1
|
Zhang Y, Luo J, Di P, Chen B, Li J, Yu Z, Lin Y. Screw-retained ceramic-veneered/monolithic zirconia partial implant-supported fixed dental prostheses: A 5 to 10-year retrospective study on survival and complications. J Prosthodont 2024; 33:221-230. [PMID: 37302066 DOI: 10.1111/jopr.13723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2023] [Accepted: 06/02/2023] [Indexed: 06/12/2023] Open
Abstract
PURPOSE To assess the clinical performance of screw-retained, ceramic-veneered, monolithic zirconia partial implant-supported fixed dental prostheses (ISFDP) over 5-10 years and to evaluate implant- and prosthesis-related factors influencing treatment failure and complications. MATERIALS AND METHODS Partially edentulous patients treated with screw-retained all-ceramic ISFDPs with 2-4 prosthetic units with a documented follow-up of ≥5 years after implant loading were included in this retrospective study. The outcomes analyzed included implant/prosthesis failure and biological/technical complications. Possible risk factors were identified using the mixed effects Cox regression analysis. RESULTS A screened sample of 171 participants with 208 prostheses (95% of the restorations were splinted crowns without a pontic) supported by 451 dental implants were enrolled in this study. The mean follow-up duration after prosthesis delivery was 82.4 ±17.2 months. By the end of the follow-up period, 431 (95.57%) of the 451 implants remained functional at the implant level. At the prosthesis level, 185 (88.94%) of the 208 partial ISFDPs remained functional. Biological complications were observed in 67 implants (14.86%), and technical complications were observed in 62 ISFDPs (29.81%). Analysis revealed only emergence profiles (over-contoured) as a significant risk factor for implant failure (P<0.001) and biological complications (P<0.001). Full-coverage ceramic-veneered zirconia prostheses had a significantly greater chance of chipping (P<0.001) compared with buccal-ceramic-veneered or monolithic zirconia prostheses. CONCLUSIONS Screw-retained ceramic-veneered, monolithic partial ISFDPs have a favorable long-term survival rate. Over-contoured emergence profile is a significant risk factor associated with implant failure and biological complications. Buccal-ceramic-veneered and monolithic zirconia partial ISFDPs lower the initial prevalence of chipping compared with a full-coverage veneered design.
Collapse
Affiliation(s)
- Yifan Zhang
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Disease & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing, PR China
| | - Jia Luo
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Disease & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing, PR China
| | - Ping Di
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Disease & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing, PR China
| | - Bo Chen
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Disease & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing, PR China
| | - Jianhui Li
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Disease & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing, PR China
| | - Ziyang Yu
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Disease & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing, PR China
| | - Ye Lin
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Disease & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing, PR China
| |
Collapse
|
2
|
Castillo-Oyagüe R, Río JD, Preciado A, Lynch CD, García-Minguillán G. 'Role of the modulating factors on the self-perceived OHRQoL of fully dentate subjects and wearers of screw-retained and cement-retained implant-supported FPDs: A cross-sectional study'. J Dent 2021; 117:103887. [PMID: 34762987 DOI: 10.1016/j.jdent.2021.103887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Revised: 10/07/2021] [Accepted: 10/11/2021] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVES This research aimed to compare the oral health-related quality of life (OHRQoL) between fully dentate subjects and edentulous patients wearing implant-supported fixed partial dentures (i-FPDs). The clinical conditions of both types of restorations were evaluated. METHODS Participants were assigned to: Group-1 (SR, n= 50): screw-retained i-FPD wearers; Group-2 (CR, n= 50): cement-retained i-FPD wearers; and Group-3 (ND, n= 50): dentate subjects with a healthy natural dentition (controls). Patients answered the OHIP-14sp and QoLIP-10 questionnaires. Data related to sociodemographics, prosthesis features, peri-implant status, complications, and subjective evaluations, were compiled. Potential modulators of the OHRQoL and the i-FPDs' clinical conditions were assessed using non-parametric tests (α= 0.05). RESULTS ND individuals were the least satisfied (OHIP-14sp; p< 0.001). Both prosthodontic groups reported similar levels of wellbeing, excluding the speaking difficulties, which were lower for SR wearers as shown by both scales (p= 0.001). The most discontented patients (OHIP-14sp) were: women (p= 0.022), under 65 years (p= 0.03), without partner (p< 0.001) and having a crown (p= 0.033). The level of education/schooling also affected the OHIP-14sp scores (p< 0.001). Implant mobility and peri-implantitis were more frequent among CR wearers (p-values= 0.008 and 0.05, respectively). CONCLUSIONS The OHRQoL of both prosthodontic groups was comparably higher than that of the dentate subjects, who were the most nonconformist. The self-perceived satisfaction was mainly modulated by sociodemographic factors. CLINICAL SIGNIFICANCE Overall, the retention system did not impact the OHRQoL, prosthetic problems, and subjective evaluations of i-FPD wearers. However, the cementation may increase the risk of peri-implant diseases.
