1
|
Yotsuya M, Nakano M, Umehara K, Awazawa S, Nomura T, Kuribayashi N, Yoshinari M, Sekine H. A Case of Anterior Single Tooth Implant with Fractured Zirconia Abutment due to Trauma. THE BULLETIN OF TOKYO DENTAL COLLEGE 2024; 65:31-40. [PMID: 38749760 DOI: 10.2209/tdcpublication.2023-0028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/10/2024]
Abstract
In recent years, a wide variety of materials have been used in dental implant treatment. In selecting the superstructures and abutments to be used it is important to consider their potential effect on the stability and durability of the planned implant. Excessive force applied to an implant during maintenance commonly results in complications, such as fracture of the superstructure or abutment, and loosening or fracture of the screws. This report describes a case of implant treatment for a 23-year-old man with esthetic disturbance due to trauma to the maxillary anterior teeth. The left maxillary central incisor could not be conserved due to this trauma, which had been caused by a traffic accident. After extraction, the tooth was restored with an anterior bridge. The crown of the left maxillary lateral incisor was fractured at the crown margin and, at the patient's request, implant treatment was selected as the restorative treatment for the missing tooth. A thorough preoperative examination was performed using placement simulation software. One titanium screw-type implant was placed in the maxillary left central incisor under local anesthesia. An all-ceramic crown with a zirconia frame was placed as a screw-fixed direct superstructure. At one year postoperatively, however, the superstructure and abutment became detached due to trauma. The fractured zirconia abutment was removed and replaced with a remanufactured abutment and superstructure. The patient has reported no subsequent dental complaint over the last 11 years. In this case, a surface analysis of the fractured zirconia abutment was performed. The scanned images revealed a difference in the fracture surfaces between the tensile and compressive sides, and electron probe microanalysis demonstrated the presence of titanium on the fracture surface. It was inferred that the hard zirconia abutment had scraped the titanium from the internal surface of the implant.
Collapse
Affiliation(s)
- Mamoru Yotsuya
- Department of Fixed Prosthodontics, Tokyo Dental College
| | - Masahiro Nakano
- Department of Fixed Prosthodontics, Tokyo Dental College
- Aomori Implant Research Group
| | - Kazuhiro Umehara
- Department of Fixed Prosthodontics, Tokyo Dental College
- Aomori Implant Research Group
| | | | | | | | | | - Hideshi Sekine
- Department of Fixed Prosthodontics, Tokyo Dental College
| |
Collapse
|
2
|
D'haese R, Vervack V, Tytgat M, Vandeweghe S. Fracture resistance of hybrid ceramic abutments with different restoration lengths: A pilot study. Clin Implant Dent Relat Res 2024; 26:615-620. [PMID: 38472145 DOI: 10.1111/cid.13322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 02/27/2024] [Accepted: 03/03/2024] [Indexed: 03/14/2024]
Abstract
AIM In this pilot study, the fracture resistance of hybrid abutments with different restoration lengths was investigated. MATERIALS AND METHODS Sixteen monolithic zirconia restorations of an upper right incisor were designed to fit a titanium base abutment. Eight central incisors had a crown length of 8 mm (T1) and the other half a length of 12 mm (T2). All crowns were cemented on the titanium base using a resin cement. After cementation, the samples were placed in a thermocycler for 5000 cycles. Fracture strength was measured using a universal test machine. Deformations and fractures of the samples were investigated. RESULTS The mean fracture resistance of T1 was 515 N (SD 96 N, 339-650) and 305 N (SD 57 N, 234-408) for T2 (p < 0.001). Both groups showed deformation of the titanium base, with no significant difference between both groups (p = 0.200). A difference in fracture type (p = 0.013) was observed, with significantly more screw fractures occurring in group T1 (p = 0.026). CONCLUSION Within the limitations of this study, hybrid restorations with standard titanium base abutments can withstand forces that have been associated with chewing, irrespective of the crown length. However, the shorter crowns demonstrated more fatal fractures.
Collapse
Affiliation(s)
- Rani D'haese
- Department of Reconstructive Dentistry, Dental School, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium
| | - Valentin Vervack
- Department of Reconstructive Dentistry, Dental School, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium
| | - Manon Tytgat
- Department of Periodontology, Dental School, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium
| | - Stefan Vandeweghe
- Department of Reconstructive Dentistry, Dental School, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium
| |
Collapse
|
3
|
Sadid-Zadeh R, Lin K, Li R, Nagy K. Fracture strength of screw-retained zirconia crowns assembled on zirconia and titanium implants. J Prosthodont 2024; 33:273-280. [PMID: 36973859 DOI: 10.1111/jopr.13683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 03/04/2023] [Accepted: 03/20/2023] [Indexed: 03/29/2023] Open
Abstract
PURPOSE This in vitro study evaluated the fracture strength of screw-retained zirconia crowns connected to zirconia (Zr) and titanium (Ti) implants after undergoing a simulation of 5 years of clinical use. MATERIALS AND METHODS Forty-eight screw-retained zirconia crowns were fabricated and assembled on four implant systems, with 12 in each group: (1) Zr implant (pure ceramic; Straumann AG) (PZr); (2) Zr implant (NobelPearl; Nobel Biocare) (NPZr); (3) Ti-Zr implant (Bone Level Roxolid; Straumann AG) (RSTiZr); (4) Ti implant (Conical Connection PMC; Nobel Biocare) (NRTi). Crowns were luted to their associated abutments using resin cement and then torqued to their assigned implants at the recommended torque value. Specimens were subjected to dynamic loading for 1,200,000 loading cycles. Fracture strength, measured in Newtons (N), was tested under static compression load using a universal testing machine at an angle of 30°. One-way ANOVA and Tukey's multiple comparisons post hoc test were used to compare the mean fracture values between the groups at a significance level of 0.05. RESULTS The average fracture strengths for the RSTiZr and NRTi groups were 1207 ± 202 and 1073 ± 217 N, respectively, which was significantly (p < 0.0001) higher than the PZr and NPZr groups (712 ± 76 and 571.6 ± 167 N, respectively). However, no significant difference was found between the fracture strength value of RSTiZr and NRTi (p = 0.260) or PZr and NPZr (p = 0.256) groups. CONCLUSIONS Zirconia crowns connected to Zr implants have the potential to withstand the average physiological occlusal forces which occur in the anterior and premolar regions.
Collapse
Affiliation(s)
- Ramtin Sadid-Zadeh
- Department of Restorative Dentistry, University at Buffalo School of Dental Medicine, Buffalo, New York, USA
| | - Kevin Lin
- Department of Restorative Dentistry, University at Buffalo School of Dental Medicine, Buffalo, New York, USA
| | - Rui Li
- Department of Restorative Dentistry, University at Buffalo School of Dental Medicine, Buffalo, New York, USA
| | - Katalin Nagy
- Head of Oral Surgery, Faculty of Dentistry, University of Szeged, Szeged, Hungary
| |
Collapse
|
4
|
Kohal RJ, Schikofski T, Adolfsson E, Vach K, Patzelt SBM, Nold J, Wemken G. Fracture Resistance of a Two-Piece Zirconia Implant System after Artificial Loading and/or Hydrothermal Aging-An In Vitro Investigation. J Funct Biomater 2023; 14:567. [PMID: 38132821 PMCID: PMC10743638 DOI: 10.3390/jfb14120567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 11/29/2023] [Accepted: 12/11/2023] [Indexed: 12/23/2023] Open
Abstract
The purpose of the present study was to assess the fracture resistance of a two-piece alumina-toughened zirconia implant system with a carbon-reinforced PEEK abutment screw. METHODS Thirty-two implants with screw-retained zirconia abutments were divided into four groups of eight samples each. Group 0 (control group) was neither loaded nor aged in a chewing simulator; group H was hydrothermally aged; group L was loaded with 98 N; and group HL was subjected to both hydrothermal aging and loading in a chewing simulator. One sample of each group was evaluated for t-m phase transformation, and the others were loaded until fracture. A one-way ANOVA was applied to evaluate differences between the groups. RESULTS No implant fracture occurred during the artificial chewing simulation. Furthermore, there were no statistically significant differences (p > 0.05) between the groups in terms of fracture resistance (group 0: 783 ± 43 N; group H: 742 ± 43 N; group L: 757 ± 86 N; group HL: 740 ± 43 N) and bending moment (group 0: 433 ± 26 Ncm; group H: 413 ± 23 Ncm; group L: 422 ± 49 Ncm; group HL: 408 ± 27 Ncm). CONCLUSIONS Within the limitations of the present investigation, it can be concluded that artificial loading and hydrothermal aging do not reduce the fracture resistance of the investigated implant system.
