1
|
Gialain IO, Gantier-Takano MK, Silva LFRD, Roscoe MG, Pinhata-Baptista OH, Meira JBC, Fok ASL. A finite element study on the risk of bone loss around posterior short implants in an atrophic mandible. J Prosthodont Res 2025; 69:110-119. [PMID: 39019591 DOI: 10.2186/jpr.jpr_d_24_00003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/19/2024]
Abstract
PURPOSE This study aimed to evaluate the risk of bone loss around single short molar crown-supporting implants in an atrophic mandible. METHODS Implants of different lengths (L = 4 or 6 mm) and diameters (Ø = 4.1 or 4.8 mm) were placed in the molar area of an atrophic mandible. Additional control mandible models were simulated for 4.1 mm diameter implants (L = 4, 6, 8, and 10 mm). A vertical masticatory load of 200 N was applied to three or six occlusal contact areas (3ca or 6ca) of the prosthetic crown. The bone strain energy density (SED) of 109.6 µJ/mm3 was assumed to be the pathological threshold for cortical bone. The peri-implant bone resorption risk index (PIBRri) was calculated by dividing the maximum SED of the crestal cortical bone by the SED pathological threshold. RESULTS Increasing the implant length from 4 to 6 mm, implant diameter from 4.1 to 4.8 mm, and number of contact areas from 3 to 6 reduced the SED and PIBRri values by approximately 20%, 35%, and 40%, respectively, when comparing pairs of models that isolated a specific variable. All models with 6ca had a low bone resorption risk (PIBRri<0.8), while the Ø4.1 short implant with 3ca had a medium (0.8≤PIBRri≤1.0) or high (PIBRri>1.0) resorption risk. CONCLUSIONS Increasing the diameter or occlusal contact area of a 4 mm short implant in an atrophic mandible resulted in reduced bone resorption risks, similar to or lower than those observed in a regular mandible with standard-length implants.
Collapse
Affiliation(s)
- Ivan Onone Gialain
- School of Dentistry, Department of Biomaterials and Oral Biology, University of São Paulo, São Paulo, Brazil
- University of Cuiabá, Cuiabá, Brazil
| | | | | | - Marina Guimarães Roscoe
- School of Dentistry, Department of Biomaterials and Oral Biology, University of São Paulo, São Paulo, Brazil
| | - Otavio Henrique Pinhata-Baptista
- Dentistry Division of the Military Hospital of São Paulo Area and School of Dentistry, Department of Stomatology, University of São Paulo, São Paulo, Brazil
| | - Josete Barbosa Cruz Meira
- School of Dentistry, Department of Biomaterials and Oral Biology, University of São Paulo, São Paulo, Brazil
| | - Alex Siu Lun Fok
- Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, USA
| |
Collapse
|
2
|
Soodmand I, Becker AK, Sass JO, Jabs C, Kebbach M, Wanke G, Dau M, Bader R. Heterogeneous material models for finite element analysis of the human mandible bone - A systematic review. Heliyon 2024; 10:e40668. [PMID: 39759346 PMCID: PMC11698920 DOI: 10.1016/j.heliyon.2024.e40668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2024] [Revised: 11/06/2024] [Accepted: 11/22/2024] [Indexed: 01/07/2025] Open
Abstract
Subject-specific finite element (FE) modeling of the mandible bone has recently gained attention for its higher accuracy. A critical modeling factor is including personalized material properties from medical images especially when bone quality has to be respected. However, there is no consensus on the material model for the mandible that realistically estimates the Young's modulus of the bone. Therefore, the present study aims to review FE studies employing heterogeneous material modeling of the human mandible bone, synthesizing these models, investigating their origins, and assessing their risk of bias. A systematic review using PRISMA guidelines was conducted on publications before 1st July 2024, involving PubMed, Scopus, and Web of Science. The search string considered (a) anatomical site (b) modeling strategy, and (c) metrics of interest. Two inclusion and five exclusion criteria were defined. A review of 77 FE studies identified 12 distinct heterogeneous material models, built based on different in vitro or computational methodologies leading to varied performance and highly deviated range of estimated Young's modulus. They are proposed for bones from five different anatomical sites than mandible and for both trabecular and cortical bone domains. The original studies were characterized with a low to medium risk of bias. This review assessed the current state of material modeling for subject-specific FE models in the craniomaxillofacial field. Recommendations are provided to support researchers in selecting density-modulus relationships. Future research should focus on standardizing experimental protocols, validating models through combined simulation and experimental approaches, and investigating the anisotropic behaviour of the mandible bone.
Collapse
Affiliation(s)
- Iman Soodmand
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Ann-Kristin Becker
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Jan-Oliver Sass
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Christopher Jabs
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Maeruan Kebbach
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Gesa Wanke
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Michael Dau
- Department of Oral, Maxillofacial Plastic Surgery, Rostock University Medical Center, Rostock, Germany
| | - Rainer Bader
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
3
|
Özdemir H, Hülagü B. Evaluation with finite element analysis of a ball attachment overdenture prosthesis of a patient. Dent Mater J 2024:2024-252. [PMID: 39710405 DOI: 10.4012/dmj.2024-252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2024]
Abstract
This study aimed to apply finite element analysis (FEA) to simulate the oral environment of a patient with an implant-supported overdenture prosthesis. A 3D mandibular model was created for a 45-year-old female patient from CT images, with mucosal thickness measured at 3 mm on average using ultrasonography. The overdenture prosthesis was scanned with an intraoral scanner and placed onto the 3D mandibular model. Displacement of the prosthesis and von Mises stress values of the implant, surrounding bone tissue, implant-prosthesis components, and mucosa were calculated under various masticatory loads. The study found that anterior mastication generated higher stress compared to unilateral and bilateral mastication. The addition of a third implant significantly reduced stress and improved prosthesis stability, particularly during bilateral mastication.
Collapse
Affiliation(s)
- Hatice Özdemir
- Department of Prosthodontics, Faculty of Dentistry, Atatürk University
| | - Burak Hülagü
- Mechanical Engineering, Faculty of Engineering, Atatürk University
| |
Collapse
|
4
|
Faur CI, Herman A, Leahu I, Megiesan S, Caluian I. Marginal Bone Loss Around the Implant: A Retrospective Analysis of Bone Remodeling Over Five Years of Follow-Up. Cureus 2024; 16:e76228. [PMID: 39720772 PMCID: PMC11668266 DOI: 10.7759/cureus.76228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/22/2024] [Indexed: 12/26/2024] Open
Abstract
INTRODUCTION Bone remodeling around implants in implant-supported rehabilitation is a continuous debate with no consensus in the literature. This study aimed to investigate the implant- and patient-specific factors contributing to marginal bone loss near the implant. MATERIALS AND METHODS We included patients who had implant-supported prosthetic rehabilitation using one implant system, between 2014 and 2018, who had full follow-up documentation and orthopantomography over five years, and who had no unwell-controlled systemic pathologies that may influence bone metabolism. RESULTS Eighty-one patients who received 500 implants met the inclusion criteria. We observed approximately 1 mm of bone resorption at the five-year follow-up, with the first 0.78 mm of them being documented at the three-year follow-up. Adults younger than 60 years old had an increase in bone resorption by approximately 30%. No difference was seen between men and women. However, a slight increase in bone resorption at five years was seen in female patients older than 50 years old than in ones younger than 50 years (by 30%). The narrowest diameter (3.5 mm; p = 0.001) and anterior mandible (p = 0.008) had the highest bone resorptions. Contrarily, with an insertion depth of approximately 1 mm (p = 0.004), the splinted implant prosthesis (p = 0.21) and zirconia material of the prosthesis (p = 0.57) had the lowest bone remodeling. Moreover, patients younger than 60 years and female patients above 50 years had an increased bone resorption. CONCLUSIONS Bone remodeling is a multifactorial process. The treatment planning has to take into consideration both implant- and patient-specific factors.
Collapse
Affiliation(s)
- Cosmin I Faur
- Regina Maria Dental Department, Regina Maria Private Healthcare Network, Bucharest, ROU
| | - Adrian Herman
- Faculty of Medicine and Pharmacy, University of Oradea, Oradea, ROU
- Regina Maria Dental Department, Regina Maria Private Healthcare Network, Bucharest, ROU
| | - Ionut Leahu
- Regina Maria Dental Department, Regina Maria Private Healthcare Network, Bucharest, ROU
| | - Sergiu Megiesan
- Mathematics Department, Imperial College London Alumni, London, GBR
| | - Ionut Caluian
- Regina Maria Dental Department, Regina Maria Private Healthcare Network, Bucharest, ROU
| |
Collapse
|
5
|
Poovarodom P, Rungsiyakull C, Suriyawanakul J, Li Q, Sasaki K, Yoda N, Rungsiyakull P. Effect of customized abutment taper configuration on bone remodeling and peri-implant tissue around implant-supported single crown: A 3D nonlinear finite element study. J Prosthodont 2024; 33:815-823. [PMID: 37767904 DOI: 10.1111/jopr.13776] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 08/24/2023] [Accepted: 09/23/2023] [Indexed: 09/29/2023] Open
Abstract
PURPOSE The optimal configuration of a customized implant abutment plays a crucial role in promoting bone remodeling and maintaining the peri-implant gingival contour. However, the biomechanical effects of abutment configuration on bone remodeling and peri-implant tissue remain unclear. This study aimed to evaluate the influence of abutment taper configurations on bone remodeling and peri-implant tissue. MATERIALS AND METHODS Five models with different abutment taper configurations (10°, 20°, 30°, 40°, and 50°) were analyzed using finite element analysis (FEA) to evaluate the biomechanical responses in peri-implant bone and the hydrostatic pressure in peri-implant tissue. RESULTS The results demonstrated that the rate of increase in bone density was similar in all models. On the other hand, the hydrostatic pressure in peri-implant gingiva revealed significantly different results. Model 10° showed the highest maximum and volume-averaged hydrostatic pressures (69.31 and 4.5 mmHg), whereas Model 30° demonstrated the lowest values (57.83 and 3.88 mmHg) with the lowest excessive pressure area. The area of excessive hydrostatic pressure decreased in all models as the degree of abutment taper increased from 10° to 30°. In contrast, Models 40° and 50° exhibited greater hydrostatic pressure concentration at the cervical region. CONCLUSION In conclusion, the abutment taper configuration had a slight effect on bone remodeling but exerted a significant effect on the peri-implant gingiva above the implant platform via hydrostatic pressure. Significant decreases in greatest and average hydrostatic pressures were observed in the peri-implant tissues of Model 30°. However, the results indicate that implant abutment tapering wider than 40° could result in a larger area of excessive hydrostatic pressure in peri-implant tissue, which could induce gingival recession.
Collapse
Affiliation(s)
- Pongsakorn Poovarodom
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand
| | - Chaiy Rungsiyakull
- Department of Mechanical Engineering, Faculty of Engineering, Chiang Mai University, Muang, Chiang Mai, Thailand
| | - Jarupol Suriyawanakul
- Faculty of Engineering, Department of Mechanical Engineering, Khon Kaen University, Nai Mueang, Thailand
| | - Qing Li
- Faculty of Engineering, School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, Australia
| | - Keiichi Sasaki
- Miyagi University, Taiwa, Japan
- Graduate School of Dentistry, Division of Prosthetic Dentistry, Tohoku University, Sendai, Japan
| | - Nobuhiro Yoda
- Graduate School of Dentistry, Division of Prosthetic Dentistry, Tohoku University, Sendai, Japan
| | - Pimduen Rungsiyakull
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand
| |
Collapse
|
6
|
Soleimani K, Ghasemloonia A, Sudak L. Influence of interstitial fluid pressure, porosity, loading magnitude, and anisotropy in cortical bone adaptation. Comput Biol Med 2024; 181:109026. [PMID: 39168016 DOI: 10.1016/j.compbiomed.2024.109026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Revised: 08/01/2024] [Accepted: 08/11/2024] [Indexed: 08/23/2024]
Abstract
Adaptive elasticity in cortical bone has traditionally been modeled using Strain Energy Density (SED). Recent studies have highlighted the importance of interstitial fluid in bone adaptation, yet no research has quantified the role of interstitial fluid pressure and its effects, specifically incorporating both SED and interstitial fluid pressure in the adaptation process. This study introduces a novel formulation combining theory of porous media and theory of adaptive elasticity that considers both SED and interstitial fluid's pressure in cortical bone adaptation. The formulation is solved using ANSYS Fluent and a MATLAB script, and sensitivity analyses were conducted, analyzing various porosities, loading magnitudes, anisotropic properties of cortical bone, and involvement coefficients of interstitial fluid's pressure. This study reveals that bones with different vascular porosities (PV) tend to achieve similar density distributions under uniform loading over time. This highlights the significant role of interstitial fluid pressure in accelerating the convergence to optimal bone properties, especially in specimens with larger PV porosities. The findings emphasize the importance of fluid pressure in bone remodeling, aligning with previous studies. Furthermore, this study demonstrates that considering transversely isotropic material properties can significantly alter the remodeling configuration compared to isotropic material properties. This highlights the importance of accurately representing the anisotropic nature of cortical bone in models to better predict its adaptive responses. However, aspects such as fluid density variations and bone geometry changes remain unexplored, suggesting directions for future research. Overall, this research enhances the understanding of cortical bone adaptation and its mechanical interactions.
