1
|
Carino D, Zancanaro E, Lapenna E, Ruggeri S, Denti P, Iaci G, Buzzatti N, Calabrese MC, Nascimbene S, Sala A, Castiglioni A, Alfieri O, De Bonis M. Long-term results of tricuspid annuloplasty with 3-dimensional-shaped rings: effective and durable! Eur J Cardiothorac Surg 2021; 60:115-121. [PMID: 33693644 DOI: 10.1093/ejcts/ezab111] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 12/23/2020] [Accepted: 01/08/2021] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES 3-Dimensional (3D)-shaped rings are largely adopted for tricuspid annuloplasty, but evidence about their long-term results is scanty. The goal of this study was to analyse the long-term results of tricuspid annuloplasty with 3D-shaped rings. MATERIALS AND METHODS A retrospective review of our prospectively maintained database was carried out to identify all patients who underwent tricuspid valve repair with 3D-shaped rings between January 2011 and December 2014. Kaplan-Meier methods were used to analyse long-term survival. Cumulative incidence function using death as the competitive outcome was used to estimate cardiac death. RESULTS A total of 168 patients were identified. The median age was 66 years. Eighty-two patients (49%) were in advanced New York Heart Association functional class III-IV. Atrial fibrillation (AF) was present in 101 (60%); the median ejection fraction was 60%. In 82 (49%) patients, a Medtronic 3D Contour annuloplasty ring was employed; in the remaining 86 (51%) patients, an Edwards MC3 ring was used. Cumulative incidence function of cardiac death, with non-cardiac death as a competing risk, was 1.9 ± 1.1%, 95% confidence interval (CI) (0.51-4.95) at 7 years. The cumulative incidence function of recurrence of tricuspid regurgitation (TR) ≥2+ at 7 years was 14 ± 3.17%, 95% CI (8.49-20.82). Recurrence of TR ≥2+ at 7 years was not significantly different between the Medtronic 3D Contour and the Edwards MC3 rings (P = 0.3). AF was identified as the only independent predictor of recurrence of TR ≥2+. CONCLUSIONS 3D-shaped rings are effective and durable. TR recurrence was relatively low at 7 years and usually moderate (2+/4+) without a significant difference between the 2 types of rings. The role of AF as a predictor of TR recurrence was confirmed.
Collapse
Affiliation(s)
- Davide Carino
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Edoardo Zancanaro
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Elisabetta Lapenna
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Stefania Ruggeri
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Paolo Denti
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Giuseppe Iaci
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Nicola Buzzatti
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Maria Chiara Calabrese
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Simona Nascimbene
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Alessandra Sala
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Alessandro Castiglioni
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Ottavio Alfieri
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Michele De Bonis
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| |
Collapse
|
2
|
Nosair A, Elkahely M, Nasr S, Alkady H. Tricuspid three-dimensional ring versus fashioned flexible band annuloplasty in management of functional tricuspid valve regurge: comparative long term study. THE CARDIOTHORACIC SURGEON 2020. [DOI: 10.1186/s43057-020-00023-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Functional tricuspid valve regurgitation due to left sided valve lesions remains a common finding. Nowadays, different types of three-dimensional rings and flexible bands are considered to be the gold standard techniques for repair of such functional regurgitation. Our study aimed for long-term comparison of the durability and effectiveness of those techniques.
Results
The data of 170 adult patients with moderate or more functional tricuspid regurgitation secondary to mitral stenosis or regurgitation receiving tricuspid valve repair using either rigid 3D rings (contour 3D or MC3 ring) or prosthetic fashioned bands (Dacron or PTFE) and mitral valve surgery between March 2013 and September 2018 were collected and analysed. Patients were classified in two matched groups: ring group (group A) consisting of 90 cases and band group (group B) consisting of 80 cases. follow-up period ranged from 55.2 to 78 months (mean 67.2 ± 10.8), during this period New York heart association for dyspnea functional class evaluation and full echocardiographic assessment were done and was scheduled as following: before hospital discharge, after 6 months of surgery and finally, every 2 years. In-hospital mortality was 1(1.1%) and 2 (2.5%) with p value 0.49 after ring or band annuloplasty, respectively. No significant differences in both groups regarding hospital mortality and morbidities. There was statistically significant decrease in NYHA class, degree of TR, and PASP within the 2 groups postoperatively with p value of 0.03, 0.04, and 0.033, respectively, with no statistically significant difference between both groups (p value > 0.05). There was statistically significant difference in the freedom from recurrent TR and need for reoperation during the follow-up period between both groups with lower recurrence and reoperation rates in group A, (p value 0.03 and 0.001, respectively).
Conclusion
Tricuspid valve repair with different annuloplasty rigid three dimensional rings or fashioned flexible bands for functional tricuspid regurgitation offers good long-term outcome. Yet, the rigid rings maintain their benefits on the rate of recurrent TR and the need for reoperation.
Collapse
|