For: Bernstein DT, Alexander JJ, Petersen NJ, Lambert BS, Noble PC, Netscher DT. The Impact of Suture Caliber and Looped Configurations on the Suture-Tendon Interface in Zone II Flexor Tendon Repair. J Hand Surg Am 2019;44:156.e1-156.e8. [PMID: 29891271 DOI: 10.1016/j.jhsa.2018.04.029] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Revised: 12/20/2017] [Accepted: 04/26/2018] [Indexed: 02/02/2023]
Number Cited by Other Article(s)
1
Belloti JC, Buendia LA, Tamaoki MJ, Santos JBGD, Falopa F, Ulson HJR. Minimally Invasive Suture Technique Pull-out to Repair the Acute Flexor Tendons in Zone II of the Hand. Rev Bras Ortop 2024;59:e60-e67. [PMID: 38524718 PMCID: PMC10957262 DOI: 10.1055/s-0044-1779332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Accepted: 08/10/2023] [Indexed: 03/26/2024]  Open
2
Rizvanoglu İH, Kucuk U. Comparison of Clinical Outcomes of Endoscope-Assisted Technique and Conventional Surgery in Zone 2 Flexor Tendon Repair. J Hand Surg Am 2023;48:1161.e1-1161.e8. [PMID: 35690522 DOI: 10.1016/j.jhsa.2022.03.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Revised: 02/13/2022] [Accepted: 03/30/2022] [Indexed: 02/02/2023]
3
Lindsay C, Watson N, Yanik J, Glass N, Fowler T. Strength, bulk and surgery time of ex situ versus in situ flexor tendon repair in a cadaveric model. J Hand Surg Eur Vol 2023;48:137-143. [PMID: 36281068 DOI: 10.1177/17531934221131376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
4
Beyond the Core Suture: A New Approach to Tendon Repair. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2020;8:e3280. [PMID: 33425594 PMCID: PMC7787298 DOI: 10.1097/gox.0000000000003280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Accepted: 10/08/2020] [Indexed: 11/26/2022]
5
Mao WF, Wu YF. Effects of a Q Suture Technique on Resistance to Gap Formation and Tensile Strength of Repaired Tendons: An Ex Vivo Mechanical Study. J Hand Surg Am 2020;45:258.e1-258.e7. [PMID: 31451319 DOI: 10.1016/j.jhsa.2019.06.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Revised: 04/04/2019] [Accepted: 06/11/2019] [Indexed: 02/02/2023]