Collapse
Affiliation(s)
- K Soleimani
- Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Alberta, Canada.
| | - A Ghasemloonia
- Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Alberta, Canada
| | - L Sudak
- Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Alberta, Canada.
| |
Collapse
|
7
|
Poovarodom P, Rungsiyakull C, Suriyawanakul J, Li Q, Sasaki K, Yoda N, Rungsiyakull P. Multi-objective optimization of custom implant abutment design for enhanced bone remodeling in single-crown implants using 3D finite element analysis. Sci Rep 2024; 14:15867. [PMID: 38982141 PMCID: PMC11648181 DOI: 10.1038/s41598-024-66807-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2023] [Accepted: 07/04/2024] [Indexed: 07/11/2024] Open
Abstract
The optimal configuration of a customized implant abutment is crucial for bone remodeling and is influenced by various design parameters. This study introduces an optimization process for designing two-piece zirconia dental implant abutments. The aim is to enhance bone remodeling, increase bone density in the peri-implant region, and reduce the risk of late implant failure. A 12-month bone remodeling algorithm subroutine in finite element analysis to optimize three parameters: implant placement depth, abutment taper degree, and gingival height of the titanium base abutment. The response surface analysis shows that implant placement depth and gingival height significantly impact bone density and uniformity. The taper degree has a smaller effect on bone remodeling. The optimization identified optimal values of 1.5 mm for depth, 35° for taper, and 0.5 mm for gingival height. The optimum model significantly increased cortical bone density from 1.2 to 1.937 g/cm3 in 2 months, while the original model reached 1.91 g/cm3 in 11 months. The standard deviation of density showed more uniform bone apposition, with the optimum model showing values 2 to 6 times lower than the original over 12 months. The cancellous bone showed a similar trend. In conclusion, the depth and taper have a significant effect on bone remodeling. This optimized model significantly improves bone density uniformity.
Collapse
Affiliation(s)
- Pongsakorn Poovarodom
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, 50200, Thailand
- Digital Laboratory Innovation, Department of Reconstructive and Rehabilitation Sciences, James B. Edwards College of Dental Medicine, Medical University of South Carolina, Charleston, SC, 29425, USA
| | - Chaiy Rungsiyakull
- Department of Mechanical Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Jarupol Suriyawanakul
- Department of Mechanical Engineering, Faculty of Engineering, Khon Kaen University, Khon Kaen, 40000, Thailand
| | - Qing Li
- Faculty of Engineering, School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW, 2037, Australia
| | - Keiichi Sasaki
- Miyagi University, Taiwa, Miyagi, 981-3298, Japan
- Division of Prosthetic Dentistry, Graduate School of Dentistry, Tohoku University, Sendai, Miyagi, 980-8576, Japan
| | - Nobuhiro Yoda
- Division of Prosthetic Dentistry, Graduate School of Dentistry, Tohoku University, Sendai, Miyagi, 980-8576, Japan
| | - Pimduen Rungsiyakull
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, 50200, Thailand.
| |
Collapse
|
8
|
Mishra D, Basu B. Biomechanical analysis of peri-prosthetic bone response to hybrid threaded zirconia dental implants: An in silico model. J Mech Behav Biomed Mater 2024; 150:106310. [PMID: 38128471 DOI: 10.1016/j.jmbbm.2023.106310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 11/29/2023] [Accepted: 12/03/2023] [Indexed: 12/23/2023]
Abstract
The biomechanical response of mandibular bone determines primary stability and concomitant osseointegration of dental implants. This study explores the impact of nature of loading and bone conditions on biomechanical response of hybrid threaded single-piece zirconia dental implants. To develop such understanding, three implants (SQ_V, V_BUT, and V_V), with different combinations of threads, square (SQ), buttress (BUT), and triangular (V), have been investigated. Finite Element Analysis (FEA) was carried out to simulate implantation at the molar position of mandible of varying densities under axial (≤500 N) and oblique (118.2 N) loadings. Patient-specific bone conditions (for a wider population) were considered by scaling the density and the elastic modulus of mandible to represent, 'weak', 'healthy', and 'strong' bone conditions. FEA results revealed that SQ_V and V_BUT implants exhibited a better biomechanical response without significant variation (<0.5%) in von Mises stress, regardless of bone density and axial loadings. These implants are predicted to perform with clinically acceptable factor of safety under investigated implantation scenarios, whereas V_BUT implant showed a larger variation (∼±12%). FEA simulation with oblique loading further validated such results. The 'weak' bone conditions resulted in maximum peri-implant microstrain, whereas 'strong and healthy' bone exhibited values close to the permissible range of physiological remodeling. The maximum micromotion (∼12.3 ± 6.2 μm for 'weak' bone) at bone-implant interface suggested that implant loosening and impaired osseointegration will not occur in any of selected virtual implantation cases. Both SQ_V and V_BUT implants will be considered further in implant development, involving manufacturing and product prototype validation. Taken together, the critical analysis of FEA results indicates a significant impact of bone density and distinct combinations of external threads on the biomechanical responses, in both the implant and the surrounding bone.
Collapse
Affiliation(s)
- Deepa Mishra
- Laboratory for Biomaterials, Materials Research Centre, Indian Institute of Science, Bengaluru, 560012, India
| | - Bikramjit Basu
- Laboratory for Biomaterials, Materials Research Centre, Indian Institute of Science, Bengaluru, 560012, India; Centre for Biosystems Science and Engineering, Indian Institute of Science, Bangalore, 560012, India.
| |
Collapse
|
9
|
Xu W, Shen J, Li K, Zhao T, Xie B, Chen J, He Y. A mechanical and three-dimensional finite element study of the optimum tooth sectioning depth during the extraction of low-level horizontally impacted mandibular third molar. Odontology 2024; 112:242-249. [PMID: 37273122 DOI: 10.1007/s10266-023-00822-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Accepted: 05/15/2023] [Indexed: 06/06/2023]
Abstract
The present study aims to determine the optimum sectioning depth for the extraction of low-level horizontally impacted mandibular third molar (LHIM3M) using mechanical and finite element analysis. One hundred and fifty extracted mandibular third molars were randomly divided into three groups: 1, 2 or 3 mm of tooth tissue was retained at the bottom of the crown. The breaking force of teeth was tested in a universal strength testing machine. The fracture surface was observed and the type of tooth breakage was recorded. According to the three groups, corresponding 3D finite element models were created. The breaking force obtained in the mechanical study was, respectively, applied and the stress and strain of the teeth and surrounding tissues were analysed. Breaking force decreased as sectioning depth increased. The 2 mm group produced the lowest rate of incomplete breakage (10%). In the 2 mm model, the stresses were evenly distributed in the tooth tissue at the bottom of the fissure, and the maximal stress was located in the tissue close to the root segment. The maximum values of stresses in the bone and of strains in the periodontal ligament of the second molar and bone were lower in the 1 mm model than in other models. Their distribution was similar in the three models. A sectioning depth of 1 mm group saves labour during the extraction of LHIM3M, compared to 2 and 3 mm; 2 mm might be the appropriate sectioning depth in terms of breakage shapes.
Collapse
Affiliation(s)
- Wei Xu
- Department of Oral and Maxillofacial Surgery, the Affiliated Stomatological Hospital of Southwest Medical University, Jiangyangnanlu 2, Luzhou, 646000, China
- Oral and Maxillofacial Reconstruction and Regeneration of Luzhou Key Laboratory, Southwest Medical University, Luzhou, 646000, China
| | - Jie Shen
- Department of Oral and Maxillofacial Surgery, the Affiliated Stomatological Hospital of Southwest Medical University, Jiangyangnanlu 2, Luzhou, 646000, China
- Oral and Maxillofacial Reconstruction and Regeneration of Luzhou Key Laboratory, Southwest Medical University, Luzhou, 646000, China
| | - Kuncai Li
- Department of Oral and Maxillofacial Surgery, the Affiliated Stomatological Hospital of Southwest Medical University, Jiangyangnanlu 2, Luzhou, 646000, China
- Oral and Maxillofacial Reconstruction and Regeneration of Luzhou Key Laboratory, Southwest Medical University, Luzhou, 646000, China
| | - Tianqi Zhao
- Department of Oral and Maxillofacial Surgery, the Affiliated Stomatological Hospital of Southwest Medical University, Jiangyangnanlu 2, Luzhou, 646000, China
- Oral and Maxillofacial Reconstruction and Regeneration of Luzhou Key Laboratory, Southwest Medical University, Luzhou, 646000, China
| | - Binqing Xie
- Department of Oral and Maxillofacial Surgery, the Affiliated Stomatological Hospital of Southwest Medical University, Jiangyangnanlu 2, Luzhou, 646000, China
- Oral and Maxillofacial Reconstruction and Regeneration of Luzhou Key Laboratory, Southwest Medical University, Luzhou, 646000, China
| | - Junliang Chen
- Department of Oral and Maxillofacial Surgery, the Affiliated Stomatological Hospital of Southwest Medical University, Jiangyangnanlu 2, Luzhou, 646000, China.
- Oral and Maxillofacial Reconstruction and Regeneration of Luzhou Key Laboratory, Southwest Medical University, Luzhou, 646000, China.
| | - Yun He
- Department of Oral and Maxillofacial Surgery, the Affiliated Stomatological Hospital of Southwest Medical University, Jiangyangnanlu 2, Luzhou, 646000, China.
- Oral and Maxillofacial Reconstruction and Regeneration of Luzhou Key Laboratory, Southwest Medical University, Luzhou, 646000, China.
| |
Collapse
|
10
|
Zhong J, Shibata Y, Wu C, Watanabe C, Chen J, Zheng K, Hu J, Swain MV, Li Q. Functional non-uniformity of periodontal ligaments tunes mechanobiological stimuli across soft- and hard-tissue interfaces. Acta Biomater 2023; 170:240-249. [PMID: 37634832 DOI: 10.1016/j.actbio.2023.08.047] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 08/09/2023] [Accepted: 08/22/2023] [Indexed: 08/29/2023]
Abstract
The bone-periodontal ligament-tooth (BPT) complex is a unique mechanosensing soft-/hard-tissue interface, which governs the most rapid bony homeostasis in the body responding to external loadings. While the correlation between such loading and alveolar bone remodelling has been widely recognised, it has remained challenging to investigate the transmitted mechanobiological stimuli across such embedded soft-/hard-tissue interfaces of the BPT complex. Here, we propose a framework combining three distinct bioengineering techniques (i, ii, and iii below) to elucidate the innate functional non-uniformity of the PDL in tuning mechanical stimuli to the surrounding alveolar bone. The biphasic PDL mechanical properties measured via nanoindentation, namely the elastic moduli of fibres and ground substance at the sub-tissue level (i), were used as the input parameters in an image-based constitutive modelling framework for finite element simulation (ii). In tandem with U-net deep learning, the Gaussian mixture method enabled the comparison of 5195 possible pseudo-microstructures versus the innate non-uniformity of the PDL (iii). We found that the balance between hydrostatic pressure in PDL and the strain energy in the alveolar bone was maintained within a specific physiological range. The innate PDL microstructure ensures the transduction of favourable mechanobiological stimuli, thereby governing alveolar bone homeostasis. Our outcomes expand current knowledge of the PDL's mechanobiological roles and the proposed framework can be adopted to a broad range of similar soft-/hard- tissue interfaces, which may impact future tissue engineering, regenerative medicine, and evaluating therapeutic strategies. STATEMENT OF SIGNIFICANCE: A combination of cutting-edge technologies, including dynamic nanomechanical testing, high-resolution image-based modelling and machine learning facilitated computing, was used to elucidate the association between the microstructural non-uniformity and biomechanical competence of periodontal ligaments (PDLs). The innate PDL fibre network regulates mechanobiological stimuli, which govern alveolar bone remodelling, in different tissues across the bone-PDL-tooth (BPT) interfaces. These mechanobiological stimuli within the BPT are tuned within a physiological range by the non-uniform microstructure of PDLs, ensuring functional tissue homeostasis. The proposed framework in this study is also applicable for investigating the structure-function relationship in broader types of fibrous soft-/hard- tissue interfaces.
