1
|
Zhang C, Tian K, Meng Z, Zhang J, Lu Y, Tan L, Zhang M, Xu D. A versatile dilution-treatment-detection microfluidic chip platform for rapid In vitro lung cancer drug combination sensitivity evaluation. Talanta 2024; 277:126298. [PMID: 38823330 DOI: 10.1016/j.talanta.2024.126298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 04/30/2024] [Accepted: 05/20/2024] [Indexed: 06/03/2024]
Abstract
Combination drug therapy represents an effective strategy for treating certain drug-resistant and intractable cancer cases. However, determining the optimal combination of drugs and dosages is challenging due to clonal diversity in patients' tumors and the lack of rapid drug sensitivity evaluation methods. Microfluidic technology offers promising solutions to this issue. In this study, we propose a versatile microfluidic chip platform capable of integrating all processes, including dilution, treatment, and detection, for in vitro drug sensitivity assays. This platform innovatively incorporates several modules, including automated discrete drug logarithmic concentration generation, on-chip cell perfusion culture, and parallel drug treatments of cancer cell models. Moreover, it is compatible with microplate readers or high-content imaging systems for swift detection and automated monitoring, simplifying on-chip drug evaluation. Proof of concept is demonstrated by assessing the in vitro potency of two drugs, cisplatin, and etoposide, against the lung adenocarcinoma A549 cell line, under both single-drug and combination treatment conditions. The findings reveal that, compared to conventional microplate approaches with static cultivation, this on-chip automated perfusion bioassays yield comparable IC50 values with lower variation and a 50 % reduction in drug preparation time. This versatile dilution-treatment-detection microfluidic platform offers a promising tool for rapid and precise drug assessments, facilitating in vitro drug sensitivity evaluation in personalized cancer chemotherapy.
Collapse
Affiliation(s)
- Chenchen Zhang
- School of Chemistry and Chemical Engineering, State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing, China
| | - Kuo Tian
- School of Chemistry and Chemical Engineering, State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing, China
| | - Zixun Meng
- School of Chemistry and Chemical Engineering, State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing, China
| | - Jianing Zhang
- School of Chemistry and Chemical Engineering, State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing, China
| | - Yihong Lu
- NMPA Key Laboratory for Impurity Profile of Chemical Drugs, Jiangsu Institute for Food and Drug Control, Nanjing, China
| | - Li Tan
- NMPA Key Laboratory for Impurity Profile of Chemical Drugs, Jiangsu Institute for Food and Drug Control, Nanjing, China
| | - Mei Zhang
- NMPA Key Laboratory for Impurity Profile of Chemical Drugs, Jiangsu Institute for Food and Drug Control, Nanjing, China
| | - Danke Xu
- School of Chemistry and Chemical Engineering, State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing, China.
| |
Collapse
|
2
|
Henkel T, Mayer G, Hampl J, Cao J, Ehrhardt L, Schober A, Groß GA. From Microtiter Plates to Droplets—There and Back Again. MICROMACHINES 2022; 13:mi13071022. [PMID: 35888839 PMCID: PMC9316479 DOI: 10.3390/mi13071022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 06/24/2022] [Accepted: 06/25/2022] [Indexed: 02/05/2023]
Abstract
Droplet-based microfluidic screening techniques can benefit from interfacing established microtiter plate-based screening and sample management workflows. Interfacing tools are required both for loading preconfigured microtiter-plate (MTP)-based sample collections into droplets and for dispensing the used droplets samples back into MTPs for subsequent storage or further processing. Here, we present a collection of Digital Microfluidic Pipetting Tips (DMPTs) with integrated facilities for droplet generation and manipulation together with a robotic system for its operation. This combination serves as a bidirectional sampling interface for sample transfer from wells into droplets (w2d) and vice versa droplets into wells (d2w). The DMPT were designed to fit into 96-deep-well MTPs and prepared from glass by means of microsystems technology. The aspirated samples are converted into the channel-confined droplets’ sequences separated by an immiscible carrier medium. To comply with the demands of dose-response assays, up to three additional assay compound solutions can be added to the sample droplets. To enable different procedural assay protocols, four different DMPT variants were made. In this way, droplet series with gradually changing composition can be generated for, e.g., 2D screening purposes. The developed DMPT and their common fluidic connector are described here. To handle the opposite transfer d2w, a robotic transfer system was set up and is described briefly.
