1
|
Rowan NJ, Kremer T, McDonnell G. A review of Spaulding's classification system for effective cleaning, disinfection and sterilization of reusable medical devices: Viewed through a modern-day lens that will inform and enable future sustainability. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 878:162976. [PMID: 36963674 DOI: 10.1016/j.scitotenv.2023.162976] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 02/23/2023] [Accepted: 03/17/2023] [Indexed: 05/13/2023]
Abstract
Despite advances in medicine and innovations in many underpinning fields including disease prevention and control, the Spaulding classification system, originally proposed in 1957, remains widely used for defining the disinfection and sterilization of contaminated re-usable medical devices and surgical instruments. Screening PubMed and Scopus databases using a PRISMA guiding framework generated 272 relevant publications that were used in this review. Findings revealed that there is a need to evolve how medical devices are designed, and processed by cleaning, disinfection (and/or sterilization) to mitigate patient risks, including acquiring an infection. This Spaulding Classification remains in use as it is logical, easily applied and understood by users (microbiologists, epidemiologists, manufacturers, industry) and by regulators. However, substantial changes have occurred over the past 65 years that challenge interpretation and application of this system that includes inter alia emergence of new pathogens (viruses, mycobacteria, protozoa, fungi), a greater understanding of innate and adaptive microbial tolerance to disinfection, toxicity risks, increased number of vulnerable patients and associated patient procedures, and greater complexity in design and use of medical devices. Common cited examples include endoscopes that enable non- or minimal invasive procedures but are highly sophisticated with various types of materials (polymers, electronic components etc), long narrow channels, right angle and heat-sensitive components and various accessories (e.g., values) that can be contaminated with high levels of microbial bioburden and patient tissues after use. Contaminated flexible duodenoscopes have been a source of several significant infection outbreaks, where at least 9 reported cases were caused by multidrug resistant organisms [MDROs] with no obvious breach in processing detected. Despite this, there is evidence of the lack of attention to cleaning and maintenance of these devices and associated equipment. Over the last few decades there is increasing genomic evidence of innate and adaptive resistance to chemical disinfectant methods along with adaptive tolerance to environmental stresses. To reduce these risks, it has been proposed to elevate classification of higher-risk flexible endoscopes (such as duodenoscopes) from semi-critical [contact with mucous membrane and intact skin] to critical use [contact with sterile tissue and blood] that entails a transition to using low-temperature sterilization modalities instead of routinely using high-level disinfection; thus, increasing the margin of safety for endoscope processing. This timely review addresses important issues surrounding use of the Spaulding classification system to meet modern-day needs. It specifically addresses the need for automated, robust cleaning and drying methods combined with using real-time monitoring of device processing. There is a need to understand entire end-to-end processing of devices instead of adopting silo approaches that in the future will be informed by artificial intelligence and deep-learning/machine learning. For example, combinational solutions that address the formation of complex biofilms that harbour pathogenic and opportunistic microorganisms on the surfaces of processed devices. Emerging trends are addressed including future sustainability for the medical devices sector that can be enabled via a new Quintuple Helix Hub approach that combines academia, industry, healthcare, regulators, and society to unlock real world solutions.
Collapse
Affiliation(s)
- N J Rowan
- Centre for Sustainable Disinfection and Sterilization, Bioscience Research Institute, Technological University of the Shannon Midlands Midwest, Athlone Campus, Ireland; Department of Nursing and Healthcare, Technological University of the Shannon Midwest Mideast, Athlone Campus, Ireland; SFI-funded CURAM Centre for Medical Device Research, University of Galway, Ireland.
