1
|
Huang X, Tong Y, Zhou F, Zhao Y, Li Q, Chen S, Xiao L, Zeng Z. Comparison of efficacy and safety of different asparaginases in adult acute lymphoblastic leukemia based on nano-magnetic beads immunoassay. Am J Transl Res 2024; 16:2931-2939. [PMID: 39114732 PMCID: PMC11301484 DOI: 10.62347/cqgk2579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Accepted: 05/17/2024] [Indexed: 08/10/2024]
Abstract
OBJECTIVE To compare the efficacy and safety of different asparaginase formulations in the treatment of acute lymphoblastic leukemia (ALL) based on nano-magnetic bead immunoassay. METHODS Retrospective analysis of adult ALL patients' clinical data who admitted to The Affiliated Hospital of Changsha Health Vocational College from August 2020 to August 2023. Finally, 65 adult ALL patients were included in this study, including the polyethylene glycol conjugated asparaginase (PEG-ASNase) group (n = 32) and the L-asparaginase (L-ASNase) group (n = 33). Enzyme-linked immunosorbent assay (ELISA) based on magnetic nanoparticles was used to determine the activity of ASNase in both groups. The levels of asparagine or glutamine in two groups were detected by automatic biochemical analyzer during induction therapy, and the adverse events of the two groups were observed during the treatment. RESULTS PEG-ASNase demonstrated a slower decrease in enzyme activity, longer action duration, and higher safety profile compared to L-ASNase. PEG-ASNase group and L-ASNase group demonstrated a similar complete remission rate (71.88% vs. 60.61%). Event-free survival was higher in patients receiving PEG-ASNase than those receiving L-ASNase (42.4% and 18.7%). The observed adverse reactions included allergic reactions, pancreatic lesions, gastrointestinal reactions and liver function damage. The incidence of gastrointestinal reactions and liver function damage was higher in the L-ASNase group than that in PEG-ASNase group (45.45% and 33.33%). CONCLUSION This study provides valuable insights into the asparaginase treatments in clinical, highlighting the importance of PEG-ASNase for improving treatment protocols in adult ALL patients.
Collapse
Affiliation(s)
- Xiaoshan Huang
- College of Pharmacy, Changsha Health Vocational CollegeChangsha 410000, Hunan, China
| | - Yi Tong
- College of Clinical Medicine, Changsha Health Vocational CollegeChangsha 410000, Hunan, China
| | - Feng Zhou
- College of Basic Medicine, Changsha Health Vocational CollegeChangsha 410000, Hunan, China
| | - Yunshuang Zhao
- College of Pharmacy, Changsha Health Vocational CollegeChangsha 410000, Hunan, China
| | - Qingqing Li
- College of Pharmacy, Changsha Health Vocational CollegeChangsha 410000, Hunan, China
| | - Siyu Chen
- College of Pharmacy, Changsha Health Vocational CollegeChangsha 410000, Hunan, China
| | - Lan Xiao
- College of Pharmacy, Changsha Health Vocational CollegeChangsha 410000, Hunan, China
| | - Zhaofeng Zeng
- Scientific Research Department, Changsha Health Vocational CollegeChangsha 410000, Hunan, China
| |
Collapse
|
2
|
Blazevic N, Rogic D, Pelajic S, Miler M, Glavcic G, Ratkajec V, Vrkljan N, Bakula D, Hrabar D, Pavic T. YKL-40 as a biomarker in various inflammatory diseases: A review. Biochem Med (Zagreb) 2024; 34:010502. [PMID: 38125621 PMCID: PMC10731731 DOI: 10.11613/bm.2024.010502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Accepted: 09/04/2023] [Indexed: 12/23/2023] Open
Abstract
YKL-40 or Chitinase-3-Like Protein 1 (CHI3L1) is a highly conserved glycoprotein that binds heparin and chitin in a non-enzymatic manner. It is a member of the chitinase protein family 18, subfamily A, and unlike true chitinases, YKL-40 is a chitinase-like protein without enzymatic activity for chitin. Although its accurate function is yet unknown, the pattern of its expression in the normal and disease states suggests its possible engagement in apoptosis, inflammation and remodeling or degradation of the extracellular matrix. During an inflammatory response, YKL-40 is involved in a complicated interaction between host and bacteria, both promoting and attenuating immune response and potentially being served as an autoantigen in a vicious circle of autoimmunity. Based on its pathophysiology and mechanism of action, the aim of this review was to summarize research on the growing role of YKL-40 as a persuasive biomarker for inflammatory diseases' early diagnosis, prediction and follow-up (e.g., cardiovascular, gastrointestinal, endocrinological, immunological, musculoskeletal, neurological, respiratory, urinary, infectious) with detailed structural and functional background of YKL-40.
