• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4608411)   Today's Articles (4842)   Subscriber (49375)
For: Blanco S, Vargas R, Mostany J, Borrás C, Scharifker BR. A novel nickel nanowire amperometric sensor: Direct current vs. alternating current strategies for ethanol, acetaldehyde and acetylcholine detection. J Electroanal Chem (Lausanne) 2015. [DOI: 10.1016/j.jelechem.2014.12.028] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Number Cited by Other Article(s)
1
Pitiphattharabun S, Auewattanapun K, Htet TL, Thu MM, Panomsuwan G, Techapiesancharoenkij R, Ohta J, Jongprateep O. Reduced graphene oxide/zinc oxide composite as an electrochemical sensor for acetylcholine detection. Sci Rep 2024;14:14224. [PMID: 38902301 PMCID: PMC11190213 DOI: 10.1038/s41598-024-64238-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Accepted: 06/06/2024] [Indexed: 06/22/2024]  Open
2
Batool R, Riaz S, Bano S, Hayat A, Nazir MS, Nasir M, Marty JL, Nawaz MH. Fabrication of polydopamine decorated carbon cloth as support material to anchor CeO2 nanoparticles for electrochemical detection of ethanol. Mikrochim Acta 2023;190:172. [PMID: 37017829 DOI: 10.1007/s00604-023-05707-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 02/14/2023] [Indexed: 04/06/2023]
3
Zhang G, Zeng H, Liu J, Nagashima K, Takahashi T, Hosomi T, Tanaka W, Yanagida T. Nanowire-based sensor electronics for chemical and biological applications. Analyst 2021;146:6684-6725. [PMID: 34667998 DOI: 10.1039/d1an01096d] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
4
Abdullayeva N, Kumtepe A, Altaf CT, Seckin H, Sankir ND, Sankir M. Dual-Ionomer-Based Device: Acetylcholine Transport and Nonenzymatic Sensing. ACS APPLIED MATERIALS & INTERFACES 2020;12:50039-50051. [PMID: 33084309 DOI: 10.1021/acsami.0c13725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
5
Herrera EG, Bonini A, Vivaldi F, Melai B, Salvo P, Poma N, Santalucia D, Kirchhain A, Di Francesco F. A Biosensor for the Detection of Acetylcholine and Diazinon. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020;2019:1159-1162. [PMID: 31946099 DOI: 10.1109/embc.2019.8856959] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
6
Shadlaghani A, Farzaneh M, Kinser D, Reid RC. Direct Electrochemical Detection of Glutamate, Acetylcholine, Choline, and Adenosine Using Non-Enzymatic Electrodes. SENSORS (BASEL, SWITZERLAND) 2019;19:E447. [PMID: 30678261 PMCID: PMC6387276 DOI: 10.3390/s19030447] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Revised: 01/06/2019] [Accepted: 01/18/2019] [Indexed: 02/06/2023]
7
Tettamanti CS, Ramírez ML, Gutierrez FA, Bercoff PG, Rivas GA, Rodríguez MC. Nickel nanowires-based composite material applied to the highly enhanced non-enzymatic electro-oxidation of ethanol. Microchem J 2018. [DOI: 10.1016/j.microc.2018.06.023] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
8
Anithaa A, Asokan K, Sekar C. Low energy nitrogen ion beam implanted tungsten trioxide thin films modified indium tin oxide electrode based acetylcholine sensor. J Taiwan Inst Chem Eng 2018. [DOI: 10.1016/j.jtice.2018.01.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
9
Quantification of ethanol in plasma by electrochemical detection with an unmodified screen printed carbon electrode. Sci Rep 2016;6:23569. [PMID: 27006081 PMCID: PMC4804280 DOI: 10.1038/srep23569] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2015] [Accepted: 03/09/2016] [Indexed: 01/26/2023]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA