1
|
Cheng SH, Lin YT, Lu HT, Tsuei YC, Chu W, Chu WC. The Evolution of Spinal Endoscopy: Design and Image Analysis of a Single-Use Digital Endoscope Versus Traditional Optic Endoscope. Bioengineering (Basel) 2024; 11:99. [PMID: 38275579 PMCID: PMC10813680 DOI: 10.3390/bioengineering11010099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 01/11/2024] [Accepted: 01/17/2024] [Indexed: 01/27/2024] Open
Abstract
Spinal endoscopy has evolved significantly since its inception, offering minimally invasive solutions for various spinal pathologies. This study introduces a promising innovation in spinal endoscopy-a single-use digital endoscope designed to overcome the drawbacks of traditional optic endoscopes. Traditional endoscopes, despite their utility, present challenges such as fragility, complex disinfection processes, weight issues, and susceptibility to mechanical malfunctions. The digital endoscope, with its disposable nature, lighter weight, and improved image quality, aims to enhance surgical procedures and patient safety. The digital endoscope system comprises a 30-degree 1000 × 1000 pixel resolution camera sensor with a 4.3 mm working channel, and LED light sources replacing optical fibers. The all-in-one touch screen tablet serves as the host computer, providing portability and simplified operation. Image comparisons between the digital and optic endoscopes revealed advantages in the form of increased field of view, lesser distortion, greater close-range resolution, and enhanced luminance. The single-use digital endoscope demonstrates great potential for revolutionizing spine endoscopic surgeries, offering convenience, safety, and superior imaging capabilities compared to traditional optic endoscopes.
Collapse
Affiliation(s)
- Shih-Hao Cheng
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
- Department of Orthopedics, Cheng Hsin General Hospital, Taipei 11221, Taiwan
| | - Yen-Tsung Lin
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
| | - Hsin-Tzu Lu
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
| | - Yu-Chuan Tsuei
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
- Department of Orthopedics, Cheng Hsin General Hospital, Taipei 11221, Taiwan
| | - William Chu
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
- Department of Orthopedics, Cheng Hsin General Hospital, Taipei 11221, Taiwan
- School of Nursing, National Taipei University of Nursing and Health Sciences, Taipei 11221, Taiwan
| | - Woei-Chyn Chu
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
| |
Collapse
|
2
|
Hervé RC, Kong MG, Bhatt S, Comoy EE, Deslys JP, Secker TJ, Keevil CW. Evaluation of cold atmospheric plasma for the decontamination of flexible endoscopes. J Hosp Infect 2023; 136:100-109. [PMID: 36965823 DOI: 10.1016/j.jhin.2023.03.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 03/13/2023] [Accepted: 03/15/2023] [Indexed: 03/27/2023]
Abstract
BACKGROUND Despite adherence to standard protocols, residues including live microorganisms may remain on the various surfaces of reprocessed flexible endoscopes. Prions are infectious proteins notoriously difficult to eliminate. AIM We tested the potential of cold atmospheric plasma (CAP) for the decontamination of flexible endoscope various surfaces, measuring total proteins and prion-residual infectivity as an indicator of efficacy. METHODS New PTFE endoscope channels and metal test surfaces spiked with test soil or prion-infected tissues were treated using different CAP-generating prototypes. Surfaces were then examined for the presence of residues using very sensitive fluorescence epi-microscopy. Prion residual infectivity was determined using the wire implant animal model and a new, more sensitive cell infectivity assay. FINDINGS A CAP jet applied perpendicularly at close range on flat test surfaces removed soil within 3 minutes but left microscopic residues and failed to eliminate prion infectivity according to the wire implant animal assay. The longitudinal gas flow from CAP prototypes developed for the treatment of long channels led to the displacement and sedimentation of residual soil towards the distal end, when applied alone. Observations of the plasma inside glass tubes showed temporal and spatial heterogeneity within a limited range. After standard enzymatic manual pre-wash, "CAP-activated" gas effluents prevented prion transmission from treated endoscope channels according to our prion infectivity cell assay. CONCLUSION CAP shows promising results as a final step for surgical surfaces decontamination. Optimising CAP delivery could further enhance CAP efficacy, offering a safe, chemical-free alternative for the reprocessing of all luminal flexible endoscope surfaces.
Collapse
Affiliation(s)
- Rodolphe C Hervé
- Environmental Healthcare Unit, School of Biological Sciences, University of Southampton, Southampton, SO16 7PX, UK.
| | - Michael G Kong
- Center for Bioelectrics, Old Dominion University, Norfolk, Virginia, USA
| | - Sudhir Bhatt
- Center for Bioelectrics, Old Dominion University, Norfolk, Virginia, USA
| | - Emmanuel E Comoy
- Commissariat à l'Energie Atomique et aux Energies Alternatives (CEA), Direction de la Recherche Fondamentale (DRF), Institut François Jacob, SEPIA, Université Paris-Saclay, 18 Route du Panorama, F-92265, Fontenay-aux-Roses, France
| | - Jean-Philippe Deslys
- Commissariat à l'Energie Atomique et aux Energies Alternatives (CEA), Direction de la Recherche Fondamentale (DRF), Institut François Jacob, SEPIA, Université Paris-Saclay, 18 Route du Panorama, F-92265, Fontenay-aux-Roses, France
| | - Thomas J Secker
- Environmental Healthcare Unit, School of Biological Sciences, University of Southampton, Southampton, SO16 7PX, UK
| | - Charles W Keevil
- Environmental Healthcare Unit, School of Biological Sciences, University of Southampton, Southampton, SO16 7PX, UK
| |
Collapse
|
3
|
Ofstead CL, Smart AG, Hopkins KM, Wetzler HP. The utility of lighted magnification and borescopes for visual inspection of flexible endoscopes. Am J Infect Control 2023; 51:2-10. [PMID: 36075293 DOI: 10.1016/j.ajic.2022.08.026] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 08/26/2022] [Accepted: 08/28/2022] [Indexed: 02/05/2023]
Abstract
INTRODUCTION Infections have been linked to damaged or contaminated endoscopes with visible defects. Endoscope processing standards and guidelines state endoscopes should be visually inspected every time they are used. This study evaluated a new visual inspection program using magnification and borescopes in an endoscopy department that had not previously utilized these tools. METHODS Site personnel were given visual inspection tools and training before systematically examining fully processed endoscopes twice during a 2-month period. A risk assessment protocol was used to determine whether endoscopes required recleaning, repair, or other action. Findings were documented using log sheets, photographs, and videotapes. RESULTS Visible damage and residue or debris were observed in 100% of 25 endoscopes at both assessments, and 76% required repair. Defects at baseline included scratches (88%); channel shredding or peeling (80%); adhesive band disintegration (80%); residual soil or debris (white 84%; black 68%; brown 40%; yellow/green 36%; and orange/red 8%); retained fluid (52%); and dents (40%). Findings were similar at follow-up. DISCUSSION/CONCLUSIONS Visual inspection with magnification and borescopes identified actionable defects that could interfere with processing effectiveness in 100% of endoscopes. Infection preventionists have a critical role to play in supporting processing personnel now that standards, guidelines, and manufacturer instructions recommend enhanced visual inspection of every endoscope, every time.
Collapse
|
4
|
Madureira RADS, de Oliveira AC. Cleaning of in-hospital flexible endoscopes: Limitations and challenges. Rev Lat Am Enfermagem 2022; 30:e3684. [PMID: 36287399 PMCID: PMC9580990 DOI: 10.1590/1518-8345.5969.3684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 06/15/2022] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVE to analyze the cleaning process of gastroscopes, colonoscopes and duodenoscopes in eight in-hospital health services. METHOD a cross-sectional study conducted with 22 endoscopes (eight gastroscopes, eight colonoscopes and six duodenoscopes), and microbiological analysis of 60 samples of air/water channels (all endoscopes) and elevator (duodenoscopes), in addition to protein testing. Descriptive statistics with calculation of frequencies and central tendency measures was used in data analysis. RESULTS the processing of 22 endoscopes was monitored with microbiological analysis for 60 channels. In the pre-cleaning procedure, in 82.3% (14/17) of the devices, gauze was used in cleaning the insertion tube. Incomplete immersion of the endoscope in detergent solution occurred in 72.3% (17/22) of the cases, and in 63.6% (14/22) there was no standardization of filling-in of the channels. Friction of the biopsy channel was not performed in 13.6% (3/22) of the devices. In the microbiological analysis, 25% (7/32) of the samples from the stored endoscopes were positive for microbial growth (from 2x101 to 9.5x104 CFU/mL), while after processing, contamination was 32% (9/28). Protein residues in the elevator channel were detected in 33% of duodenoscopes. CONCLUSION the results indicate important gaps in the stages of pre-cleaning and cleaning of endoscopes that, associated with presence of protein residues and growth of microorganisms of epidemiological importance, indicate limitations in safety of the processing procedures, which can compromise the disinfection processes and, consequently, their safe use among patients subjected to such tests.
Collapse
|
5
|
de Almeida MTG, de Almeida BG, Siqueira JPZ, Byzynski Soares G, Sigari Morais V, Mitsue Yasuoka FM, Ghiglieno F. Ultraviolet-C Light-emitting Device Against Microorganisms in Beauty Salons. Pathog Immun 2022; 7:49-59. [PMID: 35795726 PMCID: PMC9249058 DOI: 10.20411/pai.v7i1.497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Accepted: 05/13/2022] [Indexed: 11/23/2022] Open
Abstract
Background Ultraviolet light in the UV-C band is also known as germicidal radiation, and it is widely used for decontamination and disinfection of environments, water, and food. The ultraviolet source transfers electromagnetic energy from a mercury arc lamp to an organism's genetic material. When UV radiation penetrates the cell wall of an organism, it destroys the cell's ability to reproduce, through a physical and not chemical process. Thus, the objective of this study was to evaluate the antimicrobial potential of a new UV-C generating device (Asepsis) against clinically important microorganisms that may be present in beauty centers. Methods We present here a set of tests performed on tools easy to find in beauty salons (hair-brushes, nail pliers, makeup brushes, and, due to the recent COVID-19 pandemic, face mask samples). They were individually contaminated with bacteria (Pseudomonas aeruginosa, Staphylococcus aureus), fungi (Microsporum canis, Trichophyton rubrum, Candida albicans, Malassezia furfur), and the Chikungunya virus. Different times of exposure were evaluated (1, 3, and 5 minutes). Results There was notable reduction in the microbial load in every test, in comparison with control groups. Best results were observed on face mask samples, while the makeup brush showed less reduction, even with longer periods of exposure. Conclusions Beauty salons present a risk of infections due to microbial exposure. The device tested can efficiently inactivate, in a short time, microorganisms contaminating most tools found in this setting. The device also showed promising results against enveloped virus.
Collapse
Affiliation(s)
| | - Bianca Gottardo de Almeida
- Universidade Júlio de Mesquita Filho (UNESP), campus of São José do Rio Preto (Ibilce), São José do Rio Preto, Brazil
| | | | | | | | | | - Filippo Ghiglieno
- Universidade Federal de São Carlos (UFSCar) – Laboratório de Óptica, Laser e Fotônica (OLAF), São Carlos, Brazil
| |
Collapse
|
6
|
Madureira RADS, Oliveira ACD. Limpieza de endoscopios flexibles intrahospitalarios: limitaciones y desafíos. Rev Lat Am Enfermagem 2022. [DOI: 10.1590/1518-8345.5969.3683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Resumen Objetivo: analizar el proceso de limpieza de gastroscopios, colonoscopios y duodenoscopios en ocho servicios de salud intrahospitalarios. Método: estudio transversal con 22 endoscopios, de los cuales ocho eran gastroscopios, ocho colonoscopios y seis duodenoscopios, y análisis microbiológico de 60 muestras de los canales de aire/agua (todos los endoscopios) y elevador (duodenoscopios), además de prueba de proteínas. En el análisis de los datos se utilizó estadística descriptiva, con cálculo de frecuencias y medidas de tendencia central. Resultados: el procesamiento de los 22 endoscopios fue monitoreado con el análisis microbiológico de 60 canales. En la prelimpieza, en el 82,3% (14/17) de los equipos se utilizó gasa para limpiar el tubo de inserción. En el 72,3% (17/22) de los casos la inmersión del endoscopio en solución detergente fue incompleta y en el 63,6% (14/22) no hubo estandarización del llenado de los canales. La fricción del canal de biopsia no se realizó en el 13,6% (3/22) de los equipos. En el análisis microbiológico, el 25% (7/32) de las muestras endoscópicas almacenadas dio positivo para crecimiento microbiano (2x101 a 9,5x104 UFC/ml), mientras que después del procesamiento, la contaminación fue del 32% (9/28). Se detectaron residuos de proteína en el canal elevador en el 33% de los duodenoscopios. Conclusión: los resultados indican que hay importantes lagunas en las etapas de prelimpieza y limpieza de los endoscopios que, junto con la presencia de residuos de proteínas y del crecimiento de microorganismos de importancia epidemiológica, indican limitaciones en la seguridad del procesamiento, que pueden comprometer los procesos de desinfección y, por ende, el uso seguro en los pacientes que se someten a esos procedimientos.
