1
|
Wyatt TD, Roberts HW. Simulated Hydrostatic Pulpal Pressure Effect on Microleakage-An Initial Study. Oper Dent 2024; 49:290-299. [PMID: 38632850 DOI: 10.2341/23-123-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/15/2023] [Indexed: 04/19/2024]
Abstract
PURPOSE This study's purpose was to evaluate the effect of simulated in vitro hydrostatic pulpal pressure (HPP) on microleakage. METHODS AND MATERIALS Extracted third molars (n=12) were sectioned 5 mm below the cementoenamel junction, pulp tissue removed, and the sectioned crowns mounted on a Plexiglas plate penetrated by an 18-gauge stainless steel tube. The mounted specimen mesial surface received a 2×4×6 mm Class V preparation followed by restoration with a strongly acidic, one-step dental adhesive and a flowable microfilled resin, following all manufacturers' instructions. Restorations were finished to contour, and tubing was attached to a 20-cm elevated, 0.2% rhodamine G reservoir to the specimen steel tube for 48 hours. Specimens then received a nail polish coating to within 1 mm of the restoration margins and were placed in 2% methylene blue (MB) dye for 24 hours, followed by rinsing, embedding in epoxy resin, and sectioning into 1 mm slices using a diamond saw. Controls were intact molars (n=12) processed as above but without HPP. Specimen slices were evaluated using laser confocal microscopy with images exported to ImageJ software with microleakage assessed as the MB linear penetration as a percentage of the total interfacial wall length. Mean values were evaluated with the Kruskal Wallis/Dunn test at a 95% confidence level. RESULTS The control specimens demonstrated significantly greater (p<0.0001) MB penetration than experimental specimens with simulated HPP. Under this study's conditions, simulated HPP significantly decreased MB dye penetration. CONCLUSION Studies accomplished without simulated HPP may overestimate microleakage results.
Collapse
Affiliation(s)
- T D Wyatt
- Taylor D Wyatt DMD, dental student, University of Kentucky College of Dentistry, Lexington, KY, USA
| | - H W Roberts
- *Howard W Roberts DMD MS, associate professor, University of Kentucky College of Dentistry, Lexington, KY, USA
| |
Collapse
|
2
|
Li Y, Maeno M, Cifuentes-Jimenez CC, Komoto M, Liu Y, Nara Y, Sano H, Alvarez-Lloret P, Yamauti M, Tomokiyo A. Effect of Simulated Dental Pulpal Pressure Using Fetal Bovine Serum for the Bonding Performance of Contemporary Adhesive to Dentin. Polymers (Basel) 2024; 16:1219. [PMID: 38732688 PMCID: PMC11085566 DOI: 10.3390/polym16091219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 04/23/2024] [Accepted: 04/23/2024] [Indexed: 05/13/2024] Open
Abstract
This study evaluated the effect of simulated pulpal pressure (SPP) conditions and storage time on contemporary adhesive systems' microtensile bond strength (µTBS) to dentin. Extracted human molars were prepared and randomly divided into four groups according to the adhesives: Clearfil Megabond 2 (CSE), Beautibond Xtreme Universal (BXU), G2-Bond (G2B), and Scotchbond Universal Plus (SBP). Each adhesive group was further divided following the SPP conditions: control with no simulation (SPP-CTR), SPP with distilled water (SPP-DTW), and SPP with fetal bovine serum (SPP-FBS). Resin composite build-ups were prepared, and teeth were stored in water (37 °C) for 24 h (24 h) and 3 months (3 m). Then, teeth were sectioned to obtain resin-dentin bonded beams and tested to determine the µTBS. Data were analyzed using three-way ANOVA, Tukey post hoc tests (=0.05), and Weibull failure analysis. Failure mode was observed using scanning electron microscopy. The µTBS response was affected by adhesive systems, simulated pulpal pressure conditions, and storage time. SPP-CTR groups presented a higher overall bond strength than SPP-DTW and SPP-FBS, which were not significantly different from each other. Only for SBP, the SPP-FBS group showed higher µTBS than the SPP-DTW group. The Weibull analysis showed that the bonding reliability and durability under SPP-DTW and SPP-FBS were inferior to SPP-CTR, and the 24 h bonding quality of adhesives to dentin was superior to that of 3 m. SPP drastically reduced the µTBS of all adhesives to dentin regardless of solution (distilled water or fetal bovine serum). Storage after 3 m also decreased µTBS despite the SPP condition.
