1
|
Fathima A, Ilankoon IMSK, Zhang Y, Chong MN. Scaling up of dual-chamber microbial electrochemical systems - An appraisal using systems design approach. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 912:169186. [PMID: 38086487 DOI: 10.1016/j.scitotenv.2023.169186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 12/04/2023] [Accepted: 12/05/2023] [Indexed: 01/18/2024]
Abstract
Impetus to minimise the energy and carbon footprints of evolving wastewater resource recovery facilities has promoted the development of microbial electrochemical systems (MES) as an emerging energy-neutral and sustainable platform technology. Using separators in dual-chamber MES to isolate anodic and cathodic environments creates endless opportunities for its myriad applications. Nevertheless, the high internal resistance and the complex interdependencies among various system factors have challenged its scale-up. This critical review employed a systems approach to examine the complex interdependencies and practical issues surrounding the implementation and scalability of dual-chamber MES, where the anodic and cathodic reactions are mutually appraised to improve the overall system efficiency. The robustness and stability of anodic biofilms in large-volume MES is dependent on its inoculum source, antecedent history and enrichment strategies. The composition and anode-respiring activity of these biofilms are modulated by the anolyte composition, while their performance demands a delicate balance between the electrode size, macrostructure and the availability of substrates, buffers and nutrients when using real wastewater as anolyte. Additionally, the catholyte governed the reduction environment and associated energy consumption of MES with scalable electrocatalysts needed to enhance the sluggish reaction kinetics for energy-efficient resource recovery. A comprehensive assessment of the dual-chamber reactor configuration revealed that the tubular, spiral-wound, or plug-in modular MES configurations are suitable for pilot-scale, where it could be designed more effectively using efficient electrode macrostructure, suitable membranes and bespoke strategies for continuous operation to maximise their performance. It is anticipated that the critical and analytical understanding gained through this review will support the continuous development and scaling-up of dual-chamber MES for prospective energy-neutral treatment of wastewater and simultaneous circular management of highly relevant environmental resources.
Collapse
Affiliation(s)
- Arshia Fathima
- Department of Chemical Engineering, School of Engineering, Monash University Malaysia, Jalan Lagoon Selatan, 47500 Bandar Sunway, Selangor, Malaysia
| | - I M S K Ilankoon
- Department of Chemical Engineering, School of Engineering, Monash University Malaysia, Jalan Lagoon Selatan, 47500 Bandar Sunway, Selangor, Malaysia
| | - Yifeng Zhang
- Department of Environmental Engineering, Technical University of Denmark, DK-2800 Lyngby, Denmark
| | - Meng Nan Chong
- Department of Chemical Engineering, School of Engineering, Monash University Malaysia, Jalan Lagoon Selatan, 47500 Bandar Sunway, Selangor, Malaysia.
| |
Collapse
|
2
|
Jia L, Cheng X, Fang L, Huang X. Nitrogen removal in improved subsurface wastewater infiltration system: Mechanism, microbial indicators and the limitation of phosphorus. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2023; 335:117456. [PMID: 36822044 DOI: 10.1016/j.jenvman.2023.117456] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 01/25/2023] [Accepted: 02/02/2023] [Indexed: 06/18/2023]
Abstract
To enhance the nitrogen removal capacity, scrap iron filings and Si-Al porous clay mineral material (PCMW) was used to improve a subsurface wastewater infiltration system (SWIS). The results showed TN and NH4+-N removal efficiencies of improved SWIS were 20.72% and 5.49% higher than those of the control SWIS, respectively. Based on the response of the removal performance, microbial community and function analysis of 16s rRNA amplicon sequencing results, the amending soil matrix substantially enriched the nitrogen removal bacteria (Rhizobiales_Incertae_Sedis and Gemmatimonadaceae), and significantly improved the activities of key enzymes (Hao, NasAB, NarGHI, NirK, NorBC, NirA and NirBD), particularly at co-occurrence zone of nitrification and denitrification (70-130 cm depth). The amending soil matrix not only extended the growth space of microbes, but also provided additional electrons and carbon sources for denitrifying bacteria by regulating the structure and function of the microbial community. In addition, amending soil matrix could enhance phosphate metabolism genes and phosphate solubilizing microbes in the denitrification zone by increasing the phosphorus source, thus strengthening nitrogen metabolism. Nitrospiraceae, Rhizobiales_Incertae_Sedis and Gemmatimonadaceae related to nitrogen removal and Bacillaceae with phosphate-solubilizing ability could be used as microbial indicators of nitrogen removal in SWISs. The reciprocal action of environmental on microbial characteristics exhibited microbial functional were related to DO, Fe2+, TOC, TP, TN, NH4+-N and NO3--N. Those could be used as physicochemical and biological indicators for application and monitoring of SWIS. In conclusion, this study provided a low-cost and efficient enhancement approach for the application of SWIS in decentralized domestic sewage treatment, and furnished theoretical support for subsequent applications.
