1
|
Xiang G, Xu W, Zhuge W, Huang Q, Zhang C, Peng J. A Tröger's base-linked aluminium phthalocyanine polymer for discriminative electrochemical sensing of the antibiotic isoniazid. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:1012-1020. [PMID: 38304962 DOI: 10.1039/d3ay02298f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/03/2024]
Abstract
Isoniazid is a first-line drug used to treat tuberculosis. However, its excessive use can lead to serious adverse effects. Thus, strict monitoring of the isoniazid levels in medications and human systems is required. In this study, a new polymer (AlPc-TB POP) containing a metal phthalocyanine and Tröger's base was synthesized and explored as an electrocatalyst for the oxidation of isoniazid. The results indicated that the polymer is an excellent electron-transfer medium for isoniazid oxidation. The AlPc-TB POP-based sensor quantified isoniazid in the linear range of 0.1-130 μM, with a detection limit of 0.0185 μM. The response of the developed sensor to isoniazid was reproducible and stable. Furthermore, this method can accurately determine isoniazid levels by ignoring the influence of common interfering species in tablets and biological samples. This study contributes to the development of nitrogen-rich porous organic polymers and offers a novel strategy for addressing challenges in disease therapeutic efficacy and public safety monitoring.
Collapse
Affiliation(s)
- Gang Xiang
- College of Chemical and Biological Engineering, Guangxi Normal University for Nationalities, Chongzuo, 532200, China.
- Photochemical Sensing and Regional Environmental Analysis Laboratory, Guangxi Normal University for Nationalities, Chongzuo, 532200, China
| | - Wensi Xu
- School of Pharmacy, Henan University of Traditional Chinese Medicine, Zhengzhou, 450046, China
| | - Wenfeng Zhuge
- College of Chemical and Biological Engineering, Guangxi Normal University for Nationalities, Chongzuo, 532200, China.
- Photochemical Sensing and Regional Environmental Analysis Laboratory, Guangxi Normal University for Nationalities, Chongzuo, 532200, China
| | - Qing Huang
- College of Chemical and Biological Engineering, Guangxi Normal University for Nationalities, Chongzuo, 532200, China.
- Photochemical Sensing and Regional Environmental Analysis Laboratory, Guangxi Normal University for Nationalities, Chongzuo, 532200, China
| | - Cuizhong Zhang
- College of Chemical and Biological Engineering, Guangxi Normal University for Nationalities, Chongzuo, 532200, China.
- Photochemical Sensing and Regional Environmental Analysis Laboratory, Guangxi Normal University for Nationalities, Chongzuo, 532200, China
| | - Jinyun Peng
- College of Chemical and Biological Engineering, Guangxi Normal University for Nationalities, Chongzuo, 532200, China.
- Photochemical Sensing and Regional Environmental Analysis Laboratory, Guangxi Normal University for Nationalities, Chongzuo, 532200, China
| |
Collapse
|
2
|
Aquino de Queiroz JL, Medeiros LG, Augusto da Silva K, Fontes Galvão FM, Oliveira do Nascimento JH, Martínez-Huitle CA, Castro PS. Development of recycled and miniaturized electroanalytical sensor: Probing isoniazid determination in environmental water matrices. CHEMOSPHERE 2023; 341:140030. [PMID: 37669719 DOI: 10.1016/j.chemosphere.2023.140030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 08/11/2023] [Accepted: 08/30/2023] [Indexed: 09/07/2023]
Abstract
Surface water pollution has become relevant because growing population and intense industrial activities. Thus, to protect the environment from contamination, recently the electroanalytical sensors that require small sample volume and easy preparation have shown a prominent performance for pharmaceuticals monitoring. For this purpose, a miniaturized electrochemical platform was developed based on recycling obsolete computer integrated circuits (microchips), fitting with the ideals of green chemistry and circular economy. The gold microelectrodes array (Au-μEA) was easily exposed by polishing the device surface and then characterized by optical microscopy, scanning electron microscopy and cyclic voltammetry. To enhance the analytical performance for isoniazid detection, the Au-μEA was modified with electrochemically reduced graphene oxide (ERGO). The developed sensor presented a linear range between 5 and 100 μmol L-1 and a limit of detection of 1.38 μmol L-1 demonstrating a reliable performance. Looking to its environmental application, the ERGO/Au-μEA sensor was used for isoniazid quantification in lagoon, river, tap water and synthetic effluent spiked samples with recovery values between 92.5 and 108.4%. Thus, this research field opens up new possibilities in global water-related issues contributing with innovative sustainable solutions.