Collapse
|
7
|
Madureira RADS, Oliveira ACD. Limpeza de endoscópios flexíveis intra-hospitalares: limitações e desafios. Rev Lat Am Enfermagem 2022. [DOI: 10.1590/1518-8345.5969.3685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Resumo Objetivo: analisar o processo de limpeza de gastroscópios, colonoscópios e duodenoscópios em oito serviços de saúde intra-hospitalar. Método: estudo transversal com 22 endoscópios, sendo oito gastroscópios, oito colonoscópios e seis duodenoscópios, e análise microbiológica de 60 amostras dos canais de ar/água (todos os endoscópios) e elevador (duodenoscópios), além de teste de proteína. Na análise dos dados, utilizou-se estatística descritiva, com cálculo de frequências e medidas de tendência central. Resultados: o processamento de 22 endoscópios foi acompanhado com análise microbiológica de 60 canais. Na pré-limpeza, em 82,3% (14/17) dos equipamentos, foi utilizada gaze na limpeza do tubo de inserção. A imersão incompleta do endoscópio em solução detergente ocorreu em 72,3% (17/22) dos casos, e em 63,6% (14/22) não havia padronização do preenchimento dos canais. A fricção do canal de biópsia não foi realizada em 13,6% (3/22) dos equipamentos. Na análise microbiológica, 25% (7/32) das amostras dos endoscópios armazenados foram positivas para crescimento microbiano (2x101 a 9,5x104 UFC/mL), enquanto após o processamento, a contaminação foi de 32% (9/28). Resíduos de proteína no canal do elevador foram detectados em 33% dos duodenoscópios. Conclusão: os resultados apontam lacunas importantes nas etapas de pré-limpeza e limpeza dos endoscópios que, associadas à presença de resíduos de proteína e ao crescimento de microrganismo de importância epidemiológica, sinalizam limitações na segurança do processamento, que podem comprometer os processos de desinfecção e consequentemente seu uso seguro entre pacientes submetidos a tais exames.
Collapse
|
8
|
Heuvelmans M, Wunderink HF, van der Mei HC, Monkelbaan JF. A narrative review on current duodenoscope reprocessing techniques and novel developments. Antimicrob Resist Infect Control 2021; 10:171. [PMID: 34949217 PMCID: PMC8697464 DOI: 10.1186/s13756-021-01037-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 11/19/2021] [Indexed: 11/10/2022] Open
Abstract
Duodenoscopy-associated infections occur worldwide despite strict adherence to reprocessing standards. The exact scope of the problem remains unknown because a standardized sampling protocol and uniform sampling techniques are lacking. The currently available multi-society protocol for microbial culturing by the Centers for Disease Control and Prevention, the United States Food and Drug Administration (FDA) and the American Society for Microbiology, published in 2018 is too laborious for broad clinical implementation. A more practical sampling protocol would result in increased accessibility and widespread implementation. This will aid to reduce the prevalence of duodenoscope contamination. To reduce the risk of duodenoscopy-associated pathogen transmission the FDA advised four supplemental reprocessing measures. These measures include double high-level disinfection, microbiological culturing and quarantine, ethylene oxide gas sterilization and liquid chemical sterilization. When the supplemental measures were advised in 2015 data evaluating their efficacy were sparse. Over the past five years data regarding the supplemental measures have become available that place the efficacy of the supplemental measures into context. As expected the advised supplemental measures have resulted in increased costs and reprocessing time. Unfortunately, it has also become clear that the efficacy of the supplemental measures falls short and that duodenoscope contamination remains a problem. There is a lot of research into new reprocessing methods and technical applications trying to solve the problem of duodenoscope contamination. Several promising developments such as single-use duodenoscopes, electrolyzed acidic water, and vaporized hydrogen peroxide plasma are already applied in a clinical setting.
Collapse
Affiliation(s)
- Maarten Heuvelmans
- Department of Medical Microbiology, University Medical Center Utrecht, G04.643, PO box 85500, 3508GA, Utrecht, The Netherlands.
| | - Herman F Wunderink
- Department of Medical Microbiology, University Medical Center Utrecht, G04.643, PO box 85500, 3508GA, Utrecht, The Netherlands
| | - Henny C van der Mei
- Department of Biomedical Engineering, University of Groningen and University Medical Center Groningen, Groningen, The Netherlands
| | - Jan F Monkelbaan
- Department of Gastroenterology and Hepatology, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
9
|
Secker TJ, Leighton TG, Offin DG, Birkin PR, Hervé RC, Keevil CW. A cold water, ultrasonically activated stream efficiently removes proteins and prion-associated amyloid from surgical stainless steel. J Hosp Infect 2020; 106:649-656. [PMID: 32956784 PMCID: PMC7501313 DOI: 10.1016/j.jhin.2020.09.021] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 09/11/2020] [Accepted: 09/11/2020] [Indexed: 11/30/2022]
Abstract
Background Sterile service department decontamination procedures for surgical instruments struggle to demonstrate efficient removal of the hardiest infectious contaminants, such as prion proteins. A recently designed novel system, which uses a low pressure ultrasonically activated, cold water stream, has previously demonstrated efficient hard surface cleaning of several biological contaminants. Aim To test the efficacy of an ultrasonically activated stream for the removal of tissue proteins, including prion-associated amyloid, from surgical stainless steel surfaces. Methods Test surfaces were contaminated with 22L, ME7 or 263K prion-infected brain homogenates. The surfaces were treated with the ultrasonically activated water stream for contact times of 5 and 10 s. Residual proteinaceous and amyloid contamination were quantified using sensitive microscopic analysis, and immunoblotting was used to characterize the eluted prion residues before and after treatment with the ultrasonically activated stream. Findings Efficient removal of the different prion strains from the surgical stainless steel surfaces was observed, and reduced levels of protease-susceptible and -resistant prion protein was detected in recovered supernatant. Conclusion This study demonstrated that an ultrasonically activated stream has the potential to be a cost-effective solution to improve current decontamination practices and has the potential to reduce hospital-acquired infections.