Collapse
Affiliation(s)
- Ralf-Joachim Kohal
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
| | - Tim Schikofski
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
| | - Erik Adolfsson
- RISE Research Institutes of Sweden, 431 53 Mölndal, Sweden;
| | - Kirstin Vach
- Medical Center—University of Freiburg, Institute for Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, 79104 Freiburg, Germany;
| | - Sebastian Berthold Maximilian Patzelt
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
- Private Dental Clinic, 78658 Zimmern ob Rottweil, Germany
| | - Julian Nold
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
| | - Gregor Wemken
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
| |
Collapse
|
5
|
Atalay P, Öztaş DD. Fatigue resistance and fracture strength of narrow-diameter one-piece zirconia implants with angled abutments. J ESTHET RESTOR DENT 2022; 34:1060-1067. [PMID: 35855644 DOI: 10.1111/jerd.12944] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 07/05/2022] [Accepted: 07/07/2022] [Indexed: 11/27/2022]
Abstract
OBJECTIVE Zirconia implants are assumed to satisfy the esthetic requirements that titanium implants cannot meet, however, there are not enough studies in the literature about narrow-diameter and angled zirconia implants that can be preferred especially in the anterior region. This in vitro study aimed to evaluate the fatigue resistance and fracture strength of narrow-diameter zirconia implants with angled abutments. MATERIALS AND METHODS Forty-eight one-piece experimental zirconia implants and monolithic zirconia crowns were produced from 3-YTZP blanks. The implant diameters (3.0 or 3.7 mm) and the restoration types were determined according to three intraoral regions (upper central incisors, lower central incisors, and upper canine), and abutments were designed as straight or 15° angled. The samples were subjected to chewing simulation corresponding to 5 years of clinical performance and then the static loading test. The survival rates of groups were measured by the Kaplan-Meier log-rank test, and the fracture load values were estimated by using Kruskal-Wallis and Mann-Whitney U tests (p < 0.05). RESULTS All 3.0 mm diameter implants failed the fatigue test. The fatigue resistance of the implants with angled abutments was significantly lower than the straight abutments, and different crown designs were found to affect survival rates significantly. The fracture strengths of the surviving groups were above the maximum physiological chewing forces, and the differences were not significant. CONCLUSIONS The implant diameter, abutment angle, and restoration type have a significant effect on the fatigue behavior of zirconia implants. CLINICAL SIGNIFICANCE The fracture strengths of the one-piece zirconia implants with a 3.7 mm diameter and a 15° abutment angle are above the chewing forces for the anterior intraoral region.
Collapse
Affiliation(s)
- Pelin Atalay
- Department of Prosthodontics, Faculty of Dentistry, University of Niğde Ömer Halisdemir, Niğde, Turkey
| | - Doğan Derya Öztaş
- Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara, Turkey
| |
Collapse
|
6
|
Liu M, Wang Y, Zhang S, Wei Q, Li X. Success Factors of Additive Manufactured Root Analogue Implants. ACS Biomater Sci Eng 2022; 8:360-378. [PMID: 34990114 DOI: 10.1021/acsbiomaterials.1c01079] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Dental implantation is an effective method for the treatment of loose teeth, but the threaded dental implants used in the clinic cannot match with the tooth extraction socket. A root analogue implant (RAI) has the congruence shape, which reduces the damage to bone and soft tissue. Additive manufacturing (AM) technologies have the advantages of high precision, flexibility, and easy operation, becoming the main manufacturing method of RAI in basic research. The purpose of this systematic review is to summarize AM technologies used for RAI manufacturing as well as the factors affecting successful implantation. First, it introduces the AM technologies according to different operating principles and summarizes the advantages and disadvantages of each method. Then the influences of materials, structure design, surface characteristics, implant site, and positioning are discussed, providing reference for designers and dentists. Finally, it addresses the gap between basic research and clinical application for additive manufactured RAIs and discusses the current challenges and future research directions for this field.
Collapse
Affiliation(s)
- Minyan Liu
- Department of Industry Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Yanen Wang
- Department of Industry Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Shan Zhang
- Department of Industry Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Qinghua Wei
- Department of Industry Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Xinpei Li
- Department of Industry Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| |
Collapse
|
7
|
Fracture Resistance of Zirconia Abutments with or without a Titanium Base: An In Vitro Study for Tapered Conical Connection Implants. MATERIALS 2022; 15:ma15010364. [PMID: 35009516 PMCID: PMC8746020 DOI: 10.3390/ma15010364] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 12/22/2021] [Accepted: 01/02/2022] [Indexed: 11/16/2022]
Abstract
Dental implants with tapered conical connections are often combined with zirconia abutments for esthetics; however, the effect of the titanium base on the implant components remains unclear. This study evaluated the effects of a titanium base on the fracture resistance of zirconia abutments and damage to the tapered conical connection implants. Zirconia (Z) and titanium base zirconia (ZT) abutments were fastened to Nobel Biocare (NB) implants and Straumann (ST) implants and subjected to static load testing according to ISO 14801:2016. The experiments were performed with 3 mm of the platform exposed (P3) and no platform exposed (P0). The fracture loads were statistically greater in the titanium base abutments than the zirconia abutments for the NB and ST specimens in the P0 condition. In the P3 condition of the ST specimens, the deformation volume of the ZT group was significantly greater than the Z group. The titanium base increased the fracture resistance of the zirconia abutments. Additionally, the titanium base caused more deformation in the P3 condition. The implant joint design may also affect the amount of damage to the implants when under a load. The mechanical properties of the abutment should be considered when selecting a clinical design.
Collapse
|
8
|
DESTE GÖKAY G, GÖKÇİMEN G, DURKAN R. Evaluation of Biomechanical Effects of Prosthetic Components with Different Materials on the Abutment Screw. CUMHURIYET DENTAL JOURNAL 2022. [DOI: 10.7126/cumudj.982237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
9
|
Rathe F, Junker R, Gröger S, Meyle J, Schlee M. Inflammatory effects of individualized abutments bonded onto titanium base on peri-implant tissue health: A randomized controlled clinical trial. Clin Implant Dent Relat Res 2021; 23:874-882. [PMID: 34668304 DOI: 10.1111/cid.13050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 08/29/2021] [Accepted: 09/28/2021] [Indexed: 12/20/2022]
Abstract
BACKGROUND In implant prosthodontics, computer-assisted design and computer-assisted manufacturing (CAD/CAM) zirconia abutments bonded onto titanium bases are frequently used in prosthetic dentistry. Unpolymerized monomer of the bonding material or the adhesive gap itself may have a negative effect on peri-implant tissue health. However, evidence addressing this problem is not available. PURPOSE The aim of the current trial was to study inflammatory effects of individualized abutments bonded onto titanium bases. MATERIAL AND METHOD A total of 24 patients with one test abutment and one control abutment each participated in this prospective, double-blind, randomized controlled clinical trial. Thereby, test abutments were CAD/CAM titanium abutments bonded onto titanium abutments (Ti-Base). As control abutments individualized, one-piece CAD/CAM titanium abutments were used. At abutment installation as well as 6 and 12 months thereafter bone level changes, clinical parameters as well as Il-1β levels were assessed. RESULTS Neither for bone level or clinical parameters nor for Il-1β levels, significant differences between test and control abutments could be found. However, in both groups Il-1β levels were significantly elevated at both the 6 and 12 months follow-up compared to baseline. CONCLUSION Within the limits of this RCT, it can be concluded that effects on the inflammatory state of peri-implant tissues do not differ between individualized abutments bonded onto Ti-Bases and individualized one-piece abutments.
Collapse
Affiliation(s)
- Florian Rathe
- Department of Prosthodontics and Biomaterials, DANUBE Private University, Krems an der Donau, Austria.,Private Office of Implantology and Periodontology, Forchheim, Germany
| | - Rüdiger Junker
- Department of Prosthodontics and Biomaterials, DANUBE Private University, Krems an der Donau, Austria
| | - Sabine Gröger
- Department of Periodontology, Justus Liebig-University, Gießen, Germany
| | - Jörg Meyle
- Department of Periodontology, Justus Liebig-University, Gießen, Germany
| | - Markus Schlee
- Private Office of Implantology and Periodontology, Forchheim, Germany.,Department of Maxillofacial Surgery, Johann Wolfgang von Goethe University, Frankfurt, Germany
| |
Collapse
|
10
|
Alonso-Pérez R, Bartolomé JF, Fraile C, Pradíes G. Original versus nonoriginal cast-to-gold abutment-implant connection: Analysis of the internal fit and long-term fatigue performance. J Prosthet Dent 2021; 126:94.e1-94.e9. [PMID: 34006366 DOI: 10.1016/j.prosdent.2021.03.020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 03/07/2021] [Accepted: 03/08/2021] [Indexed: 10/21/2022]
Abstract
STATEMENT OF PROBLEM Restoring implants with nonoriginal abutments is common. However, studies that evaluated compatible abutments with long-term fatigue performance are lacking. PURPOSE The purpose of this in vitro study was to assess the internal fit and the cyclic fatigue life after artificial aging of 3 implant-abutment configurations restored with 1 original and 2 compatible nonoriginal cast-to-gold abutments. MATERIAL AND METHODS Forty-eight original internal hexagon connection implants were connected to 3 different brands of abutments (n=16): 1 original to the implant system and the other 2 with nonoriginal abutments. Internal fit and the percentage of surface with tight contact were assessed by scanning electron microscopy in 12 cross-sectioned specimens (n=4) at 3 different areas (platform, internal, and screw). Thirty-six implant-abutment-crown specimens (n=12) were immersed in artificial saliva and thermocycled for 10 000 cycles between 5 °C and 55 °C. Subsequently, a cyclic load test, as per International Organization for Standardization (ISO) Standard 14 801, was completed in a universal testing machine at 2 Hz in air. RESULTS The original abutments presented the best fit and highest percentage of tight contact in the internal areas. In addition, the original abutments showed the lower cyclic fatigue strength degradation and the highest long-term success. CONCLUSIONS Occlusal loads are transferred more homogenously through the system when original abutments are used because of the better fit between the internal components, leading to increased fatigue resistance.