Collapse
Affiliation(s)
- Jingxiao Zhong
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Yo Shibata
- Department of Biomaterials and Engineering, Showa University School of Dentistry, Tokyo, Japan
| | - Chi Wu
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Chie Watanabe
- Department of Biomaterials and Engineering, Showa University School of Dentistry, Tokyo, Japan
| | - Junning Chen
- College of Engineering, Mathematics and Physical Sciences, University of Exeter, Exeter, UK
| | - Keke Zheng
- Institute for Mechanical, Process and Energy Engineering, School of Engineering and Physical Sciences, Heriot Watt University, Edinburgh, UK
| | - Jingrui Hu
- College of Engineering, Mathematics and Physical Sciences, University of Exeter, Exeter, UK
| | - Michael V Swain
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Qing Li
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia.
| |
Collapse
|
11
|
Monje A, Roccuzzo A, Buser D, Wang HL. Influence of buccal bone wall thickness on the peri-implant hard and soft tissue dimensional changes: A systematic review. Clin Oral Implants Res 2023; 34 Suppl 26:8-27. [PMID: 37750522 DOI: 10.1111/clr.14177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 12/16/2022] [Accepted: 12/17/2022] [Indexed: 09/27/2023]
Abstract
BACKGROUND The significance on the association between the peri-implant bucco-lingual dimension (BLD) at the stage of implant placement and the occurrence of biological and esthetic complications is yet unknown. MATERIAL AND METHODS Systematic screening of electronic sources was carried out to identify clinical and preclinical studies reporting on the baseline BLD and/or buccal bone thickness (BBT) values. A secondary objective was to assess the effect of simultaneous grafting at sites with deficient or no buccal bone wall (BBW) at baseline. The primary outcome variables were BBT, BLD, and buccal vertical bone loss (VBL) at re-evaluation. Moreover, radiographic, clinical, and patient-reported outcome measures (PROMs) were evaluated. RESULTS Overall, 12 clinical and four preclinical studies met the inclusion criteria. Inconsistencies were found in defining the critical BBT across the clinical and preclinical data evaluated. The clinical evidence demonstrated that during healing, dimensional changes occur in the alveolar bone and in the BBW that may compromise the integrity of the peri-implant bone, leading to VBL and mucosal recession (MR), particularly in scenarios exhibiting a thin BBW. The preclinical evidence validated the fact that implants placed in the presence of a thin BBW, are more prone to exhibit major dimensional changes and VBL. Moreover, the clinical data supported that, in scenarios where dehiscence-type defects occur and are left for spontaneous healing, greater VBL and MR together with the occurrence of biologic complications are expected. Furthermore, the augmentation of dehiscence-type defects is associated with hard and soft tissue stability. PROMs were not reported. CONCLUSIONS Dimensional changes occur as result of implant placement in healed ridges that may lead to instability of the peri-implant hard and soft tissues. Sites presenting a thin BBW are more prone to exhibit major changes that may compromise the integrity of the buccal bone and may lead to biologic and esthetic complications.
Collapse
Affiliation(s)
- Alberto Monje
- Department of Periodontology and Oral Medicine, University of Michigan, Ann Arbor, Michigan, USA
- Department of Periodontology, Universitat Internacional de Catalunya, Barcelona, Spain
- Department of Periodontology, University of Bern, Bern, Switzerland
| | - Andrea Roccuzzo
- Department of Periodontology, University of Bern, Bern, Switzerland
- Department of Oral Maxillofacial Surgery, Copenaghen University Hospital (Rigshospitalet), Copenhagen, Denmark
| | - Daniel Buser
- School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Hom-Lay Wang
- Department of Periodontology and Oral Medicine, University of Michigan, Ann Arbor, Michigan, USA
| |
Collapse
|
12
|
Wach T, Hadrowicz P, Trybek G, Michcik A, Kozakiewicz M. Is Corticalization in Radiographs Related to a Higher Risk of Bone Loss around Dental Implants in Smoking Patients? A 5-Year Observation of Radiograph Bone-Texture Changes. J Clin Med 2023; 12:5351. [PMID: 37629393 PMCID: PMC10456057 DOI: 10.3390/jcm12165351] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 07/20/2023] [Accepted: 07/28/2023] [Indexed: 08/27/2023] Open
Abstract
BACKGROUND Currently, the topic of dental implants is widely researched. However, still compromising are the factors that can affect implant loss as a consequence of marginal bone loss. One of the factors is smoking, which has a devastating effect on human health and bone structure. Oral health and jaw condition are also negatively affected by smoking. The aim of this study was to evaluate the peri-implant jawbone corticalization phenomenon in tobacco smokers. METHODS A total of 2196 samples from 768 patients with an implant in the neck area were checked, and texture features were analyzed. The corticalization phenomenon was investigated. All analyses were performed in MaZda Software. The influence of corticalization was investigated as a factor on bone structure near the implant neck. The statistical analysis included a feature distribution evaluation, mean (t-test) or median (W-test) comparison, analysis of regression and one-way analysis of variance or Kruskal-Wallis test as no normal distribution or between-group variance was indicated for the significant differences in the investigated groups. Detected differences or relationships were assumed to be statistically significant when p < 0.05. RESULTS The research revealed that MBL was correlated with smoking after 5 years (0.42 mm ± 1.32 mm 0 mm ± 1.25 mm), the Corticalization Index was higher in the smoker group on the day of surgery, and it became higher after 5y of observation (185.98 ± 90.8 and 243.17 ± 155.47). The implant-loss frequency was higher in the group of smokers, too, compared to non-smokers (6.74% and 2.87%). The higher the torque value during the implant placement, the higher the Corticalization Phenomenon Index. CONCLUSIONS The research revealed a correlation between smoking and changes in bone structure in radio textures near the implants. The corticalization phenomenon is important, may be detected immediately after implant placement and may be one of the indicators of the implant success rate.
Collapse
Affiliation(s)
- Tomasz Wach
- Department of Maxillofacial Surgery, Medical University of Lodz, 113 Żeromskiego Str., 90-549 Lodz, Poland;
| | - Piotr Hadrowicz
- Department of Otolaryngology, Hospital in Sosnowiec, Zegadłowicza 3, 41-200 Sosnowiec, Poland;
| | - Grzegorz Trybek
- Department of Oral Surgery, Pomeranian Medical University in Szczecin, 70-111 Szczecin, Poland;
- 4th Military Clinical Hospital in Wroclaw, ul. Rudolfa Weigla 5, 50-981 Wroclaw, Poland
| | - Adam Michcik
- Department of Maxillofacial Surgery, Medical University of Gdansk, 80-210 Gdańsk, Poland;
| | - Marcin Kozakiewicz
- Department of Maxillofacial Surgery, Medical University of Lodz, 113 Żeromskiego Str., 90-549 Lodz, Poland;
| |
Collapse
|
13
|
Monje A, Roccuzzo A, Buser D, Wang HL. Significance of buccal bone wall thickness on the fate of peri-implant hard and soft tissues: A systematic review. Clin Oral Implants Res 2023; 34:157-176. [PMID: 36626118 DOI: 10.1111/clr.14029] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 12/16/2022] [Accepted: 12/17/2022] [Indexed: 01/11/2023]
Abstract
BACKGROUND The significance of the association between the peri-implant buccolingual dimension (BLD) at the stage of implant placement and the occurrence of biological and esthetic complications is yet unknown. MATERIAL AND METHODS Systematic screening of electronic sources was carried out to identify clinical and preclinical studies reporting on the baseline BLD and/or buccal bone thickness (BBT) values. A secondary objective was to assess the effect of simultaneous grafting at sites with deficient or no buccal bone wall (BBW) at baseline. The primary outcome variables were BBT, BLD, and vertical bone loss (VBL) at re-evaluation. Moreover, radiographic, clinical- and patient-reported outcome measures (PROMs) were evaluated. RESULTS Overall, 12 clinical and four preclinical studies met the inclusion criteria. The clinical evidence demonstrated that during healing, dimensional changes occur in the alveolar bone and in the BBW that may compromise the integrity of bone around a dental implant. The preclinical evidence validated the fact that implants placed in the presence of thin BBW are more prone to exhibit major dimensional changes. Moreover, the clinical and preclinical data supported that in scenarios where dehiscence-type defects are left for spontaneous healing, greater VBL and mucosal recession (MR) together with the occurrence of biologic complications are expected. Furthermore, the augmentation of dehiscence-type defects is associated with hard and soft tissue stability. CONCLUSIONS Dimensional changes occur as a result of implant placement in healed ridges that may lead to VBL and MR. Thin BBW (≲2 mm) are prone to exhibit major postchanges that may compromise the integrity of the buccal bone, biologic and esthetic complications.
Collapse
Affiliation(s)
- Alberto Monje
- Department of Periodontology and Oral Medicine, University of Michigan, Ann Arbor, Michigan, USA.,Department of Periodontology, Universitat Internacional de Catalunya, Barcelona, Spain.,Department of Periodontology, University of Bern, Bern, Switzerland
| | - Andrea Roccuzzo
- Department of Periodontology, University of Bern, Bern, Switzerland
| | - Daniel Buser
- School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Hom-Lay Wang
- Department of Periodontology and Oral Medicine, University of Michigan, Ann Arbor, Michigan, USA
| |
Collapse
|
14
|
Li Q, Zhang X, Wang C, Hu H, Tang Z, Fan Y. Biomechanical evaluation of customized root implants in alveolar bone: A comparative study with traditional implants and natural teeth. J Prosthodont 2023; 32:e30-e40. [PMID: 35950785 DOI: 10.1111/jopr.13590] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Accepted: 08/02/2022] [Indexed: 11/28/2022] Open
Abstract
PURPOSE To compare and evaluate density changes in alveolar bones and biomechanical responses including stress/strain distributions around customized root implants (CRIs), traditional implants, and natural teeth. MATERIALS AND METHODS A three-dimensional finite element model of the maxillary dentition defect, CRI models, traditional restored implant models, and natural teeth with periodontal tissue models were established. The chewing load of the central incisor, the traditional implant, and the CRI was 100N, and the load direction was inclined by 11° in the sagittal plane. According to the bone remodeling numerical algorithm, the bone mineral density and distribution were calculated and predicted. In addition, animal experiments were performed to verify the feasibility of the implant design. The results of the simulation calculations were compared with animal experimental data in vivo to verify their validity. RESULTS No significant differences in bone mineral density and stress/strain distribution were found between the CRI and traditional implant models. The animal experimental results (X-ray images and histological staining) were consistent with the numerical simulated results. CONCLUSIONS CRIs were more similar to traditional implants than to natural teeth in terms of biomechanical and biological evaluation. Considering the convenience of clinical application, this biomechanical evaluation provides basic theoretical support for further applications of CRI.
Collapse
Affiliation(s)
- Qing Li
- Center of Digital Dentistry, Peking University School and Hospital of Stomatology, Beijing, China.,Second Clinical Division, Peking University School and Hospital of Stomatology, Beijing, China.,National Center of Stomatology and National Clinical Research Center for Oral Diseases, Beijing, China.,National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, China
| | - Xinyue Zhang
- Center of Digital Dentistry, Peking University School and Hospital of Stomatology, Beijing, China.,National Center of Stomatology and National Clinical Research Center for Oral Diseases, Beijing, China.,National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, China
| | - Chao Wang
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, Beijing, China
| | - Hongcheng Hu
- Second Clinical Division, Peking University School and Hospital of Stomatology, Beijing, China.,National Center of Stomatology and National Clinical Research Center for Oral Diseases, Beijing, China.,National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, China
| | - Zhihui Tang
- Second Clinical Division, Peking University School and Hospital of Stomatology, Beijing, China.,National Center of Stomatology and National Clinical Research Center for Oral Diseases, Beijing, China.,National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, China
| | - Yubo Fan
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, Beijing, China
| |
Collapse
|
15
|
Zapata JM, Leal E, Hunter R, de Souza RF, Borie E. Biomechanical Behavior of Narrow Dental Implants Made with Aluminum- and Vanadium-Free Alloys: A Finite Element Analysis. MATERIALS (BASEL, SWITZERLAND) 2022; 15:8903. [PMID: 36556709 PMCID: PMC9786661 DOI: 10.3390/ma15248903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 09/07/2022] [Accepted: 09/14/2022] [Indexed: 06/17/2023]
Abstract
Titanium (Ti) alloys used for narrow dental implants usually contain aluminum (Al) and vanadium (V) for improved resistance. However, those elements are linked to possible cytotoxic effects. Thus, this study evaluated the biomechanical behavior of narrow dental implants made with Al- and V-free Ti alloys by the finite element method. A virtual model of a partially edentulous maxilla received single implants (diameter: 2.7 and 2.9 mm; length: 10 mm) at the upper lateral incisor area, with respective abutments and porcelain-fused-to-metal crowns. Simulations were performed for each implant diameter and the following eight alloys (and elastic moduli): (1) Ti-6Al-4V (control; 110 GPa), (2) Ti-35Nb-5Sn-6Mo-3Zr (85 GPa), (3) Ti-13Nb-13Zr (77 GPa), (4) Ti-15Zr (113 GPa), (5) Ti-8Fe-5Ta (120 GPa), (6) Ti-26.88Fe-4Ta (175 GPa), (7) TNTZ-2Fe-0.4O (107 GPa), and (8) TNTZ-2Fe-0.7O (109 GPa). The implants received a labially directed total static load of 100 N at a 45° angle relative to their long axis. Parameters for analysis included the maximum and minimum principal stresses for bone, and von Mises equivalent stress for implants and abutments. Ti-26.88Fe-4Ta reaches the lowest maximum (57 MPa) and minimum (125 MPa) principal stress values, whereas Ti-35Nb-5Sn-6Mo-3Zr (183 MPa) and Ti-13Nb-13Zr (191 MPa) models result in the highest principal stresses (the 2.7 mm model surpasses the threshold for bone overload). Implant diameters affect von Mises stresses more than the constituent alloys. It can be concluded that the narrow implants made of the Ti-26.88Fe-4Ta alloy have the most favorable biomechanical behavior, mostly by mitigating stress on peri-implant bone.