Collapse
Affiliation(s)
- Liping Jia
- College of Chemistry and Environmental Science, Minnan Normal University, Zhangzhou, 363000, China
| | - Xuelin Cheng
- College of Chemistry and Environmental Science, Minnan Normal University, Zhangzhou, 363000, China
| | - Linchuan Fang
- CAS Center for Excellence in Quaternary Science and Global Change, Xi'an, 710061, China
| | - Xuguang Huang
- College of Chemistry and Environmental Science, Minnan Normal University, Zhangzhou, 363000, China.
| |
Collapse
|
3
|
Wang Z, Liao C, Zhong Z, Liu S, Li M, Wang X. Design, optimization and application of a highly sensitive microbial electrolytic cell-based BOD biosensor. ENVIRONMENTAL RESEARCH 2023; 216:114533. [PMID: 36241074 DOI: 10.1016/j.envres.2022.114533] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 09/24/2022] [Accepted: 10/05/2022] [Indexed: 06/16/2023]
Abstract
Biochemical oxygen demand (BOD) is an important biochemical indicator for determining the degree of water pollution and guiding the design of wastewater treatment processes. BOD sensors based on microbial electrochemical technology can conduct real-time online monitoring of organic matter and have attracted extensive attention. However, research on microbial electrolytic cell (MEC)-type BOD sensors is at the stage of theoretical exploration. Here, we designed and optimized a highly sensitive MEC-type BOD sensor by screening inoculants, comparing electrode materials, and optimizing the reactor configuration. The results showed that effective means to optimize a BOD sensor for fast activation and sensitive testing included the inoculation of the MEC reactor effluent with large amounts of biomass and highly active bacteria, selection of carbon felt electrodes with excellent adsorption and permeability, miniaturization of the reactor, regulation of suitable electrode spacing, and design of the penetrating fluid structure. Then, the optimized sensing system was applied to determine the BOD concentration in model solutions of sodium acetate in a laboratory environment, where it accurately measured BOD concentrations in the range of 10-500 mg/L and maintained good parallelism during long-term operation. Next, the MEC-type BOD sensors were put into practice in the field as an alarm for accidents at an actual sewage plant. The whole BOD sensing system was quickly assembled on site and started up, and it gave an early warning shortly after the concentration of organic matter in the water suddenly increased, thus showing a high potential for engineering applications. This study broadened the domains of application of MEC-type BOD sensors in environmental monitoring, and promoted the development of technological innovation in water ecology and environmental monitoring.
Collapse
Affiliation(s)
- Ziyuan Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Chengmei Liao
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China.
| | - Zihan Zhong
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Siyan Liu
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Ming Li
- Engelbart (Beijing) Ecological Technology Co., Ltd, Beijing Shunyi Sino-German Industrial Park Sino-German Building 6F, Beijing, 101399, China
| | - Xin Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China.
| |
Collapse
|
4
|
Zou C, Wang M, Chen Y, Qin Y, Zhao Y, Qiao L, Zhu S, Chen T, Yuan Y. Effects of different cathodic potentials on performance, microbial community structure and function for bioelectrochemical-stimulated dechlorination of 2,4,6-trichlorophenol in sediments. ENVIRONMENTAL RESEARCH 2023; 216:114477. [PMID: 36202244 DOI: 10.1016/j.envres.2022.114477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2022] [Revised: 09/27/2022] [Accepted: 09/29/2022] [Indexed: 06/16/2023]
Abstract
Bioelectrochemical systems with biocathodes constitute a promising means to enhance the biological dechlorination of 2,4,6-trichlorophenol (2,4,6-TCP) in constructed wetland (CW) sediments. However, the effect of different cathodic potentials on the structure and function of 2,4,6-TCP-reducing biocathode communities in CW sediments is largely unknown. Here, we evaluated the performance and microbial community structure of 2,4,6-TCP-reducing biocathode systems at different cathodic potentials (- 0.5, - 0.7, - 0.9, and - 1.1 V vs. saturated calomel electrode). The dechlorination efficiency of 2,4,6-TCP with the biocathode relatively increased by 16.02%-33.17% compared to that in the open circuit. The highest 2,4,6-TCP dechlorination efficiency (92.34 ± 0.86%) was observed at - 0.7 V in sediment, which may be due to the highest abundance of functional genera (e.g., Pseudomonas, Spirochaeta) at - 0.7 V. Metagenomic analysis provided new insights into the metabolic potential of microorganisms in CW sediments and suggested possible 2,4,6-TCP conversion pathways in sediments. 2,4,6-TCP was gradually dechlorinated to form 4-chlorophenol, followed by a ring-opening step via the activities of chlorophenol reductive dehalogenase and oxygenase (e.g., cprA, tfdB). Interestingly, micro-electrical stimulation enhanced the expression of chlorophenol reductive dehalogenase (cprA). Therefore, our findings at the molecular and gene expression levels provide insights into the effects of different cathodic potentials on the performance and community structure of 2,4,6-TCP-reducing biocathode systems in CW sediments.