Collapse
Affiliation(s)
- Nina Blazevic
- Department of Gastroenterology and Hepatology, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| | - Dunja Rogic
- Department of Laboratory Diagnostics, University Hospital Center Zagreb, Zagreb, Croatia
| | - Stipe Pelajic
- Department of Gastroenterology and Hepatology, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| | - Marijana Miler
- Department of Clinical Chemistry, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| | - Goran Glavcic
- Department of Surgery, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| | - Valentina Ratkajec
- Department of Gastroenterology, General Hospital Virovitica, Virovitica, Croatia
| | - Nikolina Vrkljan
- Department of Internal Medicine, Intensive Care Unit, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| | - Dejan Bakula
- Department of Gastroenterology and Hepatology, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| | - Davor Hrabar
- Department of Gastroenterology and Hepatology, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| | - Tajana Pavic
- Department of Gastroenterology and Hepatology, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| |
Collapse
|
3
|
Liao Y, Peng S, Huang L, Li Z, Hu J, Xu R, Tang W, Zhuang J. Analytical and Clinical Evaluation of a Chemiluminescent Immunoassay to Detect Serum Chitinase-3-like Protein 1 in HBV-Related Liver Diseases. Int J Anal Chem 2024; 2024:6688819. [PMID: 38304922 PMCID: PMC10830935 DOI: 10.1155/2024/6688819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 12/07/2023] [Accepted: 01/12/2024] [Indexed: 02/03/2024] Open
Abstract
Serum chitinase-3-like protein 1 (CHI3L1) is a diagnostic marker for liver diseases, such as hepatocellular carcinoma (HCC). Herein, we aimed to evaluate the analytical performance of a chemiluminescent immunoassay (CLIA) for the quantitative detection of CHI3L1 and its application in hepatitis B virus (HBV)-related liver diseases. The CLIA for CHI3L1 detection presented good analytical performance, with a linear range of 1.50-2000.00 ng/mL and a detection limit of 0.98 ng/mL. To evaluate its clinical application, serum CHI3L1 levels were detected in 82 patients with chronic hepatitis B (CHB) and in 21 healthy controls. The patients with CHB and HCC had higher CHI3L1 levels than the healthy controls and the patients with CHB without HCC. However, CHI3L1 levels did not change significantly with the increase in liver fibrosis stages. The area under the receiver operating characteristic curve for the diagnosis of HBV-related HCC was 0.808, representing a moderate diagnostic value. Correlation analysis revealed a significant association between CHI3L1 and alpha-fetoprotein (AFP) levels, the fibrosis-4 (FIB-4) index, and the aspartate aminotransferase-to-platelet ratio index (APRI). In conclusion, compared with currently reported methods for CHI3L1 detection, the CLIA has a high sensitivity, a wide linear range, and an acceptable accuracy, precision, and reference intervals, making it valuable in the diagnosis of HBV-related HCC.