Collapse
Affiliation(s)
- Raquel Castillo-Oyagüe
- Professor. Faculty of Dentistry, Complutense University of Madrid (U.C.M.), Madrid, Spain.
| | - Jaime Del Río
- Cathedratic Professor. Faculty of Dentistry, Complutense University of Madrid (U.C.M.), Madrid, Spain
| | - Arelis Preciado
- Researcher. Faculty of Dentistry, Complutense University of Madrid (U.C.M.), Madrid, Spain
| | - Christopher D Lynch
- Professor & Consultant. University Dental School & Hospital/ University College Cork, Wilton, Cork, Ireland
| | | |
Collapse
|
3
|
García-Minguillán G, Preciado A, Romeo M, Río JD, Lynch CD, Castillo-Oyagüe R. 'Differences in self-perceived OHRQoL between fully dentate subjects and edentulous patients depending on their prosthesis type, socio-demographic profile, and clinical features'. J Dent 2021; 114:103756. [PMID: 34333055 DOI: 10.1016/j.jdent.2021.103756] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 06/25/2021] [Accepted: 07/01/2021] [Indexed: 10/20/2022] Open
Abstract
OBJECTIVES This observational cross-sectional study aimed to evaluate and compare the oral health-related quality of life (OHRQoL) and clinical performance between dentate subjects and edentulous patients restored with conventional dentures or implant overdentures. METHODS 85 edentulous patients were grouped as follows: Group-1 (CD): conventional denture wearers (n= 42), and Group-2 (IO): implant-retained overdenture wearers (n= 43). For the OHRQoL comparisons, a control group of subjects with a healthy natural dentition (Group-3, ND; n= 50) was included. Participants completed three validated questionnaires (OHIP-14sp, OHIP-20sp, and QoLIP-10). Socio-demographic data, prosthesis-related factors, clinical condition of the mouth, and patient subjective evaluations, were gathered. Descriptive and non-parametric probes were run (α= 0.05). RESULTS The ND group was the most unsatisfied (OHIP-14sp; p≤ 0.001). The OHIP-20sp attributed significantly worse Psychological disability (p= 0.029) and Handicap (p= 0.027) to CD wearers when compared to IO wearers. The CD group showed the significantly highest need for relining (p= 0.041), and the lowest retention (p= 0.011). The OHIP-14sp disclosed a significantly worse OHRQoL for those volunteers who had a job (p= 0.003), a basic education instead of a secondary one (p= 0.022), and no partner (p= 0.006). CONCLUSIONS The overall OHRQoL was comparable for both prosthodontic groups, being modulated by socio-demographic and prosthesis-related features. Nonetheless, CD wearers presented prosthetic complications more frequently.
Collapse
Affiliation(s)
| | - Arelis Preciado
- Faculty of Dentistry, Complutense University of Madrid (UCM), Pza. Ramón y Cajal s/n, 28040, Madrid, Spain.
| | - Marta Romeo
- Faculty of Dentistry, Complutense University of Madrid (UCM), Pza. Ramón y Cajal s/n, 28040, Madrid, Spain.
| | - Jaime Del Río
- Faculty of Dentistry, Complutense University of Madrid (UCM), Pza. Ramón y Cajal s/n, 28040, Madrid, Spain.
| | - Christopher D Lynch
- University Dental School & Hospital/ University College Cork, T12 E8YV, Wilton, Cork, Ireland.
| | - Raquel Castillo-Oyagüe
- Faculty of Dentistry, Complutense University of Madrid (UCM), Pza. Ramón y Cajal s/n, 28040, Madrid, Spain.
