1
|
Hosseini RS, Ebrahimi PS, Shokrani A. Diagnostic value of enhanced-contrast ultrasound for cesarean scar pregnancy: A systematic review. Eur J Obstet Gynecol Reprod Biol 2024; 293:119-124. [PMID: 38145593 DOI: 10.1016/j.ejogrb.2023.12.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 12/13/2023] [Accepted: 12/17/2023] [Indexed: 12/27/2023]
Abstract
BACKGROUND Cesarean scar pregnancy, an uncommon ectopic pregnancy in which the embryo is implanted in the cesarean scar, poses significant risks without prompt diagnosis and treatment. Its prevalence has risen alongside increased cesarean section rates. Despite various treatment approaches, consensus remains elusive. Ultrasonography, particularly contrast-enhanced ultrasonography, shows promise in cesarean scar pregnancy diagnosis. MAIN BODY This systematic review, following PRISMA guidelines, explores contrast-enhanced ultrasound's diagnostic potential in cesarean scar pregnancy. We searched PubMed, Scopus, Web of Science, and Google Scholar up to August 2023. Selection involved two stages: title/abstract screening and full-text assessment. The included studies investigated contrast-enhanced ultrasound's diagnostic value in cesarean scar pregnancy, provided adequate data, and were peer-reviewed in English. Quality assessment followed the QUADAS-2 criteria. We extracted the diagnostic accuracy metrics: sensitivity, specificity, and accuracy. Out of 193 records, five studies met the inclusion criteria (2016-2020, China). Contrast-enhanced ultrasound displayed sensitivities of 77%-100% and specificities of 95%-100%. Two studies reported accuracy of 96.9%-97.8%. Compared with conventional ultrasound, contrast-enhanced ultrasound exhibited superior sensitivity, specificity, and accuracy. It also outperformed transvaginal ultrasound. CONCLUSION Enhanced-contrast ultrasound holds promise for diagnosing and managing cesarean scar pregnancy by visualizing scar vascularization in real-time, thereby reducing severe complication risks. This review highlights contrast-enhanced ultrasound as a transformative diagnostic tool for cesarean scar pregnancy management, despite existing evidence limitations.
Collapse
Affiliation(s)
- Reza Shah Hosseini
- Istanbul Medipol University, Faculty of Medicine, Medical Student, Istanbul, Turkey.
| | | | - Aniseh Shokrani
- Istanbul Medipol University, Faculty of Medicine, Medical Student, Istanbul, Turkey
| |
Collapse
|
2
|
Sinagra L, Orlandi R, Caspanello T, Troisi A, Iannelli NM, Vallesi E, Pettina G, Bargellini P, De Majo M, Boiti C, Cristarella S, Quartuccio M, Polisca A. Contrast-Enhanced Ultrasonography (CEUS) in Imaging of the Reproductive System in Dogs: A Literature Review. Animals (Basel) 2023; 13:ani13101615. [PMID: 37238045 DOI: 10.3390/ani13101615] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 04/26/2023] [Accepted: 05/09/2023] [Indexed: 05/28/2023] Open
Abstract
The use of contrast-enhanced ultrasound (CEUS) has been widely reported for reproductive imaging in humans and animals. This review aims to analyze the utility of CEUS in characterizing canine reproductive physiology and pathologies. In September 2022, a search for articles about CEUS in canine testicles, prostate, uterus, placenta, and mammary glands was conducted on PubMed and Scopus from 1990 to 2022, showing 36 total results. CEUS differentiated testicular abnormalities and neoplastic lesions, but it could not characterize tumors. In prostatic diseases, CEUS in dogs was widely studied in animal models for prostatic cancer treatment. In veterinary medicine, this diagnostic tool could distinguish prostatic adenocarcinomas. In ovaries, CEUS differentiated the follicular phases. In CEH-pyometra syndrome, it showed a different enhancement between endometrium and cysts, and highlighted angiogenesis. CEUS was shown to be safe in pregnant dogs and was able to assess normal and abnormal fetal-maternal blood flow and placental dysfunction. In normal mammary glands, CEUS showed vascularization only in diestrus, with differences between mammary glands. CEUS was not specific for neoplastic versus non-neoplastic masses and for benign tumors, except for complex carcinomas and neoplastic vascularization. Works on CEUS showed its usefulness in a wide spectrum of pathologies of this non-invasive, reliable diagnostic procedure.