| | - T Kremer
- Centre for Sustainable Disinfection and Sterilization, Bioscience Research Institute, Technological University of the Shannon Midlands Midwest, Athlone Campus, Ireland; Microbiological Quality & Sterility Assurance, Johnson & Johnson, 1000 Route 202, South Raritan, NJ 08869, USA
| | - G McDonnell
- Microbiological Quality & Sterility Assurance, Johnson & Johnson, 1000 Route 202, South Raritan, NJ 08869, USA
| |
Collapse
|
2
|
Adkin P, Hitchcock A, Smith LJ, Walsh SE. Priming with biocides: a pathway to antibiotic resistance? J Appl Microbiol 2022; 133:830-841. [PMID: 35384175 PMCID: PMC9543593 DOI: 10.1111/jam.15564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 12/08/2021] [Accepted: 03/24/2022] [Indexed: 11/28/2022]
Abstract
AIMS To investigate the priming effects of sub-inhibitory concentrations of biocides on antibiotic resistance in bacteria. METHODS AND RESULTS Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus were exposed to sub-inhibitory concentrations of biocides via a gradient plate method. Minimum inhibitory concentration (MIC) and antibiotic susceptibility were determined, and efflux pump inhibitors (thioridazine and chlorpromazine) were used to investigate antibiotic resistance mechanism(s). Escherichia coli displayed a 2-fold increase in MIC (32 to 64 mg l-1) to H2 O2 which was stable after 15 passages, but lost after 6 weeks, and P. aeruginosa displayed a 2-fold increase in MIC (64 to 128 mg l-1) to BZK which was also stable for 15 passages. There were no other tolerances observed to biocides in E. coli, P. aeruginosa or S. aureus, however stable cross-resistance to antibiotics was observed in the absence of a stable increased tolerance to biocides. Six-fold increases in MIC to cephalothin and four-fold to ceftriaxone and ampicillin were observed in hydrogen peroxide primed E. coli. Chlorhexidine primed S. aureus showed a four-fold increase in MIC to oxacillin, and glutaraldehyde-primed P. aeruginosa showed four-fold (sulphatriad) and eight-fold (ciprofloxacin) increases in MIC. Thioridazine increased the susceptibility of E. coli to cephalothin and cefoxitin by four and two-fold respectively, and both thioridazine and chlorpromazine increased the susceptibility S. aureus to oxacillin by eight and four-fold respectively. CONCLUSIONS These findings demonstrate that sub-inhibitory concentrations of biocides can prime bacteria to become resistant to antibiotics even in the absence of stable biocide tolerance and suggests activation of efflux mechanisms may be a contributory factor. SIGNIFICANCE AND IMPACT OF THE STUDY This study demonstrates the effects of low-level exposure of biocides (priming) on antibiotic resistance even in the absence of obvious increased biocidal tolerance.
Collapse
Affiliation(s)
- Pat Adkin
- Leicester School of Pharmacy, Hawthorn Building, De Montfort University, Leicester, LE1 1BH, UK
| | - Andrew Hitchcock
- School of Biosciences, University of Sheffield, Sheffield, S10 2TN, UK
| | - Laura J Smith
- Leicester School of Pharmacy, Hawthorn Building, De Montfort University, Leicester, LE1 1BH, UK
| | - Susannah E Walsh
- Leicester School of Pharmacy, Hawthorn Building, De Montfort University, Leicester, LE1 1BH, UK.,School of Pharmacy and Life Sciences, Robert Gordon University, Aberdeen, AB10 7AQ, UK
| |
Collapse
|
3
|
El Zowalaty ME, Al Thani AA, Webster TJ, El Zowalaty AE, Schweizer HP, Nasrallah GK, Marei HE, Ashour HM. Pseudomonas aeruginosa: arsenal of resistance mechanisms, decades of changing resistance profiles, and future antimicrobial therapies. Future Microbiol 2015; 10:1683-706. [PMID: 26439366 DOI: 10.2217/fmb.15.48] [Citation(s) in RCA: 88] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Abstract
Antimicrobial resistance is one of the most serious public health issues facing humans since the discovery of antimicrobial agents. The frequent, prolonged, and uncontrolled use of antimicrobial agents are major factors in the emergence of antimicrobial-resistant bacterial strains, including multidrug-resistant variants. Pseudomonas aeruginosa is a leading cause of nosocomial infections. The abundant data on the increased resistance to antipseudomonal agents support the need for global action. There is a paucity of new classes of antibiotics active against P. aeruginosa. Here, we discuss recent antibacterial resistance profiles and mechanisms of resistance by P. aeruginosa. We also review future potential methods for controlling antibiotic-resistant bacteria, such as phage therapy, nanotechnology and antipseudomonal vaccines.
