1
|
Skaanvik SA, Stephens LI, Gateman SM, Geissler M, Mauzeroll J. Quantitative Feedback Referencing for Improved Kinetic Fitting of Scanning Electrochemical Microscopy Measurements. Anal Chem 2022; 94:13852-13859. [PMID: 36166706 DOI: 10.1021/acs.analchem.2c02498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Scanning electrochemical microscopy (SECM) has matured as a technique for studying local electrochemical processes. The feedback mode is most commonly used for extracting quantitative kinetic information. However, approaching individual regions of interest, as is commonly done, does not take full advantage of the spatial resolution that SECM has to offer. Moreover, fitting of experimental approach curves remains highly subjective due to the manner of estimating the tip-to-substrate distance. We address these issues using negative or positive feedback currents as a reference to calculate the tip-to-substrate distance directly for quantitative kinetic fitting of approach curves and line profiles. The method was first evaluated by fitting simulated data and then tested experimentally by resolving negative feedback and intermediate kinetics behavior in a spatially controlled fashion using (i) a flat, binary substrate composed of Au and SiO2 segments and (ii) a dual-mediator system for live-cell measurements. The methodology developed herein, named quantitative feedback referencing (QFR), improves fitting accuracy, removes fitting subjectivity, and avoids substrate-microelectrode contact.
Collapse
Affiliation(s)
| | - Lisa Irene Stephens
- Department of Chemistry, McGill University, Montreal, Quebec H3A 0B8, Canada
| | | | - Matthias Geissler
- Life Sciences Division, National Research Council of Canada, 75 de Mortagne Boulevard, Boucherville, Quebec J4B 6Y4, Canada
| | - Janine Mauzeroll
- Department of Chemistry, McGill University, Montreal, Quebec H3A 0B8, Canada
| |
Collapse
|
2
|
Enhanced electrochemiluminescence at silica nanochannel membrane studied by scanning electrochemical microscopy. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2021.115943] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
3
|
Paschoalino WJ, Payne NA, Pessanha TM, Gateman SM, Kubota LT, Mauzeroll J. Charge Storage in Graphene Oxide: Impact of the Cation on Ion Permeability and Interfacial Capacitance. Anal Chem 2020; 92:10300-10307. [DOI: 10.1021/acs.analchem.0c00218] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Waldemir J. Paschoalino
- Department of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal H3A 0B8, Quebec, Canada
- Department of Analytical Chemistry, Institute of Chemistry, University of Campinas, P.O. Box 6154, 13084-971 Campinas, SP Brazil
| | - Nicholas A. Payne
- Department of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal H3A 0B8, Quebec, Canada
| | - Tatiana M. Pessanha
- Department of Analytical Chemistry, Institute of Chemistry, University of Campinas, P.O. Box 6154, 13084-971 Campinas, SP Brazil
| | - Samantha M. Gateman
- Department of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal H3A 0B8, Quebec, Canada
| | - Lauro T. Kubota
- Department of Analytical Chemistry, Institute of Chemistry, University of Campinas, P.O. Box 6154, 13084-971 Campinas, SP Brazil
| | - Janine Mauzeroll
- Department of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal H3A 0B8, Quebec, Canada
| |
Collapse
|
4
|
Zhou P, Yao L, Su B. Fabrication, Characterization, and Analytical Application of Silica Nanopore Array-Modified Platinum Electrode. ACS APPLIED MATERIALS & INTERFACES 2020; 12:4143-4149. [PMID: 31886640 DOI: 10.1021/acsami.9b20165] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
In this work, we report a new approach to fabricate the nanopore array electrode (NAE) by transferring silica nanochannel membrane (SNM) to the surface of Pt electrode (0.5 mm in diameter) sealed by glass capillary (designated as Pt-NAE for simplicity). The SNM is supported via the irreversible covalent-bond formation with the surrounding glass capillary treated by plasma, thus providing long-term stability to Pt-NAE. Meanwhile, this fabrication process does not require pregrafting or premodification of Pt electrode surface, providing well-defined active surface domains. Thanks to the small pore diameter (∼2.3 nm) and negatively charged channel walls, the SNM is permselective and thus the electrochemical behavior of Pt-NAE is dependent on both electrolyte concentration and charge state of redox molecules. The permeability of SNM was determined by the scanning electrochemical microscopy (SECM) approach curve measurements coupled with finite-element simulations from a quantitative viewpoint. The permeability of anionic Ru(CN)64- was varied from 150 to 10.3 μm s-1 as the electrolyte concentration decreased from 1.0 to 0.01 M, while there is no obvious change for cationic Ru(NH3)63+. Finally, the as-prepared Pt-NAE is able to continuously monitor dissolved oxygen for up to 2 h in a solution containing biofouling reagents, exhibiting an enhanced antifouling ability and therefore excellent current stability. We believe the NAE with unique mass transport properties can be extended further for other analytical applications.