Collapse
Affiliation(s)
- Jorge Leandro Aquino de Queiroz
- Federal University of Rio Grande Do Norte, Institute of Chemistry, Lagoa Nova, CEP 59.072-970, Natal, RN, Brazil; Federal Institute of Education, Science and Technology of Rio Grande Do Norte, Brazil
| | - Leonardo Gomes Medeiros
- Federal University of Rio Grande Do Norte, Institute of Chemistry, Lagoa Nova, CEP 59.072-970, Natal, RN, Brazil
| | - Kayky Augusto da Silva
- Federal University of Rio Grande Do Norte, Institute of Chemistry, Lagoa Nova, CEP 59.072-970, Natal, RN, Brazil
| | | | | | | | - Pollyana Souza Castro
- Federal University of Rio Grande Do Norte, Institute of Chemistry, Lagoa Nova, CEP 59.072-970, Natal, RN, Brazil.
| |
Collapse
|
3
|
Sivaselvam S, Viswanathan C, Ponpandian N. One-step preparation of N-doped grapheme quantum dots with high quantum yield for bioimaging and highly sensitive electrochemical detection of isoniazid. BIOMATERIALS ADVANCES 2022; 135:212731. [PMID: 35929207 DOI: 10.1016/j.bioadv.2022.212731] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 02/16/2022] [Accepted: 02/21/2022] [Indexed: 06/15/2023]
Abstract
Conventional techniques for synthesizing GQDs have a poor quantum yield (QY) that restricts their biological applications. Herein, we present a rapid, cost-effective and high quantum yield synthesis of nitrogen-doped graphene quantum dots (N-GQDs) through a scientific microwave reactor. The reaction parameters like microwave irradiation time, temperature, precursor concentration and pressure were optimized for achieving high quantum yield. The prepared N-GQDs exhibit bright blue fluorescence and excitation independent emission property with a quantum yield of 42.81%. In-vivo investigations on C. elegans revealed that the as-prepared N-GQDs are exceptionally biocompatible and maintain the normal physiological functioning of the primary and secondary targeted organs in nematodes. The synergetic effect of intestinal barrier and defecation behavior mitigates N-GQDs translocation into reproductive organs of nematode. In addition, the N-GQDs modified GCE was tested for electrochemical sensing characteristics towards the anti-tuberculosis drug isoniazid (INZ). The N-GQDs showed appreciable electrocatalytic performance towards INZ with high sensitivity (3.76 μA μM-1 cm-1). The differential pulse voltammetry (DPV) analysis of N-GQDs exhibit a lower detection limit of 10.91 nM for INZ. The N-GQDs modified sensor exhibits good reproducibility, excellent anti-interference ability and excellent analytical performance for INZ in real samples like human blood serum and urine samples.
Collapse
Affiliation(s)
- S Sivaselvam
- Department of Nanoscience and Technology, Bharathiar University, Coimbatore 641 046, India
| | - C Viswanathan
- Department of Nanoscience and Technology, Bharathiar University, Coimbatore 641 046, India
| | - N Ponpandian
- Department of Nanoscience and Technology, Bharathiar University, Coimbatore 641 046, India.
| |
Collapse
|
4
|
Voltammetric Determination of Isoniazid in the Presence of Acetaminophen Utilizing MoS2-Nanosheet-Modified Screen-Printed Electrode. MICROMACHINES 2022; 13:mi13030369. [PMID: 35334661 PMCID: PMC8955440 DOI: 10.3390/mi13030369] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 02/21/2022] [Accepted: 02/22/2022] [Indexed: 12/21/2022]
Abstract
We used MoS2 nanosheets (MoS2 NSs) for surface modification of screen-printed electrode (MoS2NSs-SPE) aimed at detecting isoniazid (INZ) in the presence of acetaminophen (AC). According to analysis, an impressive catalytic performance was found for INZ and AC electro-oxidation, resulting in an appreciable peak resolution (~320 mV) for both analytes. Chronoamperometry, differential pulse voltammetry (DPV), linear sweep voltammogram (LSV), and cyclic voltammetry (CV) were employed to characterize the electrochemical behaviors of the modified electrode for the INZ detection. Under the optimal circumstances, there was a linear relationship between the peak current of oxidation and the various levels of INZ (0.035–390.0 µM), with a narrow limit of detection (10.0 nM). The applicability of the as-developed sensor was confirmed by determining the INZ and AC in tablets and urine specimens, with acceptable recoveries.