Collapse
Affiliation(s)
- José Manuel Zapata
- Master in Dental Sciences Program, Universidad de La Frontera, Temuco PC 4811230, Chile
| | - Eduardo Leal
- Mechanical Engineering Department, Universidad de La Frontera, Temuco PC 4811230, Chile
| | - Renato Hunter
- Mechanical Engineering Department, Universidad de La Frontera, Temuco PC 4811230, Chile
| | - Raphael Freitas de Souza
- Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal, QC H3A 0G4, Canada
| | - Eduardo Borie
- CICO Research Centre, Integral Dentistry Department, Dental School, Universidad de La Frontera, Temuco PC 4811230, Chile
| |
Collapse
|
16
|
Onone Gialain I, Folmer Rodrigues da Silva L, Kasumi Gantier Takano M, Yagüe Ballester R, Guimarães Roscoe M, Barbosa Cruz Meira J. Peri-implant bone resorption risk of anterior maxilla narrow single implants: a finite-element analysis. Biomater Investig Dent 2022; 9:92-100. [PMID: 36325029 PMCID: PMC9621276 DOI: 10.1080/26415275.2022.2135516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Statement of the problem: Narrow implants have been recommended in high esthetic demand regions to ensure greater buccal bone thickness (BBT) and minimize soft-tissue recession due to insufficient bone support. However, a limited area of bone-implant interface can increase the risk of peri-implant bone resorption due to occlusal forces. Purpose: This article encourages the use of evidence-based finite element analysis to optimize the aesthetic outcomes in maxillary lateral incisor single-supported implant crown by accurate biomechanical planning. This study aimed to analyze the best implant dimensions that would preserve the maximum BBT and avoid peri-implant bone resorption due to occlusal forces. Materials and methods: A maxilla segment was constructed based on anthropological measurements. Four implant diameters (Ø = 3.25; 3.50; 3.75 or 4.00 mm) and two lengths (L = 10 or 13 mm) were simulated. The occlusal force parameters were defined to simulate clinical conditions. The bone resorption risk analysis was based on Frost's mechanostat theory altering the strain output to strain energy density (SED). The peri-implant bone resorption risk indexes (PIBRri) were calculated by dividing the average of the top ten SED elements of the cortical and trabecular buccal wall by the pathologic resorption limit for each bone. Results: For trabecular bone, only the model Ø4.00L13 exhibited a low PIBRri. For cortical bone, all models presented a low PIBRri, except for models Ø3.25. Conclusion: The selection of a 3.25 mm dental implant to preserve a 2 mm BBT should be avoided since it generates a high peri-implant bone resorption risk induced by occlusal overload.
Collapse
Affiliation(s)
- Ivan Onone Gialain
- School of Dentistry, Department of Biomaterials and Oral Biology, University of São Paulo, São Paulo, Brazil
| | | | - Marlene Kasumi Gantier Takano
- “Finite element analysis in Dentistry” Course, School of Dentistry, Department of Biomaterials and Oral Biology, University of São Paulo, São Paulo, Brazil
| | - Rafael Yagüe Ballester
- School of Dentistry, Department of Biomaterials and Oral Biology, University of São Paulo, São Paulo, Brazil
| | - Marina Guimarães Roscoe
- School of Dentistry, Department of Biomaterials and Oral Biology, University of São Paulo, São Paulo, Brazil
| | - Josete Barbosa Cruz Meira
- School of Dentistry, Department of Biomaterials and Oral Biology, University of São Paulo, São Paulo, Brazil,CONTACT Josete Barbosa Cruz Meira Department of Biomaterials and Oral Biology, University of São Paulo, School of Dentistry, Av. Prof. Lineu Prestes, 2227, São Paulo, 05508-000, Brazil
| |
Collapse
|
17
|
Ghosh R, Chanda S, Chakraborty D. Application of finite element analysis to tissue differentiation and bone remodelling approaches and their use in design optimization of orthopaedic implants: A review. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3637. [PMID: 35875869 DOI: 10.1002/cnm.3637] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 06/26/2022] [Accepted: 07/21/2022] [Indexed: 06/15/2023]
Abstract
Post-operative bone growth and long-term bone adaptation around the orthopaedic implants are simulated using the mechanoregulation based tissue-differentiation and adaptive bone remodelling algorithms, respectively. The primary objective of these algorithms was to assess biomechanical feasibility and reliability of orthopaedic implants. This article aims to offer a comprehensive review of the developments in mathematical models of tissue-differentiation and bone adaptation and their applications in studies involving design optimization of orthopaedic implants over three decades. Despite the different mechanoregulatory models developed, existing literature confirm that none of the models can be highly regarded or completely disregarded over each other. Not much development in mathematical formulations has been observed from the current state of knowledge due to the lack of in vivo studies involving clinically relevant animal models, which further retarded the development of such models to use in translational research at a fast pace. Future investigations involving artificial intelligence (AI), soft-computing techniques and combined tissue-differentiation and bone-adaptation studies involving animal subjects for model verification are needed to formulate more sophisticated mathematical models to enhance the accuracy of pre-clinical testing of orthopaedic implants.
Collapse
Affiliation(s)
- Rajdeep Ghosh
- Composite Structures and Fracture Mechanics Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam, India
| | - Souptick Chanda
- Biomechanics and Simulations Laboratory, Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati, Assam, India
- Mehta Family School of Data Science and Artificial Intelligence, Indian Institute of Technology Guwahati, Guwahati, Assam, India
| | - Debabrata Chakraborty
- Composite Structures and Fracture Mechanics Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam, India
| |
Collapse
|
18
|
Poovarodom P, Rungsiyakull C, Suriyawanakul J, Li Q, Sasaki K, Yoda N, Rungsiyakull P. Effect of implant placement depth on bone remodeling on implant-supported single zirconia abutment crown: A 3D finite element study. J Prosthodont Res 2022; 67:278-287. [PMID: 35934782 DOI: 10.2186/jpr.jpr_d_22_00054] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE This study aimed to evaluate the influence of subcrestal implant placement depth on bone remodeling using time-dependent finite element analysis (FEA) with a bone-remodeling algorithm over 12 months. METHODS Seven models of different subcrestal implant placement depths (0, 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 mm) were analyzed using FEA to evaluate the biomechanical responses in the bone and implant, including von Mises equivalent stress, strain energy density (SED), and overloading elements. SED was used as a mechanical stimulus to simulate cortical and cancellous bone remodeling over the first 12 months after final prosthesis delivery. RESULTS The highest increase in cortical bone density was observed at Depth 1.5, whereas the lowest increase was observed at Depth 3.0. In contrast, the highest increase in bone density was observed at Depth 3.0 in the cancellous bone, whereas the lowest increase was observed at Depth 0. The highest peak von Mises stress in the cortical bone occurred at Depth 2.5 (107.24 MPa), while that in the cancellous bone was at Depth 2.5 (34.55 MPa). Notably, the maximum von Mises stress values in the cancellous bone exceeded the natural limit of the bony material, as indicated by the overloading elements observed at the depths of 2.0, 2.5, and 3.0 mm. CONCLUSION Greater bone density apposition is observed with deeper implant placement. An implant depth of more than 1.5 mm exhibited a higher maximum von Mises stress and greater overloading elements.
Collapse
Affiliation(s)
- Pongsakorn Poovarodom
- PhD Student, Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Thailand
| | - Chaiy Rungsiyakull
- Department of Mechanical Engineering, Faculty of Engineering, Chiang Mai University, Thailand
| | - Jarupol Suriyawanakul
- Department of Mechanical Engineering, Faculty of Engineering, Khon Kaen University, Thailand
| | - Qing Li
- School of Aerospace, Mechanical and Mechatronic Engineering, Faculty of Engineering, The University of Sydney, Australia
| | - Keiichi Sasaki
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Japan
| | - Nobuhiro Yoda
- Graduate School of Dentistry, Division of Prosthetic Dentistry, Tohoku University, Japan
| | - Pimduen Rungsiyakull
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Thailand
| |
Collapse
|
19
|
Erdoğan MM, Şimşek T, Ugur L. Using Single Miniplate in Mandibular Angle Fractures: Finite Elements Analysis. J Med Biol Eng 2022. [DOI: 10.1007/s40846-022-00731-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
20
|
Park S, Park J, Kang I, Lee H, Noh G. Effects of assessing the bone remodeling process in biomechanical finite element stability evaluations of dental implants. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 221:106852. [PMID: 35660763 DOI: 10.1016/j.cmpb.2022.106852] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Revised: 04/25/2022] [Accepted: 04/30/2022] [Indexed: 06/15/2023]
Abstract
BACKGROUND AND OBJECTIVE While an accurate assessment of the biomechanical stability of implants is essential in dental prosthesis planning and associated treatment assurance, the bone remodeling process is often ignored in biomechanical studies using finite element (FE) analysis. In this study, we aimed to analyze the significance of assessing the bone remodeling process in FE analysis for evaluating the biomechanical stability of dental implants. We compared the FE results considering the bone remodeling process with FE results simulated using commonly used conditions, with no considerations of the bone remodeling process. METHODS The mathematical model proposed by Komarova et al. was used to calculate cell population dynamics and changes in bone density at a discrete site. The model was implemented in the FE software ABAQUS, using the UMAT subroutine. Three-dimensional FE models were constructed for two types of bone (III and IV) and three values of implant diameter (4.0, 4.5, and 5.0 mm). An average biting force of 50 N in the vertical direction was applied during the bone remodeling process for 150 days. Afterwards, the maximum biting force of 200 N in the 30° oblique direction was applied to evaluate the stability of the implant systems. RESULTS To understand the impact of bone remodeling on the resultant mechanical responses, we focused on peri-implant cancellous bone based on two parameters: apparent density change and microstrain distribution. The bone density decreased by an average of 5.3 % after implantation, and it was the lowest on the 6th day. The average density increases of the peri-implant cancellous bone were 264.4 kgm3 (bone type III) and 220.0 kgm3 (bone type IV) over 150 days. For the bone stability analysis, the maximum principal strain in the peri-implant bone was used to evaluate the bone stability. If the bone remodeling process is ignored, then the bone volume within the fatigue failure range of the microstrain differs significantly from that if the bone remodeling process is considered, i.e., 60 % higher for bone type III and 33.4 % lower for bone type IV than when the bone remodeling process is considered. CONCLUSIONS The FE result without considering the bone remodeling process could be considered a conservative criterion for bone type III. However, in bone type IV, the FE result without considering the bone remodeling process tends to underestimate the risks. The bone remodeling process is more affected by the initial bone quality than the implant diameter.
Collapse
Affiliation(s)
- Soyeon Park
- School of Mechanical Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Jieun Park
- School of Mechanical Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Inyeong Kang
- School of Mechanical Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Hyeonjong Lee
- Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul 03722, South Korea.
| | - Gunwoo Noh
- School of Mechanical Engineering, Korea University, Seoul 02841, Republic of Korea.
| |
Collapse
|
21
|
Wang L, Fu ZH, Hu ZH, Li M, Qiu LH, Gao Z. Biomechanical behaviour of implant prostheses and adjacent teeth according to bone quality: A finite element analysis. Eur J Oral Sci 2022; 130:e12863. [PMID: 35342996 DOI: 10.1111/eos.12863] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Accepted: 02/28/2022] [Indexed: 11/26/2022]
Abstract
The contribution of biomechanical factors in the formation of proximal contact loss has been observed, but there is little research on the mechanisms by which they contribute. Using finite element analysis, this study aimed to analyse the impact of bone quality on the biomechanical behaviour of a dentition consisting of implant prostheses and adjacent teeth. The occlusal load was applied on the implant/tooth crown. In the mesiodistal direction, the adjacent natural tooth mesially to the implant denture had the tendency for mesial movement, while the distal adjacent natural tooth had the tendency for distal movement. For the supporting bone around the mesial adjacent tooth, the maximum/minimum principal stress and strain values on the mesial side of the bone were higher than those on the distal side of the bone. Stress and strain values on the mesial side of the supporting bone around the distal adjacent tooth were lower than those on the distal side. With decreasing bone density, displacements of teeth and the implant denture, principal stresses and equivalent strains on tooth supporting bone increased. Studies on biomechanical behaviours of a tooth-implant dentition may provide a deeper understanding of implant-induced dental adaptive processes such as proximal contact loss.