Collapse
Affiliation(s)
- Yitong Li
- Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Sapporo 060-8586, Japan; (Y.L.); (Y.L.); (H.S.); (A.T.)
| | - Masahiko Maeno
- Department of Adhesive Dentistry, School of Life Dentistry at Tokyo, The Nippon Dental University, 1-9-20, Fujimi, Chiyoda-ku, Tokyo 102-8159, Japan (M.K.); (Y.N.)
| | | | - Mei Komoto
- Department of Adhesive Dentistry, School of Life Dentistry at Tokyo, The Nippon Dental University, 1-9-20, Fujimi, Chiyoda-ku, Tokyo 102-8159, Japan (M.K.); (Y.N.)
| | - Yunqing Liu
- Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Sapporo 060-8586, Japan; (Y.L.); (Y.L.); (H.S.); (A.T.)
| | - Yoichiro Nara
- Department of Adhesive Dentistry, School of Life Dentistry at Tokyo, The Nippon Dental University, 1-9-20, Fujimi, Chiyoda-ku, Tokyo 102-8159, Japan (M.K.); (Y.N.)
| | - Hidehiko Sano
- Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Sapporo 060-8586, Japan; (Y.L.); (Y.L.); (H.S.); (A.T.)
| | - Pedro Alvarez-Lloret
- Department of Geology, Faculty of Geology, University of Oviedo, Campus de Llamaquique, s/n, 33005 Oviedo, Spain;
- Department of Mineralogy and Petrology, Faculty of Sciences, University of Granada, Av. Fuente Nueva, s/n, 18071 Granada, Spain
| | - Monica Yamauti
- Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Sapporo 060-8586, Japan; (Y.L.); (Y.L.); (H.S.); (A.T.)
| | - Atsushi Tomokiyo
- Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Sapporo 060-8586, Japan; (Y.L.); (Y.L.); (H.S.); (A.T.)
| |
Collapse
|
3
|
Campos RP, Mailart MC, Matuda AGN, Yui KCK, Chagas GDS, Rocha MB, Tay FR, Pucci CR. Effect of Nisin-based pretreatment solution on dentin bond strength, antibacterial property, and MMP activity of the adhesive interface. J Mech Behav Biomed Mater 2024; 152:106407. [PMID: 38277911 DOI: 10.1016/j.jmbbm.2024.106407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 01/11/2024] [Accepted: 01/15/2024] [Indexed: 01/28/2024]
Abstract
OBJECTIVE To evaluate the effect of a Nisin-based dentin pretreatment solution on microtensile bond strength, antibacterial activity, and matrix metalloproteinase (MMP) activity of the adhesive interface. MATERIALS AND METHODS 100 human molars were sectioned to expose dentin. The teeth were assigned to five groups (n = 20), according to the dentin pretreatment: 0.5%, 1.0%, or 1.5% Nisin; 0.12% chlorhexidine (positive control), and no solution (negative control), and divided into 2 subgroups: no aging, and thermomechanical aging. Specimens were etched with 37% H3PO4 for 15 s and submitted to the dentin pretreatment. Then, they were bonded with an adhesive (Adper Single Bond 2) and a resin composite for microtensile bond strength (μTBS) evaluation. Antibacterial activity against Streptococcus mutans was qualitatively examined using an agar diffusion test. Anti-MMP activity within hybrid layers was examined using in-situ zymography. Data were analyzed with two-factor ANOVA and post-hoc Tukey's test (α = 0.050). RESULTS For μTBS, significant differences were identified for the factors "solutions" (p = 0.002), "aging" (p = 0.017), and interaction of the two factors (p = 0.002). In the absence of aging, higher μTBS was observed for the group 0.5% Nisin. In the presence of aging, all groups showed similar μTBS values. All Nisin concentrations were effective in inhibiting the growth of S. mutans. Endogenous MMP activity was more significantly inhibited using 0.5% and 1.0% Nisin (p < 0.050). CONCLUSION 0.5% and 1.0% Nisin solutions do not adversely affect resin-dentin bond strength and exhibit a potential bactericidal effect against S. mutans. Both concentrations effectively reduce endogenous gelatinolytic activity within the hybrid layer. CLINICAL RELEVANCE The use of 0.5% and 1.0% Nisin solutions for dentin pretreatment potentially contributes to preserving the adhesive interface, increasing the longevity of composite restorations.