Collapse
Affiliation(s)
- Chao Zou
- School of Environmental Science and Engineering, Yancheng Institute of Technology, Yancheng, 224051, PR China; Wuxi Huicheng Water Group Co., Ltd, Wuxi, 214174, PR China
| | - Mansi Wang
- School of Environmental Science and Engineering, Yancheng Institute of Technology, Yancheng, 224051, PR China
| | - Yixin Chen
- School of Environmental Science and Engineering, Yancheng Institute of Technology, Yancheng, 224051, PR China
| | - Yu Qin
- School of Environmental Science and Engineering, Yancheng Institute of Technology, Yancheng, 224051, PR China
| | - Yun Zhao
- School of Environmental Science and Engineering, Yancheng Institute of Technology, Yancheng, 224051, PR China
| | - Liang Qiao
- School of Environmental Science and Engineering, Yancheng Institute of Technology, Yancheng, 224051, PR China; Jiangsu Province Engineering Research Center of Intelligent Environmental Protection Equipment, Yancheng Institute of Technology, Yancheng, 224051, PR China
| | - Shasha Zhu
- School of Environmental Science and Engineering, Yancheng Institute of Technology, Yancheng, 224051, PR China; Jiangsu Province Engineering Research Center of Intelligent Environmental Protection Equipment, Yancheng Institute of Technology, Yancheng, 224051, PR China
| | - Tianming Chen
- School of Environmental Science and Engineering, Yancheng Institute of Technology, Yancheng, 224051, PR China; Jiangsu Province Engineering Research Center of Intelligent Environmental Protection Equipment, Yancheng Institute of Technology, Yancheng, 224051, PR China.
| | - Ye Yuan
- School of Environmental Science and Engineering, Yancheng Institute of Technology, Yancheng, 224051, PR China; Jiangsu Province Engineering Research Center of Intelligent Environmental Protection Equipment, Yancheng Institute of Technology, Yancheng, 224051, PR China.
| |
Collapse
|
5
|
Li Y, Feng K, Wu C, Mei J, Zhang S, Ye J, Chen J, Zhao J, Chen J. Mass transfer and reaction simultaneously enhanced airlift microbial electrolytic cell system with high gaseous o-xylene removal capacity. CHEMOSPHERE 2022; 291:132888. [PMID: 34780742 DOI: 10.1016/j.chemosphere.2021.132888] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 11/09/2021] [Accepted: 11/11/2021] [Indexed: 06/13/2023]
Abstract
To overcome the limitation of mass transfer and reaction rate involved in the biodegradation of gaseous o-xylene, the airlift reactor and microbial electrolysis cell were integrated to construct an airlift microbial electrolysis cell (AL-MEC) system for the first time, in which the bioanode was modified by polypyrrole to further improve biofilm attachment. The developed AL-MEC system achieved 95.4% o-xylene removal efficiency at optimized conditions, and maintained around 75% removal efficiency even while the inlet o-xylene load was as high as 684 g m-3 h-1. The existence of O2 exhibited a competition in electrons with the bioanode but a positive effect on ring-opening process in the o-xylene oxidation. The limitation of mass transfer had been overcome as the empty bed resistance time in the range of 20-80 s did not influence the system performance significantly. The microbial community analysis confirmed the o-xylene degradation microbes and electroactive bacteria were the dominant, which could be further enriched at 0.3 V against standard hydrogen electrode. This work revealed the feasibility of the AL-MEC system for the degradation of o-xylene and similar compounds, and provided insights into bioelectrochemical system design with high gaseous pollution removal capacity.