Collapse
Affiliation(s)
- Raquel Alonso-Pérez
- Researcher, Department of Buccofacial Prosthesis, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - José F Bartolomé
- Researcher, Instituto de Ciencia de Materiales de Madrid (ICMM), Consejo Superior de Investigaciones Científicas (CSIC), Madrid, Spain.
| | - Cristina Fraile
- Researcher, Department of Buccofacial Prosthesis, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Guillermo Pradíes
- Professor, Department of Buccofacial Prosthesis, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| |
Collapse
|
11
|
Semisch-Dieter OK, Choi AH, Ben-Nissan B, Stewart MP. Modifying an Implant: A Mini-review of Dental Implant Biomaterials. BIO INTEGRATION 2021. [DOI: 10.15212/bioi-2020-0034] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
Dental implants have been used as far back as 2000BC, and since then have developed into highly sophisticated solutions for tooth replacement. It is becoming increasingly important for the materials used in dental implants to exhibit and maintain favorable long-term mechanical, biological
and more recently, aesthetic properties. This review aims to assess the biomaterials used in modern dental implants, introducing their properties, and concentrating on modifications to improve these biomaterials. Focus is drawn to the prominent biomaterials, titanium (Ti) and zirconia due
to their prevalence in implant dentistry. Additionally, novel coatings and materials with potential use as viable improvements or alternatives are reviewed. An effective dental biomaterial should osseointegrate, maintain structural integrity, resist corrosion and infection, and not cause systemic
toxicity or cytotoxicity. Current materials such as bioactive glass offer protection against biofilm formation, and when combined with a titanium‐zirconium (TiZr) alloy, provide a reliable combination of properties to represent a competitive alternative. Further long-term clinical studies
are needed to inform the development of next-generation materials.Significance StatementBiomaterials have become essential for modern implants. A suitable implant biomaterial integrates into the body to perform a key function, whilst minimizing negative immune response. Focusing
on dentistry, the use of dental implants for tooth replacement requires a balance between bodily response, mechanical structure and performance, and aesthetics. This mini-review addresses the use of biomaterials in dental implants with significant comparisons drawn between Ti and zirconia.
Attention is drawn to optimizing surface modification processes and the additional use of coatings. Alternatives and novel developments are addressed, providing potential implications of combining biomaterials to form novel composites that combine and synergize the benefits of each material.
Collapse
Affiliation(s)
- Oliver K. Semisch-Dieter
- School of Life Sciences, Faculty of Science, University of Technology Sydney, Ultimo, NSW, Australia
| | - Andy H. Choi
- School of Life Sciences, Faculty of Science, University of Technology Sydney, Ultimo, NSW, Australia
| | - Besim Ben-Nissan
- School of Life Sciences, Faculty of Science, University of Technology Sydney, Ultimo, NSW, Australia
| | - Martin P. Stewart
- School of Life Sciences, Faculty of Science, University of Technology Sydney, Ultimo, NSW, Australia
| |
Collapse
|
12
|
Iijima N, Homma S, Nakano R, Hayashi S, Hirano T, Iijima T, Yajima Y. Fatigue properties of hollow zirconia implants. Dent Mater J 2021; 40:885-893. [PMID: 33692224 DOI: 10.4012/dmj.2020-248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The objective of this study was to clarify the fatigue behavior of hollow yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) specimens assuming its use for two-piece implants. The fatigue properties of a solid specimen (which simulated a one-piece implant) and 3 types of hollow specimens (which simulated two-piece implants) were evaluated. Specimens were either solid with a diameter of 4.0 mm (S) or hollow with an inner diameter of 3.0 mm and outer diameters of 4.0 mm (H0.5), 4.5 mm (H0.75), or 5.0 mm (H1.0). For each group, 25 specimens were prepared followed by blast and acid etch treatment. Static fracture and cyclic fatigue tests were conducted by modifying the methods provided in ISO6872. Fracture modes were determined by observing the surfaces under a scanning electron microscope. As a result, the cyclic fatigue load of S and H1.0 were similar, and hollow specimens with outer diameters greater than 0.75 mm displayed the ability to withstand molar occlusal forces.
Collapse
Affiliation(s)
- Noriko Iijima
- Department of Oral and Maxillofacial Implantology, Tokyo Dental College
| | - Shinya Homma
- Department of Oral and Maxillofacial Implantology, Tokyo Dental College
| | - Ryotaro Nakano
- Department of Oral and Maxillofacial Implantology, Tokyo Dental College
| | - Shota Hayashi
- Department of Oral and Maxillofacial Implantology, Tokyo Dental College
| | - Tomoki Hirano
- Department of Oral and Maxillofacial Implantology, Tokyo Dental College
| | - Toshihiko Iijima
- Department of Oral and Maxillofacial Implantology, Tokyo Dental College
| | - Yasutomo Yajima
- Department of Oral and Maxillofacial Implantology, Tokyo Dental College
| |
Collapse
|
13
|
Cárdenas R, Sánchez D, Euán R, Flores AM. Effect of fatigue loading and failure mode of different ceramic implant abutments. J Prosthet Dent 2021; 127:875-881. [PMID: 33483141 DOI: 10.1016/j.prosdent.2020.09.059] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 09/22/2020] [Accepted: 09/22/2020] [Indexed: 11/18/2022]
Abstract
STATEMENT OF PROBLEM Currently many options are available for restoring a dental implant, although the ideal implant abutment for withstanding the occlusal load and the restorative material for fulfilling the esthetic need remains unclear. Zirconia (Zir) abutments offer good esthetics, but concerns still remain regarding their fracture strength, complex fabrication, and higher cost as compared with those of titanium (Ti) base abutments offering lower cost, acceptable esthetics, and a straightforward procedure. PURPOSE The purpose of this in vitro study was to evaluate the fracture strength and failure mode of single-tooth Zir and Ti base implant abutments with fatigue loading. MATERIAL AND METHODS Forty restorations were included using 4 different types of abutment-restorations. Zir abutments with lithium disilicate crowns (ZirLd); titanium base abutments with custom Zir abutments and lithium disilicate crowns (TiZirLd); titanium base abutments with monolithic lithium disilicate abutment-crowns (TiLd); titanium base abutments with monolithic polymer-infiltrated ceramic abutment-crowns (TiEn). Specimens were subjected to a progressive cyclic loading by using a custom-made mastication simulator at a frequency of 1.4 Hz starting with a load of 88 N followed by stages of 170, 210, 250, and 290 N for a maximum of 20 000 cycles each or until fracture occurred. The number of cycles, maximum load, and failure modes were recorded. Statistical analysis was done by using the Mann-Whitney U test (α=.05). RESULTS Group TiEn showed a lower resistance to fatigue, with a mean ±standard deviation of 5054 ±123.3 cycles subjected to a mean force of 170 N. Groups ZirLd and TiLd resisted higher forces without fracture 13452.6 ±7094.3 cycles, and load of 178 ±16.9 N, followed by the TiLd group with a mean ±standard deviation of 25798.6 ±5498.7 cycles, and load of 202 ±16.9 N, while the TiZirLd group showed a mean of 48235.4 cycles subjected to a mean force of 258 N. The failure mode observed in the TiEn occurred only in the ceramic, whereas in the ZirLd and TiLd group, it was above the shoulder level of the Ti base abutment. Even though the TiZirLd group was able to withstand higher loads and a higher number of cycles, the failures were catastrophic and presented fractures of the titanium-base abutment and prosthetic screw. CONCLUSIONS The TiZirLd, ZirLd, and TiLd abutment-restorations have the potential to withstand the average physiological occlusal forces that occur in the anterior region. The group with the higher fatigue resistance was TiZirLd, although care should be taken with patients presenting parafunctional habits since the failure mode can be catastrophic. Also, polymer-infiltrated ceramic is not suitable for a Ti base abutment when subjected to oblique loading.
Collapse
Affiliation(s)
- Rubén Cárdenas
- Adjunct Professor, Department of Prosthodontics, Autonomous University of Nuevo León, Monterrey, Nuevo León, Mexico; Professor, Department of Restorative Dentistry, Autonomous University of Yucatán, Mérida, Yucatán, México
| | - Diana Sánchez
- Professor, Department of Prosthodontics, Autonomous University of Nuevo León, Monterrey, Nuevo León, Mexico
| | - Raúl Euán
- Chairman, Department of Prosthodontics, Autonomous University of Nuevo León, Monterrey, Nuevo León, Mexico.
| | - Arturo M Flores
- Professor, Department of Prosthodontics, Autonomous University of Nuevo León, Monterrey, Nuevo León, Mexico
| |
Collapse
|
14
|
Giner S, Bartolomé JF, Gomez-Cogolludo P, Castellote C, Pradíes G. Fatigue fracture resistance of titanium and chairside CAD-CAM zirconia implant abutments supporting zirconia crowns: An in vitro comparative and finite element analysis study. J Prosthet Dent 2020; 125:503.e1-503.e9. [PMID: 33243472 DOI: 10.1016/j.prosdent.2020.09.025] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 09/15/2020] [Accepted: 09/16/2020] [Indexed: 11/25/2022]
Abstract
STATEMENT OF PROBLEM Zirconia abutments with a titanium base are promising candidates to substitute for titanium abutments based on clinical studies reporting good short-term survival rates. However, information on the long-term performance of zirconia abutments supporting ceramic crowns is scarce. PURPOSE This in vitro comparative and finite element analysis study compared the fatigue life performance of ceramic computer-aided design and computer-aided manufacturing (CAD-CAM) monolithic restorations and zirconia abutments fabricated with a chairside workflow connected to a titanium interface versus titanium abutments. MATERIAL AND METHODS Twenty-two internal connection implants were divided into 2 groups, one with a zirconia abutment and monolithic ceramic zirconia crown (ZZ) and the other with a titanium abutment and zirconia crown (TiZ). They were subjected to a fatigue test to determine the fatigue limit and fatigue performance of each group as per International Organization for Standardization (ISO) 14801. Microstructural analysis of the fracture surfaces was conducted by using a scanning electron microscope (SEM). Simulations of the in vitro study were also conducted by means of finite element analysis (FEA) to assess the stress distribution over the different parts of the restoration. RESULTS The fatigue limit was 250 N for the TiZ group and 325 N for the ZZ group. In both groups, the screw was the part most susceptible to fatigue and was where the failure initiated. In the zirconia abutment models, the stress on the screw was reduced. CONCLUSIONS Chairside CAD-CAM zirconia abutments with a titanium base supporting zirconia crowns had higher fatigue fracture resistance compared with that of titanium abutments.