Collapse
Affiliation(s)
- T J Secker
- Environmental Healthcare Unit, School of Biological Sciences, Faculty of Environmental and Life Sciences, University of Southampton, Southampton, UK.
| | - T G Leighton
- Institute of Sound and Vibration Research, Faculty of Engineering and Environment, University of Southampton, Southampton, UK; Sloan Water Technology Ltd, Chilworth, Southampton, UK
| | - D G Offin
- Chemistry, Faculty of Environmental and Life Sciences, University of Southampton, Southampton, UK
| | - P R Birkin
- Chemistry, Faculty of Environmental and Life Sciences, University of Southampton, Southampton, UK
| | - R C Hervé
- Environmental Healthcare Unit, School of Biological Sciences, Faculty of Environmental and Life Sciences, University of Southampton, Southampton, UK
| | - C W Keevil
- Environmental Healthcare Unit, School of Biological Sciences, Faculty of Environmental and Life Sciences, University of Southampton, Southampton, UK
| |
Collapse
|
10
|
Stevenson M, Uttley L, Oakley JE, Carroll C, Chick SE, Wong R. Interventions to reduce the risk of surgically transmitted Creutzfeldt-Jakob disease: a cost-effective modelling review. Health Technol Assess 2020; 24:1-150. [PMID: 32122460 PMCID: PMC7103914 DOI: 10.3310/hta24110] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Creutzfeldt-Jakob disease is a fatal neurological disease caused by abnormal infectious proteins called prions. Prions that are present on surgical instruments cannot be completely deactivated; therefore, patients who are subsequently operated on using these instruments may become infected. This can result in surgically transmitted Creutzfeldt-Jakob disease. OBJECTIVE To update literature reviews, consultation with experts and economic modelling published in 2006, and to provide the cost-effectiveness of strategies to reduce the risk of surgically transmitted Creutzfeldt-Jakob disease. METHODS Eight systematic reviews were undertaken for clinical parameters. One review of cost-effectiveness was undertaken. Electronic databases including MEDLINE and EMBASE were searched from 2005 to 2017. Expert elicitation sessions were undertaken. An advisory committee, convened by the National Institute for Health and Care Excellence to produce guidance, provided an additional source of information. A mathematical model was updated focusing on brain and posterior eye surgery and neuroendoscopy. The model simulated both patients and instrument sets. Assuming that there were potentially 15 cases of surgically transmitted Creutzfeldt-Jakob disease between 2005 and 2018, approximate Bayesian computation was used to obtain samples from the posterior distribution of the model parameters to generate results. Heuristics were used to improve computational efficiency. The modelling conformed to the National Institute for Health and Care Excellence reference case. The strategies evaluated included neither keeping instruments moist nor prohibiting set migration; ensuring that instruments were kept moist; prohibiting instrument migration between sets; and employing single-use instruments. Threshold analyses were undertaken to establish prices at which single-use sets or completely effective decontamination solutions would be cost-effective. RESULTS A total of 169 papers were identified for the clinical review. The evidence from published literature was not deemed sufficiently strong to take precedence over the distributions obtained from expert elicitation. Forty-eight papers were identified in the review of cost-effectiveness. The previous modelling structure was revised to add the possibility of misclassifying surgically transmitted Creutzfeldt-Jakob disease as another neurodegenerative disease, and assuming that all patients were susceptible to infection. Keeping instruments moist was estimated to reduce the risk of surgically transmitted Creutzfeldt-Jakob disease cases and associated costs. Based on probabilistic sensitivity analyses, keeping instruments moist was estimated to on average result in 2.36 (range 0-47) surgically transmitted Creutzfeldt-Jakob disease cases (across England) caused by infection occurring between 2019 and 2023. Prohibiting set migration or employing single-use instruments reduced the estimated risk of surgically transmitted Creutzfeldt-Jakob disease cases further, but at considerable cost. The estimated costs per quality-adjusted life-year gained of these strategies in addition to keeping instruments moist were in excess of £1M. It was estimated that single-use instrument sets (currently £350-500) or completely effective cleaning solutions would need to cost approximately £12 per patient to be cost-effective using a £30,000 per quality-adjusted life-year gained value. LIMITATIONS As no direct published evidence to implicate surgery as a cause of Creutzfeldt-Jakob disease has been found since 2005, the estimations of potential cases from elicitation are still speculative. A particular source of uncertainty was in the number of potential surgically transmitted Creutzfeldt-Jakob disease cases that may have occurred between 2005 and 2018. CONCLUSIONS Keeping instruments moist is estimated to reduce the risk of surgically transmitted Creutzfeldt-Jakob disease cases and associated costs. Further surgical management strategies can reduce the risks of surgically transmitted Creutzfeldt-Jakob disease but have considerable associated costs. STUDY REGISTRATION This study is registered as PROSPERO CRD42017071807. FUNDING This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 24, No. 11. See the NIHR Journals Library website for further project information.