Collapse
Affiliation(s)
- Letizia Sinagra
- Department of Veterinary Sciences, University of Messina, Viale Palatucci, 13, 98168 Messina, Italy
| | - Riccardo Orlandi
- Anicura Tyrus Clinica Veterinaria, Via Bartocci 1G, 05100 Terni, Italy
| | - Tiziana Caspanello
- Department of Veterinary Sciences, University of Messina, Viale Palatucci, 13, 98168 Messina, Italy
| | - Alessandro Troisi
- School of Biosciences and Veterinary Medicine, University of Camerino, Via Circonvallazione 93/95, 62024 Macerata, Italy
| | - Nicola Maria Iannelli
- Department of Veterinary Sciences, University of Messina, Viale Palatucci, 13, 98168 Messina, Italy
- Clinica Veterinaria Camagna-VetPartners, Via Fortunato Licandro 13, 89124 Reggio di Calabria, Italy
| | - Emanuela Vallesi
- Anicura Tyrus Clinica Veterinaria, Via Bartocci 1G, 05100 Terni, Italy
- Anicura CMV Clinica Veterinaria, Via G.B. Aguggiari 162, 21100 Varese, Italy
| | - Giorgia Pettina
- Department of Veterinary Sciences, University of Messina, Viale Palatucci, 13, 98168 Messina, Italy
| | - Paolo Bargellini
- Anicura Tyrus Clinica Veterinaria, Via Bartocci 1G, 05100 Terni, Italy
| | - Massimo De Majo
- Department of Veterinary Sciences, University of Messina, Viale Palatucci, 13, 98168 Messina, Italy
| | - Cristiano Boiti
- Tyrus Science Foundation, Via Bartocci 1G, 05100 Terni, Italy
| | - Santo Cristarella
- Department of Veterinary Sciences, University of Messina, Viale Palatucci, 13, 98168 Messina, Italy
| | - Marco Quartuccio
- Department of Veterinary Sciences, University of Messina, Viale Palatucci, 13, 98168 Messina, Italy
| | - Angela Polisca
- Department of Veterinary Medicine, University of Perugia, Via San Costanzo 4, 06126 Perugia, Italy
| |
Collapse
|
3
|
Canejo-Teixeira R, Lima A, Santana A. Applications of Contrast-Enhanced Ultrasound in Splenic Studies of Dogs and Cats. Animals (Basel) 2022; 12:ani12162104. [PMID: 36009694 PMCID: PMC9404716 DOI: 10.3390/ani12162104] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 07/29/2022] [Accepted: 08/11/2022] [Indexed: 11/25/2022] Open
Abstract
Simple Summary Contrast-enhanced ultrasound (CEUS) is a noninvasive imaging technique that has become a reliable tool for identifying and monitoring lesions in both human and animals. In the last decade, its use in veterinary diagnostic imaging has gained increasing importance, and it can be reliable in everyday clinical practice. However, there is a lack of reviews describing existing CEUS results in the study of splenic lesions, which is of particular importance in dogs and cats. This information is important for validating its efficacy, to facilitate decision making related to sampling procedures and diagnosis, or even as a means to select CEUS as an alternative diagnostic tool in specific cases. Our goal was to review the existing studies of CEUS applications for splenic ultrasound studies in cats and dogs, present these results in a systematic manner, and combine this information into practical guidelines that can be used to help diagnosis and interpretation in both clinical cases and research. Abstract Contrast-enhanced ultrasound (CEUS) is an emerging technology in veterinary medicine involving the administration of intravenous contrast agents, and it is increasingly recognized for its high potential as