Collapse
Affiliation(s)
- Sergio Giner
- Researcher, Department of Buccofacial Prosthesis, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - José F Bartolomé
- Researcher, Instituto de Ciencia de Materiales de Madrid (ICMM), Consejo Superior de Investigaciones Científicas (CSIC), Madrid, Spain.
| | - Pablo Gomez-Cogolludo
- Associate Professor, Department of Buccofacial Prostheses, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain
| | - Carlos Castellote
- Professor, Department of Industrial and Aerospace Engineering, Faculty of Engineering, University Europea of Madrid, Madrid, Spain
| | - Guillermo Pradíes
- Professor and Head, Department of Buccofacial Prosthesis, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| |
Collapse
|
15
|
Zacher J, Bauer R, Hanie Krifka S, Rosentritt M. In vitro performance and fracture resistance of pressed or CAD/CAM milled ceramic implant-supported screw-retained or cemented anterior FDPs. J Prosthodont Res 2020; 65:208-212. [PMID: 32938865 DOI: 10.2186/jpr.jpor_2019_403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE This study investigated the in-vitro performance of anterior implant-supported fixed dental prostheses (FDP). The effect of ceramics, fabrication, finalization and the presence of a screw-channel wa s investigated. METHODS Identical anterior ceramic FDPs (tooth 11-13; n=80) were milled (Lithiumdisilicate (LiSiCAD, emaxCAD, Ivoclar-Vivadent), Lithiumaluminiumsilicate (LiAlSi, experimental material) or pressed (Lithiumdisilicate (LiSiPress, emaxPress, Ivoclar-Vivadent), Lithiumsilicate (ZLS, CeltraPress, Dentsply Sirona). FDP-groups (n=8 per material and group) simulated a cemented or screw-retained approach. After cementation or screwing on titanium abutments, thermal cycling and mechanical loading (TCML) was performed on all restorations to mimic 5-year clinical performance. Performance and fracture force were determined and failures were analyzed. STATISTICS (Kolmogorov-Smirnov-test, one-way-ANOVA; post-hoc-Bonferroni, multivariate-regression, α=0.05). RESULTS All FDPs survived TCML without aging, cracks, fractures or chipping. For FDPs without screw channel fracture values varied between with 839.8±112.3N (LiAlSi glazed) and 1485.9±232.6N (LiSiCAD). With screw channel, fracture results varied between 701.4±220.1N (LiALSi glazed) and 1516.3±253.7N (LiSipress). The type of material had a significant influence on the fracture results (LiSi>ZLS>LiAlSi; p≤0.012). Fabrication and finalization had no influence on the results. A screw channel did not significantly (p≥0.135) reduce the fracture force of the FDPs. Type of failure was mostly characterized by a fracture of the connector (LiSi, LiAlSi) or the abutment (ZLS, LiAlSi). CONCLUSIONS FDPs survived TCML without failures indicating that the in vitro performance was not influenced by the tested parameters. Composition of ceramic material has significant influence on the fracture resistance of implant supported LiSi based FDPs. Screw channel, fabrication or finalization did not weaken the FDPs.
Collapse
Affiliation(s)
- Julian Zacher
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg
| | - Robert Bauer
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg
| | - Step Hanie Krifka
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg
| | - Martin Rosentritt
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg
| |
Collapse
|
16
|
Joos M, Sailer I, Filippi A, Mukaddam K, Rosentritt M, Kühl S. Stability of screw-retention in two-piece zirconia implants: An in vitro study. Clin Oral Implants Res 2020; 31:607-614. [PMID: 32181927 DOI: 10.1111/clr.13597] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 03/05/2020] [Accepted: 03/12/2020] [Indexed: 11/27/2022]
Abstract
OBJECTIVES To compare the stability of a screw-retained connection in a novel two-piece zirconia implant to a conventional titanium-based connection in an in vitro chewing simulation including artificial ageing. MATERIAL AND METHODS Incisor (I) and molar (M) shaped monolithic zirconia crowns were screw-retained on either two-piece zirconia (test) or two-piece titanium (control) implants resulting in 4 groups of 8 samples (titanium implants with incisor-shaped crowns (T-I), titanium implants with molar-shaped crowns (T-M), zirconia implants with incisor-shaped crowns (Z-I) and zirconia implants with molar-shaped crowns (Z-M). These were subjected to artificial ageing by thermal cycling (TC: 2 × 3000 × 5°C/55°C cycles of 2 min) and mechanical loading (ML: 1.2 × 106 cycles of 50 N, f = 1 Hz). Surviving samples additionally underwent a fracture force test. Kaplan-Meier plots were drawn, and two-way ANOVA was calculated taking anatomical localisation and material variables as factors. RESULTS The mean corresponding survival times were lower for T-M (0.86 × 106 ± 0.31 × 106 cycles) and Z-I (0.84 × 106 ± 0.21 × 106 cycles) compared to T-I (1.14 × 106 ± 0.10 × 106 cycles) and Z-M (1.20 × 106 ± 0.10 × 106 cycles). In one-way ANOVAs for survival time dependent on either location or material, no statistically significant differences could be found (location: p = .31; material: p = .62) in one-way ANOVAs. The interaction of location and material showed significant differences (F = 21.3, p < .001). CONCLUSION The connection of the tested screw-retained zirconia crowns in two-piece zirconia implants is comparable to standard titanium implants in the specific in vitro testing.
Collapse
Affiliation(s)
- Marc Joos
- Department of Oral Surgery, University Center for Dental Medicine Basel (UZB), Basel, Switzerland
| | - Irena Sailer
- Division of Fixed Prosthodontics and Occlusion, University of Geneva, Geneva, Switzerland
| | - Andreas Filippi
- Department of Oral Surgery, University Center for Dental Medicine Basel (UZB), Basel, Switzerland
| | - Khaled Mukaddam
- Department of Oral Surgery, University Center for Dental Medicine Basel (UZB), Basel, Switzerland
| | - Martin Rosentritt
- Department of Prosthetic Dentistry, University Medical Center Regensburg, Regensburg, Germany
| | - Sebastian Kühl
- Department of Oral Surgery, University Center for Dental Medicine Basel (UZB), Basel, Switzerland
| |
Collapse
|
17
|
Zacher J, Bauer R, Strasser T, Rosentritt M. Laboratory performance and fracture resistance of CAD/CAM implant-supported tooth-coloured anterior FDPs. J Dent 2020; 96:103326. [PMID: 32201200 DOI: 10.1016/j.jdent.2020.103326] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 03/05/2020] [Accepted: 03/18/2020] [Indexed: 11/26/2022] Open
Abstract
OBJECTIVES This study investigated the in-vitro performance and fracture force of anterior implant-supported tooth-coloured fixed dental prosthesis (FDPs). Different material types with varying flexural strength and modulus of elasticity were compared with screw-retained or bonded application. MATERIALS AND METHODS Identical anterior FDPs (tooth 11-13; n = 80) from materials (flexural strength 240-1150 MPa, modulus 7.6-210 GPa; 1x lithiumdisilicate ceramic, 2x zirconia (4Y-TZP, 5Y-FSZ), 3x resin-based composites (with different flexural strength and modulus)) were milled. FDPs were grouped into chairside (bonded) and labside (screw-retained) procedure. To simulate a 5-year clinical application, thermal cycling with mechanical loading (TCML) was accomplished. TCML-performance and fracture force were evaluated and failure patterns were analysed. Data were statistically investigated (Kolmogorov-Smirnov-test, one-way-ANOVA; post-hoc-Bonferroni, α = 0.05). RESULTS TCML did not lead to any cracks, fractures or chipping on all tested FDPs. Fracture values varied between 1208.9 ± 354.6 N (experimental resin-based composite) and 2094.3 ± 293.4 N (4Y-TZP) for FDPs without screw channel. With screw channel the results ranged between 1297.9 ± 268.3 N (5Y-FSZ) and 2129.3 ± 321.7 N (4Y-TZP). The influence of the screw channel was not significant for all materials (p ≥ 0.218). Modulus of elasticity and flexural strength had influence on the fracture force only in the individual material groups. Fractures at the connector were predominant for ceramic and zirconia. Resin-based composites primarily showed radial fractures in abutment region or mixed failure types. FDPs with/without screw-channel showed comparable types of failure. CONCLUSIONS TCML did not lead to drop-outs or failures for all FDPs. Individual materials showed no different in-vitro performance, but varying fracture force after TCML. Independent from material, screw channels did not weaken the FDPs. All tested systems showed sufficient properties for an anterior implant application.