Collapse
Affiliation(s)
- Matt Stevenson
- School of Health and Related Research (ScHARR), University of Sheffield, Sheffield, UK
| | - Lesley Uttley
- School of Health and Related Research (ScHARR), University of Sheffield, Sheffield, UK
| | - Jeremy E Oakley
- School of Mathematics and Statistics, University of Sheffield, Sheffield, UK
| | - Christopher Carroll
- School of Health and Related Research (ScHARR), University of Sheffield, Sheffield, UK
| | | | - Ruth Wong
- School of Health and Related Research (ScHARR), University of Sheffield, Sheffield, UK
| |
Collapse
|
11
|
Abstract
BACKGROUND Anterograde transnasal flexible endoscopy of the pharynx, larynx, and proximal trachea without sedation has been established since the 1990s. Retroflexed endoscopic functional analysis has recently been introduced. OBJECTIVES Adding retroflexed functional endoscopy from the oral cavity up to the duodenum to anterograde diagnostics allows the precise demonstration of how different factors interact in a complex way, e. g., in case of dysphagia or pathological reflux. MATERIALS AND METHODS A 70-cm-long high-definition endoscope without a channel system is equipped with a 200° retroflexed view, a mm-cm scale, and a roller system. The endoscope can be lengthened, stopped, or shortened during the procedure. Standard positions, viewing directions and display details ensure that findings are comparable. Mastication, food transport and digestion are observed in the unsedated patient. RESULTS Depending on indication and symptoms, we defined a diagnostic algorithm including three specific pathways: (1) for conditions that originate in the oral cavity, larynx or pharynx, (2) for suspected reflux disease, or for neurological or neuromuscular disorders of food transport, (3) for duodenogastric, gastroesophageal and esophagopharyngeal reflux, as well for benign or malignant tumors. CONCLUSION The advantages of functional endoscopy have an impact not only on the medical staff and patients. Its precise and participatory approach is relevant to healthcare, enlarges the diagnostic horizon, and forms a basis for interdisciplinary collaboration.
Collapse
|
12
|
Gonzalez JA, Vanzieleghem T, Dumazy A, Meuris C, Mutsers J, Christiaens G, Leclercq P, Loly JP, Louis E, Gast P. On-site comparison of an enzymatic detergent and a non-enzymatic detergent-disinfectant for routine manual cleaning of flexible endoscopes. Endosc Int Open 2019; 7:E412-E420. [PMID: 30931371 PMCID: PMC6428680 DOI: 10.1055/a-0838-4995] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2018] [Accepted: 11/26/2018] [Indexed: 10/27/2022] Open
Abstract
Background and study aims Flexible endoscopes are potential vectors of pathogen transmission to patients that are subjected to cleaning and high-level disinfection after each procedure. Efficient manual cleaning is a prerequisite for effective high-level disinfection. The goal of this study was to demonstrate the impact of the cleaning chemistry in the outcome of the manual cleaning of endoscopes. Materials and methods Twelve endoscopes were included in this study: four colonoscopes, four gastroscopes, two duodenoscopes and two bronchoscopes. This study was designed with two phases; in each of them, the manual cleaning procedure remained identical, but a different detergent was used: a non-enzymatic detergent-disinfectant (NEDD) and an enzymatic detergent (ED). Biopsy and suction channels of endoscopes were sampled using 10 mL of physiological saline at two points: before and after manual cleaning, and adenosine triphosphate (ATP) was measured on each sample. In total, 208 procedures were analyzed for the NEDD phase and 253 for the ED phase. Results For each endoscope type, cleaning endoscopes with ED resulted in larger median decrease in ATP than with NEDD: respectively 99.43 % and 95.95 % for bronchoscopes ( P = 0.0007), 99.28 % and 96.93 % for colonoscopes ( P < 0.0001) and 98.36 % and 95.36 % for gastroscopes ( P < 0.0001). In addition, acceptability rates of endoscopes based on defined post-manual cleaning ATP thresholds (200, 150, 100 or 50 relative light units) for all endoscope types were significantly higher with ED compared to NEDD. Conclusions With all other parameters of manual cleaning remaining unchanged, the enzymatic chemistry of ED provided more consistent and improved cleaning of endoscopes compared to NEDD. Therefore, choice of the detergent for endoscope cleaning has an impact on the outcome of this process.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | - Pierrette Gast
- Gastroenterology Department, University Hospital of Liège, Belgium
| |
Collapse
|
13
|
Johani K, Hu H, Santos L, Schiller S, Deva A, Whiteley G, Almatroudi A, Vickery K. Determination of bacterial species present in biofilm contaminating the channels of clinical endoscopes. Infect Dis Health 2018. [DOI: 10.1016/j.idh.2018.06.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
14
|
Intraoperative endoscopy: An important skill for general surgeons. TECHNIQUES IN GASTROINTESTINAL ENDOSCOPY 2018. [DOI: 10.1016/j.tgie.2018.09.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
15
|
Hariharan P, Paruchuri SS, Topoleski LDT, Rinaldi JE, Casamento JP, Myers MR, Vesnovsky O. A test method to assess the contribution of fluid shear stress to the cleaning of reusable device surfaces. J Biomed Mater Res B Appl Biomater 2018; 107:1132-1140. [PMID: 30184332 DOI: 10.1002/jbm.b.34206] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Revised: 06/27/2018] [Accepted: 06/28/2018] [Indexed: 01/18/2023]
Abstract
Adequate cleaning of reusable medical devices is critical for preventing cross-infection among patients. For reusable medical devices, cleaning using mechanical brushes and detergent may not be sufficient to completely remove the infectious contaminants from the surfaces. This study evaluates the role of fluid flow-induced shear stress in the detachment and removal of contaminants from device surfaces. A stainless-steel test coupon, acting as a surrogate for a device surface, was coated with artificial clot of varying mass. The test coupon was exposed to fluid shear stress both with and without an enzymatic detergent. The relationship between clot removal quantity and the applied shear stress was obtained for multiple clot masses. Our results showed that fluid shear increased the effectiveness of the cleaning process. In the absence of flow, soaking the clot surface in the enzymatic detergent removed 67%, 77%, and 95% of the clot for 16 mg, 6.8 mg, and 1 mg initial masses, respectively. In the presence of fluid shear (0.3 Pa for 5 min), approximately 85%, 97%, and 99% of the clot was removed from the surface. The clot mass removed followed a linear relationship (R2 = 0.98) versus the applied fluid shear stress. This study showed that different cleaning processes such as fluid shear and detergent action contribute to the soil removal process. This method could be used to evaluate cleaning protocols for minimizing contaminant residue after the reprocessing of medical devices. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1132-1140, 2019.
