1
|
Al Nasser HA, Bissett MA, Dryfe RAW. The Modified Liquid‐Liquid Interface: The Effect of an Interfacial Layer of MoS
2
on Ion Transfer. ChemElectroChem 2021. [DOI: 10.1002/celc.202100820] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Hussain A. Al Nasser
- Department of Chemistry The University of Manchester Oxford Road Manchester U.K. M13 9PL
| | - Mark A. Bissett
- Department of Materials The University of Manchester Oxford Road Manchester U.K. M13 9PL
- Henry Royce Institute The University of Manchester Oxford Road Manchester U.K. M13 9PL
| | - Robert A. W. Dryfe
- Department of Chemistry The University of Manchester Oxford Road Manchester U.K. M13 9PL
- Henry Royce Institute The University of Manchester Oxford Road Manchester U.K. M13 9PL
| |
Collapse
|
2
|
Burgoyne ED, Molina-Osorio AF, Moshrefi R, Shanahan R, McGlacken GP, Stockmann TJ, Scanlon MD. Detection of Pseudomonas aeruginosa quorum sensing molecules at an electrified liquid|liquid micro-interface through facilitated proton transfer. Analyst 2021; 145:7000-7008. [PMID: 32869782 DOI: 10.1039/d0an01245a] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Miniaturization of electrochemical detection methods for point-of-care-devices is ideal for their integration and use within healthcare environments. Simultaneously, the prolific pathogenic bacteria Pseudomonas aeruginosa poses a serious health risk to patients with compromised immune systems. Recognizing these two factors, a proof-of-concept electrochemical method employing a micro-interface between water and oil (w/o) held at the tip of a pulled borosilicate glass capillary is presented. This method targets small molecules produced by P. aeruginosa colonies as signalling factors that control colony growth in a pseudo-multicellular process known as quorum sensing (QS). The QS molecules of interest are 4-hydroxy-2-heptylquinoline (HHQ) and 2-heptyl-3,4-dihydroxyquinoline (PQS, Pseudomonas quinolone signal). Hydrophobic HHQ and PQS molecules, dissolved in the oil phase, were observed electrochemically to facilitate proton transfer across the w/o interface. This interfacial complexation can be exploited as a facile electrochemical detection method for P. aeruginosa and is advantageous as it does not depend on the redox activity of HHQ/PQS. Interestingly, the limit-of-linearity is reached as [H+] ≈ [ligand]. Density functional theory calculations were performed to determine the proton affinities and gas-phase basicities of HHQ/PQS, as well as elucidate the likely site of stepwise protonation within each molecule.
Collapse
Affiliation(s)
- Edward D Burgoyne
- The Bernal Institute and Department of Chemical Sciences, School of Natural Sciences, University of Limerick (UL), Limerick V94 T9PX, Ireland.
| | | | | | | | | | | | | |
Collapse
|
3
|
Viada BN, Yudi LM, Arrigan DWM. Detection of perfluorooctane sulfonate by ion-transfer stripping voltammetry at an array of microinterfaces between two immiscible electrolyte solutions. Analyst 2020; 145:5776-5786. [PMID: 32672287 DOI: 10.1039/d0an00884b] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Per- and polyfluoroalkyl substances (PFAS) are a category of persistent environmental contaminants that have been linked to health issues in humans. In this work, we investigate the detection of perfluorooctanesulfonate (PFOS-), one such PFAS, by ion-transfer voltammetry at an array of microinterfaces between two immiscible electrolyte solutions (μITIES). Cyclic voltammetry, differential pulse voltammetry and differential pulse stripping voltammetry (DPSV) indicated the ion-transfer behaviour and detection of PFOS-, with the latter enabling detection at picomolar concentrations. Using a 5 min preconcentration time, during which PFOS- was preconcentrated into the organic phase of the μITIES array, a limit of detection (LOD) of 0.03 nM (0.015 μg L-1) in aqueous electrolyte was achieved. This performance is attributed to the enhanced mass transport (radial diffusion) to the μITIES that occurs during preconcentration. To investigate the potentiality for applications of this analytical approach to environmental samples, measurements in a range of water matrices were investigated. Drinking water, laboratory tap water and seawater matrices were assessed by spiking with PFOS- over the 0.1-1 nM range. A matrix effect was observed, with changes in sensitivity and LOD relative to those in pure aqueous electrolyte solutions. Such matrix effects need to be considered in designing applications of these PFOS- measurements to environmental samples. The results presented here indicate that DPSV at a μITIES array can form the basis for a fast and sensitive screening method for PFOS- contamination that is suited to portable and on-site applications.