Collapse
Affiliation(s)
- Lan Wang
- Department of Stomatology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Zhi-Hui Fu
- Department of Stomatology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Zhi-Hui Hu
- School of Electronic Science and Engineering, Xiamen University, Xiamen, China
| | - Min Li
- Department of Stomatology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Li-Hua Qiu
- Department of Oral and Maxillofacial Surgery, Stomatological Hospital of Chongqing Medical University, Chongqing, China
| | - Zhi Gao
- Department of Stomatology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| |
Collapse
|
22
|
Li L, Gao H, Wang C, Ji P, Huang Y, Wang C. Assessment of Customized Alveolar Bone Augmentation Using Titanium Scaffolds vs Polyetheretherketone (PEEK) Scaffolds: A Comparative Study Based on 3D Printing Technology. ACS Biomater Sci Eng 2022; 8:2028-2039. [PMID: 35443132 DOI: 10.1021/acsbiomaterials.2c00060] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Customized alveolar bone augmentation provides sufficient and precisely regenerated bone tissue for subsequent dental implant placement. Although some clinical cases have confirmed the successful use of the patient-specific polyetheretherketone (PEEK) scaffolds, the biomechanical property and osteogenic performance of the patient-specific PEEK scaffolds remain unclear. The objectives of this study were (1) to evaluate the space maintenance capacity and osteogenic performance of the patient-specific PEEK scaffolds for customized alveolar bone augmentation and (2) to compare the biomechanical properties of three-dimensionally printed titanium scaffolds and PEEK scaffolds. Both titanium scaffolds and PEEK scaffolds were designed and manufactured via additive manufacturing technology combined with computer-aided design (CAD). In three-point bending tests, the bending strength of the PEEK scaffold was about 1/3 that of the titanium scaffold. Accordingly, the equivalent strain value of the internal bone graft beneath the PEEK scaffold was about 3 times that beneath the titanium scaffold in finite element analysis, but the maximum deformations of both scaffolds were less than 0.05 mm. Meanwhile, in in vivo experiments, it is demonstrated that both scaffolds have similar space maintenance capacity and bone ingrowth efficiency. In conclusion, patient-specific PEEK scaffolds showed significantly lower biomechanical strength but comparable space maintenance and osteogenic properties to the titanium counterpart. Compared with traditional guided bone regeneration (GBR) surgery, both patient-specific PEEK and titanium scaffolds can achieve excellent osteogenic space maintenance ability. This study provides a preliminary basis for the clinical translation of the nonmetallic barrier membrane in customized alveolar bone augmentation.
Collapse
Affiliation(s)
- Linzhi Li
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, China.,Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, China
| | - Hui Gao
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, China.,Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, China
| | - Chunjuan Wang
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, China.,Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, China
| | - Ping Ji
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, China.,Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, China
| | - Yuanding Huang
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, China.,Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, China
| | - Chao Wang
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, China.,Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| |
Collapse
|
23
|
Simple anisotropic model of Bone Adaptation - SAMBA. J Mech Behav Biomed Mater 2022; 131:105217. [DOI: 10.1016/j.jmbbm.2022.105217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2020] [Revised: 03/26/2022] [Accepted: 04/02/2022] [Indexed: 11/20/2022]
|
24
|
Jafari B, Ashjaee N, Katoozian H, Tahani M. A comparative study of bone remodeling around hydroxyapatite-coated and novel radial functionally graded dental implants using finite element simulation. Med Eng Phys 2022; 102:103775. [DOI: 10.1016/j.medengphy.2022.103775] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Revised: 01/20/2022] [Accepted: 02/09/2022] [Indexed: 11/25/2022]
|
25
|
Choi SM, Choi H, Lee DH, Hong MH. Comparative finite element analysis of mandibular posterior single zirconia and titanium implants: a 3-dimensional finite element analysis. J Adv Prosthodont 2022; 13:396-407. [PMID: 35003555 PMCID: PMC8712109 DOI: 10.4047/jap.2021.13.6.396] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Revised: 11/23/2021] [Accepted: 12/06/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Zirconia has exceptional biocompatibility and good mechanical properties in clinical situations. However, finite element analysis (FEA) studies on the biomechanical stability of two-piece zirconia implant systems are limited. Therefore, the aim of this study was to compare the biomechanical properties of the two-piece zirconia and titanium implants using FEA. MATERIALS AND METHODS Two groups of finite element (FE) models, the zirconia (Zircon) and titanium (Titan) models, were generated for the exam. Oblique (175 N) and vertical (175 N) loads were applied to the FE model generated for FEA simulation, and the stress levels and distributions were investigated. RESULTS In oblique loading, von Mises stress values were the highest in the abutment of the Zircon model. The von Mises stress values of the Titan model for the abutment screw and implant fixture were slightly higher than those of the Zircon model. Minimum principal stress in the cortical bone was higher in the Titan model than Zircon model under oblique and vertical loading. Under both vertical and oblique loads, stress concentrations in the implant components and bone occurred in the same area. Because the material itself has high stiffness and elastic modulus, the Zircon model exhibited a higher von Mises stress value in the abutments than the Titan model, but at a level lower than the fracture strength of the material. CONCLUSION Owing to the good esthetics and stress controllability of the Zircon model, it can be considered for clinical use.
Collapse
Affiliation(s)
- Sung-Min Choi
- Department of Dental Laboratory Science, College of Health Sciences, Catholic University of Pusan, Busan, Republic of Korea
| | - Hyunsuk Choi
- Department of Dentistry and Prosthodontics, Daegu Catholic University School of Medicine, Daegu, Republic of Korea
| | - Du-Hyeong Lee
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| | - Min-Ho Hong
- Department of Dental Laboratory Science, College of Health Sciences, Catholic University of Pusan, Busan, Republic of Korea
| |
Collapse
|
26
|
Bone Stress Evaluation with and without Cortical Bone Using Several Dental Restorative Materials Subjected to Impact Load: A Fully 3D Transient Finite-Element Study. MATERIALS 2021; 14:ma14195801. [PMID: 34640200 PMCID: PMC8510134 DOI: 10.3390/ma14195801] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Revised: 09/18/2021] [Accepted: 10/01/2021] [Indexed: 12/14/2022]
Abstract
Statement of problem. Previous peri-implantitis, peri-implant bone regeneration, or immediate implant placement postextraction may be responsible for the absence of cortical bone. Single crown materials are then relevant when dynamic forces are transferred into bone tissue and, therefore, the presence (or absence) of cortical bone can affect the long-term survival of the implant. Purpose: the purpose of this study is to assess the biomechanical response of dental rehabilitation when selecting different crown materials in models with and without cortical bone. Methods: several crown materials were considered for modeling six types of crown rehabilitation: full metal (MET), metal-ceramic (MCER), metal-composite (MCOM), peek-composite (PKCOM), carbon fiber-composite (FCOM), and carbon fiber-ceramic (FCCER). An impact-load dynamic finite-element analysis was carried out on all the 3D models of crowns mentioned above to assess their mechanical behavior against dynamic excitation. Implant-crown rehabilitation models with and without cortical bone were analyzed to compare how the load-impact actions affect both type of models. Results: numerical simulation results showed important differences in bone tissue stresses. The results show that flexible restorative materials reduce the stress on the bone and would be especially recommendable in the absence of cortical bone. Conclusions: this study demonstrated that more stress is transferred to the bone when stiffer materials (metal and/or ceramic) are used in implant supported rehabilitations; conversely, more flexible materials transfer less stress to the implant connection. Also, in implant-supported rehabilitations, more stress is transferred to the bone by dynamic forces when cortical bone is absent.
Collapse
|
27
|
Lin C, Hu H, Zhu J, Wu Y, Rong Q, Tang Z. Influence of sagittal root positions on the stress distribution around custom-made root-analogue implants: a three-dimensional finite element analysis. BMC Oral Health 2021; 21:443. [PMID: 34521397 PMCID: PMC8438997 DOI: 10.1186/s12903-021-01809-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Accepted: 09/07/2021] [Indexed: 11/18/2022] Open
Abstract
Background Stress concentration may cause bone resorption even lead to the failure of implantation. This study was designed to investigate whether a certain sagittal root position could cause stress concentration around maxillary anterior custom-made root-analogue implants via three-dimensional finite element analysis. Methods The von Mises stresses in the bone around implants in different groups were compared by finite element analysis. Six models were constructed and divided into two groups through Geomagic Studio 2012 software. The smooth group included models of unthreaded custom-made implants in Class I, II or III sagittal root positions. The threaded group included models of reverse buttress-threaded implants in the three positions. The von Mises stress distributions and the range of the stresses under vertical and oblique loads of 100 N were analyzed through ANSYS 16.0 software. Results Stress concentrations around the labial lamella area were more prominent in the Class I position than in the Class II and Class III positions under oblique loading. Under vertical loading, the most obvious stress concentration areas were the labial lamella and palatal apical areas in the Class I and Class III positions, respectively. Stress was relatively distributed in the labial and palatal lamellae in the Class II position. The maximum von Mises stresses in the bone around the custom-made root-analogue implants in this study were lower than around traditional implants reported in the literature. The maximum von Mises stresses in this study were all less than 25 MPa in cortical bone and less than 6 MPa in cancellous bone. Additionally, compared to the smooth group, the threaded group showed lower von Mises stress concentration in the bone around the implants. Conclusions The sagittal root position affected the von Mises stress distribution around custom-made root-analogue implants. There was no certain sagittal root position that could cause excessive stress concentration around the custom-made root-analogue implants. Among the three sagittal root positions, the Class II position would be the most appropriate site for custom-made root-analogue implants.
Collapse
Affiliation(s)
- Chunping Lin
- Department of Periodontology, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, 100081, China
| | - Hongcheng Hu
- Second Dental Center, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, 100101, China
| | - Junxin Zhu
- Second Dental Center, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, 100101, China
| | - Yuwei Wu
- Second Dental Center, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, 100101, China
| | - Qiguo Rong
- Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing, 100871, China.
| | - Zhihui Tang
- Second Dental Center, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, 100101, China.
| |
Collapse
|
28
|
Yesilyurt NG, Tuncdemir AR. An evaluation of the stress effect of different occlusion concepts on hybrid abutment and implant supported monolithic zirconia fixed prosthesis: A finite element analysis. J Adv Prosthodont 2021; 13:216-225. [PMID: 34504673 PMCID: PMC8410301 DOI: 10.4047/jap.2021.13.4.216] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 07/22/2021] [Accepted: 07/27/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The aim of this study is to evaluate the effects of canine guidance occlusion and group function occlusion on the degree of stress to the bone, implants, abutments, and crowns using finite element analysis (FEA). MATERIALS AND METHODS This study included the implant-prosthesis system of a three-unit bridge made of monolithic zirconia and hybrid abutments. Three-dimensional (3D) models of a bone-level implant system and a titanium base abutment were created using the original implant components. Two titanium implants, measuring 4 × 11 mm each, were selected. The loads were applied in two oblique directions of 15° and 30° under two occlusal movement conditions. In the canine guidance condition, loads (100 N) were applied to the canine crown only. In the group function condition, loads were applied to all three teeth. In this loading, a force of 100 N was applied to the canine, and 200-N forces were applied to each premolar. The stress distribution among all the components of the implant-bridge system was assessed using ANSYS SpaceClaim 2020 R2 software and finite element analysis. RESULTS Maximum stress was found in the group function occlusion. The maximum stress increased with an increase in the angle of occlusal force. CONCLUSION The canine guidance occlusion with monolithic zirconia crown materials is promising for implant-supported prostheses in the canine and premolar areas.
Collapse
Affiliation(s)
| | - Ali Riza Tuncdemir
- Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, Konya, Turkey
| |
Collapse
|
29
|
Wu C, Entezari A, Zheng K, Fang J, Zreiqat H, Steven GP, Swain MV, Li Q. A machine learning-based multiscale model to predict bone formation in scaffolds. NATURE COMPUTATIONAL SCIENCE 2021; 1:532-541. [PMID: 38217252 DOI: 10.1038/s43588-021-00115-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 07/19/2021] [Indexed: 01/15/2024]
Abstract
Computational modeling methods combined with non-invasive imaging technologies have exhibited great potential and unique opportunities to model new bone formation in scaffold tissue engineering, offering an effective alternate and viable complement to laborious and time-consuming in vivo studies. However, existing numerical approaches are still highly demanding computationally in such multiscale problems. To tackle this challenge, we propose a machine learning (ML)-based approach to predict bone ingrowth outcomes in bulk tissue scaffolds. The proposed in silico procedure is developed by correlating with a dedicated longitudinal (12-month) animal study on scaffold treatment of a major segmental defect in sheep tibia. Comparison of the ML-based time-dependent prediction of bone ingrowth with the conventional multilevel finite element (FE2) model demonstrates satisfactory accuracy and efficiency. The ML-based modeling approach provides an effective means for predicting in vivo bone tissue regeneration in a subject-specific scaffolding system.