Collapse
Affiliation(s)
- Prasanna Hariharan
- Division of Applied Mechanics, Center for Devices and Radiological length (CDRH), US FDA, Silver Spring, MD, United States
| | - Sai Sameer Paruchuri
- Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH, United States
| | - L D Timmie Topoleski
- Department of Mechanical Engineering, University of Maryland, Baltimore County, Baltimore, Maryland, United States
| | - Jean E Rinaldi
- Division of Applied Mechanics, Center for Devices and Radiological length (CDRH), US FDA, Silver Spring, MD, United States
| | - Jon P Casamento
- Division of Applied Mechanics, Center for Devices and Radiological length (CDRH), US FDA, Silver Spring, MD, United States
| | - Matthew R Myers
- Division of Applied Mechanics, Center for Devices and Radiological length (CDRH), US FDA, Silver Spring, MD, United States
| | - Oleg Vesnovsky
- Division of Applied Mechanics, Center for Devices and Radiological length (CDRH), US FDA, Silver Spring, MD, United States
| |
Collapse
|
16
|
Terjesen CL, Kovaleva J, Ehlers L. Early Assessment of the Likely Cost Effectiveness of Single-Use Flexible Video Bronchoscopes. PHARMACOECONOMICS - OPEN 2017; 1:133-141. [PMID: 29442335 PMCID: PMC5691847 DOI: 10.1007/s41669-017-0012-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
BACKGROUND Bronchoscopic procedures are common in the clinical setting, with estimates indicating 500,000 are undertaken per year in the USA alone. These procedures are generally regarded as safe. Unfortunately, a risk of cross-contamination between patients, with possible subsequent infection, is associated with the re-usable technology typically used in these procedures. OBJECTIVE Our objective was to conduct an early cost-effectiveness analysis (CEA) of single-use flexible video bronchoscope technology compared with the current reusable technology in a US hospital intensive care setting. METHODS We conducted a CEA to determine an incremental cost-effectiveness ratio (ICER), and constructed a decision analytic model based on the best available evidence from a literature search and a Delphi panel. We also conducted several one- and two-way sensitivity analyses and a probabilistic sensitivity analysis to illuminate the uncertainty associated with the estimates. RESULTS The literature search showed ample evidence of risk, albeit little of it was quantifiable. Estimates from the Delphi method found approximately a 3% risk of cross-contamination and approximately a 21% risk of subsequent infection. Pneumonia was estimated as the most likely manifestation of infection. The CEA showed a saving of $US118 per procedure and elimination of 0.7% of the risk of infection with the single-use technology. Relevant sensitivity analyses generally validated this result. CONCLUSION This study suggests that implementation of the single-use technology in the intensive care unit is cost effective in most scenarios. However, this result should be interpreted with caution because of the lack of certain knowledge on this particular topic.
Collapse
Affiliation(s)
| | | | - Lars Ehlers
- Danish Center for Healthcare Improvements, Aalborg University, Fibigerstraede 11, 9220, Aalborg, Denmark.
| |
Collapse
|
17
|
Terjesen CL, Kovaleva J, Ehlers L. Early Assessment of the Likely Cost Effectiveness of Single-Use Flexible Video Bronchoscopes. PHARMACOECONOMICS - OPEN 2017; 1:133-141. [PMID: 29442335 DOI: 10.1007/s41669-017-0012-9lk] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
BACKGROUND Bronchoscopic procedures are common in the clinical setting, with estimates indicating 500,000 are undertaken per year in the USA alone. These procedures are generally regarded as safe. Unfortunately, a risk of cross-contamination between patients, with possible subsequent infection, is associated with the re-usable technology typically used in these procedures. OBJECTIVE Our objective was to conduct an early cost-effectiveness analysis (CEA) of single-use flexible video bronchoscope technology compared with the current reusable technology in a US hospital intensive care setting. METHODS We conducted a CEA to determine an incremental cost-effectiveness ratio (ICER), and constructed a decision analytic model based on the best available evidence from a literature search and a Delphi panel. We also conducted several one- and two-way sensitivity analyses and a probabilistic sensitivity analysis to illuminate the uncertainty associated with the estimates. RESULTS The literature search showed ample evidence of risk, albeit little of it was quantifiable. Estimates from the Delphi method found approximately a 3% risk of cross-contamination and approximately a 21% risk of subsequent infection. Pneumonia was estimated as the most likely manifestation of infection. The CEA showed a saving of $US118 per procedure and elimination of 0.7% of the risk of infection with the single-use technology. Relevant sensitivity analyses generally validated this result. CONCLUSION This study suggests that implementation of the single-use technology in the intensive care unit is cost effective in most scenarios. However, this result should be interpreted with caution because of the lack of certain knowledge on this particular topic.
Collapse
Affiliation(s)
| | | | - Lars Ehlers
- Danish Center for Healthcare Improvements, Aalborg University, Fibigerstraede 11, 9220, Aalborg, Denmark.
| |
Collapse
|
18
|
Ofstead CL, Wetzler HP, Heymann OL, Johnson EA, Eiland JE, Shaw MJ. Longitudinal assessment of reprocessing effectiveness for colonoscopes and gastroscopes: Results of visual inspections, biochemical markers, and microbial cultures. Am J Infect Control 2017; 45:e26-e33. [PMID: 28159069 DOI: 10.1016/j.ajic.2016.10.017] [Citation(s) in RCA: 78] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Revised: 10/17/2016] [Accepted: 10/17/2016] [Indexed: 01/09/2023]
Abstract
BACKGROUND Flexible endoscopes are currently reused following cleaning and high-level disinfection. Contamination has been found on endoscopes, and infections have been linked to gastrointestinal, respiratory, and urologic endoscopes. METHODS This longitudinal study involved visual inspections with a borescope, microbial cultures, and biochemical tests for protein and adenosine triphosphate to identify endoscopes in need of further cleaning or maintenance. Three assessments were conducted over a 7-month period. Control group endoscopes reprocessed using customary practices were compared with intervention group endoscopes subjected to more rigorous reprocessing. RESULTS At final assessment, all endoscopes (N = 20) had visible irregularities. Researchers observed fluid (95%), discoloration, and debris in channels. Of 12 (60%) endoscopes with microbial growth, 4 had no growth until after 48 hours. There were no significant differences in culture results by study group, assessment period, or endoscope type. Similar proportions of control and intervention endoscopes (~20%) exceeded postcleaning biochemical test benchmarks. Adenosine triphosphate levels were higher for gastroscopes than colonoscopes (P = .014). Eighty-five percent of endoscopes required repair due to findings. CONCLUSIONS More rigorous reprocessing was not consistently effective. Seven-day incubation allowed identification of slow-growing microbes. These findings bolster the need for routine visual inspection and cleaning verification tests recommended in new reprocessing guidelines.