Collapse
Affiliation(s)
- Ping Zhou
- Institute of Analytical Chemistry, Department of Chemistry , Zhejiang University , Hangzhou 310058 , China
| | - Lina Yao
- Institute of Analytical Chemistry, Department of Chemistry , Zhejiang University , Hangzhou 310058 , China
| | - Bin Su
- Institute of Analytical Chemistry, Department of Chemistry , Zhejiang University , Hangzhou 310058 , China
| |
Collapse
|
5
|
Payne NA, Dawkins JIG, Schougaard SB, Mauzeroll J. Effect of Substrate Permeability on Scanning Ion Conductance Microscopy: Uncertainty in Tip-Substrate Separation and Determination of Ionic Conductivity. Anal Chem 2019; 91:15718-15725. [PMID: 31741380 DOI: 10.1021/acs.analchem.9b03907] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Composite electrodes can significantly improve the performance of an electrochemical device by maximizing surface area and active material loading. Typically, additives such as carbon are used to improve conductivity and a polymer is used as a binder, leading to a heterogeneous surface film with thickness on the order of 10s of micrometers. For such composite electrodes, good ionic conduction within the film is critical to capitalize on the increased loading of active material and surface area. Ionic conductivity within a film can be tricky to measure directly, and homogenization models based on porosity are often used as a proxy. SICM has traditionally been a topography-mapping microscopy method for which we here outline a new function and demonstrate its capacity for measuring ion conductivity within a lithium-ion battery film.
Collapse
Affiliation(s)
- Nicholas A Payne
- Department of Chemistry , McGill University , 801 Sherbrooke Street West , Montreal , Quebec Canada
| | - Jeremy I G Dawkins
- Department of Chemistry , McGill University , 801 Sherbrooke Street West , Montreal , Quebec Canada
| | - Steen B Schougaard
- Département de Chimie and NanoQAM , Université du Québec à Montréal , Montréal , Quebec Canada
| | - Janine Mauzeroll
- Department of Chemistry , McGill University , 801 Sherbrooke Street West , Montreal , Quebec Canada
| |
Collapse
|
6
|
Schmidt I, Plettenberg I, Kimmich D, Ellis H, Witt J, Dosche C, Wittstock G. Spatially Resolved Analysis of Screen Printed Photoanodes of Dye-Sensitized Solar Cells by Scanning Electrochemical Microscopy. Electrochim Acta 2016. [DOI: 10.1016/j.electacta.2016.11.030] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
7
|
Gossage ZT, Simpson BH, Schorr NB, Rodríguez-López J. Soft Surfaces for Fast Characterization and Positioning of Scanning Electrochemical Microscopy Nanoelectrode Tips. Anal Chem 2016; 88:9897-9901. [DOI: 10.1021/acs.analchem.6b02213] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Zachary T. Gossage
- Department of Chemistry, University of Illinois at Urbana−Champaign, 58 Roger Adams Laboratory, 600 South
Matthews Avenue, Urbana, Illinois 61801, United States
| | - Burton H. Simpson
- Department of Chemistry, University of Illinois at Urbana−Champaign, 58 Roger Adams Laboratory, 600 South
Matthews Avenue, Urbana, Illinois 61801, United States
| | - Noah B. Schorr
- Department of Chemistry, University of Illinois at Urbana−Champaign, 58 Roger Adams Laboratory, 600 South
Matthews Avenue, Urbana, Illinois 61801, United States
| | - Joaquín Rodríguez-López
- Department of Chemistry, University of Illinois at Urbana−Champaign, 58 Roger Adams Laboratory, 600 South
Matthews Avenue, Urbana, Illinois 61801, United States
| |
Collapse
|
8
|
Abstract
Accelerated aging experiments of Nafion® 212 (N212) membranes were carried out. Characterization of degraded N212 membrane samples was performed by microscopy, spectroscopy and electrochemical methods.