Collapse
Affiliation(s)
- Benjamín N Viada
- Curtin Institute for Functional Molecules and Interfaces, School of Molecular and Life Sciences, Curtin University, GPO Box U1987, Perth, Western Australia 6845, Australia.
| | | | | |
Collapse
|
4
|
Suárez-Herrera MF, Scanlon MD. Quantitative Analysis of Redox-Inactive Ions by AC Voltammetry at a Polarized Interface between Two Immiscible Electrolyte Solutions. Anal Chem 2020; 92:10521-10530. [PMID: 32608226 DOI: 10.1021/acs.analchem.0c01340] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The interface between two immiscible electrolyte solutions (ITIES) is ideally suited to detect redox-inactive ions by their ion transfer. Such electroanalysis, based on the Nernst-Donnan equation, has been predominantly performed using amperometry, cyclic voltammetry, or differential pulse voltammetry. Here, we introduce a new electroanalytical method based on alternating-current (AC) voltammetry with inherent advantages over traditional approaches such as avoidance of positive feedback iR compensation, a major issue for liquid|liquid electrochemical cells containing resistive organic media and interfacial areas in the cm2 and mm2 range. A theoretical background outlining the generation of the analytical signal is provided and based on extracting the component that depends on the Warburg impedance from the total impedance. The quantitative detection of a series of model redox-inactive tetraalkylammonium cations is demonstrated, with evidence provided of the transient adsorption of these cations at the interface during the course of ion transfer. Since ion transfer is diffusion-limited, by changing the voltage excitation frequency during AC voltammetry, the intensity of the Faradaic response can be enhanced at low frequencies (1 Hz) or made to disappear completely at higher frequencies (99 Hz). The latter produces an AC voltammogram equivalent to a "blank" measurement in the absence of analyte and is ideal for background subtraction. Therefore, major opportunities exist for the sensitive detection of ionic analyte when a "blank" measurement in the absence of analyte is impossible. This approach is particularly useful to deconvolute signals related to reversible electrochemical reactions from those due to irreversible processes, which do not give AC signals.
Collapse
Affiliation(s)
- Marco F Suárez-Herrera
- Departamento De Química, Facultad De Ciencias, Universidad Nacional De Colombia, Cra 30 # 45-03, Edificio 451, Bogotá, Colombia
| | - Micheál D Scanlon
- The Bernal Institute and Department of Chemical Sciences, School of Natural Sciences, University of Limerick (UL), Limerick V94 T9PX, Ireland
| |
Collapse
|
5
|
Molina A, Laborda E, González J, Compton RG. Linear Sweep and Cyclic Voltammetries of Reversible Ion Transfer Processes at Macro- and Microcapillaries under Transient Regime. ELECTROANAL 2015. [DOI: 10.1002/elan.201400398] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
6
|
Herzog G. Recent developments in electrochemistry at the interface between two immiscible electrolyte solutions for ion sensing. Analyst 2015; 140:3888-96. [DOI: 10.1039/c5an00601e] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The most recent developments on electrochemical sensing of ions at the liquid–liquid interface are reviewed here.
Collapse
Affiliation(s)
- Grégoire Herzog
- Laboratoire de Chimie Physique et Microbiologie pour l'Environnement (LCPME)
- UMR 7564
- CNRS – Université de Lorraine
- Villers-lès-Nancy
- France
| |
Collapse
|
7
|
Lee SH, Sumranjit J, Tongkate P, Chung BH, Lee HJ. Voltammetric Studies of Cu(II) Ion Transfer Reaction with Picolinamide-phenylenevinylene across Liquid/liquid Interfaces and Their Sensing Applications. Electrochim Acta 2014. [DOI: 10.1016/j.electacta.2014.01.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
8
|
Abstract
Here we review the recent applications of ion transfer (IT) at the interface between two immiscible electrolyte solutions (ITIES) for electrochemical sensing and imaging. In particular, we focus on the development and recent applications of the nanopipet-supported ITIES and double-polymer-modified electrode, which enable the dynamic electrochemical measurements of IT at nanoscopic and macroscopic ITIES, respectively. High-quality IT voltammograms are obtainable using either technique to quantitatively assess the kinetics and dynamic mechanism of IT at the ITIES. Nanopipet-supported ITIES serves as an amperometric tip for scanning electrochemical microscopy to allow for unprecedentedly high-resolution electrochemical imaging. Voltammetric ion sensing at double-polymer-modified electrodes offers high sensitivity and unique multiple-ion selectivity. The promising future applications of these dynamic approaches for bioanalysis and electrochemical imaging are also discussed.