Collapse
Affiliation(s)
- Raquel Pinto Campos
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University, Sao José dos Campos, SP, Brazil
| | - Mariane Cintra Mailart
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University, Sao José dos Campos, SP, Brazil.
| | - Amanda Guedes Nogueira Matuda
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University, Sao José dos Campos, SP, Brazil
| | - Karen Cristina Kazue Yui
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University, Sao José dos Campos, SP, Brazil
| | - Gabriela da Silva Chagas
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University, Sao José dos Campos, SP, Brazil
| | - Marcella Batista Rocha
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University, Sao José dos Campos, SP, Brazil
| | - Franklin R Tay
- Department of Endodontics, The Dental College of Georgia, Augusta University, Augusta, USA
| | - Cesar Rogerio Pucci
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University, Sao José dos Campos, SP, Brazil
| |
Collapse
|
4
|
Sun G, Chen H, Wang H, Chen X, Wei F, Bai T, Zhu S. Effects of Nd:YAG laser irradiation at different energy densities on dentin bond durability under simulated pulpal pressure. Clin Oral Investig 2024; 28:202. [PMID: 38453707 DOI: 10.1007/s00784-024-05600-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Accepted: 03/04/2024] [Indexed: 03/09/2024]
Abstract
OBJECTIVES To evaluate the effects of Nd:YAG laser irradiation on the microstructures of dentin surfaces and the long-term bond strength of dentin under simulated pulpal pressure. MATERIALS AND METHODS Under simulated pulp pressure, 30 freshly extracted caries-free third molars were cut into 2-mm-thick dentin samples and then divided into five groups: the control and laser groups (93.3 J/cm2; 124.4 J/cm2; 155.5 J/cm2; 186.6 J/cm2). Scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), and Vickers hardness were used to analyze the surface morphology, composition, and mechanical properties of the dentin before and after laser irradiation. Another 80 caries-free third molars were removed and treated as described above, and the resin was bonded to the dentin surface with Single Bond Universal (SBU) adhesive in self-etch mode to make stick specimens. Microtensile bond strength (µTBS), confocal laser scanning microscopy (CLSM), and interfacial silver nanoleakage tests before and after 10,000 times thermocycling were then performed to analyze the bonding properties and interfacial durability of each group. RESULTS SEM observations revealed that the surfaces of all laser group specimens were rough with open dentin tubules. Laser irradiation altered the surface composition of dentin while removing some collagen fibers but did not affect its surface hardness or crystallographic characteristics. Furthermore, laser irradiation with an energy density of 124.4 J/cm2 significantly promoted the immediate and aging bond strengths and reduced nanoleakage compared to those of the control group. CONCLUSIONS Under simulated pulp pressure, Nd:YAG laser pretreatment altered the chemical composition of dentin and improved the immediate and long-term bond strength. CLINICAL RELEVANCE This study investigated the optimal parameters for Nd:YAG laser pretreatment of dentin, which has potential as a clinical method to strengthen bonding.
Collapse
Affiliation(s)
- Guangdi Sun
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, 1500 Qinghua Road, Chaoyang District, Changchun, Jilin, 130012, China
| | - Huan Chen
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, 1500 Qinghua Road, Chaoyang District, Changchun, Jilin, 130012, China
| | - Huimin Wang
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, 1500 Qinghua Road, Chaoyang District, Changchun, Jilin, 130012, China
| | - Xue Chen
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, 1500 Qinghua Road, Chaoyang District, Changchun, Jilin, 130012, China
| | - Fei Wei
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, 1500 Qinghua Road, Chaoyang District, Changchun, Jilin, 130012, China
| | - Tingting Bai
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, 1500 Qinghua Road, Chaoyang District, Changchun, Jilin, 130012, China
| | - Song Zhu
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, 1500 Qinghua Road, Chaoyang District, Changchun, Jilin, 130012, China.