Collapse
Affiliation(s)
- Chi Wu
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, New South Wales, Australia
| | - Ali Entezari
- School of Biomedical Engineering, The University of Sydney, Sydney, New South Wales, Australia
| | - Keke Zheng
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, New South Wales, Australia
| | - Jianguang Fang
- School of Civil and Environmental Engineering, University of Technology Sydney, Sydney, New South Wales, Australia
| | - Hala Zreiqat
- School of Biomedical Engineering, The University of Sydney, Sydney, New South Wales, Australia
| | - Grant P Steven
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, New South Wales, Australia
| | - Michael V Swain
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, New South Wales, Australia
| | - Qing Li
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, New South Wales, Australia.
| |
Collapse
|
30
|
A Parametric Study on a Dental Implant Geometry Influence on Bone Remodelling through a Numerical Algorithm. PROSTHESIS 2021. [DOI: 10.3390/prosthesis3020016] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
To ensure the long-term success of a dental implant, it is imperative to understand how chewing loads are transferred through the implant prosthetic components to the surrounding bone tissue. The stress distribution depends on several factors, such as load type, bone–implant interface, shape and materials of the fixture and quality and quantity of the bone. These aspects are of fundamental importance to ensure implant stability and to evaluate the remodelling capacity of the bone tissue to adapt to its biomechanical environment. A bone remodelling algorithm was formulated by the authors and implemented by means of finite element simulations on four different implants with several design characteristics. Internal bone microstructure and density, apposition/resorption of tissue and implant stability were evaluated over a period of 12 months, showing the influence of the geometry on bone tissue evolution over time. Bone remodelling algorithms may be a useful aid for clinicians to prevent possible implant failures and define an adequate implant prosthetic rehabilitation for each patient. In this work, for the first time, external bone remodelling was numerically predicted over time.
Collapse
|
31
|
Mirulla AI, Pinelli S, Zaffagnini S, Nigrelli V, Ingrassia T, Paolo SD, Bragonzoni L. Numerical simulations on periprosthetic bone remodeling: a systematic review. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 204:106072. [PMID: 33819822 DOI: 10.1016/j.cmpb.2021.106072] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Accepted: 03/22/2021] [Indexed: 06/12/2023]
Abstract
BACKGROUND AND OBJECTIVE The aim of the present study was to review the literature concerning the analysis of periprosthetic bone remodeling through finite element (FE) simulation. METHODS A systematic review was conducted on 9 databases, taking into account a ten-year time period (from 2009 until 2020). The inclusion criteria were: articles published in English, publication date after 2009, full text articles, articles containing the keywords both in the abstract and in the title. The articles were classified through the following parameters: dimensionality of the simulation, modelling of the bone-prosthesis interface, output parameters, type of simulated prosthesis, bone remodeling algorithm. RESULTS Sixty-seven articles were included in the study. Femur and tooth were the most evaluated bone segment (respectively 41.8% and 29.9%). The 55.2% of the evaluated articles used a bonded bone-prosthesis interface, 73% used 3D simulations, 67.2% of the articles (45 articles) evaluate the bone remodeling by the bone density variation. At last, 59.7% of the articles employed algorithms based on a specific remodeling function. CONCLUSIONS Increasing interest in the bone remodeling FE analysis in different bone segments emerged from the review, and heterogeneous solutions were adopted. An optimal balance between computational cost and accuracy is needed to accurately simulate the bone remodeling phenomenon in the post-operative period.
Collapse
Affiliation(s)
- Agostino Igor Mirulla
- Department of Engineering, University of Palermo, Viale delle Scienze Ed.8, 90128 Palermo, Italy; Department of Biomedical and Neurmotor Sciences, University of Bologna, Via G. Pupilli 1, 40136 Bologna, Italy.
| | - Salvatore Pinelli
- Department of Information Engineering, University of Pisa, Pisa, Via G. Caruso 16, 56122 Pisa, Italy
| | - Stefano Zaffagnini
- Department of Biomedical and Neurmotor Sciences, University of Bologna, Via G. Pupilli 1, 40136 Bologna, Italy; 2nd Orthopaedic and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Via G. Pupilli 1, 40136 Bologna, Italy
| | - Vincenzo Nigrelli
- Department of Engineering, University of Palermo, Viale delle Scienze Ed.8, 90128 Palermo, Italy
| | - Tommaso Ingrassia
- Department of Engineering, University of Palermo, Viale delle Scienze Ed.8, 90128 Palermo, Italy
| | - Stefano Di Paolo
- Department of Biomedical and Neurmotor Sciences, University of Bologna, Via G. Pupilli 1, 40136 Bologna, Italy
| | - Laura Bragonzoni
- Department for Life Quality Studies, University of Bologna, Corso d'Augusto 237, 47921 Rimini, Italy
| |
Collapse
|
32
|
Gasik M, Lambert F, Bacevic M. Biomechanical Properties of Bone and Mucosa for Design and Application of Dental Implants. MATERIALS 2021; 14:ma14112845. [PMID: 34073388 PMCID: PMC8199480 DOI: 10.3390/ma14112845] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 05/22/2021] [Accepted: 05/24/2021] [Indexed: 12/20/2022]
Abstract
Dental implants’ success comprises their proper stability and adherence to different oral tissues (integration). The implant is exposed to different mechanical stresses from swallowing, mastication and parafunctions for a normal tooth, leading to the simultaneous mechanical movement and deformation of the whole structure. The knowledge of the mechanical properties of the bone and gingival tissues in normal and pathological conditions is very important for the successful conception of dental implants and for clinical practice to access and prevent potential failures and complications originating from incorrect mechanical factors’ combinations. The challenge is that many reported biomechanical properties of these tissues are substantially scattered. This study carries out a critical analysis of known data on mechanical properties of bone and oral soft tissues, suggests more convenient computation methods incorporating invariant parameters and non-linearity with tissues anisotropy, and applies a consistent use of these properties for in silico design and the application of dental implants. Results show the advantages of this approach in analysis and visualization of stress and strain components with potential translation to dental implantology.
Collapse
Affiliation(s)
- Michael Gasik
- School of Chemical Engineering, Aalto University Foundation, 02150 Espoo, Finland
- Correspondence:
| | - France Lambert
- Dental Biomaterials Research Unit, University of Liege, 4000 Liège, Belgium; (F.L.); (M.B.)
| | - Miljana Bacevic
- Dental Biomaterials Research Unit, University of Liege, 4000 Liège, Belgium; (F.L.); (M.B.)
| |
Collapse
|
33
|
Dantas T, Madeira S, Gasik M, Vaz P, Silva F. Customized Root-Analogue Implants: A Review on Outcomes from Clinical Trials and Case Reports. MATERIALS 2021; 14:ma14092296. [PMID: 33946678 PMCID: PMC8124429 DOI: 10.3390/ma14092296] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 04/22/2021] [Accepted: 04/23/2021] [Indexed: 01/14/2023]
Abstract
(1) It is estimated that 10% of the world’s population will need a dental implant in their lifetime. Despite all the advances in the comprehension of dental implant designs, materials and techniques, traditional implants still have many limitations. Customized root-analogue implants are, therefore, gaining increased interest in dental rehabilitation and are expected to not only preserve more hard and soft tissues but also avoid a second surgery and improve patient overall satisfaction. In this sense, the aim of this review was to collect and analyse the clinical trials and case reports on customized root-analogue implants available in the literature; (2) This review was carried out according to the PRISMA Statement. An electronic database search was performed using five databases: PubMed, Google Scholar, Medline, Science Direct, and Scopus. The following keywords were used for gathering data: custom-made, dental implants, root-analogue, anatomical, customized and tooth-like; (3) 15 articles meeting the inclusion criteria—articles reporting clinical trials, case reports or animal studies and articles with root-analogue implants and articles with totally customized implant geometries—were selected for the qualitative synthesis. The design and manufacturing techniques, implant material and surface treatments were assessed and discussed; (4) The performance of some root-analogue implants with specific features (i.e., macro-retentions) was successful, with no signs of infection, periodontitis nor bleeding during the follow-up periods.
Collapse
Affiliation(s)
- Telma Dantas
- CMEMS (Center for Micro Electro Mechanical Systems), University of Minho, 4800-058 Guimarães, Portugal; (S.M.); (F.S.)
- MIT Portugal Program—School of Engineering, University of Minho, 4800-058 Guimarães, Portugal
- Correspondence:
| | - Sara Madeira
- CMEMS (Center for Micro Electro Mechanical Systems), University of Minho, 4800-058 Guimarães, Portugal; (S.M.); (F.S.)
| | - Michael Gasik
- School of Chemical Engineering, Aalto University Foundation, 02150 Espoo, Finland;
| | - Paula Vaz
- Fixed Prosthodontics, Genetics—Faculty of Dental Medicine, University of Porto, 4200-135 Porto, Portugal;
| | - Filipe Silva
- CMEMS (Center for Micro Electro Mechanical Systems), University of Minho, 4800-058 Guimarães, Portugal; (S.M.); (F.S.)
| |
Collapse
|
34
|
Wu C, Fang J, Entezari A, Sun G, Swain MV, Xu Y, Steven GP, Li Q. A time-dependent mechanobiology-based topology optimization to enhance bone growth in tissue scaffolds. J Biomech 2021; 117:110233. [PMID: 33601086 DOI: 10.1016/j.jbiomech.2021.110233] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 10/05/2020] [Accepted: 01/03/2021] [Indexed: 12/21/2022]
Abstract
Scaffold-based bone tissue engineering has been extensively developed as a potential means to treatment of large bone defects. To enhance the biomechanical performance of porous tissue scaffolds, computational design techniques have gained growing popularity attributable to their compelling efficiency and strong predictive features compared with time-consuming trial-and-error experiments. Nevertheless, the mechanical stimulus necessary for bone regeneration, which characterizes dynamic nature due to continuous variation in the bone-scaffold construct system as a result of bone-ingrowth and scaffold biodegradation, is often neglected. Thus, this study proposes a time-dependent mechanobiology-based topology optimization framework for design of tissue scaffolds, thereby developing an ongoing favorable microenvironment and ensuring a long-term outcome for bone regeneration. For the first time, a level-set based topology optimization algorithm and a time-dependent shape derivative are developed to optimize the scaffold architecture. In this study, a large bone defect in a simulated 2D femur model and a partial defect in a 3D femur model are considered to demonstrate the effectiveness of the proposed design method. The results are compared with those obtained from stiffness-based topology optimization, time-independent design and typical scaffold constructs, showing significant advantages in continuing bone ingrowth outcomes.
Collapse
Affiliation(s)
- Chi Wu
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Jianguang Fang
- School of Civil and Environmental Engineering, University of Technology Sydney, Sydney, NSW 2007, Australia
| | - Ali Entezari
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Guangyong Sun
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Michael V Swain
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Yanan Xu
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Grant P Steven
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Qing Li
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia.
| |
Collapse
|
35
|
Robau-Porrua A, Pérez-Rodríguez Y, Soris-Rodríguez LM, Pérez-Acosta O, González JE. The effect of diameter, length and elastic modulus of a dental implant on stress and strain levels in peri-implant bone: A 3D finite element analysis. Biomed Mater Eng 2020; 30:541-558. [PMID: 31903978 DOI: 10.3233/bme-191073] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
This study investigated the effect of three different parameters of a dental implant on stress and strain values in the peri-implant bone by finite element analysis. In this work, the effect of diameter, length and elastic modulus on the biomechanical behavior of a new dental implant was simulated using the finite element method. A three-dimensional model of a mandible segment corresponding to the premolar region and twelve dental implant models were obtained. Loads in three directions were distributed on the surface of the coronal area of the dental implants. The dental implant models were obtained in the FreeCAD 0.16 software and the simulations were made using the Abaqus/CAE software. In all cases, higher stress concentrations were obtained in the peri-implant cortical bone between 40.6 and 62.8 MPa, while the highest levels of strain were observed in the peri-implant trabecular bone between 0.002544 and 0.003873. In general, the highest von Mises equivalent stress values were observed in the peri-implant cortical bone. However, in this bone, both the maximum von Mises equivalent stress values and the von Mises strain are similar or inferior to those reported in different studies by finite element for other models of dental implants under immediate loading. Maximum von Mises strain values were observed in peri-implant trabecular bone. However, in this bone strains levels were obtained that maintain bone density or increase it. The effect of the three simulated variables (implant diameter, length, and elastic modulus) have a statistically significant influence on the von Mises equivalent stress and in von Mises strain values.
Collapse
Affiliation(s)
- Amanda Robau-Porrua
- Department of Technology of Machinery Construction, Mechanical Engineering Faculty, Technological University of Havana José Antonio Echeverría, Cuba
| | | | - Laura M Soris-Rodríguez
- Department of Technology of Machinery Construction, Mechanical Engineering Faculty, Technological University of Havana José Antonio Echeverría, Cuba
| | | | - Jesús E González
- Department of Ceramic and Metallic Biomaterials, Biomaterials Center, University of Havana, Cuba
| |
Collapse
|
36
|
The interplay between bone healing and remodeling around dental implants. Sci Rep 2020; 10:4335. [PMID: 32152332 PMCID: PMC7063044 DOI: 10.1038/s41598-020-60735-7] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Accepted: 02/12/2020] [Indexed: 01/08/2023] Open
Abstract
Long-term bone healing/adaptation after a dental implant treatment starts with diffusion of mesenchymal stem cells to the wounded region and their subsequent differentiation. The healing phase is followed by the bone-remodeling phase. In this work, a mechano-regulatory cellular differentiation model was used to simulate tissue healing around an immediately loaded dental implant. All tissue types were modeled as poroelastic in the healing phase. Material properties of the healing region were updated after each loading cycle for 30 cycles (days). The tissue distribution in the healed state was then used as the initial condition for the remodeling phase during which regions healed into bone adapt their apparent density with respect to a homeostatic remodeling stimulus. The short- (bone healing) and long-term (bone remodeling) effects of initial implant micromotion during the healing phase were studied. Development of soft tissue was observed both in the coronal region due to high fluid velocity, and on the vertical sides of the healing-gap due to high shear stress. In cases with small implant micromotion, tissue between the implant threads differentiated into bone during the healing phase but resorbed during remodeling. In cases with large implant micromotion, higher percentage of the healing region differentiated into soft tissue resulting in smaller volume of bone tissue available for remodeling. However, the remaining bone region developed higher density bone tissue. It was concluded that an optimal range of initial implant micromotion could be designed for a specific patient in order to achieve the desired long-term functional properties.