Collapse
Affiliation(s)
- Yanqiang Liao
- Department of Laboratory Medicine, Doumen Qiaoli Hospital of Traditional Chinese Medicine, Zhuhai 519125, China
| | - Se Peng
- Department of Laboratory Medicine, Guangdong Provincial Hospital of Chinese Medicine, Zhuhai Hospital, Zhuhai 519015, China
| | - Lesheng Huang
- Department of Radiology, Guangdong Provincial Hospital of Chinese Medicine, Zhuhai Hospital, Zhuhai 519015, China
| | - Zhong Li
- Zhuhai Seesheen Medical Technology Company Limited, Zhuhai 519060, China
| | - Jian Hu
- Department of Laboratory Medicine, Guangdong Provincial Hospital of Chinese Medicine, Zhuhai Hospital, Zhuhai 519015, China
| | - Rui Xu
- Department of Laboratory Medicine, Guangdong Provincial Hospital of Chinese Medicine, Zhuhai Hospital, Zhuhai 519015, China
| | - Wenzhi Tang
- Department of Laboratory Medicine, Guangdong Provincial Hospital of Chinese Medicine, Zhuhai Hospital, Zhuhai 519015, China
| | - Jialing Zhuang
- Department of Laboratory Medicine, Guangdong Provincial Hospital of Chinese Medicine, Zhuhai Hospital, Zhuhai 519015, China
| |
Collapse
|
4
|
Makhneva E, Sklenárová D, Brandmeier JC, Hlaváček A, Gorris HH, Skládal P, Farka Z. Influence of Label and Solid Support on the Performance of Heterogeneous Immunoassays. Anal Chem 2022; 94:16376-16383. [DOI: 10.1021/acs.analchem.2c03543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- Ekaterina Makhneva
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic
| | - Dorota Sklenárová
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic
- CEITEC MU, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic
| | - Julian C. Brandmeier
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Antonín Hlaváček
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 967, 602 00 Brno, Czech Republic
| | - Hans H. Gorris
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic
| | - Petr Skládal
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic
- CEITEC MU, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic
| | - Zdeněk Farka
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic
- CEITEC MU, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic
| |
Collapse
|
5
|
Research on point-of-care tests in outpatient care in Germany: A scoping review and definition of relevant endpoints in evaluation studies. ZEITSCHRIFT FUR EVIDENZ, FORTBILDUNG UND QUALITAT IM GESUNDHEITSWESEN 2022; 174:1-10. [PMID: 36055890 DOI: 10.1016/j.zefq.2022.06.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 03/14/2022] [Accepted: 06/13/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND The fast turnaround time and user-friendliness of point-of-care tests (POCTs) offer a great potential to improve outpatient health care where clinical decisions have to be made during the physician-patient encounter and time resources are limited. The aim of this scoping review is to describe the extent and nature as well as gaps in German research activities on POCT in outpatient care. In addition, we define research endpoints that should be addressed in the comprehensive evaluation of POCTs targeted for outpatient care. METHODS We performed a scoping review with a systematic literature search in Medline (via PubMed), Scopus, Web of Science, Cochrane library and Google Scholar for German publications on POCT with relevance to German outpatient care published from January 2005 to November 2020. RESULTS Our literature search identified 2,200 unique records. After literature selection 117 articles were included in this scoping review. Just over half of the articles (67/117, 57.3%) were primary research studies with original data, while one third of all the studies (33.3%) were secondary research articles (e.g., review articles). The remaining articles were clinical recommendations / position papers (7/117, 6.0%) and other types of articles (3.4%). The majority of articles focused on POCT use in infectious diseases (44/117, 37.6%), diabetic syndromes (15.4%), cardiac disease (12.0%) or coagulopathies and thrombosis (10.3%), while the remaining articles did not specify the disease (13.7%) or investigated other diseases (11.1%). Similar to international studies, most primary research studies investigated the diagnostic performance of POCT (e.g., sensitivity, specificity). Evidence beyond diagnostic accuracy remains scarce, such as the impact on therapeutic decisions and practice routines, clinical effectiveness, and user perspectives. In line with this, interventional studies (such as RCTs) on the effectiveness of POCT use in German outpatient care are limited. We define six endpoint domains that should be addressed in the evaluation of POCTs targeted for outpatient care: (i) diagnostic performance, (ii) clinical performance, (iii) time and costs, (iv) impact on clinical routines / processes, (v) perspectives of medical professionals and patients, and (vi) broader aspects. CONCLUSION There is considerable research activity on POCTs targeted for use in outpatient care in Germany. Data on their potential benefits beyond diagnostic accuracy is often lacking and should be addressed in future POCT research studies.