Collapse
Affiliation(s)
- Mohamed E El Zowalaty
- Department of Microbiology & Immunology, Emory University School of Medicine, Atlanta, GA 30322, USA.,BioMedical Research Center, Qatar University, Doha, PO Box 2713, Qatar
| | - Asmaa A Al Thani
- BioMedical Research Center, Qatar University, Doha, PO Box 2713, Qatar.,Department of Health Sciences, College of Arts and Sciences, Qatar University, Doha 2713, Qatar
| | - Thomas J Webster
- Department of Chemical Engineering, Northeastern University, Boston, MA 02018, USA.,Center of Excellence for Advanced Materials Research, King Abdulaziz University, Jeddah, Kingdom of Saudi Arabia
| | - Ahmed E El Zowalaty
- Department of Physiology & Pharmacology, College of Veterinary Medicine, University of Georgia, Athens, GA 30602, USA.,Interdisciplinary Toxicology Program, University of Georgia, Athens, GA 30602, USA
| | - Herbert P Schweizer
- Department of Molecular Genetics & Microbiology, College of Medicine, University of Florida, Gainesville, FL 32611, USA.,Emerging Pathogens Institute, Institute for Therapeutic Innovation, University of Florida Gainesville, FL 32611, USA
| | - Gheyath K Nasrallah
- BioMedical Research Center, Qatar University, Doha, PO Box 2713, Qatar.,Department of Health Sciences, College of Arts and Sciences, Qatar University, Doha 2713, Qatar
| | - Hany E Marei
- BioMedical Research Center, Qatar University, Doha, PO Box 2713, Qatar
| | - Hossam M Ashour
- Department of Microbiology & Immunology, Faculty of Pharmacy, Cairo University, Egypt.,Department of Pharmacy Practice, Eugene Applebaum College of Pharmacy & Health Sciences, Wayne State University, Detroit, MI, USA
| |
Collapse
|
4
|
Efflux as a glutaraldehyde resistance mechanism in Pseudomonas fluorescens and Pseudomonas aeruginosa biofilms. Antimicrob Agents Chemother 2015; 59:3433-40. [PMID: 25824217 DOI: 10.1128/aac.05152-14] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2014] [Accepted: 03/21/2015] [Indexed: 01/13/2023] Open
Abstract
A major challenge in microbial biofilm control is biocide resistance. Phenotypic adaptations and physical protective effects have been historically thought to be the primary mechanisms for glutaraldehyde resistance in bacterial biofilms. Recent studies indicate the presence of genetic mechanisms for glutaraldehyde resistance, but very little is known about the contributory genetic factors. Here, we demonstrate that efflux pumps contribute to glutaraldehyde resistance in Pseudomonas fluorescens and Pseudomonas aeruginosa biofilms. The RNA-seq data show that efflux pumps and phosphonate degradation, lipid biosynthesis, and polyamine biosynthesis metabolic pathways were induced upon glutaraldehyde exposure. Furthermore, chemical inhibition of efflux pumps potentiates glutaraldehyde activity, suggesting that efflux activity contributes to glutaraldehyde resistance. Additionally, induction of known modulators of biofilm formation, including phosphonate degradation, lipid biosynthesis, and polyamine biosynthesis, may contribute to biofilm resistance and resilience. Fundamental understanding of the genetic mechanism of biocide resistance is critical for the optimization of biocide use and development of novel disinfection strategies. Our results reveal genetic components involved in glutaraldehyde resistance and a potential strategy for improved control of biofilms.