Collapse
Affiliation(s)
- Thomas Henkel
- Leibniz Institute of Photonic Technology, Leibniz-IPHT, Albert-Einstein-Str. 9, 07745 Jena, Germany; (T.H.); (G.M.)
| | - Günter Mayer
- Leibniz Institute of Photonic Technology, Leibniz-IPHT, Albert-Einstein-Str. 9, 07745 Jena, Germany; (T.H.); (G.M.)
| | - Jörg Hampl
- Department of Nano-Biosystem Technology, Institute of Chemistry and Biotechnology, Technical University Ilmenau, Prof.-Schmidt-Str. 26, 98693 Ilmenau, Germany; (J.H.); (A.S.)
| | - Jialan Cao
- Department of Physical Chemistry and Microreaction Technologies, Institute of Chemistry and Biotechnology, Technical University Ilmenau, Prof.-Schmidt-Str. 26, 98693 Ilmenau, Germany; (J.C.); (L.E.)
| | - Linda Ehrhardt
- Department of Physical Chemistry and Microreaction Technologies, Institute of Chemistry and Biotechnology, Technical University Ilmenau, Prof.-Schmidt-Str. 26, 98693 Ilmenau, Germany; (J.C.); (L.E.)
| | - Andreas Schober
- Department of Nano-Biosystem Technology, Institute of Chemistry and Biotechnology, Technical University Ilmenau, Prof.-Schmidt-Str. 26, 98693 Ilmenau, Germany; (J.H.); (A.S.)
| | - Gregor Alexander Groß
- Department of Physical Chemistry and Microreaction Technologies, Institute of Chemistry and Biotechnology, Technical University Ilmenau, Prof.-Schmidt-Str. 26, 98693 Ilmenau, Germany; (J.C.); (L.E.)
- Correspondence: ; Tel.: +49-3677-69-3716
| |
Collapse
|
3
|
Abstract
Optofluidics represents the interaction of light and fluids on a chip that integrates microfluidics and optics, which provides a promising optical platform for manipulating and analyzing fluid samples. Recent years have witnessed a substantial growth in optofluidic devices, including the integration of optical and fluidic control units, the incorporation of diverse photonic nanostructures, and new applications. All these advancements have enabled the implementation of optofluidics with improved performance. In this review, the recent advances of fabrication techniques and cutting-edge applications of optofluidic devices are presented, with a special focus on the developments of imaging and sensing. Specifically, the optofluidic based imaging techniques and applications are summarized, including the high-throughput cytometry, biochemical analysis, and optofluidic nanoparticle manipulation. The optofluidic sensing section is categorized according to the modulation approaches and the transduction mechanisms, represented by absorption, reflection/refraction, scattering, and plasmonics. Perspectives on future developments and promising avenues in the fields of optofluidics are also provided.