Collapse
|
5
|
Development and characterization of electrochemical sensors based on carbon modified with TiO2 nanoparticles. HEMIJSKA INDUSTRIJA 2022. [DOI: 10.2298/hemind220105013m] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The aim of this study is the development and characterization of a
carbon-based electrochemical sensor, modified with TiO2 nanoparticles for
potential application in electroanalytical techniques. The influence of
binder and modifier contents on morphological, physicochemical and
electrochemical characteristics of the electrode material was investigated
in order to determine the optimal ratio of the carbon
material/binder/modifier. Carbon pastes were prepared from mixtures
containing graphite powder, TiO2 nanoparticles and liquid hydrocarbons.
Scanning electron microscopy showed that the electrode material becomes more
compact with the addition and the increase in the binder material content,
while increasing the proportion of TiO2 nanoparticles did not have any
significant effect on the material morphology showing fairly homogeneous
nanoparticle distribution in the graphite electrode material. The test
results indicate that the modified carbon paste with 40 vol.% paraffin oil
(PO) and 6-8 wt.% TiO2 nanoparticles is characterized by the lowest value of
specific resistance. By applying cyclic voltammetry, the most pronounced
degree of reversibility was obtained in relation to the standard reversible
redox system ([Fe (CN)]-3/-4) for the electrode material with 30-40 vol.% PO
and 8-10 wt.% TiO2 nanoparticles. Characterization of the electrode material
based on carbon modified with TiO2 nanoparticles indicated that the optimal
composition contains 40 vol.% PO and 6-8 wt.% TiO2 nanoparticles, which is
important for application in electroanalytical techniques.
Collapse
|
6
|
Inorganofunctionalization of Ti(IV) and Zr(IV) on the MCM-41 Surface and its Interaction with a Mixed Valence Complex to use as Isoniazid Sensing. J Inorg Organomet Polym Mater 2021. [DOI: 10.1007/s10904-021-02025-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
7
|
Souza Magossi M, Souza Magossi M, Dias Filho NL, Ribeiro do Carmo D. Isoniazid‐sensing Behavior of a Hybrid Silsesquioxane and Cobalt Pentacyanonitrosylferrate‐based Nanocomposite. ELECTROANAL 2021. [DOI: 10.1002/elan.202100119] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Mariana Souza Magossi
- Faculdade de Engenharia de Ilha Solteira Universidade Estadual Paulista “Júlio de Mesquita Filho” Departamento de Física e Química Av. Brasil, 56 15385-000 Ilha Solteira-SP Brazil
| | - Maiara Souza Magossi
- Faculdade de Engenharia de Ilha Solteira Universidade Estadual Paulista “Júlio de Mesquita Filho” Departamento de Física e Química Av. Brasil, 56 15385-000 Ilha Solteira-SP Brazil
| | - Newton Luiz Dias Filho
- Faculdade de Engenharia de Ilha Solteira Universidade Estadual Paulista “Júlio de Mesquita Filho” Departamento de Física e Química Av. Brasil, 56 15385-000 Ilha Solteira-SP Brazil
| | - Devaney Ribeiro do Carmo
- Faculdade de Engenharia de Ilha Solteira Universidade Estadual Paulista “Júlio de Mesquita Filho” Departamento de Física e Química Av. Brasil, 56 15385-000 Ilha Solteira-SP Brazil
| |
Collapse
|
8
|
Omar RA, Verma N, Arora PK. Development of ESAT-6 Based Immunosensor for the Detection of Mycobacterium tuberculosis. Front Immunol 2021; 12:653853. [PMID: 34093542 PMCID: PMC8170314 DOI: 10.3389/fimmu.2021.653853] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 05/04/2021] [Indexed: 12/31/2022] Open
Abstract
Early secreted antigenic target of 6 kDa (ESAT-6) has recently been identified as a biomarker for the rapid diagnosis of tuberculosis. We propose a stable and reusable immunosensor for the early diagnosis of tuberculosis based on the detection and quantification of ESAT-6 via cyclic voltammetry (CV). The immunosensor was synthesized by polymerizing aniline dispersed with the reduced graphene oxide (rGO) and Ni nanoparticles, followed by surface modification of the electroconductive polyaniline (PANI) film with anti-ESAT-6 antibody. Physicochemical characterization of the prepared materials was performed by several analytical techniques, including FE-SEM, EDX, XRD, FT-IR, Raman, TGA, TPR, and BET surface area analysis. The antibody-modified Ni-rGO-PANI electrode exhibited an approximately linear response (R2 = 0.988) towards ESAT-6 during CV measurements over the potential range of -1 to +1 V. The lower detection limit for ESAT-6 was approximately 1.0 ng mL-1. The novelty of this study includes the development of the reusable Ni-rGO-PANI-based electrochemical immunosensor for the early diagnosis of tuberculosis. Furthermore, this study successfully demonstrates that electro-conductive PANI may be used as a polymeric substrate for Ni nanoparticles and rGO.