Collapse
Affiliation(s)
| | | | | | | | | | - Michael J Shaw
- Division of Gastroenterology, Department of Medicine, University of Minnesota Medical School, Minneapolis, MN
| |
Collapse
|
19
|
Gluck N, Melhem A, Halpern Z, Mergener K, Santo E. A novel self-propelled disposable colonoscope is effective for colonoscopy in humans (with video). Gastrointest Endosc 2016; 83:998-1004.e1. [PMID: 26391735 DOI: 10.1016/j.gie.2015.08.083] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2015] [Accepted: 08/19/2015] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIMS The self-propelled disposable colonoscope (SPDC) with a 360° view is designed to enhance visualization, minimize risks of perforation and infection transmission, and shorten operator training time associated with conventional colonoscopy (CC). We evaluated SPDC efficacy for cecal intubation and safety. METHODS Prospective patients presenting for colorectal cancer screening underwent SPDC immediately followed by CC. Initial patients necessary for SPDC operators to achieve proficiency comprised the training cohort. Subsequent enrolled patients comprised the study cohort. SPDC colonoscopy was performed up to the cecum, where anatomic landmarks were photographed and mucosal suction marks were placed. During SPDC withdrawal, polyps were recorded and similarly marked. On the second pass (by using CC), any potential mucosal damage and suction marks from the SPDC as well as polyps were recorded. Main endpoints included SPDC cecal intubation rates, confirmed by anatomic landmarks and residual marks seen on subsequent CC, and frequency and severity of adverse events and mucosal damage with SPDC. The secondary endpoint was subjective procedure proficiency, evaluated by the operator based on the training cohort. The tertiary endpoint was documenting pathologies visualized with SPDC. RESULTS Fifty-six of 58 enrolled subjects completed the study. Proficiency with SPDC was attained after 8 to 10 procedures. Cecal intubation was successful in 98.2% (55/56 subjects; 95% confidence interval [CI], 90.4%-99.9%), including 100% (95% CI, 90.7%-100%) of the study cohort and 94.4% (95% CI, 72.7%-99.9%) of the training cohort. No mucosal damage or adverse events were reported. SPDC detected 87.5% of polyps seen in tandem CC, including all polyps larger than 5 mm. CONCLUSIONS SPDC was highly successful, simple to use, and safe in achieving complete colonoscopy (cecal intubation). ( CLINICAL TRIAL REGISTRATION NUMBER 0692-12-TLV.).
Collapse
Affiliation(s)
- Nathan Gluck
- Tel Aviv Medical Center, Tel Aviv, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Alaa Melhem
- Tel Aviv Medical Center, Tel Aviv, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Zamir Halpern
- Tel Aviv Medical Center, Tel Aviv, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | | | - Erwin Santo
- Tel Aviv Medical Center, Tel Aviv, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
20
|
Alfa M, Olson N. Physical and composition characteristics of clinical secretions compared with test soils used for validation of flexible endoscope cleaning. J Hosp Infect 2016; 93:83-8. [DOI: 10.1016/j.jhin.2016.01.023] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2015] [Accepted: 02/04/2016] [Indexed: 10/22/2022]
|
21
|
Ryu JK, Kim EY, Kwon KA, Choi IJ, Hahm KB. Role of Clinical Endoscopy in Emphasizing Endoscope Disinfection. Clin Endosc 2015; 48:351-5. [PMID: 26473114 PMCID: PMC4604269 DOI: 10.5946/ce.2015.48.5.351] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2015] [Accepted: 08/29/2015] [Indexed: 01/12/2023] Open
Abstract
Based on the unexpected Middle East respiratory syndrome (MERS) outbreak in Korea, it was established that the virus can spread easily, MERS exposure in hospitals carries an extreme risk for infection as well as mortality, and the sharing of information was essential for infection control. Although the incidence of exogenous infections related to contaminated endoscopes is very low, the majority of published outbreaks have been caused by various shortcomings in reprocessing procedures, including insufficient training or awareness. Ever since the inauguration of "Clinical Endoscopy" as an English-language journal of the Korean Society of Gastrointestinal Endoscopy in 2011, it has published several articles on disinfection of the endoscope and its accessories. Many Science Citation Index journals have also emphasized high-level disinfection of the gastrointestinal endoscope. Many papers have been produced specifically, since the outbreak of carbapenem-resistant Enterobacteriaceae in 2013. The recent review papers concluded that quality control is the most important issue among all the aspects of procedural care, including the efficiency of the gastrointestinal endoscopy unit and reprocessing room. Thorough reprocessing of endoscopes using high-level disinfection and sterilization methods may be essential for reducing the risk of infection.