| |
Collapse
|
4
|
Villias AA, Kourtis SG, Karkazis HC, Polyzois GL. In vitro validation of Digital Image Analysis Sequence (DIAS) for the assessment of the marginal fit of cement-retained implant-supported experimental crowns. Int J Implant Dent 2021; 7:12. [PMID: 33585971 PMCID: PMC7882652 DOI: 10.1186/s40729-021-00290-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Accepted: 01/20/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The replica technique with its modifications (negative replica) has been used for the assessment of marginal fit (MF). However, identification of the boundaries between prosthesis, cement, and abutment is challenging. The recently developed Digital Image Analysis Sequence (DIAS) addresses this limitation. Although DIAS is applicable, its reliability has not yet been proven. The purpose of this study was to verify the DIAS as an acceptable method for the quantitative assessment of MF at cemented crowns, by conducting statistical tests of agreement between different examiners. METHODS One hundred fifty-one implant-supported experimental crowns were cemented. Equal negative replicas were produced from the assemblies. Each replica was sectioned in six parts, which were photographed under an optical microscope. From the 906 standardized digital photomicrographs (0.65 μm/pixel), 130 were randomly selected for analysis. DIAS included tracing the profile of the crown and the abutment and marking the margin definition points before cementation. Next, the traced and marked outlines were superimposed on each digital image, highlighting the components' boundaries and enabling MF measurements. One researcher ran the analysis twice and three others once, independently. Five groups of 130 measurements were formed. Intra- and interobserver reliability was evaluated with intraclass correlation coefficient (ICC). Agreement was estimated with the standard error of measurement (SEM), the smallest detectable change at the 95% confidence level (SDC95%), and the Bland and Altman method of limits of agreement (LoA). RESULTS Measured MF ranged between 22.83 and 286.58 pixels. Both the intra- and interobserver reliability were excellent, ICC = 1 at 95% confidence level. The intra- and interobserver SEM and SDC95% were less than 1 and 3 pixels, respectively. The Bland-Altman analysis presented graphically high level of agreement between the mean measurement of the first observer and each of the three other observers' measurements. Differences between observers were normally distributed. In all three cases, the mean difference was less than 1 pixel and within ± 3 pixels LoA laid at least 95% of differences. T tests of the differences did not reveal any fixed bias (P > .05, not significant). CONCLUSION The DIAS is an objective and reliable method able to detect and quantify MF at ranges observed in clinical practice.
Collapse
Affiliation(s)
- Aristeidis A Villias
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece. .,, 57-59 Kolokotroni Str., Piraeus, Greece.
| | - Stefanos G Kourtis
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Hercules C Karkazis
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Gregory L Polyzois
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| |
Collapse
|
5
|
Zhou H, Jiao Y, Ma CF, Wang C, Zhao SJ, Tian M, Tay FR, Chen JH. Clinical outcomes of implant-retained mandibular overdentures using the bar and magnetic attachment systems: an up to 5-year retrospective study. ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:1360. [PMID: 33313105 PMCID: PMC7723526 DOI: 10.21037/atm-20-2531] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background Implant-retained mandibular overdentures (IODs) represent an effective and reliable treatment modality for edentulous patients. The present retrospective study compared the clinical outcomes of IODs using bar attachment (BA) system with those using magnetic attachment (MA) system after functioning for up to 5 years. Methods Human subjects treated with IODs between 01-01-2010 and 12-31-2014 were identified from patient records. Of the 54 subjects who met the inclusion criteria, 48 subjects including 26 treated with BA-IODs and 22 with MA-IODs (96 mandibular implants) were recruited for the study. The implant units and prostheses were evaluated individually for peri-implant health. Prosthetic complications and maintenance during follow-up were recorded. The subjects responded to the visual analog scale (VAS) and the Oral Health Impact Profile questionnaires for evaluation of patient satisfaction and oral health-related quality of life (OHRQoL). Results The survival rates of the implants and prostheses were 96.9% and 95.8%, respectively, over a mean observation period of 48±11.3 (range, 13-64) months. Peri-implant probing depth (PPD) and plaque index (PI) were significantly better for the MA group compared with the BA group (P<0.05), while marginal bone loss (MBL) and sulcus bleeding index (SBI) showed no significant differences (P>0.05). Prosthetic complications and maintenance were attachment-dependent. Most recruited subjects were satisfied with their prostheses. There was no statistically significant difference regarding general patient satisfaction or OHRQoL between the two groups (P>0.05). Nevertheless, patients complained that the BA-IODs were significantly more difficult to clean than the MA-IODs (P<0.05). Conclusions IODs have an ideal medium-term outcome irrespective of the attachment design. It is recommended that oral hygiene instructions and regular clinical examination be given to subjects wearing IODs.
Collapse
Affiliation(s)
- Huan Zhou
- National Clinical Research Center for Oral Diseases, State Key Laboratory of Military Stomatology, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University, Xi'an, China
| | - Yang Jiao
- Department of Stomatology, the 7 Medical Center, Chinese PLA General Hospital, Beijing, China.,Outpatient Department of PLA Macao Garrison, Macao, China
| | - Chu-Fan Ma
- National Clinical Research Center for Oral Diseases, State Key Laboratory of Military Stomatology, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University, Xi'an, China
| | - Chao Wang
- Department of Stomatology, the 7 Medical Center, Chinese PLA General Hospital, Beijing, China
| | - San-Jun Zhao
- National Clinical Research Center for Oral Diseases, State Key Laboratory of Military Stomatology, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University, Xi'an, China
| | - Min Tian
- National Clinical Research Center for Oral Diseases, State Key Laboratory of Military Stomatology, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University, Xi'an, China
| | - Franklin R Tay
- Department of Endodontics, the Dental College of Georgia, Augusta University, Augusta, GA, USA
| | - Ji-Hua Chen
- National Clinical Research Center for Oral Diseases, State Key Laboratory of Military Stomatology, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University, Xi'an, China
| |
Collapse
|