Collapse
Affiliation(s)
- Rishabh Anand Omar
- Department of Environmental Microbiology, Babasaheb Bhimrao Ambedkar University, Lucknow, India
| | - Nishith Verma
- Centre for Environmental Science and Engineering, Indian Institute of Technology Kanpur, Kanpur, India
- Department of Chemical Engineering, Indian Institute of Technology Kanpur, Kanpur, India
| | - Pankaj Kumar Arora
- Department of Environmental Microbiology, Babasaheb Bhimrao Ambedkar University, Lucknow, India
| |
Collapse
|
9
|
Sultan S, Zulqarnain M, Shah A, Firdous N, Nisar J, Ashiq MN, Bakhsh EM, Khan SB. Bimetallic cobalt-iron diselenide nanorod modified glassy carbon electrode: an electrochemical sensing platform for the selective detection of isoniazid. RSC Adv 2021; 11:12649-12657. [PMID: 35423804 PMCID: PMC8697147 DOI: 10.1039/d1ra01572a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Accepted: 03/24/2021] [Indexed: 11/30/2022] Open
Abstract
The increasing demand of a sensitive and portable electrochemical sensing platform in pharmaceutical analysis has developed widespread interest in preparing electrode materials possessing remarkable properties for the electrochemical determination of target drug analytes. Herein, we report the synthesis, characterization and application of bimetallic cobalt-iron diselenide (FeCoSe2) nanorods as electrode modifiers for the selective detection of a commonly used anti-tuberculosis drug Isoniazid (INZ). We prepared FeCoSe2 nanorods by a simple hydrothermal route and characterized these by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDX) and temperature-programmed reduction (TPR) techniques. The electrochemical characterization of FeCoSe2 modified GCE was performed by cyclic voltammetry (CV) and square wave anodic stripping voltammetry (SWASV). Under optimized experimental conditions, a linear current-concentration response was obtained for INZ in the range of 0.03–1.0 μM, with very low limit of detection 1.24 × 10−10 M. The real applicability of the designed FeCoSe2/GCE sensing platform was adjudicated by the detection of INZ in biological samples. FeCoSe2 bimetallic nanorods were synthesized by hydrothermal method. The modified electrode responded excellently towards isoniazid detection with LOD of 1.24 × 10−10 M. FeCoSe2/GCE showed applicability for INZ detection in real samples.![]()
Collapse
Affiliation(s)
- Sundas Sultan
- Department of Chemistry, Quaid-i-Azam University Islamabad 45320 Pakistan
| | | | - Afzal Shah
- Department of Chemistry, Quaid-i-Azam University Islamabad 45320 Pakistan
| | - Naveeda Firdous
- Department of Chemistry, Quaid-i-Azam University Islamabad 45320 Pakistan
| | - Jan Nisar
- National Centre of Excellence in Physical Chemistry, University of Peshawar Peshawar 25120 Pakistan
| | - Muhammad Naeem Ashiq
- Institute of Chemical Sciences, Bahauddin Zakaryia University Multan 6100 Pakistan
| | - Esraa M Bakhsh
- Department of Chemistry, King Abdulaziz University P. O. Box 80203 Jeddah 21589 Saudi Arabia
| | - Sher Bahadar Khan
- Department of Chemistry, King Abdulaziz University P. O. Box 80203 Jeddah 21589 Saudi Arabia
| |
Collapse
|
10
|
Rajasekhar Chokkareddy, Gan G Redhi. A Facile Electrochemical Sensor Based on Ionic Liquid Functionalized Multiwalled Carbon Nanotubes for Isoniazid Detection. JOURNAL OF ANALYTICAL CHEMISTRY 2020. [DOI: 10.1134/s1061934820120059] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
11
|
Zhu L, Li X, Deng Y, Zou R, Shao B, Yan L, Ruan C, Sun W. Construction and electrochemical behavior of hemoglobin sensor based on ZnO doped carbon nanofiber modified electrode. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2020. [DOI: 10.1007/s13738-020-02088-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
12
|
Azimi A, Akhond M, Ashrafi H, Absalan G. Silver nanoparticles loaded on a hybrid of graphitic carbon nitride and reduced graphene oxide as a modifier for carbon paste electrode in determination of isoniazid. MONATSHEFTE FUR CHEMIE 2020. [DOI: 10.1007/s00706-020-02647-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
13
|
Mohammadi SZ, Beitollahi H, Kaykhaii M, Mohammadizadeh N. A Novel Electrochemical Sensor Based on Graphene Oxide Nanosheets and Ionic Liquid Binder for Differential Pulse Voltammetric Determination of Droxidopa in Pharmaceutical and Urine Samples. RUSS J ELECTROCHEM+ 2020. [DOI: 10.1134/s1023193519120127] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
14
|
Electroanalysis of isoniazid and rifampicin: Role of nanomaterial electrode modifiers. Biosens Bioelectron 2019; 146:111731. [PMID: 31614253 DOI: 10.1016/j.bios.2019.111731] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2019] [Revised: 09/22/2019] [Accepted: 09/23/2019] [Indexed: 02/02/2023]
Abstract