Collapse
|
5
|
Kampf G, Fliss PM, Martiny H. Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes? World J Gastrointest Endosc 2014; 6:390-406. [PMID: 25228941 PMCID: PMC4163721 DOI: 10.4253/wjge.v6.i9.390] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2013] [Revised: 08/01/2014] [Accepted: 09/04/2014] [Indexed: 02/05/2023] Open
Abstract
The bioburden (blood, protein, pathogens and biofilm) on flexible endoscopes after use is often high and its removal is essential to allow effective disinfection, especially in the case of peracetic acid-based disinfectants, which are easily inactivated by organic material. Cleaning processes using conventional cleaners remove a variable but often sufficient amount of the bioburden. Some formulations based on peracetic acid are recommended by manufacturers for the cleaning step. We performed a systematic literature search and reviewed the available evidence to clarify the suitability of peracetic acid-based formulations for cleaning flexible endoscopes. A total of 243 studies were evaluated. No studies have yet demonstrated that peracetic acid-based cleaners are as effective as conventional cleaners. Some peracetic acid-based formulations have demonstrated some biofilm-cleaning effects and no biofilm-fixation potential, while others have a limited cleaning effect and a clear biofilm-fixation potential. All published data demonstrated a limited blood cleaning effect and a substantial blood and nerve tissue fixation potential of peracetic acid. No evidence-based guidelines on reprocessing flexible endoscopes currently recommend using cleaners containing peracetic acid, but some guidelines clearly recommend not using them because of their fixation potential. Evidence from some outbreaks, especially those involving highly multidrug-resistant gram-negative pathogens, indicated that disinfection using peracetic acid may be insufficient if the preceding cleaning step is not performed adequately. Based on this review we conclude that peracetic acid-based formulations should not be used for cleaning flexible endoscopes.
Collapse
|
6
|
Reichel M, Schlicht A, Ostermeyer C, Kampf G. Efficacy of surface disinfectant cleaners against emerging highly resistant gram-negative bacteria. BMC Infect Dis 2014; 14:292. [PMID: 24885029 PMCID: PMC4063421 DOI: 10.1186/1471-2334-14-292] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2014] [Accepted: 05/21/2014] [Indexed: 01/03/2023] Open
Abstract
Background Worldwide, the emergence of multidrug-resistant gram-negative bacteria is a clinical problem. Surface disinfectant cleaners (SDCs) that are effective against these bacteria are needed for use in high risk areas around patients and on multi-touch surfaces. We determined the efficacy of several SDCs against clinically relevant bacterial species with and without common types of multidrug resistance. Methods Bacteria species used were ATCC strains; clinical isolates classified as antibiotic-susceptible; and multi-resistant clinical isolates from Klebsiella oxytoca, Klebsiella pneumoniae, and Serratia marcescens (all OXA-48 and KPC-2); Acinetobacter baumannii (OXA-23); Pseudomonas aeruginosa (VIM-1); and Achromobacter xylosoxidans (ATCC strain). Experiments were carried out according to EN 13727:2012 in quadruplicate under dirty conditions. The five evaluated SDCs were based on alcohol and an amphoteric substance (AAS), an oxygen-releaser (OR), surface-active substances (SAS), or surface-active-substances plus aldehydes (SASA; two formulations). Bactericidal concentrations of SDCs were determined at two different contact times. Efficacy was defined as a log10 ≥ 5 reduction in bacterial cell count. Results SDCs based on AAS, OR, and SAS were effective against all six species irrespective of the degree of multi-resistance. The SASA formulations were effective against the bacteria irrespective of degree of multi-resistance except for one of the four P. aeruginosa isolates (VIM-1). We found no general correlation between SDC efficacy and degree of antibiotic resistance. Conclusions SDCs were generally effective against gram-negative bacteria with and without multidrug resistance. SDCs are therefore suitable for surface disinfection in the immediate proximity of patients. Single bacterial isolates, however, might have reduced susceptibility to selected biocidal agents.
Collapse
Affiliation(s)
| | | | | | - Günter Kampf
- Bode Science Center, Bode Chemie GmbH, Melanchthonstr, 27, 22525 Hamburg, Germany.
| |
Collapse
|