Collapse
Affiliation(s)
- Yuanming Li
- College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua, 321004, China
| | - Ke Feng
- Key Laboratory of Microbial Technology for Industrial Pollution Control of Zhejiang Province, College of Environment, Zhejiang University of Technology, Hangzhou, 310014, China
| | - Chao Wu
- Eco-environmental Science Research & Design Institute of Zhejiang Province, Hangzhou, 310007, China
| | - Ji Mei
- College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua, 321004, China
| | - Shihan Zhang
- Key Laboratory of Microbial Technology for Industrial Pollution Control of Zhejiang Province, College of Environment, Zhejiang University of Technology, Hangzhou, 310014, China
| | - Jiexu Ye
- Key Laboratory of Microbial Technology for Industrial Pollution Control of Zhejiang Province, College of Environment, Zhejiang University of Technology, Hangzhou, 310014, China
| | - Jianmeng Chen
- Key Laboratory of Microbial Technology for Industrial Pollution Control of Zhejiang Province, College of Environment, Zhejiang University of Technology, Hangzhou, 310014, China
| | - Jingkai Zhao
- Key Laboratory of Microbial Technology for Industrial Pollution Control of Zhejiang Province, College of Environment, Zhejiang University of Technology, Hangzhou, 310014, China.
| | - Jianrong Chen
- College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua, 321004, China.
| |
Collapse
|
6
|
A systematic study on self-powered microbial fuel cell based BOD biosensors running under different temperatures. Biochem Eng J 2022. [DOI: 10.1016/j.bej.2022.108372] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
7
|
Dai Y, Guo Y, Wang J, Li Y, Zhang L, Liu X. A vertically configured photocatalytic-microbial fuel cell for electricity generation and gaseous toluene degradation. CHEMOSPHERE 2021; 285:131530. [PMID: 34273692 DOI: 10.1016/j.chemosphere.2021.131530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 07/01/2021] [Accepted: 07/09/2021] [Indexed: 06/13/2023]
Abstract
A vertically configured photocatalytic-microbial fuel cell (photo-MFC) is developed by combining a nanodiamond-decorated ZnO (ZnO/ND) photocathode with a bioanode. The system can effectively couple the light energy with bioenergy to enhance the degradation of volatile organic compounds (VOCs) and boost electricity output. Results show that the composite system exhibits increased performance for toluene removal (60.65%), higher than those of individual parts (ZnO/ND-photocatalysis: 37.16%, MFC: 17.81%). Furthermore, its electrochemical performance is dramatically increased. The peak power density of 120 mW/m2 and the current density of 1.07 A/m2 are generated under light illumination, which are about 1.57-fold and 1.37-fold higher than that under dark (76 mW/m2, 0.78 A/m2), respectively. Microbial community analysis demonstrates Proteobacteria and Firmicute are dominant phyla, implying they play important roles on accelerating the extracellular-electron transfer and toluene degradation. In addition, the underlying mechanism for toluene degradation in the photo-MFC system is preliminary explored. Our results suggest that the photo-MFC has great potential for simultaneous treatment of VOCs with energy recovery.
Collapse
Affiliation(s)
- Yexin Dai
- Tianjin Key Lab. of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, 300354, PR China
| | - Yajing Guo
- Tianjin Key Lab. of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, 300354, PR China
| | - Jiao Wang
- Tianjin Key Lab. of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, 300354, PR China
| | - Yunxue Li
- Tianjin Key Lab. of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, 300354, PR China
| | - Lei Zhang
- School of Life Science, Tianjin University, Tianjin, 300372, PR China
| | - Xianhua Liu
- Tianjin Key Lab. of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, 300354, PR China.
