1
|
Improving the efficiency in the detection of gamma activities in environmental soil samples: influence of the granulometry and soil density. J Radioanal Nucl Chem 2019. [DOI: 10.1007/s10967-019-06643-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
2
|
Cebastien Joel GS, Maurice NM, Eric Jilbert NM, Ousmanou M, David S. Monte Carlo method for gamma spectrometry based on GEANT4 toolkit: Efficiency calibration of BE6530 detector. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY 2018; 189:109-119. [PMID: 29653355 DOI: 10.1016/j.jenvrad.2018.03.015] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2017] [Revised: 03/06/2018] [Accepted: 03/29/2018] [Indexed: 06/08/2023]
Abstract
The combination of gamma-ray spectrometry, the development of related Monte Carlo method and the GEANT4 (GEometry ANd Tracking) toolkit have been developed for gamma spectrometry simulation. The main objective was to validate simulation models of broad energy germanium (BEGe) detector geometry built in our laboratory (BE6530 model). Monte Carlo simulation of the geometry of BE6530 detector for efficiency calibration was carried out with GEANT4 toolkit. The simulated efficiencies curves using MC were compared with experimental results. Measurement uncertainties for both simulation and experimental estimations of the efficiency were assessed in order to see whether the consequences of the realistic measurement fall inside adequate cut-off points. The validation of the simulation was carried out by experimentally estimating the activity concentration in a reference sample and the comparison showed good correlation between experimental and simulation. Therefore, from the outcomes of this study, it can be concluded that Monte-Carlo simulation is a helpful, reasonable option that additionally gives more prominent adaptability, greater flexibility, precision and accuracy, and gained time when determining the detector response and efficiency in routine of environmental radioactivity monitoring.
Collapse
Affiliation(s)
- Guembou Shouop Cebastien Joel
- Atomic and Nuclear Spectroscopy, Archeometry, University of Liège, Bat. B15 Sart Tilman, 4000, Liege 1, Belgium; Fundamental Physics Laboratory, Mathematics, Applied Computer Sciences and Fundamental Physics, University of Douala, P.O.Box 24157 Douala, Cameroon; National Radiation Protection Agency, P.O. Box 33732, Yaounde, Cameroon.
| | - Ndontchueng Moyo Maurice
- National Radiation Protection Agency, P.O. Box 33732, Yaounde, Cameroon; Department of Physics, Faculty of Science, University of Douala, P.O. Box 24157, Douala, Cameroon
| | - Nguelem Mekongtso Eric Jilbert
- Fundamental Physics Laboratory, Mathematics, Applied Computer Sciences and Fundamental Physics, University of Douala, P.O.Box 24157 Douala, Cameroon; National Radiation Protection Agency, P.O. Box 33732, Yaounde, Cameroon
| | - Motapon Ousmanou
- Department of Physics, Faculty of Science, University of Douala, P.O. Box 24157, Douala, Cameroon
| | - Strivay David
- Atomic and Nuclear Spectroscopy, Archeometry, University of Liège, Bat. B15 Sart Tilman, 4000, Liege 1, Belgium
| |
Collapse
|