Collapse
|
37
|
Shiraishi N, Masumoto H, Takahashi K, Tenkumo T, Anada T, Suzuki O, Ogawa T, Sasaki K. Histomorphometric assessments of peri-implant bone around Ti-Nb-Sn alloy implants with low Young's modulus. Dent Mater J 2020; 39:148-153. [PMID: 31666486 DOI: 10.4012/dmj.2018-376] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Many β-Ti alloys have been developed for, and used in, medical devices because of the corrosion resistance, biocompatibility, and exceptionally low Young's modulus. The aim of the present study was to investigate the histomorphometric aspects of peri-implant bone around Ti-Nb-Sn alloy implants and compare them with those in the case of commercially pure Ti (Ti). Fluorescent morphological observations of ST-2 cells on the substrate were performed and bone morphogenesis around implants in rat femur was evaluated. There was no difference between the cell morphology on Ti and those on the Ti-Nb-Sn alloy during observation for 24 h. A comparison of the Ti-Nb-Sn alloy implant and the Ti implant showed no significant differences between the bone-to-implant contact ratios or the bone fractions. These results suggest that the biological adaptations with Ti-Nb-Sn implants during a healing period are similar to those with Ti. Ti-Nb-Sn is therefore suitable for use in dental implants.
Collapse
Affiliation(s)
- Naru Shiraishi
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Tohoku University.,Division of Dysphagia Rehabilitation, Niigata University Graduate School of Medical and Dental Sciences
| | - Hiroshi Masumoto
- Frontier Research Institute for Interdisciplinary Sciences, Tohoku University
| | - Kenta Takahashi
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Tohoku University
| | - Taichi Tenkumo
- Laboratory for Redox Regulation, Tohoku University Graduate School of Dentistry
| | - Takahisa Anada
- Institute for Materials Chemistry and Engineering, Kyushu University
| | - Osamu Suzuki
- Division of Craniofacial Function Engineering, Tohoku University Graduate School of Dentistry, Tohoku University
| | - Toru Ogawa
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Tohoku University
| | - Keiichi Sasaki
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Tohoku University
| |
Collapse
|
38
|
Ashrafi M, Ghalichi F, Mirzakouchaki B, Arruga A, Doblare M. Finite element comparison of the effect of absorbers' design in the surrounding bone of dental implants. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2020; 36:e3270. [PMID: 31691498 DOI: 10.1002/cnm.3270] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Revised: 09/18/2019] [Accepted: 09/27/2019] [Indexed: 06/10/2023]
Abstract
Despite the high success rate achieved in current dental implantation, there are still important problems to solve like incomplete early osteointegration, bone damage, and long-term implant loosening. Highly compliant stress absorbers are a possible solution to these problems. Although several works examined the stress-strain distribution in bone without and with absorbers to show their favorable results, none of them analyzed their impact on long-term remodeling. Here, we analyze this effect by comparing the evolution of stress and bone mass density without and with different designs of absorbers with those of the healthy tooth. Several finite element models with ABAQUS, corresponding to each design considered, were built to obtain the mechanical conditions in bone and implant. Then a mechanobiological bone remodeling model that considers damage accumulation and its repair during the remodeling process was used to compute the bone density redistribution. This approach allows assessing both the short-term density loss and the relative micromovement between bone and implant. We analyze the stress distributions in both bone and implant as well as the relative micromovement of the implant. We also present the evolution of damage and bone volume fraction. These results show that the addition of absorbers can reduce the stress in the bone around the implant. The obtained results also show that using stress absorbers reduces damage in bone, while increasing the number of absorbers does not necessarily improves damage reduction. We conclude that using implants with a correct design of absorbers prevents damage and stress shielding, reducing implant loosening.
Collapse
Affiliation(s)
- Mehran Ashrafi
- Faculty of Biomedical Engineering, Sahand University of Technology, Sahand New Town, Tabriz, Iran
| | - Farzan Ghalichi
- Faculty of Biomedical Engineering, Sahand University of Technology, Sahand New Town, Tabriz, Iran
| | - Behnam Mirzakouchaki
- Tabriz Dental School, Orthodontic Department, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Alberto Arruga
- Aragón Institute of Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
- Aragón Institute of Health Research (IISA), University of Zaragoza, Zaragoza, Spain
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Spain
| | - Manuel Doblare
- Aragón Institute of Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
- Aragón Institute of Health Research (IISA), University of Zaragoza, Zaragoza, Spain
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Spain
| |
Collapse
|
39
|
Wang X, Zhang T, Yang E, Gong Z, Shen H, Wu H, Zhang D. Biomechanical Analysis of Grafted and Nongrafted Maxillary Sinus Augmentation in the Atrophic Posterior Maxilla with Three-Dimensional Finite Element Method. SCANNING 2020; 2020:8419319. [PMID: 33093935 PMCID: PMC7556061 DOI: 10.1155/2020/8419319] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 09/18/2020] [Accepted: 09/18/2020] [Indexed: 05/12/2023]
Abstract
This study is aimed at determining the optimal sinus augmentation approach considering the poor bone condition in the zone of atrophic posterior maxilla. A series of simplified maxillary segment models varying in residual bone height (RBH) and bone quality were established. A 10 mm standard implant combined with two types of maxillary sinus augmentation methods was applied with the RBH, which was less than 10 mm in the maxilla. The maximal equivalent von Mises (EQV) stress in residual bone was evaluated. Bone quality had an enormous impact on the stress magnitude of supporting bone. Applying sinus augmentation combined with grafts was suitable for stress distribution, and high-stiffness graft performed better than low-stiffness one. For 7 mm and 5 mm atrophic maxilla, nongrafted maxillary sinus augmentation was feasible in D3 bone. Poor bone quality was a negative factor for the implant in the region of atrophic posterior maxilla, which could be improved by grafts. Meanwhile, the choice of maxillary sinus augmentation approaches should be determined by the RBH and quality.
Collapse
Affiliation(s)
- Xuan Wang
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, China
| | - Tianqi Zhang
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, China
| | - Enli Yang
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, China
| | - Zhiyuan Gong
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, China
| | - Hongzhou Shen
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, China
| | - Haiwei Wu
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, China
| | - Dongsheng Zhang
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
- Department of Oral and Maxillofacial Surgery, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, China
| |
Collapse
|
40
|
Three-dimensional finite element analysis of two angled narrow-diameter implant designs for an all-on-4 prosthesis. J Prosthet Dent 2019; 124:477-484. [PMID: 31810614 DOI: 10.1016/j.prosdent.2019.09.015] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 09/25/2019] [Accepted: 09/25/2019] [Indexed: 11/23/2022]
Abstract
STATEMENT OF PROBLEM Although the concept of angulated dental implants has been used for the rehabilitation of the completely edentulous maxilla, its use has yet to be validated with narrow-diameter implants. Proper estimation of narrow-diameter implant dimensions and angulations is essential for the correct use of these implants. PURPOSE The purpose of this 3D finite element analysis study was to compare the stress levels and distributions of 2 narrow-diameter angled implant arrangements supporting a maxillary fixed complete prosthesis. MATERIAL AND METHODS Two commercially available narrow-diameter implants (3.5×11.5 mm, Unitite Prime; 2.9×11.5 mm, Unitite Slim) were compared for their performances under axial and oblique loading (masticatory force: 100 N) in simulated situations of all-on-4 treatment (2 parallel anterior implants perpendicular to the bone crest and 2 posterior implants angled at 30 degrees). An edentulous maxilla model generated from computed tomography and a prosthesis parametric computer-aided design (CAD) model were combined with computational models of implants and prosthetic components to represent implant-supported maxillary fixed complete prostheses. A condition of complete osseointegration was assumed. Peri-implant bone was analyzed by the Mohr-Coulomb criterion. Implants, abutments, and screws were analyzed by the von Mises criterion, and frameworks by the Rankine criterion. RESULTS The 3.5-mm model showed higher axial load values for peri-implant bone, implants, and abutments than the 2.9-mm model. As for oblique load, values were higher for right-sided peri-implant bone, implants, abutments, and frameworks in the 3.5-mm model than in the 2.9-mm model. The 3.5-mm model had a 16% lower risk of peri-implant bone loss for the axial load and 4% for the oblique load. CONCLUSIONS The biomechanical behavior of an angled 2.9-mm implant was comparable with that of a 3.5-mm implant for an all-on-4 prosthesis. However, despite a lower risk of peri-implant bone loss, the 3.5-mm model had higher peak stress on implants and abutments than the 2.9-mm model.
Collapse
|
41
|
Varghese V, Krishnan V, Kumar GS. Comparison of pullout strength of pedicle screws following revision using larger diameter screws. Med Eng Phys 2019; 74:180-185. [DOI: 10.1016/j.medengphy.2019.09.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Revised: 08/06/2019] [Accepted: 09/08/2019] [Indexed: 02/03/2023]
|
42
|
Chen X, Mao B, Zhu Z, Yu J, Lu Y, Zhang Q, Yue L, Yu H. A three-dimensional finite element analysis of mechanical function for 4 removable partial denture designs with 3 framework materials: CoCr, Ti-6Al-4V alloy and PEEK. Sci Rep 2019; 9:13975. [PMID: 31562391 PMCID: PMC6765051 DOI: 10.1038/s41598-019-50363-1] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Accepted: 09/02/2019] [Indexed: 02/05/2023] Open
Abstract
Polyetheretherketone (PEEK) is a new material used for the frameworks of removable partial dentures (RPD). The questions whether the PEEK framework has similar stress distribution on oral tissue and displacement under masticatory forces as titanium alloy (Ti-6Al-4V) or cobalt-chromium alloy (CoCr) remain unclear and worth exploring. A patient's intraoral data were obtained via CBCT and master model scan. Four RPDs were designed by 3Shape dental system, and the models were processed by three-dimensional finite element analysis. Among three materials tested, PEEK has the lowest maximum von Mises stress (VMS) on periodontal ligament (PDL), the greatest maximum VMS on mucosa, the maximum displacement on free-end of framework, and the lowest maximum VMS on framework. Results suggested that PEEK framework has a good protective effect on PDL, suggesting applications for patients with poor periodontal conditions. However, the maximum displacement of the free-end under masticatory force is not conducive for denture stability, along with large stress on the mucosa indicate that PEEK is unsuitable for patients with more loss of posterior teeth with free-end edentulism.
Collapse
Affiliation(s)
- Xin Chen
- Department of Prothesis, West China Hospital of Stomatology, Sichuan University, Chengdu, 610000, China.,the State Key Laboratory of Oral Disease, West China College of Stomatology, Sichuan University, Sichuan, 610041, China
| | - Bochun Mao
- the State Key Laboratory of Oral Disease, West China College of Stomatology, Sichuan University, Sichuan, 610041, China
| | - Zhuoli Zhu
- Department of Prothesis, West China Hospital of Stomatology, Sichuan University, Chengdu, 610000, China.,the State Key Laboratory of Oral Disease, West China College of Stomatology, Sichuan University, Sichuan, 610041, China
| | - Jiayi Yu
- Department of Prothesis, West China Hospital of Stomatology, Sichuan University, Chengdu, 610000, China.,the State Key Laboratory of Oral Disease, West China College of Stomatology, Sichuan University, Sichuan, 610041, China
| | - Yuqing Lu
- Department of Prothesis, West China Hospital of Stomatology, Sichuan University, Chengdu, 610000, China.,the State Key Laboratory of Oral Disease, West China College of Stomatology, Sichuan University, Sichuan, 610041, China
| | - Qianqian Zhang
- Department of Prothesis, West China Hospital of Stomatology, Sichuan University, Chengdu, 610000, China.,the State Key Laboratory of Oral Disease, West China College of Stomatology, Sichuan University, Sichuan, 610041, China
| | - Li Yue
- Department of Prothesis, West China Hospital of Stomatology, Sichuan University, Chengdu, 610000, China.,the State Key Laboratory of Oral Disease, West China College of Stomatology, Sichuan University, Sichuan, 610041, China
| | - Haiyang Yu
- Department of Prothesis, West China Hospital of Stomatology, Sichuan University, Chengdu, 610000, China. .,the State Key Laboratory of Oral Disease, West China College of Stomatology, Sichuan University, Sichuan, 610041, China.