Collapse
Affiliation(s)
- Ji Kon Ryu
- Department of Internal Medicine and Liver Research Institute, Seoul National University College of Medicine, Seoul, Korea
| | - Eun Young Kim
- Department of Internal Medicine, Catholic University of Daegu School of Medicine, Daegu, Korea
| | - Kwang An Kwon
- Department of Gastroenterology, Gachon University Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
| | - Il Ju Choi
- Center for Gastric Cancer, National Cancer Center, Goyang, Korea
| | - Ki Baik Hahm
- Digestive Disease Center, CHA Bundang Medical Center, CHA University, Seongnam, Korea
| |
Collapse
|
22
|
A Journey into the Technical Evolution of Neuroendoscopy. World Neurosurg 2014; 82:e777-89. [DOI: 10.1016/j.wneu.2014.09.005] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2014] [Revised: 06/21/2014] [Accepted: 09/04/2014] [Indexed: 11/24/2022]
|
23
|
Kampf G, Fliss PM, Martiny H. Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes? World J Gastrointest Endosc 2014; 6:390-406. [PMID: 25228941 PMCID: PMC4163721 DOI: 10.4253/wjge.v6.i9.390] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2013] [Revised: 08/01/2014] [Accepted: 09/04/2014] [Indexed: 02/05/2023] Open
Abstract
The bioburden (blood, protein, pathogens and biofilm) on flexible endoscopes after use is often high and its removal is essential to allow effective disinfection, especially in the case of peracetic acid-based disinfectants, which are easily inactivated by organic material. Cleaning processes using conventional cleaners remove a variable but often sufficient amount of the bioburden. Some formulations based on peracetic acid are recommended by manufacturers for the cleaning step. We performed a systematic literature search and reviewed the available evidence to clarify the suitability of peracetic acid-based formulations for cleaning flexible endoscopes. A total of 243 studies were evaluated. No studies have yet demonstrated that peracetic acid-based cleaners are as effective as conventional cleaners. Some peracetic acid-based formulations have demonstrated some biofilm-cleaning effects and no biofilm-fixation potential, while others have a limited cleaning effect and a clear biofilm-fixation potential. All published data demonstrated a limited blood cleaning effect and a substantial blood and nerve tissue fixation potential of peracetic acid. No evidence-based guidelines on reprocessing flexible endoscopes currently recommend using cleaners containing peracetic acid, but some guidelines clearly recommend not using them because of their fixation potential. Evidence from some outbreaks, especially those involving highly multidrug-resistant gram-negative pathogens, indicated that disinfection using peracetic acid may be insufficient if the preceding cleaning step is not performed adequately. Based on this review we conclude that peracetic acid-based formulations should not be used for cleaning flexible endoscopes.
Collapse
|
24
|
Visrodia KH, Ofstead CL, Yellin HL, Wetzler HP, Tosh PK, Baron TH. The use of rapid indicators for the detection of organic residues on clinically used gastrointestinal endoscopes with and without visually apparent debris. Infect Control Hosp Epidemiol 2014; 35:987-94. [PMID: 25026614 DOI: 10.1086/677148] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
BACKGROUND Outbreaks of multidrug-resistant organisms have been linked to endoscope reprocessing lapses. Meticulous manual cleaning before high-level disinfection (HLD) is essential in reducing residual contamination that can interfere with HLD. Current reprocessing guidelines state that visual inspection is sufficient to confirm adequate cleaning. OBJECTIVE Our aim was to evaluate contamination of clinically used endoscopes, using visual inspection and rapid indicator tests before and after manual cleaning. A second objective was to determine which rapid indicator instruments and methods could be used for quality improvement initiatives in endoscope reprocessing. DESIGN Clinical use study of endoscope reprocessing effectiveness. SETTING Tertiary care teaching hospital with an inpatient endoscopy center. METHODS Researchers sampled endoscopes used for gastrointestinal procedures before and after manual cleaning. The external surfaces and 1 channel of each endoscope were visually inspected and tested with rapid indicators to measure protein, blood, and adenosine triphosphate (ATP) contamination levels. RESULTS Multiple components were sampled during 37 encounters with 12 unique endoscopes. All bedside-cleaned endoscopes had high levels of ATP and detectable blood or protein, whether or not any residue was visible. Although there was no visible residue on any endoscopes after manual cleaning, 82% had at least 1 positive rapid indicator test. CONCLUSIONS Relying solely on visual inspection of endoscopes prior to HLD is insufficient to ensure reprocessing effectiveness. For quality assurance initiatives, tests of different endoscope components using more than 1 indicator may be necessary. Additional research is needed to validate specific monitoring protocols.
Collapse
Affiliation(s)
- Kavel H Visrodia
- Department of Internal Medicine, Mayo Clinic, Rochester, Minnesota
| | | | | | | | | | | |
Collapse
|
25
|
Dirlam Langlay AM, Ofstead CL, Mueller NJ, Tosh PK, Baron TH, Wetzler HP. Reported gastrointestinal endoscope reprocessing lapses: the tip of the iceberg. Am J Infect Control 2013; 41:1188-94. [PMID: 24021660 DOI: 10.1016/j.ajic.2013.04.022] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2013] [Revised: 04/22/2013] [Accepted: 04/22/2013] [Indexed: 11/27/2022]
Abstract
BACKGROUND Most cases of microbial transmission to patients via contaminated endoscopes have resulted from nonadherence to reprocessing guidelines. We evaluated the occurrence, features, and implications of reprocessing lapses to gauge the nature and breadth of the problem in the context of widely available and accepted practice guidelines. METHODS We examined peer-reviewed and non-peer-reviewed literature to identify lapses reported in North America during 2005 to 2012 resulting in patient exposure to potentially contaminated gastrointestinal endoscopes. RESULTS Lapses occurred in various types of facilities and involved errors in all major steps of reprocessing. Each lapse continued for several months or years until the problem was discovered except for one that was described as a single incident. There were significant implications for patients, including notification and testing, microbial transmission, and increased morbidity and mortality. Only 1 reprocessing lapse was found in a peer-reviewed journal article, and other incidents were reported in governmental reports, legal documents, conference abstracts, and media reports. CONCLUSION Reprocessing lapses are an ongoing and widespread problem despite the existence of guidelines. Lack of publication in peer-reviewed literature contributes to the perception that lapses are rare and inconsequential. Reporting requirements and epidemiologic investigations are needed to develop better evidence-based policies and practices.
Collapse
|
26
|
Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy. Clin Microbiol Rev 2013; 26:231-54. [PMID: 23554415 DOI: 10.1128/cmr.00085-12] [Citation(s) in RCA: 294] [Impact Index Per Article: 26.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Flexible endoscopy is a widely used diagnostic and therapeutic procedure. Contaminated endoscopes are the medical devices frequently associated with outbreaks of health care-associated infections. Accurate reprocessing of flexible endoscopes involves cleaning and high-level disinfection followed by rinsing and drying before storage. Most contemporary flexible endoscopes cannot be heat sterilized and are designed with multiple channels, which are difficult to clean and disinfect. The ability of bacteria to form biofilms on the inner channel surfaces can contribute to failure of the decontamination process. Implementation of microbiological surveillance of endoscope reprocessing is appropriate to detect early colonization and biofilm formation in the endoscope and to prevent contamination and infection in patients after endoscopic procedures. This review presents an overview of the infections and cross-contaminations related to flexible gastrointestinal endoscopy and bronchoscopy and illustrates the impact of biofilm on endoscope reprocessing and postendoscopic infection.
Collapse
|
27
|
|