Collapse
Affiliation(s)
- Julian Zacher
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93042, Regensburg, Germany.
| | - Robert Bauer
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93042, Regensburg, Germany
| | - Thomas Strasser
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93042, Regensburg, Germany
| | - Martin Rosentritt
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93042, Regensburg, Germany
| |
Collapse
|
18
|
Bethke A, Pieralli S, Kohal RJ, Burkhardt F, von Stein-Lausnitz M, Vach K, Spies BC. Fracture Resistance of Zirconia Oral Implants In Vitro: A Systematic Review and Meta-Analysis. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E562. [PMID: 31991565 PMCID: PMC7040771 DOI: 10.3390/ma13030562] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 01/15/2020] [Accepted: 01/21/2020] [Indexed: 12/27/2022]
Abstract
Various protocols are available to preclinically assess the fracture resistance of zirconia oral implants. The objective of the present review was to determine the impact of different treatments (dynamic loading, hydrothermal aging) and implant features (e.g., material, design or manufacturing) on the fracture resistance of zirconia implants. An electronic screening of two databases (MEDLINE/Pubmed, Embase) was performed. Investigations including > 5 screw-shaped implants providing information to calculate the bending moment at the time point of static loading to fracture were considered. Data was extracted and meta-analyses were conducted using multilevel mixed-effects generalized linear models (GLMs). The Šidák method was used to correct for multiple testing. The initial search resulted in 1864 articles, and finally 19 investigations loading 731 zirconia implants to fracture were analyzed. In general, fracture resistance was affected by the implant design (1-piece > 2-piece, p = 0.004), material (alumina-toughened zirconia/ATZ > yttria-stabilized tetragonal zirconia polycrystal/Y-TZP, p = 0.002) and abutment preparation (untouched > modified/grinded, p < 0.001). In case of 2-piece implants, the amount of dynamic loading cycles prior to static loading (p < 0.001) or anatomical crown supply (p < 0.001) negatively affected the outcome. No impact was found for hydrothermal aging. Heterogeneous findings of the present review highlight the importance of thoroughly and individually evaluating the fracture resistance of every zirconia implant system prior to market release.
Collapse
Affiliation(s)
- Annalena Bethke
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
| | - Stefano Pieralli
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Felix Burkhardt
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Manja von Stein-Lausnitz
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
| | - Kirstin Vach
- Institute of Medical Biometry and Statistics, Faculty of Medicine, Medical Center—University of Freiburg, University of Freiburg, Stefan-Meier-Str. 26, 79104 Freiburg, Germany;
| | - Benedikt Christopher Spies
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| |
Collapse
|
19
|
Ferraz CC, Barros RM, Ferraz FC, Mundstock ÁA, Maior BS. Analysis of stress distribution in ceramic and titanium implants in alveolar sockets of the anterior region of the maxilla. J Clin Exp Dent 2019; 11:e850-e857. [PMID: 31636852 PMCID: PMC6797457 DOI: 10.4317/jced.55945] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Accepted: 07/30/2019] [Indexed: 11/05/2022] Open
Abstract
Background In the routine of dentistry, knowing the biomechanical properties of implant systems and their inherent stress distribution under force loading is an essential step to predict structural damage and biological responses. This study aimed to investigate stress distribution in zirconia and titanium implants and their biomechanical response in alveolar sockets of the anterior region of the maxilla through tridimensional finite element analysis. Material and Methods From computed tomography scans of a reference patient, three models of the maxillary dental arch were designed with Rhinoceros 5.0 software (McNeel Europe™, Barcelona, Spain). In each model, a dental implant replaced the maxillary left central incisor. The implants consisted of M1) Zirconia Pure Ceramic Implant Monotype; M2) Zirconia Pure Ceramic ZLA; and M3) Titanium Bone Level - Roxolid SLA. Ceramic crowns were installed in all the implants. Implants and prostheses were loaded with 50N oblique and axial forces. Von-Mises and Mohr Coulomb criteria were used to assess stress distribution in the implant systems and perimplantar bone, respectively. Results Traction was detected in the cervical region of the palatal bone surface of all the models. Oppositely, compression was found in the cervical region of the vestibular bone surfaces. Conclusions Zirconia Pure Ceramic Implant Monotype had the best response under oblique force loading. Ceramic implants may be an alternative to replace titanium implants in fresh alveolar sockets in the anterior region of the maxilla. Key words:Finite elements, implants, stress, ceramic, titanium.
Collapse
Affiliation(s)
- Cacilda-Cunha Ferraz
- Department of Dentistry, São Leopoldo Mandic Dental Research Center, rua Rua Marechal Floriano 600/1009, Centro, Governador Valadares/MG, Campinas - São Paulo -Brazil
| | - Rosália-Moreira Barros
- Department of Dentistry, São Leopoldo Mandic Dental Research Center, rua Rua Marechal Floriano 600/1009, Centro, Governador Valadares/MG, Campinas - São Paulo -Brazil
| | - Fábio-Cunha Ferraz
- Department of Dentistry, São Leopoldo Mandic Dental Research Center, rua Rua Marechal Floriano 600/1009, Centro, Governador Valadares/MG, Campinas - São Paulo -Brazil
| | - Átila-Augusto Mundstock
- Department of Dentistry, São Leopoldo Mandic Dental Research Center, rua Rua Marechal Floriano 600/1009, Centro, Governador Valadares/MG, Campinas - São Paulo -Brazil
| | - Bruno-Sotto Maior
- Department of Dentistry, São Leopoldo Mandic Dental Research Center, rua Rua Marechal Floriano 600/1009, Centro, Governador Valadares/MG, Campinas - São Paulo -Brazil
| |
Collapse
|
20
|
Fatigue survival and failure resistance of titanium versus zirconia implant abutments with various connection designs. J Prosthet Dent 2019; 122:315.e1-315.e7. [PMID: 31326150 DOI: 10.1016/j.prosdent.2019.05.036] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2019] [Revised: 05/27/2019] [Accepted: 05/28/2019] [Indexed: 11/24/2022]
Abstract
STATEMENT OF PROBLEM Data regarding the effect of connection design and abutment material on the fatigue survival and failure resistance of implant abutments are scarce. PURPOSE The purpose of this in vitro study was to investigate the effect of connection design and abutment material on the fatigue survival and failure resistance of implant abutment assemblies. MATERIAL AND METHODS Three types of implants (n=18, N=54) and 6 groups of abutments (n=9, N=54) with different connection designs-internal conical (IC), internal tri-channel (IT), and external hexagonal (EH)-and abutment materials-titanium (T) and zirconia (Z)-were investigated. All the abutments were restored with identical central incisor crowns. Fatigue testing, including thermal and mechanical aging, was performed in a mastication simulator (Esetron Smart Robotechnologies) for up to 1.2×106 cycles with a load of 50 N at an angle of 45 degrees. Then, the surviving specimens were subjected to failure resistance testing in a universal testing machine (Shimadzu AG-IS; Shimadzu Corp) at a crosshead speed of 1.0 mm/min. The maximum loads to failure (N) were recorded. Survival performance of the specimens throughout the fatigue testing was examined by the Kaplan-Meier survival analysis. The failure loads were analyzed by using the Kruskal-Wallis test followed by the Mann-Whitney U tests with Bonferroni-Holm correction (α=.05). RESULTS All the specimens of groups ICT, ITT, ITZ, and EHT survived fatigue testing, whereas 2 specimens from group ICZ and 3 specimens from EHZ failed. Statistically significant differences were found among the groups, based on the results of maximum failure loads (P<.05). The highest mean failure load was obtained in the ICT group (1069 ±182 N), followed by the ITT (926 ±197 N), EHT (873 ±126 N), ITZ (568 ±81 N), EHZ (311 ±45 N), and ICZ (287 ±63 N) groups. CONCLUSIONS Abutment material and connection design affected the fatigue survival of implant abutment assemblies. Implant abutment assemblies with a titanium-titanium interface revealed higher failure resistance than the implant abutment assemblies with a titanium-zirconia interface.
Collapse
|
21
|
Bankoglu Gungor M, Karakoca Nemli S, Yilmaz H, Aydin C. Fracture resistance of different implant supported ceramic abutment/crown systems. Eur Oral Res 2019; 53:80-87. [PMID: 31309198 PMCID: PMC6614687 DOI: 10.26650/eor.20199657] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Revised: 05/07/2018] [Accepted: 08/16/2018] [Indexed: 12/22/2022] Open
Abstract
Purpose The purpose of this study was to investigate the fracture resistance and failure modes of different non-aged and aged abutment/crown systems. Materials and methods One hundred dental implants (diameter 4.3 mm and length 11.5 mm) were restored with five abutment/crown systems: G1: a lithium disilicate hybrid abutment crown, G2: a lithium disilicate crown cemented on a lithium disilicate hybrid abutment, G3: a lithium disilicate crown cemented on a zirconia hybrid abutment, G4: a direct veneer porcelain layering on a zirconia hybrid abutment, and G5: a lithium disilicate crown cemented on a prefabricated all-zirconia abutment. Each group was divided into two groups (n=10) as control (non-aged) and thermomechanically aged. The fracture resistance test was performed. Failures during the aging process and after the fracture resistance test were examined. Results Both of the factors (restoration type and aging) affected the fracture resistance values and there was not an interaction between the factors (p>0.05). When fracture resistance values were compared regardless of aging, the highest values were observed in G3 and G4, respectively (p<0.05). When comparing the fracture resistance values, regardless of the restoration type, the aged group showed a significant lower fracture resistance value than control group (p<0.05). Conclusion A titanium base enhanced the fracture resistance of zirconia abutments. Thermomechanical aging decreased the fracture resistance of the tested ceramic abutment/crown systems. The major failure mode was the abutment fracture.