a diagnostic imaging tool for small animals. This exam is easy and quick to perform, safe and reliable, and allows for the differentiation of lesions. It permits the identification of lesions that may require more invasive procedures, from those that can be safely dismissed to those that can be followed-up with ultrasound imaging. Although it has been extensively reviewed for use in human medicine, there is an overall lack of information about the application of this technique for cats and dogs, particularly in splenic studies, which can be particularly important for small animals. The present review describes and summarizes the CEUS applications used for splenic analysis in cats and dogs, providing a basic overview of CEUS technology with examples of common and uncommon features of focal splenic lesions. It also systematically gathers the results obtained for benign and malignant splenic lesions described in the literature, whilst providing guidelines for their interpretation. Furthermore, it presents the advantages of using CEUS for splenic analysis in cats and dogs and the main factors that may influence the quality of the imaging and the accuracy of the diagnosis. This type of knowledge can be used to provide a framework to help veterinarians make informed decisions regarding the use of this emerging technique for splenic lesions, guiding their interpretation of CEUS findings in the splenic ultrasounds of cats and dogs.
Collapse
Affiliation(s)
- Rute Canejo-Teixeira
- Faculty of Veterinary Medicine, Lusófona University, 1749-024 Lisbon, Portugal
- Veterinary Teaching Hospital (CA), Faculty of Veterinary Medicine, Lusófona University, 1749-024 Lisbon, Portugal
- Correspondence: (R.C.-T.); (A.L.)
| | - Ana Lima
- Faculty of Veterinary Medicine, Lusófona University, 1749-024 Lisbon, Portugal
- Correspondence: (R.C.-T.); (A.L.)
| | - Ana Santana
- Faculty of Veterinary Medicine, Lusófona University, 1749-024 Lisbon, Portugal
- Veterinary Teaching Hospital (CA), Faculty of Veterinary Medicine, Lusófona University, 1749-024 Lisbon, Portugal
- CECAV-Animal and Veterinary Research Center, Universidade de Trás os Montes e Alto Douro, 5000-801 Vila Real, Portugal
- AL4AnimalS-Associate Laboratory for Animal and Veterinary Sciences, Universidade de Trás os Montes e Alto Douro, 5000-801 Vila Real, Portugal
| |
Collapse
|
4
|
Silva P, Maronezi MC, Padilha-Nakaghi LC, Gasser B, Pavan L, Nogueira Aires LP, Russo M, Spada S, Ramirez Uscategui RA, Moraes PC, Rossi Feliciano MA. Contrast-enhanced ultrasound evaluation of placental perfusion in brachicephalic bitches. Theriogenology 2021; 173:230-240. [PMID: 34399387 DOI: 10.1016/j.theriogenology.2021.08.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 08/06/2021] [Accepted: 08/07/2021] [Indexed: 10/20/2022]
Abstract
The present study aimed to investigate placental hemodynamics to determine quantitative and qualitative parameters for pregnant brachycephalic bitches as well as describe placental vascularization and perfusion in females with fetal abnormalities close to delivery. Forty-four healthy fetuses from 22 brachycephalic bitches and 9 fetuses with gestational abnormalities (anasarca and hydrocephalus) from 8 brachycephalic bitches were evaluated. All female dogs were artificially inseminated intravaginally and