Thanks to operational simplicity, speediness, possibility of miniaturization and real-time nature, electrochemical sensing is a supreme alternative for non-electrochemical methodologies in drug quantification. This review, highlights different nanotech-based sensory designs for electroanalysis of isoniazid and rifampicin, the most important medicines for patients with tuberculosis. We first, concisely mention analyses with bare electrodes, associated impediments and inspected possible strategies and then critically review the last two decades works with focus on different nano-scaled electrode modifiers. We organized and described the materials engaged in several categories: Surfactants modifiers, polymeric modifiers, metallic nanomaterials, carbon based nano-modifiers (reduced graphene oxide, multi-walled carbon nanotubes, ordered mesoporous carbon) and a large class of multifarious nano composites-based sensors and biosensors. The main drawbacks and superiorities associated with each array as well as the current trend in the areas is attempted to discuss. Summary of 79 employed electrochemical approaches for analysis of isoniazid and rifampicin has also been presented.
Collapse
|
15
|
Özdokur KV. Voltammetric Determination of Isoniazid Drug in Various Matrix by Using CuO
x
Decorated MW‐CNT Modified Glassy Carbon Electrode. ELECTROANAL 2019. [DOI: 10.1002/elan.201900307] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Affiliation(s)
- K. Volkan Özdokur
- Erzincan Binali Yıldırım UniversityFaculty of Science and Letter, Department of Chemistry Erzincan Turkey
| |
Collapse
|
16
|
Ozcelikay G, Karadurmus L, Kaya SI, Bakirhan NK, Ozkan SA. A Review: New Trends in Electrode Systems for Sensitive Drug and Biomolecule Analysis. Crit Rev Anal Chem 2019; 50:212-225. [PMID: 31107105 DOI: 10.1080/10408347.2019.1615406] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Drug and biomolecule analysis with high precision, fast response, not expensive, and user-friendly methods have been very important for developing technology and clinical applications. Electrochemical methods are highly capable for assaying the concentration of electroactive drug or biomolecule and supply excellent knowledge concerning its physical and chemical properties such as electron transfer rates, diffusion coefficients, electron transfer number, and oxidation potential. Electrochemical methods have been widely applied because of their accuracy, sensitivity, cheapness, and can applied on-site determinations of various substances. The progress on electronics has allowed developing reliable, more sensitive and less expensive instrumentations, which have significant contribution in the area of drug development, drug and biomolecule analysis. The developing new sensors for electrochemical analysis of these compounds have growing interest in recent years. Screen-printed based electrodes have a great interest in electrochemical analysis of various drugs and biomolecules due to their easy manufacturing procedure of the electrode allow the transfer of electrochemical laboratory experiments for disposable on-site analysis of some compounds. Paper based electrodes are also fabricated by new technology. They can be preferred due to their easy, cheap, portable, disposable, and offering high sensitivity properties for many application field such as environmental monitoring, food quality control, clinical diagnosis, drug, and biomolecules analysis. In this review, the recent electrochemical drug and biomolecule (DNA, RNA, µRNA, Biomarkers, etc.) studies will be presented that involve new trend disposable electrodes.
Collapse
Affiliation(s)
- Goksu Ozcelikay
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Leyla Karadurmus
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey.,Department of Analytical Chemistry, Faculty of Pharmacy, Adıyaman University, Adıyaman, Turkey
| | - S Irem Kaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Nurgul K Bakirhan
- Department of Chemistry, Arts & Sciences Faculty, Hitit University, Corum, Turkey
| | - Sibel A Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
17
|
Srivastava AK, Upadhyay SS, Rawool CR, Punde NS, Rajpurohit AS. Voltammetric Techniques for the Analysis of Drugs using Nanomaterials based Chemically Modified Electrodes. CURR ANAL CHEM 2019. [DOI: 10.2174/1573411014666180510152154] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Electroanalytical techniques play a very important role in the areas of medicinal,
clinical as well as pharmaceutical research. Amongst these techniques, the voltammetric methods
for the determination of drugs using nanomaterials based chemically modified electrodes (CMEs)
have received enormous attention in recent years. This is due to the sensitivity and selectivity they
provide on qualitative as well as quantitative aspects of the electroactive analyte under study. The aim
of the present review was to discuss the work on nanomaterials based CMEs for the analysis of drugs
covering the period from 2000 to present employing various voltammetric techniques for different
classes of the drugs.