Collapse
Affiliation(s)
| | - Secil Karakoca Nemli
- Gazi University, Faculty of Dentistry, Department of Prosthodontics, Ankara,Turkey
| | - Handan Yilmaz
- Gazi University, Faculty of Dentistry, Department of Prosthodontics, Ankara,Turkey
| | - Cemal Aydin
- Gazi University, Faculty of Dentistry, Department of Prosthodontics, Ankara,Turkey
| |
Collapse
|
22
|
Gehrke SA, Prados-Frutos JC, Prados-Privado M, Calvo-Guirado JL, Aramburú Júnior J, Pérez-Díaz L, Mazón P, Aragoneses JM, De Aza PN. Biomechanical and Histological Analysis of Titanium (Machined and Treated Surface) Versus Zirconia Implant Materials: An In Vivo Animal Study. MATERIALS 2019; 12:ma12060856. [PMID: 30875729 PMCID: PMC6471506 DOI: 10.3390/ma12060856] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Revised: 03/04/2019] [Accepted: 03/12/2019] [Indexed: 11/16/2022]
Abstract
OBJECTIVES The aim of this study was to perform an in vivo histological comparative evaluation of bone formation around titanium (machined and treated surface) and zirconia implants. For the present study were used 50 commercially pure titanium implants grade IV, being that 25 implants with a machined surface (TiM group), 25 implants with a treated surface (TiT group) and, 25 implants were manufactured in pure zirconia (Zr group). The implants (n = 20 per group) were installed in the tibia of 10 rabbits. The implants distribution was randomized (n = 3 implants per tibia). Five implants of each group were analyzed by scanning electron microscopy and an optical laser profilometer for surface roughness characterization. Six weeks after the implantation, 10 implants for each group were removed in counter-torque for analysis of maximum torque value. The remaining samples were processed, included in historesin and cut to obtain non-decalcified slides for histomorphological analyses and histomorphometric measurement of the percentage of bone-implant contact (BIC%). Comparisons were made between the groups using a 5% level of significance (p < 0.05) to assess statistical differences. The results of removal torque values (mean ± standard deviation) showed for the TiM group 15.9 ± 4.18 N cm, for TiT group 27.9 ± 5.15 N cm and for Zr group 11.5 ± 2.92 N cm, with significant statistical difference between the groups (p < 0.0001). However, the BIC% presented similar values for all groups (35.4 ± 4.54 for TiM group, 37.8 ± 4.84 for TiT group and 34.0 ± 6.82 for Zr group), with no statistical differences (p = 0.2171). Within the limitations of the present study, the findings suggest that the quality of the new bone tissue formed around the titanium implants present a superior density (maturation) in comparison to the zirconia implants.
Collapse
Affiliation(s)
- Sergio Alexandre Gehrke
- Department of Research, Biotecnos, Cuareim 1483, Montevideo CP 11100, Uruguay.
- Department of Oral and Implant Surgery, Faculty of Health Sciences, Universidad Católica de Murcia (UCAM), 30107 Murcia, Spain.
- Instituto de Bioingenieria, Universidad Miguel Hernández, Avda. Ferrocarril s/n, 03202 Elche (Alicante), Spain.
| | - Juan Carlos Prados-Frutos
- Department of Medicine and Surgery, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, Spain.
| | - María Prados-Privado
- Department of Continuum Mechanics and Structural Analysis, Carlos III University, 28911 Madrid, Spain.
| | - José Luis Calvo-Guirado
- Department of Oral and Implant Surgery, Faculty of Health Sciences, Universidad Católica de Murcia (UCAM), 30107 Murcia, Spain.
| | - Jaime Aramburú Júnior
- Department of Surgery, Faculty of Veterinary, Faculty of Itapiranga, Itapiranga CP 89896000, Brazil.
| | - Leticia Pérez-Díaz
- Laboratorio de Interacciones Molecular, Facultad de Ciencias, Universidad de la Republica, Calle Iguá 4225, Montevideo 11400, Uruguay.
| | - Patricia Mazón
- Instituto de Bioingenieria, Universidad Miguel Hernández, Avda. Ferrocarril s/n, 03202 Elche (Alicante), Spain.
| | - Juan Manuel Aragoneses
- Department of Dental Research, Universidad Federico Henriquez y Carvajal (UFHEC), Santo Domingo 10107, Dominican Republic.
| | - Piedad N De Aza
- Instituto de Bioingenieria, Universidad Miguel Hernández, Avda. Ferrocarril s/n, 03202 Elche (Alicante), Spain.
| |
Collapse
|
23
|
Current status of zirconia implants in dentistry: preclinical tests. J Prosthodont Res 2018; 63:1-14. [PMID: 30205949 DOI: 10.1016/j.jpor.2018.07.006] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2017] [Revised: 07/18/2018] [Accepted: 07/26/2018] [Indexed: 11/23/2022]
Abstract
PURPOSE This systematic review aimed to provide an overview of zirconia implants as well as regarding the outcome of the implant-restorative complex in preclinical studies. STUDY SELECTION An electronic search of the literature prior to July 2017 was performed to identify all articles related to preclinical research on zirconia implants. The search was conducted using MEDLINE (National Library of Medicine) and PubMed without restrictions concerning the date of publication. The search terminology included: zirconia implant, osseointegration, bone-to-implant contact, soft tissue, histology, histomorphometry, surface modification, surface roughness, surface characteristics, and restoration (connecting multiple keywords with AND, OR). RESULTS Fifty-seven studies were finally selected from an initial yield of 654 titles, and the data were extracted. The identified preclinical studies focused on several aspects related to zirconia implants, namely biocompatibility, mechanical properties, implant design, osseointegration capacity, soft tissue response, and restorative options. Due to heterogeneity of the studies, a meta-analysis was not possible. The most frequently used zirconia material for the fabrication of implants is yttria-stabilized tetragonal zirconia polycrystal. The resistance-to-fracture for zirconia implants ranged between 516-2044N. The mostly investigated parameter was osseointegration, which is compared to that of titanium. A lack of evidence was found with other parameters. CONCLUSIONS Due to its good biocompatibility as well as favorable physical and mechanical properties, zirconia implants are a potential alternative to titanium implants. However, knowledge regarding the implant-restorative complex and related aspects is still immature to recommend its application for daily practice.
Collapse
|
24
|
Preis V, Hahnel S, Behr M, Rosentritt M. In vitro performance and fracture resistance of novel CAD/CAM ceramic molar crowns loaded on implants and human teeth. J Adv Prosthodont 2018; 10:300-307. [PMID: 30140397 PMCID: PMC6104500 DOI: 10.4047/jap.2018.10.4.300] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Revised: 03/07/2018] [Accepted: 05/08/2018] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To investigate the fatigue and fracture resistance of computer-aided design and computer-aided manufacturing (CAD/CAM) ceramic molar crowns on dental implants and human teeth. MATERIALS AND METHODS Molar crowns (n=48; n=8/group) were fabricated of a lithium-disilicate-strengthened lithium aluminosilicate glass ceramic (N). Surfaces were polished (P) or glazed (G). Crowns were tested on human teeth (T) and implant-abutment analogues (I) simulating a chairside (C, crown bonded to abutment) or labside (L, screw channel) procedure for implant groups. Polished/glazed lithium disilicate (E) crowns (n=16) served as reference. Combined thermal cycling and mechanical loading (TC: 3000×5℃/3000×55℃; ML: 1.2×106 cycles, 50 N) with antagonistic human molars (groups T) and steatite spheres (groups I) was performed under a chewing simulator. TCML crowns were then analyzed for failures (optical microscopy, SEM) and fracture force was determined. Data were statistically analyzed (Kolmogorow-Smirnov, one-way-ANOVA, post-hoc Bonferroni, α=.05). RESULTS All crowns survived TCML and showed small traces of wear. In human teeth groups, fracture forces of N crowns varied between 1214±293 N (NPT) and 1324±498 N (NGT), differing significantly (P≤.003) from the polished reference EPT (2044±302 N). Fracture forces in implant groups varied between 934±154 N (NGI_L) and 1782±153 N (NPI_C), providing higher values for the respective chairside crowns. Differences between polishing and glazing were not significant (P≥.066) between crowns of identical materials and abutment support. CONCLUSION Fracture resistance was influenced by the ceramic material, and partly by the tooth or implant situation and the clinical procedure (chairside/labside). Type of surface finish (polishing/glazing) had no significant influence. Clinical survival of the new glass ceramic may be comparable to lithium disilicate.