underwent cesarean section at the end of gestation. Pregnancy diagnosis was made on the 25th day and experimental evaluations were performed on Days 25 (M1), 45 (M2), and 58 (M3) of gestation in normal pregnancies. Fetuses with gestational abnormalities were evaluated at the last time point. Biometric values of the fetuses were determined by B-mode and vascular indices by Doppler fluxometry of the umbilical artery, whereas qualitative assessment of contrast filling and quantitative parameters of placental perfusion were performed using CEUS. Parameter comparisons among the examined fetuses (normal and abnormal) and between the moments (M1, M2, and M3) were performed by Student's t-test and ANOVA tests, and then correlated using the Spearman test. In healthy fetuses, systolic and diastolic velocities as well as the time averages of minimum and maximum velocities increased significantly from M2 to M3 (P < 0.05), whereas the pulsatility index (P < 0.043) and vascular resistance (P < 0.001) decreased. Contrast distribution was always homogeneous in placental tissues and CEUS filling parameters remained constant during the evaluated periods (P < 0.05). In fetuses with hydrops, Doppler values were similar to those obtained in healthy subjects (P > 0.05), but CEUS evaluation demonstrated a heterogeneous distribution with lower intensity of placental tissue filling and a delay in perfusion time (P < 0.05) with a diagnostic accuracy of 75%. The association of dopplerfluxometry and CEUS allowed evaluation of qualitative and quantitative parameters of physiological pregnancy hemodynamics in all gestational thirds without evidence of significant changes in the physiology of the maternal-fetal binomial, and CEUS was shown to be applicable in the detection of failures in placental vascular filling (tissue dysfunction) in fetuses with anasarca and hydrocephaly.
Collapse
Affiliation(s)
- Priscila Silva
- School of Agricultural and Veterinarian Sciences, São Paulo State University (Unesp), Jaboticabal, São Paulo, Brazil
| | - Marjury Cristina Maronezi
- School of Agricultural and Veterinarian Sciences, São Paulo State University (Unesp), Jaboticabal, São Paulo, Brazil
| | | | - Beatriz Gasser
- School of Agricultural and Veterinarian Sciences, São Paulo State University (Unesp), Jaboticabal, São Paulo, Brazil
| | | | - Luiz Paulo Nogueira Aires
- School of Agricultural and Veterinarian Sciences, São Paulo State University (Unesp), Jaboticabal, São Paulo, Brazil
| | - Marco Russo
- Department of Veterinary Medicine and Animal Sciences University of Naples "Federico II", Italy
| | - Stefano Spada
- Department of Veterinary Medicine and Animal Sciences University of Naples "Federico II", Italy
| | - Ricardo Andrés Ramirez Uscategui
- Institute of Agricultural Sciences, Federal University of the Jequitinhonha and Mucuri Valleys (UFVJM), Unaí, Minas Gerais, Brazil
| | - Paola Castro Moraes
- School of Agricultural and Veterinarian Sciences, São Paulo State University (Unesp), Jaboticabal, São Paulo, Brazil
| | - Marcus Antônio Rossi Feliciano
- School of Agricultural and Veterinarian Sciences, São Paulo State University (Unesp), Jaboticabal, São Paulo, Brazil; Diagnostic Imaging Service, Department of Large Animal Clinic, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil.