Collapse
|
6
|
Lim WY, Lan BL, Ramakrishnan N. Emerging Biosensors to Detect Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2): A Review. BIOSENSORS 2021; 11:bios11110434. [PMID: 34821650 PMCID: PMC8615996 DOI: 10.3390/bios11110434] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 10/09/2021] [Accepted: 10/14/2021] [Indexed: 05/07/2023]
Abstract
Coronavirus disease (COVID-19) is a global health crisis caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Real-time reverse transcriptase-polymerase chain reaction (RT-PCR) is the gold standard test for diagnosing COVID-19. Although it is highly accurate, this lab test requires highly-trained personnel and the turn-around time is long. Rapid and inexpensive immuno-diagnostic tests (antigen or antibody test) are available, but these point of care (POC) tests are not as accurate as the RT-PCR test. Biosensors are promising alternatives to these rapid POC tests. Here we review three types of recently developed biosensors for SARS-CoV-2 detection: surface plasmon resonance (SPR)-based, electrochemical and field-effect transistor (FET)-based biosensors. We explain the sensing principles and discuss the advantages and limitations of these sensors. The accuracies of these sensors need to be improved before they could be translated into POC devices for commercial use. We suggest potential biorecognition elements with highly selective target-analyte binding that could be explored to increase the true negative detection rate. To increase the true positive detection rate, we suggest two-dimensional materials and nanomaterials that could be used to modify the sensor surface to increase the sensitivity of the sensor.
Collapse
|
7
|
Johannsen B, Karpíšek M, Baumgartner D, Klein V, Bostanci N, Paust N, Früh SM, Zengerle R, Mitsakakis K. One-step, wash-free, bead-based immunoassay employing bound-free phase detection. Anal Chim Acta 2021; 1153:338280. [DOI: 10.1016/j.aca.2021.338280] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 01/14/2021] [Accepted: 01/31/2021] [Indexed: 12/28/2022]
|
8
|
Wang J, Guo J, Zhang J, Zhang W, Zhang Y. RNA aptamer-based electrochemical aptasensor for C-reactive protein detection using functionalized silica microspheres as immunoprobes. Biosens Bioelectron 2017; 95:100-105. [PMID: 28431362 DOI: 10.1016/j.bios.2017.04.014] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2017] [Revised: 03/27/2017] [Accepted: 04/12/2017] [Indexed: 01/11/2023]
Abstract
C-reactive protein (CRP) is a widely accepted biomarker of cardiovascular disease and inflammation. In this study, a RNA aptamer-based electrochemical sandwich type aptasensor for CRP detection was described using the functionalized silica microspheres as immunoprobes. Silica microspheres (Si MSs), which have good monodispersity and uniform shape, were firstly synthesized. The silica microspheres functionlized with gold nanoparticles (Au NPs) provided large surface area for immobilizing signal molecules (Zinc ions, Zn2+) and antibodies (Ab). RNA aptamers, which were specific recognized to CRP, were assembled on the surface of Au NPs modified electrode via gold-sulfur affinity. In the presence of CRP, a sandwich structure of aptamer-CRP-immunoprobe was formed. Square wave voltammetry (SWV) was employed to record the sensing signal, and a clearly reductive peak corresponding to Zn2+ at about -1.16V (vs. SCE) was obtained. Under optimal conditions, the aptasensor showed wide linear range (0.005ngmL-1 to 125ngmL-1) and low detection limit (0.0017ngmL-1 at a signal-to-noise ratio of 3). Some possible interfering substance was also investigated, and the results obtained showed that the aptasensor possessed good selectivity. When the aptasensor was applied to real serum samples analysis, the satisfied results were obtained, indicating that the aptasensor possessed potential real application ability.
Collapse
Affiliation(s)
- Junchun Wang
- College of Chemistry and Materials Science, the Key Laboratory of Functional Molecular Solids, Ministry of Education, Anhui Key Laboratory of Chem-Biosensing, Anhui Normal University, Wuhu 241000, People's Republic of China
| | - Jinjin Guo
- College of Chemistry and Materials Science, the Key Laboratory of Functional Molecular Solids, Ministry of Education, Anhui Key Laboratory of Chem-Biosensing, Anhui Normal University, Wuhu 241000, People's Republic of China
| | - Junjun Zhang
- College of Chemistry and Materials Science, the Key Laboratory of Functional Molecular Solids, Ministry of Education, Anhui Key Laboratory of Chem-Biosensing, Anhui Normal University, Wuhu 241000, People's Republic of China
| | - Wenjuan Zhang
- College of Chemistry and Materials Science, the Key Laboratory of Functional Molecular Solids, Ministry of Education, Anhui Key Laboratory of Chem-Biosensing, Anhui Normal University, Wuhu 241000, People's Republic of China
| | - Yuzhong Zhang
- College of Chemistry and Materials Science, the Key Laboratory of Functional Molecular Solids, Ministry of Education, Anhui Key Laboratory of Chem-Biosensing, Anhui Normal University, Wuhu 241000, People's Republic of China.
| |
Collapse
|