Methods:
The present review deals with the determination of different classes of drugs including analgesics,
anthelmentic, anti-TB, cardiovascular, antipsychotics and anti-allergic, antibiotic and gastrointestinal
drugs. Also, a special section is devoted for enantioanalysis of certain chiral drugs using
voltammetry. The detailed information of the voltammetric determination for the drugs from each
class employing various techniques such as differential pulse voltammetry, cyclic voltammetry, linear
sweep voltammetry, square wave voltammetry, stripping voltammetry, etc. are presented in tabular
form below the description of each class in the review.
Results:
Various nanomaterials including carbon nanotubes, graphene, carbon nanofibers, quantum
dots, metal/metal oxide nanoparticles, polymer based nanocomposites have been used by researchers
for the development of CMEs over a period of time. The large surface area to volume ratio, high conductivity,
electrocatalytic activity and biocompatibility make them ideal modifiers where they produce
synergistic effect which helps in trace level determination of pharmaceutical, biomedical and medicinal
compounds. In addition, macrocyclic compounds as chiral selectors have been used for the determination
of enantiomeric drugs where one of the isomers captured in the cavities of chiral selector
shows stronger binding interaction for one of the enantiomorphs.
Conclusion:
arious kinds of functional nanocomposites have led to the manipulation of peak potential
due to drug - nanoparticles interaction at the modified electrode surface. This has facilitated the
simultaneous determination of drugs with almost similar peak potentials. Also, it leads to the enhancement
in voltammetric response of the analytes. It is expected that such modified electrodes can
be easily miniaturized and used as portable, wearable and user friendly devices. This will pave a way
for in-vivo onsite real monitoring of single as well as multi component pharmaceutical compounds.
Collapse
Affiliation(s)
- Ashwini K. Srivastava
- Department of Chemistry, University of Mumbai, Vidyanagari, Santacruz (East), Mumbai, 400 098, India
| | - Sharad S. Upadhyay
- Department of Chemistry, University of Mumbai, Vidyanagari, Santacruz (East), Mumbai, 400 098, India
| | - Chaitali R. Rawool
- Department of Chemistry, University of Mumbai, Vidyanagari, Santacruz (East), Mumbai, 400 098, India
| | - Ninad S. Punde
- Department of Chemistry, University of Mumbai, Vidyanagari, Santacruz (East), Mumbai, 400 098, India
| | - Anuja S. Rajpurohit
- Department of Chemistry, University of Mumbai, Vidyanagari, Santacruz (East), Mumbai, 400 098, India
| |
Collapse
|
18
|
Zhang Y, Jiang X, Zhang J, Zhang H, Li Y. Simultaneous voltammetric determination of acetaminophen and isoniazid using MXene modified screen-printed electrode. Biosens Bioelectron 2019; 130:315-321. [DOI: 10.1016/j.bios.2019.01.043] [Citation(s) in RCA: 156] [Impact Index Per Article: 31.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Revised: 12/24/2018] [Accepted: 01/16/2019] [Indexed: 12/12/2022]
|
19
|
Kokulnathan T, Suvina V, Wang TJ, Balakrishna RG. Synergistic design of a tin phosphate-entrapped graphene flake nanocomposite as an efficient catalyst for electrochemical determination of the antituberculosis drug isoniazid in biological samples. Inorg Chem Front 2019. [DOI: 10.1039/c9qi00254e] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
A SnP/GRF-modified electrode has potential application in the electrochemical detection of ISZ.