| |
Collapse
|
5
|
Sarli G, Castagnetti C, Bianco C, Ballotta G, Tura G, Caporaletti M, Cunto M, Avallone G, Benazzi C, Ostanello F, Zambelli D. Canine Placenta Histological Findings and Microvascular Density: The Histological Basis of a Negative Neonatal Outcome? ANIMALS : AN OPEN ACCESS JOURNAL FROM MDPI 2021; 11:ani11051418. [PMID: 34063427 PMCID: PMC8157207 DOI: 10.3390/ani11051418] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Revised: 05/07/2021] [Accepted: 05/12/2021] [Indexed: 11/16/2022]
Abstract
Simple Summary Accurate examination of the placenta, mainly by gross inspection rather than by histology, is common in clinical practice in some species, for example, in horses, but not carried out routinely in dogs. Placenta alterations in the mare can indicate malfunction, and data exist that intrauterine fetal nutrition influences both perinatal health, but also performances in adult life. Often placenta lesions are not easily appreciable on macroscopical examination, and histology is the best way to assess damage associated with sick newborns. The results of this paper underline the association between placenta injuries and outcome conditions in puppies and confirm, also in dogs, histological placenta investigation as a useful adjunctive tool in the evaluation of the newborn’s health and prognosis. Abstract Placenta is essential for the development of the fetus, and its impaired function can lead to a negative outcome (i.e., neonatal mortality). In dogs, investigations on placenta histology and neonatal outcome in healthy bitches are lacking, and a contribution is provided in this study to emphasize the use of placenta histology in practice. Fifty-one placentas from 11 litters were collected during cesarean section, classified according to the litter size (large (L) or small (S)) and the outcome, this latter as healthy (Group 1) or dead within 7 days (Group 2). The placenta/puppy weight ratio (PPR) was calculated, and specimens were formalin-fixed and paraffin-wax embedded, and on the resulting histological slides, capillary density (CD) was quantified. Among necrosis, calcification, and intravascular leucocytes, only the presence of multifocal-confluent necrosis (significantly more frequent in Group 2) was associated with a higher risk of death within 7 days (odds ratio = 30.7). Mixed logistic regression ruled out the effect on death both of a bitch and cesarean type (programmed vs. emergency). PPR and CD values were associated with litter size; large litters had lower PPR (p < 0.01) and higher CD (p < 0.05) than small litters. The relationship between PPR and CD was negative and significant (p < 0.01). Necrosis was a frequent finding in canine placentas, but only when multifocal-confluent was it associated with a poor outcome. The litter size influenced PPR (lower in L) and CD (higher in L), and this is likely due to the plasticity of placenta adaptation.
Collapse
Affiliation(s)
- Giuseppe Sarli
- Department of Veterinary Medical Sciences, University of Bologna, Via Tolara di Sopra 50, Ozzano dell’Emilia, 40064 Bologna, Italy; (G.S.); (C.C.); (C.B.); (G.B.); (G.T.); (G.A.); (C.B.); (F.O.); (D.Z.)
| | - Carolina Castagnetti
- Department of Veterinary Medical Sciences, University of Bologna, Via Tolara di Sopra 50, Ozzano dell’Emilia, 40064 Bologna, Italy; (G.S.); (C.C.); (C.B.); (G.B.); (G.T.); (G.A.); (C.B.); (F.O.); (D.Z.)
- Health Science and Technologies Interdepartmental Center for Industrial Research (HST-ICIR), University of Bologna, Via Tolara di Sopra 41/E, Ozzano dell’Emilia, 40064 Bologna, Italy
| | - Carlo Bianco
- Department of Veterinary Medical Sciences, University of Bologna, Via Tolara di Sopra 50, Ozzano dell’Emilia, 40064 Bologna, Italy; (G.S.); (C.C.); (C.B.); (G.B.); (G.T.); (G.A.); (C.B.); (F.O.); (D.Z.)
| | - Giulia Ballotta
- Department of Veterinary Medical Sciences, University of Bologna, Via Tolara di Sopra 50, Ozzano dell’Emilia, 40064 Bologna, Italy; (G.S.); (C.C.); (C.B.); (G.B.); (G.T.); (G.A.); (C.B.); (F.O.); (D.Z.)
| | - Giorgia Tura
- Department of Veterinary Medical Sciences, University of Bologna, Via Tolara di Sopra 50, Ozzano dell’Emilia, 40064 Bologna, Italy; (G.S.); (C.C.); (C.B.); (G.B.); (G.T.); (G.A.); (C.B.); (F.O.); (D.Z.)
| | | | - Marco Cunto
- Department of Veterinary Medical Sciences, University of Bologna, Via Tolara di Sopra 50, Ozzano dell’Emilia, 40064 Bologna, Italy; (G.S.); (C.C.); (C.B.); (G.B.); (G.T.); (G.A.); (C.B.); (F.O.); (D.Z.)