| |
Collapse
|
43
|
Zheng K, Yoda N, Chen J, Liao Z, Zhong J, Koyama S, Peck C, Swain M, Sasaki K, Li Q. Effects of buccal thickness augmentation on bone remodeling after maxillary anterior implantation. Biomech Model Mechanobiol 2019; 19:133-145. [DOI: 10.1007/s10237-019-01200-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2018] [Accepted: 07/06/2019] [Indexed: 12/30/2022]
|
44
|
Kawamura M, Masaki C, Shibata Y, Kondo Y, Mukaibo T, Miyazaki T, Hosokawa R. Pentosidine correlates with nanomechanical properties of human jaw bone. J Mech Behav Biomed Mater 2019; 98:20-25. [PMID: 31176091 DOI: 10.1016/j.jmbbm.2019.06.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Revised: 05/28/2019] [Accepted: 06/03/2019] [Indexed: 01/22/2023]
Abstract
Initial intimate apposition between implant fixtures and host bone at the surgical site is a critical factor for osseointegration of dental implants. The advanced glycation end products accumulated in the jaw bone could lead to potential failure of a dental implant during the initial integration stage, because of the inferior bone mechanical property associated with the abnormal collagen cross-linking at the material level. Here, we demonstrate the lowered creep deformation resistance and reduced dimensional recovery of jaw bone in line with high levels of pentosidine accumulation in the bone matrix which likely correlate with the pentosidine level in blood plasma. Peripheral blood samples and cortical bone samples at the surgical site were obtained from patients scheduled for dental implants in the mandible. The pentosidine levels in blood plasma were assessed. Subsequently, the relative pentosidine levels and the mechanical properties of the jaw bone were quantified by Raman microspectroscopy and nanoindentation, respectively. The nanoindentation tests revealed less creep deformation resistance and reduced time-dependent dimensional recovery of bone samples with the increase in the relative pentosidine level in the bone matrix. Higher tan δ values at the various frequencies during the dynamic indentation tests also suggested that viscoelasticity is associated with the relative intensity of pentosidine in the jaw bone matrix. We found a positive correlation between the pentosidine levels in blood plasma and the bone matrix, which in turn reduced the mechanical property of the jaw bone at the material level. Increased creep and reduced dimensional recovery of the jaw bone may diminish the mechanical interlocking of dental implants during the initial integration stage. Given the likely correlation between the plasma pentosidine level and the mechanical properties of bone, measurement of the plasma pentosidine level could serve as a new index to assess jaw bone matrix quality in advance of implant surgery.
Collapse
Affiliation(s)
- Michihiko Kawamura
- Division of Oral Reconstruction and Rehabilitation, Kyushu Dental University, 2-6-1 Manazuru, Kokurakita-ku, Kitakyushu, Fukuoka, 803-8580, Japan
| | - Chihiro Masaki
- Division of Oral Reconstruction and Rehabilitation, Kyushu Dental University, 2-6-1 Manazuru, Kokurakita-ku, Kitakyushu, Fukuoka, 803-8580, Japan.
| | - Yo Shibata
- Department of Conservative Dentistry, Division of Biomaterials and Engineering, Showa University School of Dentistry, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo, 142-8555, Japan
| | - Yusuke Kondo
- Division of Oral Reconstruction and Rehabilitation, Kyushu Dental University, 2-6-1 Manazuru, Kokurakita-ku, Kitakyushu, Fukuoka, 803-8580, Japan
| | - Taro Mukaibo
- Division of Oral Reconstruction and Rehabilitation, Kyushu Dental University, 2-6-1 Manazuru, Kokurakita-ku, Kitakyushu, Fukuoka, 803-8580, Japan
| | - Takashi Miyazaki
- Department of Conservative Dentistry, Division of Biomaterials and Engineering, Showa University School of Dentistry, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo, 142-8555, Japan
| | - Ryuji Hosokawa
- Division of Oral Reconstruction and Rehabilitation, Kyushu Dental University, 2-6-1 Manazuru, Kokurakita-ku, Kitakyushu, Fukuoka, 803-8580, Japan
| |
Collapse
|
45
|
Chatterjee S, Sarkar S, Kalidindi SR, Basu B. Periprosthetic biomechanical response towards dental implants, with functional gradation, for single/multiple dental loss. J Mech Behav Biomed Mater 2019; 94:249-258. [PMID: 30928669 DOI: 10.1016/j.jmbbm.2019.03.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2019] [Revised: 02/28/2019] [Accepted: 03/02/2019] [Indexed: 01/23/2023]
Abstract
The differences in shape and stiffness of the dental implants with respect to the natural teeth (especially, dental roots) cause a significant alteration of the periprosthetic biomechanical response, which typically leads to bone resorption and ultimately implant loosening. In order to avoid such clinical complications, the implant stiffness needs to be appropriately adapted. In this study, hollow channels were virtually introduced within the designed implant screws for reduction of the overall stiffness of the prototype. In particular, two opposing radial gradients of increasing hollow channel diameters, i.e., outside to inside (Channel 1) and inside to outside (Channel 2) were considered. Two clinical situations of edentulism were addressed in this finite element-based study, and these include a) loss of the first molar, and b) loss of all the three molars. Consequently, two implantation approaches were simulated for multiple teeth loss - individual implantation and implant supported dental bridge. The effects of implant length, approach and channel distribution on the biomechanical response were evaluated in terms of the von Mises stress within the interfacial periprosthetic bone, under normal masticatory loading. The results of our FE analysis clearly reveal significant variation in periprosthetic bone stress between the different implant designs and approaches. An implant screw length of 11 mm with the Channel 2 configuration was found to provide the best biomechanical response. This study also revealed that the implant supported dental bridge approach, which requires lower bone invasion, results in favorable biomechanical response in case of consecutive multiple dental loss.
Collapse
Affiliation(s)
- Subhomoy Chatterjee
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Translational Center on Biomaterials for Orthopaedic and Dental Applications, Indian Institute of Science, Bengaluru 560012, Karnataka, India.
| | - Sulagna Sarkar
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Department of Metallurgical and Material Engineering, Jadavpur University, Kolkata 700032, West Bengal, India.
| | - Surya R Kalidindi
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, North Avenue, Atlanta, GA 30332, USA.
| | - Bikramjit Basu
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Translational Center on Biomaterials for Orthopaedic and Dental Applications, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Centre for BioSystems and Engineering, Indian Institute of Science, Bengaluru 560012, Karnataka, India.
| |
Collapse
|
46
|
Macedo JP, Pereira J, Faria J, Souza JCM, Alves JL, López-López J, Henriques B. Finite element analysis of peri-implant bone volume affected by stresses around Morse taper implants: effects of implant positioning to the bone crest. Comput Methods Biomech Biomed Engin 2019; 21:655-662. [DOI: 10.1080/10255842.2018.1507025] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- J. Paulo Macedo
- School of Dentistry, Division of Oral surgery, Medicine and Implantology, School of Health Sciences (FCS), Fernando Pessoa University (UFP), Porto, Portugal
- Oral Health and Masticatory System Group (Bellvitge Biomedical Research Institute) IDIBELL, University of Barcelona, Barcelona, Spain
| | - Jorge Pereira
- School of Dentistry, Division of Oral surgery, Medicine and Implantology, School of Health Sciences (FCS), Fernando Pessoa University (UFP), Porto, Portugal
- Oral Health and Masticatory System Group (Bellvitge Biomedical Research Institute) IDIBELL, University of Barcelona, Barcelona, Spain
| | - João Faria
- Center for Microelectromechanical Systems (CMEMS-UMinho), University of Minho, Guimarães, Portugal
| | - Júlio C. M. Souza
- Center for Microelectromechanical Systems (CMEMS-UMinho), University of Minho, Guimarães, Portugal
| | - J. Luis Alves
- Center for Microelectromechanical Systems (CMEMS-UMinho), University of Minho, Guimarães, Portugal
| | - José López-López
- Oral Health and Masticatory System Group (Bellvitge Biomedical Research Institute) IDIBELL, University of Barcelona, Barcelona, Spain
| | - Bruno Henriques
- Center for Microelectromechanical Systems (CMEMS-UMinho), University of Minho, Guimarães, Portugal
- Ceramic and Composite Materials Research Group (CERMAT), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| |
Collapse
|
47
|
Sarrafpour B, El-Bacha C, Li Q, Zoellner H. Roles of functional strain and capsule compression on mandibular cyst expansion and cortication. Arch Oral Biol 2018; 98:1-8. [PMID: 30419484 DOI: 10.1016/j.archoralbio.2018.10.035] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 10/09/2018] [Accepted: 10/26/2018] [Indexed: 12/20/2022]
Abstract
OBJECTIVE Cyst expansion in bone involves bone resorption but is often accompanied by adjacent bone formation with cortication. The mechanisms for these two apparently opposite processes remain unclear. From a mechanobiological perspective, functional strain drives bone remodeling, which involves both bone apposition and resorption. In this study, we explore the role of functional strain in cyst growth. DESIGN Using a three-dimensional finite element analysis model of a simulated cyst at the of right first mandibular molar mesial apex, we examined three loading conditions, representing biting on the right molar, left molar and incisors, respectively. Comparison was made with an identical finite element model without the simulated cyst. RESULTS Under all loading conditions, finite element analysis revealed higher strain energy density within the bone lining the cyst compared with the non-cyst model, which is consistent with bone formation and cortication observed clinically. Further analysis demonstrated overall compression of the simulated cyst capsule under all loading conditions.We interpret compression of the capsule as indicating resorption of the adjacent bone surface. CONCLUSIONS We conclude that functional stress results in dominant compression of the soft tissue capsules of bony cysts, contributing to cyst expansion. Also, functional strain becomes elevated in the bone immediately adjacent to the soft tissue cyst capsule, which may drive bone formation and cortication.
Collapse
Affiliation(s)
- Babak Sarrafpour
- The University of Sydney, Discipline of Oral Surgery, Medicine and Diagnostics, School of Dentistry, Faculty of Medicine and Health, Westmead Centre for Oral Health, Westmead Hospital, NSW 2145, Australia.
| | - Charbel El-Bacha
- The University of Sydney, Discipline of Oral Surgery, Medicine and Diagnostics, School of Dentistry, Faculty of Medicine and Health, Westmead Centre for Oral Health, Westmead Hospital, NSW 2145, Australia.
| | - Qing Li
- The University of Sydney, School of Aerospace, Mechanical and Mechatronic Engineering, Sydney, NSW 2006, Australia.
| | - Hans Zoellner
- The University of Sydney, Discipline of Oral Surgery, Medicine and Diagnostics, School of Dentistry, Faculty of Medicine and Health, Westmead Centre for Oral Health, Westmead Hospital, NSW 2145, Australia.
| |
Collapse
|
48
|
The Association Between Buccal Mucosa Thickness and Periimplant Bone Loss and Attachment Loss. IMPLANT DENT 2018; 27:575-581. [DOI: 10.1097/id.0000000000000803] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
49
|
Shahverdi MEI, Nakhodchi S, Sharifi kia D. Fatigue life prediction and stress distribution of straight and angled abutments using numerical techniques. Biomed Phys Eng Express 2018. [DOI: 10.1088/2057-1976/aab18d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
50
|
Marcián P, Wolff J, Horáčková L, Kaiser J, Zikmund T, Borák L. Micro finite element analysis of dental implants under different loading conditions. Comput Biol Med 2018; 96:157-165. [PMID: 29587150 DOI: 10.1016/j.compbiomed.2018.03.012] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Revised: 03/16/2018] [Accepted: 03/16/2018] [Indexed: 11/29/2022]
Abstract
Osseointegration is paramount for the longevity of dental implants and is significantly influenced by biomechanical stimuli. The aim of the present study was to assess the micro-strain and displacement induced by loaded dental implants at different stages of osseointegration using finite element analysis (FEA). Computational models of two mandible segments with different trabecular densities were constructed using microCT data. Three different implant loading directions and two osseointegration stages were considered in the stress-strain analysis of the bone-implant assembly. The bony segments were analyzed using two approaches. The first approach was based on Mechanostat strain intervals and the second approach was based on tensile/compression yield strains. The results of this study revealed that bone surrounding dental implants is critically strained in cases when only a partial osseointegration is present and when an implant is loaded by buccolingual forces. In such cases, implants also encounter high stresses. Displacements of partially-osseointegrated implant are significantly larger than those of fully-osseointegrated implants. It can be concluded that the partial osseointegration is a potential risk in terms of implant longevity.
Collapse
Affiliation(s)
- Petr Marcián
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Faculty of Mechanical Engineering, Brno University of Technology, Brno, Czech Republic.
| | - Jan Wolff
- Department of Oral and Maxillofacial Surgery/Oral Pathology and 3D Innovation Lab, VU University Medical Center, Amsterdam, The Netherlands
| | - Ladislava Horáčková
- Department of Anatomy, Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Jozef Kaiser
- X-ray Micro CT and Nano CT Research Group, CEITEC - Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic
| | - Tomáš Zikmund
- X-ray Micro CT and Nano CT Research Group, CEITEC - Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic
| | - Libor Borák
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Faculty of Mechanical Engineering, Brno University of Technology, Brno, Czech Republic
| |
Collapse
|