Collapse
Affiliation(s)
- Thangavelu Kokulnathan
- Department of Electro-Optical Engineering
- National Taipei University of Technology
- Taipei-10608
- Taiwan
| | - V. Suvina
- Centre for Nano and Material Sciences
- Jain Global Campus
- Jain University
- Bangalore-562112
- India
| | - Tzyy-Jiann Wang
- Department of Electro-Optical Engineering
- National Taipei University of Technology
- Taipei-10608
- Taiwan
| | - R. Geetha Balakrishna
- Centre for Nano and Material Sciences
- Jain Global Campus
- Jain University
- Bangalore-562112
- India
| |
Collapse
|
20
|
Direct electroiodimetric sensing of reducing biomolecules using a modified multiwall carbon nanotube/ionic liquid paste electrode by tetra-n-octylammonium triiodide. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.09.125] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
21
|
Liu C, Li X, Li X, Xu T, Song C, Ogino K, Gu Z. Preparation of Conductive Polyester Fibers Using Continuous Two-Step Plating Silver. MATERIALS 2018; 11:ma11102033. [PMID: 30347665 PMCID: PMC6212803 DOI: 10.3390/ma11102033] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Revised: 10/15/2018] [Accepted: 10/17/2018] [Indexed: 11/19/2022]
Abstract
Polyester fibers are used in various fields, due to their excellent mechanical and chemical stability. However, the lack of conductivity limits their application potential. In order to prepare conductive polyester fibers, silver is one of the most widely used materials to coat the surface of the fibers. This work aimed to prepare silver-coated polyester fibers by a continuous two-step method, which combined the operations of continuous electroless plating and electroplating. Meanwhile, we designed specialized equipment for the continuous plating of silver on the polyester fibers under a dynamic condition. The mechanical property, washability, electrical resistivity, and electrical conductivity of the resultant conductive polyester fibers obtained from different silver-plating conditions were also characterized. The results demonstrated that the conductive fibers prepared by continuous two-step silver plating equipment, had good electrical conductivity with better mechanical properties and washability.
Collapse
Affiliation(s)
- Changchun Liu
- Graduate School of Bio-Applications and Systems Engineering, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588, Japan.
- College of Chemistry and Materials Engineering, Changzhou Vocational Institute of Engineering, Changzhou 213164, China.
| | - Xuelian Li
- College of Chemistry and Materials Engineering, Changzhou Vocational Institute of Engineering, Changzhou 213164, China.
| | - Xiaoqiang Li
- College of Textile and Clothing, Jiangnan University, Wuxi 214122, China.
| | - Tianze Xu
- School of Materials Science and Engineering, Tianjin University, Tianjin 300350, China.
| | - Chunyu Song
- College of Textile and Clothing, Jiangnan University, Wuxi 214122, China.
| | - Kenji Ogino
- Graduate School of Bio-Applications and Systems Engineering, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588, Japan.
| | - Zhijie Gu
- Graduate School of Bio-Applications and Systems Engineering, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588, Japan.
| |
Collapse
|
22
|
Gopinathan M, Thiyagarajan N, Thiruppathi M, Zen JM. Electrocatalytic Oxidation and Flow Injection Analysis of Isoniazid Drug Using an Unmodified Screen Printed Carbon Electrode in Neutral pH. ELECTROANAL 2018. [DOI: 10.1002/elan.201800021] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
| | | | - Murugan Thiruppathi
- Department of Chemistry; National Chung Hsing University; Taichung 402 Taiwan
| | - Jyh-Myng Zen
- Department of Chemistry; National Chung Hsing University; Taichung 402 Taiwan
| |
Collapse
|
23
|
Absalan G, Akhond M, Karimi R, Ramezani AM. Simultaneous determination of captopril and hydrochlorothiazide by using a carbon ionic liquid electrode modified with copper hydroxide nanoparticles. Mikrochim Acta 2018; 185:97. [DOI: 10.1007/s00604-017-2630-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2017] [Accepted: 12/22/2017] [Indexed: 12/01/2022]
|
24
|
Voltammetric sensing based on the use of advanced carbonaceous nanomaterials: a review. Mikrochim Acta 2018; 185:89. [PMID: 29594390 DOI: 10.1007/s00604-017-2626-0] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2017] [Accepted: 12/17/2017] [Indexed: 12/11/2022]
Abstract
This review (with 210 references) summarizes recent developments in the design of voltammetric chemical sensors and biosensors based on the use of carbon nanomaterials (CNMs). It is divided into subsections starting with an introduction into the field and a description of its current state. This is followed by a large section on various types of voltammetric sensors and biosensors using CNMs with subsections on sensors based on the use of carbon nanotubes, graphene, graphene oxides, graphene nanoribbons, fullerenes, ionic liquid composites with CNMs, carbon nanohorns, diamond nanoparticles, carbon dots, carbon nanofibers and mesoporous carbon. The third section gives conclusion and an outlook. Tables are presented on the application of such sensors to voltammetric detection of neurotransmitters, metabolites, dietary minerals, proteins, heavy metals, gaseous molecules, pharmaceuticals, environmental pollutants, food, beverages, cosmetics, commercial goods and drugs of abuse. The authors also describe advanced approaches for the fabrication of robust functional carbon nano(bio)sensors for voltammetric quantification of multiple targets. Graphical Abstract Featuring execellent electrical, catalytic and surface properies, CNMs have gained enormous attention for designing voltammetric sensors and biosensors. Functionalized CNM-modified electrode interfaces have demonstrated their prominent role in biological, environmental, pharmaceutical, chemical, food and industrial analysis.