- Correspondence: ; Tel.: +39-05-1209-7569
| | - Giancarlo Avallone
- Department of Veterinary Medical Sciences, University of Bologna, Via Tolara di Sopra 50, Ozzano dell’Emilia, 40064 Bologna, Italy; (G.S.); (C.C.); (C.B.); (G.B.); (G.T.); (G.A.); (C.B.); (F.O.); (D.Z.)
| | - Cinzia Benazzi
- Department of Veterinary Medical Sciences, University of Bologna, Via Tolara di Sopra 50, Ozzano dell’Emilia, 40064 Bologna, Italy; (G.S.); (C.C.); (C.B.); (G.B.); (G.T.); (G.A.); (C.B.); (F.O.); (D.Z.)
| | - Fabio Ostanello
- Department of Veterinary Medical Sciences, University of Bologna, Via Tolara di Sopra 50, Ozzano dell’Emilia, 40064 Bologna, Italy; (G.S.); (C.C.); (C.B.); (G.B.); (G.T.); (G.A.); (C.B.); (F.O.); (D.Z.)
| | - Daniele Zambelli
- Department of Veterinary Medical Sciences, University of Bologna, Via Tolara di Sopra 50, Ozzano dell’Emilia, 40064 Bologna, Italy; (G.S.); (C.C.); (C.B.); (G.B.); (G.T.); (G.A.); (C.B.); (F.O.); (D.Z.)
| |
Collapse
|
6
|
Liu D, Gu X, Liu F, Shi F, Yang M. Contrast-enhanced ultrasound in uterine artery embolization treatment of cesarean scar pregnancy. J Int Med Res 2021; 48:300060520980217. [PMID: 33353451 PMCID: PMC7768854 DOI: 10.1177/0300060520980217] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
Objective The current study aimed to investigate the application of contrast-enhanced ultrasound (CEUS) in diagnosis and treatment of cesarean scar pregnancy (CSP). Methods A retrospective study was performed in 35 patients with clinically suspected CSP who requested termination of pregnancy and underwent contrast-enhanced ultrasound (CEUS). The patients were classified into two groups on the basis of whether they received uterine artery embolization (UAE). The CEUS characteristics of the two groups were reviewed. Results CEUS features of CSP were early enhancement of the cesarean scar and continuous infusion of contrast agent between the gestational sac and cesarean scar. Myometrial thickness in the cesarean scar was thinner in the UAE group than in the non-UAE group by CEUS and transvaginal ultrasound. Myometrial thickness measured by CEUS was thinner than that measured by transvaginal ultrasound in both groups. The parameters of the time-intensity curve in the UAE group were characterized by a faster arrival time, shorter time to peak, higher peak intensity, and greater enhancement rate compared with the non-UAE group. Conclusions CEUS may be a novel supplementary method to diagnose and assess CSP, and to help evaluate whether UAE is required.