| |
Collapse
|
5
|
Perote LCCC, Barcellos DC, Matuda AGN, Campos RP, Rosetti EP, Pucci CR. Influence of chlorhexidine, propolis, pulpal pressure simulation, and aging on dentin bond strength. Microsc Res Tech 2022; 85:3014-3024. [PMID: 35593488 DOI: 10.1002/jemt.24150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 03/09/2022] [Accepted: 05/01/2022] [Indexed: 11/05/2022]
Abstract
The present study evaluated the bond strength (μTBS) of dentin treated with chlorhexidine and propolis subjected to simulated pulpal pressure (SPP) and thermocycle aging. One hundred and twenty healthy human molars were sectioned to obtain 2 mm of dentin thickness and were divided into two groups (n = 60): SPP (15 cm H2 O) and no SPP (Control group). Dentin surfaces were conditioned with 37% phosphoric acid for 15 s and were divided according to the dentin treatment (n = 20): Control; Chlorhexidine gluconate (0.2% for 30 s) and Propolis (aqueous propolis extract for 30 s). Half of the specimens were submitted to 15,000 thermocycle aging (5 ± 2°C and 55 ± 2°C). The samples were sectioned into beams and submitted to μTBS. Data were analyzed by three-way ANOVA (SPP × Dentin treatment × Thermocycle aging) and the Tukey's tests (p < .001). With regard to the SPP, ANOVA revealed that the Control group (32.98 MPa) had significantly higher values of μTBS when compared to the SPP (29.19 MPa). With regard to Thermocycle aging, no aging (34.05 MPa) had significantly higher values of μTBS when compared to the aging (28.12 MPa). With regard to the dentin treatment, Propolis and Chlorhexidine did not statistically influence the results (p > .05). The SPP and thermocycle aging negatively influenced the bond strength between the dentin and resin; the 0.2% chlorhexidine digluconate and aqueous propolis extract solutions did not interfere in the bond strength between the resin and dentin. The use of chlorhexidine and propolis as a dental treatment may not influence the dentin bond strength, but SPP and thermocycle aging may damage the longitudinal dentin bond strength.
Collapse
Affiliation(s)
| | | | - Amanda Guedes Nogueira Matuda
- Department Restorative Dentistry, Institute of Science and technology, UNESP - Univ Estadual Paulista, São José dos Campos, SP, Brazil
| | - Raquel Pinto Campos
- Department Restorative Dentistry, Institute of Science and technology, UNESP - Univ Estadual Paulista, São José dos Campos, SP, Brazil
| | | | - César Rogério Pucci
- Department Restorative Dentistry, Institute of Science and technology, UNESP - Univ Estadual Paulista, São José dos Campos, SP, Brazil
| |
Collapse
|
6
|
Hass V, Cartagena AF, Matos TP, de Souza JJ, Toyotani PE, Reis A, Calixto AL, Loguercio AD. Sonic application of one-step self-etch adhesive in composite restorations of non-carious cervical lesions: A double-blind randomized clinical trial. J ESTHET RESTOR DENT 2022; 34:689-698. [PMID: 35138027 DOI: 10.1111/jerd.12885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 01/17/2022] [Accepted: 01/19/2022] [Indexed: 11/28/2022]
Abstract
OBJECTIVES To evaluate the influence of the sonic device on the clinical performance of one-step self-etch adhesive systems in non-carious cervical lesions (NCCLs) after 18 months. MATERIALS AND METHODS Forty patients participated in this study. Eighty restorations were assigned to two groups (n = 40): Sonic application and Manual application. After the adhesive application (iBond Self-Etch, Kulzer, Hanau, Germany), NCCLs were restored using composite resin (Charisma, Kulzer, Hanau, Germany). The restorations were evaluated at baseline and after 18 months both according to the Word Dental Federation (FDI) and the United States Public Health Service (USPHS) criteria. Friedman repeated measures analysis of variance by rank and Wilcoxon test for significance in each pair were applied (α = 0.05). RESULTS After 18 months, 38 patients were evaluated. Twenty-three restorations were lost (19 for manual vs. 4 for sonic application). The retention rates (95% confidence interval) were 50% (CI 34.8%-65.1%) for manual application and 84.2% (CI 69.6%-92.6%) for sonic application (p < 0.05). Twelve restorations showed marginal staining (nine for manual vs. three for sonic application; FDI, p < 0.05) and nine some marginal discrepancy (seven for manual vs. two for sonic application; FDI, p < 0.05). No restorations showed postoperative sensitivity and caries recurrence at the time. CONCLUSION The sonic application increases the retention rate of iBond Self-Etch after 18 months of clinical evaluation in NCCLs. CLINICAL RELEVANCE The application of a simplified self-etch adhesive (iBond Self-Etch) associated to a sonic device seems to be an alternative to improve the clinical behavior in NCCLs.