Collapse
|
25
|
Nellaiappan S, Kumar AS. Electrocatalytic oxidation and flow injection analysis of isoniazid drug using a gold nanoparticles decorated carbon nanofibers-chitosan modified carbon screen printed electrode in neutral pH. J Electroanal Chem (Lausanne) 2017. [DOI: 10.1016/j.jelechem.2017.07.049] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
26
|
Chokkareddy R, Bhajanthri NK, Redhi GG. An Enzyme-Induced Novel Biosensor for the Sensitive Electrochemical Determination of Isoniazid. BIOSENSORS-BASEL 2017; 7:bios7020021. [PMID: 28587260 PMCID: PMC5487961 DOI: 10.3390/bios7020021] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2017] [Revised: 05/26/2017] [Accepted: 05/27/2017] [Indexed: 12/04/2022]
Abstract
In this present work, a glassy carbon electrode (GCE) was modified primarily with multiwalled carbon nanotubes (MWCNTs) and a composite of MWCNTs and titanium oxide nanoparticles (TiO2NPs). The enzyme horseradish peroxidase (HRP) was immobilized to enhance the sensing ability of GCE. The proposed biosensor was used for the sensitive determination of isoniazid (INZ) in various pharmaceutical samples. The electrochemical behaviour of the developed MWCNT-TiO2NPs-HRP-GCE biosensor was studied by using cyclic voltammetry (CV) and differential pulse voltammetric (DPV) techniques. Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), thermogravimetry (TGA) and transmission electron microscopy (TEM) techniques were used to characterize the developed sensor. Phosphate buffer solution (PBS) with pH 7 was used as supporting electrolyte in the present investigation. The cyclic voltammetric results revealed that the increment of anodic peak currents for the enzyme-induced sensor was almost 8-fold greater than that of a bare GCE. The DPV technique exhibited good limit of detection and limit of quantification values, viz., 0.0335 μM and 0.1118 μM, respectively. Moreover, the developed sensor showed long-lasting stability and repeatability without any interferents. This strongly indicates that the fabricated sensor shows outstanding electrochemical performance towards INZ, with excellent selectivity and sensitivity. The developed sensor was successfully applied to pharmaceutical samples and gave good percentages of recoveries.
Collapse
Affiliation(s)
- Rajasekhar Chokkareddy
- Electroanalytical Laboratory, Department of Chemistry, Durban University of Technology, Durban 4000, South Africa.
| | - Natesh Kumar Bhajanthri
- Electroanalytical Laboratory, Department of Chemistry, Durban University of Technology, Durban 4000, South Africa.
| | - Gan G Redhi
- Electroanalytical Laboratory, Department of Chemistry, Durban University of Technology, Durban 4000, South Africa.
| |
Collapse
|
27
|
Shiri S, Pajouheshpoor N, Khoshsafar H, Amidi S, Bagheri H. An electrochemical sensor for the simultaneous determination of rifampicin and isoniazid using a C-dots@CuFe2O4 nanocomposite modified carbon paste electrode. NEW J CHEM 2017. [DOI: 10.1039/c7nj03029k] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In this study, a sensitive carbon paste electrode based on a novel nanocomposite of carbon dots/CuFe2O4 (C-dots@CuFe2O4) was developed for the simultaneous determination of rifampicin (RIF) and isoniazid (INZ).
Collapse
Affiliation(s)
- Sajad Shiri
- Chemical Injuries Research Center
- Systems Biology and Poisonings Institute
- Baqiyatallah University of Medical Sciences
- Tehran
- Iran
| | - Niyoosha Pajouheshpoor
- Faculty of Pharmaceutical Chemistry
- Pharmaceutical Sciences Branch
- Islamic Azad University
- Tehran
- Iran
| | | | - Salimeh Amidi
- Department of Medicinal Chemistry
- School of Pharmacy
- Shahid Beheshti University of Medical Sciences
- Tehran
- Iran
| | - Hasan Bagheri
- Chemical Injuries Research Center
- Systems Biology and Poisonings Institute
- Baqiyatallah University of Medical Sciences
- Tehran
- Iran
| |
Collapse
|
28
|
Spindola RF, Zanin H, Macena CS, Contin A, de Cássia Silva Luz R, Damos FS. Evaluation of a novel composite based on functionalized multi-walled carbon nanotube and iron phthalocyanine for electroanalytical determination of isoniazid. J Solid State Electrochem 2016. [DOI: 10.1007/s10008-016-3451-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|