Restorative Dentistry Department, Torabinejad Dental Research Center and Dental Materials Research Center, School of Dentistry, Isfahan University of Medical Sciences and Islamic Azad University (Khorasgan branch), Isfahan, Iran
| | - Mehrdad Barekatain
- Restorative Dentistry Department, Islamic Azad University (Khorasgan branch), Isfahan, Iran
| | - Elahe Sadeghi
- Graduated Dentistry Student, Islamic Azad University (Khorasgan branch), Isfahan, Iran
| | - Farzaneh Nourbakhshian
- Dentistry Student, Dental Students Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfa-han, Iran
| | - Amin Davoudi
- Dentistry Student, Dental Students Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfa-han, Iran
| |
Collapse
|
19
|
Walter R, Boushell LW, Heymann HO, Ritter AV, Sturdevant JR, Wilder AD, Chung Y, Swift EJ. Three-Year Clinical Evaluation of a Silorane Composite Resin. J ESTHET RESTOR DENT 2013; 26:179-90. [DOI: 10.1111/jerd.12077] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Ricardo Walter
- Department of Preventive and Restorative Sciences; University of Pennsylvania School of Dental Medicine; Philadelphia PA USA
| | - Lee W. Boushell
- Department of Operative Dentistry; University of North Carolina at Chapel Hill; Chapel Hill NC USA
| | - Harald O. Heymann
- Department of Operative Dentistry; University of North Carolina at Chapel Hill; Chapel Hill NC USA
| | - Andre V. Ritter
- Department of Operative Dentistry; University of North Carolina at Chapel Hill; Chapel Hill NC USA
| | - John R. Sturdevant
- Department of Operative Dentistry; University of North Carolina at Chapel Hill; Chapel Hill NC USA
| | - Aldridge D. Wilder
- Department of Operative Dentistry; University of North Carolina at Chapel Hill; Chapel Hill NC USA
| | - Yunro Chung
- Department of Biostatistics; University of North Carolina Gillings School of Global Public Health; Chapel Hill NC USA
| | - Edward J. Swift
- Department of Operative Dentistry; University of North Carolina at Chapel Hill; Chapel Hill NC USA
| |
Collapse
|