Collapse
Affiliation(s)
- Dongmei Liu
- Department of Ultrasound, Beijing Shijitan Hospital, Capital Medical University, Beijing, China
| | - Xiaoning Gu
- Department of Ultrasound, Beijing Shijitan Hospital, Capital Medical University, Beijing, China
| | - Fang Liu
- Department of Ultrasound, Beijing Shijitan Hospital, Capital Medical University, Beijing, China
| | - Fuwen Shi
- Department of Ultrasound, Beijing Shijitan Hospital, Capital Medical University, Beijing, China
| | - Min Yang
- Department of Ultrasound, Beijing Shijitan Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
7
|
Ogden NKE, Cullen MD, Stack JD. Assessment of intrasynovial injection in horses by contrast-enhanced ultrasonography using air bubbles created by agitation of solution. Equine Vet J 2020; 53:1159-1168. [PMID: 33222248 DOI: 10.1111/evj.13388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Revised: 10/08/2020] [Accepted: 11/12/2020] [Indexed: 11/29/2022]
Abstract
BACKGROUND Accuracy of intrasynovial injections can be challenging to assess in a clinical setting in horses. Contrast-enhanced ultrasonography (CEUS) using injectate agitated with air has been used to determine the success rates of synovial injections in human rheumatology. OBJECTIVES To assess the diagnostic sensitivity and specificity of CEUS and to describe its clinical use. STUDY DESIGNS Cadaveric study followed by a prospective descriptive observational study. METHODS Part 1: CEUS was performed following injection of agitated methylene-blue solution targeting 13 different anatomical synovial structures from three equine cadavers. Contrast was seen as hyperechoic dots, patches or lines on ultrasonography. CEUS was classified as positive if contrast was considered to be intrasynovial and negative if contrast was considered to be extrasynovial. A second synoviocentesis was performed to determine if the injection was intrasynovial based on the presence or absence of methylene-blue. Estimates of sensitivity and specificity were calculated. Part 2: CEUS was performed following injection of agitated solutions targeting synovial structures as part of routine investigation and treatment of clinical cases. RESULTS Part 1: CEUS was correctly classified as positive or negative in all intrasynovial and extrasynovial injections respectively. The sensitivity estimate was 100% (CI 93%-100%) and the specificity estimates was 100% (CI 16%-100%). Part 2: The technique was used safely for 26 injections (14 horses; 19 different synovial structures) administered to localise or treat lameness. Traumatic intersynovial communications or synovial membrane defects were identified using CEUS in 3 horses. MAIN LIMITATIONS The low number of extrasynovial injections in Part 1 resulted in an imprecise specificity estimate. CONCLUSIONS In horses, CEUS performed following intended intrasynovial injection can be useful for identifying unsuccessful injections.
Collapse
Affiliation(s)
- Nadine K E Ogden
- Faculty of Veterinary Science, Leahurst Equine Hospital, University of Liverpool, Neston, UK
| | - Matthew D Cullen
- Faculty of Veterinary Science, Leahurst Equine Hospital, University of Liverpool, Neston, UK
| | - John D Stack
- Faculty of Veterinary Science, Leahurst Equine Hospital, University of Liverpool, Neston, UK
| |
Collapse
|
8
|
Contrast-Enhanced Ultrasound in Cystic Endometrial Hyperplasia-Pyometra Complex in the Bitch: A Preliminary Study. Animals (Basel) 2020; 10:ani10081368. [PMID: 32784584 PMCID: PMC7460530 DOI: 10.3390/ani10081368] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 08/04/2020] [Accepted: 08/04/2020] [Indexed: 12/11/2022] Open
Abstract
Simple Summary In canine cystic endometrial hyperplasia–pyometra (CEH) syndrome, toxic factors and endometrial inflammatory reactions are responsible of increased blood flow and lower vascular resistance in uterine arteries. Color Doppler ultrasound is regarded as an adjunctive tool for quantitative assessment of endometrial vascularization during uterine disorders. The aim of this study was to assess, through contrast-enhanced ultrasound (CEUS) exam, the vascularization in endometrial microvessels in CEH-pyometra in order to evaluate the possibility of application in this syndrome. In twelve female dogs with clinical symptoms related to pyometra, echographic, Color Doppler and CEUS exams were performed. Histopathological examination revealed severe CEH and pyometra, immunohistochemical stain with CD 34 confirmed the presence of angiogenesis. CEUS exam revealed a widespread, intense and rapidly developing homogeneous enhancement of the hyperplastic endometrium with absence of signal only in cystic areas. All parameters of the quantitative analysis were not significantly influenced by region of interest dimension and position. CEUS may improve not invasive evaluations in the CEH-pyometra syndrome and virtually in CEH-mucometra. Abstract In cystic endometrial hyperplasia (CEH)–pyometra syndrome, toxic factors and endometrial remodeling culminate in changes characterized by exudative and degenerative inflammatory reaction. Recent studies on hemodynamic found an increased blood flow and lower vascular resistance in uterine arteries, suggesting color Doppler ultrasound as an adjunctive tool for quantitative assessment of endometrial vascularization during pyometra. The aim of this study was to assess, through contrast-enhanced ultrasound (CEUS) exam, the vascularization in endometrial microvessels in CEH-pyometra in order to evaluate the possibility of application in this syndrome. In twelve female dogs with clinical symptoms related to pyometra, B-mode, color Doppler and CEUS exams were performed. In CEH-pyometra uteri, histopathological examination revealed severe CEH and pyometra, immunohistochemical stain with CD 34 confirmed the presence of angiogenesis. CEUS exams revealed a widespread, intense and rapidly developing homogeneous enhancement of the hyperplastic endometrium, with absence of signal only in cystic areas. All parameters of the quantitative analysis were not significantly influenced by region of interest dimension and position. CEUS has the potential to improve clinical not invasive evaluations in the CEH-pyometra syndrome and virtually in CEH-mucometra.