| |
Collapse
|
8
|
Jia L, Jiang B, Huang F, Hu X. Nitrogen removal mechanism and microbial community changes of bioaugmentation subsurface wastewater infiltration system. BIORESOURCE TECHNOLOGY 2019; 294:122140. [PMID: 31557654 DOI: 10.1016/j.biortech.2019.122140] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2019] [Revised: 09/05/2019] [Accepted: 09/08/2019] [Indexed: 06/10/2023]
Abstract
Limited nitrogen removal capacity (mainly nitrate, NO3--N) remains a major challenge for subsurface wastewater infiltration system (SWIS). Two nitrogen-removing strains have been isolated from SWIS and inoculated to SWIS to investigate the effect of bioaugmentation on nitrogen removal performance and mechanism. The results showed bioaugmentation improved the removal efficiencies of NH4+-N from 86.81% to 92.86% and TN from 74.90% to 86.55% and running stability compared to unbioaugmentation SWIS. 16 s rRNA amplicon sequencing results of the bacterial indicated that bioaugmentation altered the microbial community structure especially at 150 cm depth and increased the relative abundance of bacteria associated with nitrogen removal, significantly increasing the abundance of Rhizobiales_Incertae_Sedis and Lachnospiraceae. Furthermore, the relation between internal microbial characteristics and operational factors indicated that Hyphomicrobiaceae and Gemmatimonadaceae were also closely related to nitrogen removal. Predicted function profiles revealed that bioaugmentation enhanced the activity of nitrogen removal enzymes (Hao, NorBC, NasAB, NarGHI, NirBD and NosZ).
Collapse
Affiliation(s)
- Liping Jia
- College of Resource and Civil Engineering, Northeastern University, Shenyang 110819, China
| | - Binhui Jiang
- College of Resource and Civil Engineering, Northeastern University, Shenyang 110819, China
| | - Fei Huang
- College of Resource and Civil Engineering, Northeastern University, Shenyang 110819, China
| | - Xiaomin Hu
- College of Resource and Civil Engineering, Northeastern University, Shenyang 110819, China.
| |
Collapse
|
9
|
Zhao ZQ, Shen XL, Zheng TC, Lv L, Su Y, Ghulam A. Aerobic degradation of 2- and 3-fluoroaniline in mixed culture systems and microbial community analysis. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART A, TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING 2019; 55:305-317. [PMID: 31707907 DOI: 10.1080/10934529.2019.1688044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 10/24/2019] [Accepted: 10/25/2019] [Indexed: 06/10/2023]
Abstract
Among three monofluoroanilines, 2-fluoroaniline (2-FA) and 3-fluoroaniline (3-FA) exhibit relatively poor biodegradability. This work examined their degradation characteristics in a mixed culture system and also analyzed the microorganism community. After acclimation for 58 d and 43 d, the high removal efficiency of 100% of 2-FA and 95.3% of 3-FA was obtained by adding 25 mg L-1 of 2-FA or 3-FA to the two reactors, respectively. In addition, the high defluorination rates of 2-FA and 3-FA were observed to be 87.0% and 89.3%, respectively. The degradation kinetics showed that the maximum specific degradation rates of 2-FA and 3-FA were (21.23 ± 0.91) mg FA (g•VSS·h)-1, and (11.75 ± 0.99) mg FA (g•VSS·h)-1, respectively. PCR-DGGE analysis revealed that the unique bacteria degrading 2-FA were mainly composed of six genera (Novosphingobium, Bradyrhizobium, Aquaspirillum, Aminobacter, Ochrobactrum, and Labrys), and five genera that degraded 3-FA (Ochrobactrum, Aquaspirillum, Lachnobacterium, Bradyrhizobium, and Variovorax). Analysis of the key catabolic enzyme activities indicated that the simultaneous hydroxylation and dehalogenation were involved in monooxygenase elimination of 2-FA and conversion of 3-FA to 4-fluorocatechol by dioxygenase, indicating that enriched mixed cultures were effective to metabolize 2-FA or 3-FA by unconventional pathways to prevent the accumulation of toxic metabolites.
Collapse
Affiliation(s)
- Zhi-Qing Zhao
- College of Chemical & Material Engineering, Quzhou University, Quzhou, P.R. China
- College of Environment & Resource Sciences, Zhejiang University, Hangzhou, P.R. China
| | - Xiao-Li Shen
- College of Chemical & Material Engineering, Quzhou University, Quzhou, P.R. China
| | - Tu-Cai Zheng
- College of Chemical & Material Engineering, Quzhou University, Quzhou, P.R. China
| | - Liang Lv
- College of Chemical & Material Engineering, Quzhou University, Quzhou, P.R. China
| | - Yao Su
- Department of Agroenvironmental Engineering, Environmental Resources and Soil Fertilizer Research Institute, Zhejiang Academy of Agricultural Sciences, Hangzhou, China
| | - Abbas Ghulam
- Department of Chemical Engineering, University of Gujrat, Gujrat, Pakistan
| |
Collapse
|