Collapse
Affiliation(s)
- Viviane Hass
- Postograduate Program in Dentistry, University of Northern Parana, Londrina, Brazil.,School of Dentistry, University of Missouri - Kansas City, USA
| | - Andres F Cartagena
- Faculdad de Odontología Mexicali, Universidade Autônoma de Baja California, Mexicali, Mexico
| | | | - Jullian J de Souza
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
| | - Patricia E Toyotani
- Postograduate Program in Dentistry, University of Northern Parana, Londrina, Brazil
| | - Alessandra Reis
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
| | - Abraham L Calixto
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
| | - Alessandro D Loguercio
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
| |
Collapse
|
7
|
Fehrenbach J, Isolan CP, Münchow EA. Is the presence of 10-MDP associated to higher bonding performance for self-etching adhesive systems? A meta-analysis of in vitro studies. Dent Mater 2021; 37:1463-1485. [PMID: 34456050 DOI: 10.1016/j.dental.2021.08.014] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 08/16/2021] [Accepted: 08/17/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The purpose of this systematic review and meta-analysis was to analyze the literature on the bond strength of self-etching (SE) adhesives containing 10-MDP or other acidic functional monomers, comparing the bonding performance of both compositions. METHODS This study is registered in PROSPERO (CRD42020175715) and it followed the PRISMA Statement. The literature search was performed in PubMed, Web of Science, SciELO, Scopus, LILACS, IBECS, and BBO from the starting coverage date through 30 June 2021. Study eligibility criteria consisted of in vitro studies that evaluated the bond strength (microtensile, microshear, tensile or shear testing) to sound dentin/enamel of a minimum of two distinct SE systems, with at least one material containing 10-MDP and one other being comprised of a distinct acidic composition. Statistical analyses were carried out with RevMan 5.3.5 and using random-effects models with the significance level at p < 0.05. Also, Bayesian network meta-analysis (NMA) was conducted using MetaInsight V3 tool. RESULTS From 740 relevant studies evaluated in full-text analysis, 210 were incorporated to the systematic review and 206 in meta-analysis. The majority of studies was classified as having medium risk of bias (56.7%), followed by low (35.2%) and high (8.1%) risk of bias. Data from a total of 64 adhesive systems were collected, which favored the 10-MDP-based group at both dentin (overall effect: 6.98; 95% CI: 5.61, 8.36; p < 0.00001) and enamel (overall effect: 2.79; 95% CI: 1.62, 3.96; p < 0.00001) substrates. Microtensile testing was more frequently used (73.4%) in the included studies. Adhesives based on 10-MDP showed greater bonding performance than adhesives comprised of monomers such as PENTA, 6-MHP, 4-META, 4-MET, pyrophosphate esters, mixed composition or monomers derived from sulfonic acid (p ≤ 0.01); whereas similar bond strength values were verified between 10-MDP-based materials and those containing PEM-F, acrylamide phosphates, 4-AET, MAC-10, or monomers derived from polyacrylic and phosphonic acids (p ≥ 0.05). Adhesives based on GPDM were the only ones that resulted in greater bonding potential than the 10-MDP-based group (p = 0.03). Dental bonds in dentin were favored with the application of 2-step 10-MDP-based adhesives; whereas in enamel the dental bonds were favored for both 2-steps versions of adhesives, regardless of the presence of 10-MDP. Indirect evidence from NMA revealed that 1-step 10-MDP-free and universal 10-MDP-free adhesives seemed to perform worst in dentin and enamel, respectively. SIGNIFICANCE Adhesives containing 10-MDP showed higher bonding performance than materials formulated with other acidic ingredients, although this result relied on the type of mechanical testing, type of the substrate, acidic composition of the adhesive, and the application category of the SE system. This review summarized the effects of the foregoing factors on the adhesion to dental substrates.