Collapse
Affiliation(s)
- Verena Preis
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, Regensburg, Germany
| | - Sebastian Hahnel
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, Regensburg, Germany
| | - Michael Behr
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, Regensburg, Germany
| | - Martin Rosentritt
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, Regensburg, Germany
| |
Collapse
|
25
|
Moilanen P, Hjerppe J, Lassila LVJ, Närhi TO. Fracture Strength and Precision of Fit of Implant-Retained Monolithic Zirconia Crowns. J ORAL IMPLANTOL 2018; 44:330-334. [PMID: 29763362 DOI: 10.1563/aaid-joi-d-17-00249] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
New monolithic zirconia materials can be used to fabricate full-contour fixed dental prostheses with the computer-aided design/computer-aided manufacturing (CAD/CAM) method. The aim of this study was to examine the fracture strength and precision of fit of screw-retained monolithic zirconia crowns made directly on implants or by cementing on prefabricated titanium (Ti) bases. Monolithic screw-retained implant crowns (n = 6) were produced by CAD/CAM method using partially (PSZ) and fully stabilized (FSZ) zirconia. Industrially produced zirconia crowns were used as a reference. A lateral incisor study model was made onto an implant replica. Crowns were produced either directly on the implant or through cementing on a prefabricated titanium base (PSZ+Ti, FSZ+Ti). The crowns were tightened to implant replicas with a torque of 35 Ncm. The gap between the replica and the abutment or crown was measured from ×400 scanning electron microscope images for precision of fit. Mechanical testing until failure was completed with a universal testing machine with loading angle of 45°. Statistical analysis was performed (analysis of variance). Mean (±SD) failure loads were 259 ± 23 (PSZ), 140 ± 13 (FSZ), 453 ± 25 (PSZ+Ti), 439 ± 41 (FSZ+Ti), and 290 ± 39 (Procera). Mean (±SD) gap values were 2.2 ± 0.2 (PSZ), 2.5 ± 1.0 (FSZ), 7.0 ± 1.0 (PSZ+Ti), 7.7 ± 1.6 (FSZ+Ti), and 6.7 ± 1.7 (Procera). Monolithic zirconia crowns with a Ti base clearly show higher fracture strengths than the crowns fixed directly on the implant surface. Better marginal fit can be achieved with direct zirconia crowns than with crowns on a titanium base or industrially produced zirconia crowns.
Collapse
Affiliation(s)
- Pauliina Moilanen
- 1 Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, Turku, Finland
| | - Jenni Hjerppe
- 1 Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, Turku, Finland.,2 Departments of Oral and Maxillofacial Diseases, Helsinki University Hospital, Helsinki, Finland
| | - Lippo V J Lassila
- 3 Turku Clinical Biomaterials Centre, University of Turku, Turku, Finland.,4 Turku University of Applied Sciences, Faculty of Health and Well-Being, Turku, Finland
| | - Timo O Närhi
- 1 Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, Turku, Finland.,5 Clinic of Oral Diseases, Turku University Central Hospital, Turku, Finland
| |
Collapse
|
26
|
Evaluation of Fatigue Behavior in Dental Implants from In Vitro Clinical Tests: A Systematic Review. METALS 2018. [DOI: 10.3390/met8050313] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
27
|
Ding Q, Zhang L, Bao R, Zheng G, Sun Y, Xie Q. Effects of different surface treatments on the cyclic fatigue strength of one-piece CAD/CAM zirconia implants. J Mech Behav Biomed Mater 2018; 84:249-257. [PMID: 29803139 DOI: 10.1016/j.jmbbm.2018.05.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2018] [Revised: 04/26/2018] [Accepted: 05/02/2018] [Indexed: 11/27/2022]
Abstract
OBJECTIVES The effects of different surface treatments on cyclic fatigue strengths of computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia implants and its mechanisms were evaluated. MATERIAL AND METHODS One-piece cylindrical screw-type zirconia (Y-TZP) implants with diameters of 4.1-mm were fabricated using CAD/CAM technique; they were divided into four groups according to the type of surface treatment: (i) sintering (control group, CTRL), (ii) sandblasting (SB), (iii) sandblasting and etching with an experimental hot etching solution (SB-ST), and (iv) sandblasting and etching with hydrofluoric acid (SB-HF). The surface morphology and roughness of the implants were evaluated. Tetragonal to monoclinic transformation was measured on the surface by micro Raman spectroscopy. Static and fatigue tests were carried out at room temperature following the ISO 14801:2014 Standard. The cyclic fatigue strength of each group was determined using the staircase method. Specimens that survived the fatigue test were statically loaded to measure the residual fracture strength. RESULTS Among the four groups, SB-HF exhibited the highest surface roughness. Compared with the CTRL group, the surface monoclinic content was higher after all three types of surface treatments, amongst which, SB-HF had the highest content (39.14%), significantly more than the other three groups (P < 0.01). The cyclic fatigue strengths of CTRL, SB, SB-ST, and SB-HF implants were 530 N, 662.5 N, 705 N, and 555 N, respectively. The fracture strength after fatigue loading was higher than that before fatigue loading with no significant difference (P>0.05). CONCLUSIONS SB and SB-ST remarkably enhanced the fatigue resistance of zirconia implants, while SB-HF did not. One-piece 4.1-mm diameter CAD/CAM zirconia implants have sufficient durability for application in dental implants.
Collapse
Affiliation(s)
- Qian Ding
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, 22 South Street ZhongGuanCun, Haidian District, Beijing 100081, China
| | - Lei Zhang
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, 22 South Street ZhongGuanCun, Haidian District, Beijing 100081, China.
| | - Rui Bao
- Institute of Solid Mechanics, School of Aeronautic Science and Engineering, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100191, China
| | - Gang Zheng
- Department of Dental Materials, Peking University School and Hospital of Stomatology; National Engineering Laboratory for Digital and Material Technology of Stomatology, Peking University, 22 South Street ZhongGuanCun, Haidian District, Beijing 100081, China
| | - Yuchun Sun
- Center of Digital Dentistry, Peking University School and Hospital of Stomatology; National Engineering Laboratory for Digital and Material Technology of Stomatology; Research Center of Engineering and Technology for Digital Dentistry, Ministry of Health, 22 South Street ZhongGuanCun, Haidian District, Beijing 100081, China
| | - Qiufei Xie
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, 22 South Street ZhongGuanCun, Haidian District, Beijing 100081, China
| |
Collapse
|
28
|
Elshiyab SH, Nawafleh N, Öchsner A, George R. Fracture resistance of implant- supported monolithic crowns cemented to zirconia hybrid-abutments: zirconia-based crowns vs. lithium disilicate crowns. J Adv Prosthodont 2018; 10:65-72. [PMID: 29503716 PMCID: PMC5829289 DOI: 10.4047/jap.2018.10.1.65] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2017] [Revised: 10/24/2017] [Accepted: 12/05/2017] [Indexed: 11/20/2022] Open
Abstract
PURPOSE The aim of this in vitro study was to investigate the fracture resistance under chewing simulation of implant-supported posterior restorations (crowns cemented to hybrid-abutments) made of different all-ceramic materials. MATERIALS AND METHODS Monolithic zirconia (MZr) and monolithic lithium disilicate (MLD) crowns for mandibular first molar were fabricated using computer-aided design/computer-aided manufacturing technology and then cemented to zirconia hybrid-abutments (Ti-based). Each group was divided into two subgroups (n=10): (A) control group, crowns were subjected to single load to fracture; (B) test group, crowns underwent chewing simulation using multiple loads for 1.2 million cycles at 1.2 Hz with simultaneous thermocycling between 5℃ and 55℃. Data was statistically analyzed with one-way ANOVA and a Post-Hoc test. RESULTS All tested crowns survived chewing simulation resulting in 100% survival rate. However, wear facets were observed on all the crowns at the occlusal contact point. Fracture load of monolithic lithium disilicate crowns was statistically significantly lower than that of monolithic zirconia crowns. Also, fracture load was significantly reduced in both of the all-ceramic materials after exposure to chewing simulation and thermocycling. Crowns of all test groups exhibited cohesive fracture within the monolithic crown structure only, and no abutment fractures or screw loosening were observed. CONCLUSION When supported by implants, monolithic zirconia restorations cemented to hybrid abutments withstand masticatory forces. Also, fatigue loading accompanied by simultaneous thermocycling significantly reduces the strength of both of the all-ceramic materials. Moreover, further research is needed to define potentials, limits, and long-term serviceability of the materials and hybrid abutments.
Collapse
Affiliation(s)
- Shareen H Elshiyab
- School of Dentistry and Oral Health, Griffith University, Gold Coast, Queensland, Australia.,Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Noor Nawafleh
- Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Andreas Öchsner
- School of Engineering, Griffith University, Gold Coast, Queensland, Australia
| | - Roy George
- School of Dentistry and Oral Health, Griffith University, Gold Coast, Queensland, Australia
| |
Collapse
|
29
|
In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns. Dent Mater 2017; 33:427-433. [DOI: 10.1016/j.dental.2017.01.003] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2016] [Revised: 12/21/2016] [Accepted: 01/18/2017] [Indexed: 10/20/2022]
|
30
|
Abstract
INTRODUCTION The use of zirconia in medicine and dentistry has rapidly expanded over the past decade, driven by its advantageous physical, biological, esthetic, and corrosion properties. Zirconia orthopedic hip replacements have shown superior wear-resistance over other systems; however, risk of catastrophic fracture remains a concern. In dentistry, zirconia has been widely adopted for endosseous implants, implant abutments, and all-ceramic crowns. Because of an increasing demand for esthetically pleasing dental restorations, zirconia-based ceramic restorations have become one of the dominant restorative choices. Areas covered: This review provides an updated overview of the applications of zirconia in medicine and dentistry with a focus on dental applications. The MEDLINE electronic database (via PubMed) was searched, and relevant original and review articles from 2010 to 2016 were included. Expert commentary: Recent data suggest that zirconia performs favorably in both orthopedic and dental applications, but quality long-term clinical data remain scarce. Concerns about the effects of wear, crystalline degradation, crack propagation, and catastrophic fracture are still debated. The future of zirconia in biomedical applications will depend on the generation of these data to resolve concerns.