Collapse
|
9
|
Orlandi R, Vallesi E, Boiti C, Polisca A, Troisi A, Righi C, Bargellini P. Contrast-enhanced ultrasonography of maternal and fetal blood flows in pregnant bitches. Theriogenology 2018; 125:129-134. [PMID: 30414566 DOI: 10.1016/j.theriogenology.2018.10.027] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2018] [Revised: 10/29/2018] [Accepted: 10/29/2018] [Indexed: 12/14/2022]
Abstract
We evaluated the potential usefulness of CEUS to assess fetal-maternal circulation during pregnancy in dogs. Nine bitches were examined at 23, 30, and 45 days of gestation using an ultrasound machine (LOGIQ E9) and SonoVue® contrast media as echo-signal enhancer. Qualitative and quantitative evaluation of contrast enhancement patterns of uterine artery and utero/placental vessels were performed on recorded images. Independently of the gestational periods, the qualitative evaluation showed the initial wash-in phase from the first appearance of the uterine artery to the rapid distribution in embryonic vesicles or placenta to the progressive washout, whilst there was no enhancement of either embryos or fetuses in any bitch. Independent of gestational age, parameters derived from quantitative analysis of time intensity-curves of contrast enhancement (peak intensity, time to peak, rise time, washout) did not vary between proximal placenta, distal placenta, and uterine artery. With the progression of gestation, AUC values did not change in both proximal and distal placenta, but in the uterine artery it was lower (P ≤ 0.05) at day 30 than at day 23 (464.8 ± 16.1 vs.596.4 ± 28.1, respectively). In conclusion, CEUS appears to safely permit evaluation of the maternal and fetal vessels in the first two third of gestation, without any clinically relevant adverse effects. Further studies in a larger number of bitches in different stages of pregnancy are needed to establish standard parameters for normal pregnancies that can be used to detect abnormalities of pregnancy.
Collapse
Affiliation(s)
- Riccardo Orlandi
- Tyrus Veterinary Clinic, Via A. Bartocci 1/G, 05100, Terni (TR), Italy.
| | - Emanuela Vallesi
- Tyrus Veterinary Clinic, Via A. Bartocci 1/G, 05100, Terni (TR), Italy
| | - Cristiano Boiti
- Tyrus Veterinary Clinic, Via A. Bartocci 1/G, 05100, Terni (TR), Italy
| | - Angela Polisca
- Department of Veterinary Medicine, University of Perugia, Via S. Costanzo 4, 06126, Perugia (PG), Italy
| | - Alessandro Troisi
- Department of Veterinary Medicine, University of Perugia, Via S. Costanzo 4, 06126, Perugia (PG), Italy
| | - Cecilia Righi
- Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", Via G. Salvemini 1, 06126, Perugia (PG), Italy
| | - Paolo Bargellini
- Tyrus Veterinary Clinic, Via A. Bartocci 1/G, 05100, Terni (TR), Italy
| |
Collapse
|