Collapse
Affiliation(s)
- Julia Fehrenbach
- Graduate Program in Dentistry, School of Dentistry, Federal University of Rio Grande do Sul, Rua Ramiro Barcelos, 2492, Santa Cecília, Porto Alegre, Brazil.
| | - Cristina Pereira Isolan
- Department of Restorative Dentistry, School of Dentistry, Federal University of Jequitinhonha and Mucuri Valleys, Rua da Glória, 187, Centro, Diamantina, Brazil.
| | - Eliseu Aldrighi Münchow
- Graduate Program in Dentistry, School of Dentistry, Federal University of Rio Grande do Sul, Rua Ramiro Barcelos, 2492, Santa Cecília, Porto Alegre, Brazil; Department of Conservative Dentistry, School of Dentistry, Federal University of Rio Grande do Sul, Rua Ramiro Barcelos, 2492, Porto Alegre, Brazil.
| |
Collapse
|
8
|
Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin. Odontology 2021; 110:62-69. [PMID: 34213683 DOI: 10.1007/s10266-021-00633-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 06/24/2021] [Indexed: 10/20/2022]
Abstract
The aim of this study was to evaluate the effect of SPP with either fetal bovine serum (FBS) or deionized water (DW) on the bond strength (μTBS) of a Universal adhesive to dentin, in both etch-and-rinse (ER) and self-etch (SE) modes. The kinematic viscosity (cSt) of FBS and DW was measured at 25 °C ± 0.1 ºC. Seventy-two sound human molars were sectioned and randomly divided into three groups according to the SPP conditions: (1) Control (0 cm H2O), (2) SPP (15 cm H2O) with FBS, (3) SPP (15 cm H2O) with DW. Each group was subdivided (n = 10) based on the bonding modes: ER (37% phosphoric acid + ScothBond Universal Adhesive) or SE (ScothBond Universal Adhesive). Samples were then submitted to μTBS. Data were analyzed by Student's t test, two-way ANOVA and Tukey tests (p < 0.05). The cSt results showed that DW (23.59 ± 0.39) had significantly higher values than FBS (22.33 ± 0.06). With regard to SPP, the control group (36.1 MPa) had significantly higher values of μTBS when compared to the SPP using FBS (31.06 MPa) and SPP with DW (26.55 MPa). According to ANOVA, the bonding modes and the interaction of simulated pulpal pressure (SPP) did not statistically influence the results (p < 0.05). The presence of SPP reduced the bond strength of Universal adhesive to dentin. DW during SPP had significantly reduced bonding values when compared to FBS. Bonding strategies were not affected by SPP when evaluated in a short period of time (24 h).
Collapse
|
9
|
de Menezes LR, da Silva EO, Maurat da Rocha LV, Ferreira Barbosa I, Rodrigues Tavares M. The use of clays for chlorhexidine controlled release as a new perspective for longer durability of dentin adhesion. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2019; 30:132. [PMID: 31786679 DOI: 10.1007/s10856-019-6344-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2019] [Accepted: 11/16/2019] [Indexed: 06/10/2023]
Abstract
The adhesive systems have the function to establish the connection between the restorative material and dental tissue, therefore it is of fundamental importance, because failures in the adhesive interface can reduce the life of a dental restoration. This study investigated the possibility of using the adhesive layer as a chlorhexidine modified release system evaluating their impact on the properties of these systems as well as evaluating the impact of these systems on immediate and post-aging dentin adhesion. Were used a matrix with BisGMA, UDMA, HEMA and TEGDMA copolymer and clay particles (Dellite 67G); associated with a chlorhexidine and a camphorquinone photoinitiator system. The properties of these systems were evaluated by the XRD, FTIR spectrophotometer, flexural strength, elasticity modulus, drug release, enzymatic inhibition and dentin adhesion resistance. The presence of the clay can raise the mechanical properties of the adhesive systems engendering a more resistant hybrid layer and led to a more sustained release of chlorhexidine in the systems, allowing a longer effective period of MMP-2 inhibition. The hypothesis that the addition of clays as release modulators could increase the effectiveness of these drugs in inhibiting the dentin's MPPs and consequently enhancing the adhesive durability was confirmed. These results indicate that the controlled release of chlorhexidine is able to reduce the process of loss of adhesion presenting itself as a promising system to increase the longevity of dental restorations.