Collapse
Affiliation(s)
- Wenqing Shi
- Department of Chemistry
- Indiana University
- Bloomington
- USA
| | - Lane A. Baker
- Department of Chemistry
- Indiana University
- Bloomington
- USA
| |
Collapse
|
9
|
|
10
|
Electrochemical approaches for the fabrication and/or characterization of pure and hybrid templated mesoporous oxide thin films: a review. Anal Bioanal Chem 2012; 405:1497-512. [DOI: 10.1007/s00216-012-6334-7] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2012] [Revised: 07/12/2012] [Accepted: 08/06/2012] [Indexed: 11/26/2022]
|
11
|
Tan C, Rodríguez-López J, Parks JJ, Ritzert NL, Ralph DC, Abruña HD. Reactivity of monolayer chemical vapor deposited graphene imperfections studied using scanning electrochemical microscopy. ACS NANO 2012; 6:3070-3079. [PMID: 22424270 DOI: 10.1021/nn204746n] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Imperfections that disrupt the sp(2) conjugation of graphene can alter its electrical, chemical, and mechanical properties. Here we report on the examination of monolayer chemical vapor deposited graphene imperfections using scanning electrochemical microscopy in the feedback mode. It was found that the sites with a large concentration of defects are approximately 1 order of magnitude more reactive, compared to more pristine graphene surfaces, toward electrochemical reactions. Furthermore, we successfully passivated the activity of graphene defects by carefully controlling the electropolymerization conditions of o-phenylenediamine. With further electropolymerization, a thin film of the polymer was formed, and it was found to be insulating in nature toward heterogeneous electron transfer processes. The use of spatially resolved scanning electrochemical microscopy for detecting the presence and the "healing" of defects on graphene provides a strategy for in situ characterization and control of this attractive surface, enabling optimization of its properties for application in electronics, sensing, and electrocatalysis.
Collapse
Affiliation(s)
- Cen Tan
- Department of Chemistry and Chemical Biology, Cornell University, Ithaca, New York 14853, United States
| | | | | | | | | | | |
Collapse
|
12
|
Lefrou C, Cornut R. Analytical expressions for quantitative scanning electrochemical microscopy (SECM). Chemphyschem 2010; 11:547-56. [PMID: 20058287 DOI: 10.1002/cphc.200900600] [Citation(s) in RCA: 100] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Scanning electrochemical microscopy (SECM), is a recent analytical technique in electrochemistry, which was developed in the 1990s and uses microelectrodes to probe various surfaces. Even with the well-known disc microelectrodes, the system geometry is not as simple as in regular electrochemistry. As a consequence even the simplest experiments, the so-called positive and negative feedback approach curves, cannot be described with exact analytical expressions. This review gathers all the analytical expressions available in the SECM literature in steady-state feedback experiments. Some of them are claimed as general expressions, other are presented as approximate. Their validity is discussed in the light of the current understanding and computer facilities.
Collapse
Affiliation(s)
- Christine Lefrou
- LEPMI, Laboratoire d'Electrochimie et Physicochimie des Matériaux et des Interfaces, UMR 5631 CNRS-Grenoble-INP-Université Joseph Fourier, 1130 rue de la piscine, BP 75, Domaine Universitaire, 38402 Saint Martin d'Hères Cedex, France.
| | | |
Collapse
|
13
|
Matrab T, Hauquier F, Combellas C, Kanoufi F. Scanning Electron Microscopy Investigation of Molecular Transport and Reactivity within Polymer Brushes. Chemphyschem 2010; 11:670-82. [DOI: 10.1002/cphc.200900766] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
14
|
Guillemin Y, Etienne M, Aubert E, Walcarius A. Electrogeneration of highly methylated mesoporous silica thin films with vertically-aligned mesochannels and electrochemical monitoring of mass transport issues. ACTA ACUST UNITED AC 2010. [DOI: 10.1039/c0jm00305k] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
15
|
Cornut R, Hapiot P, Lefrou C. Enzyme-mediator kinetics studies with SECM: Numerical results and procedures to determine kinetics constants. J Electroanal Chem (Lausanne) 2009. [DOI: 10.1016/j.jelechem.2009.06.002] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|