Collapse
|
9
|
Arrigan D, Herzog G, Scanlon M, Strutwolf J. Bioanalytical Applications of Electrochemistry at Liquid-Liquid Microinterfaces. ELECTROANALYTICAL CHEMISTRY: A SERIES OF ADVANCES 2013. [DOI: 10.1201/b15576-4] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
10
|
Alvarez de Eulate E, O'Sullivan S, Fletcher S, Newsholme P, Arrigan DWM. Ion-Transfer Electrochemistry of Rat Amylin at the Water-Organogel Microinterface Array and Its Selective Detection in a Protein Mixture. Chem Asian J 2013; 8:2096-101. [DOI: 10.1002/asia.201300215] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2013] [Indexed: 11/11/2022]
|
11
|
Stripping voltammetry at micro-interface arrays: A review. Anal Chim Acta 2013; 769:10-21. [DOI: 10.1016/j.aca.2012.12.031] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2012] [Revised: 12/04/2012] [Accepted: 12/18/2012] [Indexed: 11/18/2022]
|
12
|
Kabagambe B, Izadyar A, Amemiya S. Stripping voltammetry of nanomolar potassium and ammonium ions using a valinomycin-doped double-polymer electrode. Anal Chem 2012; 84:7979-86. [PMID: 22891987 DOI: 10.1021/ac301773w] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Here, we report on the first application of an ionophore-doped double-polymer electrode for ion-transfer stripping voltammetry (ITSV) to explore the nanomolar limit of detection (LOD) and multiple-ion detectability. We developed a theoretical model for ITSV at a thin ionophore-doped membrane on the solid supporting electrode to demonstrate that its LOD is controlled by the equilibrium preconcentration of an aqueous analyte ion as an ionophore complex into the thin polymer membrane and is lowered by the formation of a more stable ion-ionophore complex. The theoretical predictions were confirmed using valinomycin as a K(+)-selective ionophore, which forms a ∼60 times more stable complex with K(+) than with NH(4)(+), as confirmed by cyclic voltammetry. A LOD of 0.6 nM K(+) was achieved by ITSV using commercial ultrapure water as a K(+)-free media, where NH(4)(+) contamination at a higher concentration was also detected by ITSV. The dependence of the ITSV response on the preconcentration time was monitored under the rotating-electrode configuration and analyzed theoretically to directly determine ∼100 nM NH(4)(+) and ∼5 nM K(+) contaminations in commercial ultrapure water and laboratory-purified water, respectively, without the background ITSV measurement of an analyte-free blank solution.
Collapse
Affiliation(s)
- Benjamin Kabagambe
- Department of Chemistry, University of Pittsburgh, Pennsylvania 15260, United States
| | | | | |
Collapse
|
13
|
Scanlon MD, Arrigan DWM. Enhanced Electroanalytical Sensitivity via Interface Miniaturisation: Ion Transfer Voltammetry at an Array of Nanometre Liquid-Liquid Interfaces. ELECTROANAL 2011. [DOI: 10.1002/elan.201000667] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
14
|
Scanlon MD, Strutwolf J, Blake A, Iacopino D, Quinn AJ, Arrigan DWM. Ion-Transfer Electrochemistry at Arrays of Nanointerfaces between Immiscible Electrolyte Solutions Confined within Silicon Nitride Nanopore Membranes. Anal Chem 2010; 82:6115-23. [DOI: 10.1021/ac1008282] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Micheál D. Scanlon
- Tyndall National Institute, Lee Maltings, University College Cork, Cork, Ireland
| | - Jörg Strutwolf
- Tyndall National Institute, Lee Maltings, University College Cork, Cork, Ireland
| | - Alan Blake
- Tyndall National Institute, Lee Maltings, University College Cork, Cork, Ireland
| | - Daniela Iacopino
- Tyndall National Institute, Lee Maltings, University College Cork, Cork, Ireland
| | - Aidan J. Quinn
- Tyndall National Institute, Lee Maltings, University College Cork, Cork, Ireland
| | - Damien W. M. Arrigan
- Tyndall National Institute, Lee Maltings, University College Cork, Cork, Ireland
| |
Collapse
|
15
|
Strutwolf J, Arrigan DWM. Optimisation of the conditions for stripping voltammetric analysis at liquid–liquid interfaces supported at micropore arrays: a computational simulation. Anal Bioanal Chem 2010; 398:1625-31. [DOI: 10.1007/s00216-010-3866-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2010] [Revised: 05/07/2010] [Accepted: 05/20/2010] [Indexed: 10/19/2022]
|