Collapse
|
4
|
Shahrivar K, Del Giudice F. Controlled viscoelastic particle encapsulation in microfluidic devices. SOFT MATTER 2021; 17:8068-8077. [PMID: 34525163 DOI: 10.1039/d1sm00941a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The encapsulation of particles in droplets using microfluidic devices finds application across several fields ranging from biomedical engineering to materials science. The encapsulation process, however, is often affected by poor single encapsulation efficiency, quantified by the Poisson statistics, with droplets containing more than one particle or with several empty droplets. We here demonstrate that viscoelastic aqueous solutions of xanthan gum enable controlled single particle encapsulation in microfluidic devices with a single encapsulation efficiency up to 2-fold larger than the one predicted by the Poisson statistics. We achieved such a result by identifying viscoelastic xanthan gum aqueous solutions that could drive particle ordering before approaching the encapsulation area and simultaneously form uniform droplets. This is the first experimental evidence of viscoelastic encapsulation in microfluidic devices, the existing literature on the subject being focused on Newtonian suspending liquids. We first studied the process of viscoelastic droplet formation, and found that the droplet length normalised by the channel diameter scaled as predicted for Newtonian solutions. At variance with Newtonian solutions, we observed that the droplet formation mechanism became unstable above critical values of the Weissenberg number, which quantifies the elasticity of the xanthan gum solutions carrying the particles. In terms of controlled encapsulation, we discovered that the single encapsulation efficiency was larger than the Poisson values in a specific range of xanthan gum mass concentrations. Finally, we introduced an empirical formula that can help the design of controlled viscoelastic encapsulation systems.
Collapse
Affiliation(s)
- Keshvad Shahrivar
- Faculty of Science and Engineering, School of Engineering and Applied Science, Swansea University Fabian Way, Swansea, SA1 8EN, UK.
| | - Francesco Del Giudice
- Faculty of Science and Engineering, School of Engineering and Applied Science, Swansea University Fabian Way, Swansea, SA1 8EN, UK.
| |
Collapse
|
5
|
Tang J, Cao X, Qiu G, deMello A, Wang J. Optical-Switch-Enabled Microfluidics for Sensitive Multichannel Colorimetric Analysis. Anal Chem 2021; 93:6784-6791. [PMID: 33877822 DOI: 10.1021/acs.analchem.1c00674] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
The implementation of colorimetric analysis within microfluidic environments engenders significant benefits with respect to reduced sample and reagent consumption, system miniaturization, and real-time measurement of flowing samples. That said, conventional approaches to colorimetric analysis within microfluidic channels are hampered by short optical pathlengths and single-channel configurations, which lead to poor detection sensitivities and low analytical throughputs. Although the use of multiplexed light source/photodetector modules allows for multichannel analysis, such configurations significantly increase both instrument complexity and cost. To address these issues, we present a four-channel colorimetric measurement scheme within an optical-switch-enabled microfluidic chip (OSEMC) fabricated by two-photon stereolithography. The integration of optical switches enables sequential signal readout from each detection channel, and thus, only a single light source and a photodetector are required for operation. Optical switches can be controlled in a bespoke manner by changing the medium in the switch channel between a "light-transmitting" fluid and a "light-blocking" fluid using pneumatic microvalves. Such optical switches are characterized by fast response times (approximately 200 ms), tunable switching frequencies (between 0.1 and 1.0 Hz studied), and excellent stability. Operational performance demonstrates both good sensitivity and reproducibility through the colorimetric analysis of nitrite and ammonium samples using four detection channels. Furthermore, the use of OSEMC for parallel and real-time analysis of flowing samples is investigated via characterization of the adsorption kinetics of tartrazine on activated charcoal and the catalytic reaction kinetics of horseradish peroxidase (HRP).
Collapse
Affiliation(s)
- Jiukai Tang
- Institute of Environmental Engineering, ETH Zürich, Zürich 8093, Switzerland.,Laboratory for Advanced Analytical Technologies, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf 8600, Switzerland
| | - Xiaobao Cao
- Institute of Chemical and Bioengineering, ETH Zürich, Vladimir Prelog Weg 1, Zürich 8093, Switzerland
| | - Guangyu Qiu
- Institute of Environmental Engineering, ETH Zürich, Zürich 8093, Switzerland.,Laboratory for Advanced Analytical Technologies, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf 8600, Switzerland
| | - Andrew deMello
- Institute of Chemical and Bioengineering, ETH Zürich, Vladimir Prelog Weg 1, Zürich 8093, Switzerland
| | - Jing Wang
- Institute of Environmental Engineering, ETH Zürich, Zürich 8093, Switzerland.,Laboratory for Advanced Analytical Technologies, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf 8600, Switzerland
| |
Collapse
|