Collapse
Affiliation(s)
- Yen-Wei Chen
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| | - Joelle Moussi
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| | - Jeanie L Drury
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| | - John C Wataha
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| |
Collapse
|
31
|
Fracture strength of implant abutments after fatigue testing: A systematic review and a meta-analysis. J Mech Behav Biomed Mater 2016; 62:333-346. [DOI: 10.1016/j.jmbbm.2016.05.011] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Revised: 05/06/2016] [Accepted: 05/09/2016] [Indexed: 11/27/2022]
|
32
|
Kammermeier A, Rosentritt M, Behr M, Schneider-Feyrer S, Preis V. In vitro performance of one- and two-piece zirconia implant systems for anterior application. J Dent 2016; 53:94-101. [PMID: 27528418 DOI: 10.1016/j.jdent.2016.08.004] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2016] [Revised: 08/09/2016] [Accepted: 08/11/2016] [Indexed: 11/29/2022] Open
Abstract
OBJECTIVES To investigate the long-term in vitro performance and fracture resistance of one-piece and bonded two-piece zirconia implant systems for anterior application. METHODS Two groups of bonded two-piece zirconia (ZZB), four groups of one-piece zirconia (Z), and two groups of two-piece titanium (TTS, reference) implant systems were restored with identical monolithic zirconia crowns (n=10/group). Eight specimens per group were mounted at an angle of 135° in the chewing simulator and subjected to thermal cycling (TC:18,000 cycles; 5°/55°) and mechanical loading (ML:3.6×10(6) cycles; 100N) simulating an anterior situation. Fracture resistance and maximum bending stress were determined for specimens that survived aging and for two references per group after 24h water storage. SEM pictures were used for failure analysis. Data were statistically analysed (one-way-ANOVA, post-hoc Bonferroni, Kaplan-Meier-Log-Rank, α=0.05). RESULTS A one-piece zirconia and a two-piece titanium implant system survived TCML without failures. Both bonded two-piece zirconia implant systems and a one-piece zirconia implant system totally failed (fractures of abutment or implant). Failure numbers of the other systems varied between 1× (1 group) and 5× (2 groups). Significantly different survival rates were found (Log-Rank-test: p=0.000). Maximum fracture forces/bending stresses varied significantly ( ANOVA p=0.000) between 188.00±44.80N/381.02±80.15N/mm(2) and 508.67±107.00N/751.45±36.73N/mm(2). Mean fracture values after 24h water storage and TCML were not significantly different. CONCLUSION Zirconia implant systems partly showed material defects or connection insufficiencies. Bonded two-piece systems had higher failure rates and lower fracture resistance than one-piece implants. CLINICAL SIGNIFICANCE Individual zirconia implant systems may be applied in anterior regions with limitations.
Collapse
Affiliation(s)
- Armin Kammermeier
- Department of Prosthetic Dentistry, Regensburg University Medical Center, Regensburg 93042, Germany
| | - Martin Rosentritt
- Department of Prosthetic Dentistry, Regensburg University Medical Center, Regensburg 93042, Germany
| | - Michael Behr
- Department of Prosthetic Dentistry, Regensburg University Medical Center, Regensburg 93042, Germany
| | - Sibylle Schneider-Feyrer
- Department of Prosthetic Dentistry, Regensburg University Medical Center, Regensburg 93042, Germany
| | - Verena Preis
- Department of Prosthetic Dentistry, Regensburg University Medical Center, Regensburg 93042, Germany.
| |
Collapse
|
33
|
Rosentritt M, Hahnel S, Engelhardt F, Behr M, Preis V. In vitro performance and fracture resistance of CAD/CAM-fabricated implant supported molar crowns. Clin Oral Investig 2016; 21:1213-1219. [DOI: 10.1007/s00784-016-1898-9] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Accepted: 06/27/2016] [Indexed: 11/28/2022]
|
34
|
Preis V, Kammermeier A, Handel G, Rosentritt M. In vitro performance of two-piece zirconia implant systems for anterior application. Dent Mater 2016; 32:765-74. [PMID: 27068740 DOI: 10.1016/j.dental.2016.03.028] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2015] [Revised: 02/03/2016] [Accepted: 03/22/2016] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To investigate the influence of the implant-abutment connection on the long-term in vitro performance and fracture resistance of two-piece zirconia implant systems for anterior application. METHODS Six groups of two-piece zirconia implant systems (n=10/group) with screw-retained (5×) or bonded (1×) connections were restored with full-contour zirconia crowns. A two-piece screw-retained titanium system served as reference. For simulating anterior loading the specimens (n=8/group) were mounted at an angle of 135° in the chewing simulator, and subjected to thermal cycling (TC: 2×9000×5°/55°C) and mechanical loading (ML: 3.6×10(6)×100N). Failed restorations were examined (scanning electron microscopy). Fracture resistance and maximum bending stress of surviving restorations were determined. 2 specimens per group were loaded to fracture after 24h water storage without TCML. Data were statistically analyzed (ANOVA; Bonferroni; Kaplan-Meier-Log-Rank; α=0.05). RESULTS The bonded zirconia system and the titanium reference survived TCML without any failures. Screw-retained zirconia systems showed fractures of abutments and/or implants, partly combined with screw fracture/loosening. Failure frequency (F) varied between the groups (F=8×: 3 groups, F=3×: 1 group, F=1×: 1 group). The Log-Rank-test showed significant (p=0.000) differences. Fracture forces and maximum bending stresses (mean±standard deviation) differed significantly ( ANOVA p=0.000) between 233.4±31.4N/317.1±42.6N/mm(2) and 404.3±15.1N/549.2±20.5N/mm(2). Fracture forces after TCML were similar to 24h fracture forces. SIGNIFICANCE Screw-retained two-piece zirconia implant systems showed higher failure rates and lower fracture resistance than a screw-retained titanium system, and may be appropriate for clinical anterior requirements with limitations. Failures involved the abutment/implant region around the screw, indicating that the connecting design is crucial for clinical success.
Collapse
Affiliation(s)
- Verena Preis
- Department of Prosthetic Dentistry, Regensburg University Medical Center, 93042 Regensburg, Germany.
| | - Armin Kammermeier
- Department of Prosthetic Dentistry, Regensburg University Medical Center, 93042 Regensburg, Germany
| | - Gerhard Handel
- Department of Prosthetic Dentistry, Regensburg University Medical Center, 93042 Regensburg, Germany
| | - Martin Rosentritt
- Department of Prosthetic Dentistry, Regensburg University Medical Center, 93042 Regensburg, Germany
| |
Collapse
|
35
|
Rosentritt M, Rembs A, Behr M, Hahnel S, Preis V. In vitro performance of implant-supported monolithic zirconia crowns: Influence of patient-specific tooth-coloured abutments with titanium adhesive bases. J Dent 2015; 43:839-45. [DOI: 10.1016/j.jdent.2015.04.011] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2014] [Revised: 04/18/2015] [Accepted: 04/23/2015] [Indexed: 11/16/2022] Open
|
36
|
Yilmaz B, Salaita LG, Seidt JD, Clelland NL, McGlumphy EA. Load to failure of different titanium abutments for an internal hexagon implant. J Prosthet Dent 2015; 114:513-6. [PMID: 26050025 DOI: 10.1016/j.prosdent.2015.04.012] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2014] [Revised: 04/28/2015] [Accepted: 04/28/2015] [Indexed: 10/23/2022]
Abstract
STATEMENT OF PROBLEM Several aftermarket abutments are available for a commonly used internal hexagonal connection implant. However, their load to failure performance is unknown when compared with the manufacturer's abutment. PURPOSE The purpose of this in vitro study was to conduct a load to failure comparison of 5 different titanium abutments (manufacturer's and aftermarket) for cement-retained restorations used on an implant with an internal hexagon connection. MATERIAL AND METHODS Five implants (Tapered Screw-Vent, 4.1×11.5 mm; Zimmer Dental) were individually secured in a loading apparatus, and 3 abutment specimens of each of the 5 different titanium abutments (Atlantis, AstraTech TiDesign, Legacy Straight Contoured, Inclusive Custom, and Zimmer PSA) (n=15 total) were loaded at a 30-degree angle until fracture of the implant abutment complex. Data for load to fracture were compared with analysis of variance and a Tukey-Kramer post hoc test (α=.05). RESULTS Significant differences were noted between the fracture loads of some abutment pairs; Atlantis-AstraTech TiDesign, Atlantis-Legacy Straight Contoured, AstraTech TiDesign-Legacy Straight Contoured, Inclusive Custom-AstraTech TiDesign, and Inclusive Custom-Legacy Straight Contoured (P<.05). The highest overall resistance to fracture was achieved by the Legacy Straight Contoured Abutment, which was significantly greater than all other aftermarket abutments (P<.05). Tested abutments fractured at an average of 649.17 N. The Zimmer PSA abutment was the only abutment that showed no fracture of any of the components before implant failure. CONCLUSION When comparing manufacturer's versus aftermarket brands, the manufacturer's abutment (Zimmer PSA) was the only abutment without fracture of any of the components. Aftermarket brands experienced screw fractures, which could result in further clinical prosthetic complications. The clinical implications of these findings need further investigation.
Collapse
Affiliation(s)
- Burak Yilmaz
- Associate Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, College of Dentistry, Columbus, Ohio.
| | | | - Jeremy D Seidt
- Research Scientist, Department of Mechanical and Aerospace Engineering, The Ohio State University, College of Engineering, Columbus, Ohio
| | - Nancy L Clelland
- Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, College of Dentistry, Columbus, Ohio
| | - Edwin A McGlumphy
- Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, College of Dentistry, Columbus, Ohio
| |
Collapse
|