Collapse
Affiliation(s)
- Lívia Rodrigues de Menezes
- Instituto de Macromoléculas Professora Eloisa Mano da Universidade Federal do Rio de Janeiro UFRJ, Rio de Janeiro, Brazil.
| | - Emerson Oliveira da Silva
- Instituto de Macromoléculas Professora Eloisa Mano da Universidade Federal do Rio de Janeiro UFRJ, Rio de Janeiro, Brazil
| | - Lizandra Viana Maurat da Rocha
- Instituto de Macromoléculas Professora Eloisa Mano da Universidade Federal do Rio de Janeiro UFRJ, Rio de Janeiro, Brazil
| | - Isabel Ferreira Barbosa
- Faculdade de Odontologia de Piracicaba/Universidade Estadual de Campinas UNICAMP, Campinas, Brazil
| | | |
Collapse
|
10
|
Adhesive Systems Used in Indirect Restorations Cementation: Review of the Literature. Dent J (Basel) 2019; 7:dj7030071. [PMID: 31266163 PMCID: PMC6784471 DOI: 10.3390/dj7030071] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 05/22/2019] [Accepted: 06/12/2019] [Indexed: 11/22/2022] Open
Abstract
New technologies are changing the therapeutical options to do indirect restorations and new adhesive systems are continuously introduced to be used by clinicians. Different interactions between restorations, adhesive systems components, enamel and dentin require having criteria based on the selection of the adhesive system, ensuring the longevity of the restorations and the preservation of the biological remnant. The adhesion force to the dental tissue is one of the indicatives of the behavior of the adhesive systems and influences the behavior of the treatments with direct and indirect restorations. The objective of this search was to find the adhesive systems with the best results in terms of the adhesion strength of indirect restorations on the dental tissues. The search was conducted in two MEDLINE digital databases (PubMed), and the Cochrane Library with a search strategy based on the combination of MeSH (Medical Subject Headings) keywords. This systematic review used the PRISMA guide (Preferred Reporting Items for Systematic Reviews and Meta-Analysis). According to this review, the 3-step adhesive systems were the best performing and still are the gold standard for the cementing of indirect restorations. In addition, it can be concluded that self-etched adhesive systems reduce the time spent in clinical practice, however at the interface level they behave as permeable membranes more susceptible to degradation.
Collapse
|
11
|
El Mourad AM. Assessment of Bonding Effectiveness of Adhesive Materials to Tooth Structure using Bond Strength Test Methods: A Review of Literature. Open Dent J 2018; 12:664-678. [PMID: 30369976 PMCID: PMC6182887 DOI: 10.2174/1745017901814010664] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Revised: 07/30/2018] [Accepted: 09/03/2018] [Indexed: 12/13/2022] Open
Abstract
Background The rapid developments in the field of adhesive dental materials have led to improvements in many aspects of clinical dentistry. Adhesive bond strength plays an important role in determining the clinical performance and longevity of dental restorations. Nevertheless, bond strength tests have never been well-standardized, although a number of important recommendations have been made. Objective The aim of this paper is to critically review the validity of different bond strength testing methods for assessment of bonding effectiveness of adhesive materials to tooth structure and discuss factors that may affect bond strength measurement. Data Collection Relevant literature published between 1983 and 2018 was collected and reviewed from the PubMed database and Google scholar resources. Review Results Results of the current bond testing methods should be used to compare materials tested under the same laboratory settings, but they shouldn't be used to make direct inferences on their clinical behaviour. Shear and micro-shear tests, result in non-uniform stress distribution, stress concentration at the substrate area, and predominantly tensile stresses rather than shear stresses. Micro-tensile bond tests provide many advantages over the shear tests, although these methods are technique sensitive and labour intensive. Conclusion Bond strength testing methods should be well-standardized, but there are many factors that cannot be fully controlled which leads to variation and misinterpretation of the data about the bonding abilities of adhesives. Clinical Significance New adhesive materials should be subjected to a combination of testing protocols to properly assess their bonding effectiveness.
Collapse
Affiliation(s)
- Aminah M El Mourad
- Department of Restorative Dental Sciences, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|